Ever-changing market conditions and a rapidly changing IT landscape call for fast and cheap ways to meet software demands. In order to tackle these problems, low-code development platforms (LCDPs) have emerged. These ...Ever-changing market conditions and a rapidly changing IT landscape call for fast and cheap ways to meet software demands. In order to tackle these problems, low-code development platforms (LCDPs) have emerged. These platforms are designed with the idea to limit recurring traditional hand-coding and programming. This article provides a theoretical overview of low-code solutions. The advantages and disadvantages of using LCDP in the creation of automated systems are considered. In conclusion, a conclusion is formulated about the prospects of using low-code technology.展开更多
In distributed cloud storage systems, inevitably there exist multiple node failures at the same time. The existing methods of regenerating codes, including minimum storage regenerating(MSR) codes and minimum bandwidth...In distributed cloud storage systems, inevitably there exist multiple node failures at the same time. The existing methods of regenerating codes, including minimum storage regenerating(MSR) codes and minimum bandwidth regenerating(MBR) codes, are mainly to repair one single or several failed nodes, unable to meet the repair need of distributed cloud storage systems. In this paper, we present locally minimum storage regenerating(LMSR) codes to recover multiple failed nodes at the same time. Specifically, the nodes in distributed cloud storage systems are divided into multiple local groups, and in each local group(4, 2) or(5, 3) MSR codes are constructed. Moreover, the grouping method of storage nodes and the repairing process of failed nodes in local groups are studied. Theoretical analysis shows that LMSR codes can achieve the same storage overhead as MSR codes. Furthermore, we verify by means of simulation that, compared with MSR codes, LMSR codes can reduce the repair bandwidth and disk I/O overhead effectively.展开更多
Digital Communications, in relation to wireless networks, have taken off in recent years due to the expanding need to communicate faster and more efficiently. A popular way to achieve this is by using wireless Multipl...Digital Communications, in relation to wireless networks, have taken off in recent years due to the expanding need to communicate faster and more efficiently. A popular way to achieve this is by using wireless Multiple Input Multiple Output (MIMO) communication systems. MIMO systems utilize Space Time Block Codes (STBC) as one of the leading ways to obtain higher data rates with limited bandwidth and power. With several STBC methods currently available, this paper analyzes simulations using Orthogonal Space Time Block Codes (OSTBC) in Rayleigh fading channels to evaluate the performance of MIMO systems. The selection to use a Rayleigh fading channel as a model for a non-line-of-sight (nLOS) environment is selected to mimic installations where a large number of signal paths and reflections are expected. All simulations are coded, generated and plotted using MATLAB resulting in graphical data representing the bit-error rate (BER) to signal-to-noise ratio (Eb/N<sub>0</sub>) or SNR. Each simulation captures how different configurations of key variables including code rate, diversity and antenna count can impact system performance. Four modulation schemes (BPSK, QPSK, 16-QAM and 64-QAM) are included in each simulation. Conclusive evidence based upon these simulations suggests higher diversity gains were achieved with a greater number of antennas. The most significant factor for increasing system performance was using a lower count of transmit antennas with a higher count of receive antennas.展开更多
By exploiting the structural features of L1C messages,a novel Early Termination( ET) strategy is proposed to speed up the decoding of low-density parity-check( LDPC) codes in the GPS system. The proposed strategy is b...By exploiting the structural features of L1C messages,a novel Early Termination( ET) strategy is proposed to speed up the decoding of low-density parity-check( LDPC) codes in the GPS system. The proposed strategy is based on the cyclic redundancy check( CRC) of the messages in the subframes 2 and 3. The simulation results show that average number of iterations of the proposed strategy is less than that of the standard ET strategy,with nearly no degradation in decoding performance. Besides,the proposed ET strategy can be efficiently implemented in a sequential or parallel manner. Thus,the proposed ET strategy is attractive for practical purposes.展开更多
Multiple antenna wireless systems can provide larger channel capacity and enable spatial diversity to combat fading. In this paper we conduct an investigation into the design of coded space-time system obtained by ser...Multiple antenna wireless systems can provide larger channel capacity and enable spatial diversity to combat fading. In this paper we conduct an investigation into the design of coded space-time system obtained by serially concatenating channel code module and space-time code module with an interleaver in between. As an example, the system is constructed by employing low decoding complexity turbo-SPC (single parity check) code as outer module and linear complex field space-time code as inner module, which achieves full diversity and lossless equivalent channel capacity. Simulation results prove that our designed system performs well and it only loses 0.8 dB from multiple-input multiple-output (MIMO) capacity at BER = 10^-5 in the case of information bit length 6048. Compared with turbo code-based systems, it also has lower error floor.展开更多
The technology of passive safety is the current trend among safety systems in nuclear power plant. Pas- sive residual heat removal system (PRHRS), a major part of passive safety systems of Chinese advanced PWR, is a n...The technology of passive safety is the current trend among safety systems in nuclear power plant. Pas- sive residual heat removal system (PRHRS), a major part of passive safety systems of Chinese advanced PWR, is a novel design with three-fold natural circulation. On the basis of reasonable physics and mathematics models, MI- TAP-PRHRS code was developed to analyze steady and transient characteristics of the PRHRS. The calculation and analysis show that the code simulates steady characteristics of the PRHRS very well, and it is able to simulate tran- sient characteristics of all startup modes of the PRHRS. However, the quantitative description is poor during the ini- tial stages of the transition process when water hammer occurs.展开更多
In Systems Biology, system identification, which infers regulatory network in genetic system and metabolic pathways using experimentally observed time-course data, is one of the hottest issues. The efficient numerical...In Systems Biology, system identification, which infers regulatory network in genetic system and metabolic pathways using experimentally observed time-course data, is one of the hottest issues. The efficient numerical optimization algorithm to estimate more than 100 real-coded parameters should be developed for this purpose. New real-coded genetic algorithm (RCGA), the combination of AREX (adaptive real-coded ensemble crossover) with JGG (just generation gap), have applied to the inference of genetic interactions involving more than 100 parameters related to the interactions with using experimentally observed time-course data. Compared with conventional RCGA, the combination of UNDX (unimodal normal distribution crossover) with MGG (minimal generation gap), new algorithm has shown the superiority with improving early convergence in the first stage of search and suppressing evolutionary stagnation in the last stage of search.展开更多
A new space-time(ST)code design is proposed based on the design criteria of space-time codes,which is applied to the MIMO systems with fewer receive antennas than transmit antennas.The space-time codes,referred to as ...A new space-time(ST)code design is proposed based on the design criteria of space-time codes,which is applied to the MIMO systems with fewer receive antennas than transmit antennas.The space-time codes,referred to as full diversity lossless capacity(FDLLC)ST code,achieve full transmit diversity and lossless equivalent channel capacity for ST precoded systems.Combined FDLLC-ST codes with channel codes,ST bit interleaved coded modulation(ST-BICM)system is constructed and an iterative detector/decoder is employed at the receiver.Simulations are presented.It is proved that the proposed design has good performance compared with other ST precoded MIMO systems.展开更多
A new concatenated code of RS(255,239)+BCH(2 040,1 930) code to be suitable for WDM optical transmission systems is proposed. The simulation results show that this new concatenated code, compared with the RS(255,239)+...A new concatenated code of RS(255,239)+BCH(2 040,1 930) code to be suitable for WDM optical transmission systems is proposed. The simulation results show that this new concatenated code, compared with the RS(255,239)+CSOC(k0/n0=6/7, J=8) code in ITU-T G.75.1, has a lower redundancy and better error-correction performance, furthermore, its net coding gain(NCG) is respectively 0.46 dB, 0.43 dB more than that of RS(255,239)+CSOC(k0/n0 =6/7, J=8) code and BCH(3 860,3 824)+BCH(2 040,1 930) code in ITU-T G.75.1 at the third iteration for the bit error rate(BER) of 10-12. Therefore, the new super forward error correction(Super-FEC) concatenated code can be better used in ultra long-haul, ultra large-capacity and ultra high-speed WDM optical communication systems.展开更多
A new segmented correlating decoder of synchronous optical CDMA using modified prime sequence codes is proposed. The performance of the proposed system is analyzed under the assumption of Poisson shot noise model for ...A new segmented correlating decoder of synchronous optical CDMA using modified prime sequence codes is proposed. The performance of the proposed system is analyzed under the assumption of Poisson shot noise model for the receiver photodetector. The decoder technique is shown to be more effective to improve the bit error probability performance than the method using an optical hard-limiter.展开更多
Error codes induced by M-ary modulation and modulation selection in network-based control systems are studied.It is the first time the issue of error codes induced by M-ary modulation is addressed in control field.In ...Error codes induced by M-ary modulation and modulation selection in network-based control systems are studied.It is the first time the issue of error codes induced by M-ary modulation is addressed in control field.In network-based control systems,error codes induced by noisy channel can significantly decrease the quality of control.To solve this problem,the network-based control system with delay and noisy channel is firstly modeled as an asynchronous dynamic system(ADS).Secondly,conditions of packet with error codes(PEC)loss rate by using M-ary modulation are obtained based on dynamic output feedback scheme.Thirdly,more importantly,the selection principle of M-ary modulation is proposed according to the measured signal-to-noise ratio(SNR)and conditions of PEC loss rate.Finally,system stability is analyzed and controller is designed through Lyapunov function and linear matrix inequality(LMI)scheme,and numerical simulations are made to demonstrate the effectiveness of the proposed scheme.展开更多
In this paper, the main objective is to identify the parameters of motors, which includes a brushless direct current (BLDC) motor and an induction motor. The motor systems are dynamically formulated by the mechanical ...In this paper, the main objective is to identify the parameters of motors, which includes a brushless direct current (BLDC) motor and an induction motor. The motor systems are dynamically formulated by the mechanical and electrical equations. The real-coded genetic algorithm (RGA) is adopted to identify all parameters of motors, and the standard genetic algorithm (SRGA) and various adaptive genetic algorithm (ARGAs) are compared in the rotational angular speeds and fitness values, which are the inverse of square differences of angular speeds. From numerical simulations and experimental results, it is found that the SRGA and ARGA are feasible, the ARGA can effectively solve the problems with slow convergent speed and premature phenomenon, and is more accurate in identifying system’s parameters than the SRGA. From the comparisons of the ARGAs in identifying parameters of motors, the best ARGA method is obtained and could be applied to any other mechatronic systems.展开更多
Previous analytical results on flow splitting are generalized to consider multiple boiling channels systems. The analysis is consistent with the approximations usually adopted in the use of systems codes (like RELAP5 ...Previous analytical results on flow splitting are generalized to consider multiple boiling channels systems. The analysis is consistent with the approximations usually adopted in the use of systems codes (like RELAP5 and TRACE5, among others) commonly applied to perform safety analyses of nuclear power plants. The problem is related to multiple, identical, parallel boiling channels, connected through common plena. A theoretical model limited in scope explains this flow splitting without reversal. The unified analysis performed and the confirmatory computational results found are summarized in this paper. New maps showing the zones where this behavior is predicted are also shown considering again twin pipes. Multiple pipe systems have been found not easily amenable for analytical analysis when dealing with more than four parallel pipes. However, the particular splitting found (flow along N pipes dividing in one standalone pipe flow plus N -1 identical pipe flows) has been verified up to fourteen pipes, involving calculations in systems with even and odd number of pipes using the RELAP5 systems thermal-hydraulics code.展开更多
Although there are appropriate stipulations for the chattel guarantees in the law of China, this guarantee system could not adapt to the request of economy's development because of the following reasons: the scope...Although there are appropriate stipulations for the chattel guarantees in the law of China, this guarantee system could not adapt to the request of economy's development because of the following reasons: the scope of chattel guarantees is narrow according to relevant stipulations; the transaction cost of the chattel is high; mortgage registration of chattel is in a mess; lack of efficiently executive guarantee system, etc. To counter the problems existing in the present Chinese chattel guarantee system, in this article, the author proposed some corresponding suggestions and countermeasures, hoping to perfect the chattel guarantee system in China.展开更多
The paper presents a computer code system 'SRDAAR- QNPP' for the real-time dose as-sessment of an accident release for Qinshan Nuclear Power Plant. It includes three parts:thereal-time data acquisition system,...The paper presents a computer code system 'SRDAAR- QNPP' for the real-time dose as-sessment of an accident release for Qinshan Nuclear Power Plant. It includes three parts:thereal-time data acquisition system, assessment computer. and the assessment operating code system. InSRDAAR-QNPP, the wind field of the surface and the lower levels are determined hourly by using amass consistent three-dimension diasnosis model with the topographic following coordinate system.A Lagrangin Puff model under changing meteorological condition is adopted for atmosphericdispersion, the correction for dry and wet depositions. physical decay and partial plume penetrationof the top inversion and the deviation of plume axis caused by complex terrain have been taken in-to account. The calculation domain areas include three square grid areas with the sideline 10 km, 40krn and 160 km and a grid interval 0.5 km, 2.0 km, 8.0 km respectively. Three exposure pathwaysare taken into account:the external exposure from immersion cloud and passing puff, the internalexposure from inhalation and the external exposure from contaminated ground. This system is ableto provide the results of concentration and dose distributions within 10 minutes after the data havebeen inputed.展开更多
Power control is an important technique in WCDMA mobile systems for both increasing system capacity and guaranteeing the required QoS (time delay and wireless link transmission quality) of multimedia services. The opt...Power control is an important technique in WCDMA mobile systems for both increasing system capacity and guaranteeing the required QoS (time delay and wireless link transmission quality) of multimedia services. The optimum power control for narrow band CDMA cellular systems is a problem of single threshold optimization. Because these systems have only one type of traffic and have the same QoS requirement. However, WCDMA mobile system should provide multimedia services and different types of traffic have different QoS requirements. Thus, the power control in WCDMA mobile systems isn't a problem of single threshold optimizing, but turns into the optimizing problem of multi-threshold. We analyze the power control problem in WCDMA cellular mobile systems and propose the optimum transmitter power control algorithm. Three criteria to optimize transmitter power levels of multi-thresholds based on grading the priority orders of multimedia services are proposed. Simulation results show that the proposed algorithms are more effective than conventional algorithms and can provide better performance for WCDMA cellular mobile systems.展开更多
Clinical laboratory tests are basic elements that support healthcare tasks such as disease detection, diagnosis and monitoring of response to treatments. Current laboratory information systems focus on the patient dat...Clinical laboratory tests are basic elements that support healthcare tasks such as disease detection, diagnosis and monitoring of response to treatments. Current laboratory information systems focus on the patient database, tests and results, with multiple modules available, connecting with the various analytical systems or work areas. However laboratory information systems functioned as “islands of information”, because their design was fundamentally inward-looking and disconnected from other healthcare computer applications. Actually, the Electronic Health Register (EHR) is considered by clinicians as a tool with great potential healthcare benefits. The EHR, in the sense of a unique and complete record of a patient’s healthcare and state of health, regardless of the healthcare level used, is a real attempt to eliminate these “islands of information” and need modules to act as “bridges” with the laboratory information systems. This type of module, which in generic terms may be referred to as a laboratory test request module, has become an essential feature of the EHR. These modules need to use a laboratory coding system as a common language for exchanging information, ensuring that tests and results are unequivocally identified. The development of the laboratory test request module requires the commitment of professionals and political authorities, being necessary time for their design and an adequate pilot phase. The laboratory professionals have to assume a leadership role in the whole process of design, development and implementation of these modules, integrating in the equipment of information technologies of healthcare providers. In our manuscript we review the elements that may prove electronic systems for requesting clinical laboratory test into digital clinical records and the key elements to move from theory to practice.展开更多
This paper considers the case of smart antennas and multiple inputs multiple outputs (MIMO) systems, suited for the radio access of 3G mobile communications, involving two-dimensional spatio-temporal signal processing...This paper considers the case of smart antennas and multiple inputs multiple outputs (MIMO) systems, suited for the radio access of 3G mobile communications, involving two-dimensional spatio-temporal signal processing and two-dwell procedures. The main novelty of our work is twofold: first, a two-dwell acquisition technique is here performed to save the mean acquisition time versus one-dwell acquisition techniques;sec-ond, the searching procedure is driven from the estimates of the local signal-to-interference-plus-noise ratio, reducing again the mean acquisition time. Some examples of application to the detection of 3G communication signals in typical mobile scenarios are provided and we have verified the effectiveness of the analyzed spatio-temporal two-dwell procedures. The presented technique seems to constitute a promising tool for analytic setting of near optimum spatio-temporal acquisition testing procedures based on serial search/veri-fication modes.展开更多
文摘Ever-changing market conditions and a rapidly changing IT landscape call for fast and cheap ways to meet software demands. In order to tackle these problems, low-code development platforms (LCDPs) have emerged. These platforms are designed with the idea to limit recurring traditional hand-coding and programming. This article provides a theoretical overview of low-code solutions. The advantages and disadvantages of using LCDP in the creation of automated systems are considered. In conclusion, a conclusion is formulated about the prospects of using low-code technology.
基金supported in part by the National Natural Science Foundation of China (61640006, 61572188)the Natural Science Foundation of Shaanxi Province, China (2015JM6307, 2016JQ6011)the project of science and technology of Xi’an City (2017088CG/RC051(CADX002))
文摘In distributed cloud storage systems, inevitably there exist multiple node failures at the same time. The existing methods of regenerating codes, including minimum storage regenerating(MSR) codes and minimum bandwidth regenerating(MBR) codes, are mainly to repair one single or several failed nodes, unable to meet the repair need of distributed cloud storage systems. In this paper, we present locally minimum storage regenerating(LMSR) codes to recover multiple failed nodes at the same time. Specifically, the nodes in distributed cloud storage systems are divided into multiple local groups, and in each local group(4, 2) or(5, 3) MSR codes are constructed. Moreover, the grouping method of storage nodes and the repairing process of failed nodes in local groups are studied. Theoretical analysis shows that LMSR codes can achieve the same storage overhead as MSR codes. Furthermore, we verify by means of simulation that, compared with MSR codes, LMSR codes can reduce the repair bandwidth and disk I/O overhead effectively.
文摘Digital Communications, in relation to wireless networks, have taken off in recent years due to the expanding need to communicate faster and more efficiently. A popular way to achieve this is by using wireless Multiple Input Multiple Output (MIMO) communication systems. MIMO systems utilize Space Time Block Codes (STBC) as one of the leading ways to obtain higher data rates with limited bandwidth and power. With several STBC methods currently available, this paper analyzes simulations using Orthogonal Space Time Block Codes (OSTBC) in Rayleigh fading channels to evaluate the performance of MIMO systems. The selection to use a Rayleigh fading channel as a model for a non-line-of-sight (nLOS) environment is selected to mimic installations where a large number of signal paths and reflections are expected. All simulations are coded, generated and plotted using MATLAB resulting in graphical data representing the bit-error rate (BER) to signal-to-noise ratio (Eb/N<sub>0</sub>) or SNR. Each simulation captures how different configurations of key variables including code rate, diversity and antenna count can impact system performance. Four modulation schemes (BPSK, QPSK, 16-QAM and 64-QAM) are included in each simulation. Conclusive evidence based upon these simulations suggests higher diversity gains were achieved with a greater number of antennas. The most significant factor for increasing system performance was using a lower count of transmit antennas with a higher count of receive antennas.
基金Sponsored by the National Natural Science Foundation of China(Grant No.61271423)
文摘By exploiting the structural features of L1C messages,a novel Early Termination( ET) strategy is proposed to speed up the decoding of low-density parity-check( LDPC) codes in the GPS system. The proposed strategy is based on the cyclic redundancy check( CRC) of the messages in the subframes 2 and 3. The simulation results show that average number of iterations of the proposed strategy is less than that of the standard ET strategy,with nearly no degradation in decoding performance. Besides,the proposed ET strategy can be efficiently implemented in a sequential or parallel manner. Thus,the proposed ET strategy is attractive for practical purposes.
基金supported by the National Natural Science Foundation of China (Grant Nos.60332030, 60572157), and the National High-TechnologY Research and Development of China (Grant No.863-2003AA123310)
文摘Multiple antenna wireless systems can provide larger channel capacity and enable spatial diversity to combat fading. In this paper we conduct an investigation into the design of coded space-time system obtained by serially concatenating channel code module and space-time code module with an interleaver in between. As an example, the system is constructed by employing low decoding complexity turbo-SPC (single parity check) code as outer module and linear complex field space-time code as inner module, which achieves full diversity and lossless equivalent channel capacity. Simulation results prove that our designed system performs well and it only loses 0.8 dB from multiple-input multiple-output (MIMO) capacity at BER = 10^-5 in the case of information bit length 6048. Compared with turbo code-based systems, it also has lower error floor.
文摘The technology of passive safety is the current trend among safety systems in nuclear power plant. Pas- sive residual heat removal system (PRHRS), a major part of passive safety systems of Chinese advanced PWR, is a novel design with three-fold natural circulation. On the basis of reasonable physics and mathematics models, MI- TAP-PRHRS code was developed to analyze steady and transient characteristics of the PRHRS. The calculation and analysis show that the code simulates steady characteristics of the PRHRS very well, and it is able to simulate tran- sient characteristics of all startup modes of the PRHRS. However, the quantitative description is poor during the ini- tial stages of the transition process when water hammer occurs.
文摘In Systems Biology, system identification, which infers regulatory network in genetic system and metabolic pathways using experimentally observed time-course data, is one of the hottest issues. The efficient numerical optimization algorithm to estimate more than 100 real-coded parameters should be developed for this purpose. New real-coded genetic algorithm (RCGA), the combination of AREX (adaptive real-coded ensemble crossover) with JGG (just generation gap), have applied to the inference of genetic interactions involving more than 100 parameters related to the interactions with using experimentally observed time-course data. Compared with conventional RCGA, the combination of UNDX (unimodal normal distribution crossover) with MGG (minimal generation gap), new algorithm has shown the superiority with improving early convergence in the first stage of search and suppressing evolutionary stagnation in the last stage of search.
基金Sponsored by the National Natural Science Foundation of China (Grant No. 60332030, 60572157)National High Technology Research and Development of China (Grant No. 2003AA123310)
文摘A new space-time(ST)code design is proposed based on the design criteria of space-time codes,which is applied to the MIMO systems with fewer receive antennas than transmit antennas.The space-time codes,referred to as full diversity lossless capacity(FDLLC)ST code,achieve full transmit diversity and lossless equivalent channel capacity for ST precoded systems.Combined FDLLC-ST codes with channel codes,ST bit interleaved coded modulation(ST-BICM)system is constructed and an iterative detector/decoder is employed at the receiver.Simulations are presented.It is proved that the proposed design has good performance compared with other ST precoded MIMO systems.
基金National High Technology Development Program(863) of China (2005AA123730) Natural Science Foundation of Chongqing University of Posts & Telecommunications(A2006 -53)
文摘A new concatenated code of RS(255,239)+BCH(2 040,1 930) code to be suitable for WDM optical transmission systems is proposed. The simulation results show that this new concatenated code, compared with the RS(255,239)+CSOC(k0/n0=6/7, J=8) code in ITU-T G.75.1, has a lower redundancy and better error-correction performance, furthermore, its net coding gain(NCG) is respectively 0.46 dB, 0.43 dB more than that of RS(255,239)+CSOC(k0/n0 =6/7, J=8) code and BCH(3 860,3 824)+BCH(2 040,1 930) code in ITU-T G.75.1 at the third iteration for the bit error rate(BER) of 10-12. Therefore, the new super forward error correction(Super-FEC) concatenated code can be better used in ultra long-haul, ultra large-capacity and ultra high-speed WDM optical communication systems.
文摘A new segmented correlating decoder of synchronous optical CDMA using modified prime sequence codes is proposed. The performance of the proposed system is analyzed under the assumption of Poisson shot noise model for the receiver photodetector. The decoder technique is shown to be more effective to improve the bit error probability performance than the method using an optical hard-limiter.
基金Project(61172022) supported by the National Natural Science Foundation of ChinaProject(GDW20151100010) supported by the State Administration of Foreign Experts Affairs of China
文摘Error codes induced by M-ary modulation and modulation selection in network-based control systems are studied.It is the first time the issue of error codes induced by M-ary modulation is addressed in control field.In network-based control systems,error codes induced by noisy channel can significantly decrease the quality of control.To solve this problem,the network-based control system with delay and noisy channel is firstly modeled as an asynchronous dynamic system(ADS).Secondly,conditions of packet with error codes(PEC)loss rate by using M-ary modulation are obtained based on dynamic output feedback scheme.Thirdly,more importantly,the selection principle of M-ary modulation is proposed according to the measured signal-to-noise ratio(SNR)and conditions of PEC loss rate.Finally,system stability is analyzed and controller is designed through Lyapunov function and linear matrix inequality(LMI)scheme,and numerical simulations are made to demonstrate the effectiveness of the proposed scheme.
文摘In this paper, the main objective is to identify the parameters of motors, which includes a brushless direct current (BLDC) motor and an induction motor. The motor systems are dynamically formulated by the mechanical and electrical equations. The real-coded genetic algorithm (RGA) is adopted to identify all parameters of motors, and the standard genetic algorithm (SRGA) and various adaptive genetic algorithm (ARGAs) are compared in the rotational angular speeds and fitness values, which are the inverse of square differences of angular speeds. From numerical simulations and experimental results, it is found that the SRGA and ARGA are feasible, the ARGA can effectively solve the problems with slow convergent speed and premature phenomenon, and is more accurate in identifying system’s parameters than the SRGA. From the comparisons of the ARGAs in identifying parameters of motors, the best ARGA method is obtained and could be applied to any other mechatronic systems.
文摘Previous analytical results on flow splitting are generalized to consider multiple boiling channels systems. The analysis is consistent with the approximations usually adopted in the use of systems codes (like RELAP5 and TRACE5, among others) commonly applied to perform safety analyses of nuclear power plants. The problem is related to multiple, identical, parallel boiling channels, connected through common plena. A theoretical model limited in scope explains this flow splitting without reversal. The unified analysis performed and the confirmatory computational results found are summarized in this paper. New maps showing the zones where this behavior is predicted are also shown considering again twin pipes. Multiple pipe systems have been found not easily amenable for analytical analysis when dealing with more than four parallel pipes. However, the particular splitting found (flow along N pipes dividing in one standalone pipe flow plus N -1 identical pipe flows) has been verified up to fourteen pipes, involving calculations in systems with even and odd number of pipes using the RELAP5 systems thermal-hydraulics code.
文摘Although there are appropriate stipulations for the chattel guarantees in the law of China, this guarantee system could not adapt to the request of economy's development because of the following reasons: the scope of chattel guarantees is narrow according to relevant stipulations; the transaction cost of the chattel is high; mortgage registration of chattel is in a mess; lack of efficiently executive guarantee system, etc. To counter the problems existing in the present Chinese chattel guarantee system, in this article, the author proposed some corresponding suggestions and countermeasures, hoping to perfect the chattel guarantee system in China.
文摘The paper presents a computer code system 'SRDAAR- QNPP' for the real-time dose as-sessment of an accident release for Qinshan Nuclear Power Plant. It includes three parts:thereal-time data acquisition system, assessment computer. and the assessment operating code system. InSRDAAR-QNPP, the wind field of the surface and the lower levels are determined hourly by using amass consistent three-dimension diasnosis model with the topographic following coordinate system.A Lagrangin Puff model under changing meteorological condition is adopted for atmosphericdispersion, the correction for dry and wet depositions. physical decay and partial plume penetrationof the top inversion and the deviation of plume axis caused by complex terrain have been taken in-to account. The calculation domain areas include three square grid areas with the sideline 10 km, 40krn and 160 km and a grid interval 0.5 km, 2.0 km, 8.0 km respectively. Three exposure pathwaysare taken into account:the external exposure from immersion cloud and passing puff, the internalexposure from inhalation and the external exposure from contaminated ground. This system is ableto provide the results of concentration and dose distributions within 10 minutes after the data havebeen inputed.
文摘Power control is an important technique in WCDMA mobile systems for both increasing system capacity and guaranteeing the required QoS (time delay and wireless link transmission quality) of multimedia services. The optimum power control for narrow band CDMA cellular systems is a problem of single threshold optimization. Because these systems have only one type of traffic and have the same QoS requirement. However, WCDMA mobile system should provide multimedia services and different types of traffic have different QoS requirements. Thus, the power control in WCDMA mobile systems isn't a problem of single threshold optimizing, but turns into the optimizing problem of multi-threshold. We analyze the power control problem in WCDMA cellular mobile systems and propose the optimum transmitter power control algorithm. Three criteria to optimize transmitter power levels of multi-thresholds based on grading the priority orders of multimedia services are proposed. Simulation results show that the proposed algorithms are more effective than conventional algorithms and can provide better performance for WCDMA cellular mobile systems.
文摘Clinical laboratory tests are basic elements that support healthcare tasks such as disease detection, diagnosis and monitoring of response to treatments. Current laboratory information systems focus on the patient database, tests and results, with multiple modules available, connecting with the various analytical systems or work areas. However laboratory information systems functioned as “islands of information”, because their design was fundamentally inward-looking and disconnected from other healthcare computer applications. Actually, the Electronic Health Register (EHR) is considered by clinicians as a tool with great potential healthcare benefits. The EHR, in the sense of a unique and complete record of a patient’s healthcare and state of health, regardless of the healthcare level used, is a real attempt to eliminate these “islands of information” and need modules to act as “bridges” with the laboratory information systems. This type of module, which in generic terms may be referred to as a laboratory test request module, has become an essential feature of the EHR. These modules need to use a laboratory coding system as a common language for exchanging information, ensuring that tests and results are unequivocally identified. The development of the laboratory test request module requires the commitment of professionals and political authorities, being necessary time for their design and an adequate pilot phase. The laboratory professionals have to assume a leadership role in the whole process of design, development and implementation of these modules, integrating in the equipment of information technologies of healthcare providers. In our manuscript we review the elements that may prove electronic systems for requesting clinical laboratory test into digital clinical records and the key elements to move from theory to practice.
文摘This paper considers the case of smart antennas and multiple inputs multiple outputs (MIMO) systems, suited for the radio access of 3G mobile communications, involving two-dimensional spatio-temporal signal processing and two-dwell procedures. The main novelty of our work is twofold: first, a two-dwell acquisition technique is here performed to save the mean acquisition time versus one-dwell acquisition techniques;sec-ond, the searching procedure is driven from the estimates of the local signal-to-interference-plus-noise ratio, reducing again the mean acquisition time. Some examples of application to the detection of 3G communication signals in typical mobile scenarios are provided and we have verified the effectiveness of the analyzed spatio-temporal two-dwell procedures. The presented technique seems to constitute a promising tool for analytic setting of near optimum spatio-temporal acquisition testing procedures based on serial search/veri-fication modes.