Objectives: There is a high rate of sudden death in epilepsy patients, part of which is sudden cardiac death. By investigating ECG T wave alternans and Q-T dispersion changes of epilepsy patients, we may predict the p...Objectives: There is a high rate of sudden death in epilepsy patients, part of which is sudden cardiac death. By investigating ECG T wave alternans and Q-T dispersion changes of epilepsy patients, we may predict the possibility of the occurrence of sudden death and provide basis for clinical prevention. Methods: Selecting 587 cases of epilepsy patients as the study group, 672 same period cases of healthy persons as the control group;Analyzing the effect of epilepsy on ECG T wave alternans and Q-T dispersion with the standard 12 lead ECG. Results: The study group had a significantly prolonged Q-T dispersion and an increased incidence of T wave alternans than that of the control group;Compared with other seizure types, tonic clonic seizure and absence seizure had a significantly prolonged Q-T dispersion and an increased occurrence rate of T wave alternans. Conclusions: Epilepsy patients ECG T wave alternans and Q-T dispersion has higher abnormal rate, and are prone to sudden cardiac death;Routine ECG(RECG) T wave alternans and Q-T dispersion changes can provide guidance for clinical prevention of sudden unexpected death in epilepsy (SUDEP).展开更多
T-wave alternans (TWA), consisting in an alternation of the electrocardiographic (ECG) repolarization segment (T-wave), is a promising index of the risk of sudden cardiac death. By definition, it is characterized by a...T-wave alternans (TWA), consisting in an alternation of the electrocardiographic (ECG) repolarization segment (T-wave), is a promising index of the risk of sudden cardiac death. By definition, it is characterized by a frequency component, termed fTWA, that matches half heart rate. The heart-rate adaptive match filter (AMF) based method is a technique for automatic TWA identification from the digital ECG. Aim of the present study was to provide a complete technical description of the filter able to explain its methodological principles. The AMF is usually realized as a 6th order Butterworth filter with a narrow (0.12 Hz) passing band centered in fTWA. It is applied in a bidirectional fashion, so that final filtering order is 12. While extracting the TWA component, the AMF simultaneously filters out every ECG component including noise and artefacts, and thus results are very robust. Goodness of the technique was tested using 8 synthetic ECG tracings corrupted by typical noisy factors, such as white random noise, baseline wanderings, heart-rate variability, and others. Six ECG tracings were affected by 100 μV TWA, whereas two were not. Results indicate that the AMF-based method is able to prevent false-positive and false-negative detections and, thus, represents a useful tool for a reliable TWA identification.展开更多
Presently T-wave alternans (TWA) has become a clinical index of non-invasive diagnosis for heart sudden death prediction, and detecting T-wave alternate accurately is particularly important. This paper introduces an a...Presently T-wave alternans (TWA) has become a clinical index of non-invasive diagnosis for heart sudden death prediction, and detecting T-wave alternate accurately is particularly important. This paper introduces an algorithm for detecting TWA using Poincare mapping method which is a technique for nonlinear dynamic systems to display periodic behavior. Sample series of beat to beat cycles were selected to prepare Poincare mapping method. Vector Angle Index (VAI), which is the mean of the difference between θi (the angle between the line connecting the i point to the origin and the X axis) and 45 degrees was used to present the presence or absence of TWA. The value of 0.9 rad ≤ VAI ≤ 1.03 rad is accepted as a level determinative for presence of TWA. VAI via Poincare mapping method (PM) is used for correlation analysis with T-wave alternans voltage (Vtwa) by way of the spectral method (SM). The cross-correlation coefficient between Vtwa and VAI is γ = 0.8601. The algorithm can identify the absence and presence of TWA accurately and provide idea for further study of TWA-PM.展开更多
Objective: To explore the application value of electrocardiograph (ECG) T-wave Alternans (TWA) anomaly in acute stage of intracerebral hemorrhage patients. Methods: We choose 1175 intracerebral hemorrhage patients who...Objective: To explore the application value of electrocardiograph (ECG) T-wave Alternans (TWA) anomaly in acute stage of intracerebral hemorrhage patients. Methods: We choose 1175 intracerebral hemorrhage patients whose conventional 12-lead ECG has TWA in our hospital from January 2011 to December 2015, 751 patients without TWA in the same period as the control group, compared the volume of intracerebral hemorrhage, bleeding site and mortality between the 2 groups. Results: In TWA group, 247 cases died, 361 cases with massive intracerebral hemorrhage, 298 cases with brain stem hemorrhage;in TWA negative group (control group), 41 cases died, 93 cases with massive brain hemorrhage, 64 cases with brain stem hemorrhage. There are statistical differences between two groups (P Conclusion: The occurrence of TWA is significantly related to the volume of bleeding, the bleeding site and mortality, and can be used as an important parameter in the prognosis of intracerebral hemorrhage.展开更多
文摘Objectives: There is a high rate of sudden death in epilepsy patients, part of which is sudden cardiac death. By investigating ECG T wave alternans and Q-T dispersion changes of epilepsy patients, we may predict the possibility of the occurrence of sudden death and provide basis for clinical prevention. Methods: Selecting 587 cases of epilepsy patients as the study group, 672 same period cases of healthy persons as the control group;Analyzing the effect of epilepsy on ECG T wave alternans and Q-T dispersion with the standard 12 lead ECG. Results: The study group had a significantly prolonged Q-T dispersion and an increased incidence of T wave alternans than that of the control group;Compared with other seizure types, tonic clonic seizure and absence seizure had a significantly prolonged Q-T dispersion and an increased occurrence rate of T wave alternans. Conclusions: Epilepsy patients ECG T wave alternans and Q-T dispersion has higher abnormal rate, and are prone to sudden cardiac death;Routine ECG(RECG) T wave alternans and Q-T dispersion changes can provide guidance for clinical prevention of sudden unexpected death in epilepsy (SUDEP).
文摘T-wave alternans (TWA), consisting in an alternation of the electrocardiographic (ECG) repolarization segment (T-wave), is a promising index of the risk of sudden cardiac death. By definition, it is characterized by a frequency component, termed fTWA, that matches half heart rate. The heart-rate adaptive match filter (AMF) based method is a technique for automatic TWA identification from the digital ECG. Aim of the present study was to provide a complete technical description of the filter able to explain its methodological principles. The AMF is usually realized as a 6th order Butterworth filter with a narrow (0.12 Hz) passing band centered in fTWA. It is applied in a bidirectional fashion, so that final filtering order is 12. While extracting the TWA component, the AMF simultaneously filters out every ECG component including noise and artefacts, and thus results are very robust. Goodness of the technique was tested using 8 synthetic ECG tracings corrupted by typical noisy factors, such as white random noise, baseline wanderings, heart-rate variability, and others. Six ECG tracings were affected by 100 μV TWA, whereas two were not. Results indicate that the AMF-based method is able to prevent false-positive and false-negative detections and, thus, represents a useful tool for a reliable TWA identification.
文摘Presently T-wave alternans (TWA) has become a clinical index of non-invasive diagnosis for heart sudden death prediction, and detecting T-wave alternate accurately is particularly important. This paper introduces an algorithm for detecting TWA using Poincare mapping method which is a technique for nonlinear dynamic systems to display periodic behavior. Sample series of beat to beat cycles were selected to prepare Poincare mapping method. Vector Angle Index (VAI), which is the mean of the difference between θi (the angle between the line connecting the i point to the origin and the X axis) and 45 degrees was used to present the presence or absence of TWA. The value of 0.9 rad ≤ VAI ≤ 1.03 rad is accepted as a level determinative for presence of TWA. VAI via Poincare mapping method (PM) is used for correlation analysis with T-wave alternans voltage (Vtwa) by way of the spectral method (SM). The cross-correlation coefficient between Vtwa and VAI is γ = 0.8601. The algorithm can identify the absence and presence of TWA accurately and provide idea for further study of TWA-PM.
文摘Objective: To explore the application value of electrocardiograph (ECG) T-wave Alternans (TWA) anomaly in acute stage of intracerebral hemorrhage patients. Methods: We choose 1175 intracerebral hemorrhage patients whose conventional 12-lead ECG has TWA in our hospital from January 2011 to December 2015, 751 patients without TWA in the same period as the control group, compared the volume of intracerebral hemorrhage, bleeding site and mortality between the 2 groups. Results: In TWA group, 247 cases died, 361 cases with massive intracerebral hemorrhage, 298 cases with brain stem hemorrhage;in TWA negative group (control group), 41 cases died, 93 cases with massive brain hemorrhage, 64 cases with brain stem hemorrhage. There are statistical differences between two groups (P Conclusion: The occurrence of TWA is significantly related to the volume of bleeding, the bleeding site and mortality, and can be used as an important parameter in the prognosis of intracerebral hemorrhage.