New Method of Measuring the Positive-sequence Capacitance of T-connection Transmission Lines
1
作者 Yuansen Zhang Demin Cui +6 位作者 Qingtao Cao Yongqiang Chai Peng Liu Xiaobo Li Zhijian Hu Chuanqi Li Chengxue Zhang 《Energy and Power Engineering》 2013年第4期941-944,共4页
A novel method of measuring the positive-sequence capacitance of T-connection transmission lines is proposed. The mathematical model of the new method is explained in detail. In order to obtain enough independent equa... A novel method of measuring the positive-sequence capacitance of T-connection transmission lines is proposed. The mathematical model of the new method is explained in detail. In order to obtain enough independent equations, three independent operation modes of T-connection transmission lines during the line measurement are introduced. The digital simulation results and field measurement results are shown. The simulation and measurement results have validated that the new method can meet the needs of measuring the positive-sequence capacitance of T-connection transmission lines. This method has been implemented in the newly developed measurement instrument. 展开更多
关键词 t-connection transmission lines line Parameter Positive-sequence CAPACITANCE Measurement
下载PDF
Study on Fault Location in the T-Connection Transmission Lines Based on Wavelet Transform
2
作者 Penggao Wen Hong Song +1 位作者 Zhiting Guo Quan Pan 《World Journal of Engineering and Technology》 2015年第3期106-115,共10页
The results of T-Line Traveling Wave Fault Location is easily influenced by the wave arrival time and traveling wave propagation velocity;it proposes that the traveling wave uses wavelet transform to extract the modul... The results of T-Line Traveling Wave Fault Location is easily influenced by the wave arrival time and traveling wave propagation velocity;it proposes that the traveling wave uses wavelet transform to extract the modulus maxima of breakdown voltage, to confirm the time of the traveling wave reaching the three-terminal line. The speed of the traveling wave reaching three terminals is confirmed by the structural parameters of the transmission line. We apply the arrival time and propagation velocity to the T-type traveling wave fault location algorithm. Different transmission line distance select the corresponding algorithm, excluding the impact of fault branches and in some cases ranging accuracy, the failure dead zone will not appear. After MATLAB simulation analysis, the algorithm analysis is clear;the range accuracy is high, so that it can meet the requirements of fault location. 展开更多
关键词 WAVELET Transform t-connection line TRAVELING WAVE FAULT TRAVELING WAVE FAULT Location
下载PDF
Digital Twin Modeling and Simulation Optimization of Transmission Front and Middle Case Assembly Line
3
作者 Xianfeng Cao Meihua Yao +2 位作者 Yahui Zhang Xiaofeng Hu Chuanxun Wu 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第6期3233-3253,共21页
As the take-off of China’s macro economy,as well as the rapid development of infrastructure construction,real estate industry,and highway logistics transportation industry,the demand for heavy vehicles is increasing ... As the take-off of China’s macro economy,as well as the rapid development of infrastructure construction,real estate industry,and highway logistics transportation industry,the demand for heavy vehicles is increasing rapidly,the competition is becoming increasingly fierce,and the digital transformation of the production line is imminent.As one of themost important components of heavy vehicles,the transmission front andmiddle case assembly lines have a high degree of automation,which can be used as a pilot for the digital transformation of production.To ensure the visualization of digital twins(DT),consistent control logic,and real-time data interaction,this paper proposes an experimental digital twin modeling method for the transmission front and middle case assembly line.Firstly,theDT-based systemarchitecture is designed,and theDT model is created by constructing the visualization model,logic model,and data model of the assembly line.Then,a simulation experiment is carried out in a virtual space to analyze the existing problems in the current assembly line.Eventually,some improvement strategies are proposed and the effectiveness is verified by a new simulation experiment. 展开更多
关键词 transmission front and middle case assembly line digital twin(DT) simulating optimization intelligent manufacturing
下载PDF
Research on Transmission Line Tower Tilting and Foundation State Monitoring Technology Based onMulti-Sensor Cooperative Detection and Correction
4
作者 Guangxin Zhang Minghui Liu +4 位作者 Shichao Cheng Minzhen Wang Changshun Zhao Hongdan Zhao Gaiming Zhong 《Energy Engineering》 EI 2024年第1期169-185,共17页
The transmission line tower will be affected by bad weather and artificial subsidence caused by the foundation and other factors in the power transmission.The tower’s tilt and severe deformation will cause the buildi... The transmission line tower will be affected by bad weather and artificial subsidence caused by the foundation and other factors in the power transmission.The tower’s tilt and severe deformation will cause the building to collapse.Many small changes caused the tower’s collapse,but the early staff often could not intuitively notice the changes in the tower’s state.In the current tower online monitoring system,terminal equipment often needs to replace batteries frequently due to premature exhaustion of power.According to the need for real-time measurement of power line tower,this research designed a real-time monitoring device monitoring the transmission tower attitude tilting and foundation state based on the inertial sensor,the acceleration of 3 axis inertial sensor and angular velocity raw data to pole average filtering pre-processing,and then through the complementary filtering algorithm for comprehensive calculation of tilt angle,the system meets the demand for inclined online monitoring of power line poles and towers regarding measurement accuracy,with low cost and power consumption.The optimization multi-sensor cooperative detection and correction measured tilt angle result relative accuracy can reach 1.03%,which has specific promotion and application value since the system has the advantages of unattended and efficient calculation. 展开更多
关键词 transmission line tower tilting MULTI-SENSOR foundation state monitoring collaborative detection
下载PDF
Minimization of Electric Power Losses on 132 kV and 220 kV Uganda Electricity Transmission Lines
5
作者 Ounyesiga Living Stephen Ndubuisi Nnamchi +2 位作者 Kelechi John Ukagwu Abubakar Abdulkarim Zaid Oluwadurotimi Jagun 《Energy and Power Engineering》 CAS 2023年第2期127-150,共24页
The classical minimization of power losses in transmission lines is dominated by artificial intelligence techniques, which do not guarantee global optimum amidst local minima. Revolutionary and evolutionary techniques... The classical minimization of power losses in transmission lines is dominated by artificial intelligence techniques, which do not guarantee global optimum amidst local minima. Revolutionary and evolutionary techniques are encumbered with sophisticated transformations, which weaken the techniques. Power loss minimization is crucial to the efficient design and operation of power transmission lines. Minimization of losses is one way to meet steady grid supply, especially at peak demand. Thus, this paper has presented a gradient technique to obtain optimal variables and values from the power loss model, which efficiently minimizes power losses by modifying the traditional power loss model that combines Ohm and Corona losses. Optimality tests showed that the unmodified model does not support the minimization of power losses on transmission lines as the Hessian matrix portrayed the maximization of power losses. However, the modified model is consistent with the gradient method of optimization, which yielded optimum variables and values from the power loss model developed in this study. The unmodified (modified) models for Bujagali-Kawanda 220 kV and Masaka West-Mbarara North 132 kV transmission lines in Uganda showed maximum power losses of 0.406 (0.391) and 0.452 (0.446) kW/km/phase respectively. These results indicate that the modified model is superior to the unmodified model in minimizing power losses in the transmission lines and should be implemented for the efficient design and operation of power transmission lines within and outside Uganda for the same transmission voltages. 展开更多
关键词 MINIMIZATION Power Losses transmission lines Corona and Ohms Losses transmission Model
下载PDF
Fault locating for traveling-wave accelerators based on transmission line theory
6
作者 Tong-Ning Hu Hai-Meng Wang +4 位作者 Yi-Feng Zeng Hong-Jie Xu Li Chen Guang-Yao Feng Yuan-Ji Pei 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第8期24-34,共11页
Radio-frequency(RF)breakdown analysis and location are critical for successful development of high-gradient traveling-wave(TW)accelerators,especially those expected to generate high-intensity,high-power beams.Compared... Radio-frequency(RF)breakdown analysis and location are critical for successful development of high-gradient traveling-wave(TW)accelerators,especially those expected to generate high-intensity,high-power beams.Compared with commonly used schemes involving dedicated devices or complicated techniques,a convenient approach for breakdown locating based on transmission line(TL)theory offers advantages in the typical constant-gradient TW-accelerating structure.To deliver such an approach,an equivalent TL model has been constructed to equate the TW-accelerating structure based on the fun-damental theory of the TL transient response in the time domain.An equivalence relationship between the TW-accelerating structure and the TL model has been established via analytical derivations associated with grid charts and verified by TL circuit simulations.Furthermore,to validate the proposed fault-locating method in practical applications,an elaborate analysis via such a method has been conducted for the recoverable RF-breakdown phenomena observed at an existing prototype of a TW-accelerating-structure-based beam injector constructed at the Huazhong University of Science and Technology.In addition,further considerations and discussion for extending the applications of the proposed method have been given.This breakdown-locating approach involving the transient response in the framework of TL theory can be a conceivable supple-ment to existing methods,facilitating solution to construction problems at an affordable cost. 展开更多
关键词 Traveling-wave structure RF breakdown Fault locating transmission line
下载PDF
Modeling and Simulation of a Transmission Line Response to a 400 kV/400V Capacitor Coupled Substation
7
作者 Sinqobile Wiseman Nene Bolanle Tolulope Abe Agha Francis Nnachi 《Journal of Power and Energy Engineering》 2023年第12期1-14,共14页
The access to electricity in rural areas is extremely limited, but it is crucial for all citizens. The population in rural areas of sub-Saharan African (SSA) countries is generally low, making it economically unfeasib... The access to electricity in rural areas is extremely limited, but it is crucial for all citizens. The population in rural areas of sub-Saharan African (SSA) countries is generally low, making it economically unfeasible to implement traditional rural electrification (CRE) projects due to the high cost of establishing the necessary distribution infrastructure. To address this cost issue, one alternative technology for rural electrification (URE) that can be explored is the Capacitor Coupled Substation (CCS) technology. CCS is a cost-effective solution for supplying electricity to rural areas. The research is necessitated by the need to offer a cost-effective technology for supplying electricity to sparsely populated communities. This paper examines the impact on the transmission network when a 400 kV/400V CCS is connected to it. The system response when a CCS is connected to the network was modeled using MATLAB/Si-mulink. The results, based on the fixed load of 80 kW, showed negligible interference on the transmission line voltage. However, there was minor impact on the parameters downstream of the tapping point. These findings were further supported by introducing a fault condition to the CCS, which showed that interferences with the CCS could affect the overall stability of the transmission network downstream of the tapping node, similar to the behavior of an unstable load. 展开更多
关键词 Capacitor Coupled Substation Conventional Rural Electrification Unconventional Rural Electrification transmission line Behavior Power System Simulation
下载PDF
Transmission Line Modelling of Geomagnetic Induction in the Ocean/Earth Conductivity Structure
8
作者 David H. Boteler Shibaji Chakraborty +2 位作者 Xueling Shi Michael D. Hartinger Xuan Wang 《International Journal of Geosciences》 2023年第8期767-791,共25页
During geomagnetic disturbances, electric fields induced in the Earth and in power systems, pipelines and submarine cables can interfere with the operation of these systems. Calculations for submarine cables are compl... During geomagnetic disturbances, electric fields induced in the Earth and in power systems, pipelines and submarine cables can interfere with the operation of these systems. Calculations for submarine cables are complicated by the need to consider not just the induction directly into the cable but also the earth potentials produced at the coast at each end of the cable. To determine the coast potentials, we present a new model of the ocean and earth conductivity structure that spans the whole length of a cable from one coast to another. Calculations are based on the generalised thin sheet approach introduced by Ranganayaki and Madden but converted to a transmission line model that can be solved using standard circuit theory techniques. It is shown how the transmission line model can be used to calculate the earth potential profile from one side of an ocean or sea to the other. Example calculations are presented for a shallow sea, a shallow ocean, and a deep ocean that are simplified approximations to the North Sea, Tasman Sea and Pacific Ocean and show that the peak potentials occur at the coast. An examination is also made of how the width of a shallow sea and the width of the continental shelf affect these coast potentials. The modelling technique and example results provide a guide for more detailed modelling of geomagnetic induction along the routes of specific submarine cables. 展开更多
关键词 Geomagnetic Induction Generalised Thin Sheet transmission line Modelling Coast Potentials Submarine Cables
下载PDF
OPTIMIZATION OF TRANSIENT FEEDING TO PARALLEL-PLATE TRANSMISSION LINES FROM COAXIAL LINE 被引量:4
9
作者 Tian Chunming Wang Jianguo Meng Fenxia Zhang Maoyu Ge Debiao(Department of Physics, Xidian University, Xi’an 710071) (Northwest Institute of Nuclear Technology, P. O. Box 69-15, Xi’an 710024) 《Journal of Electronics(China)》 2001年第3期281-284,共4页
The transient feeding to parallel-plate transmission lines from coaxial line is optimized by using the Finite-Difference Time-Domain (FDTD) method and a simple FDTD feed model. Observing the reflected voltages, this l... The transient feeding to parallel-plate transmission lines from coaxial line is optimized by using the Finite-Difference Time-Domain (FDTD) method and a simple FDTD feed model. Observing the reflected voltages, this letter presents the optimal feeding position and ratio of width to height for a given input impedance of the coaxial line. 展开更多
关键词 FDTD method Parallel-plate transmission lines
下载PDF
Reduction of electric field strength by two species of trees under power transmission lines 被引量:2
10
作者 Hongwei Zhou Liping Sun +4 位作者 Yang Yang Che Liu Tianshi Liu Penghao Xie Ling Ma 《Journal of Forestry Research》 SCIE CAS CSCD 2018年第5期1415-1422,共8页
Electrical pollution is a worldwide concern,because it is potentially harmful to human health.Trees not only play a significant role in moderating the climate,but also can be used as shields against electrical polluti... Electrical pollution is a worldwide concern,because it is potentially harmful to human health.Trees not only play a significant role in moderating the climate,but also can be used as shields against electrical pollution.Shielding effects on the electric field strength under transmission lines by two tree species,Populus alba and Larix gmelinii,were examined in this study.The electrical resistivity at different heights of trees was measured using a PiCUS sonic tomograph,which can image the electrical impedance for trees.The electric field strength around the trees was measured with an elf field strength measurement system,HI-3604,and combined with tree resistivity to develop a model for calculating the electric field intensity around trees using the finite element method.In addition,the feasibility of the finite element method was confirmed by comparing the calculated results and experimental data.The results showed that the trees did reduce the electric field strength.The electric field intensity was reduced by 95.6%,and P.alba was better than L.gmelinii at shielding. 展开更多
关键词 Trees Power transmission lines Electric environment Tree electrical resistivity SHIELDING Finite element method
下载PDF
Analysis of field coupling to transmission lines with random rotation over the ground 被引量:1
11
作者 谢海燕 李勇 +1 位作者 乔海亮 王建国 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第6期171-176,共6页
In this paper we analyze plane wave coupling to transmission lines rotating randomly over an infinite and perfectly conducting ground and present an efficient method to calculate average voltage. Under the assumption ... In this paper we analyze plane wave coupling to transmission lines rotating randomly over an infinite and perfectly conducting ground and present an efficient method to calculate average voltage. Under the assumption of small rotation quantity, the factors affecting the induced voltage and their effects are analyzed and then an efficient method to calculate the average voltage is presented when the distribution of the random rotation angles is uniform in [-π, π]. The results show that voltage variation is mainly due to the change of the source term. The effects of the source term increase linearly with the magnitude of the incident wave, change periodically with the rotation angle, and are larger in the high frequency range than in the low frequency range. The results show that the average voltages obtained by the proposed method agree well with those via the Monte Carlo method and the proposed method is much more efficient. The results also imply that the effect of random rotation is more important than that of random translation. 展开更多
关键词 electromagnetic interference induced voltage RANDOMNESS statistical analysis transmission line
下载PDF
Steady-state voltage-control method considering large-scale wind-power transmission using half-wavelength transmission lines 被引量:3
12
作者 Hao Tian Hongzheng Liu +3 位作者 Huan Ma Pengfei Zhang Xiaohui Qin Changhui Ma 《Global Energy Interconnection》 EI CAS CSCD 2021年第3期239-250,共12页
Half-wavelength transmission can transmit large-scale renewable energy over very long distances.This paper proposes an improved steady-state voltage-control method for half-wavelength transmission systems considering ... Half-wavelength transmission can transmit large-scale renewable energy over very long distances.This paper proposes an improved steady-state voltage-control method for half-wavelength transmission systems considering largescale wind-power transmission.First,the unique voltage characteristics of half-wavelength lines are deduced based on the distributed parameter model.In the secondary voltage-control level,reactive power-transmission limits of half-wavelength lines are introduced as another control objective except for tracing the pilot bus voltage reference.Considering the uncertainty and fluctuation of wind power,the overvoltage risk-assessment method of half-wavelength lines is presented to determine specific voltage-control strategies.Simulation results demonstrate that the proposed voltage-control method delivers superior tracking performance according to a voltage reference value and prevents the overvoltage risk of halfwavelength lines effectively in different wind-power penetrations. 展开更多
关键词 Half-wavelength lines Secondary voltage control Wind-power transmission Reactive power regulation
下载PDF
Tracking Galloping Profile of Transmission Lines Using Wireless Inertial Measurement Units 被引量:2
13
作者 Kai Xie Chao Zhang +2 位作者 Qing Li Wang-Lin Wu Yi-Qing Ni 《Journal of Computer and Communications》 2015年第5期220-228,共9页
Galloping of power transmission lines might bring about huge damage such as massive power outage and collapse of the transmission towers. To realize forecast of the galloping and provide data for study on the gallopin... Galloping of power transmission lines might bring about huge damage such as massive power outage and collapse of the transmission towers. To realize forecast of the galloping and provide data for study on the galloping mechanism, this paper proposes an online monitoring system for tracking galloping profile of power transmission lines based on wireless inertial measurement units (WIMUs). The system is composed of three modules: wireless inertial measurement nodes, monitoring base station, and remote monitoring station. After detailing the hardware system, the corresponding software which positions and displays galloping profile of the transmission line in real-time is outlined. The feasibility of the proposed on-line monitoring system is demonstrated through a series of experiments at the State Grid Key Laboratory of Power Overhead Transmission Line Galloping (Zhengzhou, China) by taking into account different vibration patterns. 展开更多
关键词 Power transmission lines GALLOPING Vibration ON-line Monitoring WIRELESS INERTIAL Measurement Units
下载PDF
Critical Length Criterion and the Arc Chain Model for Calculating the Arcing Time of the Secondary Arc Related to AC Transmission Lines 被引量:1
14
作者 丛浩熹 李庆民 +2 位作者 行晋源 李劲松 陈强 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第6期475-480,共6页
The prompt extinction of the secondary arc is critical to the single-phase reclosing of AC transmission lines, including half-wavelength power transmission lines. In this paper, a low- voltage physical experimental pl... The prompt extinction of the secondary arc is critical to the single-phase reclosing of AC transmission lines, including half-wavelength power transmission lines. In this paper, a low- voltage physical experimental platform was established and the motion process of the secondary arc was recorded by a high-speed camera. It was found that the arcing time of the secondary arc rendered a close relationship with its arc length. Through the input and output power energy analysis of the secondary arc, a new critical length criterion for the arcing time was proposed. The arc chain model was then adopted to calculate the arcing time with both the traditional and the proposed critical length criteria, and the simulation results were compared with the experimental data. The study showed that the arcing time calculated from the new critical length criterion gave more accurate results, which can provide a reliable criterion in term of arcing time for modeling and simulation of the secondary arc related with power transmission lines. 展开更多
关键词 AC transmission lines secondary arc arcing time dynamic modeling criticallength criterion
下载PDF
Fiber Bragg grating monitors for thermal and stress of the composite insulators in transmission lines 被引量:6
15
作者 Heming Deng Wei Cai +3 位作者 You Song Jinsong Liu Christopher Redman Qiandong Zhuang 《Global Energy Interconnection》 2018年第3期382-390,共9页
Running composite insulators are prone to failure due to their harsh surrounding work environment, which directly affects the safe operation of transmission lines. This paper puts forward the method of using fiber Bra... Running composite insulators are prone to failure due to their harsh surrounding work environment, which directly affects the safe operation of transmission lines. This paper puts forward the method of using fiber Bragg grating(FBG) as the monitors to parameters correlated with thermal and stress of the composite insulators in transmission lines at working status. Firstly, monitoring points are found out by the mechanical test on composite insulator samples. Secondly, based on the monitoring theory, this paper introduces the feasibility design frame of the composite insulator with FBG implanted in the rod and the online monitor system. At last, it describes applications of this monitor system in the field of transmission lines. 展开更多
关键词 Thermal monitoring Stress monitoring Composite insulators transmission lines Fiber Bragg grating monitors
下载PDF
CONFORMAL TRANSFORMATION SOLUTION FOR THE ATTENUATION CONSTANT OF TEM TRANSMISSION LINES 被引量:1
16
作者 梁昌洪 崔铁军 范小平 《Journal of Electronics(China)》 1992年第1期45-53,共9页
The conformal transformation solution is presented for the attenuation constant ofTEM transmission lines which can be mapped into the coaxial or the parallel plate lines by certainconformal transformations including t... The conformal transformation solution is presented for the attenuation constant ofTEM transmission lines which can be mapped into the coaxial or the parallel plate lines by certainconformal transformations including the numerical ones.The analytic and numerical results ofsome examples are also given. 展开更多
关键词 transmission line CONFORMAL TRANSFORMATION ATTENUATION CONSTANT TEM mode MAPPING
下载PDF
FDTD Analysis of Nonuniform Lossy Cascade Multiconductor Transmission Lines 被引量:1
17
作者 付继伟 侯朝桢 窦丽华 《Journal of Beijing Institute of Technology》 EI CAS 2004年第4期373-377,共5页
A hybrid algorithm is presented for nonuniform lossy multiconductor transmission lines (MTL) connected by arbitrary linear load networks. The networks are characterized by a state-variable equation which allows a gene... A hybrid algorithm is presented for nonuniform lossy multiconductor transmission lines (MTL) connected by arbitrary linear load networks. The networks are characterized by a state-variable equation which allows a general characterization of dynamic elements in the cascade networks. The method is achieved by the finite difference-time domain (FDTD) algorithm for the MTL, and the skin effect is taken into account, the more accurate method is used to compute the skin effect. And this method is combined with the computation of the nonuniform transmission lines. Finally, several numerical examples are given, these results indicate that: the current of the lossy MTL is smaller than the lossless of the MTL; and when the load networks contain the dynamic element, the transition time of the current is longer than the MTL connected by resistance only. 展开更多
关键词 NONUNIFORM cascade networks lossy multiconductor transmission lines(MTL) finite difference-time domain (FDTD)
下载PDF
The Ultraviolet Detection of Corona Discharge in Power Transmission Lines 被引量:1
18
作者 Lan Chen Lin Lin +3 位作者 Mimi Tian Xingming Bian Liming Wang Zhicheng Guan 《Energy and Power Engineering》 2013年第4期1298-1302,共5页
Corona discharge is a common phenomenon in power transmission lines external insulation, and it may cause serious defect if without effective detection. The ultraviolet (UV) imagery technology has been widely used to ... Corona discharge is a common phenomenon in power transmission lines external insulation, and it may cause serious defect if without effective detection. The ultraviolet (UV) imagery technology has been widely used to detect the corona discharge in industry in recent years, but some influence factors’ functions are not definite. In this paper, the fracture aluminum strands which is common in power transmission lines were used as the electrode model while a SuperB ultraviolet imager were utilized to detect, the photon count rate was detected with different detect distance, electric field, aluminum strands length and UV gain were applied. Then the multivariate regression analysis (MRA) was taken to calculate the function between the photon count and the factors. 展开更多
关键词 CORONA DISCHARGE transmission lines DEFECT Detection UV IMAGER MULTIVARIATE Regression Analysis
下载PDF
General Analytic Solution of the Telegrapher’s Equations and the Resulting Consequences for Electrically Short Transmission Lines 被引量:1
19
作者 Steffen Kü hn 《Journal of Electromagnetic Analysis and Applications》 2020年第6期71-87,共17页
Based on classical circuit theory, this article develops a general analytic solution of the telegrapher’s equations, in which the length of the cable is explicitly contained as a freely adjustable parameter. For this... Based on classical circuit theory, this article develops a general analytic solution of the telegrapher’s equations, in which the length of the cable is explicitly contained as a freely adjustable parameter. For this reason, the solution is also applicable to electrically short cables. Such a model has become indispensable because a few months ago, it was experimentally shown that voltage fluctuations in ordinary but electrically short copper lines move at signal velocities that are significantly higher than the speed of light in a vacuum. This finding contradicts the statements of the special theory of relativity but not, as is shown here, the fundamental principles of electrical engineering. Based on the general transfer function of a transmission line, the article shows mathematically that an unterminated, electrically short cable has the characteristics of an ideal delay element, meaning that an input signal appears at the output with a slight delay but remains otherwise unchanged. Even for conventional cables, the time constants can be so small that the corresponding signal velocities can significantly exceed the speed of light in a vacuum. The article also analyses the technical means with which this effect can be conveyed to very long cables. 展开更多
关键词 Telegrapher’s Equations transmission line Theory Special Theory of Relativity Electrically Short transmission lines FTL Communication
下载PDF
Coupling analysis of transmission lines excited by space electromagnetic fields based on time domain hybrid method using parallel technique 被引量:1
20
作者 叶志红 吴小林 李尧尧 《Chinese Physics B》 SCIE EI CAS CSCD 2020年第9期249-254,共6页
We present a time domain hybrid method to realize the fast coupling analysis of transmission lines excited by space electromagnetic fields, in which parallel finite-difference time-domain (FDTD) method, interpolation ... We present a time domain hybrid method to realize the fast coupling analysis of transmission lines excited by space electromagnetic fields, in which parallel finite-difference time-domain (FDTD) method, interpolation scheme, and Agrawal model-based transmission line (TL) equations are organically integrated together. Specifically, the Agrawal model is employed to establish the TL equations to describe the coupling effects of space electromagnetic fields on transmission lines. Then, the excitation fields functioning as distribution sources in TL equations are calculated by the parallel FDTD method through using the message passing interface (MPI) library scheme and interpolation scheme. Finally, the TL equations are discretized by the central difference scheme of FDTD and assigned to multiple processors to obtain the transient responses on the terminal loads of these lines. The significant feature of the presented method is embodied in its parallel and synchronous calculations of the space electromagnetic fields and transient responses on the lines. Numerical simulations of ambient wave acting on multi-conductor transmission lines (MTLs), which are located on the PEC ground and in the shielded cavity respectively, are implemented to verify the accuracy and efficiency of the presented method. 展开更多
关键词 Agrawal model transmission line equations parallel FDTD method message passing interface(MPI)library
下载PDF