Complex tibial plateau fractures can seriously affect quality of life and physical and mental health of patients.The anatomical relationship between the proximal tibial bone and soft tissue is complex,resulting in dif...Complex tibial plateau fractures can seriously affect quality of life and physical and mental health of patients.The anatomical relationship between the proximal tibial bone and soft tissue is complex,resulting in different types of tibial plateau fractures.Violent trauma can lead to displaced fracture,serious soft tissue injury,and potentially,dislocation of the knee joint.Therefore,tibial plateau fractures are extremely unstable.AIM To assess the use of locking compression plate(LCP)+T-type steel plate for postoperative weight bearing and functional recovery of complex tibial plateau fractures.METHODS Ninety-seven patients with complex tibial plateau fractures who underwent surgery at our hospital were selected for retrospective study.Forty-nine patients had been treated with LCP+T-type steel plate limited internal fixation(study group),and 48 patients with bilateral ordinary steel plate support(control group).The operation process index,postoperative rehabilitation related index,Rasmussen score of the knee joint,tibial plateau varus angle(TPA),tibial plateau retroversion angle(PA),and surgical complications of the two groups were compared.RESULTS The operation time and intraoperative bone graft volume in the study group were lower than those in the control group(P<0.05).There were no significant differences in surgical bleeding,anterior external incision length,postoperative drainage,hospital stay duration,and fracture healing time between the groups(P>0.05).There was no significant difference in the TPA and PA angle between the groups immediately and 18 mo after surgery(P>0.05).At 12 mo after surgery,the Rasmussen scale score was higher in the study group than in the control group(P<0.05).There was no significant difference in the Rasmussen scale score at 18 mo after surgery,and the radiology score at 12 and 18 mo after surgery,between the two groups(P>0.05).The postoperative complication rate in the study group(3.77%)was lower than that in the control group(15.09%;P<0.05).CONCLUSION LCP+T-type steel plate internal fixation has advantages in terms of minimizing trauma and enabling early postoperative functional exercise,promoting functional recovery and lower limb weight-bearing,and reducing postoperative complications.展开更多
近年来,中央银行数字货币(CBDC)受到全球多个国家和地区的高度关注.双离线交易作为CBDC的可选属性,在无网络连接的情况下进行支付,被认为具有较大的实用价值.面向CBDC的双离线匿名支付场景,基于可信执行环境(TEE)和安全单元(SE)技术,提...近年来,中央银行数字货币(CBDC)受到全球多个国家和地区的高度关注.双离线交易作为CBDC的可选属性,在无网络连接的情况下进行支付,被认为具有较大的实用价值.面向CBDC的双离线匿名支付场景,基于可信执行环境(TEE)和安全单元(SE)技术,提出了一种专为移动平台设计的高效双离线匿名支付方案(dual offline anonymous E-payment for mobile devices,OAPM).OAPM适用于资源受限的移动设备,允许移动付款者在不联网状态下安全地向收款者支付数字货币,且不向收款者及商业银行泄露个人隐私信息,付款者的支付行为也不会被链接,同时允许收款者设备处于离线状态,监管机构(如中央银行)在必要情况下能够识别匿名付款者的真实身份.该方案满足数字货币交易的多项重要属性,包括正确性、不可链接性、可追踪性、不可陷害性、机密性、真实性、防双花性以及可控匿名性等.实现了原型系统,并对可能的参数进行了评估.安全性分析和实验结果表明,该方案从安全性和效率两方面均能满足移动用户CBDC双离线交易的实际需求.展开更多
The impedance characteristics of distributed amplifiers are analyzed based on T-type matching networks, and a distributed power amplifier consisting of three gain cells is proposed. Non-uniform T-type matching network...The impedance characteristics of distributed amplifiers are analyzed based on T-type matching networks, and a distributed power amplifier consisting of three gain cells is proposed. Non-uniform T-type matching networks are adopted to make the impedance of artificial transmission lines connected to the gate and drain change stage by stage gradually, which provides good impedance matching and improves the output power and efficiency. The measurement results show that the amplifier gives an average forward gain of 6 dB from 3 to 16. 5 GHz. In the desired band, the input return loss is typically less than - 9. 5 dB, and the output return loss is better than -8.5 dB. The output power at 1-dB gain compression point is from 3.6 to 10. 6 dBm in the band of 2 to 16 GHz while the power added efficiency (PAE) is from 2% to 12. 5% . The power consumption of the amplifier is 81 mW with a supply of 1.8 V, and the chip area is 0.91 mm × 0.45 mm.展开更多
文摘Complex tibial plateau fractures can seriously affect quality of life and physical and mental health of patients.The anatomical relationship between the proximal tibial bone and soft tissue is complex,resulting in different types of tibial plateau fractures.Violent trauma can lead to displaced fracture,serious soft tissue injury,and potentially,dislocation of the knee joint.Therefore,tibial plateau fractures are extremely unstable.AIM To assess the use of locking compression plate(LCP)+T-type steel plate for postoperative weight bearing and functional recovery of complex tibial plateau fractures.METHODS Ninety-seven patients with complex tibial plateau fractures who underwent surgery at our hospital were selected for retrospective study.Forty-nine patients had been treated with LCP+T-type steel plate limited internal fixation(study group),and 48 patients with bilateral ordinary steel plate support(control group).The operation process index,postoperative rehabilitation related index,Rasmussen score of the knee joint,tibial plateau varus angle(TPA),tibial plateau retroversion angle(PA),and surgical complications of the two groups were compared.RESULTS The operation time and intraoperative bone graft volume in the study group were lower than those in the control group(P<0.05).There were no significant differences in surgical bleeding,anterior external incision length,postoperative drainage,hospital stay duration,and fracture healing time between the groups(P>0.05).There was no significant difference in the TPA and PA angle between the groups immediately and 18 mo after surgery(P>0.05).At 12 mo after surgery,the Rasmussen scale score was higher in the study group than in the control group(P<0.05).There was no significant difference in the Rasmussen scale score at 18 mo after surgery,and the radiology score at 12 and 18 mo after surgery,between the two groups(P>0.05).The postoperative complication rate in the study group(3.77%)was lower than that in the control group(15.09%;P<0.05).CONCLUSION LCP+T-type steel plate internal fixation has advantages in terms of minimizing trauma and enabling early postoperative functional exercise,promoting functional recovery and lower limb weight-bearing,and reducing postoperative complications.
文摘近年来,中央银行数字货币(CBDC)受到全球多个国家和地区的高度关注.双离线交易作为CBDC的可选属性,在无网络连接的情况下进行支付,被认为具有较大的实用价值.面向CBDC的双离线匿名支付场景,基于可信执行环境(TEE)和安全单元(SE)技术,提出了一种专为移动平台设计的高效双离线匿名支付方案(dual offline anonymous E-payment for mobile devices,OAPM).OAPM适用于资源受限的移动设备,允许移动付款者在不联网状态下安全地向收款者支付数字货币,且不向收款者及商业银行泄露个人隐私信息,付款者的支付行为也不会被链接,同时允许收款者设备处于离线状态,监管机构(如中央银行)在必要情况下能够识别匿名付款者的真实身份.该方案满足数字货币交易的多项重要属性,包括正确性、不可链接性、可追踪性、不可陷害性、机密性、真实性、防双花性以及可控匿名性等.实现了原型系统,并对可能的参数进行了评估.安全性分析和实验结果表明,该方案从安全性和效率两方面均能满足移动用户CBDC双离线交易的实际需求.
基金The National Natural Science Foundation of China(No.61106021)the Postdoctoral Science Foundation of China(No.2015M582541)+1 种基金the Natural Science Foundation of Higher Education Institutions of Jiangsu Province(No.15KJB510020)the Research Fund of Nanjing University of Posts and Telecommunications(No.NY215140,No.NY215167)
文摘The impedance characteristics of distributed amplifiers are analyzed based on T-type matching networks, and a distributed power amplifier consisting of three gain cells is proposed. Non-uniform T-type matching networks are adopted to make the impedance of artificial transmission lines connected to the gate and drain change stage by stage gradually, which provides good impedance matching and improves the output power and efficiency. The measurement results show that the amplifier gives an average forward gain of 6 dB from 3 to 16. 5 GHz. In the desired band, the input return loss is typically less than - 9. 5 dB, and the output return loss is better than -8.5 dB. The output power at 1-dB gain compression point is from 3.6 to 10. 6 dBm in the band of 2 to 16 GHz while the power added efficiency (PAE) is from 2% to 12. 5% . The power consumption of the amplifier is 81 mW with a supply of 1.8 V, and the chip area is 0.91 mm × 0.45 mm.