The application of the Euclidean division theorem for the positive integers allowed us to establish a set which contains all the prime numbers and this set we called it set of supposedly prime numbers and we noted it ...The application of the Euclidean division theorem for the positive integers allowed us to establish a set which contains all the prime numbers and this set we called it set of supposedly prime numbers and we noted it E<sub>sp</sub>. We subsequently established from the previous set the set of non-prime numbers (the set of numbers belonging to this set and which are not prime) denoted E<sub>np</sub>. We then extracted from the set of supposedly prime numbers the numbers which are not prime and the set of remaining number constitutes the set of prime numbers denoted E<sub>p</sub>. We have deduced from the previous set, the set of prime numbers between two natural numbers. We have explained during our demonstrations the origin of the twin prime numbers and the structure of the chain of prime numbers.展开更多
Classical Mechanics using Einstein’s theories of relativity places a limit on speed as the speed of light. Quantum Mechanics has no such limitation. To understand space accelerating faster than the speed of light and...Classical Mechanics using Einstein’s theories of relativity places a limit on speed as the speed of light. Quantum Mechanics has no such limitation. To understand space accelerating faster than the speed of light and information being exchanged instantaneously between two entangled electrons separated by huge distances, one uses Planck’s length, Planck’s time, and Planck’s mass to indicate that space and time are discrete and therefore along with masses smaller than Planck’s mass are Quantum Mechanical in nature. Faster than the speed of light c = 3 × 10<sup>8</sup> m/s is a classical effect only in dimensions of space lower than our 3-D Universe, but it is a Quantum effect in all dimensions of space. Because space can oscillate sending out ripples from the source, it is the medium used for transporting light waves and gravity waves.展开更多
AIM:To compare the imaging results with histology and to evaluate the diagnostic sensitivity of imaging modalities for hepatocellular carcinoma(HCC)smaller than 2 cm.METHODS:Nodules smaller than 2 cm(n=34)revealed by ...AIM:To compare the imaging results with histology and to evaluate the diagnostic sensitivity of imaging modalities for hepatocellular carcinoma(HCC)smaller than 2 cm.METHODS:Nodules smaller than 2 cm(n=34)revealed by ultrasonography(US)in 29 patients with liver cirrhosis were analyzed.Histological diagnosis of HCC was performed by ultrasonographic guidance:moderately-differentiated HCC(n=24);well-differentiated HCC(n=10).The patterns disclosed by the four imaging modalities defined the conclusive diagnosis of HCC:(1)contrast-enhanced computed tomography(CECT),hypervascularity in the arterial phase and washout in the equilibrium phase;(2)Sonazoid contrast-enhanced US(CEUS),hypervascularity in the early vascular phase and defect in the Kupffer phase;(3)gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid(Gd-EOBDTPA)-enhanced magnetic resonance imaging(MRI),hypervascularity in the arterial phase and/or defect in the hepatobiliary phase;and(4)CT arterioportal angiography:hypervascularity by CT during arteriography and/ or perfusion defect by CT during arterial portography.RESULTS:Overall,the sensitivity of diagnosing HCC smaller than 2 cm was 52.9%(18/34)(95%CI:35.170.2)by CECT;67.6%(23/34)(95%CI:49.5-82.6)by Sonazoid CEUS;76.5%(26/34)(95%CI:58.8-89.3) by Gd-EOB-DTPA MRI;and 88.2%(30/34)(95%CI: 72.5-96.7)by CT arterioportal angiography.The diagnostic sensitivity of detecting moderately-differentiated HCC by CECT,Sonazoid CEUS,Gd-EOB-DTPA MRI and CT arterioportal angiography was 62.5%(15/24)(95%CI: 40.6-81.2),79.2%(19/24)(95%CI:57.8-92.9),75.0% (18/24)(95%CI:53.3-90.2)and 95.8%(23/24)(95% CI:78.9-99.9),respectively.A significant difference(P< 0.05)was observed between CECT and CT arterioportal angiography in all nodules.There was no difference between Sonazoid CEUS,Gd-EOB-DTPA MRI,and CT arterioportal angiography.The combined sensitivity of Sonazoid CEUS and Gd-EOB-DTPA MRI was 94.1%(32/34).CONCLUSION:Changing the main diagnostic modality for HCC smaller than 2 cm from CT arterioportal angiography to Sonazoid CEUS and Gd-EOB-DTPA MRI is recommended.展开更多
This article uses insights from the principles of textuality, through comparison and contrast of three translation versions on the same classical Chinese literature, intents to explain the functional dimension and pra...This article uses insights from the principles of textuality, through comparison and contrast of three translation versions on the same classical Chinese literature, intents to explain the functional dimension and pragmatic value achieved in the target text. It argues that informativity, intentionality, situationality and acceptability are crucial premeters for information transfer of the original text.展开更多
Since the early work of O.M.Bilanuik and B.C.Sudarshan in 1962 and G.Feinberg in 1967, the research work on the faster-than-light (superluminal) has been performed in the world, such as in USA, Europe and China. In th...Since the early work of O.M.Bilanuik and B.C.Sudarshan in 1962 and G.Feinberg in 1967, the research work on the faster-than-light (superluminal) has been performed in the world, such as in USA, Europe and China. In this paper, the development stages of the study are presented, which include beginning stage, transitional stage and experimental stage. Based on the Einstein’s paper in 1905, the velocities greater than that of light had no possibility of existence. However, in the Einstein’s papers of 1907 it was founded that the superluminal signal speed could not be refuted absolutely. In this paper, the studies on velocities are classified. The definition of General Information Speed is suggested, which will ease the discussion. After reviewing the researches of 1962-2004, it can be concluded that the faster-than-light is a realizable scientific statement.展开更多
As a leading global trade fair,ISPO MUNICH is on the most important industry and network platforms in the sports business:More than 2,700 exhibitors present trends and new products for the upcoming season each year i...As a leading global trade fair,ISPO MUNICH is on the most important industry and network platforms in the sports business:More than 2,700 exhibitors present trends and new products for the upcoming season each year in 16 halls.ISPO MUNICH 2018 will focus on major topics like digitalization,cross-industry,women in sports and sustainability.展开更多
文摘The application of the Euclidean division theorem for the positive integers allowed us to establish a set which contains all the prime numbers and this set we called it set of supposedly prime numbers and we noted it E<sub>sp</sub>. We subsequently established from the previous set the set of non-prime numbers (the set of numbers belonging to this set and which are not prime) denoted E<sub>np</sub>. We then extracted from the set of supposedly prime numbers the numbers which are not prime and the set of remaining number constitutes the set of prime numbers denoted E<sub>p</sub>. We have deduced from the previous set, the set of prime numbers between two natural numbers. We have explained during our demonstrations the origin of the twin prime numbers and the structure of the chain of prime numbers.
文摘Classical Mechanics using Einstein’s theories of relativity places a limit on speed as the speed of light. Quantum Mechanics has no such limitation. To understand space accelerating faster than the speed of light and information being exchanged instantaneously between two entangled electrons separated by huge distances, one uses Planck’s length, Planck’s time, and Planck’s mass to indicate that space and time are discrete and therefore along with masses smaller than Planck’s mass are Quantum Mechanical in nature. Faster than the speed of light c = 3 × 10<sup>8</sup> m/s is a classical effect only in dimensions of space lower than our 3-D Universe, but it is a Quantum effect in all dimensions of space. Because space can oscillate sending out ripples from the source, it is the medium used for transporting light waves and gravity waves.
文摘AIM:To compare the imaging results with histology and to evaluate the diagnostic sensitivity of imaging modalities for hepatocellular carcinoma(HCC)smaller than 2 cm.METHODS:Nodules smaller than 2 cm(n=34)revealed by ultrasonography(US)in 29 patients with liver cirrhosis were analyzed.Histological diagnosis of HCC was performed by ultrasonographic guidance:moderately-differentiated HCC(n=24);well-differentiated HCC(n=10).The patterns disclosed by the four imaging modalities defined the conclusive diagnosis of HCC:(1)contrast-enhanced computed tomography(CECT),hypervascularity in the arterial phase and washout in the equilibrium phase;(2)Sonazoid contrast-enhanced US(CEUS),hypervascularity in the early vascular phase and defect in the Kupffer phase;(3)gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid(Gd-EOBDTPA)-enhanced magnetic resonance imaging(MRI),hypervascularity in the arterial phase and/or defect in the hepatobiliary phase;and(4)CT arterioportal angiography:hypervascularity by CT during arteriography and/ or perfusion defect by CT during arterial portography.RESULTS:Overall,the sensitivity of diagnosing HCC smaller than 2 cm was 52.9%(18/34)(95%CI:35.170.2)by CECT;67.6%(23/34)(95%CI:49.5-82.6)by Sonazoid CEUS;76.5%(26/34)(95%CI:58.8-89.3) by Gd-EOB-DTPA MRI;and 88.2%(30/34)(95%CI: 72.5-96.7)by CT arterioportal angiography.The diagnostic sensitivity of detecting moderately-differentiated HCC by CECT,Sonazoid CEUS,Gd-EOB-DTPA MRI and CT arterioportal angiography was 62.5%(15/24)(95%CI: 40.6-81.2),79.2%(19/24)(95%CI:57.8-92.9),75.0% (18/24)(95%CI:53.3-90.2)and 95.8%(23/24)(95% CI:78.9-99.9),respectively.A significant difference(P< 0.05)was observed between CECT and CT arterioportal angiography in all nodules.There was no difference between Sonazoid CEUS,Gd-EOB-DTPA MRI,and CT arterioportal angiography.The combined sensitivity of Sonazoid CEUS and Gd-EOB-DTPA MRI was 94.1%(32/34).CONCLUSION:Changing the main diagnostic modality for HCC smaller than 2 cm from CT arterioportal angiography to Sonazoid CEUS and Gd-EOB-DTPA MRI is recommended.
文摘This article uses insights from the principles of textuality, through comparison and contrast of three translation versions on the same classical Chinese literature, intents to explain the functional dimension and pragmatic value achieved in the target text. It argues that informativity, intentionality, situationality and acceptability are crucial premeters for information transfer of the original text.
文摘Since the early work of O.M.Bilanuik and B.C.Sudarshan in 1962 and G.Feinberg in 1967, the research work on the faster-than-light (superluminal) has been performed in the world, such as in USA, Europe and China. In this paper, the development stages of the study are presented, which include beginning stage, transitional stage and experimental stage. Based on the Einstein’s paper in 1905, the velocities greater than that of light had no possibility of existence. However, in the Einstein’s papers of 1907 it was founded that the superluminal signal speed could not be refuted absolutely. In this paper, the studies on velocities are classified. The definition of General Information Speed is suggested, which will ease the discussion. After reviewing the researches of 1962-2004, it can be concluded that the faster-than-light is a realizable scientific statement.
文摘As a leading global trade fair,ISPO MUNICH is on the most important industry and network platforms in the sports business:More than 2,700 exhibitors present trends and new products for the upcoming season each year in 16 halls.ISPO MUNICH 2018 will focus on major topics like digitalization,cross-industry,women in sports and sustainability.