A double thick GEM (THGEM) detector with thin THGEM foils and small holes was constructed. In order to optimize the operation parameters of the detector, a simulation study of the detector was carried out using ANSYS ...A double thick GEM (THGEM) detector with thin THGEM foils and small holes was constructed. In order to optimize the operation parameters of the detector, a simulation study of the detector was carried out using ANSYS and Garfield program. Some important characteristics, including primary electron transparency, avalanche development and the secondary electron loss were calculated. Parameters, such as electric field and gas choice were optimized.展开更多
A sealed high gas pressure detector working in pure argon is assembled.It consists of a 5 cm × 5 cm PCB THGEM(THick Gaseous Electron Multiplier).The detector structure and experimental setup are described.The p...A sealed high gas pressure detector working in pure argon is assembled.It consists of a 5 cm × 5 cm PCB THGEM(THick Gaseous Electron Multiplier).The detector structure and experimental setup are described.The performance under high pressure(2 atm) is examined,selecting optimal voltages for the ionization region and induction region.The dependence of the shape of alpha particle spectra measured with relative gas gain on gas pressure(1.3-2.0 atm) has been studied.Eight data sets of relative gas gain versus working voltage of THGEM,expressed by weighting field E/P,are normalized,consistent with theory.The results show that the air tightness of the chamber is good,measured by a sensitive barometer and checked with gas gain.The experimental results are compared with Monte Carlo simulation of energy deposition without gas gain involved.展开更多
In cases of high radiation emergencies,we propose a surface contamination monitor(SCM)that can quickly measure and pinpoint the contamination distribution in the affected population.Thick gaseous electron multiplier(T...In cases of high radiation emergencies,we propose a surface contamination monitor(SCM)that can quickly measure and pinpoint the contamination distribution in the affected population.Thick gaseous electron multiplier(THGEM)has several advantages,including fast response time and good spatial resolution.Based on new THGEMs,a two-dimensional imaging detector was developed for alpha detection,with a position resolution greater than 3 mm.The detector design and test results are described in this paper.Fast radiation imaging SCMs,with a 40mm×40 mm sensitive area,are currently under development.展开更多
This work shows the results of a streamer discharge mode studies in various gas detectors developed up-to-date. The results are based on a new experimental data from high-speed thin-gap gas detector application develo...This work shows the results of a streamer discharge mode studies in various gas detectors developed up-to-date. The results are based on a new experimental data from high-speed thin-gap gas detector application developments as well as on basic knowledge of multi-wire devices operations.展开更多
A new thermal neutron detector with a domestically produced THGEM (Thick Gas Electron Multiplier) was developed as an alternative to 3He to meet the needs of the next generation of neutron facilities. One type of Au...A new thermal neutron detector with a domestically produced THGEM (Thick Gas Electron Multiplier) was developed as an alternative to 3He to meet the needs of the next generation of neutron facilities. One type of Au-coated THGEM was designed specifically for neutron detection. A detector prototype has been developed and the preliminary experimental tests are presented, including the performance of the Au-coated THGEM working in At/CO2 gas mixtures and the neutron imaging test with 252 Cf source, which can provide the reference for experimental data for research in the future.展开更多
基金Supported by Fundamental Science on Nuclear Waste and Environmental Security Laboratory,Southwest University of Science and Technology. (Grant No.11zxnk03)
文摘A double thick GEM (THGEM) detector with thin THGEM foils and small holes was constructed. In order to optimize the operation parameters of the detector, a simulation study of the detector was carried out using ANSYS and Garfield program. Some important characteristics, including primary electron transparency, avalanche development and the secondary electron loss were calculated. Parameters, such as electric field and gas choice were optimized.
基金Supported by National Natural Science Foundation of China(11575193,11205240,11265003,U1431109)
文摘A sealed high gas pressure detector working in pure argon is assembled.It consists of a 5 cm × 5 cm PCB THGEM(THick Gaseous Electron Multiplier).The detector structure and experimental setup are described.The performance under high pressure(2 atm) is examined,selecting optimal voltages for the ionization region and induction region.The dependence of the shape of alpha particle spectra measured with relative gas gain on gas pressure(1.3-2.0 atm) has been studied.Eight data sets of relative gas gain versus working voltage of THGEM,expressed by weighting field E/P,are normalized,consistent with theory.The results show that the air tightness of the chamber is good,measured by a sensitive barometer and checked with gas gain.The experimental results are compared with Monte Carlo simulation of energy deposition without gas gain involved.
基金supported by the China Institute of Atomic Energy and University of Chinese Academy of SciencesNational Natural Science Foundation of China(Nos.11575193 and U1732266)+2 种基金Key Research Program of Frontier Sciences,CAS(No.QYZDB-SSWSLH039)the Youth Innovation Promotion Association of CAS(No.2016153)the Natural Science Key Foundation of Guangxi(No.2015GXNSFDA139002)
文摘In cases of high radiation emergencies,we propose a surface contamination monitor(SCM)that can quickly measure and pinpoint the contamination distribution in the affected population.Thick gaseous electron multiplier(THGEM)has several advantages,including fast response time and good spatial resolution.Based on new THGEMs,a two-dimensional imaging detector was developed for alpha detection,with a position resolution greater than 3 mm.The detector design and test results are described in this paper.Fast radiation imaging SCMs,with a 40mm×40 mm sensitive area,are currently under development.
文摘This work shows the results of a streamer discharge mode studies in various gas detectors developed up-to-date. The results are based on a new experimental data from high-speed thin-gap gas detector application developments as well as on basic knowledge of multi-wire devices operations.
基金Supported by National Natural Science Foundation of China(11127508,11175199)NPL,CAEP(2013DB06)State Key Laboratory of particle Detection and Electronics(H9294206TD)
文摘A new thermal neutron detector with a domestically produced THGEM (Thick Gas Electron Multiplier) was developed as an alternative to 3He to meet the needs of the next generation of neutron facilities. One type of Au-coated THGEM was designed specifically for neutron detection. A detector prototype has been developed and the preliminary experimental tests are presented, including the performance of the Au-coated THGEM working in At/CO2 gas mixtures and the neutron imaging test with 252 Cf source, which can provide the reference for experimental data for research in the future.