Objective To explore the causes and management of prosthesis disocation after artificaial hip replacement (AHR).Methods Seventeen patients with prosthesis dislocation after AHR during January 2000 to July 2010 were st...Objective To explore the causes and management of prosthesis disocation after artificaial hip replacement (AHR).Methods Seventeen patients with prosthesis dislocation after AHR during January 2000 to July 2010 were studied展开更多
Dislocations of total hip prostheses cause pain and patient dissatisfaction. Recurrent dislocations are difficult to treat mainly when the acetabular metal shell is well-fixed. The purpose of this article was to descr...Dislocations of total hip prostheses cause pain and patient dissatisfaction. Recurrent dislocations are difficult to treat mainly when the acetabular metal shell is well-fixed. The purpose of this article was to describe the surgical technique used for the treatment of a bilateral recurrent posterior dislocation after a cementless total hip prosthesis, caused by excessive inclination of acetabular components, in a 72-year-old patient. On both sides, acetabular metal shell, porouscoated, was well-fixed. Revision of the entire acetabular component could be an appropriate therapeutic option because it was malpositioned. Nevertheless, a conservative operation was performed. The metal shell was left in situ and the preexisting polyethylene liner was removed and replaced by a new undersized cross-linked polyethylene liner, then, cemented into the shell and properly oriented. An acetabular cemented augmentation reinforced by 3 cortical screws was associated with the reconstruction. This report suggests that cementation of new liner into a malpositioned well- fixed metal shell associated with an acetabular cemented augmentation is a simple and safe technique for the management of recurrent hip dislocation, for elderly patients in which it is advisable to avoid a major revision hip surgery by medical comorbidities. Nonetheless, further studies with medium-and long-term follow-up are needed to validate this technique.展开更多
Objective: To evaluate the outcome of total hip arthroplasty (THA) with cementless cups and femoral head autografts for patients with hip dysplasia and osteoarthritis. Methods: Between 1995 and 2002, we implanted 23 c...Objective: To evaluate the outcome of total hip arthroplasty (THA) with cementless cups and femoral head autografts for patients with hip dysplasia and osteoarthritis. Methods: Between 1995 and 2002, we implanted 23 cementless cups and femoral head autografts in 20 patients with hip dysplasia and osteoarthritis. In this study, a retrospective study was made on 21 hips in 20 patients (18 females and 2 males, aged 50 years on an average) with developmental hip dysplasia treated by THA with a cementless cup and femoral head autograft. The acetabular cup was placed at the level of the true acetabulum and all the patients required autogenous femoral head grafts due to acetabular deficiency. The average rate of the acetabular cup covered by the femoral head autograft was 31% (ranging from 10% to 45%). Eight hips had less than 25% cup coverage and thirteen between 25% and 50%. The average follow-up period was (4.7) years (range, 1-8 years). The replacing outcome was evaluated by modified Harris hip score. Preoperative and follow-up radiographs were made. Results: All the autografts were united to the host bones. No autograft was collapsed or no component from the hip was loosed in all the patients. According to the modified Harris hip score, the average hip score increased from 46 before operation to 89 at the final review. Before operation, the leg-length discrepancy was greater than 2 cm in all the patients except one with bilateral hip dysplasia. After operation, only 2 out of 20 patients had a leg-length discrepancy greater than 1 cm. Three hips showed minor bone resorption in the lateral portion of the graft, which did not support the cup. Three hips developed Grade 1 Brooker heterotopic ossification and one developed Grade 2. Conclusions: THA with a cementless cup and a femoral head autograft for patients with osteoarthritis resulted from hip dysplasia can result in favorable outcomes. This method can provide reliable acetabular fixation and restore the acetabular bone stock in patients with developmental hip dysplasia when the cementless cup covered by the graft does not exceed 50%.展开更多
全髋关节置换术(total hip arthroplasty,THA)治疗终末期骨性关节炎及股骨头坏死等髋关节疾病有着较为显著的疗效,髋臼假体的准确定位成为手术的关键,诸多学者提出以髋臼横韧带为参考定位髋臼假体能降低术后脱位的发生率,这种定位方法...全髋关节置换术(total hip arthroplasty,THA)治疗终末期骨性关节炎及股骨头坏死等髋关节疾病有着较为显著的疗效,髋臼假体的准确定位成为手术的关键,诸多学者提出以髋臼横韧带为参考定位髋臼假体能降低术后脱位的发生率,这种定位方法无需额外器械辅助,具有简便、快速、经济的优点,能够避免高BMI及术中骨盆旋转对假体安置的影响,帮助初学者快速掌握全髋关节置换术中髋臼假体安置的技术要领。本文将阐述髋臼横韧带的基础解剖,并从髋臼假体的角度、覆盖率及旋转中心等方面对髋臼横韧带在全髋关节置换术中对髋臼假体的定位意义进行综述。展开更多
文摘Objective To explore the causes and management of prosthesis disocation after artificaial hip replacement (AHR).Methods Seventeen patients with prosthesis dislocation after AHR during January 2000 to July 2010 were studied
文摘Dislocations of total hip prostheses cause pain and patient dissatisfaction. Recurrent dislocations are difficult to treat mainly when the acetabular metal shell is well-fixed. The purpose of this article was to describe the surgical technique used for the treatment of a bilateral recurrent posterior dislocation after a cementless total hip prosthesis, caused by excessive inclination of acetabular components, in a 72-year-old patient. On both sides, acetabular metal shell, porouscoated, was well-fixed. Revision of the entire acetabular component could be an appropriate therapeutic option because it was malpositioned. Nevertheless, a conservative operation was performed. The metal shell was left in situ and the preexisting polyethylene liner was removed and replaced by a new undersized cross-linked polyethylene liner, then, cemented into the shell and properly oriented. An acetabular cemented augmentation reinforced by 3 cortical screws was associated with the reconstruction. This report suggests that cementation of new liner into a malpositioned well- fixed metal shell associated with an acetabular cemented augmentation is a simple and safe technique for the management of recurrent hip dislocation, for elderly patients in which it is advisable to avoid a major revision hip surgery by medical comorbidities. Nonetheless, further studies with medium-and long-term follow-up are needed to validate this technique.
文摘Objective: To evaluate the outcome of total hip arthroplasty (THA) with cementless cups and femoral head autografts for patients with hip dysplasia and osteoarthritis. Methods: Between 1995 and 2002, we implanted 23 cementless cups and femoral head autografts in 20 patients with hip dysplasia and osteoarthritis. In this study, a retrospective study was made on 21 hips in 20 patients (18 females and 2 males, aged 50 years on an average) with developmental hip dysplasia treated by THA with a cementless cup and femoral head autograft. The acetabular cup was placed at the level of the true acetabulum and all the patients required autogenous femoral head grafts due to acetabular deficiency. The average rate of the acetabular cup covered by the femoral head autograft was 31% (ranging from 10% to 45%). Eight hips had less than 25% cup coverage and thirteen between 25% and 50%. The average follow-up period was (4.7) years (range, 1-8 years). The replacing outcome was evaluated by modified Harris hip score. Preoperative and follow-up radiographs were made. Results: All the autografts were united to the host bones. No autograft was collapsed or no component from the hip was loosed in all the patients. According to the modified Harris hip score, the average hip score increased from 46 before operation to 89 at the final review. Before operation, the leg-length discrepancy was greater than 2 cm in all the patients except one with bilateral hip dysplasia. After operation, only 2 out of 20 patients had a leg-length discrepancy greater than 1 cm. Three hips showed minor bone resorption in the lateral portion of the graft, which did not support the cup. Three hips developed Grade 1 Brooker heterotopic ossification and one developed Grade 2. Conclusions: THA with a cementless cup and a femoral head autograft for patients with osteoarthritis resulted from hip dysplasia can result in favorable outcomes. This method can provide reliable acetabular fixation and restore the acetabular bone stock in patients with developmental hip dysplasia when the cementless cup covered by the graft does not exceed 50%.
文摘全髋关节置换术(total hip arthroplasty,THA)治疗终末期骨性关节炎及股骨头坏死等髋关节疾病有着较为显著的疗效,髋臼假体的准确定位成为手术的关键,诸多学者提出以髋臼横韧带为参考定位髋臼假体能降低术后脱位的发生率,这种定位方法无需额外器械辅助,具有简便、快速、经济的优点,能够避免高BMI及术中骨盆旋转对假体安置的影响,帮助初学者快速掌握全髋关节置换术中髋臼假体安置的技术要领。本文将阐述髋臼横韧带的基础解剖,并从髋臼假体的角度、覆盖率及旋转中心等方面对髋臼横韧带在全髋关节置换术中对髋臼假体的定位意义进行综述。