The Cloud Profiling Radar (CPR) onboard CloudSat is an active sensor specifically dedicated to cloud detection. Compared to passive remote sensors, CPR plays a unique role in investigating the occurrence of multi-la...The Cloud Profiling Radar (CPR) onboard CloudSat is an active sensor specifically dedicated to cloud detection. Compared to passive remote sensors, CPR plays a unique role in investigating the occurrence of multi-layer clouds and depicting the internal vertical structure of clouds. However, owing to contamination from ground clutter, CPR reflectivity signals are invalid in the lowest 1 km above the surface, leading to numerous missed detections of warm clouds. In this study, by using 1-yr CPR and MODIS (Moderate Resolution Imaging Spectroradiometer) synchronous data, those CPR-missed oceanic warm clouds that are identified as cloudy by MODIS are examined. It is demonstrated that CPR severely underestimates the occurrence of oceanic warm clouds, with a global-average miss rate of about 0.43. Over the tropical and subtropical oceans, the CPR-missed clouds tend to occur in regions with relatively low sea surface temperature. CPR misses almost all warm clouds with cloud tops lower than 1 km, and the miss rate reduces with increasing cloud top. As for clouds with cloud tops higher than 2 kin, the negative bias of CPR-captured warm cloud occurrence falls below 3%. The cloud top height of CPR-missed warm clouds ranges from 0.6 to 1.2 kin, and these clouds mostly have evidently small optical depths and droplet effective radii. The vertically integrated cloud liquid water content of CPR-missed warm clouds is smaller than 50 g m 2 It is also revealed that CPR misses some warm clouds that have small optical depths or small droplet sizes, besides those limited in the boundary layer below about 1 km due to ground clutter.展开更多
FMCW Radar (Frequency Modulated Continuous Wave Radar) is used for various purposes, such as atmospheric Remote Sensing, inter-vehicle ranging, etc. FMCW radar systems are usually very compact, relatively cheap in pur...FMCW Radar (Frequency Modulated Continuous Wave Radar) is used for various purposes, such as atmospheric Remote Sensing, inter-vehicle ranging, etc. FMCW radar systems are usually very compact, relatively cheap in purchase as well as in daily use, and consume little power. In this paper, FMCW radar determines a target range by measuring the beat frequency between a transmitted signal and the received signal from the target, and Combines between PO and radar single. The approach based on frequency domain physical optics for the scattering estimation and the linear system modeling for the estimation of time domain response, and FMCW Radar signal processing.展开更多
文摘地基云雷达是云的重要探测手段,但随着运行时间的增加,雷达发射机、接收器等参数的变化,会使观测数据产生漂移偏差,从而对云物理特性的反演产生显著影响,因此云雷达数据的校准是一个重要的基础问题。针对KAZR(Ka-Band Zenith Radar,K波段云雷达)云雷达特征,本文在Pavlos等提出的雷达数据校准方法基础上进行改进,优化了对弱云和降水的信号识别,利用CloudSat星载雷达观测的反射率因子,气体衰减校正等数据,对兰州大学半干旱气候环境监测站(Semi-Arid Climate and Environment Observatory of Lanzhou University,SACOL)KAZR云雷达2013年8月至2017年5月反射率因子数据进行了校准,建立了KAZR雷达反射率因子46个月的历史资料校准数据库,并对校准周期的变化进行了对比分析。校准数据库的建立对SACOL站云的长期观测研究具有重要意义,同时为不同波段地基雷达的对比增加了可行性。
基金Supported by the National Natural Science Foundation of China(41175032)
文摘The Cloud Profiling Radar (CPR) onboard CloudSat is an active sensor specifically dedicated to cloud detection. Compared to passive remote sensors, CPR plays a unique role in investigating the occurrence of multi-layer clouds and depicting the internal vertical structure of clouds. However, owing to contamination from ground clutter, CPR reflectivity signals are invalid in the lowest 1 km above the surface, leading to numerous missed detections of warm clouds. In this study, by using 1-yr CPR and MODIS (Moderate Resolution Imaging Spectroradiometer) synchronous data, those CPR-missed oceanic warm clouds that are identified as cloudy by MODIS are examined. It is demonstrated that CPR severely underestimates the occurrence of oceanic warm clouds, with a global-average miss rate of about 0.43. Over the tropical and subtropical oceans, the CPR-missed clouds tend to occur in regions with relatively low sea surface temperature. CPR misses almost all warm clouds with cloud tops lower than 1 km, and the miss rate reduces with increasing cloud top. As for clouds with cloud tops higher than 2 kin, the negative bias of CPR-captured warm cloud occurrence falls below 3%. The cloud top height of CPR-missed warm clouds ranges from 0.6 to 1.2 kin, and these clouds mostly have evidently small optical depths and droplet effective radii. The vertically integrated cloud liquid water content of CPR-missed warm clouds is smaller than 50 g m 2 It is also revealed that CPR misses some warm clouds that have small optical depths or small droplet sizes, besides those limited in the boundary layer below about 1 km due to ground clutter.
文摘FMCW Radar (Frequency Modulated Continuous Wave Radar) is used for various purposes, such as atmospheric Remote Sensing, inter-vehicle ranging, etc. FMCW radar systems are usually very compact, relatively cheap in purchase as well as in daily use, and consume little power. In this paper, FMCW radar determines a target range by measuring the beat frequency between a transmitted signal and the received signal from the target, and Combines between PO and radar single. The approach based on frequency domain physical optics for the scattering estimation and the linear system modeling for the estimation of time domain response, and FMCW Radar signal processing.