Comparison of intraocular pressure measurements with different contact tonometers in young healthy persons 被引量:2
1
作者 saulius galgauskas rasa strupaite +1 位作者 ernesta strelkauskaite rimvydas asoklis 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2016年第1期76-80,共5页
AIM:To analyze the correlation of Goldmann applanation tonometer(GAT),I-Care tonometer and Tono-Pen tonometer results in young healthy persons,and to investigate the influence of central corneal thickness(CCT)on ... AIM:To analyze the correlation of Goldmann applanation tonometer(GAT),I-Care tonometer and Tono-Pen tonometer results in young healthy persons,and to investigate the influence of central corneal thickness(CCT)on intraocular pressure(IOP)measurements recorded with these tonometers.·M ETHODS:We conducted a pilot clinical study in 78eyes of 78 subjects aged 22-28 years old(44 women and34 men;mean age 23.8±1.19y).IOP was measured using GAT,I-Care and Tono-Pen tonometers,followed by measurements of CCT.Statistical analysis was performed using SPSS 20.0.·RESULTS:The mean IOPs and standard deviation(±SD)for GAT,I-Care and Tono-Pen were 15.62±2.281 mm Hg,16.29±2.726 mm Hg and 16.32±2.393 mm Hg,respectively.The mean CCT was 555.15±29.648μm.Clear positive correlations between GAT and I-Care,GAT and TonoPen,and I-Care and Tono-Pen tonometers were found(=0.867,〈0.001;=0.861,〈0.001;=0.915,〈0.001,respectively).In comparison between devices,BlandAltman analysis showed a significant mean difference(MD)in the measurements by GAT and I-Care of-0.679 mm Hg and by GAT and Tono-Pen of-0.705 mm Hg(〈0.001),but there was no significant difference between I-Care and Tono-Pe(〉0.05).Both non-gold standard tonometers were affected by CCT;that is,both I-Care and Tono-Pen tonometer values were significantly higher with higher CCT means(〉555μm;MD=-1.282,〈0.001;MD=-0.949,〈0.001,respectively)compared with GAT.·CONCLUSION:Both I-Care and Tono-Pen tonometers overestimated IOP compared with the GAT values.Either the I-Care or Tono-Pen tonometer could be used instead of GAT because there was no significant difference between their results.Higher CCT values(〉555μm)were associated with overestimated IOP values. 展开更多
关键词 Goldmann tonometer I-Care tonometer tono-Pen tonometer comeal thickness intraocular pressure
下载PDF
Tono-Pen眼压计对兔眼不同部位眼压测量值的相关性研究 被引量:6
2
作者 张虹 李贵刚 +3 位作者 胡军 胡维琨 孙旭芳 赵春明 《眼科新进展》 CAS 2006年第10期744-746,共3页
目的研究兔眼球不同部位测量眼压(intraocular pressure,IOP)值的相关性规律。方法采用Tono-Pen眼压计全身麻醉下测量40只新西兰白兔角膜中央、旁中央区、角膜缘及巩膜部位IOP值,同时采用Schiotz眼压计测量角膜中央IOP值。采用SPSS软件... 目的研究兔眼球不同部位测量眼压(intraocular pressure,IOP)值的相关性规律。方法采用Tono-Pen眼压计全身麻醉下测量40只新西兰白兔角膜中央、旁中央区、角膜缘及巩膜部位IOP值,同时采用Schiotz眼压计测量角膜中央IOP值。采用SPSS软件分析不同部位IOP测量值间的相关性。结果兔角膜中央区、旁中央区、角膜缘及角膜缘后4mm巩膜部位IOP值分别为(19.44±2.33)mmHg(1kPa=7.5mmHg)、(19.44±1.95)mmHg、(21.66±4.26)mmHg和(21.83±4.84)mmHg,Schiotz眼压计测量角膜中央IOP值(19.27±3.14)mmHg。角膜旁中央区与角膜中央区IOP值有相关性,检验有统计学意义(R=0.615,P=0.007<0.01),而角膜缘、角膜缘后4mm巩膜与角膜中央区IOP值相关系数及P值分别为0.537/0.021、0.215/0.391。结论采用Tono-Pen眼压计测量兔眼角膜旁中央区或角膜缘眼压可以反映眼压实际值。 展开更多
关键词 tono-PEN眼压计 眼压
下载PDF
Tono-Pen眼压计测量人角膜不同部位眼压的比较 被引量:5
3
作者 李新宇 栗静 +1 位作者 刘磊 汪明红 《国际眼科杂志》 CAS 2008年第1期76-77,共2页
目的:用Tono-Pen眼压计测量人眼角膜中央、旁中央、角巩缘部位眼压值,比较不同部位值的差异及相关性。方法:正常角膜用Tono-Pen眼压计依次测量角膜中心、旁中心、角膜缘眼压值,方差分析不同部位眼压的差异,分析结果的相关性。结果:Tono-... 目的:用Tono-Pen眼压计测量人眼角膜中央、旁中央、角巩缘部位眼压值,比较不同部位值的差异及相关性。方法:正常角膜用Tono-Pen眼压计依次测量角膜中心、旁中心、角膜缘眼压值,方差分析不同部位眼压的差异,分析结果的相关性。结果:Tono-Pen眼压计检测得出的眼压平均值角膜中央为16.28±2.73mmHg,旁中央为16.33±2.69mmHg,角巩缘为16.58±2.58mmHg.角膜中心与旁中心的相关系数r=0.966,P=0.000,角膜中心与角膜缘的相关系数为r=0.897,P=0.000,角膜旁中心与角膜缘的相关系数为r=0.910,P=0.000。不同部位眼压值差异没有显著性(F=0.093,P=0.913>0.05)。结论:不同部位眼压值密切相关,差异没有统计学意义。Tono-Pen眼压计测量不同部位眼压均可取得较为一致的结果。 展开更多
关键词 tono-PEN眼压计 角膜 眼压
下载PDF
治疗性角膜接触镜对Tono-pen眼压计测量角膜病变患者眼压的影响 被引量:3
4
作者 王忠浩 梁轩伟 +3 位作者 曾阳发 杨晓 蔡小于 刘杏 《中山大学学报(医学科学版)》 CAS CSCD 北大核心 2014年第1期100-104,共5页
[目的]比较配戴治疗性角膜接触镜(TCL)前后Tono-pen眼压计测量角膜病变患者眼压测量的差异,分析治疗性角膜接触对Tono-pen眼压计测量值的影响.[方法]连续纳入2012年4月至2012年10月我院就诊的33例(33眼)角膜病变患者,包括大泡性角... [目的]比较配戴治疗性角膜接触镜(TCL)前后Tono-pen眼压计测量角膜病变患者眼压测量的差异,分析治疗性角膜接触对Tono-pen眼压计测量值的影响.[方法]连续纳入2012年4月至2012年10月我院就诊的33例(33眼)角膜病变患者,包括大泡性角膜病变11眼、眼化学伤8眼、单疱病毒性角膜炎5眼、继发性青光眼4眼、前部角膜营养不良2眼、穿透性角膜移植术后2眼、复发性胬肉l眼.应用Tono-pen眼压计测量患者未配戴TCL和配戴TCL两种状态下的眼压,每种测量方式各重复测2次.用组内相关系数ICC计算每一种测量方法的重复性,计算重复测量间差异的95%可信限;配对t检验比较两种眼压测量方法的差异,计算差异的可信限95%LoA,并绘制Bland-Altman散点图.[结果]Tono-pen眼压计直接重复测量的ICC为0.986,两次测量的平均差值为(0.42± 1.98) mmHg,95%可信限为-4.30 ~ 3.46 mmHg,其中90.9%的测量差值≤3 mmHg;配戴治疗性角膜接触镜后重复测量的ICC为0.983,两次测量的平均差值为(0.12±2.19)mmHg,95%可信限为-4.46 ~ 4.22 mmHg,90.9%的测量差值≤3 mmHg.配戴治疗性角膜接触镜后Tono-pen眼压测量值平均减小(0.68±3.39)mmHg,差异无统计学意义(P=0.257),两种测量结果的一致性系数ICC为0.959,差值的95%可信限为-7.32~5.96 mmHg,其中70%测量的差值≤3 mmHg;在平均眼压<21 mmHg的患者中,82.4%的测量差值≤3 mmHg,在平均眼压≥21 mmHg的患者中,56.3%的测量差值≤3 mmHg.[结论]Tono-pen眼压计测量角膜病变患者的眼压有较好的重复性,配戴治疗性角膜接触镜对测量的重复性和总体的测量均值无影响.但配戴角膜接触镜前后眼压测量值存在一定程度的差异,高眼压者比正常眼压者的差异大,临床应用时应对测量结果进行客观的评价. 展开更多
关键词 眼压 tono-PEN眼压计 治疗性角膜接触镜 角膜病变
下载PDF
Tono-pen眼压计的可重复性和准确性研究 被引量:3
5
作者 傅方 陈晓明 +1 位作者 沈建通 周荣乐 《眼科新进展》 CAS 北大核心 2011年第1期78-80,共3页
目的通过比较反复测量所得的眼压值,了解Tono-pen眼压计测量眼压的可重复性和准确性。方法选取眼科门诊就诊的84例患者和健康体检者2名共150眼纳入研究。由2名检查者先后用Tono-pen眼压计和Goldmann眼压计进行3次连续测量。按照Goldman... 目的通过比较反复测量所得的眼压值,了解Tono-pen眼压计测量眼压的可重复性和准确性。方法选取眼科门诊就诊的84例患者和健康体检者2名共150眼纳入研究。由2名检查者先后用Tono-pen眼压计和Goldmann眼压计进行3次连续测量。按照Goldmann眼压计测量值从低到高将研究对象分为A、B、C3组:A组(低眼压组)IOP〈11mmHg(1kPa=7.5mmHg),B组(正常眼压组)IOP为11~21mmHg,C组(高眼压组)IOP〉21mmHg。分组分析Tono-pen眼压计组内(检查者甲3次测量值之间)可重复性和组间(2名检查者之间)可重复性。以Goldmann眼压计为标准评价Tono-pen眼压计的准确性。结果组内可重复性:Tono-pen眼压计反复测量差值平均值A组(1.533±1.008)mmHg,B组(1.673±1.123)mmHg,C组(3.474±2.695)mmHg。组间可重复性:以2名检查者的测量平均值进行比较。Tono-pen眼压计组间相差范围:A组0.25~1.77mmHg,B组0.40~0.73mmHg,C组0.07~0.83mmHg。与Gold-mann眼压计测量值比较,A组Tono-pen眼压计平均偏低估计眼压0.87mmHg(0.02~1.71mmHg,P=0.045),B组2种测量手段所得结果无差异(P=0.845),C组Tono-pen眼压计平均偏低估计眼压5.76mmHg(2.30~9.21mmHg,P=0.003)。结论对于正常眼压范围的个体,Tono-pen眼压计测量值与Goldmann眼压计测量值相当,但对于低眼压或高眼压眼,Tono-pen眼压计测量值均比Goldmann眼压计测量值偏低。 展开更多
关键词 tono-PEN眼压计 GOLDMANN眼压计 可重复性 准确性
下载PDF
眼球不同部位Tono-Pen眼压计测量结果比较 被引量:2
6
作者 马恩普 郝燕燕 《郑州大学学报(医学版)》 CAS 北大核心 2006年第1期150-151,共2页
目的:用Tono-Pen眼压计测量眼球各部位眼压值。方法:正常人及无角膜病变的青光眼患者61例99眼,用Tono-Pen眼压计依次测量角膜中心、角膜缘及颞上侧角膜缘后4mm巩膜壁眼压值。结果:角膜中心眼压为(2.52±0.74)kPa,角膜缘为(2.63±... 目的:用Tono-Pen眼压计测量眼球各部位眼压值。方法:正常人及无角膜病变的青光眼患者61例99眼,用Tono-Pen眼压计依次测量角膜中心、角膜缘及颞上侧角膜缘后4mm巩膜壁眼压值。结果:角膜中心眼压为(2.52±0.74)kPa,角膜缘为(2.63±0.79)kPa,巩膜壁为(4.46±1.49)kPa。角膜中心和角膜缘眼压差异无统计学意义,而巩膜壁眼压高于角膜中心。角膜中心及巩膜壁眼压呈正相关(r=0.542,P=0.000)。以Y为角膜中心眼压值,X为巩膜壁眼压值,则当X≤2.793kPa,直线回归方程为Y=1.824+0.104X;当X>2.793kPa(高眼压)时,Y=1.493+0.359X。结论:使用Tono-Pen眼压计测量眼压时,巩膜壁眼压值可为真实眼压值提供可靠参考;角膜任何部位均可测得准确眼压值。 展开更多
关键词 tono—Pen眼压计 眼压 巩膜壁 角膜中心 角膜缘
下载PDF
应用Tono-pen眼压计测量正常人24 h眼压的临床研究 被引量:3
7
作者 张金顺 彭寿雄 +2 位作者 林明楷 方爱武 杜驰 《眼视光学杂志》 2006年第4期233-235,共3页
目的研究正常人24h眼压的变动规律。方法选择年龄为30~60岁的正常志愿者30人(60眼),应用Tono-pen眼压计进行24h的眼压测量。测量自清晨7:00开始至第二天清晨7:00,每2h测一次眼压,共测12次。在7:00—23:00时间段中,测受检者... 目的研究正常人24h眼压的变动规律。方法选择年龄为30~60岁的正常志愿者30人(60眼),应用Tono-pen眼压计进行24h的眼压测量。测量自清晨7:00开始至第二天清晨7:00,每2h测一次眼压,共测12次。在7:00—23:00时间段中,测受检者的坐位眼压和卧位眼压。在23:00—07:00时间段,测受检者的平卧位眼压。结果志愿者眼压高峰出现在1:30,眼压低谷出现在17:30,24h坐、卧位眼压变动幅度大于24h卧位眼压变动幅度。结论正常人的眼压高峰大多出现在夜间睡眠时间,测受检者的坐、卧位眼压是一种较好的24h眼压测量方法。 展开更多
关键词 眼内压 体位 昼夜变动节律 tono—pen眼压计
下载PDF
Tono-Pen眼压计与Goldmann眼压计的临床比较 被引量:6
8
作者 江冰 蒋幼芹 《眼科学报》 2002年第4期226-229,共4页
目的:了解Tono-Pen眼压计的临床实用性。方法:62例(111只眼)随机先后用Tono-Pen眼压计与Goldmann眼压计进行眼压测量,比较两种眼压计测量值的差异。结果:111只眼中,用Goldmann眼压计测量的眼压平均值为(15.82±4.88)mmHg,用Tono-Pe... 目的:了解Tono-Pen眼压计的临床实用性。方法:62例(111只眼)随机先后用Tono-Pen眼压计与Goldmann眼压计进行眼压测量,比较两种眼压计测量值的差异。结果:111只眼中,用Goldmann眼压计测量的眼压平均值为(15.82±4.88)mmHg,用Tono-Pen眼压计测量的眼压平均值为(16.34±4.33)mmHg,两者有显著性差异。眼压在9~30mmHg范围时,两种眼压计的测量值之差为(-0.51±2.24)mmHg,差异无显著性。在眼压低于9mmHg时,有过高估计眼压的趋向;在眼压高于30mmHg时,有过低估计眼压的趋向。Tono-Pen眼压计与Goldmann眼压计的相关系数为0.865,呈密切相关。结论:Tono-Pen眼压计与Goldmann眼压计有很好的相关性,尤其是在眼压为9~30mmHg范围。眼科学报 2002;18:226-229. 展开更多
关键词 眼压 tono-PEN眼压计 GOLDMANN眼压计 比较分析
下载PDF
Tono-Pen眼压计在围术期的应用
9
作者 蒋忠 马正良 《医疗卫生装备》 CAS 2009年第12期76-77,共2页
目的:使用Tono-Pen眼压计对术中眼内压进行监测。方法:选择16例妇科腹腔镜手术病例,分别于不同时点使用Tono-Pen眼压计监测眼内压,将所得结果进行统计学分析。结果:随着头低位和人工气腹时间的延长,患者眼内压进行性升高,人工气腹结束... 目的:使用Tono-Pen眼压计对术中眼内压进行监测。方法:选择16例妇科腹腔镜手术病例,分别于不同时点使用Tono-Pen眼压计监测眼内压,将所得结果进行统计学分析。结果:随着头低位和人工气腹时间的延长,患者眼内压进行性升高,人工气腹结束恢复平卧位后,眼内压迅速恢复到术前水平。结论:Tono-Pen眼压计目前是唯一可用于全身麻醉状态下的眼压计,为做好围术期视力保护工作,应重视Tono-Pen眼压计在术中的推广应用,防止视力损害事件的发生。 展开更多
关键词 tono—Pen眼压计 眼内压 视力损害
下载PDF
Tono-pen眼压计与Goldmann眼压计对穿透性小梁切除术后患者眼压测量的比较 被引量:12
10
作者 韩英军 梁天蔚 +7 位作者 勇志鹏 张满红 李文芳 胡利华 王立华 陈建丽 王婕 孙挥宇 《国际眼科杂志》 CAS 2006年第6期1424-1426,共3页
目的:寻找穿透性小梁切除术后患者眼压测量的简单方法。方法:随机选取行穿透性小梁切除术后3d的患者120例120眼。分别用Goldmann眼压计和Tono-pen眼压计测量眼压,比较两种眼压测量值的差异。结果:120眼中,Goldmann眼压计所测量眼压的平... 目的:寻找穿透性小梁切除术后患者眼压测量的简单方法。方法:随机选取行穿透性小梁切除术后3d的患者120例120眼。分别用Goldmann眼压计和Tono-pen眼压计测量眼压,比较两种眼压测量值的差异。结果:120眼中,Goldmann眼压计所测量眼压的平均数值14.69±4.60mmHg。Tono-pen所测眼压的平均数值14.72±4.62mmHg。经统计学检验,P>0.05,Tono-pen眼压计与Goldman眼压计的测量结果无显著性差异。对于穿透性小梁切除术后的眼压测量,Tonopen眼压计与Goldman眼压计的测量结果有高度相关性。Tono-pen眼压计可以准确地估计眼压值。结论:对于穿透性小梁切除术后的的患者眼压在7~32mmHg间时Tono-pen眼压计可以作为一种准确测量眼压的简单方法。 展开更多
关键词 穿透性小梁切除术 眼压 tono—pen眼压计 GOLDMANN眼压计
下载PDF
Levels of Agricultural Pesticides in Sediments and Irrigation Water from Tono and Vea in the Upper East of Ghana 被引量:1
11
作者 Kenneth B. Pelig-Ba 《Journal of Environmental Protection》 2011年第6期761-768,共8页
Water and sediment samples were taken from selected irrigation dams located at Tono and Vea in the Upper East Region of Ghana and analyzed for organic pesticides using gas chromatography. Sixteen organic residues were... Water and sediment samples were taken from selected irrigation dams located at Tono and Vea in the Upper East Region of Ghana and analyzed for organic pesticides using gas chromatography. Sixteen organic residues were identified of which thirteen had at least some trace concentrations ranging from 0.001 to 25.4 μg/L. It was found in the laboratory that the concentrations of DDT, BHC and heptachlor were above the upper limited recommended by WHO and the concentrations of DDT in both reservoirs were higher than 20 times the recommended limits. High concentrations of DDT were found in the water samples while the other two residues were identified in the sediments. The high DDT concentration in water was due to 1) the initial amount of DDT applied and the period in the reservoirs, 2) a half-life of 350 days suggested that much of the DDT originally used was not destroyed if applied less than this period, 3) its low solubility in water did not allow for dissolution and subsequent dispersal in water;4) the indiscriminate uses of DDT for fishing as confirmed by the local people The high DDT level suggested that the water is not safe for many aquatic organisms and even humans. Generally the levels of these organic residues suggested that the dams have been polluted due to human activities such as farming and the unorthodox method of fishing. Therefore, steps should be taken to reduce the levels of DDT concentrations to preserve the aquatic life in the dams. 展开更多
关键词 PESTICIDES SEDIMENTS IRRIGATION DAMS tono Vea
下载PDF
Tono-pen measurement of intraocular pressure under topical anaesthesia in full term normal newborns 被引量:1
12
作者 Sagili Chandrasekhara Reddy Rosnita Alias 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2014年第1期92-94,共3页
AIM: Tono-pen measurement of intraocular pressure(IOP) under topical anaesthesia in full term normal newborns. ·METHODS: The IOP measurements were taken using Tono-pen XL tonometer under topical anaesthesia in 15... AIM: Tono-pen measurement of intraocular pressure(IOP) under topical anaesthesia in full term normal newborns. ·METHODS: The IOP measurements were taken using Tono-pen XL tonometer under topical anaesthesia in 150 newborns(300 eyes) within 24h after birth,over a period of three months,in a university hospital. Gender,gestation period,mode of delivery and birth weight of newborns were noted from medical records. ·RESULTS: There were 70 males and 80 females. All babies were Malays. The IOP measurements were taken between 12 and 24h after birth. The gestation period of babies ranged between 37 and 41 weeks; 118 babies were delivered by spontaneous vaginal delivery and 32 by caesarian section. The birth weight of babies ranged between 2.1 and 4.3kg. The mean IOP of 300 eyes was 15.99±2.79mmHg(range 8-22). There was no statistically significant difference of mean IOP and gender,laterality of eye,type of delivery,gestation age,or birth weight of newborns. ·CONCLUSION: The IOP in full term normal newborns was 16mmHg. Tono-Pen appears to be ideal instrument for taking IOP in newborns because of its small size and easy handling. 展开更多
关键词 intraocular pressure NEWBORN tono-pen
下载PDF
Comparison of Intraocular Pressures at Different Points in Human's Cornea before and after Laser in situ Keratomileusis with Tono-Pen Tonometer 被引量:1
13
作者 李新宇 李贵刚 +1 位作者 刘磊 栗静 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2011年第1期128-130,共3页
In order to explore the difference of intraocular pressure(IOP) at different points of cornea before and after laser in situ keratomileusis(LASIK),IOP was measured by Tono-Pen Tonometer at central cornea,pericentr... In order to explore the difference of intraocular pressure(IOP) at different points of cornea before and after laser in situ keratomileusis(LASIK),IOP was measured by Tono-Pen Tonometer at central cornea,pericentral cornea and limbus respectively and analyzed statistically.After LASIK,IOP was dropped significantly at central cornea and pericentral cornea(P〈0.05),while no statistically significant change occurred at limbus(P〉0.05).There was no statistically significant difference in IOP at different points before LASIK(F=0.110,P=0.896),but statistically significant difference was found after LASIK(F=7.375,P=0.001).It was suggested that reliable IOP after LASIK could be obtained from the limbus by Tono-Pen tonometer. 展开更多
关键词 tono-Pen tonorneter laser in situ keratomileusis CORNEA intraocular pressure
下载PDF
Tono-Pen眼压计对兔眼不同部位眼压测量值的相关性研究(英文)
14
作者 李贵刚 张虹 《眼视光学杂志》 2007年第4期225-227,共3页
目的研究兔眼球不同部位眼压测量值的相关性规律。方法采用Tono-pen眼压计在全身麻醉下测量40只新西兰白兔角膜中央、旁中央区、角膜缘及巩膜部位眼压值,同时采用Schitz眼压计测量角膜中央眼压值。采用SPSS软件分析不同部位眼压测量... 目的研究兔眼球不同部位眼压测量值的相关性规律。方法采用Tono-pen眼压计在全身麻醉下测量40只新西兰白兔角膜中央、旁中央区、角膜缘及巩膜部位眼压值,同时采用Schitz眼压计测量角膜中央眼压值。采用SPSS软件分析不同部位眼压测量值间的相关性。结果兔角膜中央区、旁中央区、角膜缘及角膜缘后4mm巩膜部位眼压值分别为(19.44±2.33)mmHg、(19.44±1.95)mmHg、(21.66±4.26)mmHg和(21.83±4.84)mmHg,Schitz眼压计测量角膜中央眼压值为(19.27±3.14)mmHg。角膜旁中央区与角膜中央区眼压值有相关性,检验有统计学意义(r=0.615,P=0.007),而角膜缘、角膜缘后4mm巩膜与角膜中央区眼压值相关系数r及P值分别为0.537/0.021,0.215/0.391。结论采用Tono-Pen眼压计测量兔眼角膜旁中央区或角膜缘眼压可以反映眼压实际值。 展开更多
关键词 tono—Pen眼压计 眼压 相关性
下载PDF
Tono-Pen眼压计临床应用评价 被引量:12
15
作者 乔荣华 刘丽娜 +1 位作者 李美玉 任泽钦 《中国实用眼科杂志》 CSCD 北大核心 2004年第12期980-982,共3页
目的 评价Tono -Pen眼压计的临床应用价值。方法  93例青光眼患者的 93眼纳入本研究 ,分别进行了Goldmann眼压计和Tono -Pen眼压计的测量。对两种眼压计的测量结果进行比较并评价Tono -Pen眼压计的特异度与灵敏度。结果 两种眼压计... 目的 评价Tono -Pen眼压计的临床应用价值。方法  93例青光眼患者的 93眼纳入本研究 ,分别进行了Goldmann眼压计和Tono -Pen眼压计的测量。对两种眼压计的测量结果进行比较并评价Tono -Pen眼压计的特异度与灵敏度。结果 两种眼压计测量值相差范围 -12~ 8mmHg ,差值的绝对值≤ 2mmHg占 61 3 % ,≤ 3mmHg为 75 3 % ,≥ 7mmHg者 5 4% ,总体相关系数 0 944(P <0 0 0 1) ,眼压≤ 2 1mmHg ,Tono -Pen眼压计偏高估计眼压 0 70± 2 3 1mmHg (P <0 0 5 ) ,2 2~3 0mmHg ,Tono -Pen眼压计偏低估计眼压 1 71± 3 15mmHg (P <0 0 5 ) ,>3 0mmHg ,两种测量手段所得结果无差异 (P >0 0 5 )。Tono -Pen眼压计的特异度与灵敏度分别为 93 6%和 84 8%。结论Tono -Pen眼压计可用于青光眼的筛查 ,但不适合用于其诊断和随访。 展开更多
关键词 眼压计 特异度 临床应用评价 诊断 临床应用价值 青光眼患者 合用 测量手段 绝对值 结论
原文传递
EDC指征微污染有机物和亚硝胺副产物去除效能
16
作者 宋阳 彭健珊 +3 位作者 李凯 秦雯 王志红 刘立凡 《环境科学与技术》 CAS CSCD 北大核心 2023年第3期168-177,共10页
在臭氧氧化含有不同反应活性的微污染有机物腐殖酸配水和实际水过程中,该文考察紫外吸收(UV_(254))、供电子能力(EDC)的相对剩余量与微污染有机物和亚硝胺消毒副产物的去除效能的关系。UV_(254)、EDC、微污染有机物、N-二甲基亚硝胺(ND... 在臭氧氧化含有不同反应活性的微污染有机物腐殖酸配水和实际水过程中,该文考察紫外吸收(UV_(254))、供电子能力(EDC)的相对剩余量与微污染有机物和亚硝胺消毒副产物的去除效能的关系。UV_(254)、EDC、微污染有机物、N-二甲基亚硝胺(NDMA)和总亚硝胺(TONO)生成势均随着臭氧投加量增大而逐渐降低,而且UV_(254)与EDC相对剩余量具有二阶线性相关性,因为UV_(254)和EDC都包含高活性芳香族化合物,二者降解均呈现良好相关性。UV_(254)、EDC相对剩余量与微污染有机物去除率具有良好的一阶或二阶线性关系,EDC相对剩余量与NDMA、TONO生成势具有良好的一阶或二阶线性关系。因此,使用EDC相对剩余量来同步指征臭氧氧化过程中微污染有机物和亚硝胺副消毒产物的去除效能,具有良好的应用前景。 展开更多
关键词 臭氧 EDC 微污染有机物 NDMA tono
下载PDF
软性角膜接触镜配戴对眼内压测量影响的研究 被引量:2
17
作者 徐玲娟 陈志祺 +2 位作者 向艳 李贵刚 张虹 《国际眼科杂志》 CAS 2011年第6期1058-1060,共3页
目的:观察配戴软性角膜接触镜对眼压测量的影响。方法:选取没有角膜病变的健康志愿者30例30眼(右眼)及无法以非接触眼压计测得眼压的患者21例21眼,角膜表面麻醉后,用非接触眼压计和Tono-pen眼压笔分别测量眼压,配戴角膜接触镜再次测量眼... 目的:观察配戴软性角膜接触镜对眼压测量的影响。方法:选取没有角膜病变的健康志愿者30例30眼(右眼)及无法以非接触眼压计测得眼压的患者21例21眼,角膜表面麻醉后,用非接触眼压计和Tono-pen眼压笔分别测量眼压,配戴角膜接触镜再次测量眼压,记录各次测得的平均眼压值。采用配对t检验比较配戴前后的眼压值及非接触眼压计与Tono-pen眼压笔所测得的眼压值的差异。结果:非接触式眼压计测量正常眼戴镜前后的眼压分别为:15.25±2.83mmHg和15.20±2.89mmHg(P=0.825);Tono-pen眼压笔测得戴镜前后的眼压值为15.93±2·43mmHg和16.60±3.09mmHg(P=0.146)。戴镜前后非接触眼压计与Tono-pen眼压笔所测得的眼压值没有统计学差异(P=0.052,0.096)。在21只无法以非接触眼压计测得眼压的患眼中,15眼戴镜后可测得眼压值,且所测得的眼压值与戴镜后Tono-pen所测得的眼压值没有明显差异(P=0·136)。患眼戴角膜接触镜前后Tono-pen眼压笔所测得的眼压值也没有明显的差异(P=0.266)。结论:配戴-0.50D软性角膜接触镜对正常眼及角膜病变眼眼压测量没有显著影响,提示有望以角膜接触镜作为媒介或载体实现眼压的测量和监控。 展开更多
关键词 角膜接触镜 眼压 非接触式眼压计 tono-pen眼 压笔
下载PDF
不同麻醉方式对大鼠高眼压模型眼压值的影响 被引量:4
18
作者 庞国龙 孙河 《中国中医眼科杂志》 2017年第1期8-10,共3页
目的为测量大鼠高眼压模型的眼压选择理想的麻醉方式。方法将构建成功后的高眼压模型大鼠30只,运用随机数字法随机分为水合氯醛组10只,七氟烷组10只,倍诺喜组10只;各组均给与相应组的麻醉药物进行麻醉后,分别在第8、11、14、17、20、24... 目的为测量大鼠高眼压模型的眼压选择理想的麻醉方式。方法将构建成功后的高眼压模型大鼠30只,运用随机数字法随机分为水合氯醛组10只,七氟烷组10只,倍诺喜组10只;各组均给与相应组的麻醉药物进行麻醉后,分别在第8、11、14、17、20、24、27、30 d的上午10点用Tono-pen-avia眼压计进行眼压测量,每只大鼠测量5次,取平均值。结果水合氯醛组和七氟烷组的眼压值在相应的时间点,结果基本相似,而倍诺喜组眼压值在相应的时间点较其他两组眼压值偏高,即水合氯醛组与七氟烷组在七个眼压监测点眼压差异无统计学意义(P>0.05);倍诺喜组眼压同其他两组相比差异有统计学意义(P<0.05),因此认为倍诺喜组的眼压值高于实际眼压值,水合氯醛组与七氟烷组眼压值更接近真实眼压值。结论三种麻醉方式中,七氟烷麻醉简便易行,测量的眼压值可靠性高,可在测眼压时选用。 展开更多
关键词 麻醉方式 眼压 高眼压模型 tono-pen-avia眼压计
下载PDF
4种不同眼压计测量值的比较 被引量:1
19
作者 李军 郭素平 《沈阳医学院学报》 2017年第2期100-102,105,共4页
目的:比较分析非接触式眼压计(NCT)、Icare回弹式眼压计(RBT)、Tono-pen眼压计(TPT)和Goldmann眼压计(GAT)的眼压测量结果,评价不同眼压计在临床的应用价值。方法:收集我院临床患者36例(72眼)分别用NCT、RBT、TPT和GAT眼压计测量眼压,... 目的:比较分析非接触式眼压计(NCT)、Icare回弹式眼压计(RBT)、Tono-pen眼压计(TPT)和Goldmann眼压计(GAT)的眼压测量结果,评价不同眼压计在临床的应用价值。方法:收集我院临床患者36例(72眼)分别用NCT、RBT、TPT和GAT眼压计测量眼压,然后根据GAT测得的眼压值分为3组,A组(眼压≤21 mmHg)、B组(21 mmHg<眼压≤30 mmHg)、C组(眼压>30 mmHg),对比分析不同眼压程度分组下各种眼压计的测量结果。结果:NCT-GAT平均差值在A组为(0.22±0.43)mm Hg(t=1.936,P=0.075),B组为(0.90±1.26)mm Hg(t=2.156,P=0.063),C组为(7.94±3.02)mm Hg(t=6.958,P=0.000);RBT-GAT平均差值在A组为(0.55±0.57)mm Hg(t=3.656,P=0.003),B组为(0.05±0.45)mm Hg(t=0.347,P=0.738),C组为(-0.53±1.71)mm Hg(t=-0.825,P=0.441);TPT-GAT平均差值在A组为(-0.66±0.99)mm Hg(t=-2.531,P=0.026),B组为(-0.50±0.62)mm Hg(t=-2.434,P=0.041),C组为(-2.25±2.67)mm Hg(t=-2.223,P=0.068)。结论:NCT、RBT均适用于在临床工作中青光眼的诊断,因眼压≤21 mmHg时,RBT测量的眼压值与GAT相比差异有统计学意义,故最好不用于青光眼随访,TPT仅适用于青光眼筛查。 展开更多
关键词 眼压 非接触式眼压计 ICARE回弹式眼压计 tono-PEN眼压计 GOLDMANN眼压计
下载PDF
LASIK前后两种眼压计测量结果的对比研究
20
作者 王海彬 郭海燕 +3 位作者 董志军 石晶 董微丽 张铁民 《承德医学院学报》 2011年第1期19-21,共3页
目的:探讨准分子激光原位角膜磨镶术(LASIK)后测量眼压的最佳方法。方法:45例(90只眼)近视眼患者分别于LASIK术前和术后6个月采用超声角膜厚度测量仪测量中央角膜厚度(CCT)和颞下角膜缘内1.5mm处周边角膜厚度(PCT),非接触眼压计(NCT)和T... 目的:探讨准分子激光原位角膜磨镶术(LASIK)后测量眼压的最佳方法。方法:45例(90只眼)近视眼患者分别于LASIK术前和术后6个月采用超声角膜厚度测量仪测量中央角膜厚度(CCT)和颞下角膜缘内1.5mm处周边角膜厚度(PCT),非接触眼压计(NCT)和Tono-Pen眼压计(TPT)测量角膜中央眼压、颞下角膜缘内1.5mm处周边眼压,并对眼压测量值和角膜厚度进行直线相关和回归分析。结果:LASIK术前、术后NCT眼压和CCT比较差异有统计学意义,术后明显低于术前(P<0.05);LASIK术前、术后TPT中央眼压、周边眼压以及PCT比较差异无显著性(P>0.05)。直线相关与回归分析结果表明,NCT眼压与CCT呈正相关(P<0.05);TPT中央眼压与CCT、NCT周边眼压与PCT均无相关性(P>0.05)。结论:TPT眼压受角膜厚度变化影响较小,可作为LASIK术后测量眼压的首选方法。 展开更多
关键词 近视 准分子激光原位角膜磨镶术 角膜厚度 非接触眼压计 tono-PEN眼压计
下载PDF