AIM:To analyze the correlation of Goldmann applanation tonometer(GAT),I-Care tonometer and Tono-Pen tonometer results in young healthy persons,and to investigate the influence of central corneal thickness(CCT)on ...AIM:To analyze the correlation of Goldmann applanation tonometer(GAT),I-Care tonometer and Tono-Pen tonometer results in young healthy persons,and to investigate the influence of central corneal thickness(CCT)on intraocular pressure(IOP)measurements recorded with these tonometers.·M ETHODS:We conducted a pilot clinical study in 78eyes of 78 subjects aged 22-28 years old(44 women and34 men;mean age 23.8±1.19y).IOP was measured using GAT,I-Care and Tono-Pen tonometers,followed by measurements of CCT.Statistical analysis was performed using SPSS 20.0.·RESULTS:The mean IOPs and standard deviation(±SD)for GAT,I-Care and Tono-Pen were 15.62±2.281 mm Hg,16.29±2.726 mm Hg and 16.32±2.393 mm Hg,respectively.The mean CCT was 555.15±29.648μm.Clear positive correlations between GAT and I-Care,GAT and TonoPen,and I-Care and Tono-Pen tonometers were found(=0.867,〈0.001;=0.861,〈0.001;=0.915,〈0.001,respectively).In comparison between devices,BlandAltman analysis showed a significant mean difference(MD)in the measurements by GAT and I-Care of-0.679 mm Hg and by GAT and Tono-Pen of-0.705 mm Hg(〈0.001),but there was no significant difference between I-Care and Tono-Pe(〉0.05).Both non-gold standard tonometers were affected by CCT;that is,both I-Care and Tono-Pen tonometer values were significantly higher with higher CCT means(〉555μm;MD=-1.282,〈0.001;MD=-0.949,〈0.001,respectively)compared with GAT.·CONCLUSION:Both I-Care and Tono-Pen tonometers overestimated IOP compared with the GAT values.Either the I-Care or Tono-Pen tonometer could be used instead of GAT because there was no significant difference between their results.Higher CCT values(〉555μm)were associated with overestimated IOP values.展开更多
Water and sediment samples were taken from selected irrigation dams located at Tono and Vea in the Upper East Region of Ghana and analyzed for organic pesticides using gas chromatography. Sixteen organic residues were...Water and sediment samples were taken from selected irrigation dams located at Tono and Vea in the Upper East Region of Ghana and analyzed for organic pesticides using gas chromatography. Sixteen organic residues were identified of which thirteen had at least some trace concentrations ranging from 0.001 to 25.4 μg/L. It was found in the laboratory that the concentrations of DDT, BHC and heptachlor were above the upper limited recommended by WHO and the concentrations of DDT in both reservoirs were higher than 20 times the recommended limits. High concentrations of DDT were found in the water samples while the other two residues were identified in the sediments. The high DDT concentration in water was due to 1) the initial amount of DDT applied and the period in the reservoirs, 2) a half-life of 350 days suggested that much of the DDT originally used was not destroyed if applied less than this period, 3) its low solubility in water did not allow for dissolution and subsequent dispersal in water;4) the indiscriminate uses of DDT for fishing as confirmed by the local people The high DDT level suggested that the water is not safe for many aquatic organisms and even humans. Generally the levels of these organic residues suggested that the dams have been polluted due to human activities such as farming and the unorthodox method of fishing. Therefore, steps should be taken to reduce the levels of DDT concentrations to preserve the aquatic life in the dams.展开更多
AIM: Tono-pen measurement of intraocular pressure(IOP) under topical anaesthesia in full term normal newborns. ·METHODS: The IOP measurements were taken using Tono-pen XL tonometer under topical anaesthesia in 15...AIM: Tono-pen measurement of intraocular pressure(IOP) under topical anaesthesia in full term normal newborns. ·METHODS: The IOP measurements were taken using Tono-pen XL tonometer under topical anaesthesia in 150 newborns(300 eyes) within 24h after birth,over a period of three months,in a university hospital. Gender,gestation period,mode of delivery and birth weight of newborns were noted from medical records. ·RESULTS: There were 70 males and 80 females. All babies were Malays. The IOP measurements were taken between 12 and 24h after birth. The gestation period of babies ranged between 37 and 41 weeks; 118 babies were delivered by spontaneous vaginal delivery and 32 by caesarian section. The birth weight of babies ranged between 2.1 and 4.3kg. The mean IOP of 300 eyes was 15.99±2.79mmHg(range 8-22). There was no statistically significant difference of mean IOP and gender,laterality of eye,type of delivery,gestation age,or birth weight of newborns. ·CONCLUSION: The IOP in full term normal newborns was 16mmHg. Tono-Pen appears to be ideal instrument for taking IOP in newborns because of its small size and easy handling.展开更多
In order to explore the difference of intraocular pressure(IOP) at different points of cornea before and after laser in situ keratomileusis(LASIK),IOP was measured by Tono-Pen Tonometer at central cornea,pericentr...In order to explore the difference of intraocular pressure(IOP) at different points of cornea before and after laser in situ keratomileusis(LASIK),IOP was measured by Tono-Pen Tonometer at central cornea,pericentral cornea and limbus respectively and analyzed statistically.After LASIK,IOP was dropped significantly at central cornea and pericentral cornea(P〈0.05),while no statistically significant change occurred at limbus(P〉0.05).There was no statistically significant difference in IOP at different points before LASIK(F=0.110,P=0.896),but statistically significant difference was found after LASIK(F=7.375,P=0.001).It was suggested that reliable IOP after LASIK could be obtained from the limbus by Tono-Pen tonometer.展开更多
文摘AIM:To analyze the correlation of Goldmann applanation tonometer(GAT),I-Care tonometer and Tono-Pen tonometer results in young healthy persons,and to investigate the influence of central corneal thickness(CCT)on intraocular pressure(IOP)measurements recorded with these tonometers.·M ETHODS:We conducted a pilot clinical study in 78eyes of 78 subjects aged 22-28 years old(44 women and34 men;mean age 23.8±1.19y).IOP was measured using GAT,I-Care and Tono-Pen tonometers,followed by measurements of CCT.Statistical analysis was performed using SPSS 20.0.·RESULTS:The mean IOPs and standard deviation(±SD)for GAT,I-Care and Tono-Pen were 15.62±2.281 mm Hg,16.29±2.726 mm Hg and 16.32±2.393 mm Hg,respectively.The mean CCT was 555.15±29.648μm.Clear positive correlations between GAT and I-Care,GAT and TonoPen,and I-Care and Tono-Pen tonometers were found(=0.867,〈0.001;=0.861,〈0.001;=0.915,〈0.001,respectively).In comparison between devices,BlandAltman analysis showed a significant mean difference(MD)in the measurements by GAT and I-Care of-0.679 mm Hg and by GAT and Tono-Pen of-0.705 mm Hg(〈0.001),but there was no significant difference between I-Care and Tono-Pe(〉0.05).Both non-gold standard tonometers were affected by CCT;that is,both I-Care and Tono-Pen tonometer values were significantly higher with higher CCT means(〉555μm;MD=-1.282,〈0.001;MD=-0.949,〈0.001,respectively)compared with GAT.·CONCLUSION:Both I-Care and Tono-Pen tonometers overestimated IOP compared with the GAT values.Either the I-Care or Tono-Pen tonometer could be used instead of GAT because there was no significant difference between their results.Higher CCT values(〉555μm)were associated with overestimated IOP values.
文摘Water and sediment samples were taken from selected irrigation dams located at Tono and Vea in the Upper East Region of Ghana and analyzed for organic pesticides using gas chromatography. Sixteen organic residues were identified of which thirteen had at least some trace concentrations ranging from 0.001 to 25.4 μg/L. It was found in the laboratory that the concentrations of DDT, BHC and heptachlor were above the upper limited recommended by WHO and the concentrations of DDT in both reservoirs were higher than 20 times the recommended limits. High concentrations of DDT were found in the water samples while the other two residues were identified in the sediments. The high DDT concentration in water was due to 1) the initial amount of DDT applied and the period in the reservoirs, 2) a half-life of 350 days suggested that much of the DDT originally used was not destroyed if applied less than this period, 3) its low solubility in water did not allow for dissolution and subsequent dispersal in water;4) the indiscriminate uses of DDT for fishing as confirmed by the local people The high DDT level suggested that the water is not safe for many aquatic organisms and even humans. Generally the levels of these organic residues suggested that the dams have been polluted due to human activities such as farming and the unorthodox method of fishing. Therefore, steps should be taken to reduce the levels of DDT concentrations to preserve the aquatic life in the dams.
文摘AIM: Tono-pen measurement of intraocular pressure(IOP) under topical anaesthesia in full term normal newborns. ·METHODS: The IOP measurements were taken using Tono-pen XL tonometer under topical anaesthesia in 150 newborns(300 eyes) within 24h after birth,over a period of three months,in a university hospital. Gender,gestation period,mode of delivery and birth weight of newborns were noted from medical records. ·RESULTS: There were 70 males and 80 females. All babies were Malays. The IOP measurements were taken between 12 and 24h after birth. The gestation period of babies ranged between 37 and 41 weeks; 118 babies were delivered by spontaneous vaginal delivery and 32 by caesarian section. The birth weight of babies ranged between 2.1 and 4.3kg. The mean IOP of 300 eyes was 15.99±2.79mmHg(range 8-22). There was no statistically significant difference of mean IOP and gender,laterality of eye,type of delivery,gestation age,or birth weight of newborns. ·CONCLUSION: The IOP in full term normal newborns was 16mmHg. Tono-Pen appears to be ideal instrument for taking IOP in newborns because of its small size and easy handling.
基金supported by the grants from the Science Foundation of Hubei Province,China (No. 2008CDB214,No. 2010CDB09802)
文摘In order to explore the difference of intraocular pressure(IOP) at different points of cornea before and after laser in situ keratomileusis(LASIK),IOP was measured by Tono-Pen Tonometer at central cornea,pericentral cornea and limbus respectively and analyzed statistically.After LASIK,IOP was dropped significantly at central cornea and pericentral cornea(P〈0.05),while no statistically significant change occurred at limbus(P〉0.05).There was no statistically significant difference in IOP at different points before LASIK(F=0.110,P=0.896),but statistically significant difference was found after LASIK(F=7.375,P=0.001).It was suggested that reliable IOP after LASIK could be obtained from the limbus by Tono-Pen tonometer.