期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
An iteration method for correcting the located coordinates of an underwater target
1
作者 WU Deming(Department of Radioelectronics, Peking University, Beijing 100871) 《Chinese Journal of Acoustics》 1992年第1期55-61,共7页
An iteration method for correcting the target coordinates determined by a locating system with a Cartesian array is reported. Under the complex hydrological condition, the method can give the target position not only ... An iteration method for correcting the target coordinates determined by a locating system with a Cartesian array is reported. Under the complex hydrological condition, the method can give the target position not only accurately but also quickly. The preliminary experimental results show that the correction is effective. An application of the method has been completed. 展开更多
关键词 An iteration method for correcting the located coordinates of an underwater target
原文传递
An optical sensor for hydrogen sulfide detection in open path using WMS-2f/1f technique 被引量:1
2
作者 宋丽梅 刘力文 +2 位作者 杨燕罡 郭庆华 习江涛 《Optoelectronics Letters》 EI 2016年第6期465-468,共4页
An optical hydrogen sulfide(H_2S) sensor based on wavelength modulation spectroscopy with the second harmonic(2f) corrected by the first harmonic(1f) signal(WMS-2f/1f) is developed using a distributed feedback(DFB) la... An optical hydrogen sulfide(H_2S) sensor based on wavelength modulation spectroscopy with the second harmonic(2f) corrected by the first harmonic(1f) signal(WMS-2f/1f) is developed using a distributed feedback(DFB) laser emitting at 1.578 μm and a homemade gas cell with 1-m-long optical path length. The novel sensor is constructed by an electrical cabinet and an optical reflecting and receiving end. The DFB laser is employed for targeting a strong H_2S line at 6 336.62 cm^(-1) in the fundamental absorption band of H_2S. The sensor performance, including the minimum detection limit and the stability, can be improved by reducing the laser intensity drift and common mode noise by means of the WMS-2f/1f technique. The experimental results indicate that the linearity and response time of the sensor are 0.999 26 and 6 s(in concentration range of 15.2—45.6 mg/m^3), respectively. The maximum relative deviation for continuous detection(60 min) of 30.4 mg/m^3 H_2S is 0.48% and the minimum detection limit obtained by Allan variance is 79 μg/m^3 with optimal integration time of 32 s. The optical H_2S sensor can be applied to environmental monitoring and industrial production, and it has significance for real-time online detection in many fields. 展开更多
关键词 corrected sulfide deviation Allan reflecting harmonic targeting drift linearity length
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部