期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Tensile Structures of Cables Net, Guidelines to Design and Applications
1
作者 Fabio Rizzo 《Open Journal of Civil Engineering》 2016年第2期254-285,共32页
The structural engineering design of not conventional typologies imposes a complex path that begins evaluating procedures of a preliminary design and ends with complex procedures to validate the analysis response. Any... The structural engineering design of not conventional typologies imposes a complex path that begins evaluating procedures of a preliminary design and ends with complex procedures to validate the analysis response. Any guide lines to follow are often available. About complex shapes, in particular, any details are presented in the codes to evaluate wind action and so wind tunnel experiments are necessary to valuate this. The evaluation of wind tunnel data is a complex process that often needs new and specific subroutines programmed by researchers. The difficult increases when the objective is to study a not specific building but general aspects as for examples the dependence of a generic phenomenon by a geometric sample;in this case it is necessary to design and to program numerical subroutines before and then the wind tunnel experiments. Often, these subroutines are left detached and are non-generalizable process. Purpose of this paper is to describe a complete procedure to pre- and post-process wind tunnel data with the objective to design a not convectional structure as a tensile structure. In this particular case the research aim is a parametrization of the aerodynamic behavior of Hyperbolic Paraboloid roofs, shape used for cables net. The reason of the experiments is the absence in the international codes of the pressure coefficients for these geometries. The paper describes the numerical procedure evaluated to choose a sufficient representative geometric sample, the numerical procedure evaluated to design and to construct the wind tunnel models and FE models, the numerical procedure to evaluate and to use for FEM analyses of the wind tunnel data, the numerical procedure to calculate nonlinear structural analysis, and, finally some applications. All these numerical procedures use basic theory derived for example by the cable theory, the fluid mechanic, the nonlinear geometric analysis and other. However specific codes were necessary and were programmed to apply the theories on the specific case of study;the complete methodology followed is presented. The goal is to create a free open domain where the numerical procedures evaluated are merged, added, modified by researchers with the aim to obtain a common space of use for wind engineering of not conventional structure. 展开更多
关键词 tensile structure Numerical Procedure tensile structures Cables Net Preliminary Design tensile Mesh Generator Wind Tunnel Testing
下载PDF
Numerical and experimental research on annular crossed cable-truss structure under cable rupture 被引量:5
2
作者 Liu Renjie Li Xiongyan +2 位作者 Xue Suduo Marijke Mollaert Ye Jihong 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2017年第3期557-569,共13页
The Annular Crossed Cable-Truss Structure(ACCTS) is a new type of Tensile Spatial Structure with a configuration suitable to cover large-span stadiums. Its configuration has potential to perform well in resisting di... The Annular Crossed Cable-Truss Structure(ACCTS) is a new type of Tensile Spatial Structure with a configuration suitable to cover large-span stadiums. Its configuration has potential to perform well in resisting disproportionate collapse. However, its disproportionate collapse resistance hasn't yet been analyzed in depth. In this study, numerical and experimental research was carried out to investigate the performance of ACCTS under cable rupture. The numerical analysis was done for ten cable-rupture plans using LS-DYNA(explicit method) and the experimental test on an ACCTS with a diameter of 17.15 m was performed for three cable-rupture plans. It is concluded that, while deflections increase with the number of removed cables, an ACCTS does not undergo a disproportionate collapse and it provides a promising structural concept for tensile spatial structures. 展开更多
关键词 tensile spatial structure annular tensile cable-truss structure disproportionate collapse
下载PDF
TEMPERING RESPONSE OF A DEFORMED LOW CARBON DUAL PHASE STRUCTURE
3
作者 JIN Man JIANG Zhonghao +2 位作者 NAN Shenghui HU Jiandong LIAN jianshe(Jilin University of Technology,Changchun,China)(Manuscript received 8 February 1995)Correspondent:LI Geping,(Institute of Metal Research,Chinese Academy of Sciences,Shenyang 110015,China) 《Acta Metallurgica Sinica(English Letters)》 SCIE EI CAS CSCD 1995年第2期79-83,共5页
The low carbon dual phase structure was cold de formed first,then was tempered at 200 to 600℃.The variation in strength and ductility during tempering of the steel was investigated.It was found that a fter the de for... The low carbon dual phase structure was cold de formed first,then was tempered at 200 to 600℃.The variation in strength and ductility during tempering of the steel was investigated.It was found that a fter the de formed dual phase structure was tempered at 200 to 600℃, with the increase in the tempering temperature the tensile strength decreases rapidly;the lotal elongation remains constant at 200 to 500℃ but began to rise dramatically at a critical temperature between 500 and 600℃.However,when the non-deformed dual phase structure was tempered at the same temperature range,the tensile strength decreases and the total elongation increases continuously with the increase of temperature.It was demonstrated from TEM analysis that precipitating carbides density along the boundaries ofmartensite lath and the recrystallized grains are responsible for the tempering response ofthe de formed dual phase structure. 展开更多
关键词 de formed dual phase structure tensile property tempering
下载PDF
Characteristics of structural loess strength and preliminary framework for joint strength formula 被引量:18
4
作者 Rong-jian LI Jun-ding LIU +2 位作者 Rui YAN Wen ZHENG Sheng-jun SHAO 《Water Science and Engineering》 EI CAS CSCD 2014年第3期319-330,共12页
The strength of structural loess consists of the shear strength and tensile strength. In this study, the stress path, the failure envelope of principal stress ( Kf line), and the strength failure envelope of structu... The strength of structural loess consists of the shear strength and tensile strength. In this study, the stress path, the failure envelope of principal stress ( Kf line), and the strength failure envelope of structurally intact loess and remolded loess were analyzed through three kinds of tests: the tensile strength test, the uniaxial compressive strength test, and the conventional triaxial shear strength test. Then, in order to describe the tensile strength and shear strength of structural loess comprehensively and reasonably, a joint strength formula for structural loess was established. This formula comprehensively considers tensile and shear properties. Studies have shown that the tensile strength exhibits a decreasing trend with increasing water content. When the water content is constant, the tensile strength of the structurally intact soil is greater than that ofremolded soil. In the studies, no loss of the originally cured cohesion in the structurally intact soil samples was observed, given that the soil samples did not experience loading disturbance during the uniaxial compressive strength test, meaning there is a high initial structural strength. The results of the conventional triaxial shear strength test show that the water content is correlated with the strength of the structural loess. When the water content is low, the structural properties are strong, and when the water content is high, the structural properties are weak, which means that the water content and the ambient pressure have significant effects on the stress-strain relationship of structural loess. The established joint strength formula of structural loess effectively avoids overestimating the role of soil tensile strength in the traditional theory of Mohr-Coulomb strength. 展开更多
关键词 structurally intact loess remolded loess tensile strength shear strength stress path failure envelope of principal stress Kf line) strength failure envelope joint strength formula
下载PDF
Anodic Oxidation on Structural Evolution and Tensile Properties of Polyacrylonitrile Based Carbon Fibers with Different Surface Morphology 被引量:3
5
作者 Zhaorui Li Jianbin Wang Yuanjian Tong Lianghua Xu 《Journal of Materials Science & Technology》 SCIE EI CAS CSCD 2012年第12期1123-1129,共7页
Polyacrylonitrile (PAN) based carbon fibers with different surface morphology were electrochemically treated in 3 wt% NH4HCO3 aqueous solution with current density up to 3.47 A/m 2 at room temperature, and surface s... Polyacrylonitrile (PAN) based carbon fibers with different surface morphology were electrochemically treated in 3 wt% NH4HCO3 aqueous solution with current density up to 3.47 A/m 2 at room temperature, and surface structures, surface morphology and residual mechanical properties were characterized. The crystallite size (La) of carbon fibers would be interrupted due to excessive electrochemical etching, while the crystallite spacing (d(002)) increased as increasing current density. The disordered structures on the surface of carbon fiber with rough surface increased at the initial oxidation stage and then removed by further electrochemical etching, which resulting in continuous increase of the extent of graphitization on the fiber surface. However, the electrochemical etching was beneficial to getting ordered morphology on the surface for carbon fiber with smooth surface, especially when the current density was lower than 1.77 A/m 2 . The tensile strength and tensile modulus could be improved by 17.27% and 5.75%, respectively, and was dependent of surface morphology. The decreasing density of carbon fibers probably resulted from the volume expansion of carbon fibers caused by the abundant oxygen functional groups intercalated between the adjacent graphite layers. 展开更多
关键词 Carbon fibers Anodic oxidation Structural evolution tensile property Surface morphology
原文传递
Evaluation of tensile properties of a compositemetal joint with a novel metal insert design by experimental and numerical methods 被引量:2
6
作者 Xiaoquan CHENG Xiaoqi LI +3 位作者 Jie ZHANG Qian ZHANG Yujia CHENG Benyin ZENG 《Chinese Journal of Aeronautics》 SCIE EI CAS CSCD 2017年第3期1004-1011,共8页
Composite-metal joints with a metal insert are one kind of connecting structure.In this paper,tensile experimental tests were carried out to investigate tensile properties of a compositemetal joint with a novel metal ... Composite-metal joints with a metal insert are one kind of connecting structure.In this paper,tensile experimental tests were carried out to investigate tensile properties of a compositemetal joint with a novel metal insert design.Finite element models of the joint were established,and strain distribution and tensile strength were analyzed.The numerical results are in good agreement with the experimental results.Results show that the joint failure is dominated by shear properties of the resin layer.Increasing the resin layer thickness in a certain range will improve the tensile strength of the joint,while increasing the radius of the fillet on the ending side of the metal insert will decrease the joint strength.Increasing the resin layer plasticity will improve the joint strength.The effect of the embedded depth of the metal insert can be ignored. 展开更多
关键词 Composite structure Failure mode Joints Metal insert tensile properties
原文传递
Data-driven placemaking: Public space canopy design through multi-objective optimisation considering shading, structural and social performance
7
作者 Jeroen van Ameijde Chun Yu Ma +2 位作者 Garvin Goepel Clive Kirsten Jeff Wong 《Frontiers of Architectural Research》 CSCD 2022年第2期308-323,共16页
In the context of ongoing densification of cities and aging urban populations,public spaces are a crucial infrastructure to support the physical and mental wellbeing of urban residents.The design of public space furni... In the context of ongoing densification of cities and aging urban populations,public spaces are a crucial infrastructure to support the physical and mental wellbeing of urban residents.The design of public space furniture elements is often standardised,and not considered in relation to environmental conditions and mechanisms of social interaction.This article presents a digital workflow to generate site-specific designs for shaded public seating,considering the relationships of local public places to their surroundings.A strategy for customised and site-specific design is developed through the use of multiple software tools,employing evolutionary algorithms and multi-objective optimisation.The method is applied to a small public space canopy prototype installed within a public housing estate in Hong Kong,incorporating additional criteria to achieve a low-cost and light-weight structure.Through multiple stages of refinement and optimisation,a material,structural and social performance-driven outcome was achieved that creates a shaded space for public seating,people watching and social interaction.As part of a larger research agenda exploring architectural form-finding and environmental psychology,the project represents potential new applications in the emerging field of socially driven computational design. 展开更多
关键词 Public space tensile membrane structures Structural design Environmental performance Multi-objective optimisation Evolutionary algorithms
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部