期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Terahertz Three-Dimensional Imaging Based on Computed Tomography with Photonics-Based Noise Source 被引量:3
1
作者 周涛 张戎 +3 位作者 姚辰 符张龙 邵棣祥 曹俊诚 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第8期76-78,共3页
Computed tomography has been proven to be useful for non-destructive inspection of structures and materials. We build a three-dimensional imaging system with the photonically generated incoherent noise source and the ... Computed tomography has been proven to be useful for non-destructive inspection of structures and materials. We build a three-dimensional imaging system with the photonically generated incoherent noise source and the Schottky barrier diode detector in the terahertz frequency band (90–140GHz). Based on the computed tomography technique, the three-dimensional image of a ceramic sample is reconstructed successfully by stacking the slices at different heights. The imaging results not only indicate the ability of terahertz wave in the non-invasive sensing and non-destructive inspection applications, but also prove the effectiveness and superiority of the uni-traveling-carrier photodiode as a terahertz source in the imaging applications. 展开更多
关键词 THz terahertz Three-Dimensional Imaging Based on Computed tomography with Photonics-Based Noise Source
下载PDF
Mural Defects Detection with Enhanced Terahertz Images
2
作者 Min-Jie Yuan Wen-Feng Sun +4 位作者 Xin-Ke Wang Jia-Sheng Ye Sen Wang Qun-Xi Zhang Yan Zhang 《Journal of Electronic Science and Technology》 CAS CSCD 2016年第4期337-342,共6页
In mausoleum murals, existing bubbles are one kind of the most harmful defects for the repair and protection of relics. For this reason, it is necessary to detect bubbles, especially the ones with small size. A method... In mausoleum murals, existing bubbles are one kind of the most harmful defects for the repair and protection of relics. For this reason, it is necessary to detect bubbles, especially the ones with small size. A method to detect the small bubbles with enhanced terahertz (THz) images is proposed. To simulate the bubbles in the mausoleum murals, circular grooves have been hidden in the plaster and then measured by the THz reflected time domain spectroscopy imaging system. To observe the small bubbles in murals, a comprehensive enhancement algorithm is adopted to process the obtained THz images. With the enhanced method, the circular grooves in the murals can be observed clearly, even for the circular groove with a diameter of 1.5 mm. The results indicate that the proposed comprehensive method can be used to detect the tiny defects of murals. 展开更多
关键词 Comprehensive enhancement algorithm MURALS non-invasive detection terahertz tomography.
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部