By using the meteorological data in the pollution boundary layer which was observed in two ground observation sites:coast and land in the river outlet area of Grand Liao River during January-February in 2007,the daily...By using the meteorological data in the pollution boundary layer which was observed in two ground observation sites:coast and land in the river outlet area of Grand Liao River during January-February in 2007,the daily change characteristics of pollute boundary layer in winter in the area were discussed. The results showed that the pollute boundary layer in the river outlet area of Grand Liao River was affected by the sea and land. In the certain weather condition,maybe the sea-land breeze appeared in the low altitude which was below 200 m in the coastal zone. The stability change in the different height in the coastal zone was more stable than in the land zone,and the wind field change in the area was mainly in 300 m low altitude. At night,the temperature inversion often appears in the area,and the thickness of temperature inversion layer is stably during 200-300 m. The thermal internal boundary layer penetrated deeply into the land about 10 km,and the height could reach 800 m. The atmospheric diffusion ability in the coastal area was weaker and stronger in the land area.展开更多
The 37th Language Testing Research Colloquium(LTRC 2015①)was held at Eaton Chelsea Hotel in Toronto Canada during March 16-20,2015.The first two days of March 16-17 were preconference workshop days with March 18-20 a...The 37th Language Testing Research Colloquium(LTRC 2015①)was held at Eaton Chelsea Hotel in Toronto Canada during March 16-20,2015.The first two days of March 16-17 were preconference workshop days with March 18-20 as the three main conference days.More than 300 participants from 27 countries and regions joined the conference.The top numbers of the展开更多
750 kV substation of Riyue Mountain, Qinghai is a substation that annual average thunderstorm days are the maximum at the same volt- age level and altitude in the wodd. We detailedly described testing methods and step...750 kV substation of Riyue Mountain, Qinghai is a substation that annual average thunderstorm days are the maximum at the same volt- age level and altitude in the wodd. We detailedly described testing methods and steps of 6 characteristic parameters for grounding device of 750 kV substation by using 8000S comprehensive test system, and scientifically judged overall performance of the grounding device. Moreover, we espe- cially emphasized key and difficult points in testing process, providing reference for the majority of grounding test workers.展开更多
A unit pump test bench is developed on an in-line pump test platform. The bench is composed of pump adapting assembly, fuel supply subsystem, lubricating subsystem and a control unit. A crank angle domain injection co...A unit pump test bench is developed on an in-line pump test platform. The bench is composed of pump adapting assembly, fuel supply subsystem, lubricating subsystem and a control unit. A crank angle domain injection control method is given out and the control accuracy can be 0.1° crank degree. The bench can test both mechanical unit pump and electronic unit pump. A test model-PLD12 electronic unit pump is tested. Full pump delivery map and some influence factors test is done. Experimental results show that the injection quantity is linear with the delivery angle. The quantity change rate is 15% when fuel temperature increases 30 ℃. The delivery quantity per cycle increases 30 mg at 28 V drive voltage. The average delivery difference for two same type pumps is 5 %. Test results show that the bench can be used for unit pump verification.展开更多
The sonic fatigue life of the aluminium rectangular panel was calculated using the concise method[1], and the sonic fatigue test was conducted on progressive wave tube (PWT) test facility. A comparison was made betwee...The sonic fatigue life of the aluminium rectangular panel was calculated using the concise method[1], and the sonic fatigue test was conducted on progressive wave tube (PWT) test facility. A comparison was made between the results of calculation and test, and it shows reasonable agreement between these two results.展开更多
As many chemicals with genotoxic potential are emitted to surface water, genotoxicity tests are gaining importance which led to the development of several techniques to detect directly DNA damage. The relevance of det...As many chemicals with genotoxic potential are emitted to surface water, genotoxicity tests are gaining importance which led to the development of several techniques to detect directly DNA damage. The relevance of detecting the genotoxic risks associated with water pollution was firstly perceived in the late 1970s. Since that time several tests have been developed for evaluating DNA alterations in aquatic animals. These tests rely on the premise that any changes to DNA may have long-lasting and profound consequences. Sister chromatid test, chromosome aberrations, comet assay, and micronucleus test are currently the most widely employed methods to detect DNA lesions in ecotoxicology. Chromosomal aberration and sister chromatid exchanges are time consuming, resource intensive and require proliferating cell population. Hence, Comet assay and Micronucleus test as cost effective and more sensitive test systems have now been introduced for assessing the genotoxicity of chemicals. This review presents a synthesis of the state of the art in the methodologies of comet assay and micronucleus test and their contributions in aquatic environmental research. The text explores the latest knowledge and thinking on these very important approaches for the assessment of environmental health, management, and conservation. The primary concern of the present review is the measurement of genotoxic potential in aquatic organisms under field and laboratory conditions, where effects of chemicals at different levels of biological organization can be examined.展开更多
基金Supported by The Special Project of Public Welfare Industry(Meteorology)of Science and Technology Ministry(GYHY200806020)The National Natural Science Fund(40975084)The Science Research Fund of Liaoning Meteorological Bureau(2008008)
文摘By using the meteorological data in the pollution boundary layer which was observed in two ground observation sites:coast and land in the river outlet area of Grand Liao River during January-February in 2007,the daily change characteristics of pollute boundary layer in winter in the area were discussed. The results showed that the pollute boundary layer in the river outlet area of Grand Liao River was affected by the sea and land. In the certain weather condition,maybe the sea-land breeze appeared in the low altitude which was below 200 m in the coastal zone. The stability change in the different height in the coastal zone was more stable than in the land zone,and the wind field change in the area was mainly in 300 m low altitude. At night,the temperature inversion often appears in the area,and the thickness of temperature inversion layer is stably during 200-300 m. The thermal internal boundary layer penetrated deeply into the land about 10 km,and the height could reach 800 m. The atmospheric diffusion ability in the coastal area was weaker and stronger in the land area.
文摘The 37th Language Testing Research Colloquium(LTRC 2015①)was held at Eaton Chelsea Hotel in Toronto Canada during March 16-20,2015.The first two days of March 16-17 were preconference workshop days with March 18-20 as the three main conference days.More than 300 participants from 27 countries and regions joined the conference.The top numbers of the
文摘750 kV substation of Riyue Mountain, Qinghai is a substation that annual average thunderstorm days are the maximum at the same volt- age level and altitude in the wodd. We detailedly described testing methods and steps of 6 characteristic parameters for grounding device of 750 kV substation by using 8000S comprehensive test system, and scientifically judged overall performance of the grounding device. Moreover, we espe- cially emphasized key and difficult points in testing process, providing reference for the majority of grounding test workers.
基金the Ministerial Level Advanced Research Foundation (404050301 .4)
文摘A unit pump test bench is developed on an in-line pump test platform. The bench is composed of pump adapting assembly, fuel supply subsystem, lubricating subsystem and a control unit. A crank angle domain injection control method is given out and the control accuracy can be 0.1° crank degree. The bench can test both mechanical unit pump and electronic unit pump. A test model-PLD12 electronic unit pump is tested. Full pump delivery map and some influence factors test is done. Experimental results show that the injection quantity is linear with the delivery angle. The quantity change rate is 15% when fuel temperature increases 30 ℃. The delivery quantity per cycle increases 30 mg at 28 V drive voltage. The average delivery difference for two same type pumps is 5 %. Test results show that the bench can be used for unit pump verification.
文摘The sonic fatigue life of the aluminium rectangular panel was calculated using the concise method[1], and the sonic fatigue test was conducted on progressive wave tube (PWT) test facility. A comparison was made between the results of calculation and test, and it shows reasonable agreement between these two results.
文摘As many chemicals with genotoxic potential are emitted to surface water, genotoxicity tests are gaining importance which led to the development of several techniques to detect directly DNA damage. The relevance of detecting the genotoxic risks associated with water pollution was firstly perceived in the late 1970s. Since that time several tests have been developed for evaluating DNA alterations in aquatic animals. These tests rely on the premise that any changes to DNA may have long-lasting and profound consequences. Sister chromatid test, chromosome aberrations, comet assay, and micronucleus test are currently the most widely employed methods to detect DNA lesions in ecotoxicology. Chromosomal aberration and sister chromatid exchanges are time consuming, resource intensive and require proliferating cell population. Hence, Comet assay and Micronucleus test as cost effective and more sensitive test systems have now been introduced for assessing the genotoxicity of chemicals. This review presents a synthesis of the state of the art in the methodologies of comet assay and micronucleus test and their contributions in aquatic environmental research. The text explores the latest knowledge and thinking on these very important approaches for the assessment of environmental health, management, and conservation. The primary concern of the present review is the measurement of genotoxic potential in aquatic organisms under field and laboratory conditions, where effects of chemicals at different levels of biological organization can be examined.