The deformation characteristic of bland in deep drawing is discussed. It is pointed out that the friction and lubrication conditions in for drawing are different from that in mechanical motion or machine work or other...The deformation characteristic of bland in deep drawing is discussed. It is pointed out that the friction and lubrication conditions in for drawing are different from that in mechanical motion or machine work or other plastic process. The common test methods in laboratories are analyzed. It shows that though all those test methods can test the friction coefficient, the probe test method is most suitable for the research of friction and lubrication and the process in deep drawing, for this method is identical with the actual work condition either from the test principle or deformation status of the blank. Last the successful application in the deep drawing simulator newly developed the the probe method are intro- duced in detail.展开更多
A probe test method was employed to detect the friction condition of the interfaces between tools and blank. At the same time a self-developed measurement apparatus to realize the probe test method was also presented....A probe test method was employed to detect the friction condition of the interfaces between tools and blank. At the same time a self-developed measurement apparatus to realize the probe test method was also presented. Based on the analysis of force, a correlative friction model was also given. With the self-developed measurement apparatus,the effects of three kinds of lubricating oils which were in common use during the process of sheet steel drawing were studied. By probing the friction coefficient values of different lubricating oils during the drawing process of the hot-galvanized sheet steel (steel brand: ST07Zn), we can see that the friction caused by PK oil was the lowest, so the effect of PK oil was the best. Then PK oil was used as the base lubricating oil and some solid additive powers was added into it to make a new type lubrication (named as L oil).The result of test proved that the new lubricating oil had remarkable effect on the drawing process of hot-galvanized sheet steel.展开更多
Galvanic corrosion on samples of AZ91D magnesium alloy coupled with 2A12 aluminum alloy during neutral salt spray test was investigated.The variations of the surface potential were measured using scanning kelvin probe...Galvanic corrosion on samples of AZ91D magnesium alloy coupled with 2A12 aluminum alloy during neutral salt spray test was investigated.The variations of the surface potential were measured using scanning kelvin probe(SKP).The results showed that galvanic effect on the corrosion of AZ91D magnesium alloy is closely related to the potential difference between the anodic and cathodic materials.In the initial period,corrosion only occurred in a narrow area at the coupling interface because of the limited distance galvanic current.Then,the corrosion rate of 2A12 aluminum alloy was accelerated due to its poor stability in strong alkali environment,which was attributed to the strong alkalization caused by the corrosion of AZ91D magnesium alloy.With the increase of the potential of 2A12 aluminum alloy as a result of the continuous covering of corrosion products,the potential difference between the two materials was enlarged,which enhanced the galvanic corrosion.展开更多
The corrosion behavior of partly coated carbon steel was investigated by salt spray test and scanning Kelvin probe (SKP) in order to understand the long-term corrosion behavior of coated carbon steel in marine atmos...The corrosion behavior of partly coated carbon steel was investigated by salt spray test and scanning Kelvin probe (SKP) in order to understand the long-term corrosion behavior of coated carbon steel in marine atmosphere environment. The localized corrosion was accurately characterized by SKP in both coated and uncoated regions. The SKP results showed that Volta potential varied with the test time, and the more the corrosion products, the more positive the potential. The borderline between coated and uncoated regions of partly coated steel shifted towards the coated side with the increasing of test time. The coating disbonding rate could be determined according to the shift of potential borderline measured by SKP. The corrosion mechanism of partly coated steel in NaCl salt spray was discussed according to the potential maps and corrosion morphologies.展开更多
A differential excitation probe based on eddy current testing technology was designed. Sheet specimens of Q 235 steel with prefabricated micro-cracks of different widths and of aluminum with prefabricated micro-cracks...A differential excitation probe based on eddy current testing technology was designed. Sheet specimens of Q 235 steel with prefabricated micro-cracks of different widths and of aluminum with prefabricated micro-cracks of different depths were detected through the designed detection system. The characteristics of micro-cracks can be clearly showed after signals processing through the short-time Fourier transform( STFT). By changing the parameter and its value in detecting process,the factors including the excitation frequency and amplitude,the lift-off effect and the scanning direction were discussed,respectively. The results showed that the differential excitation probe was insensitive to dimension and surface state of the tested specimen,while it had a high degree of recognition for micro-crack detection. Therefore,when the differential excitation detection technology was used for inspecting micro-crack of turbine blade in aero-engine,and smoothed pseudo Wigner-Ville distribution was used for signal processing,micro-cracks of 0. 3 mm depth and 0. 1 mm width could be identified. The experimental results might be useful for further research on engineering test of turbine blades of aero-engine.展开更多
This paper tested the viscosity of prepreg in the automatic placement process, and conducted the probe and placement-90° peel tests through the test systems. The law of variation of prepreg viscosity during the l...This paper tested the viscosity of prepreg in the automatic placement process, and conducted the probe and placement-90° peel tests through the test systems. The law of variation of prepreg viscosity during the laying process was studied through these tests under different conditions by taking the peel force to intuitively and quantitatively characterise the viscosity of the prepreg.The results show that this viscosity is inversely proportional to the laying rate, proportional to the laying pressure, and quadratic to the laying temperature. Then, peel tests were simulated to validate both the correctness of the peel test and that of the probe test data fitting the two-line cohesion model. On this basis, a response surface test for laying and peeling was designed. Taking viscous peel force as the response target, the laying process parameters were optimised and the significance of their influence was further studied. The error between the test value and the predicted value of the maximum viscous peel force is 3.03%.展开更多
Background:Nasal insertion is the preferred method for non-intubated patients in flexible bronchoscopy;however,the relatively narrow nasal cavity results in difficulties related to bronchoscope insertion.This study ai...Background:Nasal insertion is the preferred method for non-intubated patients in flexible bronchoscopy;however,the relatively narrow nasal cavity results in difficulties related to bronchoscope insertion.This study aimed to investigate whether pre-operative nasal probe tests could reduce the time to pass the glottis,improve the first-pass success rate and patients’tolerance,and reduce postoperative bleeding.Methods:This three-arm prospective randomized controlled trial was conducted in a tertiary hospital between May and October 2020.Three hundred patients requiring diagnosis and treatment using flexible bronchoscopy were randomly allocated to three groups:control group,simple cotton bud detection group(CD group),and adrenaline+lidocaine detection group(AD group).The primary outcome was the time to pass the glottis.Secondary outcomes included the first-pass success rate,the patients’tolerance scores,and post-operative bleeding.One-way analysis of variance,Kruskal-WallisH test,Chi-squared test,Fisher’s exact test,and Bonferroni’s multiple comparison tests were used in this study.Results:In total,189 men and 111 women were enrolled in this study,with a mean age of 55.72±12.86 years.The insertion time was significantly shorter in the AD group than in the control group(18.00 s[12.00–26.50 s]vs.24.00 s[14.50–45.50 s],P=0.005).Both the AD(99%vs.83%,χ2=15.62,P<0.001)and CD groups(94%vs.83%,χ2=5.94,P=0.015)had a significantly higher first-pass success rate than the control group.Compared with the control group,post-operative bleeding(1%vs.13%,χ2=11.06,P<0.001)was significantly lower in the AD group.However,no significant difference was found in the patients’tolerance scores.Conclusions:Pre-operative nasal cavity probe tests especially with adrenaline and lidocaine during flexible bronchoscopy can significantly reduce the time to pass the glottis,improve the first-pass success rate,and reduce post-operative nasal bleeding.Pre-operative nasal probe tests are recommended as a time-saving procedure for patients undergoing flexible bronchoscopy.Trial registration:Chinese Clinical Trial Registry(ChiCTR),ChiCTR2000032668;http://www.chictr.org.cn/showprojen.aspx?proj=53321.展开更多
文摘The deformation characteristic of bland in deep drawing is discussed. It is pointed out that the friction and lubrication conditions in for drawing are different from that in mechanical motion or machine work or other plastic process. The common test methods in laboratories are analyzed. It shows that though all those test methods can test the friction coefficient, the probe test method is most suitable for the research of friction and lubrication and the process in deep drawing, for this method is identical with the actual work condition either from the test principle or deformation status of the blank. Last the successful application in the deep drawing simulator newly developed the the probe method are intro- duced in detail.
文摘A probe test method was employed to detect the friction condition of the interfaces between tools and blank. At the same time a self-developed measurement apparatus to realize the probe test method was also presented. Based on the analysis of force, a correlative friction model was also given. With the self-developed measurement apparatus,the effects of three kinds of lubricating oils which were in common use during the process of sheet steel drawing were studied. By probing the friction coefficient values of different lubricating oils during the drawing process of the hot-galvanized sheet steel (steel brand: ST07Zn), we can see that the friction caused by PK oil was the lowest, so the effect of PK oil was the best. Then PK oil was used as the base lubricating oil and some solid additive powers was added into it to make a new type lubrication (named as L oil).The result of test proved that the new lubricating oil had remarkable effect on the drawing process of hot-galvanized sheet steel.
基金Funded by the National Natural Science Foundation of China(No.51271032)
文摘Galvanic corrosion on samples of AZ91D magnesium alloy coupled with 2A12 aluminum alloy during neutral salt spray test was investigated.The variations of the surface potential were measured using scanning kelvin probe(SKP).The results showed that galvanic effect on the corrosion of AZ91D magnesium alloy is closely related to the potential difference between the anodic and cathodic materials.In the initial period,corrosion only occurred in a narrow area at the coupling interface because of the limited distance galvanic current.Then,the corrosion rate of 2A12 aluminum alloy was accelerated due to its poor stability in strong alkali environment,which was attributed to the strong alkalization caused by the corrosion of AZ91D magnesium alloy.With the increase of the potential of 2A12 aluminum alloy as a result of the continuous covering of corrosion products,the potential difference between the two materials was enlarged,which enhanced the galvanic corrosion.
基金the National Natural Science Foundation of China (Nos.50871021and50701006)
文摘The corrosion behavior of partly coated carbon steel was investigated by salt spray test and scanning Kelvin probe (SKP) in order to understand the long-term corrosion behavior of coated carbon steel in marine atmosphere environment. The localized corrosion was accurately characterized by SKP in both coated and uncoated regions. The SKP results showed that Volta potential varied with the test time, and the more the corrosion products, the more positive the potential. The borderline between coated and uncoated regions of partly coated steel shifted towards the coated side with the increasing of test time. The coating disbonding rate could be determined according to the shift of potential borderline measured by SKP. The corrosion mechanism of partly coated steel in NaCl salt spray was discussed according to the potential maps and corrosion morphologies.
基金Supported by the Ministerial Level Advanced Research Foundation(051317030586)Ph.D.Programs Foundation of the Ministry of Education of China(20121101110018)
文摘A differential excitation probe based on eddy current testing technology was designed. Sheet specimens of Q 235 steel with prefabricated micro-cracks of different widths and of aluminum with prefabricated micro-cracks of different depths were detected through the designed detection system. The characteristics of micro-cracks can be clearly showed after signals processing through the short-time Fourier transform( STFT). By changing the parameter and its value in detecting process,the factors including the excitation frequency and amplitude,the lift-off effect and the scanning direction were discussed,respectively. The results showed that the differential excitation probe was insensitive to dimension and surface state of the tested specimen,while it had a high degree of recognition for micro-crack detection. Therefore,when the differential excitation detection technology was used for inspecting micro-crack of turbine blade in aero-engine,and smoothed pseudo Wigner-Ville distribution was used for signal processing,micro-cracks of 0. 3 mm depth and 0. 1 mm width could be identified. The experimental results might be useful for further research on engineering test of turbine blades of aero-engine.
基金supported by the National Natural Science Foundation of China(No.51875159)the Foshan Xianhu Laboratory of the Advanced Energy Science and Technology Guangdong Laboratory,China(No.XHT 2020-002)+5 种基金Fok Ying Tung Education Foundation,China(No.171046)the Key Research and Development Program of Anhui Province,China(No.201904d07020013)the Fundamental Research Funds for the Central Universities,China(Nos.PA2020GDJQ0029 and PA2020GDSK0075)the National Key Research and Development Project,China(No.2019YFB1504800)the Beijing Natural Science Foundation,China(No.2192044)2020 and 2021 Open Project of State Key Laboratory of Organic-Inorganic Composites,China(Nos.Oic-202001008 and Oic-202101008)。
文摘This paper tested the viscosity of prepreg in the automatic placement process, and conducted the probe and placement-90° peel tests through the test systems. The law of variation of prepreg viscosity during the laying process was studied through these tests under different conditions by taking the peel force to intuitively and quantitatively characterise the viscosity of the prepreg.The results show that this viscosity is inversely proportional to the laying rate, proportional to the laying pressure, and quadratic to the laying temperature. Then, peel tests were simulated to validate both the correctness of the peel test and that of the probe test data fitting the two-line cohesion model. On this basis, a response surface test for laying and peeling was designed. Taking viscous peel force as the response target, the laying process parameters were optimised and the significance of their influence was further studied. The error between the test value and the predicted value of the maximum viscous peel force is 3.03%.
基金National Natural Science Foundation of China(NSFC No.81770072)The"1.3.5 project for disciplines of excellence,West China Hospital,Sichuan University(No.ZYJC18021)Chengdu Science and Technology Bureau(No.2018-CY02-00064-GX)。
文摘Background:Nasal insertion is the preferred method for non-intubated patients in flexible bronchoscopy;however,the relatively narrow nasal cavity results in difficulties related to bronchoscope insertion.This study aimed to investigate whether pre-operative nasal probe tests could reduce the time to pass the glottis,improve the first-pass success rate and patients’tolerance,and reduce postoperative bleeding.Methods:This three-arm prospective randomized controlled trial was conducted in a tertiary hospital between May and October 2020.Three hundred patients requiring diagnosis and treatment using flexible bronchoscopy were randomly allocated to three groups:control group,simple cotton bud detection group(CD group),and adrenaline+lidocaine detection group(AD group).The primary outcome was the time to pass the glottis.Secondary outcomes included the first-pass success rate,the patients’tolerance scores,and post-operative bleeding.One-way analysis of variance,Kruskal-WallisH test,Chi-squared test,Fisher’s exact test,and Bonferroni’s multiple comparison tests were used in this study.Results:In total,189 men and 111 women were enrolled in this study,with a mean age of 55.72±12.86 years.The insertion time was significantly shorter in the AD group than in the control group(18.00 s[12.00–26.50 s]vs.24.00 s[14.50–45.50 s],P=0.005).Both the AD(99%vs.83%,χ2=15.62,P<0.001)and CD groups(94%vs.83%,χ2=5.94,P=0.015)had a significantly higher first-pass success rate than the control group.Compared with the control group,post-operative bleeding(1%vs.13%,χ2=11.06,P<0.001)was significantly lower in the AD group.However,no significant difference was found in the patients’tolerance scores.Conclusions:Pre-operative nasal cavity probe tests especially with adrenaline and lidocaine during flexible bronchoscopy can significantly reduce the time to pass the glottis,improve the first-pass success rate,and reduce post-operative nasal bleeding.Pre-operative nasal probe tests are recommended as a time-saving procedure for patients undergoing flexible bronchoscopy.Trial registration:Chinese Clinical Trial Registry(ChiCTR),ChiCTR2000032668;http://www.chictr.org.cn/showprojen.aspx?proj=53321.