Background:The aim of this study was to investigate the influence of marking meth-ods on the outcomes of body composition analysis and provide guidance for the se-lection of marking methods in mouse body composition a...Background:The aim of this study was to investigate the influence of marking meth-ods on the outcomes of body composition analysis and provide guidance for the se-lection of marking methods in mouse body composition analysis.Methods:Male C57BL/6J mice aged 6 weeks were randomly assigned for pre-and post-ear tagging measurements.The body composition of the mice was measured using a small animal body composition analyzer,which provided measurements of the mass of fat,lean,and free fluid.Then,the mass of fat,lean and free fluid to body weight ratio was gained.Further data analysis was conducted to obtain the range and coeffi-cient of variation in body composition measurements for each mouse.The distribution of fat and lean tissue in the mice was also analyzed by comparing the fat-to-lean ratio.Results:(1)The mass of all body composition components in the ear tagging group was significantly lower than that in the control group.(2)There was a significant in-crease in the range and coefficient of variation of body composition measurements between the ear tagging group and the control group.(3)The fat-to-lean ratio in the ear tagging group was significantly lower than that in the control group.Conclusions:Ear tagging significantly lowered the results of body composition analy-sis in mice and higher the results of measurement error.Therefore,ear tagging should be avoided as much as possible when conducting body composition analysis experi-ments in mice.展开更多
A backfilling body-coal pillar-backfilling body(BPB)structure formed by pillar-side cemented paste backfilling can bear overburden stress and ensure safe mining.However,the failure response of BPB composite samples mu...A backfilling body-coal pillar-backfilling body(BPB)structure formed by pillar-side cemented paste backfilling can bear overburden stress and ensure safe mining.However,the failure response of BPB composite samples must be investigated.This paper examines the deformation characteristics and damage evolution of six types of BPB composite samples using a digital speckle correlation method under uniaxial compression conditions.A new damage evolution equation was established on the basis of the input strain energy and dissipated strain energy at the peak stress.The prevention and control mechanisms of the backfilling body on the coal pillar instability were discussed.The results show that the deformation localization and macroscopic cracks of the BPB composite samples first appeared at the coal-backfilling interface,and then expanded to the backfilling elements,ultimately appearing in the coal elements.The elastic strain energy in the BPB composite samples reached a maximum at the peak stress,whereas the dissipated energy continued to accumulate and increase.The damage evolution curve and equation agree well with the test results,providing further understanding of instability prevention and the control mechanisms of the BPB composite samples.The restraining effect on the coal pillar was gradually reduced with decreasing backfilling body element's volume ratio,and the BPB composite structure became more vulnerable to failure.This research is expected to guide the design,stability monitoring,instability prevention,and control of BPB structures in pillar-side cemented paste backfilling mining.展开更多
Identifying patterns,recognition systems,prediction methods,and detection methods is a major challenge in solving different medical issues.Few categories of devices for personal and professional assessment of body com...Identifying patterns,recognition systems,prediction methods,and detection methods is a major challenge in solving different medical issues.Few categories of devices for personal and professional assessment of body composition are available.Bioelectrical impedance analyzer is a simple,safe,affordable,mobile,non-invasive,and less expensive alternative device for body composition assessment.Identifying the body composition pattern of different groups with varying age and gender is a major challenge in defining an optimal level because of the body shape,body mass,energy requirements,physical fitness,health status,and metabolic profile.Thus,this research aims to identify the statistical medical pattern recognition of body composition data by using a bioelectrical impedance analyzer.In previous studies,a pattern was identified for four indicators that concern body composition(e.g.,body mass index(BMI),body fat,muscle mass,and total body water).The novelty of our study is the fact that we identified a recognition pattern by using medical statistical methods for a body composition that contains seven indicators(e.g.,body fat,visceral fat,BMI,muscle mass,skeletal muscle mass,sarcopenic index,and total body water).The youth that exhibited the body composition pattern identified in our study could be considered healthy.Every deviation of one or more parameters outside the margins of the pattern for body composition could be associated with health issues,and more medical investigations would be needed for a diagnosis.BIA is considered a valid and reliable device to assess body composition along with medical statistical methods to identify a pattern for body composition according to the age,gender,and other relevant parameters.展开更多
Stress intensity factors for a three dimensional rectangular interfacial crack were considered using the body force method. In the numerical calculations, unknown body force densities were approximated by the products...Stress intensity factors for a three dimensional rectangular interfacial crack were considered using the body force method. In the numerical calculations, unknown body force densities were approximated by the products of the fundamental densities and power series; here the fundamental densities are chosen to express singular stress fields due to an interface crack exactly. The calculation shows that the numerical results are satisfied. The stress intensity factors for a rectangular interface crack were indicated accurately with the varying aspect ratio, and bimaterial parameter.展开更多
Currently for the steel tube reinforced concrete composite pile research, although predecessors make a comprehensive research on the composite pile beating performance, design technology, but there are still many prob...Currently for the steel tube reinforced concrete composite pile research, although predecessors make a comprehensive research on the composite pile beating performance, design technology, but there are still many problems have not been solved, such as the steel tube reinforced concrete pile composite interracial force learn performance research is still in the initial stage. In this paper, we mainly discuss the research methods of several interface mechanical properties and propose the possibility of studying the mechanical properties of the steel tube reinforced concrete composite pile by using the principle of ultrasonic speckle.展开更多
文摘Background:The aim of this study was to investigate the influence of marking meth-ods on the outcomes of body composition analysis and provide guidance for the se-lection of marking methods in mouse body composition analysis.Methods:Male C57BL/6J mice aged 6 weeks were randomly assigned for pre-and post-ear tagging measurements.The body composition of the mice was measured using a small animal body composition analyzer,which provided measurements of the mass of fat,lean,and free fluid.Then,the mass of fat,lean and free fluid to body weight ratio was gained.Further data analysis was conducted to obtain the range and coeffi-cient of variation in body composition measurements for each mouse.The distribution of fat and lean tissue in the mice was also analyzed by comparing the fat-to-lean ratio.Results:(1)The mass of all body composition components in the ear tagging group was significantly lower than that in the control group.(2)There was a significant in-crease in the range and coefficient of variation of body composition measurements between the ear tagging group and the control group.(3)The fat-to-lean ratio in the ear tagging group was significantly lower than that in the control group.Conclusions:Ear tagging significantly lowered the results of body composition analy-sis in mice and higher the results of measurement error.Therefore,ear tagging should be avoided as much as possible when conducting body composition analysis experi-ments in mice.
基金supported by the Shanxi Science and Technology Major Project (No.20201102004)the Distinguished Youth Funds of National Natural Science Foundation of China (No.51925402)+2 种基金the National Natural Science Foundation of China (Nos.52174125,52004171,and 51904203)the Outstanding Youth Cultivation Project in Shanxi Province,China (No.202103021222008)the Key Science and Technology Innovation Team of“1331”Project in Shanxi Province,China,and the Open Fund Project of Key Laboratory of Mining Disaster Prevention and Control (No.MDPC202004)。
文摘A backfilling body-coal pillar-backfilling body(BPB)structure formed by pillar-side cemented paste backfilling can bear overburden stress and ensure safe mining.However,the failure response of BPB composite samples must be investigated.This paper examines the deformation characteristics and damage evolution of six types of BPB composite samples using a digital speckle correlation method under uniaxial compression conditions.A new damage evolution equation was established on the basis of the input strain energy and dissipated strain energy at the peak stress.The prevention and control mechanisms of the backfilling body on the coal pillar instability were discussed.The results show that the deformation localization and macroscopic cracks of the BPB composite samples first appeared at the coal-backfilling interface,and then expanded to the backfilling elements,ultimately appearing in the coal elements.The elastic strain energy in the BPB composite samples reached a maximum at the peak stress,whereas the dissipated energy continued to accumulate and increase.The damage evolution curve and equation agree well with the test results,providing further understanding of instability prevention and the control mechanisms of the BPB composite samples.The restraining effect on the coal pillar was gradually reduced with decreasing backfilling body element's volume ratio,and the BPB composite structure became more vulnerable to failure.This research is expected to guide the design,stability monitoring,instability prevention,and control of BPB structures in pillar-side cemented paste backfilling mining.
基金the APC was funded by“Stefan cel Mare”University of Suceava,Romania。
文摘Identifying patterns,recognition systems,prediction methods,and detection methods is a major challenge in solving different medical issues.Few categories of devices for personal and professional assessment of body composition are available.Bioelectrical impedance analyzer is a simple,safe,affordable,mobile,non-invasive,and less expensive alternative device for body composition assessment.Identifying the body composition pattern of different groups with varying age and gender is a major challenge in defining an optimal level because of the body shape,body mass,energy requirements,physical fitness,health status,and metabolic profile.Thus,this research aims to identify the statistical medical pattern recognition of body composition data by using a bioelectrical impedance analyzer.In previous studies,a pattern was identified for four indicators that concern body composition(e.g.,body mass index(BMI),body fat,muscle mass,and total body water).The novelty of our study is the fact that we identified a recognition pattern by using medical statistical methods for a body composition that contains seven indicators(e.g.,body fat,visceral fat,BMI,muscle mass,skeletal muscle mass,sarcopenic index,and total body water).The youth that exhibited the body composition pattern identified in our study could be considered healthy.Every deviation of one or more parameters outside the margins of the pattern for body composition could be associated with health issues,and more medical investigations would be needed for a diagnosis.BIA is considered a valid and reliable device to assess body composition along with medical statistical methods to identify a pattern for body composition according to the age,gender,and other relevant parameters.
文摘Stress intensity factors for a three dimensional rectangular interfacial crack were considered using the body force method. In the numerical calculations, unknown body force densities were approximated by the products of the fundamental densities and power series; here the fundamental densities are chosen to express singular stress fields due to an interface crack exactly. The calculation shows that the numerical results are satisfied. The stress intensity factors for a rectangular interface crack were indicated accurately with the varying aspect ratio, and bimaterial parameter.
文摘Currently for the steel tube reinforced concrete composite pile research, although predecessors make a comprehensive research on the composite pile beating performance, design technology, but there are still many problems have not been solved, such as the steel tube reinforced concrete pile composite interracial force learn performance research is still in the initial stage. In this paper, we mainly discuss the research methods of several interface mechanical properties and propose the possibility of studying the mechanical properties of the steel tube reinforced concrete composite pile by using the principle of ultrasonic speckle.