Introduction: Ventricular septal defect (VSD) is the most common congenital heart disease of all congenital heart defects. The aim of this study was to investigate the echographic, therapeutic and evolutionary aspects...Introduction: Ventricular septal defect (VSD) is the most common congenital heart disease of all congenital heart defects. The aim of this study was to investigate the echographic, therapeutic and evolutionary aspects of ventricular septal defects (VSD) in the general cardiology department of the Hôpital National Ignace Deen. Methods: A retrospective data collection was carried out from January 2018 to December 2023 including 85 cases of isolated IVC was performed. The variables studied were epidemiological, clinical, paraclinical, therapeutic and evolutionary. Results: Of the 320 patients seen during the study period for congenital heart disease, 85 (26.556%) were isolated IVCs. Age at diagnosis ranged from 3 months to 16 years, with an average age of 3.59 years. The most represented ethnic group was the Fulani (50.58%). The 8.24% came from consanguineous marriage versus 22.35%. 91.76% of children had a history of bronchitis. The most common clinical signs found were systolic murmur (90.58%), growth retardation (51.76%). Only 4 cases (4.70%) had a malformation associated with IVC represented by DiGeorges disease (2.35%) and trisomy 21 (2.35%). Nearly half the patients had type IIb VIC (44.71%). The other half were represented by type 1 (18.82%), type IIa (20%), type III (10.59%) and type IV (5.88%). According to site more than two-thirds of VICs (71.64%) were perimembranous in location, followed by infundibular (16.47%) and muscular (11.76%) VICs. In our study 55.29% presented an indication for both surgical intervention and medical treatment, while 16.47% required only medical treatment. In contrast, 28.23% were placed under exclusive surveillance. Of the 47 patients for whom surgery was indicated, 29 (61.17%) underwent surgical repair, while 18 (38.83%) were awaiting confirmation for surgery. Conclusion: VIC is the most common congenital heart disease. An early detection strategy and the establishment of specialized centers could improve the outcome of these children.展开更多
Background:Ventricular septal defect(VSD)is the most common congenital heart disease.Transcatheter VSD closure is an effective treatment for patients with muscular and perimembranous VSD.However,there is a limit data ...Background:Ventricular septal defect(VSD)is the most common congenital heart disease.Transcatheter VSD closure is an effective treatment for patients with muscular and perimembranous VSD.However,there is a limit data for outlet VSD,especially impact to the aortic valve leaflet after transcatheter closure.This study aims to assess the outcomes of transcatheter closure of the outlet-type ventricular septal defect(OVSD)after 1 postoperative year.Methods:A retrospective study was performed including 50 patients who underwent transcatheter(n=25)and surgical(n=25)OVSD closure during the exact time frame at two medical centres.Results:The median age and body weight of patients in the transcatheter group were significantly higher than those of patients in the surgical group(7.0 vs.2.8 years;27.0 vs.11.4 kg;p<0.01).The defect size in the surgical group was significantly larger than that in the transcatheter group(5.0 vs.3.0 mm;p<0.01).All OVSD patients have successful transcatheter closure(100%)as effective as surgical closure.Less than small residual shunt was present 20%and 8%immediately after the procedure in the transcatheter and surgical groups(p=0.50),which decreased to 12%and 4%at the 1-year follow-up(p=0.61),respectively.No incidence of complete atrioventricular block and other complications was observed in both groups,and no significant differences were noted in the new onset or worsening of the aortic regurgitation in both groups(p=1.0).Conclusions:Transcatheter treatment could be effectively and safely achieved for OVSD closure at 1-year follow-up.展开更多
Background:There is no gold standard sedation method for pediatric cardiac catheterization.In congenital heart diseases with intracardiac shunts,hemodynamic parameters are prone to change depending on the ventilation ...Background:There is no gold standard sedation method for pediatric cardiac catheterization.In congenital heart diseases with intracardiac shunts,hemodynamic parameters are prone to change depending on the ventilation conditions and anesthetics,although few studies have examined these effects.The purpose of this study was to investigate the effects of two different sedation methods on the hemodynamic parameters.Methods:This study retrospectively evaluated consecutive patients with ventricular septal defect(VSD)below 1 year of age who underwent cardiac catheterization at Aichi Children’s Health and Medical Center,who were divided into age-and VSD diameter-matched general anesthesia(GA)and monitored anesthesia care(MAC)under the natural airway groups(n=40 each),for comparison of hemodynamic parameters.Results:In the GA group,arterial blood pH and arterial partial pressure of oxygen were significantly higher(p<0.01),whereas arterial partial pressure of carbon dioxide was significantly lower than in the MAC group(p<0.01).Mean pulmonary artery pressure(p<0.05)and systemic blood pressure(p<0.01)were lower in the GA group.Pulmonary vascular resistance index(p<0.01)and systemic vascular resistance index(p<0.01)were also significantly lower in the GA group than the MAC group.There were no significant differences in pulmonary blood flow index,systemic blood flow index,and pulmonary/systemic blood flow ratio between the two groups.Conclusions:Cardiac catheterization under GA in VSD patients results in different hemodynamic parameters compared to that under MAC.In particular,when using pulmonary artery pressure and pulmonary vascular resistance measured under GA for judgment regarding the surgical indications or perioperative management,consideration should be given to the fact that these parameters might be lower compared to those measured under MAC.展开更多
Objective:This study was designed to determine the long-term safety and efficacy of using the Amplatzer Duct Occluder II(ADO II)for the closure of various ventricular septal defects(VSDs).Methods:From January 2011 to ...Objective:This study was designed to determine the long-term safety and efficacy of using the Amplatzer Duct Occluder II(ADO II)for the closure of various ventricular septal defects(VSDs).Methods:From January 2011 to December 2019,selected VSD patients were treated through transcatheter intervention using ADO II occluders.The closure results and complications from 188 patients,involving 167 perimembranous ventricular septal defects(pmVSDs),9 intracristal VSDs,11 post surgery residual shunts and 1 post closure residual shunt with the mean outlet diameter3.1±0.8 mm under angiography,were enrolled in this study.Results:The success rate was 98.9%for all procedures.During the median 77-month follow-up period,no cases of complete atrioventricular block(cAVB),infective endocarditis or death occurred.One major adverse event(0.5%)was recorded:cerebrovascular accident occurred 1 day after the procedure in one patient who was transferred to the neurology department.The residual shunt rate was 44.6%,which was the most common minor adverse event.The cardiac conduction block rate was 4.3%.Specifically,one pmVSD patient developed intermittent LBBB during the 28-month follow-up.There were 3 patients(1.6%)with new-onset mild tricuspid insufficiency,and the insufficiency degree was stable during follow-up.There was no new-onset aortic insufficiency that occurred.Conclusions:Transcatheter closure of pmVSDs,some intracristal VSDs,some postsurgery or postclosure residual shunts using ADO II occluders were both safe and effective and yielded excellent long-term results in selected patients.展开更多
Background:The optimal surgical timing and clinical outcomes of ventricular septal defect(VSD)closure in neo-nates remain unclear.We aimed to evaluate the clinical outcomes of VSD closure in neonates(age≤30 days).Met...Background:The optimal surgical timing and clinical outcomes of ventricular septal defect(VSD)closure in neo-nates remain unclear.We aimed to evaluate the clinical outcomes of VSD closure in neonates(age≤30 days).Methods:We retrospectively reviewed 50 consecutive neonates who underwent VSD closure for isolated VSDs between August 2003 and June 2021.Indications for the procedure included congestive heart failure/failure to thrive and pulmonary hypertension.Major adverse events(MAEs)were defined as the composite of all-cause mortality,reoperation,persistent atrioventricular block,and significant(≥grade 2)valvular dysfunction.Results:The median age and body weight at operation were 26.0 days(interquartile range[IQR],18.8–28.3)and 3.7 kg(IQR,3.3–4.2),respectively.The median follow-up duration was 110.4 months(IQR,56.8–165.0).Seven patients required preoperative respiratory support,andfive had significant(≥grade 2)preoperative valvular dysfunction.One early mortality occurred due to irreversible cardiogenic shock;no late mortality was observed.One reopera-tion was due to hemodynamically significant residual VSD at 103.8 months postoperatively.The overall survival,freedom from reoperation,and freedom from MAE at 15-years were 98.0%,96.3%,and 94.4%,respectively.Pre-operative mechanical ventilation was associated with a longer duration of postoperative mechanical ventilation(p<0.001)and a longer length of intensive care unit stay(p<0.001).Conclusions:VSD closure with favorable outcomes without morbidities is feasible even in neonates.However,neonates requiring preoperative respiratory support may require careful postoperative management considering the long-term postoperative risks.Overall,surgical VSD closure might be indicated earlier in neonates with respiratory compromise.展开更多
Introduction:Transcatheter closure is an alternative to ventricular septal defect(VSD)occlusion surgery.Nit-Occlud LêVSD coil is a new device yet to be evaluated.The study aimed to evaluate immediate and midterm ...Introduction:Transcatheter closure is an alternative to ventricular septal defect(VSD)occlusion surgery.Nit-Occlud LêVSD coil is a new device yet to be evaluated.The study aimed to evaluate immediate and midterm results after transcatheter closure with the Nit-Occlud LêVSD device.Methods:The retrospective analysis included 30 patients with VSD referred for closure during the period from October 2015 to December 2020.Results:At the time of intervention,the patients’mean age and body weights were 7.5±5.6 years and 29.3±19.1 kg.The majority of the defects had perimembranous location(24/30),four defects had muscular and two outlet subaortic position.The mean effective right-side diameter of the VSDs was 3.6±1.3 mm.Single ventricular fibrillation,device embolization,and hemolysis developed in different patients and were successfully treated.None of the patients had a complete atrioventricular block.The coil was successfully placed in 25/30(83.3%)patients.The majority of the devices were 10 mm×6 mm(11/25)and 12 mm×8 mm(8/25)in size.Two patients required the implantation of a second device.The follow-up period was 2.1±1.4 years.Complete VSD closure was achieved in 48%of cases immediately after the intervention,74%during 2.1±1.6 months after the procedure,and 81%over follow-up.The remaining patients had a trivial residual defect.During the follow-up,approximately one-third of patients developed trivial aortic and mitral valve regurgitation,and half of the patients acquired trace/mild tricuspid regurgitation.Standardized(z-score)left ventricular end-diastolic diameter(0.15±0.37 vs.0.92±0.82,p=0.005)and left atrium dimension(0.47±0.58 vs.1.89±1.11,p=0.005),as well as the left atrium to aortic root ratio(1.2±0.1 vs.1.4±0.2,p=0.005)showed a significant decrease over follow-up related to the period before intervention.Conclusion:Intervention with Nit-OccludLêVSD coil showed appropriate results regarding VSD closure rate,complications,and chamber remodeling.The introduction of this device into clinical practice is a significant step forward in transcatheter perimembranous VSD occlusion.展开更多
Objective:To evaluate the feasibility,safety and efficacy of transcathcter closure of ventricular septal defect(VSD)in patients with aortic valve prolapse(AVP)and mild aortic regurgitation(AR).Methods:Between January ...Objective:To evaluate the feasibility,safety and efficacy of transcathcter closure of ventricular septal defect(VSD)in patients with aortic valve prolapse(AVP)and mild aortic regurgitation(AR).Methods:Between January 2008 and July 2014,transcatheter closure of VSD was attempted in 65 patients.Results:The total intermediate closure successful rate in all subjects was 96.9%.During the perioperative period,no death,major bleeding,pericardial tamponade,occluder dislodgement,residual shunt or hemolysis occurred.Two procedures had been forced to suspend due to significant aggregation of device related aortic regurgitation,three cases of transient complete left bundle branch block occurred but did not sustain.At 1-year followup,no patients had residual shunts and complications.Furthermore,grade of residual AR were relieved in 61.9%(39/63)cases and degree of AVP were ameliorated in 36.5%(23/63)patients;Conclusions:Transcatheter closure VSD in selected patients with AVP and mild AR is technically feasible and highly effective.Long term safety and efficacy needs to be assessed.展开更多
Background: Perimembranous ventricular septal defect combined with right coronary cusp bulge generally should be treated with surgical thoracotomy, owing to the potential aortic regurgitation. However, the minimally i...Background: Perimembranous ventricular septal defect combined with right coronary cusp bulge generally should be treated with surgical thoracotomy, owing to the potential aortic regurgitation. However, the minimally invasive method of transcatheter closure has always attracted the attention of cardiologists and patients. The present study aimed to apply transcatheter occlusion in treating ventricular septal defect with right coronary cusp bulge and further evaluate the clinical effect through follow-up. Materials and methods: A total of 40 children diagnosed as having a ventricular septal defect with right coronary cusp bulge, examined using transthoracic echocardiography and cardiovascular angiography, were enrolled in this study. The ventricular septal defects were closed by placing occluders through transcatheter occlusion treatment. During the operation process, the children underwent angiography and transthoracic echocardiography examinations to check the position of the occlude and the extent of aortic regurgitation. The influence of occlusion on the conduction system was evaluated using a surface electrocardiogram. The children were followed up after their procedures. Results: All 40 patients were immediately and successfully occluded. Three patients with filament residual shunts were observed during the operations. No major surgical complications occurred during the perioperative period. During the follow-up period, the positions of all the occluders were good, the residual shunts in the three patients disappeared, and no new or aggravated aortic regurgitation occurred. Electrocardiogram did not reveal any atrioventricular blocks. Only one patient suffered from an incomplete right bundle branch block. Conclusions: Children diagnosed with ventricular septal defect combined with right coronary cusp bulge could be considered for transcatheter occlusion. With appropriate indications and methods, the effect may be favorable.展开更多
BACKGROUND The off-label use of various devices has been reported for the transcatheter closure of perimembranous ventricular septal defects(PmVSD) because of serious complications, such as heart block and tricuspid r...BACKGROUND The off-label use of various devices has been reported for the transcatheter closure of perimembranous ventricular septal defects(PmVSD) because of serious complications, such as heart block and tricuspid regurgitation(TR),associated with conventional ventricular septal defect devices. However, whether certain defects such as PmVSD with abnormally attached tricuspid are fit for interventional treatment is still disputable.AIM To explore the feasibility and safety of transcatheter closure of PmVSD with abnormally attached tricuspid chordae tendineae using an improved patent ductus arteriosus(PDA) occluder.METHODS We retrospectively analyzed 20 patients diagnosed with PmVSD with abnormally attached tricuspid chordae tendineae who underwent interventional treatment using an improved PDA occluder at our center from January 2012 to January 2016. Baseline characteristics and procedural and follow-up data were analyzed.RESULTS All 20 patients achieved procedure success. No heart block occurred during the operation. One patient had a transient complete right bundle branch block within48 h post-procedure and reverted to normal rhythm after intravenous injections of dexamethasone for 3 d. For all 20 patients, no residual shunt was observed by transthoracic echocardiography post-procedure. During the average follow-up period of 2.4 years, no severe TR was observed.CONCLUSION Using of the improved PDA occluder for the transcatheter closure of PmVSD with abnormally attached tricuspid chordae tendineae is a safe and promising treatment option. However, long-term follow-up in a large group of patients is still warranted.展开更多
A 54-year-old female patient with congenital heart disease had a persistent complete left bundle branch block three months after closure by an Amplatzer ventricular septal defect occluder. Nine months later, the patie...A 54-year-old female patient with congenital heart disease had a persistent complete left bundle branch block three months after closure by an Amplatzer ventricular septal defect occluder. Nine months later, the patient suffered from chest distress, palpitation, and sweating at daily activities, and her 6-min walk distance decreased significantly (155 m). Her echocardiography showed increased left ventricular end-diastolic diameter with left ventricular ejection fraction of 37%. Her symptoms reduced significantly one week after received cardiac resynchronization therapy. She had no symptoms at daily activities, and her echo showed left ventricular ejection fraction of 46%and 53%. Moreover, left ventricular end-diastolic diameter decreased 6 and 10 months after cardiac resynchronization therapy, and 6-min walk dis-tance remarkably increased. This case demonstrated that persistent complete left bundle branch block for nine months after transcatheter closure with ventricular septal defect Amplatzer occluder could lead to left ventricular enlargement and a significant decrease in left ventricular systolic function. Cardiac resynchronization therapy decreased left ventricular end-diastolic diameter and increased left ventricular ejection fraction, thereby improving the patient’s heart functions.展开更多
Ruptured sinus of Valsalva is very uncommon,and is < 1% of all congenital defects.The incidence ranges from 0.1%-3.5%.There is a male to female predominance of 4:1,with the highest incidence in the Asian population...Ruptured sinus of Valsalva is very uncommon,and is < 1% of all congenital defects.The incidence ranges from 0.1%-3.5%.There is a male to female predominance of 4:1,with the highest incidence in the Asian population.Higher incidence is also seen in patients with Marfan's syndrome and Ehlers Danlos syndrome.There is a higher association of ruptured sinus of Valsalva with ventricular septal defect(VSD),aortic stenosis,and bicuspid valve defect.While most patients with VSD often have rupture of their right coronary sinus of Valsalva into the right ventricle due to poor structural integrity,we present a rare case of a patient with VSD who had rupture of his noncoronary sinus of Valsalva into the right atrium.展开更多
Current permanent right ventricular and right atrial endocardial pacing leads are implanted utilizing a central lumen stylet. Right ventricular apex pacing initiates an abnormal asynchronous electrical activation patt...Current permanent right ventricular and right atrial endocardial pacing leads are implanted utilizing a central lumen stylet. Right ventricular apex pacing initiates an abnormal asynchronous electrical activation pattern, which results in asynchronous ventricular contraction and relaxation. When pacing from right atrial appendage, the conduction time between two atria will be prolonged, which results in heterogeneity for both depolarization and repolarization. Six patients with Class Ⅰ indication for permanent pacing were implanted with either single chamber or dual chamber pacemaker. The SelectSecure 3830 4-French (Fr) lumenless lead and the SelectSite C304 8.5-Fr steerable catheter-sheath (Medtronic Inc., USA) were used. Pre-selected pacing sites included inter-atrial septum and right ventricular outflow tract, which were defined by ECG and fluoroscopic criteria. All the implanting procedures were successful without complication. Testing results (mean atrial pacing threshold: 0.87 V; mean P wave amplitude: 2.28 mV; mean ventricular pacing threshold: 0.53V; mean R wave amplitude: 8.75 mV) were satisfactory. It is concluded that implantation of a 4-Fr lumenless pacing lead by using a streerable catheter-sheath to achieve inter-atrial septum or right ventricular outflow tract pacing is safe and feasible.展开更多
The corrected shunt flow rate (Fc ) and corrected defect orifice area (Ac) were calculated by modified equation F= 2πR2 ×(NL-VL.voT× Sinθ) in 23 patients with single membranous ventricular septal defect, i...The corrected shunt flow rate (Fc ) and corrected defect orifice area (Ac) were calculated by modified equation F= 2πR2 ×(NL-VL.voT× Sinθ) in 23 patients with single membranous ventricular septal defect, in order to correct the ef fect of left ventricular outflow on flow convergence region on the left septa1 sur-face. The results indicated that F. was closely correlated with Qp -Q5. and Qp/Q5measured by pulsed wave Doppler (r = 0. 95 and r = 0. 81 respectively, P < 0.001 ). And the correlation between A. and the diameter of defect (Dd) rneasureddirectly in two-dimensional views was better than that between uncorrected defectorifice area (A ) and the Dd (r = O- 98 and O- 69, respectively, P< O. Ool ). Theshunt flow rate calculated by ideal equation F= 2ffR2 X NL overestimated the actu-al shunt flow rate in ventricular septal defect, especialIy in mernbranous type.Our study concluded that F. can be used for a more accurate eva1uation of theshunt severity of ventricular septal defect.展开更多
The ventricular septum separates the right and left ventricles and thus is part of both ventricles.It is directed obliquely backward to the right,and curved with the convexity toward the right ventricle;it must be emp...The ventricular septum separates the right and left ventricles and thus is part of both ventricles.It is directed obliquely backward to the right,and curved with the convexity toward the right ventricle;it must be emphasized that the total cardiac septum has a complex,longitudinal twist and does not lie in any single plane.Its upper and posterior part,is thin and fibrous,and is termed the membranous ventricular septum.The greater portion of the septum is thick and muscular and constitutes the muscular ventricular septum.The ventricular septum consists of two layers,a thin layer on the RV side and a thicker layer on the LV side[1].The major septal arteries tend to run between these two layers.展开更多
Objective To research the expression of endothelin-1 (ET-1) in vascular of lung, endocardium and myocardial vascular of congenital heart disease (CHD) ventricular septal defect (VSD) with pulmonary hypertension (PH...Objective To research the expression of endothelin-1 (ET-1) in vascular of lung, endocardium and myocardial vascular of congenital heart disease (CHD) ventricular septal defect (VSD) with pulmonary hypertension (PH). Methods The Streptavidin-peroxidase (SP) immunoassay was used to measure the expression of ET-1 in pulmonary arteriola, pulmonary veinlet, endocardium and endangium of vasa coronary of 20 cases VSD of CHD with PH, and contrast the expression level of these 20 cases VSD of CHD with PH. Results The expression of ET-1 PH patients in pulmonary arteriola, endocardium, and endangium of vasa coronary was much higher than that of the control group (P<0.05), but there was no significance variance in expression level of pulmonary veinlet between two groups (P>0.05). Conclusion If VSD of CHD was accompany with PH, the degree of PH has a positive correlation with the amount of ET-1 in pulmonary arteriola, ET-1 may be the cause of dynamic PH, and also the acceleration factor of the PH. However, the amount of ET-1 in endocardium and endangium of vasa coronary, may have significant connection with the myocardium hypertrophy in dynamic PH.展开更多
We present a case of an isolated large ventricular septal defect (VSD) following blunt chest trauma in a motor vehicle accident in the patient with preexisting mechanical mitral valve. Transthoracic echocardiography r...We present a case of an isolated large ventricular septal defect (VSD) following blunt chest trauma in a motor vehicle accident in the patient with preexisting mechanical mitral valve. Transthoracic echocardiography revealed a large muscular VSD with significant left to right shunt along with septal edema. Surgical repair was performed in view of Qp:Qs of 2.5 with significant hemodynamic instability despite intra-aortic balloon pump. The ventricular septal defect was found in apical muscular portion of the interventricular septum, which was closed through left ventriculotomy. We here discuss the possible mechanisms of damage and importance of timely surgery. To conclude, minor looking external injury might contain devastating damage inside, especially with patients on anti-coagulant therapy.展开更多
We present a case of transcatheter closure of a traumatic ventricular septal defect (VSD), in which simultaneous 3-dimensional (3D) transesophageal echocardiography (TEE) and angiography played a critical role in defe...We present a case of transcatheter closure of a traumatic ventricular septal defect (VSD), in which simultaneous 3-dimensional (3D) transesophageal echocardiography (TEE) and angiography played a critical role in defect sizing, device selection, and procedural guidance.展开更多
Background: There is a need for data on epidemiological, clinical and therapeutic aspects of ventricular septal defect among children in?Sub-Saharan Africa. Objective: The aim of this study was to determine the preval...Background: There is a need for data on epidemiological, clinical and therapeutic aspects of ventricular septal defect among children in?Sub-Saharan Africa. Objective: The aim of this study was to determine the prevalence, epidemioclinical, echocardiographic, therapeutic and evolutionary aspects of ventricular septal defects (VSD) in the pediatric department of the University Hospital Center (CHUSS) of Bobo-Dioulasso. Methods: This study was a descriptive cross-sectional study, conducted from November 2013 to December 2016. All children aged 1 to 179 months seen at the pediatric consultation in CHUSS were included. CIV was confirmed with Doppler echocardiography. Results: Out of 36,240 children who received consultation in the pediatric ward of CHUSS during the study period, one hundred (100) cases of them had congenital heart disease representing a hospital prevalence of 2.76%. This was diagnosed with Doppler echocardiography. Of these, 88% were VSD isolated or associated with other cardiac malformations. Isolated form was reported in 54.3% of cases. The average?age at diagnosis was 39.6 months. The sex ratio was 1.05. Perimembranous topography and hemodynamic type 2 were the highest, representing 56.8% and 35.2% respectively. The indication for surgical repair was recommended for 81.8% of the cases, but only 9.7% of these cases benefited from cardiac surgery. The rest were for medicalcare with a high proportion of lost to follow-up (48.9%). Conclusion: VSD is the most common congenital heart disease. Its care is mainly surgical. This cardiac surgery is non-existent in Burkina Faso. The design of multidisciplinary strategies associated with an optimization of the means of the countries of Sub-Saharan Africa could improve the management of this cardiopathy.展开更多
Background:Communication between the right pulmonary artery(RPA)and left atrium(LA)is a rare cause of central cyanosis in pediatric patients.Case presentation:We describe a 3-year-old female patient with an oxygen sat...Background:Communication between the right pulmonary artery(RPA)and left atrium(LA)is a rare cause of central cyanosis in pediatric patients.Case presentation:We describe a 3-year-old female patient with an oxygen saturation of 70%at admission.The echocardiogram indicated an abnormal color flow Doppler in the LA and she underwent standard cardiac catheterization.The angiography of pulmonary artery revealed a 7.4 mm×7.6 mm fistula between the RPA and LA and achieved successful closure using ventricular septal defect occlusion.Conclusion:The fistula between pulmonary artery and left atrium is an extremely rare but treatable congenital defect.It should be considered in differential diagnosis of cyanosis in children.展开更多
Objective:To evaluate the efficacy of Amplatzer duct occluder II(ADO II)in the treatment of perimembranous ventricular septal defect(pmVSD)in children.Methods:Between June 2017 and June 2020,13 patients with pmVSD had...Objective:To evaluate the efficacy of Amplatzer duct occluder II(ADO II)in the treatment of perimembranous ventricular septal defect(pmVSD)in children.Methods:Between June 2017 and June 2020,13 patients with pmVSD had attempted transcatheter closure using ADO II,seven of patients were used antegrade approach and six of them were used retrograde approach.Results:There were 8 males and 5 females,age from 1 to 7 years,weight from 10.5 to 31.0 kg,and VSD size from 2.0 to 4.0 mm.Procedure was successful in all cases with the outer diameter of the occluders ranging from 4 to 6 mm.No aortic,tricuspid regurgitation or residual shunt was found in the immediate ultrasound assessment.No arrhythmia was observed in the Holter monitoring 3 days after the intervention.Discharge echocardiography indicated complete shunt closure.No evidence of occluder prolapse,malignant arrhythmia,or intensed valve regurgitation was seen on a median follow-up of 18 months(range,6 to 36 months).Conclusions:Based on our experience,ADO II showed good efficacy in the early and middle stages of pediatric pmVSD closures.展开更多
文摘Introduction: Ventricular septal defect (VSD) is the most common congenital heart disease of all congenital heart defects. The aim of this study was to investigate the echographic, therapeutic and evolutionary aspects of ventricular septal defects (VSD) in the general cardiology department of the Hôpital National Ignace Deen. Methods: A retrospective data collection was carried out from January 2018 to December 2023 including 85 cases of isolated IVC was performed. The variables studied were epidemiological, clinical, paraclinical, therapeutic and evolutionary. Results: Of the 320 patients seen during the study period for congenital heart disease, 85 (26.556%) were isolated IVCs. Age at diagnosis ranged from 3 months to 16 years, with an average age of 3.59 years. The most represented ethnic group was the Fulani (50.58%). The 8.24% came from consanguineous marriage versus 22.35%. 91.76% of children had a history of bronchitis. The most common clinical signs found were systolic murmur (90.58%), growth retardation (51.76%). Only 4 cases (4.70%) had a malformation associated with IVC represented by DiGeorges disease (2.35%) and trisomy 21 (2.35%). Nearly half the patients had type IIb VIC (44.71%). The other half were represented by type 1 (18.82%), type IIa (20%), type III (10.59%) and type IV (5.88%). According to site more than two-thirds of VICs (71.64%) were perimembranous in location, followed by infundibular (16.47%) and muscular (11.76%) VICs. In our study 55.29% presented an indication for both surgical intervention and medical treatment, while 16.47% required only medical treatment. In contrast, 28.23% were placed under exclusive surveillance. Of the 47 patients for whom surgery was indicated, 29 (61.17%) underwent surgical repair, while 18 (38.83%) were awaiting confirmation for surgery. Conclusion: VIC is the most common congenital heart disease. An early detection strategy and the establishment of specialized centers could improve the outcome of these children.
文摘Background:Ventricular septal defect(VSD)is the most common congenital heart disease.Transcatheter VSD closure is an effective treatment for patients with muscular and perimembranous VSD.However,there is a limit data for outlet VSD,especially impact to the aortic valve leaflet after transcatheter closure.This study aims to assess the outcomes of transcatheter closure of the outlet-type ventricular septal defect(OVSD)after 1 postoperative year.Methods:A retrospective study was performed including 50 patients who underwent transcatheter(n=25)and surgical(n=25)OVSD closure during the exact time frame at two medical centres.Results:The median age and body weight of patients in the transcatheter group were significantly higher than those of patients in the surgical group(7.0 vs.2.8 years;27.0 vs.11.4 kg;p<0.01).The defect size in the surgical group was significantly larger than that in the transcatheter group(5.0 vs.3.0 mm;p<0.01).All OVSD patients have successful transcatheter closure(100%)as effective as surgical closure.Less than small residual shunt was present 20%and 8%immediately after the procedure in the transcatheter and surgical groups(p=0.50),which decreased to 12%and 4%at the 1-year follow-up(p=0.61),respectively.No incidence of complete atrioventricular block and other complications was observed in both groups,and no significant differences were noted in the new onset or worsening of the aortic regurgitation in both groups(p=1.0).Conclusions:Transcatheter treatment could be effectively and safely achieved for OVSD closure at 1-year follow-up.
文摘Background:There is no gold standard sedation method for pediatric cardiac catheterization.In congenital heart diseases with intracardiac shunts,hemodynamic parameters are prone to change depending on the ventilation conditions and anesthetics,although few studies have examined these effects.The purpose of this study was to investigate the effects of two different sedation methods on the hemodynamic parameters.Methods:This study retrospectively evaluated consecutive patients with ventricular septal defect(VSD)below 1 year of age who underwent cardiac catheterization at Aichi Children’s Health and Medical Center,who were divided into age-and VSD diameter-matched general anesthesia(GA)and monitored anesthesia care(MAC)under the natural airway groups(n=40 each),for comparison of hemodynamic parameters.Results:In the GA group,arterial blood pH and arterial partial pressure of oxygen were significantly higher(p<0.01),whereas arterial partial pressure of carbon dioxide was significantly lower than in the MAC group(p<0.01).Mean pulmonary artery pressure(p<0.05)and systemic blood pressure(p<0.01)were lower in the GA group.Pulmonary vascular resistance index(p<0.01)and systemic vascular resistance index(p<0.01)were also significantly lower in the GA group than the MAC group.There were no significant differences in pulmonary blood flow index,systemic blood flow index,and pulmonary/systemic blood flow ratio between the two groups.Conclusions:Cardiac catheterization under GA in VSD patients results in different hemodynamic parameters compared to that under MAC.In particular,when using pulmonary artery pressure and pulmonary vascular resistance measured under GA for judgment regarding the surgical indications or perioperative management,consideration should be given to the fact that these parameters might be lower compared to those measured under MAC.
基金This study was supported by grant from Doctoral Start-Up Foundation of Liaoning Province of China(2019-BS-266).
文摘Objective:This study was designed to determine the long-term safety and efficacy of using the Amplatzer Duct Occluder II(ADO II)for the closure of various ventricular septal defects(VSDs).Methods:From January 2011 to December 2019,selected VSD patients were treated through transcatheter intervention using ADO II occluders.The closure results and complications from 188 patients,involving 167 perimembranous ventricular septal defects(pmVSDs),9 intracristal VSDs,11 post surgery residual shunts and 1 post closure residual shunt with the mean outlet diameter3.1±0.8 mm under angiography,were enrolled in this study.Results:The success rate was 98.9%for all procedures.During the median 77-month follow-up period,no cases of complete atrioventricular block(cAVB),infective endocarditis or death occurred.One major adverse event(0.5%)was recorded:cerebrovascular accident occurred 1 day after the procedure in one patient who was transferred to the neurology department.The residual shunt rate was 44.6%,which was the most common minor adverse event.The cardiac conduction block rate was 4.3%.Specifically,one pmVSD patient developed intermittent LBBB during the 28-month follow-up.There were 3 patients(1.6%)with new-onset mild tricuspid insufficiency,and the insufficiency degree was stable during follow-up.There was no new-onset aortic insufficiency that occurred.Conclusions:Transcatheter closure of pmVSDs,some intracristal VSDs,some postsurgery or postclosure residual shunts using ADO II occluders were both safe and effective and yielded excellent long-term results in selected patients.
基金This retrospective study was approved by the Seoul National University Hospital Institutional Review Board(approval number:H-2106-179-1230).The requirement for informed consent was waived.
文摘Background:The optimal surgical timing and clinical outcomes of ventricular septal defect(VSD)closure in neo-nates remain unclear.We aimed to evaluate the clinical outcomes of VSD closure in neonates(age≤30 days).Methods:We retrospectively reviewed 50 consecutive neonates who underwent VSD closure for isolated VSDs between August 2003 and June 2021.Indications for the procedure included congestive heart failure/failure to thrive and pulmonary hypertension.Major adverse events(MAEs)were defined as the composite of all-cause mortality,reoperation,persistent atrioventricular block,and significant(≥grade 2)valvular dysfunction.Results:The median age and body weight at operation were 26.0 days(interquartile range[IQR],18.8–28.3)and 3.7 kg(IQR,3.3–4.2),respectively.The median follow-up duration was 110.4 months(IQR,56.8–165.0).Seven patients required preoperative respiratory support,andfive had significant(≥grade 2)preoperative valvular dysfunction.One early mortality occurred due to irreversible cardiogenic shock;no late mortality was observed.One reopera-tion was due to hemodynamically significant residual VSD at 103.8 months postoperatively.The overall survival,freedom from reoperation,and freedom from MAE at 15-years were 98.0%,96.3%,and 94.4%,respectively.Pre-operative mechanical ventilation was associated with a longer duration of postoperative mechanical ventilation(p<0.001)and a longer length of intensive care unit stay(p<0.001).Conclusions:VSD closure with favorable outcomes without morbidities is feasible even in neonates.However,neonates requiring preoperative respiratory support may require careful postoperative management considering the long-term postoperative risks.Overall,surgical VSD closure might be indicated earlier in neonates with respiratory compromise.
文摘Introduction:Transcatheter closure is an alternative to ventricular septal defect(VSD)occlusion surgery.Nit-Occlud LêVSD coil is a new device yet to be evaluated.The study aimed to evaluate immediate and midterm results after transcatheter closure with the Nit-Occlud LêVSD device.Methods:The retrospective analysis included 30 patients with VSD referred for closure during the period from October 2015 to December 2020.Results:At the time of intervention,the patients’mean age and body weights were 7.5±5.6 years and 29.3±19.1 kg.The majority of the defects had perimembranous location(24/30),four defects had muscular and two outlet subaortic position.The mean effective right-side diameter of the VSDs was 3.6±1.3 mm.Single ventricular fibrillation,device embolization,and hemolysis developed in different patients and were successfully treated.None of the patients had a complete atrioventricular block.The coil was successfully placed in 25/30(83.3%)patients.The majority of the devices were 10 mm×6 mm(11/25)and 12 mm×8 mm(8/25)in size.Two patients required the implantation of a second device.The follow-up period was 2.1±1.4 years.Complete VSD closure was achieved in 48%of cases immediately after the intervention,74%during 2.1±1.6 months after the procedure,and 81%over follow-up.The remaining patients had a trivial residual defect.During the follow-up,approximately one-third of patients developed trivial aortic and mitral valve regurgitation,and half of the patients acquired trace/mild tricuspid regurgitation.Standardized(z-score)left ventricular end-diastolic diameter(0.15±0.37 vs.0.92±0.82,p=0.005)and left atrium dimension(0.47±0.58 vs.1.89±1.11,p=0.005),as well as the left atrium to aortic root ratio(1.2±0.1 vs.1.4±0.2,p=0.005)showed a significant decrease over follow-up related to the period before intervention.Conclusion:Intervention with Nit-OccludLêVSD coil showed appropriate results regarding VSD closure rate,complications,and chamber remodeling.The introduction of this device into clinical practice is a significant step forward in transcatheter perimembranous VSD occlusion.
基金supported by National Nature Science Foundation of China(NO.81260052)Science and Technology Planning Project of Hainan Province of China(NO.812147)
文摘Objective:To evaluate the feasibility,safety and efficacy of transcathcter closure of ventricular septal defect(VSD)in patients with aortic valve prolapse(AVP)and mild aortic regurgitation(AR).Methods:Between January 2008 and July 2014,transcatheter closure of VSD was attempted in 65 patients.Results:The total intermediate closure successful rate in all subjects was 96.9%.During the perioperative period,no death,major bleeding,pericardial tamponade,occluder dislodgement,residual shunt or hemolysis occurred.Two procedures had been forced to suspend due to significant aggregation of device related aortic regurgitation,three cases of transient complete left bundle branch block occurred but did not sustain.At 1-year followup,no patients had residual shunts and complications.Furthermore,grade of residual AR were relieved in 61.9%(39/63)cases and degree of AVP were ameliorated in 36.5%(23/63)patients;Conclusions:Transcatheter closure VSD in selected patients with AVP and mild AR is technically feasible and highly effective.Long term safety and efficacy needs to be assessed.
基金supported by the National Science Foundation of China(Grant number 81470443)
文摘Background: Perimembranous ventricular septal defect combined with right coronary cusp bulge generally should be treated with surgical thoracotomy, owing to the potential aortic regurgitation. However, the minimally invasive method of transcatheter closure has always attracted the attention of cardiologists and patients. The present study aimed to apply transcatheter occlusion in treating ventricular septal defect with right coronary cusp bulge and further evaluate the clinical effect through follow-up. Materials and methods: A total of 40 children diagnosed as having a ventricular septal defect with right coronary cusp bulge, examined using transthoracic echocardiography and cardiovascular angiography, were enrolled in this study. The ventricular septal defects were closed by placing occluders through transcatheter occlusion treatment. During the operation process, the children underwent angiography and transthoracic echocardiography examinations to check the position of the occlude and the extent of aortic regurgitation. The influence of occlusion on the conduction system was evaluated using a surface electrocardiogram. The children were followed up after their procedures. Results: All 40 patients were immediately and successfully occluded. Three patients with filament residual shunts were observed during the operations. No major surgical complications occurred during the perioperative period. During the follow-up period, the positions of all the occluders were good, the residual shunts in the three patients disappeared, and no new or aggravated aortic regurgitation occurred. Electrocardiogram did not reveal any atrioventricular blocks. Only one patient suffered from an incomplete right bundle branch block. Conclusions: Children diagnosed with ventricular septal defect combined with right coronary cusp bulge could be considered for transcatheter occlusion. With appropriate indications and methods, the effect may be favorable.
文摘BACKGROUND The off-label use of various devices has been reported for the transcatheter closure of perimembranous ventricular septal defects(PmVSD) because of serious complications, such as heart block and tricuspid regurgitation(TR),associated with conventional ventricular septal defect devices. However, whether certain defects such as PmVSD with abnormally attached tricuspid are fit for interventional treatment is still disputable.AIM To explore the feasibility and safety of transcatheter closure of PmVSD with abnormally attached tricuspid chordae tendineae using an improved patent ductus arteriosus(PDA) occluder.METHODS We retrospectively analyzed 20 patients diagnosed with PmVSD with abnormally attached tricuspid chordae tendineae who underwent interventional treatment using an improved PDA occluder at our center from January 2012 to January 2016. Baseline characteristics and procedural and follow-up data were analyzed.RESULTS All 20 patients achieved procedure success. No heart block occurred during the operation. One patient had a transient complete right bundle branch block within48 h post-procedure and reverted to normal rhythm after intravenous injections of dexamethasone for 3 d. For all 20 patients, no residual shunt was observed by transthoracic echocardiography post-procedure. During the average follow-up period of 2.4 years, no severe TR was observed.CONCLUSION Using of the improved PDA occluder for the transcatheter closure of PmVSD with abnormally attached tricuspid chordae tendineae is a safe and promising treatment option. However, long-term follow-up in a large group of patients is still warranted.
文摘A 54-year-old female patient with congenital heart disease had a persistent complete left bundle branch block three months after closure by an Amplatzer ventricular septal defect occluder. Nine months later, the patient suffered from chest distress, palpitation, and sweating at daily activities, and her 6-min walk distance decreased significantly (155 m). Her echocardiography showed increased left ventricular end-diastolic diameter with left ventricular ejection fraction of 37%. Her symptoms reduced significantly one week after received cardiac resynchronization therapy. She had no symptoms at daily activities, and her echo showed left ventricular ejection fraction of 46%and 53%. Moreover, left ventricular end-diastolic diameter decreased 6 and 10 months after cardiac resynchronization therapy, and 6-min walk dis-tance remarkably increased. This case demonstrated that persistent complete left bundle branch block for nine months after transcatheter closure with ventricular septal defect Amplatzer occluder could lead to left ventricular enlargement and a significant decrease in left ventricular systolic function. Cardiac resynchronization therapy decreased left ventricular end-diastolic diameter and increased left ventricular ejection fraction, thereby improving the patient’s heart functions.
文摘Ruptured sinus of Valsalva is very uncommon,and is < 1% of all congenital defects.The incidence ranges from 0.1%-3.5%.There is a male to female predominance of 4:1,with the highest incidence in the Asian population.Higher incidence is also seen in patients with Marfan's syndrome and Ehlers Danlos syndrome.There is a higher association of ruptured sinus of Valsalva with ventricular septal defect(VSD),aortic stenosis,and bicuspid valve defect.While most patients with VSD often have rupture of their right coronary sinus of Valsalva into the right ventricle due to poor structural integrity,we present a rare case of a patient with VSD who had rupture of his noncoronary sinus of Valsalva into the right atrium.
基金supported by a grant form a Program of Science and Technology Development of Hubei Province (2004AA304B09).
文摘Current permanent right ventricular and right atrial endocardial pacing leads are implanted utilizing a central lumen stylet. Right ventricular apex pacing initiates an abnormal asynchronous electrical activation pattern, which results in asynchronous ventricular contraction and relaxation. When pacing from right atrial appendage, the conduction time between two atria will be prolonged, which results in heterogeneity for both depolarization and repolarization. Six patients with Class Ⅰ indication for permanent pacing were implanted with either single chamber or dual chamber pacemaker. The SelectSecure 3830 4-French (Fr) lumenless lead and the SelectSite C304 8.5-Fr steerable catheter-sheath (Medtronic Inc., USA) were used. Pre-selected pacing sites included inter-atrial septum and right ventricular outflow tract, which were defined by ECG and fluoroscopic criteria. All the implanting procedures were successful without complication. Testing results (mean atrial pacing threshold: 0.87 V; mean P wave amplitude: 2.28 mV; mean ventricular pacing threshold: 0.53V; mean R wave amplitude: 8.75 mV) were satisfactory. It is concluded that implantation of a 4-Fr lumenless pacing lead by using a streerable catheter-sheath to achieve inter-atrial septum or right ventricular outflow tract pacing is safe and feasible.
文摘The corrected shunt flow rate (Fc ) and corrected defect orifice area (Ac) were calculated by modified equation F= 2πR2 ×(NL-VL.voT× Sinθ) in 23 patients with single membranous ventricular septal defect, in order to correct the ef fect of left ventricular outflow on flow convergence region on the left septa1 sur-face. The results indicated that F. was closely correlated with Qp -Q5. and Qp/Q5measured by pulsed wave Doppler (r = 0. 95 and r = 0. 81 respectively, P < 0.001 ). And the correlation between A. and the diameter of defect (Dd) rneasureddirectly in two-dimensional views was better than that between uncorrected defectorifice area (A ) and the Dd (r = O- 98 and O- 69, respectively, P< O. Ool ). Theshunt flow rate calculated by ideal equation F= 2ffR2 X NL overestimated the actu-al shunt flow rate in ventricular septal defect, especialIy in mernbranous type.Our study concluded that F. can be used for a more accurate eva1uation of theshunt severity of ventricular septal defect.
文摘The ventricular septum separates the right and left ventricles and thus is part of both ventricles.It is directed obliquely backward to the right,and curved with the convexity toward the right ventricle;it must be emphasized that the total cardiac septum has a complex,longitudinal twist and does not lie in any single plane.Its upper and posterior part,is thin and fibrous,and is termed the membranous ventricular septum.The greater portion of the septum is thick and muscular and constitutes the muscular ventricular septum.The ventricular septum consists of two layers,a thin layer on the RV side and a thicker layer on the LV side[1].The major septal arteries tend to run between these two layers.
文摘Objective To research the expression of endothelin-1 (ET-1) in vascular of lung, endocardium and myocardial vascular of congenital heart disease (CHD) ventricular septal defect (VSD) with pulmonary hypertension (PH). Methods The Streptavidin-peroxidase (SP) immunoassay was used to measure the expression of ET-1 in pulmonary arteriola, pulmonary veinlet, endocardium and endangium of vasa coronary of 20 cases VSD of CHD with PH, and contrast the expression level of these 20 cases VSD of CHD with PH. Results The expression of ET-1 PH patients in pulmonary arteriola, endocardium, and endangium of vasa coronary was much higher than that of the control group (P<0.05), but there was no significance variance in expression level of pulmonary veinlet between two groups (P>0.05). Conclusion If VSD of CHD was accompany with PH, the degree of PH has a positive correlation with the amount of ET-1 in pulmonary arteriola, ET-1 may be the cause of dynamic PH, and also the acceleration factor of the PH. However, the amount of ET-1 in endocardium and endangium of vasa coronary, may have significant connection with the myocardium hypertrophy in dynamic PH.
文摘We present a case of an isolated large ventricular septal defect (VSD) following blunt chest trauma in a motor vehicle accident in the patient with preexisting mechanical mitral valve. Transthoracic echocardiography revealed a large muscular VSD with significant left to right shunt along with septal edema. Surgical repair was performed in view of Qp:Qs of 2.5 with significant hemodynamic instability despite intra-aortic balloon pump. The ventricular septal defect was found in apical muscular portion of the interventricular septum, which was closed through left ventriculotomy. We here discuss the possible mechanisms of damage and importance of timely surgery. To conclude, minor looking external injury might contain devastating damage inside, especially with patients on anti-coagulant therapy.
文摘We present a case of transcatheter closure of a traumatic ventricular septal defect (VSD), in which simultaneous 3-dimensional (3D) transesophageal echocardiography (TEE) and angiography played a critical role in defect sizing, device selection, and procedural guidance.
文摘Background: There is a need for data on epidemiological, clinical and therapeutic aspects of ventricular septal defect among children in?Sub-Saharan Africa. Objective: The aim of this study was to determine the prevalence, epidemioclinical, echocardiographic, therapeutic and evolutionary aspects of ventricular septal defects (VSD) in the pediatric department of the University Hospital Center (CHUSS) of Bobo-Dioulasso. Methods: This study was a descriptive cross-sectional study, conducted from November 2013 to December 2016. All children aged 1 to 179 months seen at the pediatric consultation in CHUSS were included. CIV was confirmed with Doppler echocardiography. Results: Out of 36,240 children who received consultation in the pediatric ward of CHUSS during the study period, one hundred (100) cases of them had congenital heart disease representing a hospital prevalence of 2.76%. This was diagnosed with Doppler echocardiography. Of these, 88% were VSD isolated or associated with other cardiac malformations. Isolated form was reported in 54.3% of cases. The average?age at diagnosis was 39.6 months. The sex ratio was 1.05. Perimembranous topography and hemodynamic type 2 were the highest, representing 56.8% and 35.2% respectively. The indication for surgical repair was recommended for 81.8% of the cases, but only 9.7% of these cases benefited from cardiac surgery. The rest were for medicalcare with a high proportion of lost to follow-up (48.9%). Conclusion: VSD is the most common congenital heart disease. Its care is mainly surgical. This cardiac surgery is non-existent in Burkina Faso. The design of multidisciplinary strategies associated with an optimization of the means of the countries of Sub-Saharan Africa could improve the management of this cardiopathy.
基金This work was supported by a grant from the National Science Foundation of China[Grant No.81700286].
文摘Background:Communication between the right pulmonary artery(RPA)and left atrium(LA)is a rare cause of central cyanosis in pediatric patients.Case presentation:We describe a 3-year-old female patient with an oxygen saturation of 70%at admission.The echocardiogram indicated an abnormal color flow Doppler in the LA and she underwent standard cardiac catheterization.The angiography of pulmonary artery revealed a 7.4 mm×7.6 mm fistula between the RPA and LA and achieved successful closure using ventricular septal defect occlusion.Conclusion:The fistula between pulmonary artery and left atrium is an extremely rare but treatable congenital defect.It should be considered in differential diagnosis of cyanosis in children.
基金The work was financially supported by the National Natural Science Foundation of China(81770316,81970249 to SLP)Shandong Taishan Scholarship(2018 to SLP)and Qingdao Science and Technology Plan(20-3-4-47-nsh).
文摘Objective:To evaluate the efficacy of Amplatzer duct occluder II(ADO II)in the treatment of perimembranous ventricular septal defect(pmVSD)in children.Methods:Between June 2017 and June 2020,13 patients with pmVSD had attempted transcatheter closure using ADO II,seven of patients were used antegrade approach and six of them were used retrograde approach.Results:There were 8 males and 5 females,age from 1 to 7 years,weight from 10.5 to 31.0 kg,and VSD size from 2.0 to 4.0 mm.Procedure was successful in all cases with the outer diameter of the occluders ranging from 4 to 6 mm.No aortic,tricuspid regurgitation or residual shunt was found in the immediate ultrasound assessment.No arrhythmia was observed in the Holter monitoring 3 days after the intervention.Discharge echocardiography indicated complete shunt closure.No evidence of occluder prolapse,malignant arrhythmia,or intensed valve regurgitation was seen on a median follow-up of 18 months(range,6 to 36 months).Conclusions:Based on our experience,ADO II showed good efficacy in the early and middle stages of pediatric pmVSD closures.