期刊文献+
共找到93篇文章
< 1 2 5 >
每页显示 20 50 100
Evaluation of Noise Levels in Different Industrial Sectors within the Gaza Strip: A Pilot Study
1
作者 Abed Schokry 《材料科学与工程(中英文A版)》 2015年第5期202-208,共7页
关键词 工业部门 噪音 地带 加沙 噪声暴露 试验 评价
下载PDF
Assessment of Indoor and Outdoor Noise Pollution at a University Hospital Based on Acoustic Measurements and Noise Mapping 被引量:1
2
作者 Paulo Henrique Trombetta Zannin Fernanda Ferraz 《Open Journal of Acoustics》 2016年第4期71-85,共15页
This paper describes an analysis of the sound pressure levels at the exterior fa&ccedil;ade and inside the Hospital de Clínicas of the Federal University of Paraná. Measurements were taken at a total of ... This paper describes an analysis of the sound pressure levels at the exterior fa&ccedil;ade and inside the Hospital de Clínicas of the Federal University of Paraná. Measurements were taken at a total of 45 points, 24 at the exterior facade and 21 points inside the hospital on all the floors of the main building and in the maternity building. These 45 measurements were used to calculate the acoustic map of the hospital, which is located on General Carneiro Street, in the city of Curitiba, state of Paraná, Brazil. A comparison of the measured outdoor sound pressure levels against those established by Curitiba Municipal Law No. 10625 revealed that they all exceeded the daytime limit of 55 dB(A) permitted for areas around hospitals. The indoor sound pressure measurements and the noise levels for acoustic comfort established by the Brazilian technical standard ABNT NBR 10152 were compared, indicating that all the measured points, including those in the neonatal intensive care unit, exceeded the established limit of 35 dB(A) to 45 dB(A). 展开更多
关键词 noise pollution University Hospital of the Federal University of Paraná Sound Measurements Sound Pressure levels noise Mapping
下载PDF
Assessment of Noise Pollution along Two Main Avenues in Curitiba, Brazil
3
作者 Paulo Henrique Trombetta Zannin Felipe do Valle Eriberto Oliveira do Nascimento 《Open Journal of Acoustics》 2019年第2期26-38,共13页
In this study, noise pollution assessments were performed along Marechal Deodoro Avenue and Batel Avenue, which are two major thoroughfares in the city of Curitiba, Brazil. Eleven points were evaluated at Batel Avenue... In this study, noise pollution assessments were performed along Marechal Deodoro Avenue and Batel Avenue, which are two major thoroughfares in the city of Curitiba, Brazil. Eleven points were evaluated at Batel Avenue and 16 points at Marechal Deodoro Avenue. The results of the noise level measurements and the calculation of noise maps indicated that both thoroughfares are acoustically polluted. The simulated and measured noise levels, in the 27 evaluated points, exceed the limits established by law 10,625 of the city of Curitiba, which establishes acceptable levels for the comfort of the population in the external environment. With regard to the traffic composition in the areas under study, the vehicle flow was found to consist mostly of light vehicles, representing 88% of the total flow along Batel Avenue and 85% on Marshal Deodoro Street. Based on the noise maps and measured noise levels, it was found that the entire length of Marshal Deodoro Avenue and Batel Avenue are strongly affected by street noise, which is readily explained by the constant traffic, high vehicle flow (number of vehicles/hour) and high vehicle speed at some points of these thoroughfares. 展开更多
关键词 noise pollution noise Mapping SOUND Pressure levelS noise Measurements Urban noise
下载PDF
A Survey of Noise Pollution in Ado-Ekiti Metropolis Using Mobile Phone
4
作者 Shadrach Tunde Akinkuade Kolawole Peter Fasae 《Natural Science》 2015年第10期475-482,共8页
Noise is considered as the most pervasive pollutant, it constitutes the most disturbing among the city pollutants and is a serious urban crisis in Ado Ekiti metropolis. Noise pollution was monitored at five different ... Noise is considered as the most pervasive pollutant, it constitutes the most disturbing among the city pollutants and is a serious urban crisis in Ado Ekiti metropolis. Noise pollution was monitored at five different locations in Ado-Ekiti, the capital town of Ekiti State of Nigeria. The study was done using a Virtual Instrument;a Sound Pressure Level mobile application installed on a mobile phone. The equivalent noise level using A-weighting was taken every fifteen minutes in each location between 6:00 am and 9:00 pm and the LAeq,T of each location was calculated. Maximum LAeq,6h of 105.40 dB was obtained in marketplace between 6:00 am and 12:00 pm while the minimum value of LAeq,6h obtained for a residential area in the same period is 69.51 dBA. The residents are exposed to average noise levels of 75 - 98 dB (A) or more every day which is higher than the recommended value of 60 dBA by WHO. This is very dangerous to the health of the people in these areas, and the results obtained in this study are useful as reference and guideline for future regulations on noise limit to be implemented for urban areas in Nigeria. 展开更多
关键词 noise pollution SOUND Pressure A-Weighting EQUIVALENT noise level
下载PDF
Analysis of Road Traffic Noise Pollution around a University in Binzhou
5
作者 Wang Yucheng Ma Kaizhen +3 位作者 Rong Kun Yang Qian Li Xueping Zhang Zaiwang 《Meteorological and Environmental Research》 CAS 2018年第3期52-53,59,共3页
The number of automobiles in the urban area of Binzhou City continues to increase,and traffic noise pollution is increasingly serious. In this study,noise pollution on Huanghe 5 Road near the south gate of Binzhou Uni... The number of automobiles in the urban area of Binzhou City continues to increase,and traffic noise pollution is increasingly serious. In this study,noise pollution on Huanghe 5 Road near the south gate of Binzhou University was monitored. The results showed that the road noise pollution on Huanghe 5 Road was relatively serious on the whole,especially in the peak periods of traffic flow in the morning and afternoon,because the increase in the number of pedestrians brought inconvenience to traffic,thereby resulting in an increase in car whistle. 展开更多
关键词 noise pollution Equivalent continuous A-weighted sound pressure level Road noise environment
下载PDF
Effects of geometric design of forest road and roadside vegetation on traffic noise reduction 被引量:1
6
作者 Seyed Ata Ollah Hosseini Seyran Zandi +1 位作者 Asghar Fallah Mehran Nasiri 《Journal of Forestry Research》 SCIE CAS CSCD 2016年第2期463-468,共6页
Geometric design of forest roads and design of their landscapes can reduce noise pollution and its harmful effects on human health. We investigated the effects of technical and biological parameters such as geometric ... Geometric design of forest roads and design of their landscapes can reduce noise pollution and its harmful effects on human health. We investigated the effects of technical and biological parameters such as geometric road design and various roadside tree stands on reducing noise pollution according to the tree density and distance from roadway in Darabkola Forests, Sari, Iran. We recorded the noise generated by a car (Land Rover) relative to changes in longitudinal slope, horizontal curve radius and type of road pavement. We also measured noise levels according to roadside tree density and stand type (coniferous and hardwood) in 40 rectangular plots of three widths (25, 100 and 300 m) and 50 m length that were randomly demar- cated along forest roads. The changes in noise level were recorded using a decibel meter with an accuracy of q-1.5 dB and resolution of 0.1 dB. Noise levels were higher alongside unpaved roads than alongside paved roads. There was an inverse relationship between the measured noise level and horizontal curve radius. The rate of noise level on horizontal curve with a radius less than 30, 30-45 m and more than 45 m were 64.8, 70.8 and 75.9 dB, respectively. The noise level increased with the increasing longitudinal slope of the road. There was a significant difference between the noise level on slopes less than 3 % (67 dB) and 3-8 % (71.2 dB) in comparison with slopes greater than 8 % (77.8 dB), (p 〈 0.05). Pinus brutia L. reduced the noise level more (about 6 dB) in stands of 1/3 density of mixed hardwoods within 25 m from middle of the road. Careful design of geometric properties of forest roads as well as planting coniferous trees with hardwoods is a suitable solution for reducing noise pollution. 展开更多
关键词 Forest road noise pollution noise level VEGETATION DISTRIBUTION
下载PDF
Traffic Noise Pollution: Spectra Characteristics and Windows Sound Insulation in Laboratory and Field Measurements 被引量:2
7
作者 C. Buratti E. Moretti 《Journal of Environmental Science and Engineering》 2010年第12期28-36,共9页
The traffic spectra influence on indoor noise through windows is evaluated with laboratory and field measurements. Different traffic noise spectra were registered and reproduced, simulating the outdoor traffic conditi... The traffic spectra influence on indoor noise through windows is evaluated with laboratory and field measurements. Different traffic noise spectra were registered and reproduced, simulating the outdoor traffic conditions through different windows. Spectrum adaptation terms for the recorded spectra were different from the ones obtained from the Standards, showing that Normative gives a safe evaluation of the Weighted Sound Insulation Index. In field measurements, the level abatements calculated from the Facade Acoustic Insulation Index corrected with the adaptation terms shows that the ones from the Standard do not give a good approximation, while if the level abatements is calculated using the adaptation terms from the registered spectra, a more reliable approximation is achieved. Furthermore, comparing the level abatements for two windows having both Rw equal to 41 dB, very different values were obtained at different frequencies; therefore to characterize acoustic performances of windows, sound insulation curves are also needed. The correlation between the mean difference between adaptation terms calculated from the standard and the one between abatements obtained with pink noise and the ones obtained with the registered spectra is good, but different for road traffic and trains. In both, the difference diminishes when the difference between the abatements increases. 展开更多
关键词 Traffic noise pollution traffic noise spectra spectrum adaptation terms level abatements
下载PDF
高位收水冷却塔噪声预测方法优化及噪声治理措施探讨
8
作者 张翔 陈兴旺 +2 位作者 史玉柱 房小健 王奇 《环境影响评价》 2024年第1期57-61,共5页
对湖北省某660 MW燃煤发电厂高位收水冷却塔进行了现场测试,根据测试结果对高位收水冷却塔噪声预测模型进行了优化和验证,并对高位收水冷却塔的噪声治理措施进行了探讨。结果表明,采用发声部位水平面声源优化模型计算得到的高位收水冷... 对湖北省某660 MW燃煤发电厂高位收水冷却塔进行了现场测试,根据测试结果对高位收水冷却塔噪声预测模型进行了优化和验证,并对高位收水冷却塔的噪声治理措施进行了探讨。结果表明,采用发声部位水平面声源优化模型计算得到的高位收水冷却塔噪声衰减规律与实测结果更加接近;虽然高位收水冷却塔附近地面噪声源强实测声级较常规冷却塔低约8 dB(A),但总体声功率级的改善效果并不能达到8 dB(A)的水平;同时,由于高位收水冷却塔声源位置较高,对围墙外某些特殊点位,高位收水冷却塔的噪声影响可能反而会略高于常规冷却塔;消声导流片及吸隔声屏障在应用于高位收水冷却塔降噪时需根据声源实际情况进行模型验证优化,而声源降噪措施可从改善水滴对收水斜板的冲击以及收水斜板本身振动噪声方面进一步研究。 展开更多
关键词 高位收水冷却塔 噪声影响 噪声预测 噪声治理
下载PDF
某矿区采选扩建工程对地下水的影响评价分析
9
作者 祝融峰 《绿色矿冶》 2024年第5期87-91,107,共6页
本文以某矿区采选扩建工程为研究对象,在详细介绍该扩建工程建设规模、采选工艺、供排水方案基础上,通过前期地质勘查、地形地貌调查、室内试验等方式,对区域工程地质条件、水文地质条件以及地下水存储情况进行了分析。采用预测模型概... 本文以某矿区采选扩建工程为研究对象,在详细介绍该扩建工程建设规模、采选工艺、供排水方案基础上,通过前期地质勘查、地形地貌调查、室内试验等方式,对区域工程地质条件、水文地质条件以及地下水存储情况进行了分析。采用预测模型概化手段,预测该扩建工程建设对地下水水质和地下水水位产生的影响,提出了源头控制、分区防控、强化监测等地下水环境保护措施。 展开更多
关键词 地下水污染 预测模型 水质影响预测 水位影响预测
下载PDF
PREDICTION AND EVALUATION OF POLLUTION OF URBAN TRAFFIC NOISE IN CHINA
10
作者 方丹群 刘克 陈潜 《Science China Mathematics》 SCIE 1989年第1期93-100,共8页
The medium/long term prediction of urban traffic noise and evaluation of noisepollution in "macroscopic" way using computer are new research work in China. Inthis paper, some investigations, including the me... The medium/long term prediction of urban traffic noise and evaluation of noisepollution in "macroscopic" way using computer are new research work in China. Inthis paper, some investigations, including the methods of predicting and evaluatingurban traffic pollution, have been repotted. Models for vehicles’ flow and propagationof noise in urban areas have been set up. Finally, a set of computer programs forthese purposes is given. Models and computer program have been tested in more than70 cities of China. It is proved that they can be used in medium/long term predictionof urban traffic noise pollution in China, and they are also of great values in evalu-ating the extent of urban traffic noise pollution. 展开更多
关键词 TRAFFIC noise predictION EVALUATION noise pollution.
原文传递
Urban Noise in a Metropolitan Towns
11
作者 Lakavath Ravinder Mesfin Getahun Belachew 《Open Journal of Acoustics》 2014年第4期163-176,共14页
This study is aimed at bringing out the salient aspects of urban noise and its study and control aspects, at different location of a metropolitans town. Field measurements at different points of times a day have also ... This study is aimed at bringing out the salient aspects of urban noise and its study and control aspects, at different location of a metropolitans town. Field measurements at different points of times a day have also been recorded at a number of high-traffic-intensity locations on main roads of towns. The data obtained are analyzed using SPSS package for calculation through ANOVA technique and the findings of these studies have been recorded. The variation of SPL considering the time of the day has been studied and illustrated through graphical plots. It shows that the peak early morning max sound pressure levels observed over the recommended limiting value. In some places, the low frequency noise predominates in the early morning hours, noise levels are significant among and within the 15 groups. The variation of sound pressure (Maximum, Minimum and L equivalent readings) levels as shown in the graphical plots, the Maximum and L equivalent levels exceeded the recommended noise level. Important conclusions of this work have been drawn subsequently. 展开更多
关键词 noise pollution noise Effects noise Control SPSS PACKAGE ANOVA Technique SOUND Pressure level Decibel-Sound SOUND When A-Weighted
下载PDF
化工装置调节阀的噪声预测 被引量:1
12
作者 刘珊 《石油化工自动化》 CAS 2023年第5期15-20,34,共7页
当调节阀噪声过高时往往预示着阀门内存在非正常的流体工况,同时也会损害现场操作人员的人身健康。根据国内外相关规范以及一些相关文献,介绍了阀门噪声控制要求和定义,以及不可压缩流体、可压缩流体的阀门噪声计算方法和注意事项,并对... 当调节阀噪声过高时往往预示着阀门内存在非正常的流体工况,同时也会损害现场操作人员的人身健康。根据国内外相关规范以及一些相关文献,介绍了阀门噪声控制要求和定义,以及不可压缩流体、可压缩流体的阀门噪声计算方法和注意事项,并对调节阀的噪声产生过程与预测方法进行探讨。通过计算阀门噪声,可有效预判阀门气蚀,有助于降低气蚀风险或气相阻塞流工况。 展开更多
关键词 噪声预测 调节阀 流体参数 声压级
下载PDF
新乡市城市声环境质量灰色预测
13
作者 沙涛 李爱琴 《干旱环境监测》 2023年第1期22-27,共6页
本文对“十三五”期间新乡市城市环境噪声污染现状及趋势进行分析。并采用灰色预测GM(1,1)模型预测新乡市未来5 a城市噪声环境质量,灰色关联分析得出有效治理对策。结果表明:经模型预测新乡市2021—2025年城市区域噪声、功能区噪声(昼... 本文对“十三五”期间新乡市城市环境噪声污染现状及趋势进行分析。并采用灰色预测GM(1,1)模型预测新乡市未来5 a城市噪声环境质量,灰色关联分析得出有效治理对策。结果表明:经模型预测新乡市2021—2025年城市区域噪声、功能区噪声(昼间、夜间)等效声级呈小幅下降趋势,道路交通噪声等效声级呈上升趋势,级别由“较好”变为“一般”,污染防控方面压力较大,需加大监管力度。通过交通噪声影响因子关联性分析得出应从人口增加、机动车数量、城镇化扩张等方面制定有效防治措施。 展开更多
关键词 新乡市 噪声污染 灰色理论 预测 防治对策
下载PDF
春节期间燃放烟花爆竹对城市声环境的影响
14
作者 谢文波 欧文雅 +2 位作者 张大伟 翟继武 魏嘉庚 《黑龙江环境通报》 2023年第5期57-59,共3页
2020年噪声污染位列中国城市环境四大公害第二位。通过比较2021年和2022年春节期间赤峰市中心城市功能区声环境昼间等效声级和夜间等效声级达标率,并对2年同期昼间等效声级、夜间等效声级进行等级划分,判别春节期间燃放烟花爆竹的社会... 2020年噪声污染位列中国城市环境四大公害第二位。通过比较2021年和2022年春节期间赤峰市中心城市功能区声环境昼间等效声级和夜间等效声级达标率,并对2年同期昼间等效声级、夜间等效声级进行等级划分,判别春节期间燃放烟花爆竹的社会活动对赤峰市中心城市4个类别功能区的影响。结果表明,禁止燃放烟花可有效提高赤峰市中心城市功能区声环境的达标率,尤其对1类区和2类区影响明显,同时验证新的功能区声环境监测点位布设合理。 展开更多
关键词 声环境 噪声污染 等效声级 影响程度 达标率
下载PDF
特高压交流变电站噪声测量与分析 被引量:69
15
作者 周兵 裴春明 +1 位作者 倪园 张建功 《高电压技术》 EI CAS CSCD 北大核心 2013年第6期1447-1453,共7页
为掌握特高压交流变电站厂界噪声水平,测量了站内变压器与电抗器的噪声水平及其频谱特性、衰减特性以及与功率负荷之间的关系。测量试验在正常运行及大负荷调试期间的特高压试验示范工程变电站进行,并对测量结果进行了进一步分析。结果... 为掌握特高压交流变电站厂界噪声水平,测量了站内变压器与电抗器的噪声水平及其频谱特性、衰减特性以及与功率负荷之间的关系。测量试验在正常运行及大负荷调试期间的特高压试验示范工程变电站进行,并对测量结果进行了进一步分析。结果表明,变压器噪声以中低频噪声为主,受冷却风扇影响较大,且与功率负荷近似正相关。电抗器噪声能量集中在中心频率为100Hz的1/3倍频带上,与功率负荷关系较小。变压器和电抗器噪声随距离增加而较慢衰减,因此变压器和电抗器应远离声环境敏感区域。另外,通过该研究,确定了正常负荷下特高压变压器和电抗器的A计权声功率级分别约为103dB和97dB,并获得了声源的1/3倍频带声功率级参数,为变电站噪声预测评价提供了基础数据。 展开更多
关键词 变压器 电抗器 频率 噪声预测 声压级 特高压
下载PDF
高速公路声屏障优化设计的模拟计算研究 被引量:7
16
作者 翟云波 王志瑞 +1 位作者 马迎春 叶颖 《湖南大学学报(自然科学版)》 EI CAS CSCD 北大核心 2013年第9期98-102,共5页
选取一种声屏障作为研究对象,根据拟建高速公路周边噪声敏感点的分布特点,构建现实的模拟场景,利用Cadna/A噪声模拟软件建立声屏障降噪预测模型,对该声屏障设置参数进行了优化研究.研究结果发现:在现实的模拟场景中,当右侧声屏障长440m... 选取一种声屏障作为研究对象,根据拟建高速公路周边噪声敏感点的分布特点,构建现实的模拟场景,利用Cadna/A噪声模拟软件建立声屏障降噪预测模型,对该声屏障设置参数进行了优化研究.研究结果发现:在现实的模拟场景中,当右侧声屏障长440m高3.6m,左侧声屏障长400m高4.4m时,该声屏障不仅使所有敏感点达标,且实现了建设成本的最小化. 展开更多
关键词 模拟 预测 优化 噪声污染
下载PDF
机场噪声预测与计算 被引量:7
17
作者 赵仁兴 沈洪艳 +1 位作者 刘劲松 闫宁 《河北工业科技》 CAS 2000年第1期24-27,共4页
采用计权等效连续感觉噪声级LWECPN作为机场噪声评价参数,具体结合机场及周围地区的地形、航班、机种及飞机起降航迹等计算并绘出机场周围地区的等声级噪声暴露图。
关键词 机场 噪声等值线图 预测 噪声 计算
下载PDF
风电机组噪声预测 被引量:6
18
作者 翟国庆 徐婧 +1 位作者 郑玥 李争光 《中国环境科学》 EI CAS CSCD 北大核心 2012年第5期927-932,共6页
在已有后缘为钝形双叶片风电机组噪声预测模型基础上,结合我国风力发电机组叶片形状及其辐射噪声的频谱特性等,对预测模型进行了修正.通过对3台不同型号风电机组13个测点噪声测量值和预测值对比验证表明,修正后模型能较好地反映风电机... 在已有后缘为钝形双叶片风电机组噪声预测模型基础上,结合我国风力发电机组叶片形状及其辐射噪声的频谱特性等,对预测模型进行了修正.通过对3台不同型号风电机组13个测点噪声测量值和预测值对比验证表明,修正后模型能较好地反映风电机组噪声的衰减规律.在预测点与风轮中心距离大于1.5倍风轮直径时,修正后模型预测值与实测值差值在±2.5dB(A)范围内.利用修正后预测模型计算确定的风电机组噪声声功率级及指向性指数,将其代入考虑指向性的点声源模型,可用于简化预测与风轮中心距离大于3倍风轮直径处的噪声. 展开更多
关键词 噪声 风电机组 预测模型 声功率级
下载PDF
基于GIS的铁路噪声预测与评价方法 被引量:4
19
作者 马民涛 任杰 +2 位作者 赵永梅 缑凯丛 高磊 《北京工业大学学报》 EI CAS CSCD 北大核心 2006年第10期944-947,共4页
为提高铁路噪声的预测与评价水平,提出了基于GIS的铁路噪声预测与评价方法.将GIS与铁路噪声预测模型进行集成,通过选取预测铁路,输入相关参数,调用预测函数和绘图函数进行噪声计算和绘制等声级线,可以根据噪声值表和等声级线分布图进... 为提高铁路噪声的预测与评价水平,提出了基于GIS的铁路噪声预测与评价方法.将GIS与铁路噪声预测模型进行集成,通过选取预测铁路,输入相关参数,调用预测函数和绘图函数进行噪声计算和绘制等声级线,可以根据噪声值表和等声级线分布图进行铁路噪声的影响分析并制订相应对策. 展开更多
关键词 地理信息系统 预测 评价 铁路噪声污染
下载PDF
连铸结晶器液位预测控制 被引量:7
20
作者 郭戈 王伟 柴天佑 《控制理论与应用》 EI CAS CSCD 北大核心 2001年第5期714-716,721,共4页
提出一种能克服有色噪声扰动的广义预测控制方法 ,并将其用于结晶器液位控制中 ,结果表明液位偏差较小 ,系统鲁棒性大大改善 .
关键词 结晶器液位 广义预测控制 鲁棒性 连铸生产过程 PID控制
下载PDF
上一页 1 2 5 下一页 到第
使用帮助 返回顶部