Background: Fractures of humeral shaft in adults are common injuries. Humeral shafts non-union either from late presentation after initial treatment by traditional bone setters or failed non-operative orthodox care is...Background: Fractures of humeral shaft in adults are common injuries. Humeral shafts non-union either from late presentation after initial treatment by traditional bone setters or failed non-operative orthodox care is a major problem in this part of the world. This non-union is a major treatment challenge with increased cost of care and morbidity in this part of the world. Humeral shaft non-union can be treated with locked intra-medullary nailing (LIMN) or dynamic compression plating (DCP). Study on comparison of these methods of fixation in this part of the world is scarce in literature search, hence the reason for this study. Objective: The objectives of this study are: (1) to compare early clinical outcome following fixation of humeral shaft fracture nonunion with DCP versus LIMN;(2) to compare the time of radiologic fracture union of DCP with LIMN;(3) to compare complications following fixation of humeral shaft fracture nonunion with DCP versus LIMN. Patients and Methods: This was a randomized control study done for 2 years in which fifty adult patients with humeral shaft non-union were recruited. The patients were grouped into 2 (P = DCP & N = LIMN). Forty five of the patients completed the follow up periods of the study and then analyzed. The P group had ORIF with DCP while the N group had ORIF with LIMN. Both groups had grafting with cancellous bones. Each patient was followed up for a period of 6 months at the time which radiographic union is expected. Any patient without clinical and/or radiographic evidence of union after six months of surgery was diagnosed as having recurrent non-union. The data generated was analyzed using SPSS Version 23. The results were presented in charts and tables. The paired t-test was used while considering p value Result: Forty five patients completed follow up. There was a male preponderance (4:1), right humerus predominated (3:2). Motor vehicular accidents were the commonest cause of the fractures (62%). Most non-union fractures occurred at the level of the middle 3<sup>rd</sup> of the humeral shaft (60%). Failed TBS treatment was the commonest indication for the osteosynthesis (71%). More patients had plating (53%) compared to 47% who had LIMN. Most patients (93.4%) had union between 3 to 6 months irrespective of fixation type with no significant statistical difference between the union rate of DCP and LIMN (p value 0.06) with similar functional outcome and complication rates irrespective of the type of fixation. Conclusion: This study showed that the success rates in term of fracture union, outcome functional grades and complication rates were not directly dependent on the types of the fixation: plating or locked intra-medullary nailing.展开更多
Post cam mechanism of Posterior Stabilized (PS) knee prostheses is useful to realize intrinsic stability for cases with severe degeneration. However, some retrieval studies report severe failure of the polyethylene ti...Post cam mechanism of Posterior Stabilized (PS) knee prostheses is useful to realize intrinsic stability for cases with severe degeneration. However, some retrieval studies report severe failure of the polyethylene tibial post. We thought that severe failures were caused by high loads during daily activities. In the current study, we performed a compression test and a finite element analysis of the mechanical forces produced in the tibial post in posterior-stabilized knee prostheses in order to develop a specification for the tibial posts found in the polyethylene inserts of PS knee prostheses. Anterior tibial post impingement and posterior tibial post impingement were simulated. The surface pressure values detected in the compression test were consistent with those obtained in the FE analysis. Of the three designs, the lowest von Mises stress values were generated inside the round tibial post;therefore, tibial posts should be round. The risk of tibial post failure was low when 500 or 1000 N was loaded onto the knee joint. It was suggested that tibial post failure occurs when the shear strain at the base of the tibial post exceeds 0.1.展开更多
In proximal humeral fracture except AO classification 11A1, fixations with a locking plate and nails are recommended. We performed mechanical tests to investigate whether retrograde intramedullary nailing has fixation...In proximal humeral fracture except AO classification 11A1, fixations with a locking plate and nails are recommended. We performed mechanical tests to investigate whether retrograde intramedullary nailing has fixation stability comparable to those of anterograde intramedullary nailing and locking plate which achieve clinically favorable outcomes. In retrograde intramedullary nailing, a nail entry point is made in the diaphysis, for which reduction of stiffness of the humerus is of concern. Thus, we investigated the influence of a nail entry point made in the diaphysis on humeral strength. Retrograde intramedullary nailing had fixation stability against bending and a force loaded in the rotation direction comparable to those of anterograde intramedullary nail and locking plate. Displacement by the main external force loaded on the humerus, compressive load, was less than half in the bone fixed by retrograde intramedullary nailing compared with that in the bone fixed with a locking plate, showing favorable fixation stability. It was clarified that stiffness of the humerus against rotation and a load in the compression direction is not reduced by a nail entry point made by retrograde intramedullary nailing.展开更多
Background Although the locking plate has become popular for treating displaced proximal humeral fractures in recent years, the complications of this method are still underestimated. We tried to evaluate the factors t...Background Although the locking plate has become popular for treating displaced proximal humeral fractures in recent years, the complications of this method are still underestimated. We tried to evaluate the factors that have an influence on the complications experienced after proximal humeral fractures fixed by locking plates and compare the results from patients having complications with those having no complications. Methods From September 2004 to September 2007, 92 out of 111 displaced proximal humeral fractures treated by open reduction and internal fixation with a locking plate were available for follow-up, with an average time of 15.2 months (12-36 months). The range of motion, Visual Analog Score (VAS) for pain, American Shoulder and Elbow Surgeons' Form (ASES), Constant-Murley, University of California-Los Angles scoring system (UCLA) score, and Simple Shoulder Test (SST) for function evaluation was all recorded at the latest follow-up. The results from patients with complications were evaluated according to the indices listed above and compared with those patients without any complications. Results There were 17 patients with complications, an 18.5% complication rate. Among them, the forward flexion, external rotation and internal rotation were 139.1°±24.3°, 24.1°±19.6°, and up to T10 level on average. The mean VAS score was 1.0±1.1, the ASES score was 82.9±13.8, the Constant 82.1±11.8, the UCLA 28.5±4.1 and the mean SST 9.5 on average. There was no significant difference of complication rate among different age, sex, and injured side, fresh or delayed fracture, combined with other injury or not groups. Compared with the group without complications, patients with complications showed significantly less external rotation and lower Constant-Murley and UCLA functional scores (P 〈0.05). A significant difference in results was seen between patients with complications and those without complications. Conclusion The indication control and appropriate surgical technique were important while performing the locking plate fixation for proximal humeral fractures.展开更多
BACKGROUND Ipsilateral femoral neck and intertrochanteric fractures in young patients are extremely rare,and there is no reference for fracture classification and treatment options.CASE SUMMARY We report a 27-year-old...BACKGROUND Ipsilateral femoral neck and intertrochanteric fractures in young patients are extremely rare,and there is no reference for fracture classification and treatment options.CASE SUMMARY We report a 27-year-old male patient who sustained ipsilateral femoral neck and intertrochanteric fractures and was treated with a proximal femoral locking compression plate(PFLCP).The literature on these fractures was also reviewed.At the last follow-up three years after surgery,the patient had no obvious pain in the hip,and the range of motion in the hip joint was slightly limited,but met the normal life and work needs.There were no complications such as necrosis of the femoral head.CONCLUSION The PFLCP can be used to treat these complex proximal femoral fractures,and selection should be based on the patient's specific fractures.展开更多
文摘Background: Fractures of humeral shaft in adults are common injuries. Humeral shafts non-union either from late presentation after initial treatment by traditional bone setters or failed non-operative orthodox care is a major problem in this part of the world. This non-union is a major treatment challenge with increased cost of care and morbidity in this part of the world. Humeral shaft non-union can be treated with locked intra-medullary nailing (LIMN) or dynamic compression plating (DCP). Study on comparison of these methods of fixation in this part of the world is scarce in literature search, hence the reason for this study. Objective: The objectives of this study are: (1) to compare early clinical outcome following fixation of humeral shaft fracture nonunion with DCP versus LIMN;(2) to compare the time of radiologic fracture union of DCP with LIMN;(3) to compare complications following fixation of humeral shaft fracture nonunion with DCP versus LIMN. Patients and Methods: This was a randomized control study done for 2 years in which fifty adult patients with humeral shaft non-union were recruited. The patients were grouped into 2 (P = DCP & N = LIMN). Forty five of the patients completed the follow up periods of the study and then analyzed. The P group had ORIF with DCP while the N group had ORIF with LIMN. Both groups had grafting with cancellous bones. Each patient was followed up for a period of 6 months at the time which radiographic union is expected. Any patient without clinical and/or radiographic evidence of union after six months of surgery was diagnosed as having recurrent non-union. The data generated was analyzed using SPSS Version 23. The results were presented in charts and tables. The paired t-test was used while considering p value Result: Forty five patients completed follow up. There was a male preponderance (4:1), right humerus predominated (3:2). Motor vehicular accidents were the commonest cause of the fractures (62%). Most non-union fractures occurred at the level of the middle 3<sup>rd</sup> of the humeral shaft (60%). Failed TBS treatment was the commonest indication for the osteosynthesis (71%). More patients had plating (53%) compared to 47% who had LIMN. Most patients (93.4%) had union between 3 to 6 months irrespective of fixation type with no significant statistical difference between the union rate of DCP and LIMN (p value 0.06) with similar functional outcome and complication rates irrespective of the type of fixation. Conclusion: This study showed that the success rates in term of fracture union, outcome functional grades and complication rates were not directly dependent on the types of the fixation: plating or locked intra-medullary nailing.
文摘Post cam mechanism of Posterior Stabilized (PS) knee prostheses is useful to realize intrinsic stability for cases with severe degeneration. However, some retrieval studies report severe failure of the polyethylene tibial post. We thought that severe failures were caused by high loads during daily activities. In the current study, we performed a compression test and a finite element analysis of the mechanical forces produced in the tibial post in posterior-stabilized knee prostheses in order to develop a specification for the tibial posts found in the polyethylene inserts of PS knee prostheses. Anterior tibial post impingement and posterior tibial post impingement were simulated. The surface pressure values detected in the compression test were consistent with those obtained in the FE analysis. Of the three designs, the lowest von Mises stress values were generated inside the round tibial post;therefore, tibial posts should be round. The risk of tibial post failure was low when 500 or 1000 N was loaded onto the knee joint. It was suggested that tibial post failure occurs when the shear strain at the base of the tibial post exceeds 0.1.
文摘In proximal humeral fracture except AO classification 11A1, fixations with a locking plate and nails are recommended. We performed mechanical tests to investigate whether retrograde intramedullary nailing has fixation stability comparable to those of anterograde intramedullary nailing and locking plate which achieve clinically favorable outcomes. In retrograde intramedullary nailing, a nail entry point is made in the diaphysis, for which reduction of stiffness of the humerus is of concern. Thus, we investigated the influence of a nail entry point made in the diaphysis on humeral strength. Retrograde intramedullary nailing had fixation stability against bending and a force loaded in the rotation direction comparable to those of anterograde intramedullary nail and locking plate. Displacement by the main external force loaded on the humerus, compressive load, was less than half in the bone fixed by retrograde intramedullary nailing compared with that in the bone fixed with a locking plate, showing favorable fixation stability. It was clarified that stiffness of the humerus against rotation and a load in the compression direction is not reduced by a nail entry point made by retrograde intramedullary nailing.
文摘Background Although the locking plate has become popular for treating displaced proximal humeral fractures in recent years, the complications of this method are still underestimated. We tried to evaluate the factors that have an influence on the complications experienced after proximal humeral fractures fixed by locking plates and compare the results from patients having complications with those having no complications. Methods From September 2004 to September 2007, 92 out of 111 displaced proximal humeral fractures treated by open reduction and internal fixation with a locking plate were available for follow-up, with an average time of 15.2 months (12-36 months). The range of motion, Visual Analog Score (VAS) for pain, American Shoulder and Elbow Surgeons' Form (ASES), Constant-Murley, University of California-Los Angles scoring system (UCLA) score, and Simple Shoulder Test (SST) for function evaluation was all recorded at the latest follow-up. The results from patients with complications were evaluated according to the indices listed above and compared with those patients without any complications. Results There were 17 patients with complications, an 18.5% complication rate. Among them, the forward flexion, external rotation and internal rotation were 139.1°±24.3°, 24.1°±19.6°, and up to T10 level on average. The mean VAS score was 1.0±1.1, the ASES score was 82.9±13.8, the Constant 82.1±11.8, the UCLA 28.5±4.1 and the mean SST 9.5 on average. There was no significant difference of complication rate among different age, sex, and injured side, fresh or delayed fracture, combined with other injury or not groups. Compared with the group without complications, patients with complications showed significantly less external rotation and lower Constant-Murley and UCLA functional scores (P 〈0.05). A significant difference in results was seen between patients with complications and those without complications. Conclusion The indication control and appropriate surgical technique were important while performing the locking plate fixation for proximal humeral fractures.
文摘BACKGROUND Ipsilateral femoral neck and intertrochanteric fractures in young patients are extremely rare,and there is no reference for fracture classification and treatment options.CASE SUMMARY We report a 27-year-old male patient who sustained ipsilateral femoral neck and intertrochanteric fractures and was treated with a proximal femoral locking compression plate(PFLCP).The literature on these fractures was also reviewed.At the last follow-up three years after surgery,the patient had no obvious pain in the hip,and the range of motion in the hip joint was slightly limited,but met the normal life and work needs.There were no complications such as necrosis of the femoral head.CONCLUSION The PFLCP can be used to treat these complex proximal femoral fractures,and selection should be based on the patient's specific fractures.