期刊文献+
共找到9篇文章
< 1 >
每页显示 20 50 100
Experimental Study on the Thermal Performances of a Tube-Type Indirect Evaporative Cooler
1
作者 Tiezhu Sun Huan Sun +2 位作者 Tingzheng Tang Yongcheng Yan Peixuan Li 《Fluid Dynamics & Materials Processing》 EI 2023年第10期2519-2531,共13页
The so-called indirect evaporative cooling technology is widely used in air conditioning applications.The thermal characterization of tube-type indirect evaporative coolers,however,still presents challenges which need... The so-called indirect evaporative cooling technology is widely used in air conditioning applications.The thermal characterization of tube-type indirect evaporative coolers,however,still presents challenges which need to be addressed to make this technology more reliable and easy to implement.This experimental study deals with the performances of a tube-type indirect evaporative cooler based on an aluminum tube with a 10 mm diameter.In particular,the required tests were carried out considering a range of dry-bulb temperatures between 16℃ and 18℃ and a temperature difference between the wet-bulb and dry-bulb temperature of 2℃∼4℃.The integrated convective heat transfer coefficient inside the tube in the drenching condition has been found to lie in the range between 36.10 and 437.4(W/(m^(2)⋅K)). 展开更多
关键词 Tubular indirect evaporative cooler integrated convection heat transfer coefficient evaporative cooling thermal engineering calculation energy saving
下载PDF
The Application of Thermomechanical Dynamics (TMD) to Thermoelectric Energy Generation by Employing a Low Temperature Stirling Engine
2
作者 Hiroshi Uechi Lisa Uechi Schun T. Uechi 《Journal of Applied Mathematics and Physics》 2024年第9期3185-3207,共23页
A thermoelectric generation Stirling engine (TEG-Stirling engine) is discussed by employing a low temperature Stirling engine and the dissipative equation of motion derived from the method of thermomechanical dynamics... A thermoelectric generation Stirling engine (TEG-Stirling engine) is discussed by employing a low temperature Stirling engine and the dissipative equation of motion derived from the method of thermomechanical dynamics (TMD). The results and mechanism of axial flux electromagnetic induction (AF-EMI) are applied to a low temperature Stirling engine, resulting in a TEG-Stirling engine. The method of TMD produced thermodynamically consistent and time-dependent physical quantities for the first time, such as internal energy ℰ(t), thermodynamic work Wth(t), the total entropy (heat dissipation) Qd(t)and measure or temperature of a nonequilibrium state T˜(t). The TMD analysis produced a lightweight mechanical system of TEG-Stirling engine which derives electric power from waste heat of temperature (40˚CT100˚C) by a thermoelectric conversion method. An optimal low rotational speed about 30θ′(t)/(2π)60(rpm) is found, applicable to devices for sustainable, clean energy technologies. The stability of a thermal state and angular rotations of TEG-Stirling engine are specifically shown by employing properties of nonequilibrium temperature T˜(t), which is also applied to study optimal fuel-injection and combustion timings of heat engines. 展开更多
关键词 Thermoelectric Generation Stirling Engine (TEG-Stirling Engine) Thermomechanical Dynamics (TMD) Time-Dependent Nonequilibrium Temperature Stability of Heat engines in a thermal State Optimal Fuel-Injection and Combustion Timings
下载PDF
SIMULATION IN THERMAL DESIGN FOR ELECTRONIC CONTROL UNIT OF ELECTRONIC UNIT PUMP 被引量:1
3
作者 XU Quankui ZHU Keqing ZHUO Bin MAO Xiaojian WANG Junxi 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2008年第5期1-7,共7页
The high working junction temperature of power component is the most common reason of its failure. So the thermal design is of vital importance in electronic control unit (ECU) design. By means of circuit simulation... The high working junction temperature of power component is the most common reason of its failure. So the thermal design is of vital importance in electronic control unit (ECU) design. By means of circuit simulation, the thermal design of ECU for electronic unit pump (EUP) fuel system is applied. The power dissipation model of each power component in the ECU is created and simulated. According to the analyses of simulation results, the factors which affect the power dissipation of components are analyzed. Then the ways for reducing the power dissipation of power components are carried out. The power dissipation of power components at different engine state is calculated and analyzed. The maximal power dissipation of each power component in all possible engine state is also carried out based on these simulations. A cooling system is designed based on these studies. The tests show that the maximum total power dissipation of ECU drops from 43.2 W to 33.84 W after these simulations and optimizations. These applications of simulations in thermal design of ECU can greatly increase the quality of the design, save the design cost and shorten design time 展开更多
关键词 Diesel engine Electronic unit pump Electronic control unit Circuit simulation thermal design
下载PDF
Examination of the Thermal Cloaking Effectiveness with Layered Engineering Materials
4
作者 胡润 胡锦炎 +3 位作者 吴睿康 谢斌 余兴建 罗小兵 《Chinese Physics Letters》 SCIE CAS CSCD 2016年第4期72-75,共4页
The concentrically layered thermal cloaks with isotropic materials could realize the equivalent thermal cloaking effect with Pendry's cloak, while the effectiveness is scarcely investigated quantitatively. Here we ex... The concentrically layered thermal cloaks with isotropic materials could realize the equivalent thermal cloaking effect with Pendry's cloak, while the effectiveness is scarcely investigated quantitatively. Here we examine the cloaking effectiveness quantitatively by evaluating the standard deviation of the temperature difference between the simulated plane with the layered thermal cloak and Pendry's thermal cloak. The design rules for the isotropic materials in terms of thermal conductivity and layer thickness are presented. The present method could quan- titatively evaluate the cloaking effectiveness, and could open avenues for analyzing the cloaking effect, detecting the (anti-) cloaks, etc. 展开更多
关键词 of in on STD Examination of the thermal Cloaking Effectiveness with Layered Engineering Materials with
下载PDF
Novel Technology and Products: Fluidized Bed Incineration and Energy Recovery for Waste Disposal——Developed by the Institute for Thermal Power Engineering, Zhejiang University
5
《China's Foreign Trade》 1997年第7期34-35,共2页
The waste referred to includes solid waste and sludge. Solid waste is mainly from urban garbage and industrial waste. Sludge is from water treatment factories, paper mills, chemical factories, pharmaceutical factories... The waste referred to includes solid waste and sludge. Solid waste is mainly from urban garbage and industrial waste. Sludge is from water treatment factories, paper mills, chemical factories, pharmaceutical factories, rivers and lakes. The waste and sludge are very harmful to water organisms, human health and drinking water, and directly affect the environment. Sludge and waste also occupy large areas of land. There are several methods to treat waste and sludge, such as burial, chemical treatment and incineration. Incineration is more effective than the 展开更多
关键词 In Novel Technology and Products Zhejiang University Developed by the Institute for thermal Power Engineering Fluidized Bed Incineration and Energy Recovery for Waste Disposal
下载PDF
Country-level meteorological parameters for building energy efficiency in China 被引量:3
6
作者 LIU Yan WANG Shang-yu +2 位作者 CAO Qi-meng LU Mei YANG Liu 《Journal of Central South University》 SCIE EI CAS CSCD 2022年第7期2301-2316,共16页
Accurate basic data are necessary to support performance-based design for achieving carbon peak and carbon neutral targets in the building sector.Meteorological parameters are the prerequisites of building thermal eng... Accurate basic data are necessary to support performance-based design for achieving carbon peak and carbon neutral targets in the building sector.Meteorological parameters are the prerequisites of building thermal engineering design,heating ventilation and air conditioning design,and energy consumption simulations.Focusing on the key issues such as low spatial coverage and the lack of daily or higher time resolution data,daily and hourly models of the surface meteorological data and solar radiation were established and evaluated.Surface meteorological data and solar radiation data were generated for 1019 cities and towns in China from 1988 to 2017.The data were carefully compared,and the accuracy was proved to be high.All the meteorological parameters can be assessed in the building sector via a sharing platform.Then,country-level meteorological parameters were developed for energy-efficient building assessment in China,based on actual meteorological data in the present study.This set of meteorological parameters may facilitate engineering applications as well as allowing the updating and expansion of relevant building energy efficiency standards.The study was supported by the National Science and Technology Major Project of China during the 13th Five-Year Plan Period,named Fundamental parameters on building energy efficiency in China,comprising of 15 top-ranking universities and institutions in China. 展开更多
关键词 building energy efficiency building thermal engineering heating ventilation and air conditioning meteorological parameters solar radiation
下载PDF
Visualization of 3-D temperature distribution in a 300 MW twin-furnace coal-fired boiler 被引量:4
7
作者 YANG Chao ZHOU Huai-chun HUANG Zhi-feng 《Journal of China University of Mining and Technology》 EI 2008年第1期33-37,共5页
Until now, it has been difficult to obtain on-line three-dimensional (3-D) temperature distribution information which can reflect the overall combustion condition in the furnace of a coal-fired power plant boiler. A c... Until now, it has been difficult to obtain on-line three-dimensional (3-D) temperature distribution information which can reflect the overall combustion condition in the furnace of a coal-fired power plant boiler. A combustion monitoring system is introduced which can solve the problem efficiently. Through this system, the 3-D temperature distribution in a coal-fired boiler furnace can be obtained using a novel flame image processing technique. Briefly, we first outline the visualization principle. Then, the hardware and software design of the system in a 300 MW twin-furnace coal-fired boiler are introduced in detail. The visualization of the 3-D temperature distribution in the twin-furnace boiler is realized with an industrial computer and the Distributed Control System (DCS) of the boiler. The practical operation of the system shows that it can provide valuable combustion information of a furnace and is useful for the combustion diagnosis and adjustment in coal-fired power plants. 展开更多
关键词 thermal power engineering combustion monitoring system 3-D temperature distribution CCD camera flame imageprocessing technique
下载PDF
Geotechnical characterization of peat-based landfill cover materials 被引量:2
8
作者 Afshin Khoshand Mamadou Fall 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2016年第5期596-604,共9页
Natural methane (CH4) oxidation that is carried out through the use of landfill covers (biocovers) is a promising method for reducing CH4 emissions from landfills. Previous studies on peat-based landfill covers ha... Natural methane (CH4) oxidation that is carried out through the use of landfill covers (biocovers) is a promising method for reducing CH4 emissions from landfills. Previous studies on peat-based landfill covers have mainly focused on their biochemical properties (e.g. CH4 oxidation capacity). However, the utilization of peat as a cover material also requires a solid understanding of its geotechnical properties (thermal, hydraulic, and mechanical), which are critical to the performance of any biocover. Therefore, the objective of this context is to investigate and assess the geotechnical properties of peat-based cover materials (peat, peat–sand mixture), including compaction, consolidation, and hydraulic and thermal conductivities. The studied materials show high compressibility to the increase of vertical stress, with compression index (Cc) values ranging from 0.16 to 0.358. The compressibility is a function of sand content such that the peat–sand mixture (1:3) has the lowest Cc value. Both the thermal and hydraulic conductivities are functions of moisture content, dry density, and sand content. The hydraulic conductivity varies from 1.74 × 10^-9 m/s to 7.35 × 10^-9 m/s, and increases with the increase in sand content. The thermal conductivity of the studied samples varies between 0.54 W/(m K) and 1.41 W/(m K) and it increases with the increases in moisture and sand contents. Increases in sand content generally increase the mechanical behavior of peat-based covers; however, they also cause relatively high hydraulic and thermal conductivities which are not favored properties for biocovers. 展开更多
关键词 Landfill Geotechnical engineering Landfill cover Peat Compaction Compressibility Hydraulic and thermal conductivity
下载PDF
Analog-experiment analysis of ash-deposition monitoring model of boiler economizers in power plants
9
作者 程伟良 夏国栋 徐寿臣 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2005年第6期680-683,共4页
Ash deposition is a form of particulate fouling, and appears usually in boiler economizers. The ash deposition increases capital expenditure, energy input and maintenance costs. An analog experiment for monitoring ash... Ash deposition is a form of particulate fouling, and appears usually in boiler economizers. The ash deposition increases capital expenditure, energy input and maintenance costs. An analog experiment for monitoring ash deposition was performed from the analogous objective of a 410 t/h boiler economizer to verify the rationality and reliability of the ash-deposition-monitoring model presented in order to increase the security and economy in economizer running. The analog experiment platform is a tube-shell exchanger that conforms well to the conditions of a self-modeling area. The analog flue gas in the shell side is the heated air mixed with ash, and in the tube side the fluid is water heated by the flue gas. The fluid state in the water side and the flue gas side follows the second self-modeling area. A 4-factor-3-level orthogonal table was used to schedule 9 operation conditions of orthogonal experiment, with the 4 factors being heat power, flue gas velocity, ashes grain diameter and adding ashes quantity while the three levels are different values due to different position classes in every factor. The ash deposition thermal resistances is calculated by the model with the measure parameters of temperature and pressure drop. It shows that the values of the ash deposition thermal resistances gradually increase up to a stable state. And the experimental results are reliable by F testing method at α= 0.001. Therefore, the model can be applied in online monitoring of ash deposition in a boiler economizers in power plants and provides scientific decision on ash deposition prediction and sootblowing. 展开更多
关键词 thermal power engineering monitoring model ash deposition orthogonal experiment boiler economizer tube-shell exchanger
下载PDF
上一页 1 下一页 到第
使用帮助 返回顶部