Several industrial computers and a server are combined to set up the on-line monitoring and diagnostic system of turbo-generator sets. The main function of the system is to monitor machine sets' running condition....Several industrial computers and a server are combined to set up the on-line monitoring and diagnostic system of turbo-generator sets. The main function of the system is to monitor machine sets' running condition. Through analyzing running data, technicians can detect whether there exist faults and where they occur. To share and transmit the dynamic information of the turbo-generator sets, a distributed network system is introduced. NetWare network operating system is used in the LAN (Local Area Network) system. The LAN is extended to realize the sharing of data and remote transmission of information. Furthermore, functions of monitoring and diagnostic clients are listed.展开更多
This paper presents an on-line failure diagnostic method for steam turbine hydraulic governing system. This method uses the estimated values of friction on sliding valves to calculuate the corresponding dead band. Und...This paper presents an on-line failure diagnostic method for steam turbine hydraulic governing system. This method uses the estimated values of friction on sliding valves to calculuate the corresponding dead band. Under load rejection, the steam turbine's additional overspeed caused by these dead bands are studied through computer simulation. This on-line detection of dead bands can realize the failure detection of blockage fault of sliding valves.展开更多
The measuring principle and experimental results of the enthalpy probe technique for thermal plasma diagnostics are presented. Its calibration and errors are discussed. Typical results are presented for the system ope...The measuring principle and experimental results of the enthalpy probe technique for thermal plasma diagnostics are presented. Its calibration and errors are discussed. Typical results are presented for the system operation in an Ar/H2(5 % H2) plasma arc jet under a reactor chamber pressure of 101.3 kPa. The plasma temperature and velocity profiles are measured. The center temperature and velocity are 6600 K and 850 m/s for plasma power 9 kW at axial location of 17 mm.展开更多
The present work establishes a systematic approach based on the application of in-situ Fourier transform infrared spectroscopy (FTIR) for the investigation of the crystal structure, thermal stability, redox behavior...The present work establishes a systematic approach based on the application of in-situ Fourier transform infrared spectroscopy (FTIR) for the investigation of the crystal structure, thermal stability, redox behavior (temperature-programmed reduction/temperatureprogrammed re-oxidation) as well as the catalytic properties of Co3O4 thin films. The syntheses of Co3O4 were achieved by chemical vapor deposition in the temperature range of 400-500℃. The structure analysis of the as-prepared material revealed the presence of two prominent IR bands peaking at 544 cm-1 (υ1) and 650 cm-1 (υ2) respectively, which originate from the stretching vibrations of the Co-O bond, characteristic of the Co3O4 spinel. The lattice stability limit of Co3O4 was estimated to be above 650℃. The redox properties of the spinel structure were determined by integrating the area under the emission bands υ1 and υ2 as a function of the temperature. Moreover, Co3O4 has been successfully tested as a catalyst towards complete oxidation of dimethyl ether below 340 ℃. The exhaust gas analysis during the catalytic process by in situ absorption FTIR revealed that only CO2 and H2O were detected as the final products in the catalytic reaction. The redox behavior suggests that the oxidation of dimethyl ether over Co3O4 follows a Mars-van Krevelen type mechanism. The comprehensive application of in situ FTIR provides a novel diagnostic tool in characterization and performance test of catalysts.展开更多
This paper introduces a computerized on-line partial discharge (PD) monitoring and diagnostic system for transformers. The system, which is already in use in a power station, uses wide-band active transducers and a ...This paper introduces a computerized on-line partial discharge (PD) monitoring and diagnostic system for transformers. The system, which is already in use in a power station, uses wide-band active transducers and a data acquisition unit with modularized and exchangeable components. The system software is a power equipment monitoring and diagnostic system, which is based on the component object model, and was developed for monitoring multiple parameters in multiple power supply systems. The statistical characteristics of PDs in power transformers were studied using 7 experimental models for simulating PDs in transformers and 3 models for simulating interfering discharges in air. The discharge features were analyzed using a 3-D pattern chart with a three-layer back-propagation artificial neural network used to recognize the patterns. The results show that PDs in air and oil can be distinguished. The model can be used for interference rejection on-line monitoring of partial discharge in transformers.展开更多
We propose a novel on-line beam diagnostic method based on single-shot beam splitting phase retrieval. The incident beam to be measured is diffracted into many replicas by a Dammann grating and then propagates through...We propose a novel on-line beam diagnostic method based on single-shot beam splitting phase retrieval. The incident beam to be measured is diffracted into many replicas by a Dammann grating and then propagates through a weakly scattering phase plate with a known structure; the exiting beams propagate along their original direction and form an array of diffraction patterns on the detector plane. By applying the intensity of diffraction patterns into an iterative algorithm and calculating between the grating plane, weakly scattering plane, and detector plane, the complex field of the incident beam can be reconstructed rapidly; the feasibility of this method is verified experimentally with wavelengths of 1053 and 632.8 nm.展开更多
With the portable Fourier Transform Infrared Spectroscopy (FTIR), the reflectance spectra of soil samples with different moisture content are measured in laboratory for expounding the characteristic of radiation in th...With the portable Fourier Transform Infrared Spectroscopy (FTIR), the reflectance spectra of soil samples with different moisture content are measured in laboratory for expounding the characteristic of radiation in the thermal infrared part of the spectrum with different soil moisture content. A model of estimating the moisture content in soil is attempted to make based on Moisture Diagnostic Index (MDI). In general,the spectral characteristic of soil emissivity in laboratory includes the following aspects.Firstly,in the region of 8.0-9.5 μm,along with the increase of soil moisture content,the emissivity of soil increases to varying degrees. The spectral curves are parallel relatively and have a tendency to become horizontal and the absorbed characteristic of reststrahlen is also weakened relatively with the increase of soil moisture in this region.Secondly,in the region of 11.0-14.0 μm,the emissivity of soil has a tendency of increasing.There is an absorption value near about 12.7 μm. As the soil moisture content increases,the depth of absorption also increases. This phenomenon may be caused by soil moisture absorption. Methods as derivative, difference and standardized ratio transformation may weaken the background noise effectively to the spectrum data. Especially using the ratio of the emissivity to the average of 8-14 μm may obviously enhance the correlation between soil moisture and soil emissivity. According to the result of correlation analysis, the 8.237 μm is regarded as the best detecting band for soil moisture content. Moreover,based on the Moisture Diagnostic Index ( MDI) in the 8.194-8.279 μm, the logarithmic model of estimating soil moisture is made.展开更多
文摘Several industrial computers and a server are combined to set up the on-line monitoring and diagnostic system of turbo-generator sets. The main function of the system is to monitor machine sets' running condition. Through analyzing running data, technicians can detect whether there exist faults and where they occur. To share and transmit the dynamic information of the turbo-generator sets, a distributed network system is introduced. NetWare network operating system is used in the LAN (Local Area Network) system. The LAN is extended to realize the sharing of data and remote transmission of information. Furthermore, functions of monitoring and diagnostic clients are listed.
文摘This paper presents an on-line failure diagnostic method for steam turbine hydraulic governing system. This method uses the estimated values of friction on sliding valves to calculuate the corresponding dead band. Under load rejection, the steam turbine's additional overspeed caused by these dead bands are studied through computer simulation. This on-line detection of dead bands can realize the failure detection of blockage fault of sliding valves.
文摘The measuring principle and experimental results of the enthalpy probe technique for thermal plasma diagnostics are presented. Its calibration and errors are discussed. Typical results are presented for the system operation in an Ar/H2(5 % H2) plasma arc jet under a reactor chamber pressure of 101.3 kPa. The plasma temperature and velocity profiles are measured. The center temperature and velocity are 6600 K and 850 m/s for plasma power 9 kW at axial location of 17 mm.
文摘The present work establishes a systematic approach based on the application of in-situ Fourier transform infrared spectroscopy (FTIR) for the investigation of the crystal structure, thermal stability, redox behavior (temperature-programmed reduction/temperatureprogrammed re-oxidation) as well as the catalytic properties of Co3O4 thin films. The syntheses of Co3O4 were achieved by chemical vapor deposition in the temperature range of 400-500℃. The structure analysis of the as-prepared material revealed the presence of two prominent IR bands peaking at 544 cm-1 (υ1) and 650 cm-1 (υ2) respectively, which originate from the stretching vibrations of the Co-O bond, characteristic of the Co3O4 spinel. The lattice stability limit of Co3O4 was estimated to be above 650℃. The redox properties of the spinel structure were determined by integrating the area under the emission bands υ1 and υ2 as a function of the temperature. Moreover, Co3O4 has been successfully tested as a catalyst towards complete oxidation of dimethyl ether below 340 ℃. The exhaust gas analysis during the catalytic process by in situ absorption FTIR revealed that only CO2 and H2O were detected as the final products in the catalytic reaction. The redox behavior suggests that the oxidation of dimethyl ether over Co3O4 follows a Mars-van Krevelen type mechanism. The comprehensive application of in situ FTIR provides a novel diagnostic tool in characterization and performance test of catalysts.
基金Supported by the National Natural Science Foundation of China, the Northeastern Electric Power Corp. (Group) (No. 59637200), and the National Foundation of USA
文摘This paper introduces a computerized on-line partial discharge (PD) monitoring and diagnostic system for transformers. The system, which is already in use in a power station, uses wide-band active transducers and a data acquisition unit with modularized and exchangeable components. The system software is a power equipment monitoring and diagnostic system, which is based on the component object model, and was developed for monitoring multiple parameters in multiple power supply systems. The statistical characteristics of PDs in power transformers were studied using 7 experimental models for simulating PDs in transformers and 3 models for simulating interfering discharges in air. The discharge features were analyzed using a 3-D pattern chart with a three-layer back-propagation artificial neural network used to recognize the patterns. The results show that PDs in air and oil can be distinguished. The model can be used for interference rejection on-line monitoring of partial discharge in transformers.
基金supported by the National Natural Science Foundation of China(No.61675215)the Shanghai Sailing Program(No.18YF1426600)
文摘We propose a novel on-line beam diagnostic method based on single-shot beam splitting phase retrieval. The incident beam to be measured is diffracted into many replicas by a Dammann grating and then propagates through a weakly scattering phase plate with a known structure; the exiting beams propagate along their original direction and form an array of diffraction patterns on the detector plane. By applying the intensity of diffraction patterns into an iterative algorithm and calculating between the grating plane, weakly scattering plane, and detector plane, the complex field of the incident beam can be reconstructed rapidly; the feasibility of this method is verified experimentally with wavelengths of 1053 and 632.8 nm.
基金Supported by Special Fund for Doctors by Educational Department(20050319003)
文摘With the portable Fourier Transform Infrared Spectroscopy (FTIR), the reflectance spectra of soil samples with different moisture content are measured in laboratory for expounding the characteristic of radiation in the thermal infrared part of the spectrum with different soil moisture content. A model of estimating the moisture content in soil is attempted to make based on Moisture Diagnostic Index (MDI). In general,the spectral characteristic of soil emissivity in laboratory includes the following aspects.Firstly,in the region of 8.0-9.5 μm,along with the increase of soil moisture content,the emissivity of soil increases to varying degrees. The spectral curves are parallel relatively and have a tendency to become horizontal and the absorbed characteristic of reststrahlen is also weakened relatively with the increase of soil moisture in this region.Secondly,in the region of 11.0-14.0 μm,the emissivity of soil has a tendency of increasing.There is an absorption value near about 12.7 μm. As the soil moisture content increases,the depth of absorption also increases. This phenomenon may be caused by soil moisture absorption. Methods as derivative, difference and standardized ratio transformation may weaken the background noise effectively to the spectrum data. Especially using the ratio of the emissivity to the average of 8-14 μm may obviously enhance the correlation between soil moisture and soil emissivity. According to the result of correlation analysis, the 8.237 μm is regarded as the best detecting band for soil moisture content. Moreover,based on the Moisture Diagnostic Index ( MDI) in the 8.194-8.279 μm, the logarithmic model of estimating soil moisture is made.