The essential requirements for evaluating the sustainable development of a system and the thermodynamic framework of the energy conservation mechanism in the waste-removal process are proposed.A thermodynamic method o...The essential requirements for evaluating the sustainable development of a system and the thermodynamic framework of the energy conservation mechanism in the waste-removal process are proposed.A thermodynamic method of analysis based on the first and second laws of thermodynamics is suggested as a means to analyze the theoretical energy consumption for the removal of organic contaminants by physical methods.Moreover,the theoretical energy consumption for the removal by physical methods of different kinds of representative organic contaminants with different initial concentrations and amounts is investigated at 298.15 K and 1.01325 × 105 Pa.The results show that the waste treatment process has a high energy consumption and that the theoretical energy consumption for the removal of organic contaminants increases with the decrease of their initial concentrations in aqueous solutions.The theoretical energy consumption for the removal of different organic contaminants varies dramatically.Furthermore,the theoretical energy consumption increases greatly with the increase in the amount to be removed.展开更多
This study focuses on the heat transfer characteristics of the evaporation terminal,the cool distribute unit(CDU)and refrigerant flow distribution of a water cooled multi-spilit heat pipe system(MSHPS)used in data cen...This study focuses on the heat transfer characteristics of the evaporation terminal,the cool distribute unit(CDU)and refrigerant flow distribution of a water cooled multi-spilit heat pipe system(MSHPS)used in data center.The finite time thermodynamic analysis,the exergy method and the software SIMULINK was employed to build the simulation model of the combined system.The results show that the IT servers should concentrate on arranging at the location below 1.3 m.The CDU has a heat transfer of about 74 J in a period of 6 s.And the optimum flow rate of the CDU is 0.82 kg/s.The flow distribution characteristic of a CDU which connect 2 heat pipe evaporator terminals of 6 kW was calculated,and the working fluid is R22.Then the free cooling time,part time free cooling and energy saving potential in major cities of China were analysised.The energy saving potential is from 61%to 25%.The results are of great significance for the operational control and practical application of a MSHPS and other pipe-net systems.展开更多
基金supported by the Chinese National Key Technology Research and Development Program (2006AA03Z455)National Basic Research Program of China (No 2009CB226103)+2 种基金the National Natural Science Foundation of China (20976080)NSFC-RGC (No 20731160614)the Program for Changjiang Scholars and Innovative Research Teams in University (No IRT0732)
文摘The essential requirements for evaluating the sustainable development of a system and the thermodynamic framework of the energy conservation mechanism in the waste-removal process are proposed.A thermodynamic method of analysis based on the first and second laws of thermodynamics is suggested as a means to analyze the theoretical energy consumption for the removal of organic contaminants by physical methods.Moreover,the theoretical energy consumption for the removal by physical methods of different kinds of representative organic contaminants with different initial concentrations and amounts is investigated at 298.15 K and 1.01325 × 105 Pa.The results show that the waste treatment process has a high energy consumption and that the theoretical energy consumption for the removal of organic contaminants increases with the decrease of their initial concentrations in aqueous solutions.The theoretical energy consumption for the removal of different organic contaminants varies dramatically.Furthermore,the theoretical energy consumption increases greatly with the increase in the amount to be removed.
基金Thanks for the support of Hunan postdoctoral fund(Number:198514)。
文摘This study focuses on the heat transfer characteristics of the evaporation terminal,the cool distribute unit(CDU)and refrigerant flow distribution of a water cooled multi-spilit heat pipe system(MSHPS)used in data center.The finite time thermodynamic analysis,the exergy method and the software SIMULINK was employed to build the simulation model of the combined system.The results show that the IT servers should concentrate on arranging at the location below 1.3 m.The CDU has a heat transfer of about 74 J in a period of 6 s.And the optimum flow rate of the CDU is 0.82 kg/s.The flow distribution characteristic of a CDU which connect 2 heat pipe evaporator terminals of 6 kW was calculated,and the working fluid is R22.Then the free cooling time,part time free cooling and energy saving potential in major cities of China were analysised.The energy saving potential is from 61%to 25%.The results are of great significance for the operational control and practical application of a MSHPS and other pipe-net systems.