Current practice of underground artificial ground freezing(AGF)typically involves huge refrigeration systems of large economic and environmental costs.In this study,a novel AGF technique is proposed deploying availabl...Current practice of underground artificial ground freezing(AGF)typically involves huge refrigeration systems of large economic and environmental costs.In this study,a novel AGF technique is proposed deploying available cold wind in cold regions.This is achieved by a static heat transfer device called thermosyphon equipped with an air insulation layer.A refrigeration unit can be optionally integrated to meet additional cooling requirements.The introduction of air insulation isolates the thermosyphon from ground zones where freezing is not needed,resulting in:(1)steering the cooling resources(cold wind or refrigeration)towards zones of interest;and(2)minimizing refrigeration load.This design is demonstrated using well-validated mathematical models from our previous work based on two-phase enthalpy method of the ground coupled with a thermal resistance network for the thermosyphon.Two Canadian mines are considered:the Cigar Lake Mine and the Giant Mine.The results show that our proposed design can speed the freezing time by 30%at the Giant Mine and by two months at the Cigar Lake Mine.Further,a cooling load of 2.4 GWh can be saved at the Cigar Lake Mine.Overall,this study provides mining practitioners with sustainable solutions of underground AGF.展开更多
Two-phase closed thermosyphons(TPCTs)are widely used in infrastructure constructions in permafrost regions.Due to different climatic conditions,the effectiveness of TPCT will also be different,especially in the extrem...Two-phase closed thermosyphons(TPCTs)are widely used in infrastructure constructions in permafrost regions.Due to different climatic conditions,the effectiveness of TPCT will also be different,especially in the extremely cold region of the Da Xing'anling Mountains.In this study,a series of three-dimensional finite element TPCT embankment models were established based on the ZhanglingMohe highway TPCT test section in Da Xing'anling Mountains,and the thermal characteristics and the cooling effect of the TPCTs were analyzed.The results indicated that the TPCTs installed in the northeastern high-latitude regions is effective in cooling and stabilizing the embankment.The working cycle of the TPCTs is nearly 7 months,and the cooling range of the TPCTs can reach 3 m in this region.However,due to the extremely low temperature,the TPCT generates a large radial gradient in the permafrost layer.Meanwhile,by changing the climate conditions,the same type of TPCT embankment located in the Da Xing'anling Mountains,the Xiao Xing'anling Mountains,and the Qinghai-Tibet Plateau permafrost regions were simulated.Based on the comparison of the climate differences between the Qinghai-Tibet Plateau and Northeast China,the differences in the effectiveness of TPCTs were studied.Finally,the limitations of using existing TPCTs in high-latitude permafrost regions of China were discussed and the potential improvements of the TPCT in cold regions were presented.展开更多
With the completion of the Qinghai-Tibetan Railway,economic development of related areas has been greatly accelerated.This,in return,calls for building or upgrading more roadways,especially high-grade roadways.In cold...With the completion of the Qinghai-Tibetan Railway,economic development of related areas has been greatly accelerated.This,in return,calls for building or upgrading more roadways,especially high-grade roadways.In cold regions,the thawing of permafrost can induce settlement damage of and even failure to railway (or roadway) embankments.Thermosyphons (self-powered refrigera-tion devices that are used to help keep the permafrost cool) have proved effective in mitigating thaw settlement by maintaining the thermal stability of the embankments.However,for high-grade roadway embankments of great width,stabilizing or cooling ef-fects of traditional geotechnological measures may be limited.To enhance the cooling effect of thermosyphons,an L-shaped thermosyphon was designed.A laboratory test was carried out to study the combined cooling effect of the L-shaped thermosyphon and thermal insulation applying to roadbed construction.The angle between the evaporator and condenser sections of the L-shaped thermosyphon is 134 degrees,and the L-shaped thermosyphon was inserted into the soil at an angle of 5 degrees with the road surface.The tested results show that the L-shaped thermosyphon is effective in removing heat from a roadway in winter.When the ambient air temperature is lower than the soil temperature,the thermosyphon is active and extracts the heat in the soil around it.When the ambient air temperature is higher than the soil temperature,the thermosyphon is inactive,and no heat is in-jected into the soil through the L-shaped thermosyphon.Compared to embankments with straight thermosyphons,the inner parts of the embankments with L-shaped thermosyphons were significantly cooled.It is hoped that the present study would be useful to the application of L-shaped thermosyphons in the construction of high-grade roadways in cold regions.展开更多
1 INTRODUCTIONClosed thermosyphon has been developed to enhance heat transfer and recover wasteheat in various process industries [1,2].Stimulated by this success,a new type oftwo-phase closed thermosyphon was designe...1 INTRODUCTIONClosed thermosyphon has been developed to enhance heat transfer and recover wasteheat in various process industries [1,2].Stimulated by this success,a new type oftwo-phase closed thermosyphon was designed by inserting respectively two inner tubesinto the thermosyphon,one in the boiling section and the other in the condensing sec-tion.The two-phase flow boiling heat transfer coefficient was calculated successfully onthe basis of Chen’s dual-mechanism [3].A boiling heat transfer model for thetwo-phase closed thermosyphon with an inner tube in the boiling section was pro-展开更多
An experimental system was set up to measure the temperature, pressure, heat transfer rate and mass flow rate in a semi-open two-phase thermosyphon. The behaviors of a semi-open two-phase thermosyphon during startup, ...An experimental system was set up to measure the temperature, pressure, heat transfer rate and mass flow rate in a semi-open two-phase thermosyphon. The behaviors of a semi-open two-phase thermosyphon during startup, shutdown and lack of water were studied to get complete understanding of its thermal characteristics. The variation of wall temperature, heat-exchange condition and pressure fluctuations of semi-open two-phase thermosyphons showed that the startup of SOTPT needs about 60-70 min; the startup speed of SOTPT is determined by the startup speed of the condensation section; the average pressure in the heat pipe is equal to the environmental pressure usually; the shutdown of SOTPT needs about 30-50min; a semi-open two-phase thermosyphon has good response to lack of water accident.展开更多
The thaw settlement of pipeline foundation soils in response to the operation of the first China-Russia Crude Oil Pipeline along the eastern flank of the northern Da Xing'anling Mountains in Northeast China was si...The thaw settlement of pipeline foundation soils in response to the operation of the first China-Russia Crude Oil Pipeline along the eastern flank of the northern Da Xing'anling Mountains in Northeast China was simulated in a physical model test(with a similitude ratio of 1/73) in a geotechnical centrifuge. Two pipes of a supported and an unsupported section were evaluated over a testing period for simulating 20 years of actual pipeline operation with seasonal cyclically changing oil and ambient temperatures. The results show that pipe settlement of the supported pipe was 45% of settlement of the unsupported pipe. Settlement for the unsupported section was approximately 35% of the thaw bulb depth below the initial pipe elevation, only 30% of that for the supported pipe due to the influence of the supports. The final thaw bulbs extended approximately 3.6 and 1.6 times of the pipe diameter below the unsupported and supported pipe bottom elevations, respectively. The sandbag supports kept frozen during the test period because of cooling effect of the thermosyphons. The maximum bending stress induced over the 20 m span length from bearing of the full cover over the pipe would be equivalent to40% specified minimum yield strength(SMYS). Potential buckling of the pipe should be considered as the ground thaws.This study also offers important data for calibration and validation of numerical simulation models.展开更多
A thermal model has been developed to study the thermal behavior of Thermosyphon integrated Heat Sink during CPU cooling. An Indirect cooling module has been experimentally studied and analyzed under steady state cond...A thermal model has been developed to study the thermal behavior of Thermosyphon integrated Heat Sink during CPU cooling. An Indirect cooling module has been experimentally studied and analyzed under steady state condition for both natural and forced convection. The thermal model is employed to determine the actual heat transfer and the effectiveness of the present model and compared it with the conventional cooling method and found that there is an appreciable improvement in the present model.展开更多
Snow covers the road embankments in winter in high latitude permafrost zones. The effect of snow cover on embankments was simulated based on field measurements of boundary conditions and initial ground temperature pro...Snow covers the road embankments in winter in high latitude permafrost zones. The effect of snow cover on embankments was simulated based on field measurements of boundary conditions and initial ground temperature profile in Mohe,China. The effect of thermosyphons on the embankment warmed by snow cover was evaluated by numerical simulations as well. The results indicate that the difference of thermal regimes between non-thermosyphon and thermosyphon embankments reaches to 22 m in depth below the ground surface. It is much warmer in the non-thermosyphon embankment body in winter. Affected by the snow cover, heat flux gradually spreads into the deep ground of the subgrade over time. The permafrost table under the slope toe of a thermosyphon embankment is 1.2 m higher than that of a non-thermosyphon embankment in the 20 th year. In addition, the permafrost table at the slope toe of a thermosyphon embankment is 26 cm deeper over 20 years. These results indicate that thermosyphons can greatly weaken the warm effect of snow cover. However,thermosyphons cannot avoid the degradation of permafrost under the scenarios of snow cover. Therefore, composite measures need to be adopted to keep embankment stability in snowy permafrost zones.展开更多
Compared with a conventional single section two-phase closed thermosyphon (TPCT) wellbore, a two-section TPCT wellbore has better heat transfer performance, which may improve the temperature distribution of fluid in...Compared with a conventional single section two-phase closed thermosyphon (TPCT) wellbore, a two-section TPCT wellbore has better heat transfer performance, which may improve the temperature distribution of fluid in wellbores, increase the temperature of fluid in wellheads and even more effectively reduce the failure rate of conventional TPCT wellbores. Heat transfer performance of two-section TPCT wellbores is affected by working medium, combination mode and oil flow rate. Different working media are introduced into the upper and lower TPCTs, which may achieve a better match between the working medium and the temperature field in the wellbores. Interdependence exists between the combination mode and the flow rate of the oil, which affects the heat transfer performance of a two-section TPCT wellbore. The experimental results show that a two-section TPCT wellbore, with equal upper and lower TPCTs respectively filled with Freon and methanol, has the best heat transfer performance when the oil flow rate is 200 L/h.展开更多
With rapid development of the semiconductor technology, more efficient cooling systems for electronic devices are needed. In this situation, in the present study, a loop thermosyphon type cooling system, which is comp...With rapid development of the semiconductor technology, more efficient cooling systems for electronic devices are needed. In this situation, in the present study, a loop thermosyphon type cooling system, which is composed mainly of a heating block, an evaporator and an air-cooled condenser, is investigated experimentally in order to evaluate the cooling performance. At first, it is examined that the optimum volume filling rate of this cooling system is approximately 40%. Next, four kinds of working fluids, R1234ze(E), R1234ze(Z), R134a and ethanol, are tested using a blasted heat transfer surface of the evaporator. In cases of R1234ze(E), R1234ze(Z), R134a and ethanol, the effective heat flux, at which the heating block surface temperature reaches 70°C, is 116 W/cm2, 106 W/cm2, 104 W/cm2 and 60 W/cm2, respectively. This result indicates that R1234ze(E) is the most suitable for the present cooling system. The minimum boiling thermal resistance of R1234ze(E) is 0.05 (cm2·K)/W around the effective heat flux of 100 W/cm2. Finally, four kinds of heat transfer surfaces of the evaporator, smooth, blasted, copper-plated and finned surfaces, are tested using R1234ze(E) as working fluid. The boiling thermal resistance of the blasted surface is the smallest among tested heat transfer surfaces up to 116 W/cm2 in effective heat flux. However, it increases drastically due to the appearance of dry-patch if the effective heat flux exceeds 116 W/cm2. On the other hand, in cases of copper-plated and finned surfaces, the dry-patch does not appear up to 150 W/cm2 in effective heat flux, and the boiling thermal resistances of those surfaces keep 0.1 (cm2·K)/W.展开更多
We have developed a loop thermosyphon for cooling electronic devices. The cooling performance of a thermosyphon deteriorates with an increasing amount of non-condensable gas (NCG). Design of a thermosyphon must consid...We have developed a loop thermosyphon for cooling electronic devices. The cooling performance of a thermosyphon deteriorates with an increasing amount of non-condensable gas (NCG). Design of a thermosyphon must consider NCG to provide guaranteed performance for a long time. In this study, the heat transfer performance of a thermosyphon was measured while changing the amount of NCG. The resultant performances were expressed as approximations. These approximations enabled us to predict the total thermal resistance of the thermosyphon by the amount of NCG and input heating. Then, using the known leakage in the thermosyphon and the amount of dissolved NCG in the water, we can predict the amount of NCG and the total thermal resistance of the thermosyphon after ten years. Although there is a slight leakage in the thermosyphon, we are able to design a thermosyphon with a guaranteed level of cooling performance for a long time using the proposed design method.展开更多
Heat transfer and hydrodynamics of two phase closed thermosyphon (TPCT) is studied using finite difference method of Stream function and vorticity. The mathematical model is formed for both vapor phase and liquid fi...Heat transfer and hydrodynamics of two phase closed thermosyphon (TPCT) is studied using finite difference method of Stream function and vorticity. The mathematical model is formed for both vapor phase and liquid film in a non-dimensional form. The momentum and energy equations as parabolic equations have been solved by means of the locally one-dimensional scheme of A.A. Samarskii. The Poisson equation for the stream function has been approximated on the basis of the discrete scheme "cross". The obtained system of algebraic equations has been solved by the successive over relaxation method. The effect of the Rayleigh number on the velocity and temperature fields in the domain of interest and on the average Nusselt number at the solid-fluid interfaces is investigated. It was found that increase in the Rayleigh number leads to the increment of both the average Nusselt number and the stream function in the vapor zone.展开更多
The heat losses density in power electronics products follows an ever increasing trend. Nowadays they reach 200 W/cmz at chip level and 50 W/cm2 at heatsink base level. Water cooling is the most effective cooling meth...The heat losses density in power electronics products follows an ever increasing trend. Nowadays they reach 200 W/cmz at chip level and 50 W/cm2 at heatsink base level. Water cooling is the most effective cooling method but unfortunately water is often undesired due to high voltages or costumer requirements. Two-phase cooling is a promising technology for electronics cooling. It allows using dielectric fluids in passive systems and still benefits from very high heat transfer coefficients. Thermosyphons are a particularly interesting technology in the field of power electronics because it is entirely passive and a simple equipment. ABB has developed a compact thermosyphon heat exchanger based on automotive technology, which uses numerous multi-port extruded tubes with capillary sized channels disposed in parallel and brazed to a heated base plate in order to achieve the desired compactness. The experimental performances of this novel power electronics cooling system are presented with R134a as a working fluid. The influence of several parameters on the performances was studied experimentally: coolant flow rate, coolant temperature, heat load and fluid filling.展开更多
To ensure the long-term service performance of infrastructure such as railways,highways,airports and oil pipelines built on permafrost slope wetland sites,it is imperative to systematically uncover the long-term heat-...To ensure the long-term service performance of infrastructure such as railways,highways,airports and oil pipelines built on permafrost slope wetland sites,it is imperative to systematically uncover the long-term heat-water changes of soil in slope wetlands environment under climate warming.More specifically,considering valuable field data from 2001 to 2019,the long-term heat and water changes in active layers of the slope wetland site along the Qinghai-Xizang Railway(QXR)are illustrated,the effect of thermosyphon measures in protecting the permafrost environment is evaluated,and the influences of climate warming and hydrological effects on the stability of slope wetland embankments are systematically discussed.The permafrost at the slope wetland site is rapidly degrading,demonstrating a reduction in active layer thickness of>3.7 cm per year and a permafrost temperature warming of>0.006℃ per year.The thermosiphon embankment developed by QXR has a specific cooling period;thus,to mitigate the long-term impacts of climate warming on the thermal stability of permafrost foundation,it is essential to implement strengthening measures for the thermosiphon embankment,such as adding a crushed-rock layer or sunshade board on the slope of thermosiphon embankment to creating a composite cooling embankment.Short-term seasonal groundwater seepage intensifies frost damage to the slope wetland embankment,while long-term seasonal supra-permafrost water and groundwater seepage exacerbates uneven transverse deformation of slope wetland embankment.Long-term climate warming and slope effects have altered the surface water and groundwater hydrological processes of slope wetlands,potentially leading to an increased occurrence of slope embankment instability.These results are crucial for improving our understanding of heat and water variation processes in the active layer of slope wetland sites located in permafrost regions and ensuring long-term service safety for the QXR.展开更多
Over the years,numerous geotechnical approaches have been implemented to mitigate the adverse effects of climate warming on various infrastructures in the permafrost region of the Qinghai-Tibet Plateau(QTP),such as th...Over the years,numerous geotechnical approaches have been implemented to mitigate the adverse effects of climate warming on various infrastructures in the permafrost region of the Qinghai-Tibet Plateau(QTP),such as the Qinghai-Tibet Highway and Railway,and achieved the expected engineering outcomes.However,little attention has been given to whether the performance of these geotechnical approaches has changed during the ongoing process of climate warming.To investigate the performance variation of one of these geotechnical approaches,which is two-phase closed thermosyphon(TPCT),during sustained climate warming,we conducted a statistical analysis of soil temperature monitoring data in 2003-2020 from eight regular embankments and six TPCT embankments in our permafrost monitoring network.The results indicate that TPCT undeniably has a cooling effect on the permafrost beneath embankments,even rapidly eliminated previously formed taliks beneath embankment.However,further analysis reveals that the performance of TPCT has been weakening during sustained climate warming,which has confirmed by the re-forming of the taliks beneath embankment where they had been previously eliminated.Based on the current understanding,we attributed the weakening of thermosyphon performance to a significant reduction in the air temperature freezing index caused by ongoing climate warming.Through this study,we aimed to draw attention to the evolving performance of geotechnical approaches in permafrost regions amid climate warming,prompting necessary engineering innovations to address this situation and ensure the sustainable development of the permafrost region on the QTP.展开更多
Experiments were conducted in this study to examine the thermal performance of a thermosyphon,made from Inconel alloy 625,could recover waste heat from automobile exhaust using a limited amount of fluid.The thermosyph...Experiments were conducted in this study to examine the thermal performance of a thermosyphon,made from Inconel alloy 625,could recover waste heat from automobile exhaust using a limited amount of fluid.The thermosyphon has an outer diameter of 27 mm,a thickness of 2.6 mm,and an overall length of 483 mm.The study involved directing exhaust gas onto the evaporator.This length includes a 180-mm evaporator,a 70-mm adiabatic section,a 223-mm condenser,and a 97-mm finned exchanger.The study examined the thermal performance of the thermosyphon under exhaust flow rates ranging from 0–10 g/sec and temperatures varying from 300℃–900℃.The influence of three parameters—inclination angle(5°–45°),water mass(2–5.3 g),and the quantity of non-condensable gas Argon(0–0.6 g)—was investigated to assess their impacts on the thermosyphon’s thermal efficiency.The experimental findings revealed that with 3 g of water and 0.0564 g of argon in the thermosyphon,the condenser reached its highest temperature at around 200℃.The ideal fuel loading rate for the thermosyphon falls between 0.2 and 0.7 g/s.Moreover,as inclination angles rise,outer wall temperatures of the thermosyphon increase.This is attributed to the explicit expansion of the effective heating area within the evaporation section,coupled with an amplified gravitational component of the water flux.Additionally,an upsurge in the quantity of non-condensable gas(NCG)can mitigate temperature gradients on the outer wall,resulting in a decline in the thermosyphon’s performance.The insulation applied to the adiabatic section demonstrated efficacy in augmenting temperature gradients on the outer wall,thereby improving the overall performance of the thermosyphon.As the water charge within the thermosyphon increases,there is a corresponding rise in heat transfer rates both from the exhaust to the thermosyphon and from the thermosyphon to the fuel.展开更多
The embankment of the Qinghai-Tibet Railway(QTR)has been experiencing severe problems due to permafrost degradation,especially in warm and ice-rich permafrost regions.Based on ground temperature and deformation data o...The embankment of the Qinghai-Tibet Railway(QTR)has been experiencing severe problems due to permafrost degradation,especially in warm and ice-rich permafrost regions.Based on ground temperature and deformation data of the embankment at location K1497+150 of the QTR in 2006-2018,the thermal regime and deformation process were analysed.The results showed that 1)the degradation rate of permafrost under the embankment was faster than that under the natural site without engineering construction,and 2)the deformation rate of the embankment had exceeded the safety range for the QTR embankment before adopting mitigative measures.In addition,this study evaluated the cooling effect on the underlying permafrost and working mechanism of two strengthening measures.Two measures,crushed rock revetment(CRR)and thermosyphons,were adopted to protect the underlying permafrost from continual degradation.The individual cooling effect of the CRR was not as good as that of the thermosyphons.However,the combination of the two could enhance the protective effects of each on the underlying permafrost,effectively cooling the permafrost and improving the stability of the embankment.展开更多
An experimental study was performed to evaluate the suitability of using an electrical capacitance tomography (ECT) system to visualize the flow patterns, and to measure the film thickness of the annular flow in a two...An experimental study was performed to evaluate the suitability of using an electrical capacitance tomography (ECT) system to visualize the flow patterns, and to measure the film thickness of the annular flow in a two-phase closed thermosyphon (TPCT). The performance of the ECT system was examined over a range of flow conditions.The experimental data were compared with the visual observations and existing correlations. Results indicated that the ECT system, with the linear back projection (LBP) algorithm, could be used to give an on-line qualitative image of the flow patterns. The Landweber iteration algorithm with optimal step length was implemented off-line to reconstruct high-resolution images. Then, the images were analyzed to obtain the film thickness of the annular flow. The experimental data compared well with the Nusselt's equation in low vapor velocity range, but showed an increasing deficiency with the increase of vapor velocity.展开更多
Critically filled thermosyphons for heat transport differ in size and temperature distribution from critically filled testcells for property research. Consequently, the thermodynamic states within a thermosyphon are...Critically filled thermosyphons for heat transport differ in size and temperature distribution from critically filled testcells for property research. Consequently, the thermodynamic states within a thermosyphon are distributed more heterogeneously. In a glass thermosyphon, flows and phase distributions were observed. A break down of the heat transport mechanism was found as a consequence of flooding the cooling region with liquid. Observed and explained-by use of a density/pressure diagram-were the effects of heating, of pressure and of fluid quantity on the distribution of the phases, the appearance of pulsations and the propagation of a heat pulse near the critical state.展开更多
The heat transfer perfonmance of a vertical two-phase closed thermosyphon(TPCT)used in a geothermal heat pump was experimentally investigated.The TPCT is a verticalplain steel pipe with inner diameter of 114 mm and bo...The heat transfer perfonmance of a vertical two-phase closed thermosyphon(TPCT)used in a geothermal heat pump was experimentally investigated.The TPCT is a verticalplain steel pipe with inner diameter of 114 mm and bored 368 m deep underground.Carbon dioxide(CO_(2))is used as working fluid.In the TPCT there is no condensation section.CO_(2)is condensed by the evaporator pf the heat pump,flows into the head of the TPCT and nuns down as a falling film along the inner wall of the pipe.For the heat transfer simulation in the TPCT,a quasi-dynamic model in which the mass transfer between the liquid and vapor phases as well as the conduction heat transfer from the surrounding soil towards the pipe is treated dynamically.However the film flow modeling is based on the Nusselt theory of frilm condenssation.The compauison of the experimental data with the numerical simulation is presented and discussed.展开更多
文摘Current practice of underground artificial ground freezing(AGF)typically involves huge refrigeration systems of large economic and environmental costs.In this study,a novel AGF technique is proposed deploying available cold wind in cold regions.This is achieved by a static heat transfer device called thermosyphon equipped with an air insulation layer.A refrigeration unit can be optionally integrated to meet additional cooling requirements.The introduction of air insulation isolates the thermosyphon from ground zones where freezing is not needed,resulting in:(1)steering the cooling resources(cold wind or refrigeration)towards zones of interest;and(2)minimizing refrigeration load.This design is demonstrated using well-validated mathematical models from our previous work based on two-phase enthalpy method of the ground coupled with a thermal resistance network for the thermosyphon.Two Canadian mines are considered:the Cigar Lake Mine and the Giant Mine.The results show that our proposed design can speed the freezing time by 30%at the Giant Mine and by two months at the Cigar Lake Mine.Further,a cooling load of 2.4 GWh can be saved at the Cigar Lake Mine.Overall,this study provides mining practitioners with sustainable solutions of underground AGF.
基金the National Natural Science Foundation of China(No.41971076No.42171128)the Heilongjiang Provincial Department of Science and Technology(GA21A501)。
文摘Two-phase closed thermosyphons(TPCTs)are widely used in infrastructure constructions in permafrost regions.Due to different climatic conditions,the effectiveness of TPCT will also be different,especially in the extremely cold region of the Da Xing'anling Mountains.In this study,a series of three-dimensional finite element TPCT embankment models were established based on the ZhanglingMohe highway TPCT test section in Da Xing'anling Mountains,and the thermal characteristics and the cooling effect of the TPCTs were analyzed.The results indicated that the TPCTs installed in the northeastern high-latitude regions is effective in cooling and stabilizing the embankment.The working cycle of the TPCTs is nearly 7 months,and the cooling range of the TPCTs can reach 3 m in this region.However,due to the extremely low temperature,the TPCT generates a large radial gradient in the permafrost layer.Meanwhile,by changing the climate conditions,the same type of TPCT embankment located in the Da Xing'anling Mountains,the Xiao Xing'anling Mountains,and the Qinghai-Tibet Plateau permafrost regions were simulated.Based on the comparison of the climate differences between the Qinghai-Tibet Plateau and Northeast China,the differences in the effectiveness of TPCTs were studied.Finally,the limitations of using existing TPCTs in high-latitude permafrost regions of China were discussed and the potential improvements of the TPCT in cold regions were presented.
基金supported by National Natural Science Foundation of China (Grant No.40730736 and No.40601023)the National Hi-Tech Research and Development Plan (2008AA11Z103)the Western Project Program of the Chinese Academy of Sciences (No.KZCX2-XB2-10)
文摘With the completion of the Qinghai-Tibetan Railway,economic development of related areas has been greatly accelerated.This,in return,calls for building or upgrading more roadways,especially high-grade roadways.In cold regions,the thawing of permafrost can induce settlement damage of and even failure to railway (or roadway) embankments.Thermosyphons (self-powered refrigera-tion devices that are used to help keep the permafrost cool) have proved effective in mitigating thaw settlement by maintaining the thermal stability of the embankments.However,for high-grade roadway embankments of great width,stabilizing or cooling ef-fects of traditional geotechnological measures may be limited.To enhance the cooling effect of thermosyphons,an L-shaped thermosyphon was designed.A laboratory test was carried out to study the combined cooling effect of the L-shaped thermosyphon and thermal insulation applying to roadbed construction.The angle between the evaporator and condenser sections of the L-shaped thermosyphon is 134 degrees,and the L-shaped thermosyphon was inserted into the soil at an angle of 5 degrees with the road surface.The tested results show that the L-shaped thermosyphon is effective in removing heat from a roadway in winter.When the ambient air temperature is lower than the soil temperature,the thermosyphon is active and extracts the heat in the soil around it.When the ambient air temperature is higher than the soil temperature,the thermosyphon is inactive,and no heat is in-jected into the soil through the L-shaped thermosyphon.Compared to embankments with straight thermosyphons,the inner parts of the embankments with L-shaped thermosyphons were significantly cooled.It is hoped that the present study would be useful to the application of L-shaped thermosyphons in the construction of high-grade roadways in cold regions.
文摘1 INTRODUCTIONClosed thermosyphon has been developed to enhance heat transfer and recover wasteheat in various process industries [1,2].Stimulated by this success,a new type oftwo-phase closed thermosyphon was designed by inserting respectively two inner tubesinto the thermosyphon,one in the boiling section and the other in the condensing sec-tion.The two-phase flow boiling heat transfer coefficient was calculated successfully onthe basis of Chen’s dual-mechanism [3].A boiling heat transfer model for thetwo-phase closed thermosyphon with an inner tube in the boiling section was pro-
文摘An experimental system was set up to measure the temperature, pressure, heat transfer rate and mass flow rate in a semi-open two-phase thermosyphon. The behaviors of a semi-open two-phase thermosyphon during startup, shutdown and lack of water were studied to get complete understanding of its thermal characteristics. The variation of wall temperature, heat-exchange condition and pressure fluctuations of semi-open two-phase thermosyphons showed that the startup of SOTPT needs about 60-70 min; the startup speed of SOTPT is determined by the startup speed of the condensation section; the average pressure in the heat pipe is equal to the environmental pressure usually; the shutdown of SOTPT needs about 30-50min; a semi-open two-phase thermosyphon has good response to lack of water accident.
基金supported by the Strategic Priority Research Program of Chinese Academy of Sciences (XDA20030201)National Natural Science Foundation of China (41672310)+1 种基金the National Key Research and Development Program (Nos. 2017YFC0405101 and 2016YFC0802103)the Research Project of the State Key Laboratory of Frozen Soil Engineering (SKLFSE-ZY-20)。
文摘The thaw settlement of pipeline foundation soils in response to the operation of the first China-Russia Crude Oil Pipeline along the eastern flank of the northern Da Xing'anling Mountains in Northeast China was simulated in a physical model test(with a similitude ratio of 1/73) in a geotechnical centrifuge. Two pipes of a supported and an unsupported section were evaluated over a testing period for simulating 20 years of actual pipeline operation with seasonal cyclically changing oil and ambient temperatures. The results show that pipe settlement of the supported pipe was 45% of settlement of the unsupported pipe. Settlement for the unsupported section was approximately 35% of the thaw bulb depth below the initial pipe elevation, only 30% of that for the supported pipe due to the influence of the supports. The final thaw bulbs extended approximately 3.6 and 1.6 times of the pipe diameter below the unsupported and supported pipe bottom elevations, respectively. The sandbag supports kept frozen during the test period because of cooling effect of the thermosyphons. The maximum bending stress induced over the 20 m span length from bearing of the full cover over the pipe would be equivalent to40% specified minimum yield strength(SMYS). Potential buckling of the pipe should be considered as the ground thaws.This study also offers important data for calibration and validation of numerical simulation models.
文摘A thermal model has been developed to study the thermal behavior of Thermosyphon integrated Heat Sink during CPU cooling. An Indirect cooling module has been experimentally studied and analyzed under steady state condition for both natural and forced convection. The thermal model is employed to determine the actual heat transfer and the effectiveness of the present model and compared it with the conventional cooling method and found that there is an appreciable improvement in the present model.
基金supported by the National Natural Science Fund(41571070)the Fund of SKLFS(SKLFSE-ZT-21)+2 种基金the Fund of the National Key Basic Research and Development Program(2012CB026102)the Funds of Key Research Program of Frontier Sciences of CAS(QYZDYSSWDQC015)fund HHS-TSS-STS-1502
文摘Snow covers the road embankments in winter in high latitude permafrost zones. The effect of snow cover on embankments was simulated based on field measurements of boundary conditions and initial ground temperature profile in Mohe,China. The effect of thermosyphons on the embankment warmed by snow cover was evaluated by numerical simulations as well. The results indicate that the difference of thermal regimes between non-thermosyphon and thermosyphon embankments reaches to 22 m in depth below the ground surface. It is much warmer in the non-thermosyphon embankment body in winter. Affected by the snow cover, heat flux gradually spreads into the deep ground of the subgrade over time. The permafrost table under the slope toe of a thermosyphon embankment is 1.2 m higher than that of a non-thermosyphon embankment in the 20 th year. In addition, the permafrost table at the slope toe of a thermosyphon embankment is 26 cm deeper over 20 years. These results indicate that thermosyphons can greatly weaken the warm effect of snow cover. However,thermosyphons cannot avoid the degradation of permafrost under the scenarios of snow cover. Therefore, composite measures need to be adopted to keep embankment stability in snowy permafrost zones.
基金the financial support from the National Natural Science Foundation of China (No. 50674096)PetroChina Scientific & Technological Risk Innovation Project (No. 060511-2-1)
文摘Compared with a conventional single section two-phase closed thermosyphon (TPCT) wellbore, a two-section TPCT wellbore has better heat transfer performance, which may improve the temperature distribution of fluid in wellbores, increase the temperature of fluid in wellheads and even more effectively reduce the failure rate of conventional TPCT wellbores. Heat transfer performance of two-section TPCT wellbores is affected by working medium, combination mode and oil flow rate. Different working media are introduced into the upper and lower TPCTs, which may achieve a better match between the working medium and the temperature field in the wellbores. Interdependence exists between the combination mode and the flow rate of the oil, which affects the heat transfer performance of a two-section TPCT wellbore. The experimental results show that a two-section TPCT wellbore, with equal upper and lower TPCTs respectively filled with Freon and methanol, has the best heat transfer performance when the oil flow rate is 200 L/h.
文摘With rapid development of the semiconductor technology, more efficient cooling systems for electronic devices are needed. In this situation, in the present study, a loop thermosyphon type cooling system, which is composed mainly of a heating block, an evaporator and an air-cooled condenser, is investigated experimentally in order to evaluate the cooling performance. At first, it is examined that the optimum volume filling rate of this cooling system is approximately 40%. Next, four kinds of working fluids, R1234ze(E), R1234ze(Z), R134a and ethanol, are tested using a blasted heat transfer surface of the evaporator. In cases of R1234ze(E), R1234ze(Z), R134a and ethanol, the effective heat flux, at which the heating block surface temperature reaches 70°C, is 116 W/cm2, 106 W/cm2, 104 W/cm2 and 60 W/cm2, respectively. This result indicates that R1234ze(E) is the most suitable for the present cooling system. The minimum boiling thermal resistance of R1234ze(E) is 0.05 (cm2·K)/W around the effective heat flux of 100 W/cm2. Finally, four kinds of heat transfer surfaces of the evaporator, smooth, blasted, copper-plated and finned surfaces, are tested using R1234ze(E) as working fluid. The boiling thermal resistance of the blasted surface is the smallest among tested heat transfer surfaces up to 116 W/cm2 in effective heat flux. However, it increases drastically due to the appearance of dry-patch if the effective heat flux exceeds 116 W/cm2. On the other hand, in cases of copper-plated and finned surfaces, the dry-patch does not appear up to 150 W/cm2 in effective heat flux, and the boiling thermal resistances of those surfaces keep 0.1 (cm2·K)/W.
文摘We have developed a loop thermosyphon for cooling electronic devices. The cooling performance of a thermosyphon deteriorates with an increasing amount of non-condensable gas (NCG). Design of a thermosyphon must consider NCG to provide guaranteed performance for a long time. In this study, the heat transfer performance of a thermosyphon was measured while changing the amount of NCG. The resultant performances were expressed as approximations. These approximations enabled us to predict the total thermal resistance of the thermosyphon by the amount of NCG and input heating. Then, using the known leakage in the thermosyphon and the amount of dissolved NCG in the water, we can predict the amount of NCG and the total thermal resistance of the thermosyphon after ten years. Although there is a slight leakage in the thermosyphon, we are able to design a thermosyphon with a guaranteed level of cooling performance for a long time using the proposed design method.
文摘Heat transfer and hydrodynamics of two phase closed thermosyphon (TPCT) is studied using finite difference method of Stream function and vorticity. The mathematical model is formed for both vapor phase and liquid film in a non-dimensional form. The momentum and energy equations as parabolic equations have been solved by means of the locally one-dimensional scheme of A.A. Samarskii. The Poisson equation for the stream function has been approximated on the basis of the discrete scheme "cross". The obtained system of algebraic equations has been solved by the successive over relaxation method. The effect of the Rayleigh number on the velocity and temperature fields in the domain of interest and on the average Nusselt number at the solid-fluid interfaces is investigated. It was found that increase in the Rayleigh number leads to the increment of both the average Nusselt number and the stream function in the vapor zone.
文摘The heat losses density in power electronics products follows an ever increasing trend. Nowadays they reach 200 W/cmz at chip level and 50 W/cm2 at heatsink base level. Water cooling is the most effective cooling method but unfortunately water is often undesired due to high voltages or costumer requirements. Two-phase cooling is a promising technology for electronics cooling. It allows using dielectric fluids in passive systems and still benefits from very high heat transfer coefficients. Thermosyphons are a particularly interesting technology in the field of power electronics because it is entirely passive and a simple equipment. ABB has developed a compact thermosyphon heat exchanger based on automotive technology, which uses numerous multi-port extruded tubes with capillary sized channels disposed in parallel and brazed to a heated base plate in order to achieve the desired compactness. The experimental performances of this novel power electronics cooling system are presented with R134a as a working fluid. The influence of several parameters on the performances was studied experimentally: coolant flow rate, coolant temperature, heat load and fluid filling.
基金This research was supported by the Second Tibetan Plateau Scientific Expedition and Research Program(STEP)(2021QZKK0205)the National Natural Science Foundation of China(41901082).
文摘To ensure the long-term service performance of infrastructure such as railways,highways,airports and oil pipelines built on permafrost slope wetland sites,it is imperative to systematically uncover the long-term heat-water changes of soil in slope wetlands environment under climate warming.More specifically,considering valuable field data from 2001 to 2019,the long-term heat and water changes in active layers of the slope wetland site along the Qinghai-Xizang Railway(QXR)are illustrated,the effect of thermosyphon measures in protecting the permafrost environment is evaluated,and the influences of climate warming and hydrological effects on the stability of slope wetland embankments are systematically discussed.The permafrost at the slope wetland site is rapidly degrading,demonstrating a reduction in active layer thickness of>3.7 cm per year and a permafrost temperature warming of>0.006℃ per year.The thermosiphon embankment developed by QXR has a specific cooling period;thus,to mitigate the long-term impacts of climate warming on the thermal stability of permafrost foundation,it is essential to implement strengthening measures for the thermosiphon embankment,such as adding a crushed-rock layer or sunshade board on the slope of thermosiphon embankment to creating a composite cooling embankment.Short-term seasonal groundwater seepage intensifies frost damage to the slope wetland embankment,while long-term seasonal supra-permafrost water and groundwater seepage exacerbates uneven transverse deformation of slope wetland embankment.Long-term climate warming and slope effects have altered the surface water and groundwater hydrological processes of slope wetlands,potentially leading to an increased occurrence of slope embankment instability.These results are crucial for improving our understanding of heat and water variation processes in the active layer of slope wetland sites located in permafrost regions and ensuring long-term service safety for the QXR.
基金funded by the Second Tibetan Plateau Scientific Expedition and Research Program (STEP) (2021QZKK0205 and 2021QZKK0201)the Research Project of the State Key Laboratory of Frozen Soil Engineering (SKLFSE202101).
文摘Over the years,numerous geotechnical approaches have been implemented to mitigate the adverse effects of climate warming on various infrastructures in the permafrost region of the Qinghai-Tibet Plateau(QTP),such as the Qinghai-Tibet Highway and Railway,and achieved the expected engineering outcomes.However,little attention has been given to whether the performance of these geotechnical approaches has changed during the ongoing process of climate warming.To investigate the performance variation of one of these geotechnical approaches,which is two-phase closed thermosyphon(TPCT),during sustained climate warming,we conducted a statistical analysis of soil temperature monitoring data in 2003-2020 from eight regular embankments and six TPCT embankments in our permafrost monitoring network.The results indicate that TPCT undeniably has a cooling effect on the permafrost beneath embankments,even rapidly eliminated previously formed taliks beneath embankment.However,further analysis reveals that the performance of TPCT has been weakening during sustained climate warming,which has confirmed by the re-forming of the taliks beneath embankment where they had been previously eliminated.Based on the current understanding,we attributed the weakening of thermosyphon performance to a significant reduction in the air temperature freezing index caused by ongoing climate warming.Through this study,we aimed to draw attention to the evolving performance of geotechnical approaches in permafrost regions amid climate warming,prompting necessary engineering innovations to address this situation and ensure the sustainable development of the permafrost region on the QTP.
文摘Experiments were conducted in this study to examine the thermal performance of a thermosyphon,made from Inconel alloy 625,could recover waste heat from automobile exhaust using a limited amount of fluid.The thermosyphon has an outer diameter of 27 mm,a thickness of 2.6 mm,and an overall length of 483 mm.The study involved directing exhaust gas onto the evaporator.This length includes a 180-mm evaporator,a 70-mm adiabatic section,a 223-mm condenser,and a 97-mm finned exchanger.The study examined the thermal performance of the thermosyphon under exhaust flow rates ranging from 0–10 g/sec and temperatures varying from 300℃–900℃.The influence of three parameters—inclination angle(5°–45°),water mass(2–5.3 g),and the quantity of non-condensable gas Argon(0–0.6 g)—was investigated to assess their impacts on the thermosyphon’s thermal efficiency.The experimental findings revealed that with 3 g of water and 0.0564 g of argon in the thermosyphon,the condenser reached its highest temperature at around 200℃.The ideal fuel loading rate for the thermosyphon falls between 0.2 and 0.7 g/s.Moreover,as inclination angles rise,outer wall temperatures of the thermosyphon increase.This is attributed to the explicit expansion of the effective heating area within the evaporation section,coupled with an amplified gravitational component of the water flux.Additionally,an upsurge in the quantity of non-condensable gas(NCG)can mitigate temperature gradients on the outer wall,resulting in a decline in the thermosyphon’s performance.The insulation applied to the adiabatic section demonstrated efficacy in augmenting temperature gradients on the outer wall,thereby improving the overall performance of the thermosyphon.As the water charge within the thermosyphon increases,there is a corresponding rise in heat transfer rates both from the exhaust to the thermosyphon and from the thermosyphon to the fuel.
基金supported by the Strategic Priority Research Program of the Chinese Academy of Science(XDA20020102)Science and Technology Project of State Grid Corporation of China(SGQHDKYOSBJS201600077)+1 种基金the Natural Science Foundation of China(41101065)the State Key Laboratory of Frozen Soils Engineering Foundation(SKLFSE-ZT-34).
文摘The embankment of the Qinghai-Tibet Railway(QTR)has been experiencing severe problems due to permafrost degradation,especially in warm and ice-rich permafrost regions.Based on ground temperature and deformation data of the embankment at location K1497+150 of the QTR in 2006-2018,the thermal regime and deformation process were analysed.The results showed that 1)the degradation rate of permafrost under the embankment was faster than that under the natural site without engineering construction,and 2)the deformation rate of the embankment had exceeded the safety range for the QTR embankment before adopting mitigative measures.In addition,this study evaluated the cooling effect on the underlying permafrost and working mechanism of two strengthening measures.Two measures,crushed rock revetment(CRR)and thermosyphons,were adopted to protect the underlying permafrost from continual degradation.The individual cooling effect of the CRR was not as good as that of the thermosyphons.However,the combination of the two could enhance the protective effects of each on the underlying permafrost,effectively cooling the permafrost and improving the stability of the embankment.
文摘An experimental study was performed to evaluate the suitability of using an electrical capacitance tomography (ECT) system to visualize the flow patterns, and to measure the film thickness of the annular flow in a two-phase closed thermosyphon (TPCT). The performance of the ECT system was examined over a range of flow conditions.The experimental data were compared with the visual observations and existing correlations. Results indicated that the ECT system, with the linear back projection (LBP) algorithm, could be used to give an on-line qualitative image of the flow patterns. The Landweber iteration algorithm with optimal step length was implemented off-line to reconstruct high-resolution images. Then, the images were analyzed to obtain the film thickness of the annular flow. The experimental data compared well with the Nusselt's equation in low vapor velocity range, but showed an increasing deficiency with the increase of vapor velocity.
文摘Critically filled thermosyphons for heat transport differ in size and temperature distribution from critically filled testcells for property research. Consequently, the thermodynamic states within a thermosyphon are distributed more heterogeneously. In a glass thermosyphon, flows and phase distributions were observed. A break down of the heat transport mechanism was found as a consequence of flooding the cooling region with liquid. Observed and explained-by use of a density/pressure diagram-were the effects of heating, of pressure and of fluid quantity on the distribution of the phases, the appearance of pulsations and the propagation of a heat pulse near the critical state.
基金The present research work was supported by the Federal Ministry for Economic Affairs and Energy of Germanyunder the funding code FKZ:03ET1050B.
文摘The heat transfer perfonmance of a vertical two-phase closed thermosyphon(TPCT)used in a geothermal heat pump was experimentally investigated.The TPCT is a verticalplain steel pipe with inner diameter of 114 mm and bored 368 m deep underground.Carbon dioxide(CO_(2))is used as working fluid.In the TPCT there is no condensation section.CO_(2)is condensed by the evaporator pf the heat pump,flows into the head of the TPCT and nuns down as a falling film along the inner wall of the pipe.For the heat transfer simulation in the TPCT,a quasi-dynamic model in which the mass transfer between the liquid and vapor phases as well as the conduction heat transfer from the surrounding soil towards the pipe is treated dynamically.However the film flow modeling is based on the Nusselt theory of frilm condenssation.The compauison of the experimental data with the numerical simulation is presented and discussed.