期刊文献+
共找到121,597篇文章
< 1 2 250 >
每页显示 20 50 100
A Yb optical clock with a lattice power enhancement cavity
1
作者 王春云 姚远 +3 位作者 师浩森 于洪浮 马龙生 蒋燕义 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期70-74,共5页
We construct a power enhancement cavity to form an optical lattice in an ytterbium optical clock.It is demonstrated that the intra-cavity lattice power can be increased by about 45 times,and the trap depth can be as l... We construct a power enhancement cavity to form an optical lattice in an ytterbium optical clock.It is demonstrated that the intra-cavity lattice power can be increased by about 45 times,and the trap depth can be as large as 1400Er when laser light with a power of only 0.6 W incident to the lattice cavity.Such high trap depths are the key to accurate evaluation of the lattice-induced light shift with an uncertainty down to~1×10-18.By probing the ytterbium atoms trapped in the power-enhanced optical lattice,we obtain a 4.3 Hz-linewidth Rabi spectrum,which is then used to feedback to the clock laser for the close loop operation of the optical lattice clock.We evaluate the density shift of the Yb optical lattice clock based on interleaving measurements,which is-0.46(62)mHz.This result is smaller compared to the density shift of our first Yb optical clock without lattice power enhancement cavity mainly due to a larger lattice diameter of 344μm. 展开更多
关键词 optical atomic clock optical lattice optical cavity Stark shift
下载PDF
Automated evaluation of parapapillary choroidal microvasculature in crowded optic discs:a controlled,optical coherence tomography angiography study
2
作者 Hatice Arda Hidayet Sener +5 位作者 Ozge Temizyurek Hatice Kubra Sonmez Duygu Gulmez Sevim Cem Evereklioglu Fatih Horozoglu Ayse Busra Gunay Sener 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第1期113-118,共6页
AIM:To compare superficial and deep vascular properties of optic discs between crowded discs and controls using optical coherence tomography angiography(OCT-A).METHODS:Thirty patients with crowded discs,and 47 control... AIM:To compare superficial and deep vascular properties of optic discs between crowded discs and controls using optical coherence tomography angiography(OCT-A).METHODS:Thirty patients with crowded discs,and 47 control subjects were enrolled in the study.One eye of each individual was included and OCT-A scans of optic discs were obtained in a 4.5×4.5 mm^(2) rectangular area.Radial peripapillary capillary(RPC)density,peripapillary retinal nerve fiber layer(pRNFL)thickness,cup volume,rim area,disc area,cup-to-disc(c/d)area ratio,and vertical c/d ratio were obtained automatically using device software.Automated parapapillary choroidal microvasculature(PPCMv)density was calculated using MATLAB software.When the vertical c/d ratio of the optic disc was absent or small cup,it was considered as a crowded disc.RESULTS:The mean signal strength index of OCT-A images was similar between the crowded discs and control eyes(P=0.740).There was no difference in pRNFL between the two groups(P=0.102).There were no differences in RPC density in whole image(P=0.826)and peripapillary region(P=0.923),but inside disc RPC density was higher in crowded optic discs(P=0.003).The PPCMv density in the inner-hemisuperior region was also lower in crowded discs(P=0.026).The pRNFL thickness was positively correlated with peripapillary RPC density(r=0.498,P<0.001).The inside disc RPC density was negatively correlated with c/d area ratio(r=-0.341,P=0.002).CONCLUSION:The higher inside disc RPC density and lower inner-hemisuperior PPCMv density are found in eyes with crowded optic discs. 展开更多
关键词 crowded optic disc ischemic optic neuropathy optical coherence tomography angiography parapapillary choroidal microvasculature
下载PDF
Breaking the optical efficiency limit of virtual reality with a nonreciprocal polarization rotator
3
作者 Yuqiang Ding Zhenyi Luo +1 位作者 Garimagai Borjigin Shin-Tson Wu 《Opto-Electronic Advances》 SCIE EI CAS CSCD 2024年第3期4-14,共11页
A catadioptric lens structure,also known as pancake lens,has been widely used in virtual reality(VR)displays to reduce the formfactor.However,the utilization of a half mirror(HM)to fold the optical path thrice leads t... A catadioptric lens structure,also known as pancake lens,has been widely used in virtual reality(VR)displays to reduce the formfactor.However,the utilization of a half mirror(HM)to fold the optical path thrice leads to a significant optical loss.The theoretical maximum optical efficiency is merely 25%.To transcend this optical efficiency constraint while retaining the foldable characteristic inherent to traditional pancake optics,in this paper,we propose a theoretically lossless folded optical system to replace the HM with a nonreciprocal polarization rotator.In our feasibility demonstration experiment,we used a commercial Faraday rotator(FR)and reflective polarizers to replace the lossy HM.The theoretically predicted 100%efficiency can be achieved approximately by using two high-extinction-ratio reflective polarizers.In addition,we evaluated the ghost images using a micro-OLED panel in our imaging system.Indeed,the ghost images can be suppressed to undetectable level if the optics are with antireflection coating.Our novel pancake optical system holds great potential for revolutionizing next-generation VR displays with lightweight,compact formfactor,and low power consumption. 展开更多
关键词 near-eye display virtual reality pancake optics folded optics nonreciprocal polarization rotator
下载PDF
Predictive visual field outcomes after optic chiasm decompressive surgery by retinal vessels parameters using optical coherence tomography angiography
4
作者 Wen-Juan Yu Jin Xiao +3 位作者 Guang-Xin Wang Chang Jiang Wei Zha Rong-Feng Liao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期365-373,共9页
AIM:To evaluate the predictive value of superficial retinal capillary plexus(SRCP)and radial peripapillary capillary(RPC)for visual field recovery after optic cross decompression and compare them with peripapillary ne... AIM:To evaluate the predictive value of superficial retinal capillary plexus(SRCP)and radial peripapillary capillary(RPC)for visual field recovery after optic cross decompression and compare them with peripapillary nerve fiber layer(pRNFL)and ganglion cell complex(GCC).METHODS:This prospective longitudinal observational study included patients with chiasmal compression due to sellar region mass scheduled for decompressive surgery.Generalized estimating equations were used to compare retinal vessel density and retinal layer thickness preand post-operatively and with healthy controls.Logistic regression models were used to assess the relationship between preoperative GCC,pRNFL,SRCP,and RPC parameters and visual field recovery after surgery.RESULTS:The study included 43 eyes of 24 patients and 48 eyes of 24 healthy controls.Preoperative RPC and SRCP vessel density and pRNFL and GCC thickness were lower than healthy controls and higher than postoperative values.The best predictive GCC and pRNFL models were based on the superior GCC[area under the curve(AUC)=0.866]and the tempo-inferior pRNFL(AUC=0.824),and the best predictive SRCP and RPC models were based on the nasal SRCP(AUC=0.718)and tempo-inferior RPC(AUC=0.825).There was no statistical difference in the predictive value of the superior GCC,tempo-inferior pRNFL,and tempo-inferior RPC(all P>0.05).CONCLUSION:Compression of the optic chiasm by tumors in the saddle area can reduce retinal thickness and blood perfusion.This reduction persists despite the recovery of the visual field after decompression surgery.GCC,pRNFL,and RPC can be used as sensitive predictors of visual field recovery after decompression surgery. 展开更多
关键词 sellar region mass retinal vessels optic chiasm optical coherence tomography angiography visual field decompressive surgery
下载PDF
Using Optical Tweezers to Study the Friction of the Red Blood Cells
5
作者 Edoukoua Jean Michel Konin Pavel Yale +3 位作者 Abadê Ange-Boris N’guessan Kouassi Benoit Kouakou Abaka Michel Kouacou Eugene Megnassan 《Advances in Bioscience and Biotechnology》 CAS 2024年第2期100-111,共12页
In the last two decades the study of red blood cell elasticity using optical tweezers has known a rise appearing in the scientific research with regard to the various works carried out. Despite the various work done, ... In the last two decades the study of red blood cell elasticity using optical tweezers has known a rise appearing in the scientific research with regard to the various works carried out. Despite the various work done, no study has been done so far to study the influence of friction on the red blood cell indentation response using optical tweezers. In this study, we have developed a new approach to determine the coefficient of friction as well as the frictional forces of the red blood cell. This approach therefore allowed us to simultaneously carry out the indentation and traction test, which allowed us to extract the interfacial properties of the microbead red blood cell couple, among other things, the friction coefficient. This property would be extremely important to investigate the survival and mechanical features of cells, which will be of great physiological and pathological significance. But taking into account the hypothesis of friction as defined by the isotropic Coulomb law. The experiment performed for this purpose is the Brinell Hardness Test (DB). 展开更多
关键词 FRICTION INDENTATION optical Tweezers TRIBOLOGY Red Blood Cells
下载PDF
Exciton-polaritons in a 2D hybrid organic-inorganic perovskite microcavity with the presence of optical Stark effect
6
作者 Kenneth Coker 郑楚媛 +2 位作者 Joseph Roger Arhin Kwame Opuni-Boachie Obour Agyekum 张伟利 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期551-555,共5页
This study investigates the properties of exciton-polaritons in a two-dimensional(2D)hybrid organic-inorganic perovskite microcavity in the presence of optical Stark effect.Through both steady and dynamic state analys... This study investigates the properties of exciton-polaritons in a two-dimensional(2D)hybrid organic-inorganic perovskite microcavity in the presence of optical Stark effect.Through both steady and dynamic state analyses,strong coupling between excitons of perovskite and cavity photons is revealed,indicating the formation of polaritons in the perovskite microcavity.Besides,it is found that an external optical Stark pulse can induce energy shifts of excitons proportional to the pulse intensity,which modifies the dispersion characteristics of the polaritons. 展开更多
关键词 EXCITON-POLARITONS PEROVSKITE MICROCAVITY optical Stark effect
下载PDF
Using harmonic beam combining to generate pulse-burst in nonlinear optical laser
7
作者 许元斋 李珍玲 +5 位作者 张奥楠 刘可 张晶晶 王小军 彭钦军 许祖彦 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期422-427,共6页
The ultrashort lasers working in pulse-burst mode reveal great machining performance in recent years. The number of pulses in bursts effects greatly on the removal rate and roughness. To generate a more equal amplitud... The ultrashort lasers working in pulse-burst mode reveal great machining performance in recent years. The number of pulses in bursts effects greatly on the removal rate and roughness. To generate a more equal amplitude of pulses in burst with linear polarization output and time gap adjustable, we propose a new method by the harmonic beam combining(HBC).The beam combining is commonly used in adding pulses into the output beam while maintaining the pulse waveform and beam quality. In the HBC, dichroic mirrors are used to combine laser pulses of fundamental wave(FW) into harmonic wave(HW), and nonlinear crystals are used to convert the FW into HW. Therefore, HBC can add arbitrarily more HW pulses to generate pulse-burst in linear polarization with simple structure. The amplitude of each pulse in bursts can be adjusted the same to increase the stability of the burst, the time gap of each pulse can be adjusted precisely by proper time delay. Because HBC adds pulses sequentially, the peak power density of the burst is the same as each pulse, pulses can be combined without concern of back-conversion which often occurs in high peak power density. In the demonstration, the extendibility of HBC was verified by combining two beams with a third beam. The combined efficiency rates were larger than 99%, and the beam quality of each beam was maintained at M^(2)≈1.4. 展开更多
关键词 pulse-burst beam combining nonlinear optics
下载PDF
Aflibercept combined with triamcinolone acetonide in the treatment of diabetic macular edema:optical coherence tomography and optical coherence tomography angiography
8
作者 De-Shuang Li Hong-Xia Liao +4 位作者 Chuan-He Zhang Jian-Guo Huang Wei Chen Jing-Lin Zhang Bo Qin 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期670-675,共6页
AIM:To analyze the relationship between optical coherence tomography(OCT)and OCT angiography(OCTA)imaging in patients with diabetic macular edema(DME)who are treated with a combination of aflibercept and triamcinolone... AIM:To analyze the relationship between optical coherence tomography(OCT)and OCT angiography(OCTA)imaging in patients with diabetic macular edema(DME)who are treated with a combination of aflibercept and triamcinolone acetonide(TA).METHODS:A total of 76 eyes newly diagnosed DME were included in this study.They were randomly assigned to receive either aflibercept or a combination of aflibercept and TA.Injections once a month for a total of three injections.Central macular thickness(CMT),number of hyperreflective foci(HRF),height of subretinal fluid(SRF),and area of foveal avascular zone(FAZ)were evaluated using OCT and OCTA at baseline and after each monthly treatment.RESULTS:Both groups showed improvement in best corrected visual acuity(BCVA)and reduction in macular edema after treatment,and the difference in BCVA between the two groups was statistically significant after each treatment(P<0.05).The difference in CMT between the two groups was statistically significant after the first two injections(P<0.01),but not after the third injection(P=0.875).The number of HRF(1mo:7.41±8.25 vs 10.86±7.22,P=0.027;2mo:5.33±6.13 vs 9.12±8.61,P=0.034;3mo:3.58±3.00 vs 6.37±5.97,P=0.007)and height of SRF(1mo:82.39±39.12 vs 105.77±42.26μm,P=0.011;2mo:36.84±10.02 vs 83.59±37.78μm,P<0.01;3mo:11.57±3.29 vs 45.43±12.60μm,P<0.01)in combined group were statistically significant less than aflibercept group after each injection,while the area of FAZ showed no significant change before and after treatment in both groups.CONCLUSION:The combination therapy of aflibercept and TA shows more significant effects on DME eyes with decreased HRF and SRF.However,both aflibercept and combination therapy show no significant change in the area of FAZ. 展开更多
关键词 diabetic macular edema optical coherence tomography optical coherence tomography angiography hyperreflective foci subretinal fluid foveal avascular zone AFLIBERCEPT
下载PDF
Development of D_α band symmetrical visible optical diagnostic for boundary reconstruction on EAST tokamak
9
作者 陈明 沈飊 +4 位作者 Shinichiro KADO 郭笔豪 陈大龙 蔡福瑞 肖炳甲 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第2期44-53,共10页
To investigate the potential of utilizing visible spectral imaging for controlling the plasma boundary shape during stable operation of plasma in future tokamak, a D_α band symmetric visible light diagnostic system w... To investigate the potential of utilizing visible spectral imaging for controlling the plasma boundary shape during stable operation of plasma in future tokamak, a D_α band symmetric visible light diagnostic system was designed and implemented on the Experimental Advanced Superconducting Tokamak(EAST). This system leverages two symmetric optics for joint plasma imaging. The optical system exhibits a spatial resolution less than 2 mm at the poloidal cross-section, distortion within the field of view below 10%, and relative illumination of 91%.The high-quality images obtained enable clear observation of both the plasma boundary position and the characteristics of components within the vacuum vessel. Following system calibration and coordinate transformation, the image coordinate boundary features are mapped to the tokamak coordinate system. Utilizing this system, the plasma boundary was reconstructed, and the resulting representation showed alignment with the EFIT(Equilibrium Fitting) results. This underscores the system's superior performance in boundary reconstruction applications and provides a diagnostic foundation for boundary shape control based on visible spectral imaging. 展开更多
关键词 visible optical diagnostic plasma boundary reconstruction EAST
下载PDF
A dual-route optical emission spectroscopy diagnostic with wide spectral range and high wavelength resolution on HL-2A tokamak
10
作者 陈越 高继昆 +10 位作者 龙婷 聂林 高金明 马尧 黄渊 田文静 刘延民 朱晓东 庄革 钟武律 许敏 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期25-30,共6页
A dual-route optical emission spectroscopy(D-OES)diagnostic is newly developed to monitor the optical emission from the X-point plasma region on the HL-2 A tokamak.This diagnostic is composed of an imaging system,a be... A dual-route optical emission spectroscopy(D-OES)diagnostic is newly developed to monitor the optical emission from the X-point plasma region on the HL-2 A tokamak.This diagnostic is composed of an imaging system,a beam-splitting system for dual-route measurements,fiber bundles,a spectrometer system,and a control and acquisition system.One route is used to obtain wide-spectral-range spectra,and the other route is used to acquire high-wavelengthresolution line shapes.The spectral resolution of the wide-range spectrometers is 0.8 nm with a coverage of 800 nm(@200-1000 nm).The spectral resolution of the high-resolution spectrometer is 0.01 nm with a coverage of 6 nm(@200-660 nm).The spatial resolution of each route of D-OES is about 4 cm with 11 channels.The temporal resolution is 16 ms at maximum in the single-channel mode.Wide-range spectra(containing Balmer series and a Fulcher band)and highly resolved Ha line shapes are obtained by D-OES in the hydrogen glow discharge in the lab.D-OES measurements are carried out in the high-density deuterium experiments of HL-2A.The electron density n_(e)and deuterium temperature T_(D) in the X-point multifaceted asymmetric radiation from the edge(MARFE)region are derived simultaneously by fitting the measured D_(a) shape.The density n_(e)is observed to increase from~8.7×10^(18)m^(-3)to~7.8×10^(19)m^(-3),and the temperature T_(D)drops from~14.4 eV to~2.3 eV after the onset of MARFE in the discharge#38260. 展开更多
关键词 optical emission spectroscopy Balmer series TOKAMAK
下载PDF
Robust free-space optical frequency transfer in time-varying link distances conditions
11
作者 童周 刘雷 +6 位作者 王家亮 操前 金志成 应康 韩申生 韩正甫 桂有珍 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期271-276,共6页
Future inter-satellite clock comparison on high orbit will require optical time and frequency transmission technology between moving objects.Here,we demonstrate robust optical frequency transmission under the conditio... Future inter-satellite clock comparison on high orbit will require optical time and frequency transmission technology between moving objects.Here,we demonstrate robust optical frequency transmission under the condition of variable link distance.This variable link is accomplished by the relative motion of a single telescope fixed on the experimental platform to a corner-cube reflector(CCR)installed on a sliding guide.Two acousto–optic modulators with different frequencies are used to separate forward signal from backward signal.With active phase noise suppression,when the CCR moves back and forth at a constant velocity of 20 cm/s and an acceleration of 20 cm/s^(2),we achieve the best frequency stability of 1.9×10^(-16) at 1 s and 7.9×10^(-19) at 1000 s indoors.This work paves the way for future studying optical frequency transfer between ultra-high-orbit satellites. 展开更多
关键词 FREE-SPACE optical frequency transfer variable link distance
下载PDF
Gates joint locally connected network for accurate and robust reconstruction in optical molecular tomography
12
作者 Minghua Zhao Yahui Xiao +2 位作者 Jiaqi Zhang Xin Cao Lin Wang 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期11-22,共12页
Optical molecular tomography(OMT)is a potential pre-clinical molecular imaging technique with applications in a variety of biomedical areas,which can provide non-invasive quantitative three-dimensional(3D)information ... Optical molecular tomography(OMT)is a potential pre-clinical molecular imaging technique with applications in a variety of biomedical areas,which can provide non-invasive quantitative three-dimensional(3D)information regarding tumor distribution in living animals.The construction of optical transmission models and the application of reconstruction algorithms in traditional model-based reconstruction processes have affected the reconstruction results,resulting in problems such as low accuracy,poor robustness,and long-time consumption.Here,a gates joint locally connected network(GLCN)method is proposed by establishing the mapping relationship between the inside source distribution and the photon density on surface directly,thus avoiding the extra time consumption caused by iteration and the reconstruction errors caused by model inaccuracy.Moreover,gates module was composed of the concatenation and multiplication operators of three different gates.It was embedded into the network aiming at remembering input surface photon density over a period and allowing the network to capture neurons connected to the true source selectively by controlling three different gates.To evaluate the performance of the proposed method,numerical simulations were conducted,whose results demonstrated good performance in terms of reconstruction positioning accuracy and robustness. 展开更多
关键词 optical molecular tomography gates module positioning accuracy ROBUSTNESS
下载PDF
Gigahertz frequency hopping in an optical phase-locked loop for Raman lasers
13
作者 毛德凯 税鸿冕 +3 位作者 殷国玲 彭鹏 王春唯 周小计 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期60-65,共6页
Raman lasers are essential in atomic physics,and the development of portable devices has posed requirements for time-division multiplexing of Raman lasers.We demonstrate an innovative gigahertz frequency hopping appro... Raman lasers are essential in atomic physics,and the development of portable devices has posed requirements for time-division multiplexing of Raman lasers.We demonstrate an innovative gigahertz frequency hopping approach of a slave Raman laser within an optical phase-locked loop(OPLL),which finds practical application in an atomic gravimeter,where the OPLL frequently switches between near-resonance lasers and significantly detuned Raman lasers.The method merges the advantages of rapid and extensive frequency hopping with the OPLL’s inherent low phase noise,and exhibits a versatile range of applications in compact laser systems,promising advancements in portable instruments. 展开更多
关键词 Raman lasers optical phase-locked loop frequency hopping
下载PDF
Distal-scanning common path probe for optical coherence tomography
14
作者 Zhengyu Chen Bin He +8 位作者 Zichen Yin Zhangwei Hu Yejiong Shi Chengming Wang Xiao Zhang Ning Zhang Linkai Jing Guihuai Wang Ping Xue 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期84-92,共9页
In this paper,we present a distal-scanning common path probe for optical coherence tomography(OCT)equipped with a hollow ultrasonic motor and a simple and specially designed beam-splitter.This novel probe proves to be... In this paper,we present a distal-scanning common path probe for optical coherence tomography(OCT)equipped with a hollow ultrasonic motor and a simple and specially designed beam-splitter.This novel probe proves to be able to effectively circumvent polarization and dispersion mismatch caused by fiber motion and is more robust to a variety of interfering factors during the imaging process,experimentally compared to a conventional noncommon path probe.Furthermore,our design counteracts the attenuation of backscattering with depth and the fall-off of the signal,resulting in a more balanced signal range and greater imaging depth.Spectral-domain OCT imaging of phantom and biological tissue is also demonstrated with a sensitivity of∼100dB and a lateral resolution of∼3μm.This low-cost probe offers simplified system configuration and excellent robustness,and is therefore particularly suitable for clinical diagnosis as one-off medical apparatus. 展开更多
关键词 Common path optical coherence tomography endoscopic probe
下载PDF
Finesse measurement for high-power optical enhancement cavity
15
作者 陆心怡 柳兴 +3 位作者 田其立 王焕 汪嘉俊 颜立新 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期414-421,共8页
Finesse is a critical parameter for describing the characteristics of an optical enhancement cavity(OEC). This paper first presents a review of finesse measurement techniques, including a comparative analysis of the a... Finesse is a critical parameter for describing the characteristics of an optical enhancement cavity(OEC). This paper first presents a review of finesse measurement techniques, including a comparative analysis of the advantages, disadvantages, and potential limitations of several main methods from both theoretical and practical perspectives. A variant of the existing method called the free spectral range(FSR) modulation method is proposed and compared with three other finesse measurement methods, i.e., the fast-switching cavity ring-down(CRD) method, the rapidly swept-frequency(SF) CRD method, and the ringing effect method. A high-power OEC platform with a high finesse of approximately 16000 is built and measured with the four methods. The performance of these methods is compared, and the results show that the FSR modulation method and the fast-switching CRD method are more suitable and accurate than the other two methods for high-finesse OEC measurements. The CRD method and the ringing effect method can be implemented in open loop using simple equipment and are easy to perform. Additionally, recommendations for selecting finesse measurement methods under different conditions are proposed, which benefit the development of OEC and its applications. 展开更多
关键词 optical enhancement cavity finesse measurement cavity ring-down ringing effect
下载PDF
Optimizing Optical Fiber Faults Detection:A Comparative Analysis of Advanced Machine Learning Approaches
16
作者 Kamlesh Kumar Soothar Yuanxiang Chen +2 位作者 Arif Hussain Magsi Cong Hu Hussain Shah 《Computers, Materials & Continua》 SCIE EI 2024年第5期2697-2721,共25页
Efficient optical network management poses significant importance in backhaul and access network communicationfor preventing service disruptions and ensuring Quality of Service(QoS)satisfaction.The emerging faultsin o... Efficient optical network management poses significant importance in backhaul and access network communicationfor preventing service disruptions and ensuring Quality of Service(QoS)satisfaction.The emerging faultsin optical networks introduce challenges that can jeopardize the network with a variety of faults.The existingliterature witnessed various partial or inadequate solutions.On the other hand,Machine Learning(ML)hasrevolutionized as a promising technique for fault detection and prevention.Unlike traditional fault managementsystems,this research has three-fold contributions.First,this research leverages the ML and Deep Learning(DL)multi-classification system and evaluates their accuracy in detecting six distinct fault types,including fiber cut,fibereavesdropping,splicing,bad connector,bending,and PC connector.Secondly,this paper assesses the classificationdelay of each classification algorithm.Finally,this work proposes a fiber optics fault prevention algorithm thatdetermines to mitigate the faults accordingly.This work utilized a publicly available fiber optics dataset namedOTDR_Data and applied different ML classifiers,such as Gaussian Naive Bayes(GNB),Logistic Regression(LR),Support Vector Machine(SVM),K-Nearest Neighbor(KNN),Random Forest(RF),and Decision Tree(DT).Moreover,Ensemble Learning(EL)techniques are applied to evaluate the accuracy of various classifiers.In addition,this work evaluated the performance of DL-based Convolutional Neural Network and Long-Short Term Memory(CNN-LSTM)hybrid classifier.The findings reveal that the CNN-LSTM hybrid technique achieved the highestaccuracy of 99%with a delay of 360 s.On the other hand,EL techniques improved the accuracy in detecting fiberoptic faults.Thus,this research comprehensively assesses accuracy and delay metrics for various classifiers andproposes the most efficient attack detection system in fiber optics. 展开更多
关键词 Fiber optics fault detection multiclassification machine learning ensemble learning
下载PDF
Symmetry transformation of nonlinear optical current of tilted Weyl nodes and application to ferromagnetic MnBi_(2)Te_(4)
17
作者 卢倬成 冯济 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第4期160-171,共12页
A Weyl node is characterized by its chirality and tilt.We develop a theory of how nth-order nonlinear optical conductivity behaves under transformations of anisotropic tensor and tilt, which clarifies how chirality-de... A Weyl node is characterized by its chirality and tilt.We develop a theory of how nth-order nonlinear optical conductivity behaves under transformations of anisotropic tensor and tilt, which clarifies how chirality-dependent and-independent parts of optical conductivity transform under the reversal of tilt and chirality.Built on this theory, we propose ferromagnetic Mn Bi2Te4as a magnetoelectrically regulated, terahertz optical device, by magnetoelectrically switching the chiralitydependent and-independent DC photocurrents.These results are useful for creating nonlinear optical devices based on the topological Weyl semimetals. 展开更多
关键词 nonlinear optical response topological Weyl semimetals chiral anomaly
下载PDF
Controllable optical bistability in a Fabry-Pérot cavity with a nonlinear three-dimensional Dirac semimetal
18
作者 袁红霞 李佳雪 +5 位作者 马奇军 田海山 叶云洋 罗文昕 吴杏华 蒋乐勇 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第3期441-446,共6页
Optical bistability(OB)is capable of rapidly and reversibly transforming a parameter of an optical signal from one state to another,and homologous nonlinear optical bistable devices are core components of high-speed a... Optical bistability(OB)is capable of rapidly and reversibly transforming a parameter of an optical signal from one state to another,and homologous nonlinear optical bistable devices are core components of high-speed all-optical communication and all-optical networks.In this paper,we theoretically investigated the controllable OB from a Fabry-Pérot(FP)cavity with a nonlinear three-dimensional Dirac semimetal(3D DSM)in the terahertz band.The OB stems from the third-order nonlinear bulk conductivity of the 3D DSM and the resonance mode has a positive effect on the generation of OB.This FP cavity structure is able to tune the OB because the transmittance and the reflectance can be modulated by the Fermi energy of the 3D DSM.We believe that this FP cavity configuration could provide a reference concept for realizing tunable bistable devices. 展开更多
关键词 optical bistability Dirac semimetal Fabry-Pérot cavity
下载PDF
Coherent optical frequency transfer via 972-km fiber link
19
作者 邓雪 张翔 +8 位作者 臧琦 焦东东 王丹 刘杰 高静 许冠军 董瑞芳 刘涛 张首刚 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期277-282,共6页
We demonstrate coherent optical frequency dissemination over a distance of 972 km by cascading two spans where the phase noise is passively compensated for.Instead of employing a phase discriminator and a phase lockin... We demonstrate coherent optical frequency dissemination over a distance of 972 km by cascading two spans where the phase noise is passively compensated for.Instead of employing a phase discriminator and a phase locking loop in the conventional active phase control scheme,the passive phase noise cancellation is realized by feeding double-trip beat-note frequency to the driver of the acoustic optical modulator at the local site.This passive scheme exhibits fine robustness and reliability,making it suitable for long-distance and noisy fiber links.An optical regeneration station is used in the link for signal amplification and cascaded transmission.The phase noise cancellation and transfer instability of the 972-km link is investigated,and transfer instability of 1.1×10^(-19)at 10^(4)s is achieved.This work provides a promising method for realizing optical frequency distribution over thousands of kilometers by using fiber links. 展开更多
关键词 optical frequency transfer fiber link phase noise cancellation
下载PDF
Effect of a cervical collar on optic nerve sheath diameter in trauma patients
20
作者 Mümin Murat Yazici Ozcan Yavasi 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2024年第2期126-130,共5页
BACKGROUND:As advocated in advanced trauma life support and prehospital trauma life support protocols,cervical immobilization is applied until cervical spine injury is excluded.This study aimed to show the difference ... BACKGROUND:As advocated in advanced trauma life support and prehospital trauma life support protocols,cervical immobilization is applied until cervical spine injury is excluded.This study aimed to show the difference in optic nerve sheath diameter(ONSD)between patients with and without a cervical collar using computed tomography(CT).METHODS:This was a single-center,retrospective study examining trauma patients who presented to the emergency department between January 1,2021,and December 31,2021.The ONSD on brain CT of the trauma patients was measured and analyzed to determine whether there was a difference between the ONSD with and without the cervical collar.RESULTS:The study population consisted of 169 patients.On CT imaging of patients with(n=66)and without(n=103)cervical collars,the mean ONSD in the axial plane were 5.43±0.50 mm and 5.04±0.46 mm respectively for the right eye and 5.50±0.52 mm and 5.11±0.46 mm respectively for the left eye.The results revealed an association between the presence of a cervical collar and the mean ONSD,which was statistically significant(P<0.001)for both the right and left eyes.CONCLUSION:A cervical collar may be associated with increased ONSD.The effect of this increase in the ONSD on clinical outcomes needs to be investigated,and the actual need for cervical collar in the emergency department should be evaluated on a case-by-case basis. 展开更多
关键词 optic nerve sheath diameter Computed tomography TRAUMA Emergency medicine
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部