With the support by the National Natural Science Foundation of China,a collaborative study by the research group led by Prof.Zhang Zhidong(张志东)and Prof.Han Zheng(韩拯)from the Institute of Metal Research,Chinese Ac...With the support by the National Natural Science Foundation of China,a collaborative study by the research group led by Prof.Zhang Zhidong(张志东)and Prof.Han Zheng(韩拯)from the Institute of Metal Research,Chinese Academy of Sciences demonstrates that by intercalating a tunneling layer展开更多
AIM: To compare the anterior segment measurements obtained by rotating Scheimpflug camera(Pentacam) and Scanning-slit topography(Orbscan IIz) in keratoconic eyes.METHODS: A total of 121 patients, 71 males(58.7%)and 50...AIM: To compare the anterior segment measurements obtained by rotating Scheimpflug camera(Pentacam) and Scanning-slit topography(Orbscan IIz) in keratoconic eyes.METHODS: A total of 121 patients, 71 males(58.7%)and 50 females(41.3%)(214 eyes) with the diagnosis of keratoconus(KC) were enrolled in this study. Following diagnosis of KC by slit-lamp biomicroscopic examination, central corneal thickness(CCT), thinnest corneal thickness(TCT), anterior chamber depth(ACD),and pupil diameter(PD) were measured by a single examiner using successive instrumentation by Pentacam and Orbscan.RESULTS: There was no significant difference between the two instruments for the measurement of CCT and TCT. In contrast, scanning-slit topography measured ACD(3.46±0.40 mm vs 3.38±0.33 mm, P =0.019) and PD(4.97 ±1.26 mm vs 4.08 ±1.19 mm, P 【0.001) significantly larger than rotating Scheimpflug camera.The two devices made similar measurements for CCT(95% CI:-2.94 to5.06, P =0.602). However, the mean difference for TCT was-6.28(95% CI:-10.51 to-2.06, P =0.004) showing a thinner measurement by Orbscan than by Pentacam. In terms of the ACD, the mean difference was 0.08 mm(95%CI: 0.04 to 0.12, P 【0.001) with Orbscan giving a slightly larger value than Pentacam. Similarly, Orbscan measurement for PD was longer than Pentacam(95% CI:0.68 to 1.08, P 【0.001).CONCLUSION: A good agreement was found between Pentacam and Orbscan concerning CCT measurement while comparing scanning-slit topography and rotatingScheimpflug camera there was an underestimation for TCT and overestimation for ACD and PD.展开更多
文摘With the support by the National Natural Science Foundation of China,a collaborative study by the research group led by Prof.Zhang Zhidong(张志东)and Prof.Han Zheng(韩拯)from the Institute of Metal Research,Chinese Academy of Sciences demonstrates that by intercalating a tunneling layer
文摘AIM: To compare the anterior segment measurements obtained by rotating Scheimpflug camera(Pentacam) and Scanning-slit topography(Orbscan IIz) in keratoconic eyes.METHODS: A total of 121 patients, 71 males(58.7%)and 50 females(41.3%)(214 eyes) with the diagnosis of keratoconus(KC) were enrolled in this study. Following diagnosis of KC by slit-lamp biomicroscopic examination, central corneal thickness(CCT), thinnest corneal thickness(TCT), anterior chamber depth(ACD),and pupil diameter(PD) were measured by a single examiner using successive instrumentation by Pentacam and Orbscan.RESULTS: There was no significant difference between the two instruments for the measurement of CCT and TCT. In contrast, scanning-slit topography measured ACD(3.46±0.40 mm vs 3.38±0.33 mm, P =0.019) and PD(4.97 ±1.26 mm vs 4.08 ±1.19 mm, P 【0.001) significantly larger than rotating Scheimpflug camera.The two devices made similar measurements for CCT(95% CI:-2.94 to5.06, P =0.602). However, the mean difference for TCT was-6.28(95% CI:-10.51 to-2.06, P =0.004) showing a thinner measurement by Orbscan than by Pentacam. In terms of the ACD, the mean difference was 0.08 mm(95%CI: 0.04 to 0.12, P 【0.001) with Orbscan giving a slightly larger value than Pentacam. Similarly, Orbscan measurement for PD was longer than Pentacam(95% CI:0.68 to 1.08, P 【0.001).CONCLUSION: A good agreement was found between Pentacam and Orbscan concerning CCT measurement while comparing scanning-slit topography and rotatingScheimpflug camera there was an underestimation for TCT and overestimation for ACD and PD.