Three-dimensional speckle tracking echocardiography was employed to evaluate the changes of left ventricular systolic strain in 23 heart transplant recipients at 1 st, 3rd, 6th and 12th month after heart transplantati...Three-dimensional speckle tracking echocardiography was employed to evaluate the changes of left ventricular systolic strain in 23 heart transplant recipients at 1 st, 3rd, 6th and 12th month after heart transplantation, and 23 healthy subjects served as controls. The three-dimensional full-volume echocardiographic images of left ventricle were recorded and then were analyzed using EchoPAC software. The strain curves and peak systolic strain values for each segment and overall left ventricular wall were obtained. Left ventricular global peak longitudinal strain (GPSL), global peak radial strain (GPSR), global peak circumferential strain (GPSC) and global peak area strain (GPSA) were measured and then statistically analyzed. There were no significant differences in left ventricular ejection fraction (LVEF) and cardiac output (CO) between heart transplant recipients and controls. The GPSL in heart transplant recipients at 1st month after surgery was significantly lower than that in controls, but close to the normal value at 3rd month after surgery and later. The GPSC, GPSA and GPSR were significantly lower in heart transplant recipients at 1 st, 3rd, 6th and 12th month after surgery than those in controls. It is suggested that three-dimensional speckle tracking echocardiography can be used for monitoring changes of left ventricular systolic strains and evaluating left ventricular systolic function in cardiac allograft.展开更多
Background Two-dimensional speckle tracking imaging (2D-STI) and real-time three-dimensional echocardiography (RT-3DE) have more advantages in evaluating left ventricular (LV) systolic dyssynchrony than traditio...Background Two-dimensional speckle tracking imaging (2D-STI) and real-time three-dimensional echocardiography (RT-3DE) have more advantages in evaluating left ventricular (LV) systolic dyssynchrony than traditional echocardiographic techniques. The study aimed to evaluate LV dyssynchrony parameters by both 2D-STI and RT-3DE, and the correlation between these two techniques. Methods A total of 43 chronic heart failure (CHF) patients and 27 healthy volunteers were enrolled. There were 23 dyssynchrony parameters selected to evaluate left ventricular systolic synchronization, involving 15 from 2D-STI and 8 from RT-3DE. Results Few of the dyssynchrony parametersshowednegative correlations with LV ejection fraction (LVEF) in the CHF group. The difference between time to peak-systolic radial strain of the anteroseptal and posterior segments at the level of papillary muscles [AS-P(RS)] from 2D-STI showed positive correlations with parts of the parameters from RT-3DE (P 〈 0.05). Conclusions LV systolic dysfunction does not correlate with dyssynchrony. Moreover, there is a weak association between 2D-STI and RT-3DE in assessment of left ventricular dyssynchrony.展开更多
基金supported by Innovation Research Fund of Huazhong University of Science and Technology,China(No.2012QN183)
文摘Three-dimensional speckle tracking echocardiography was employed to evaluate the changes of left ventricular systolic strain in 23 heart transplant recipients at 1 st, 3rd, 6th and 12th month after heart transplantation, and 23 healthy subjects served as controls. The three-dimensional full-volume echocardiographic images of left ventricle were recorded and then were analyzed using EchoPAC software. The strain curves and peak systolic strain values for each segment and overall left ventricular wall were obtained. Left ventricular global peak longitudinal strain (GPSL), global peak radial strain (GPSR), global peak circumferential strain (GPSC) and global peak area strain (GPSA) were measured and then statistically analyzed. There were no significant differences in left ventricular ejection fraction (LVEF) and cardiac output (CO) between heart transplant recipients and controls. The GPSL in heart transplant recipients at 1st month after surgery was significantly lower than that in controls, but close to the normal value at 3rd month after surgery and later. The GPSC, GPSA and GPSR were significantly lower in heart transplant recipients at 1 st, 3rd, 6th and 12th month after surgery than those in controls. It is suggested that three-dimensional speckle tracking echocardiography can be used for monitoring changes of left ventricular systolic strains and evaluating left ventricular systolic function in cardiac allograft.
文摘Background Two-dimensional speckle tracking imaging (2D-STI) and real-time three-dimensional echocardiography (RT-3DE) have more advantages in evaluating left ventricular (LV) systolic dyssynchrony than traditional echocardiographic techniques. The study aimed to evaluate LV dyssynchrony parameters by both 2D-STI and RT-3DE, and the correlation between these two techniques. Methods A total of 43 chronic heart failure (CHF) patients and 27 healthy volunteers were enrolled. There were 23 dyssynchrony parameters selected to evaluate left ventricular systolic synchronization, involving 15 from 2D-STI and 8 from RT-3DE. Results Few of the dyssynchrony parametersshowednegative correlations with LV ejection fraction (LVEF) in the CHF group. The difference between time to peak-systolic radial strain of the anteroseptal and posterior segments at the level of papillary muscles [AS-P(RS)] from 2D-STI showed positive correlations with parts of the parameters from RT-3DE (P 〈 0.05). Conclusions LV systolic dysfunction does not correlate with dyssynchrony. Moreover, there is a weak association between 2D-STI and RT-3DE in assessment of left ventricular dyssynchrony.