Objective: The aim of the study was to compare the difference of dose distribution in clinical target volume and organ at risk (OAR) between five-field intensity-modulated radiotherapy (IMRT) and conventional thr...Objective: The aim of the study was to compare the difference of dose distribution in clinical target volume and organ at risk (OAR) between five-field intensity-modulated radiotherapy (IMRT) and conventional three-dimensional conformal radiotherapy (3DCRT) in the radiotherapy of rectal cancer. Methods: Fifteen patients with rectal cancer treated with radio- therapy (RT) were retrospectively analyzed. Among the patients, seven received RT preoperatively and 8 postoperatively. The target volume and the OARs such as the small bowel, bladder and femoral heads were contoured for each patient. 3DCRT-plan and IMRT-plan were performed for each patient respectively, with the prescribed dose covering at least 95% of the planning target volume (PTV). The conformity index (CI) and homogeneity index (HI) were used for evaluation of the dose distribution in the target volume, and the Dx% (the lowest dose to the x% volume of the OARs that received the highest dose of irradiation) and the mean dose were used for evaluation of the dose to OARs. Paired-T test was used for companson of the difference between the two plans. Results: In the IMRT-plan and 3DCRT-plan, the CI were 0.94 and 0.87 (P = 0.000) and the HI were 1.13 and 1.17, respectively (P = 0.001). For small bowel, the D30%, D50% and the mean dose were 19.67 Gy, 15.13 Gy and 18.81 Gy in the IMRT-plan and 25.20 Gy, 22.20 Gy and 22.89 Gy in the 3DCRT-plan, respectively (P 〈 0.001 for all pairs of parameters). For bladder, the D30%, D50%, and the mean dose were 24.80 Gy, 34.20 Gy and 28.70 Gy in the IMRT- plan, and 35.07 Gy, 44.67 Gy and 35.68 Gy in the 3DCRT-plan, respectively (P 〈 0.001 for all pairs of parameters). For femoral heads, the D5% in the IMRT-plan and 3DCRT-plan were 40.6 Gy and 40.47 Gy, respectively (P = 0.936), and the mean dose were 30.14 Gy and 25.57 Gy, respectively (P = 0.001). Conclusion: Five-field IMRT-plan is better than 3DCRT-plan in the conformity and the dose homogeneity within target volume and also better in sparing the small bowel and bladder.展开更多
Objective: The aim of the study was to evaluate the therapeutic effect and safety of whole-course three-dimensional conformal radiotherapy (3DCRT) combined with late-course accelerated hyperfractionated radiothera...Objective: The aim of the study was to evaluate the therapeutic effect and safety of whole-course three-dimensional conformal radiotherapy (3DCRT) combined with late-course accelerated hyperfractionated radiotherapy (LCAFR) on patients with esophageal carcinoma. Methods: one hundred and one patients with esophageal carcinoma were divided into two groups. Observing group (49 cases) were treated by whole-course 3DCRT. Patients in control group (52 cases) were treated by conventional radiotherapy. Clinical efficiencies and radiation toxicities were compared between two groups. Results: The side effects including radiation esophagitis (63.2%) and tracheitis (49.0%) decreased in observing group, but there was no significant difference between two groups (69.2% and 55.7% in controls). The 1-, 2-and 3-year tumor local control rates and overall survival rates in the observing group were significantly improved compared with the control group, being respectively 87.8%, 75.5%, 63.3% vs 71.2%, 55.8%, 42.3% and 85.7%, 71.4%, 46.7% vs 69.2%, 51.9%, 26.9% (all P 0.05). Conclusion: The therapeutic effect of whole-course 3DCRT combined with LCAFR for esophageal carcinomas is superior to conventional radiotherapy.展开更多
Objective:Prostate cancer is a form of cancer that develops in the prostate,a gland in the male reproductive system.Prostate cancer tends to develop in men over the age of fifty;it is one of the most prevalent types o...Objective:Prostate cancer is a form of cancer that develops in the prostate,a gland in the male reproductive system.Prostate cancer tends to develop in men over the age of fifty;it is one of the most prevalent types of cancer in men.This article introduced a new method of prostate cancer treatment with the combination of three dimensional conformal radiation therapy (3D-CRT) and high-intensity focused ultrasound (HIFU),its efficacy was evaluated.Methods:From January 2004 to December 2009,95 patients were diagnosed with prostate cancer,among them,48 patients were received combined therapy with total irradiation of TD 60 Gy/30 Fx and 5 fractions of HIFU treatment,while 47 patients were received with pure 3D-CRT with total irradiation of TD (66-72) Gy/(33-36) Fx.Various indicators were evaluated,such as the local control rate and distant metastasis rate,the changes in blood PSA and fPSA,changes in T-lymphocyte subsets and NK cells,as well as acute adverse reaction of normal tissue.Results:The local response rate difference between the two groups had statistical significance (P < 0.05);the changes in blood PSA and fPSA were significant (P < 0.05);CD3+,CD4+,CD8+,CD4+/CD8+ and NK cells of the combined group increased obviously (P < 0.01),while the latter group had no increase (P > 0.05);the combined group had lower blood cells reduction and II-level acute adverse reaction of rectum,bladder and caput humeri than the pure group,but the II-level acute adverse reaction of urogenital canal in the combined group was higher (P < 0.05).Conclusion:The combined therapy with 3D-CRT and HIFU is a good way for the treatment of aged-related prostate cancer.It can ease the symptoms,control the disease and lengthen the survival time.展开更多
Objective: To study the toxicities and efficacy of concurrent gemcitabine plus cisplatin combined with three-dimensional conformal radiotherapy for stage Ⅲ non-small cell lung cancer (NSCLC). Methods: Thirty-six ...Objective: To study the toxicities and efficacy of concurrent gemcitabine plus cisplatin combined with three-dimensional conformal radiotherapy for stage Ⅲ non-small cell lung cancer (NSCLC). Methods: Thirty-six patients with pathologically diagnosed NSCLC received radiotherapy and concurrent chemotherapy. There were 22 patients with stage Ilia and 14 patients with IIIb. Radiotherapy was given a total of 60-70 Gy in conventional fractionation. Chemotherapy included gemcitabine (600 mg/m^2) and cisplatin (20 mg/m^2), once per week. Results: Thirty-two patients received a total dose of 60-72 Gy. Two patients received 56 Gy and another two patients received 58 Gy. Thirty-four patients received 4-6 weeks of chemotherapy, while two patients received only 2 weeks of chemotherapy. The overall response rate (CR + PR), complete response rate (CR), partially response rate (PR) were 83.3% (30/36), 11.1% (4/36) and 72.2% (26/36) respectively. The median follow-up duration was 18.4 months. The 1- and 2-year overall survival rates were 77.8% (28/36) and 55.6% (20/36), respectively. Conclusion: Concurrent gemcitabine and cisplatin combined with three-dimensional conformal radiotherapy for stage III non-small cell lung cancer is effective and well tolerated. Lone-term results need further study.展开更多
Objective: The purpose of this study was to investigate the impact of intensity modulated radiotherapy (IMRT) on surface doses for brain, abdomen and pelvis deep located tumors treated with 6 MV photon and to evaluate...Objective: The purpose of this study was to investigate the impact of intensity modulated radiotherapy (IMRT) on surface doses for brain, abdomen and pelvis deep located tumors treated with 6 MV photon and to evaluate the skin dose calculation accuracy of the XIO 4.04 treatment planning system. Methods: More investigations for the influences of IMRT on skin doses would increase its applications for many treatment sites. Measuring skin doses in real treatment situations would reduce the uncertainty of skin dose prediction. In this work a pediatric human phantom was covered by a layer of 1 mm bolus at three treatment sites and thermoluminescent dosimeter (TLD) chips were inserted into the bolus at each treatment site before CT scan. Two different treatment plans [three-dimensional conformal radiation therapy (3DCRT) and IMRT] for each treatment sites were performed on XIO 4.04 treatment planning system using superposition algorism. Results: The results showed that the surface doses for 3DCRT were higher than the surface doses in IMRT by 1.6%, 2.5% and 3.2% for brain, abdomen and pelvis sites respectively. There was good agreement between measured and calculated surface doses, where the calculated surface dose was 15.5% for brain tumor calculated with 3DCRT whereas the measured surface dose was 12.1%. For abdomen site the calculated surface dose for IMRT treatment plan was 16.5% whereas the measured surface dose was 12.6%. Conclusion: The skin dose in IMRT for deep seated tumors is lower than that in 3DCRT which is another advantage for the IMRT. The TLD readings showed that the difference between the calculated and measured point dose is negligible. The superposition calculation algorism of the XIO 4.04 treatment planning system modeled the superficial dose well.展开更多
文摘Objective: The aim of the study was to compare the difference of dose distribution in clinical target volume and organ at risk (OAR) between five-field intensity-modulated radiotherapy (IMRT) and conventional three-dimensional conformal radiotherapy (3DCRT) in the radiotherapy of rectal cancer. Methods: Fifteen patients with rectal cancer treated with radio- therapy (RT) were retrospectively analyzed. Among the patients, seven received RT preoperatively and 8 postoperatively. The target volume and the OARs such as the small bowel, bladder and femoral heads were contoured for each patient. 3DCRT-plan and IMRT-plan were performed for each patient respectively, with the prescribed dose covering at least 95% of the planning target volume (PTV). The conformity index (CI) and homogeneity index (HI) were used for evaluation of the dose distribution in the target volume, and the Dx% (the lowest dose to the x% volume of the OARs that received the highest dose of irradiation) and the mean dose were used for evaluation of the dose to OARs. Paired-T test was used for companson of the difference between the two plans. Results: In the IMRT-plan and 3DCRT-plan, the CI were 0.94 and 0.87 (P = 0.000) and the HI were 1.13 and 1.17, respectively (P = 0.001). For small bowel, the D30%, D50% and the mean dose were 19.67 Gy, 15.13 Gy and 18.81 Gy in the IMRT-plan and 25.20 Gy, 22.20 Gy and 22.89 Gy in the 3DCRT-plan, respectively (P 〈 0.001 for all pairs of parameters). For bladder, the D30%, D50%, and the mean dose were 24.80 Gy, 34.20 Gy and 28.70 Gy in the IMRT- plan, and 35.07 Gy, 44.67 Gy and 35.68 Gy in the 3DCRT-plan, respectively (P 〈 0.001 for all pairs of parameters). For femoral heads, the D5% in the IMRT-plan and 3DCRT-plan were 40.6 Gy and 40.47 Gy, respectively (P = 0.936), and the mean dose were 30.14 Gy and 25.57 Gy, respectively (P = 0.001). Conclusion: Five-field IMRT-plan is better than 3DCRT-plan in the conformity and the dose homogeneity within target volume and also better in sparing the small bowel and bladder.
文摘Objective: The aim of the study was to evaluate the therapeutic effect and safety of whole-course three-dimensional conformal radiotherapy (3DCRT) combined with late-course accelerated hyperfractionated radiotherapy (LCAFR) on patients with esophageal carcinoma. Methods: one hundred and one patients with esophageal carcinoma were divided into two groups. Observing group (49 cases) were treated by whole-course 3DCRT. Patients in control group (52 cases) were treated by conventional radiotherapy. Clinical efficiencies and radiation toxicities were compared between two groups. Results: The side effects including radiation esophagitis (63.2%) and tracheitis (49.0%) decreased in observing group, but there was no significant difference between two groups (69.2% and 55.7% in controls). The 1-, 2-and 3-year tumor local control rates and overall survival rates in the observing group were significantly improved compared with the control group, being respectively 87.8%, 75.5%, 63.3% vs 71.2%, 55.8%, 42.3% and 85.7%, 71.4%, 46.7% vs 69.2%, 51.9%, 26.9% (all P 0.05). Conclusion: The therapeutic effect of whole-course 3DCRT combined with LCAFR for esophageal carcinomas is superior to conventional radiotherapy.
基金Supported by agrant from the Network Researches of Tumor Precise Radiation Therapy of Ministry of Health of China(No.WKJ2005-3-006)
文摘Objective:Prostate cancer is a form of cancer that develops in the prostate,a gland in the male reproductive system.Prostate cancer tends to develop in men over the age of fifty;it is one of the most prevalent types of cancer in men.This article introduced a new method of prostate cancer treatment with the combination of three dimensional conformal radiation therapy (3D-CRT) and high-intensity focused ultrasound (HIFU),its efficacy was evaluated.Methods:From January 2004 to December 2009,95 patients were diagnosed with prostate cancer,among them,48 patients were received combined therapy with total irradiation of TD 60 Gy/30 Fx and 5 fractions of HIFU treatment,while 47 patients were received with pure 3D-CRT with total irradiation of TD (66-72) Gy/(33-36) Fx.Various indicators were evaluated,such as the local control rate and distant metastasis rate,the changes in blood PSA and fPSA,changes in T-lymphocyte subsets and NK cells,as well as acute adverse reaction of normal tissue.Results:The local response rate difference between the two groups had statistical significance (P < 0.05);the changes in blood PSA and fPSA were significant (P < 0.05);CD3+,CD4+,CD8+,CD4+/CD8+ and NK cells of the combined group increased obviously (P < 0.01),while the latter group had no increase (P > 0.05);the combined group had lower blood cells reduction and II-level acute adverse reaction of rectum,bladder and caput humeri than the pure group,but the II-level acute adverse reaction of urogenital canal in the combined group was higher (P < 0.05).Conclusion:The combined therapy with 3D-CRT and HIFU is a good way for the treatment of aged-related prostate cancer.It can ease the symptoms,control the disease and lengthen the survival time.
文摘Objective: To study the toxicities and efficacy of concurrent gemcitabine plus cisplatin combined with three-dimensional conformal radiotherapy for stage Ⅲ non-small cell lung cancer (NSCLC). Methods: Thirty-six patients with pathologically diagnosed NSCLC received radiotherapy and concurrent chemotherapy. There were 22 patients with stage Ilia and 14 patients with IIIb. Radiotherapy was given a total of 60-70 Gy in conventional fractionation. Chemotherapy included gemcitabine (600 mg/m^2) and cisplatin (20 mg/m^2), once per week. Results: Thirty-two patients received a total dose of 60-72 Gy. Two patients received 56 Gy and another two patients received 58 Gy. Thirty-four patients received 4-6 weeks of chemotherapy, while two patients received only 2 weeks of chemotherapy. The overall response rate (CR + PR), complete response rate (CR), partially response rate (PR) were 83.3% (30/36), 11.1% (4/36) and 72.2% (26/36) respectively. The median follow-up duration was 18.4 months. The 1- and 2-year overall survival rates were 77.8% (28/36) and 55.6% (20/36), respectively. Conclusion: Concurrent gemcitabine and cisplatin combined with three-dimensional conformal radiotherapy for stage III non-small cell lung cancer is effective and well tolerated. Lone-term results need further study.
文摘Objective: The purpose of this study was to investigate the impact of intensity modulated radiotherapy (IMRT) on surface doses for brain, abdomen and pelvis deep located tumors treated with 6 MV photon and to evaluate the skin dose calculation accuracy of the XIO 4.04 treatment planning system. Methods: More investigations for the influences of IMRT on skin doses would increase its applications for many treatment sites. Measuring skin doses in real treatment situations would reduce the uncertainty of skin dose prediction. In this work a pediatric human phantom was covered by a layer of 1 mm bolus at three treatment sites and thermoluminescent dosimeter (TLD) chips were inserted into the bolus at each treatment site before CT scan. Two different treatment plans [three-dimensional conformal radiation therapy (3DCRT) and IMRT] for each treatment sites were performed on XIO 4.04 treatment planning system using superposition algorism. Results: The results showed that the surface doses for 3DCRT were higher than the surface doses in IMRT by 1.6%, 2.5% and 3.2% for brain, abdomen and pelvis sites respectively. There was good agreement between measured and calculated surface doses, where the calculated surface dose was 15.5% for brain tumor calculated with 3DCRT whereas the measured surface dose was 12.1%. For abdomen site the calculated surface dose for IMRT treatment plan was 16.5% whereas the measured surface dose was 12.6%. Conclusion: The skin dose in IMRT for deep seated tumors is lower than that in 3DCRT which is another advantage for the IMRT. The TLD readings showed that the difference between the calculated and measured point dose is negligible. The superposition calculation algorism of the XIO 4.04 treatment planning system modeled the superficial dose well.