期刊文献+
共找到151篇文章
< 1 2 8 >
每页显示 20 50 100
Performance optimization of a SERF atomic magnetometer based on flat-top light beam
1
作者 袁子琪 唐钧剑 +1 位作者 林树东 翟跃阳 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第6期330-336,共7页
We explore the impact of pumping beams with different transverse intensity profiles on the performance of the spinexchange relaxation-free(SERF) atomic magnetometers(AMs). We conduct experiments comparing the traditio... We explore the impact of pumping beams with different transverse intensity profiles on the performance of the spinexchange relaxation-free(SERF) atomic magnetometers(AMs). We conduct experiments comparing the traditional Gaussian optically-pumped AM with that utilizing the flat-top optically-pumped(FTOP) method. Our findings reveal that the FTOP-based approach outperforms the conventional method, exhibiting a larger response, a narrower magnetic resonance linewidth, and a superior low-frequency noise performance. Specifically, the use of FTOP method leads to a 16% enhancement in average sensitivity within 1 Hz–30 Hz frequency range. Our research emphasizes the significance of achieving transverse polarization uniformity in AMs, providing insights for future optimization efforts and sensitivity improvements in miniaturized magnetometers. 展开更多
关键词 atomic magnetometer(AM) spin-exchange relaxation-free(SERF) flat-top light beam performance optimization
下载PDF
Response optimization of a three-axis sensitive SERF magnetometer for closed-loop operation
2
作者 周原锐 孙永泽 +3 位作者 汪茜茜 秦佳男 张雪 王言章 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第2期291-297,共7页
Most triaxial-vectorial magnetic field measurements with spin-exchange relaxation free(SERF)atomic magnetometer(AM)are based on the quasi-steady-state solution of the Bloch equation.However,the responding speed of the... Most triaxial-vectorial magnetic field measurements with spin-exchange relaxation free(SERF)atomic magnetometer(AM)are based on the quasi-steady-state solution of the Bloch equation.However,the responding speed of these methods is greatly limited because the frequency of the modulation signal should be slow enough to ensure the validity of the quasi-steady-state solution.In this work,a new model to describe the response of the three-axis sensitive SERF AM with high modulation frequency is presented and verified.The response of alkali-atomic spin to high-frequency modulation field is further investigated by solving the Bloch equation in a modulation-frequency-dependence manner.This solution is well verified by our experiments and can offer a reference for selection of modulation frequencies.The result shows a potential to achieve a SERF AM operating in a geomagnetic field without heavy aluminum shielding when the modulation frequencies are selected properly. 展开更多
关键词 triaxial-vectorial magnetic field measurement spin-exchange relaxation free atomic magnetometer
下载PDF
A compact and closed-loop spin-exchange relaxation-free atomic magnetometer for wearable magnetoencephalography
3
作者 郭清乾 胡涛 +10 位作者 冯晓宇 张明康 陈春巧 张欣 姚泽坤 徐佳玉 王青 付方跃 张寅 常严 杨晓冬 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第4期277-282,共6页
Atomic magnetometers operated in the spin-exchange relaxation-free(SERF)regime are the promising sensor to replace superconducting quantum interference devices(SQUIDs)in the biomagnetism field.The SERF magnetometer wi... Atomic magnetometers operated in the spin-exchange relaxation-free(SERF)regime are the promising sensor to replace superconducting quantum interference devices(SQUIDs)in the biomagnetism field.The SERF magnetometer with compact size and good performance is crucial to the new generation of wearable magnetoencephalography(MEG)system.In this paper,we developed a compact and closed-loop SERF magnetometer with the dimensions of 15.0×22.0×30.0 mm^(3)based on a single-beam configuration.The bandwidth of the magnetometer was extended to 675 Hz while the sensitivity was maintained at 22 f T/Hz^(1/2).A nearly 3-fold enhancement of the bandwidth was obtained in comparison with the open-loop control.The implementation of the closed-loop control also greatly improved the dynamic range,enabling the magnetometer to be robust against the disturbance of the ambient field.Moreover,the magnetometer was successfully applied for the detection of humanα-rhythm and auditory evoked fields(AEFs),which demonstrated the potential to be extended to multi-channel MEG measurements for future neuroscience studies. 展开更多
关键词 atomic magnetometer MINIATURIZATION CLOSED-LOOP magnetoencephalography(MEG)
下载PDF
A miniaturized spin-exchange relaxation-free atomic magnetometer based on uniform light field
4
作者 李佳洁 房秀杰 +3 位作者 李任杰 陈宝栋 翟跃阳 刘颖 《Chinese Physics B》 SCIE EI CAS CSCD 2023年第5期378-383,共6页
We experimentally study the dynamic characteristics of a miniaturized spin-exchange relaxation-free(SERF) magnetometer based on uniform light field. The ceramic ferrule is used to expand the Gaussian beam to improve l... We experimentally study the dynamic characteristics of a miniaturized spin-exchange relaxation-free(SERF) magnetometer based on uniform light field. The ceramic ferrule is used to expand the Gaussian beam to improve light intensity uniformity, while the volume of the sensor is also reduced. This scheme makes the magnetometer have better sensitivity when the detected light intensity is less than 3.16 m W/cm^(2) at 120℃. When the temperature rises to 150℃ the sensitivity under the action of uniform light field is 18.5 f T/Hz^(1/2). The bandwidth of the sensor remains at the original level and meets application needs. The proposed structure improves transverse polarization uniformity within the miniaturized sensor, which is ideal for the magnetoencephalography and magnetocardiography imaging systems. 展开更多
关键词 atomic magnetometer uniform light field POLARIZATION sensitivity
下载PDF
High contrast atomic magnetometer based on coherent population trapping 被引量:2
5
作者 杨爱林 杨国卿 +1 位作者 徐云飞 林强 《Chinese Physics B》 SCIE EI CAS CSCD 2014年第2期477-480,共4页
We present an experimental and theoretical investigation of the coherent population trapping (CPT) resonance excited on the D1 line of 87Rb atoms by bichromatic linearly polarized laser light. The experimental resul... We present an experimental and theoretical investigation of the coherent population trapping (CPT) resonance excited on the D1 line of 87Rb atoms by bichromatic linearly polarized laser light. The experimental results show that a lin||lin tran- sition scheme is a promising alternative to the conventional circular-circular transition scheme for an atomic magnetometer. Compared with the circular light transition scheme, linear light accounts for high-contrast transmission resonances, which makes this excitation scheme promising for high-sensitivity magnetometers. We also use linear light and circular light to detect changes of a standard magnetic field, separately. 展开更多
关键词 high contrast atomic magnetometer coherent population trapping
下载PDF
A dual-axis, high-sensitivity atomic magnetometer 被引量:1
6
作者 李茹杰 全伟 +4 位作者 范文峰 邢力 王卓 翟跃阳 房建成 《Chinese Physics B》 SCIE EI CAS CSCD 2017年第12期196-200,共5页
Atomic magnetometer (AM) operated in a spin-exchange relaxation-free (SERF) regime features superior sensitivity and non-cryogenic operation, and thus is competitive with the best superconducting quantum interfere... Atomic magnetometer (AM) operated in a spin-exchange relaxation-free (SERF) regime features superior sensitivity and non-cryogenic operation, and thus is competitive with the best superconducting quantum interference devices. Previously, SERF AM with fT/Hz1/2 level sensitivity commonly acted as a single-axis sensor. Here we demonstrate a dual-axis SERF AM capable of simultaneously and independently detecting x-and y-field components with a sensitivity of 20 fT/Hz1/2. As there is no necessity to worry about the cross-talk effects arising from field modulations, the dual-axis scheme proposed here is of particular interest to AM array and hence the biomagnetic applications. 展开更多
关键词 optically pumped magnetometers multi-axis field measurements high-sensitivity field measurements polarized atoms
下载PDF
A modified analytical model of the alkali-metal atomic magnetometer employing longitudinal carrier field 被引量:2
7
作者 Chang Chen Yi Zhang +4 位作者 Zhi-Guo Wang Qi-Yuan Jiang Hui Luo Kai-Yong Yang 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第5期302-311,共10页
Alkali-metal atomic magnetometers employing longitudinal carrier magnetic field have ultrahigh sensitivity to measure transverse magnetic fields and have been applied in a variety of precise-measurement science and te... Alkali-metal atomic magnetometers employing longitudinal carrier magnetic field have ultrahigh sensitivity to measure transverse magnetic fields and have been applied in a variety of precise-measurement science and technologies.In practice,the magnetometer response is not rigorously proportional to the measured transverse magnetic fields and the existing fundamental analytical model of this magnetometer is effective only when the amplitudes of the measured fields are very small.In this paper,we present a modified analytical model to characterize the practical performance of the magnetometer more definitely.We find out how the longitudinal magnetization of the alkali metal atoms vary with larger transverse fields.The linear-response capacity of the magnetometer is determined by these factors:the amplitude and frequency of the longitudinal carrier field,longitudinal and transverse spin relaxation time of the alkali spins and rotation frequency of the transverse fields.We give a detailed and rigorous theoretical derivation by using the perturbation-iteration method and simulation experiments are conducted to verify the validity and correctness of the proposed modified model.This model can be helpful for measuring larger fields more accurately and configuring a desirable magnetometer with proper linear range. 展开更多
关键词 alkali-metal atomic magnetometer longitudinal carrier magnetic field linear-response capacity
下载PDF
A laser pump-re-pump atomic magnetometer 被引量:2
8
作者 杨爱林 杨国卿 +2 位作者 蔡勋明 徐云飞 林强 《Chinese Physics B》 SCIE EI CAS CSCD 2013年第12期177-181,共5页
We demonstrate experimentally an atomic magnetometer based on optical pumping theory, a magnetic resonance that is induced by a radio frequency field and dependent on the magnetic field strength. Compared with the con... We demonstrate experimentally an atomic magnetometer based on optical pumping theory, a magnetic resonance that is induced by a radio frequency field and dependent on the magnetic field strength. Compared with the conventional method using one radiation field, which is used not only as the probe beam but also as a pump beam, the additional re-pump beam can increase remarkably the amplitude of the signal. It is shown that the amplitude of the magnetic field resonance signal can increase more than 55% by using an additional re-pump beam, which makes the sensitivity of the magnetometer higher. Finally, we investigate the relation between amplitude of the signal and re-pump laser power, and calculate the atomic population in the trapping states with rate equations. 展开更多
关键词 atomic magnetometer optical pumping sensitivity
下载PDF
Search for topological defect of axionlike model with cesium atomic comagnetometer 被引量:1
9
作者 Yucheng Yang Teng Wu +1 位作者 Jianwei Zhang Hong Guo 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第5期157-164,共8页
Many terrestrial experiments have been designed to detect domain walls composed of axions or axionlike particles(ALPs), which are promising candidates of dark matter. When the domain wall crosses over the Earth, the p... Many terrestrial experiments have been designed to detect domain walls composed of axions or axionlike particles(ALPs), which are promising candidates of dark matter. When the domain wall crosses over the Earth, the pseudoscalar field of ALPs could couple to the atomic spins. Such exotic spin-dependent couplings can be searched for by monitoring the transient-in-time change of the atomic spin precession frequency in the presence of a magnetic field. We propose here a single-species cesium atomic comagnetometer, which measures the spin precession frequencies of atoms in different ground-state hyperfine levels, to eliminate the common-mode magnetic-field variations and search for the exotic nonmagnetic couplings solely between protons and ALPs. With the single-species atomic comagnetometer, we experimentally rule out the possibility that the decay constant of the linear pseudoscalar couplings of ALPs to protons is fp■ 3.71 ×107 Ge V. The advanced system has the potential to constrain the constant to be fp■ 10.7 × 109 Ge V, promising to improve astrophysical constraint level by at least one order of magnitude. Our system could provide a sensitive detection method for the global network of optical magnetometers to search for exotic physics. 展开更多
关键词 atomic comagnetometer atomic magnetometer domain wall axions and axionlike particles
下载PDF
Dynamic range and linearity improvement for zero-field single-beam atomic magnetometer 被引量:1
10
作者 Kai-Feng Yin Ji-Xi Lu +3 位作者 Fei Lu Bo Li Bin-Quan Zhou Mao Ye 《Chinese Physics B》 SCIE EI CAS CSCD 2022年第11期284-290,共7页
Zero-field single-beam atomic magnetometers with transverse parametric modulation for ultra-weak magnetic field detection have attracted widespread attention recently.In this study,we present a comprehensive response ... Zero-field single-beam atomic magnetometers with transverse parametric modulation for ultra-weak magnetic field detection have attracted widespread attention recently.In this study,we present a comprehensive response model and propose a modification method of conventional first harmonic response by introducing the second harmonic correction.The proposed modification method gives improvement in dynamic range and reduction of linearity error.Additionally,our modification method shows suppression of response instability caused by optical intensity and frequency fluctuations.An atomic magnetometer with single-beam configuration is built to compare the performance between our proposed method and the conventional method.The results indicate that our method’s magnetic field response signal achieves a 5-fold expansion of dynamic range from 2 nT to 10 nT,with the linearity error decreased from 5%to 1%.Under the fluctuations of 5%for optical intensity and±15 GHz detuning of frequency,the proposed modification method maintains intensityrelated instability less than 1%and frequency-related instability less than 8%while the conventional method suffers 15%and 38%,respectively.Our method is promising for future high-sensitive and long-term stable optically pumped atomic sensors. 展开更多
关键词 atomic magnetometer dynamic range linearity error response signal stability
下载PDF
An Atomic Magnetometer with Spin-Projection Noise Proportional to (T_2)^(1/2)
11
作者 Hai-Feng Dong Xiao-Fei Wang +2 位作者 Ji-Min Li Jing-Ling Chen Yuan Ren 《Chinese Physics Letters》 SCIE CAS CSCD 2019年第2期4-7,共4页
There is a comm on sense view for atomic magnetometers that their spin-projection-noises(SPNs) are inversely proportional to (T_2)^(1/2), where (T_2)^(1/2) is the transverse relaxation time. We analyze the current ato... There is a comm on sense view for atomic magnetometers that their spin-projection-noises(SPNs) are inversely proportional to (T_2)^(1/2), where (T_2)^(1/2) is the transverse relaxation time. We analyze the current atomic magnetometer types and give a counter-example of this common sense, which is the all-optical spin precession modulated threeaxis atomic magnetometer proposed by our group in 2015. Unlike the other atomic magnetometers, the SPN of this kind of atomic magnetometers is proportional to (T_2)^(1/2) due to the fact that the scale factor between P_x and B can be unrelated to the transverse relaxation time T_2. We demonstrate this irrelevance experimentally and analyze the SPN theoretically. Using short-pulse ultra-high power laser to fully polarize the atoms, the phenomenon that SPN decreases with T_2 may also be demonstrated experimentally and a new tool for researching SPN in atomic magnetometers may be realized. 展开更多
关键词 AN atomic magnetometer with Spin-Projection Noise Proportional to T2
下载PDF
Atomic magnetometer with microfabricated vapor cells based on coherent population trapping
12
作者 Xiaojie Li Yue Shi +2 位作者 Hongbo Xue Yong Ruan Yanying Feng 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第3期215-219,共5页
An atomic magnetometer based on coherent population trapping(CPT) resonances in microfabricated vapor cells is demonstrated. Fabricated by the micro-electro-mechanical-system(MEMS) technology, the cells are filled wit... An atomic magnetometer based on coherent population trapping(CPT) resonances in microfabricated vapor cells is demonstrated. Fabricated by the micro-electro-mechanical-system(MEMS) technology, the cells are filled with Rb and Ne at a controlled pressure. An experimental apparatus is built for characterizing properties of microfabricated vapor cells via the CPT effects. The typical CPT linewidth is measured to be about 3 k Hz(1.46 k Hz with approximately zero laser intensity) for the rubidium D1 line at about 90℃. The effects of pressure, temperature and laser intensity on CPT linewidth are studied experimentally. A closed-loop atomic magnetometer is finally finished with a sensitivity of 210.5 p T/Hz1/2 at 1 Hz bandwidth. This work paves the way for developing an integrated chip-scale atomic magnetometer in the future. 展开更多
关键词 atomic magnetometer MEMS vapor cell coherent population trapping
下载PDF
Dead-zone-free atomic magnetometer based on hybrid Poincarébeams
13
作者 KE TIAN WEIFENG DING ZHAOYING WANG 《Photonics Research》 SCIE EI CAS CSCD 2024年第5期1093-1097,共5页
In this paper,we present the experiment and the theory scheme of light-atom interaction in atomic magnetometers by using a hybrid Poincarébeam(HPB)to solve an annoying problem,named“dead zone.”This kind of magn... In this paper,we present the experiment and the theory scheme of light-atom interaction in atomic magnetometers by using a hybrid Poincarébeam(HPB)to solve an annoying problem,named“dead zone.”This kind of magnetometer can be sensitive to arbitrary directions of external magnetic fields.The HPB has a complex polarization distribution,consisting of a vector radially polarized beam and a scalar circularly polarized beam in our experiment.These two kinds of beams have different directions of dead zones of external magnetic fields;thereby,the atomic magnetometer with an HPB can avoid the non-signal area when the direction of the external magnetic field is in the plane perpendicular to the light polarization plane.Furthermore,the optical magnetic resonance(OMR)signal using an HPB still has no dead zones even when the direction of the external magnetic field is in the plane parallel to the polarization plane in our scheme.Our work has the potential to simplify and optimize dead-zone-free atomic magnetometers. 展开更多
关键词 POINCARÉ magnetometer atomic
原文传递
Miniature quad-channel spin-exchange relaxation-free magnetometer for magnetoencephalography 被引量:6
14
作者 Jian-Jun Li Peng-Cheng Du +3 位作者 Ji-Qing Fu Xu-Tong Wang Qing Zhou Ru-Quan Wang 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第4期145-149,共5页
A miniature quad-channel optically pumped atomic magnetometer(OPM) has been developed based on the spinexchange relaxation-free(SERF) mechanism. With a vapor cell of size 8 mm×8 mm×8 mm, we have incorporated... A miniature quad-channel optically pumped atomic magnetometer(OPM) has been developed based on the spinexchange relaxation-free(SERF) mechanism. With a vapor cell of size 8 mm×8 mm×8 mm, we have incorporated four SERF magnetometer channels, which provides sufficient spatial resolution for magnetoencephalography(MEG). The four channels share the same laser beam for the best cancellation of common mode noise due to laser fluctuations. With gradient measurement, the sensitivities of the four sensors are better than 6 fT/Hz^(1/2), which is also good enough for MEG measurement. The vapor cell is heated to 160℃ by a novel nonmagnetic current-heating structure. Our sensor with high spatial resolution and compact size is particularly suitable for MEG systems. 展开更多
关键词 multi-channel SPIN-EXCHANGE relaxation-free optically PUMPED atomic magnetometer magne-toencephalography
下载PDF
Spin dynamics of the potassium magnetometer in spin-exchange relaxation free regime 被引量:2
15
作者 伏吉庆 杜鹏程 +1 位作者 周庆 王如泉 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第1期436-439,共4页
The laser-pumped potassium spin-exchange relaxation free (SERF) magnetometer is the most sensitive detector of magnetic field and has many important applications. We present the experimental results of our potassium... The laser-pumped potassium spin-exchange relaxation free (SERF) magnetometer is the most sensitive detector of magnetic field and has many important applications. We present the experimental results of our potassium SERF magne- tometer. A pump-probe approach is used to identify the unique spin dynamics of the atomic ensemble in the SERF regime. A single channel sensitivity of 8 f.THz-1/2 is achieved with our SERF magnetometer. 展开更多
关键词 Larmor process spin-exchange relaxation free magnetometer atomic magnetometer
下载PDF
Influence of pump intensity on atomic spin relaxation in a vapor cell 被引量:1
16
作者 Chen Yang Guan-Hua Zuo +2 位作者 Zhuang-Zhuang Tian Yu-Chi Zhang Tian-Cai Zhang 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第11期339-343,共5页
Atomic spin relaxation in a vapor cell, which can be characterized by the magnetic resonance linewidth(MRL),is an important parameter that eventually determines the sensitivity of an atomic magnetometer. In this paper... Atomic spin relaxation in a vapor cell, which can be characterized by the magnetic resonance linewidth(MRL),is an important parameter that eventually determines the sensitivity of an atomic magnetometer. In this paper, we have extensively studied how the pump intensity affects the spin relaxation. The experiment is performed with a cesium vapor cell, and the influence of the pump intensity on MRL is measured at room temperature at zero-field resonance. A simple model with five atomic levels of a Λ-like configuration is discussed theoretically, which can be used to represent the experimental process approximately, and the experimental results can be explained to some extent. Both the experimental and the theoretical results show a nonlinear broadening of the MRL when the pump intensity is increasing. The work helps to understand the mechanism of pump induced atomic spin relaxation in the atomic magnetometers. 展开更多
关键词 atomic magnetometer atomic SPIN RELAXATION optical PUMPING
下载PDF
Coherent population trapping magnetometer by differential detecting magneto–optic rotation effect 被引量:2
17
作者 张樊 田原 +1 位作者 张奕 顾思洪 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第9期355-358,共4页
A pocket coherent population trapping(CPT) atomic magnetometer scheme that uses a vertical cavity surface emitting laser as a light source is proposed and experimentally investigated.Using the differential detecting... A pocket coherent population trapping(CPT) atomic magnetometer scheme that uses a vertical cavity surface emitting laser as a light source is proposed and experimentally investigated.Using the differential detecting magneto–optic rotation effect,a CPT spectrum with the background canceled and a high signal-to-noise ratio is obtained.The experimental results reveal that the sensitivity of the proposed scheme can be improved by half an order,and the ability to detect weak magnetic fields is extended one-fold.Therefore,the proposed scheme is suited to realize a pocket-size CPT magnetometer. 展开更多
关键词 coherent population trapping atomic magnetometer magneto–optic rotation effect
下载PDF
In-situ measurement of magnetic field gradient in a magnetic shield by a spin-exchange relaxation-free magnetometer
18
作者 房建成 王涛 +2 位作者 张红 李阳 蔡洪炜 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第6期253-258,共6页
A method of measuring in-situ magnetic field gradient is proposed in this paper. The magnetic shield is widely used in the atomic magnetometer. However, there is magnetic field gradient in the magnetic shield, which w... A method of measuring in-situ magnetic field gradient is proposed in this paper. The magnetic shield is widely used in the atomic magnetometer. However, there is magnetic field gradient in the magnetic shield, which would lead to additional gradient broadening. It is impossible to use an ex-situ magnetometer to measure magnetic field gradient in the region of a cell, whose length of side is several centimeters. The method demonstrated in this paper can realize the in-situ measurement of the magnetic field gradient inside the cell, which is significant for the spin relaxation study. The magnetic field gradients along the longitudinal axis of the magnetic shield are measured by a spin-exchange relaxation-free (SERF) magnetometer by adding a magnetic field modulation in the probe beam's direction. The transmissivity of the cell for the probe beam is always inhomogeneous along the pump beam direction, and the method proposed in this paper is independent of the intensity of the probe beam, which means that the method is independent of the cell's transmissivity. This feature makes the method more practical experimentally. Moreover, the AC-Stark shift can seriously degrade and affect the precision of the magnetic field gradient measurement. The AC-Stark shift is suppressed by locking the pump beam to the resonance of potassium's D1 line. Furthermore, the residual magnetic fields are measured with σ+- and σ--polarized pump beams, which can further suppress the effect of the AC-Stark shift. The method of measuring in-situ magnetic field gradient has achieved a magnetic field gradient precision of better than 30 pT/mm. 展开更多
关键词 spin-exchange relaxation-free atomic magnetometer magnetic field gradient magnetic shield AC-Stark shift
下载PDF
Fast In-Situ Triaxial Remanent Magnetic Field Measurement for Single-Beam SERF Atomic Magnetometer Based on Trisection Algorithm
19
作者 Tengyue LONG Bangcheng HAN +2 位作者 Xinda SONG Yuchen SUO Le JIA 《Photonic Sensors》 SCIE EI CSCD 2023年第3期77-89,共13页
We demonstrate a method for quickly and automatically detecting all three components of a remanent magnetic field around a shielded spin-exchange relaxation-free(SERF)atomic magnetometer(AM)using the trisection algori... We demonstrate a method for quickly and automatically detecting all three components of a remanent magnetic field around a shielded spin-exchange relaxation-free(SERF)atomic magnetometer(AM)using the trisection algorithm(TSA)for zero-field resonance(ZFR).To satisfy the measurement of AMs,a resonance light of the ^(87)Rb D1 line with a spectral width of less than 1 MHz is converted to circular polarization by a linear polarizer and a quarter-wave plate.After the light beam has passed through the alkali metal vapor cell,the residual magnetic field can be measured by searching for triaxial ZFR optical peaks.The TSA stably reduces the measurement time to 2.41 s on average and improves the measurement accuracy,significantly outpacing existing methods.The weighted averages of all measurements with corresponding uncertainties are(–15.437±0.022)nT,(6.062±0.021)nT,and(–14.158±0.052)nT on the x-,y-,and z-axes,respectively.These improvements could facilitate more extremely weak magnetic studies in real time,such as magnetoencephalography(MEG)and magnetocardiography(MCG)measurements. 展开更多
关键词 atomic magnetometer remanent magnetic field measurement spin-exchange relaxation free trisection algorithm
原文传递
基于小型化原子磁力计的零场NMR波谱仪搭建与测试
20
作者 付方跃 郭清乾 +5 位作者 冯晓宇 徐佳玉 姚泽坤 胡涛 杨晓冬 常严 《波谱学杂志》 CAS 2024年第1期87-98,共12页
常规高场NMR波谱仪依托超导技术,其体积大、维护成本高,且存在样本磁化率不均匀导致的谱线展宽现象,零场或近零场NMR技术则可实现有效互补.本文自主搭建了一套基于小型原子磁力计的可移动零场NMR波谱仪,采用以多功能采集卡(National Ins... 常规高场NMR波谱仪依托超导技术,其体积大、维护成本高,且存在样本磁化率不均匀导致的谱线展宽现象,零场或近零场NMR技术则可实现有效互补.本文自主搭建了一套基于小型原子磁力计的可移动零场NMR波谱仪,采用以多功能采集卡(National Instruments PCIe-6353)为核心的集成控制系统,仪器主磁场强度小于1nT,可实现高分辨率的J-耦合谱采集.为实现对自旋体系的有效操控,利用样品绝热初态的单脉冲激发实现对三轴脉冲线圈的精确标定.在此基础上,使用改进的组合脉冲序列实现了在^(13)C-^(1)H异核体系下的单自旋选择性操控,验证了零场NMR波谱仪的有效性. 展开更多
关键词 零场核磁共振 J-耦合谱 原子磁力计 单自旋操控
下载PDF
上一页 1 2 8 下一页 到第
使用帮助 返回顶部