期刊文献+
共找到418篇文章
< 1 2 21 >
每页显示 20 50 100
Development of a toroidal soft x-ray imaging system and application for investigating three-dimensional plasma on J-TEXT
1
作者 赵传旭 李建超 +9 位作者 张晓卿 王能超 丁永华 杨州军 江中和 严伟 李杨波 毛飞越 任正康 the J-TEXT Team 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第3期94-99,共6页
A toroidal soft x-ray imaging(T-SXRI)system has been developed to investigate threedimensional(3D)plasma physics on J-TEXT.This T-SXRI system consists of three sets of SXR arrays.Two sets are newly developed and locat... A toroidal soft x-ray imaging(T-SXRI)system has been developed to investigate threedimensional(3D)plasma physics on J-TEXT.This T-SXRI system consists of three sets of SXR arrays.Two sets are newly developed and located on the vacuum chamber wall at toroidal positionsφof 126.4°and 272.6°,respectively,while one set was established previously atφ=65.50.Each set of SXR arrays consists of three arrays viewing the plasma poloidally,and hence can be used separately to obtain SXR images via the tomographic method.The sawtooth precursor oscillations are measured by T-SXRI,and the corresponding images of perturbative SXR signals are successfully reconstructed at these three toroidal positions,hence providing measurement of the 3D structure of precursor oscillations.The observed 3D structure is consistent with the helical structure of the m/n=1/1 mode.The experimental observation confirms that the T-SXRI system is able to observe 3D structures in the J-TEXT plasma. 展开更多
关键词 SXR imaging J-TEXT tokamak three-dimensional measurement MHD
下载PDF
Volumetric measurement techniques for assessment of cutaneous neurofibromas:A review
2
作者 Xinyu Wang Jiayi Xu +2 位作者 Yun Zhu Chengjiang Wei Zhichao Wang 《Chinese Journal of Plastic and Reconstructive Surgery》 2024年第2期83-86,共4页
Cutaneous neurofibroma(cNF)is a prevalent clinical manifestation of neurofibromatosis type 1,significantly affecting the well-being and quality of life of the affected individuals.The adoption of reliable and reproduc... Cutaneous neurofibroma(cNF)is a prevalent clinical manifestation of neurofibromatosis type 1,significantly affecting the well-being and quality of life of the affected individuals.The adoption of reliable and reproducible volumetric measurement techniques is essential for precisely evaluating tumor burden and plays a critical role in the development of effective treatments for cNF.This study focuses on widely used volumetric measurement techniques,including vernier calipers,ultrasound,computed tomography,magnetic resonance imaging,and three-dimensional scanning imaging.It outlines the merits and drawbacks of each technique in assessing the cNF load,providing an overview of their current applications and ongoing research advancements in this domain. 展开更多
关键词 Cutaneous neurofibroma Tumor volume measurement Vernier caliper Ultrasound Computed tomography Magnetic resonance imaging three-dimensional scanning imaging
下载PDF
Multi-objective strategy to optimize dithering technique for high-quality three-dimensional shape measurement 被引量:2
3
作者 Ning Cai Zhe-Bo Chen +1 位作者 Xiang-Qun Cao Bin Lin 《Chinese Physics B》 SCIE EI CAS CSCD 2019年第10期381-386,共6页
Dithering optimization techniques can be divided into the phase-optimized technique and the intensity-optimized technique. The problem with the former is the poor sensitivity to various defocusing amounts, and the pro... Dithering optimization techniques can be divided into the phase-optimized technique and the intensity-optimized technique. The problem with the former is the poor sensitivity to various defocusing amounts, and the problem with the latter is that it cannot enhance phase quality directly nor efficiently. In this paper, we present a multi-objective optimization framework for three-dimensional(3D) measurement by utilizing binary defocusing technique. Moreover, a binary patch optimization technique is used to solve the time-consuming issue of genetic algorithm. It is demonstrated that the presented technique consistently obtains significant phase performance improvement under various defocusing amounts. 展开更多
关键词 three-dimensional(3D) SHAPE measurement MULTI-OBJECTIVE dithering GENETIC algorithm
下载PDF
Evaluating the contribution of satellite measurements to the reconstruction of three-dimensional ocean temperature fields in combination with Argo profiles 被引量:1
4
作者 Jian Chen Hengqian Yan +3 位作者 Senliang Bao Xindong Cui Chengzu Bai Huizan Wang 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2022年第2期65-79,共15页
Assimilation systems absorb both satellite measurements and Argo observations.This assimilation is essential to diagnose and evaluate the contribution from each type of data to the reconstructed analysis,allowing for ... Assimilation systems absorb both satellite measurements and Argo observations.This assimilation is essential to diagnose and evaluate the contribution from each type of data to the reconstructed analysis,allowing for better configuration of assimilation parameters.To achieve this,two comparative reconstruction schemes were designed under the optimal interpolation framework.Using a static scheme,an in situ-only field of ocean temperature was derived by correcting climatology with only Argo profiles.Through a dynamic scheme,a synthetic field was first derived from only satellite sea surface height and sea surface temperature measurements through vertical projection,and then a combined field was reconstructed by correcting the synthetic field with in situ profiles.For both schemes,a diagnostic iterative method was performed to optimize the background and observation error covariance statics.The root mean square difference(RMSD)of the in situ-only field,synthetic field and combined field were analyzed toward assimilated observations and independent observations,respectively.The rationale behind the distribution of RMSD was discussed using the following diagnostics:(1)The synthetic field has a smaller RMSD within the global mixed layer and extratropical deep waters,as in the Northwest Pacific Ocean;this is controlled by the explained variance of the vertical surface-underwater regression that reflects the ocean upper mixing and interior baroclinicity.(2)The in situ-only field has a smaller RMSD in the tropical upper layer and at midlatitudes;this is determined by the actual noise-to-signal ratio of ocean temperature.(3)The satellite observations make a more significant contribution to the analysis toward independent observations in the extratropics;this is determined by both the geographical feature of the synthetic field RMSD(smaller at depth in the extratropics)and that of the covariance correlation scales(smaller in the extratropics). 展开更多
关键词 satellite measurements ARGO three-dimensional reconstruction ocean temperature
下载PDF
Three-Dimensional Measurement and Reconstruction of Fabric Drape Shape 被引量:1
5
作者 沈毅 尹红媛 刘玄木 《Journal of Donghua University(English Edition)》 EI CAS 2007年第1期39-42,共4页
This paper introduces a new method of measuring the three-dimensional drape shape of fabrics with structural light. First, we apply parallel annular structural light to form light and shade alternating contour stripes... This paper introduces a new method of measuring the three-dimensional drape shape of fabrics with structural light. First, we apply parallel annular structural light to form light and shade alternating contour stripes on the surface of fabrics. We then collect the images of contour stripes using Charge Coupled Device (CCD). Subsequently, we process the images to identify the contour stripes and edges of fabrics, and obtain the fabric contour lines of curved surfaces. Finally, we apply three-dimensional curved surface modeling method based on a network of polar coordinates, and reconstruct the three-dimensional drape shape of fabrics. Experiments show that our method is effective in testing and reconstructing three-dimensional drape shape of fabrics. 展开更多
关键词 fabric drape non-contact measurement structurelight image process three-dimension reconstruction.
下载PDF
Deflection Measurement for Bridges Based on Secant Inclination 被引量:1
6
作者 Yi Wu Jing Li 《Open Journal of Civil Engineering》 2021年第4期427-433,共7页
Deflection is a significant indicator of bridge’s strength and its whole stiffness, so the research on deflection measurement is an important aspect of bridge health monitoring. There have existed many measurement me... Deflection is a significant indicator of bridge’s strength and its whole stiffness, so the research on deflection measurement is an important aspect of bridge health monitoring. There have existed many measurement methods of bridge deflection so far, while inclination method is gradually catching more and more attention for its fair obviously comprehensive advantages. However, the inclination method at present focuses on measuring the rotation of bridge’s section at testing point, that is, the tangent angle of deflection curve. With the tangent angle, the deflection curve can be determined by the methods of curve fitting or (and) integration or conjugate beam. The methods mentioned above, are not only complicated in calculation, but also bad in accuracy. The deflection measurement method proposed by this paper is based on measuring the inclination of two points initiatively in horizontal line, that is, the secant angle of the deflection curve, and on the simple triangle function operation. The proposed method is simple in theory, but good in accuracy for either static or dynamic load. The numerical simulation suggests that the error of the proposed method is less than 1%. 展开更多
关键词 BRIDGE deflection INCLINATION SECANT measurement
下载PDF
A method for phase reconstruction in optical three-dimensional shape measurement
7
作者 乔闹生 贺志 《Chinese Physics B》 SCIE EI CAS CSCD 2012年第9期267-270,共4页
In optical three-dimensional shape measurement, a method of improving the measurement precision for phase reconstruction without phase unwrapping is analyzed in detail. Intensities of any five consecutive pixels that ... In optical three-dimensional shape measurement, a method of improving the measurement precision for phase reconstruction without phase unwrapping is analyzed in detail. Intensities of any five consecutive pixels that lie in the x-axis direction of the phase domain are given. Partial derivatives of the phase function in the x- and y-axis directions are obtained with a phase-shifting mechanism, the origin of which is analysed. Furthermore, to avoid phase unwrapping in the phase reconstruction, we derive the gradient of the phase function and perform a two-dimensional integral along the x- and y-axis directions. The reconstructed phase can be obtained directly by performing numerical integration, and thus it is of great convenience for phase reconstruction. Finally, the results of numerical simulations and practical experiments verify the correctness of the proposed method. 展开更多
关键词 phase reconstruction optical three-dimensional shape measurement measurement pre-cision
下载PDF
A fast and precise three-dimensional measurement system based on multiple parallel line lasers
8
作者 Yao Wang Bin Lin 《Chinese Physics B》 SCIE EI CAS CSCD 2021年第2期276-284,共9页
This paper conducts a trade-off between efficiency and accuracy of three-dimensional(3 D)shape measurement based on the triangulation principle,and introduces a flying and precise 3 D shape measurement method based on... This paper conducts a trade-off between efficiency and accuracy of three-dimensional(3 D)shape measurement based on the triangulation principle,and introduces a flying and precise 3 D shape measurement method based on multiple parallel line lasers.Firstly,we establish the measurement model of the multiple parallel line lasers system,and introduce the concept that multiple base planes can help to deduce the unified formula of the measurement system and are used in simplifying the process of the calibration.Then,the constraint of the line spatial frequency,which maximizes the measurement efficiency while ensuring accuracy,is determined according to the height distribution of the object.Secondly,the simulation analyzing the variation of the systemic resolution quantitatively under the circumstance of a set of specific parameters is performed,which provides a fundamental thesis for option of the four system parameters.Thirdly,for the application of the precision measurement in the industrial field,additional profiles are acquired to improve the lateral resolution by applying a motor to scan the 3 D surface.Finally,compared with the line laser,the experimental study shows that the present method of obtaining 41220 points per frame improves the measurement efficiency.Furthermore,the accuracy and the process of the calibration are advanced in comparison with the existing multiple-line laser and the structured light makes an accuracy better than 0.22 mm at a distance of 956.02 mm. 展开更多
关键词 three-dimensional shape measurement multiple parallel line lasers fast and precise measurement parameter calibration
下载PDF
Three-Dimensional Velocity Distribution Measurement Using Ultrasonic Velocity Profiler with Developed Transducer
9
作者 Naruki Shoji Hiroshige Kikura +1 位作者 Hideharu Takahashi Wongsakorn Wongsaroj 《Journal of Flow Control, Measurement & Visualization》 2022年第1期32-55,共24页
This study describes an ultrasonic velocity profiler that uses a <span style="white-space:normal;"><span style="font-family:;" "="">new ultrasonic array transducer with u... This study describes an ultrasonic velocity profiler that uses a <span style="white-space:normal;"><span style="font-family:;" "="">new ultrasonic array transducer with unique 5-element configuration</span></span><span style="white-space:normal;"><span style="font-family:;" "="">, with all five elements acting as transmitters and four elements as receivers. The receivers are designed to reduce the amount of uncertainty. As the fluid moves through this setup, four Doppler frequencies are obtained. The multi-dimensional velocity information along the measurement line can be reconstructed. The transducer has a compact geometry suitable for a wide range of applications, including narrow flow areas. The transducer’s basic frequency and sound pressure are selected and evaluated to be compatible with the application. First, to confirm the measurement ability, the measurement of the developed system in two-dimensional flow is validated by comparing it to the theoretical data. The uncertainty of measurement was within 15%. Second, the three-dimensional measurement in turbulent and swirling flow is proved experimentally to check the applicability of the proposed technique.</span></span> 展开更多
关键词 Doppler Frequency Liquid Velocity three-dimensional measurement Transducer Design ULTRASONIC
下载PDF
Digital measurement of bone tumor volume by CT three-dimensional reconstruction technology
10
作者 胡永成 《外科研究与新技术》 2011年第2期125-125,共1页
Objective To discuss the measurement of bone tumor volume on the basis of three dimensional images segmentation technology. Methods Twenty patients with lacunar bone tumor from Tianjin Hospital and Tongji Hospital wer... Objective To discuss the measurement of bone tumor volume on the basis of three dimensional images segmentation technology. Methods Twenty patients with lacunar bone tumor from Tianjin Hospital and Tongji Hospital were included in the 展开更多
关键词 BONE Digital measurement of bone tumor volume by CT three-dimensional reconstruction technology CT
下载PDF
Three-Dimensional Analytical Modeling of Axial-Flux Permanent Magnet Drivers
11
作者 Wenhui Li Dazhi Wang +3 位作者 Shuo Cao Deshan Kong Sihan Wang Zhong Hua 《Computers, Materials & Continua》 SCIE EI 2023年第4期259-276,共18页
In this paper, the axial-flux permanent magnet driver is modeledand analyzed in a simple and novel way under three-dimensional cylindricalcoordinates. The inherent three-dimensional characteristics of the deviceare co... In this paper, the axial-flux permanent magnet driver is modeledand analyzed in a simple and novel way under three-dimensional cylindricalcoordinates. The inherent three-dimensional characteristics of the deviceare comprehensively considered, and the governing equations are solved bysimplifying the boundary conditions. The axial magnetization of the sectorshapedpermanent magnets is accurately described in an algebraic form bythe parameters, which makes the physical meaning more explicit than thepurely mathematical expression in general series forms. The parameters of theBessel function are determined simply and the magnetic field distribution ofpermanent magnets and the air-gap is solved. Furthermore, the field solutionsare completely analytical, which provides convenience and satisfactoryaccuracy for modeling a series of electromagnetic performance parameters,such as the axial electromagnetic force density, axial electromagnetic force,and electromagnetic torque. The correctness and accuracy of the analyticalmodels are fully verified by three-dimensional finite element simulations and a15 kW prototype and the results of calculations, simulations, and experimentsunder three methods are highly consistent. The influence of several designparameters on magnetic field distribution and performance is studied and discussed.The results indicate that the modeling method proposed in this papercan calculate the magnetic field distribution and performance accurately andrapidly, which affords an important reference for the design and optimizationof axial-flux permanent magnet drivers. 展开更多
关键词 three-dimensional analytical modeling cylindrical coordinates magnetic field distribution parameter sensitivity analysis performance measurement
下载PDF
Development of a Three-Dimensional Measuring System for Neonates' Head and Facial Morphology 被引量:1
12
作者 邓咏梅 易洁伦 +2 位作者 郭绮莲 黄小珍 吴新培 《Journal of Donghua University(English Edition)》 EI CAS 2007年第3期309-312,共4页
A web camera based multi-camera convergent close-range photogrammetric system is developed to obtain the neonates' head and facial morphology. The data will then be used to develop a secure and good-fitting eye-patch... A web camera based multi-camera convergent close-range photogrammetric system is developed to obtain the neonates' head and facial morphology. The data will then be used to develop a secure and good-fitting eye-patch protector for neonates, particularly whoa they are exposed to bright lights such as phototherapy light. Measurements obtained by the system are evaluated and validated against data obtained from optical scanning. Results show that the photogrammetric system meets the requirements of measuring accuracy and safety for neonate in the neonatal units. 展开更多
关键词 close-range photogrammetry (CRP) three-dimensional measurement NEONATES head and facialmorphology
下载PDF
Simulation and Experiment Study on the Bridge Deflection Measuring Method Based on Secant Inclination
13
作者 Yi Wu Jing Li 《Open Journal of Civil Engineering》 CAS 2022年第3期438-450,共13页
Deflection is the most direct indicator that reflects the bearing capacity of the bridge and the overall stiffness. There are many ways to measure the deflection of Bridges, and the inclination angle method is the mos... Deflection is the most direct indicator that reflects the bearing capacity of the bridge and the overall stiffness. There are many ways to measure the deflection of Bridges, and the inclination angle method is the most commonly used indirect method, but the existing theory of inclination angle method is relatively complicated. Based on the facts of the bridge small inclination, this article proposes the method of obtaining the bridge deflection by the inclination of the secant line constructed from the adjacent measurement points. Firstly, according to the bending deformation curve of general simply supported beam, the deflection calculation formula of each measuring point is derived based on the assumption of small deformation and the inclination Angle of measuring point. Secondly, a large commercial finite element software ANSYS 10.0 is used to carry out numerical simulation on the simply-supported beam under concentrated load in mid-span, and the deflection results of the numerical simulation are compared and verified with the theoretical results of the proposed method. Finally, the measured deflection results of the simply-supported beam model under mid-span load are compared with the theoretical results of the proposed method. The verification results show that if the actual model is consistent with the theoretical model, the proposed method has good accuracy. 展开更多
关键词 Bridge deflection measurement INCLINATION Experiment Of deflection measurement
下载PDF
Diameters and form of skull base foramen ovale measured by three-dimensional spiral CT thin-slice scan in healthy adults
14
作者 Xiaohua Chen Fengxian Deng +1 位作者 Shuhang Wei Tingsong Fang 《Neural Regeneration Research》 SCIE CAS CSCD 2006年第4期343-346,共4页
BACKGROUND: The accurate measurements of various data of the bone diameters of foramen ovale of living person can change the methods of puncturing trigeminal gasserian ganglion via foramen ovale for treating trifacia... BACKGROUND: The accurate measurements of various data of the bone diameters of foramen ovale of living person can change the methods of puncturing trigeminal gasserian ganglion via foramen ovale for treating trifacial neuralgia from the experience of puncture operator only to puncture by taking the objective data of measurement as the evidence, which is good for improving the accuracy of puncturing trigeminal ganglion and reducing side effects. OBJECTIVE : To observe the forms of foramen ovales in healthy adults displayed by volume rendering and multi-planar reconstruction after three-dimensional spiral CT thin-slice scan of skull base, and measure the longitudinal diameter and transverse diameter. DESIGN : A repetitive observation and measurement SETTINGS : Department of Neurosurgery and Department of Medical Imaging, Foshan Hospital of Traditional Chinese Medicine. PARTICIPANTS: Fifty healthy adults (100 sides), who were examined with three-dimensional spiral CT scan, were randomly selected from the Department of Medical Imaging, Foshan Hospital of Traditional Chinese Medicine from January 2005 to January 2006, including 26 males and 24 females, aged 25-68 years with an average of 48 years old. They were all informed and agreed with the examination. METHODS : The subjects were examined with the Philips 16-slice spiral CT-Mx 8000 IDT CT apparatus (Philips Company, Holland), the scanning ranged from 2 cm below the canthomeatal line to the level of suprasellar cistem. The width of collimator was 0.75 mm, pitch was 0.663; tube current was 350 mA, voltage was 120 kV, resolution was 512×512 matrix; slice thickness of reconstruction was 1 mm, and interval was 0.5 mm. After the three-dimensional spiral CT thin-slice scan of skull base, the image post-processing techniques including volume rendering and multi-planar reconstruction were applied to observe the forms of foramen ovales, and measure the size, longitudinal diameter and transverse diameter of the foramen ovales. The figures of the foramen ovales were drawn with mouse along the boundary of bone porous margin and soft tissue. According to the indications, the diameters were measured with computer to observe the forms of foramen ovales. MAIN OUTCOME MEASURES : The longitudinal diameter, transverse diameter and form of foramen ovales were observed. RESULTS: All the 50 healthy adults (100 sides) were involved in the analysis of results. (1) It was observed in the volume rendering images that foramen ovales had four forms of oval shape (77 sides), kidney shape (12 sides), round shape (7 sides), ribbon shape (4 sides). (2) The longitudinal diameters of left and right foramen ovales were (7.67±1.32) and (7.98±1.45) mm, and the transverse diameters were (4.04±0.83), (4.09±1.07) mm; There was no obvious difference between left and right longitudinal diameters (t = 1.63, P = 0.11 ), and left and right transverse diameters were close (t = 0.45, P= 0.65). CONCLUSION : The non-invasive techniques of volume rendering and multi-planar reconstruction after three-dimensional spiral CT thin-slice scan can clearly display the formand size of foramen ovale in healthy adults. 展开更多
关键词 Diameters and form of skull base foramen ovale measured by three-dimensional spiral CT thin-slice scan in healthy adults CT base
下载PDF
Development of an In-Situ Laser Machining System Using a Three-Dimensional Galvanometer Scanner 被引量:6
15
作者 Xiao Li Bin Liu +3 位作者 Xuesong Mei Wenjun Wang Xiaodong Wang Xun Li 《Engineering》 SCIE EI 2020年第1期68-76,共9页
In this study, a three-dimensional (3D) in-situ laser machining system integrating laser measurement and machining was built using a 3D galvanometer scanner equipped with a side-axis industrial camera. A line structur... In this study, a three-dimensional (3D) in-situ laser machining system integrating laser measurement and machining was built using a 3D galvanometer scanner equipped with a side-axis industrial camera. A line structured light measurement model based on a galvanometer scanner was proposed to obtain the 3D information of the workpiece. A height calibration method was proposed to further ensure measurement accuracy, so as to achieve accurate laser focusing. In-situ machining software was developed to realize time-saving and labor-saving 3D laser processing. The feasibility and practicability of this in-situ laser machining system were verified using specific cases. In comparison with the conventional line structured light measurement method, the proposed methods do not require light plane calibration, and do not need additional motion axes for 3D reconstruction;thus they provide technical and cost advantages. The insitu laser machining system realizes a simple operation process by integrating measurement and machining,which greatly reduces labor and time costs. 展开更多
关键词 In-situ laser machining three-dimensional galvanometer scanner Line structured light three-dimensional measurement
下载PDF
A comparison of summer precipitation structures over the South China Sea and the East China Sea based on tropical rainfall measurement mission 被引量:3
16
作者 LI Jiangnan YANG Chaofeng +2 位作者 LI Fangzhou HE Qihua LI Weibiao 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2013年第11期41-49,共9页
The three-dimensional structures of summer precipitation over the South China Sea (SCS) and the East China Sea (ECS) are investigated based on tropical rainfall measurement mission (TRMM). The primary results ar... The three-dimensional structures of summer precipitation over the South China Sea (SCS) and the East China Sea (ECS) are investigated based on tropical rainfall measurement mission (TRMM). The primary results are as follows. First, both the convective and stratiform precipitation rates in the SCS are much higher than those of the ECS. The contribution of the convective cloud precipitation to the surface precipitation is primarily over the SCS and the ECS with a proportion of about 70%, but the contribution of convective cloud precipitation is slightly larger in the SCS than the ECS. The contribution of stratus precipitation is slightly larger in the ECS than that in the SCS. Second, the content of cloud particles and precipitation particles in the ECS in June was greater than that in the SCS, while in July and August, the content of cloud and precipitation particles in the ECS was less than that in the SCS. Third, the latent heat profile of the ECS is quite different from that of the SCS. In June, the peak values of evaporation and condensation latent heating rates in the ECS are greater than those in the SCS. In July and August, however, the peak values of evaporation and condensation latent heating rates in the ECS are about 0.05°/h less than those in the SCS. 展开更多
关键词 PRECIPITATION three-dimensional structures tropical rainfall measurement mission SouthChina Sea East China Sea
下载PDF
Three-dimensional experimental study of loose top-coal drawing law for longwall top-coal caving mining technology 被引量:13
17
作者 Jiachen Wang Jinwang Zhang +1 位作者 Zhengyang Song Zhaolong Li 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2015年第3期318-326,共9页
Based on the loose medium flow field theory, the loose top-coal drawing law of longwall top-coal caving(LTCC) mining technology is studied by using self-developed three-dimensional(3D) test device. The loose top-c... Based on the loose medium flow field theory, the loose top-coal drawing law of longwall top-coal caving(LTCC) mining technology is studied by using self-developed three-dimensional(3D) test device. The loose top-coal drawing test with shields and the controlled test without shields are performed in the condition without any boundary effect. Test results show that shields will cause reduction in drawing volume of coal in the LTCC mining. The deflection phenomenon of drawing body is also observed in the controlled test, which is verified that the deflection of drawing body is caused by shield. It is found that the deflection angle decreases with increasing caving height, with the maximum value of atailand the minimum value of 0. In addition, the formula to calculate the drawing volume is proposed subsequently.The deflection of drawing body is numerically simulated using particle flow code PFC3 Dand the proposed formula to calculate drawing volume in LTCC is also verified. 展开更多
关键词 Longwall top-coal caving(LTCC) Caving shield three-dimensional(3D) physical model test deflection of drawing body PFC3D
下载PDF
EXPERIMENTAL INVESTIGATION FOR THE EFFECT OF ROTATION ON THREE-DIMENSIONAL FLOW FIELD IN FILM-COOLED TURBINE 被引量:2
18
作者 YUAN Feng ZHU Xiaocheng DU Zhaohui 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2007年第1期10-15,共6页
An experimental investigation of three-dimensional flow field in a film-cooled turbine model is carried out by using particle image velocimeter (PIV) in a low-speed wind tunnel. The effects of different blowing rati... An experimental investigation of three-dimensional flow field in a film-cooled turbine model is carried out by using particle image velocimeter (PIV) in a low-speed wind tunnel. The effects of different blowing ratios (M=1.5, 2) on the flow field are studied. The experimental results reveal the classical phenomena of the formation of kidney vortex pair and secondary flow in wake region behind the jet hole. And the changes of the kidney vortex pair and the wake at different locations away from the hole on the suction and pressure sides are also studied. Compared with the flow field in stationary cascade, there are centrifugal force and Coriolis force existing in the flow field of rotating turbine, and these forces bring the radial velocity in the jet flow. The effect of rotatien on the flow field of the pressure side is more distinct than that on the suction side from the measured flow fields in Y-Z plane and radial velocity contours. The increase of blowing ratio makes the kidney vortex pair and the secondary flow in the wake region stronger and makes the range of the wake region enlarged. 展开更多
关键词 Film-cooled turbine rotor PIV measurement Blowing ratio three-dimensional flow field
下载PDF
Three-Dimensional Thermo-Elastic-Plastic Finite Element Method Modeling for Predicting Weld-Induced Residual Stresses and Distortions in Steel Stiffened-Plate Structures 被引量:1
19
作者 Myung Su Yi Chung Min Hyun Jeom Kee Paik 《World Journal of Engineering and Technology》 2018年第1期176-200,共25页
The objective of the present paper is to develop nonlinear finite element method models for predicting the weld-induced initial deflection and residual stress of plating in steel stiffened-plate structures. For this p... The objective of the present paper is to develop nonlinear finite element method models for predicting the weld-induced initial deflection and residual stress of plating in steel stiffened-plate structures. For this purpose, three-dimensional thermo-elastic-plastic finite element method computations are performed with varying plate thickness and weld bead length (leg length) in welded plate panels, the latter being associated with weld heat input. The finite element models are verified by a comparison with experimental database which was obtained by the authors in separate studies with full scale measurements. It is concluded that the nonlinear finite element method models developed in the present paper are very accurate in terms of predicting the weld-induced initial imperfections of steel stiffened plate structures. Details of the numerical computations together with test database are documented. 展开更多
关键词 STEEL Stiffened-Plate Structures Weld-Induced Initial Distortion Weld-Induced Residual Stress Nonlinear FINITE ELEMENT Method three-dimensional Ther-mo-Elastic-Plastic FINITE ELEMENT Analysis Full Scale measurements
下载PDF
Multi-Schlieren CT Measurements of Supersonic Microjets from Circular and Square Micro Nozzles 被引量:1
20
作者 Ahmad Zaid Nazari Yojiro Ishino +6 位作者 Yuta Ishiko Fumiya Ito Harumi Kondo Ryoya Yamada Takanori Motohiro Yoshiaki Miyazato Shinichiro Nakao 《Journal of Flow Control, Measurement & Visualization》 2020年第3期77-101,共25页
Instantaneous three-dimensional (3D) density distributions of a shock-cell structure of perfectly and imperfectly expanded supersonic microjets escaping into an ambient space are measured. For the 3D observation of su... Instantaneous three-dimensional (3D) density distributions of a shock-cell structure of perfectly and imperfectly expanded supersonic microjets escaping into an ambient space are measured. For the 3D observation of supersonic microjets, non-scanning 3D computerized tomography (CT) technique using a 20-directional quantitative schlieren optical system with flashlight source is employed for simultaneous schlieren photography. The 3D density distributions data of the microjets are obtained by 3D-CT reconstruction of the projection’s images using maximum likelihood-expectation maximization. Axisymmetric convergent-divergent (Laval) circular and square micro nozzles with operating nozzle pressure ratio 5.0, 4.5, 4.0, 3.67, and 3.5 have been studied. This study examines perfectly expanded, overexpanded, and underexpanded supersonic microjets issued from micro nozzles with fully expanded jet Mach numbers <em>M</em><em><sub>j</sub></em> ranging from 1.47 - 1.71, where the design Mach number is <em>M<sub>d</sub></em> = 1.5. A complex phenomenon for free square microjets called axis switching is clearly observed with two types “upright” and “diagonal” of “cross-shaped”. The initial axis-switching is 45<span style="white-space:nowrap;">°</span> within the first shock-cell range. In addition, from the symmetry and diagonal views of square microjets for the first shock-cells, two different patterns of shock waves are viewed. The shock-cell spacing and supersonic core length for all nozzle pressure ratios are investigated and reported. 展开更多
关键词 Supersonic Microjet Multi-Directional Quantitative Schlieren Optical System three-dimensional (3D) measurement Computerized Tomography (CT) Circular and Square Micro Laval Nozzles
下载PDF
上一页 1 2 21 下一页 到第
使用帮助 返回顶部