BACKGROUND Diabetic cardiomyopathy is considered as a chronic complication of diabetes mellitus(DM).Therefore,early detection of left ventricular systolic function(LVSF)damage in DM is essential.AIM To explore the use...BACKGROUND Diabetic cardiomyopathy is considered as a chronic complication of diabetes mellitus(DM).Therefore,early detection of left ventricular systolic function(LVSF)damage in DM is essential.AIM To explore the use of the three-dimensional speckle tracking technique(3D-STI)for measuring LVSF in DM patients via meta-analysis.METHODS The electronic databases were retrieved from the initial accessible time to 29 April 2023.The current study involved 9 studies,including 970 subjects.We carried out this meta-analysis to estimate myocardial function in DM compared with controls according to myocardial strain attained by 3D-STI.RESULTS Night articles including 970 subjects were included.No significant difference was detected in the left ventricular ejection fraction between the control and the diabetic group(P>0.05),while differences in global longitudinal strain,global circumferential strain,global radial strain,and global area strain were markedly different between the controls and DM patients(all P<0.05).CONCLUSION The 3D-STI could be applied to accurately measure early LVSF damage in patients with DM.展开更多
Objective To evaluate left atrial function in essential hypertension patients with different patterns of left ventricular geometric models by real-time three-dimensional echocardiography (RT-3DE) and left atrial tra...Objective To evaluate left atrial function in essential hypertension patients with different patterns of left ventricular geometric models by real-time three-dimensional echocardiography (RT-3DE) and left atrial tracking (EAT).展开更多
Left ventricular remodeling index (LVRI) was assessed in patients with hypertensive heart disease (HHD) and coronary artery disease (CAD) by real-time three-dimensional echocardiography (RT3DE). RT3DE data of ...Left ventricular remodeling index (LVRI) was assessed in patients with hypertensive heart disease (HHD) and coronary artery disease (CAD) by real-time three-dimensional echocardiography (RT3DE). RT3DE data of 18 patients with HHD, 20 patients with CAD and 22 normal controis (NC) were acquired. Left ventricular end-diastolic volume (EDV) and left ventricular end-diastolic epicardial volume (EDVepi) were detected by RT3DE and two-dimensional echocardiography Simpson biplane method (2DE). LVRI (left ventricular mass/EDV) was calculated and compared. The results showed that LVRI measurements detected by RT3DE and 2DE showed significant differences inter-groups (P〈0.01). There was no significant difference in NC group (P〉0.05), but significant difference in HHD and CAD intra-group (P〈0.05). There was good positive correlations between LVRI detected by RT3DE and 2DE in NC and HHD groups (t=0.69, P〈0.01; r=0.68, P〈0.01), but no significant correlation in CAD group (r=0.30, P〉0.05). It was concluded that LVRI derived from RT3DE as a new index for evaluating left ventricular remodeling can provide more superiority to LVRI derived from 2DE.展开更多
Current guidelines encourage large studies in a diverse population to establish normal reference ranges for three-dimensional(3D)echocardiography for different ethnic groups.This study was designed to establish the no...Current guidelines encourage large studies in a diverse population to establish normal reference ranges for three-dimensional(3D)echocardiography for different ethnic groups.This study was designed to establish the normal values of 3D-left ventricular(LV)and left atrial(LA)volume and function in a nationwide,population-based cohort of healthy Han Chinese adults.A total of 1117 healthy volunteers aged 18–89 years were enrolled from 28 collaborating laboratories in China.Two sets of 3D echocardiographic instruments were used,and full-volume echocardiographic images were recorded and transmitted to a core laboratory for image analysis with a vendor-independent off-line workstation.Finally,866 volunteers(mean age of 48.4 years,402 men)were qualified for final analysis.Most parameters exhibited substantial differences between different sex and age groups,even after indexation by body surface area.The normal ranges of 3D-LV and 3D-LA volume and function differed from those recommended by the American Society of Echocardiography and the European Association of Cardiovascular Imaging guidelines,presented by the World Alliance Societies of Echocardiography(WASE)study,and from the 2D values in the EMINCA study.The normal reference values of 3D echocardiography-derived LV and LA volume and function were established for the first time in healthy Han Chinese adults.Normal ranges of 3D-LV and 3D-LA echocardiographic measurements stratified with sex,age,and race should be recommended for clinical applications.展开更多
To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phanto...To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phantoms made of two rubber-bursas, ten excised canine hearts underwent RT3DE and two-dimensional echocardiography (2DE). In RT3DE "full volume" imaging, the myocardial volume was mea-sured using 2,4,8, and 16-plane method with the analysis software of RT3DE. Mass was then calculated by multiplying the resulting myocardial volume by specific density of myocardial tissue. In 2DE the masses were measured by area-length meth-od. The true LV wall phantom mass was measured by water displacement and the canine LVM was weighed by anatomy, which served as a reference standard. We compared RT3DE or 2DE with true mass. Results In LV wall phantoms, RT3DE correlated with true masses strongly (r = 0.813-0.994) and weakly correlated between 2DE and true masses (r = 0.628). In excised canine hearts, there is an excellent correlation between RT3DE and true masses (r = 0.764-0.991), while 2DE value showed a lesser correlation (r = 0.514). There are no difference between RT-3DE and true masses (P > 0.05) but different between 2DE and true masses (P < 0.05). In different planes, there was no difference between 8-plane and 16-plane (P > 0.05) but different between 8-plane and 2, 4-plane (P < 0.05). Conclusion RT3DE can accurately quantify LVM and provide a new tool to evaluate LV function. For LVM by RT3DE, 8-plane measurement method is the best choice for accuracy and convenience.展开更多
AIM To evaluate the long-term outcome of catheter ablation of atrial fibrillation(AF) facilitated by preprocedural threedimensional(3-D) transesophageal echocardiography.METHODS In 50 patients, 3D transesophageal echo...AIM To evaluate the long-term outcome of catheter ablation of atrial fibrillation(AF) facilitated by preprocedural threedimensional(3-D) transesophageal echocardiography.METHODS In 50 patients, 3D transesophageal echocardiography(3D TEE) was performed immediately prior to an ablation procedure(paroxysmal AF: 30 patients, persistent AF: 20 patients). The images were available throughout the ablation procedure. Two different ablation strategies were used. In most of the patients with paroxysmal AF, the cryoablation technique was used(Arctic Front Balloon, Cryo Cath Technologies/Medtronic; group A2). In the other patients, a circumferential pulmonary vein ablation was performed using the CARTO system [Biosense Webster; group A1(paroxysmal AF), group B(persistent AF)]. Success rates and complication rates were analysed at 4-year follow-up.RESULTS A 3D TEE could be performed successfully in all patients prior to the ablation procedure and all four pulmonaryvein ostia could be evaluated in 84% of patients. The image quality was excellent in the majority of patients and several variations of the pulmonary vein anatomy could be visualized precisely(e.g., common pulmonary vein ostia, accessory pulmonary veins, varying diameter of the left atrial appendage and its distance to the left superior pulmonary vein). All ablation procedures could be performed as planned and almost all pulmonary veins could be isolated successfully. At 48-mo followup, 68.0% of all patients were free from an arrhythmia recurrence(group A1: 72.7%, group A2: 73.7%, group B: 60.0%). There were no major complications.CONCLUSION3 D TEE provides an excellent overview over the left atrial anatomy prior to AF ablation procedures and these procedures are associated with a favourable long-term outcome.展开更多
The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function...The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function was assessed. RV “Full volume” images were acquired by RT3DE in 22 healthy subjects. RV end-diastolic volumes (RVEDV) and end-systolic volumes (RVESV) were outlined using apical biplane, 4-plane, 8-plane, 16-plane offline separately. RVSV and RVEF were calculated. Meanwhile tricuspid annual systolic excursion (TASE) was measured by M-mode echo. LVSV was outlined by 2-D echo according to the biplane Simpson's rule. The results showed: (1) There was a good correlation between RVSV measured from series planes and LVSV from 2-D echo (r=0.73; r=0.69; r=0.63; r=0.66, P<0.25—0.0025); (2) There were significant differences between RVEDV in biplane and those in 4-, 8-, 16-plane (P<0.001). There was also difference between RV volume in 4-plane and that in 8-plane (P<0.05), but there was no significant difference between RV volume in 8-plane and that in 16-plane (P>0.05); (3) Inter-observers and intro-observers variability analysis showed that there were close agreements and relations for RV volumes (r=0.986, P<0.001; r=0.93, P<0.001); (4) There was a significantly positive correlation of TASE to RVSV and RVEF from RT3DE (r=0.83; r=0.90). So RV volume measures with RT3DE are rapid, accurate and reproducible. In view of RV's complex shape, apical 8-plane method is better in clinical use. It may allow early detection of RV systolic function.展开更多
BACKGROUND The anthracycline chemotherapeutic drugs are cardiotoxic.Studies have found some indicators related to cardiotoxicity.However,there is currently no accurate indicator that can predict cardiac toxicity early...BACKGROUND The anthracycline chemotherapeutic drugs are cardiotoxic.Studies have found some indicators related to cardiotoxicity.However,there is currently no accurate indicator that can predict cardiac toxicity early.AIM To explore the diagnostic value of real-time three-dimensional echocardiography(RT3DE)in predicting cardiac toxicity in breast cancer patients undergoing chemotherapy.METHODS Female breast cancer patients who underwent radical mastectomy and postoperative chemotherapy at the Affiliated Hanzhou First People’s Hospital,Zhejiang University School of Medicine were recruited.All patients were routinely administered with chemotherapy for four cycles(T1-T4)after surgery.Two-dimensional(2D)echocardiography,RT3DE,and serological examinations were performed after each cycle of chemotherapy.Patients were divided into a toxic group and a non-toxic group based on whether patients hadΔleft ventricular ejection fraction>10%after one year of chemotherapy.Repeated measurement analysis of variance was used to compare the changes in 2D echocardiographic indicators,serological indicators,and RT3DE indicators before independent predictive indicators for cardiac toxicity in postoperative chemotherapy patients.Receiver operating characteristics(ROC)curve analysis was performed to analyze the diagnostic value of potential indicators in the diagnosis of cardiotoxicity.RESULTS A total of 107 female breast cancer patients were included in the study.T4 maximum peak velocity in early diastole(E peak)/mitral annulus lateral tissue Doppler(e'peak)(E/e'),serological indicators[T4 cardiac troponin I(cTnI)and T4 pro-brain natriuretic peptide(Pro-BNP)],T3 minimum left atrial volume(LAV),T4 LAVmin,T3 LAV before the start of the P wave(LAVprep),and T4 LAVprep in the toxicity group were significantly higher than those in the nontoxic group.Multivariate logistic regression found that T4 cTnI,T4 Pro-BNP,T3 LAVmin,T4 LAVmin,T3 LAVprep,and T4 LAVprep had potential predictive value for cardiac toxicity(P<0.05).ROC results showed that T4 LAVmin had the highest accuracy for diagnosing cardiac toxicity[area under the curve(AUC)=0.947;sensitivity=78.57%;specificity=94.62%],followed by T4 LAVprep(AUC=0.899;sensitivity=100%;specificity=66.67%).The accuracies of LAVprep and LAVprep in predicting cardiac toxicity were higher than those of T3 LAVmin and T3 LAVprep.CONCLUSION RT3DE of left atrial volume can be used to predict the cardiotoxicity caused by chemotherapy,and it is expected to guide the clinical adjustment of dose and schedule in time.展开更多
Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed...Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed in 21 open-chest mongrel dogs undergoing acute ligation of the left anterior descending artery (LAD, n=14) or distal branch of the left circumflex artery (LCX, n=7). A perfluorocarbon microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with Philips Sonos-7500 ultrasound system. Evans blue dye was injected into the occluded coronary artery for subsequent anatomic identification of underperfused myocardium. In vitro anatomic measurement of myocardial mass after removal of the animal’s heart was regarded as the control. Blinded off-line calculation of left ventricular mass and perfusion defect mass from RT3DE images were performed using an interactive aided-manual tracing technique.Results Total left ventricular (LV) myocardial mass ranged from 38.9 to 78.5 (mean±SD: 60.0±10.1) g. The mass of perfusion defect ranged from 0 to 21.4 (mean±SD: 12.0±5.0) g or 0 to 27% of total LV mass (mean±SD: 19%±6%). The RT3DE estimation of total LV mass (mean±SD: 59.8±9.9 g) strongly correlated with the anatomic measurement (r=0.98; y=2.01+0.96x). The CE-RT3DE calculation of the mass of underperfused myocardium (mean±SD: 12.3±5.3 g) also strongly correlated with the anatomic measurement (r=0.96; y=-0.10+1.04x) and when expressed as percentage of total LV mass (r=0.95; y=-0.20+1.04x). Conclusions RT3DE with myocardial contrast opacification could accurately estimate underperfused myocardial mass in dogs of acute coronary occlusion and would play an important role in quantitative assessment of myocardial perfusion defects in patients with coronary artery disease.展开更多
The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical find...The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical findings. Two-dimensional and real-time three dimensional echocardiography (RT3DE) was performed in 26 patients with atrial septal defect, and the echocardiographic data were compared with the surgical findings. Significant correlation was found between defect diameter by RT3DE and that measured during surgery (r=0.77, P〈0.001). The defect area changed significantly during cardiac cycle. Percentage change in defect size during cardiac cycle ranged from 6%-70%. Our study showed that the size and morphology of atrial septal defect obtained with RT3DE correlate well with surgical findings. Therefore, RT3DE is a feasible and accurate non-invasive imaging tool for assessment of atrial septal size and dynamic changes.展开更多
Objective:To establish a quantitative evaluation of the left ventricle's systolic function in patients with chronic kidney failure(CKF)by three-dimensional speckle-tracking echocardiography.Methods:Two-dimensional...Objective:To establish a quantitative evaluation of the left ventricle's systolic function in patients with chronic kidney failure(CKF)by three-dimensional speckle-tracking echocardiography.Methods:Two-dimensional and three-dimensional transthoracic echocardiography was performed on 30 patients with CKF.The ejection fraction,mass and global peak longitudinal strain,global circumferential strain,global area strain,and global radial strain of the left ventricle were calculated.Results:The ejection fraction,mass and global peak longitudinal strain(GLS),global circumferential strain(GCS),global area strain(GAS),and global radial strain(GRS)in the CKF group were significantly lower than those in the control group.Simultaneously,the GLS,GCS,GAS and GRS were well correlated with the ejection fraction.For patients with normal ejection fraction in the CKF group,the GLS,GCS,GAS and GRS were lower than those in the control group,while the left ventricular mass was significantly higher in CKF patients than in the control group.For patients with hypertension in the CKF group,ejection fraction,GLS,GCS,GAS and GRS calculated using three-dimensional echocardiography were significantly lower than those in patients with normal blood pressure;however,the myocardial mass was higher.Conclusions:The parameters(GLS,GCS,GAS and GRS)calculated using three-dimensional speckle-tracking software were lower in the CKF group.Simultaneously,the left ventricular mass was higher in CFK patients than in the control group,thus showing that the myocardial contraction function was impaired and that myocardial remodeling had occurred.展开更多
BACKGROUND HeartModel(HM)is a fully automated adaptive quantification software that can quickly quantify left heart volume and left ventricular function.This study used HM to quantify the left ventricular end-diastoli...BACKGROUND HeartModel(HM)is a fully automated adaptive quantification software that can quickly quantify left heart volume and left ventricular function.This study used HM to quantify the left ventricular end-diastolic(LVEDV)and end-systolic volumes(LVESV)of patients with dilated cardiomyopathy(DCM),coronary artery heart disease with segmental wall motion abnormality,and hypertrophic cardiomyopathy(HCM)to determine whether there were differences in the feasibility,accuracy,and repeatability of measuring the LVEDV,LVESV,LV ejection fraction(LVEF)and left atrial end-systolic volume(LAESV)and to compare these measurements with those obtained with traditional twodimensional(2D)and three-dimensional(3D)methods.AIM To evaluate the application value of HM in quantifying left heart chamber volume and LVEF in clinical patients.METHODS A total of 150 subjects who underwent 2D and 3D echocardiography were divided into 4 groups:(1)42 patients with normal heart shape and function(control group,Group A);(2)35 patients with DCM(Group B);(3)41 patients with LV remodeling after acute myocardial infarction(Group C);and(4)32 patients with HCM(Group D).The LVEDV,LVESV,LVEF and LAESV obtained by HM with(HM-RE)and without regional endocardial border editing(HM-NE)were compared with those measured by traditional 2D/3D echocardiographic methods to assess the correlation,consistency,and repeatability of all methods.RESULTS(1)The parameters measured by HM were significantly different among the groups(P<0.05 for all).Compared with Groups A,C,and D,Group B had higher LVEDV and LVESV(P<0.05 for all)and lower LVEF(P<0.05 for all);(2)HM-NE overestimated LVEDV,LVESV,and LAESV with wide biases and underestimated LVEF with a small bias;contour adjustment reduced the biases and limits of agreement(bias:LVEDV,28.17 mL,LVESV,14.92 mL,LAESV,8.18 mL,LVEF,-0.04%).The correlations between HM-RE and advanced cardiac 3D quantification(3DQA)(r_(s)=0.91-0.95,P<0.05 for all)were higher than those between HM-NE(r_(s)=0.85-0.93,P<0.05 for all)and the traditional 2D methods.The correlations between HM-RE and 3DQA were good for Groups A,B,and C but remained weak for Group D(LVEDV and LVESV,r_(s)=0.48-0.54,P<0.05 for all);and(3)The intraobserver and interobserver variability for the HM-RE measurements were low.CONCLUSION HM can be used to quantify the LV volume and LVEF in patients with common heart diseases and sufficient image quality.HM with contour editing is highly reproducible and accurate and may be recommended for clinical practice.展开更多
BACKGROUND Endocardial fibroelastosis(EFE)is a rare heart disease characterized by thickening of the endocardium caused by massive proliferation of collagenous and elastic tissue,usually leading to impaired cardiac fu...BACKGROUND Endocardial fibroelastosis(EFE)is a rare heart disease characterized by thickening of the endocardium caused by massive proliferation of collagenous and elastic tissue,usually leading to impaired cardiac function.Multimodality cardiovascular imaging for the evaluation of EFE with thrombi is even rarer.CASE SUMMARY We report a rare case of EFE associated with multiple cardiovascular thrombi.Three-dimensional(3D)and contrast echocardiography(CE)were used to assess ventricular thrombi.Anticoagulant therapy was administered to eliminate the thrombi.The peripheral contrast-enhanced thrombi with the highest risk were dissolved with anticoagulant therapy at the time of reexamination,which was consistent with the presumption of fresh loose thrombi.CONCLUSION This new echocardiography technique has a great advantage in the diagnosis and treatment of EFE.On the basis of conventional echocardiography,3D echocardiography is used to display the position,shape,and narrow base of the thrombus.CE does not only help to confirm the diagnosis of thrombus,but also determines its risk.展开更多
Stereoscopic three-dimensional echocardiography(S-3DE) is a novel displaying technol-ogy based on real-time 3-dimensional echocardiography (RT-3DE). Our study was to evaluate the feasibility and efficiency of S-3D...Stereoscopic three-dimensional echocardiography(S-3DE) is a novel displaying technol-ogy based on real-time 3-dimensional echocardiography (RT-3DE). Our study was to evaluate the feasibility and efficiency of S-3DE in the diagnosis of atrial septal defect (ASD) and its use in the guidance for transcatheter ASD occlusion. Twelve patients with secundum ASD underwent RT-3DE examination and 9 of the 12 were subjected to transcatheter closure of ASD. Stereoscopic vision was generated with a high-performance volume renderer with red-green stereoscopic glasses. S-3DE was compared with standard RT-3D display for the assessment of the shape, size, and the surrounding tis-sues of ASD and for the guidance of ASD occlusion. The appearance rate of coronary sinus and the mean formation time of the IVC, SVC were compared. Our results showed that S-3DE could measure the diameter of ASD accurately and there was no significant difference in the measurements between S-3DE and standard 3D display (2.89±0.73 cm vs 2.85±0.72 cm, P〉0.05; r=0.96, P〈0.05). The appearance of coronary sinus for S-3DE was higher as compared with the standard 3D display (93.3% vs 100%). The mean time of the IVC, SVC for S-3DE monitor was slightly shorter than that of the standard 3D display (11.0±3.8 s vs 10.3±3.6 s, P〉0.05). The mean completion time of interven-tional procedure was shortened with S-3DE display as compared with standard 3D display (17.3±3.1 min vs 23.0±3.9 min, P〈0.05). Stereoscopic three-dimensional echocardiography could improve the visualization of three-dimensional echocardiography, facilitate the identification of the adjacent structures, decrease the time required for interventional manipulation. It may be a feasible, safe, and efficient tool for guiding transcatheter septal occlusion or the surgical interventions.展开更多
Three-dimensional speckle tracking echocardiography was employed to evaluate the changes of left ventricular systolic strain in 23 heart transplant recipients at 1 st, 3rd, 6th and 12th month after heart transplantati...Three-dimensional speckle tracking echocardiography was employed to evaluate the changes of left ventricular systolic strain in 23 heart transplant recipients at 1 st, 3rd, 6th and 12th month after heart transplantation, and 23 healthy subjects served as controls. The three-dimensional full-volume echocardiographic images of left ventricle were recorded and then were analyzed using EchoPAC software. The strain curves and peak systolic strain values for each segment and overall left ventricular wall were obtained. Left ventricular global peak longitudinal strain (GPSL), global peak radial strain (GPSR), global peak circumferential strain (GPSC) and global peak area strain (GPSA) were measured and then statistically analyzed. There were no significant differences in left ventricular ejection fraction (LVEF) and cardiac output (CO) between heart transplant recipients and controls. The GPSL in heart transplant recipients at 1st month after surgery was significantly lower than that in controls, but close to the normal value at 3rd month after surgery and later. The GPSC, GPSA and GPSR were significantly lower in heart transplant recipients at 1 st, 3rd, 6th and 12th month after surgery than those in controls. It is suggested that three-dimensional speckle tracking echocardiography can be used for monitoring changes of left ventricular systolic strains and evaluating left ventricular systolic function in cardiac allograft.展开更多
Papillary fibroelastomas (PFEs) are benign tumors of the endocardium that most frequently affect cardiac valves and typically present with embolic symptoms such as stroke or transient ischemic attack (TIA). Surgical e...Papillary fibroelastomas (PFEs) are benign tumors of the endocardium that most frequently affect cardiac valves and typically present with embolic symptoms such as stroke or transient ischemic attack (TIA). Surgical excision is usually recommended for left-sided tumors and is associated with excellent long-term outcomes. The use of a robot-assisted, minimally invasive surgical approach for management of mitral valve disease is growing, and has been associated with shorter hospital stays and improved early quality of life. Three-dimensional (3D) transesophageal echocardiography (TEE) offers several advantages in the assessment of mitral valve disease and cardiac tumors, including the ability to precisely locate the site of attachment of the mass and the spatial relationships to surrounding structures. These factors are particularly important when planning a surgical approach. We report two cases of mitral valve PFEs which were successfully removed using a robot-assisted, minimally invasive surgical approach with 3D TEE imaging. This approach to treatment of PFEs is an attractive alternative to the traditional approach involving median sternotomy.展开更多
Background: Real-time three-dimensional echocardiography (RT-3DE) could obtain ventricular volume andejection fraction rapidly and non-invasively without relying on ventricular morphology. This study aims to useRT-3DE...Background: Real-time three-dimensional echocardiography (RT-3DE) could obtain ventricular volume andejection fraction rapidly and non-invasively without relying on ventricular morphology. This study aims to useRT-3DE to evaluate the changes in biventricular volume and systolic function in children with ventricular septaldefect (VSD) and moderate to severe pulmonary hypertension (PH) before surgery. Methods: In this study18 children with VSD and moderate to severe PH (VSD + PH Group) and 18 healthy children of the sameage (Control Group) were recruited. Biventricular volume and systolic function were evaluated by RT-3DE.The measurements included: left and right ventricular volume indexed to body surface area (BSA), stroke volume(SV) indexed to BSA, and ejection fraction (EF). Results: The results showed left and right ventricular volumeindexed to BSA and SV indexed to BSA were significantly increased in VSD + PH Group (VSD + PH Groupvs. Control Group), LVEDV/BSA (ml/m2): 48.67 ± 21.46 vs. 25.59 ± 6.96, RVEDV/BSA (ml/m2): 55.98 ±15.35 vs. 27.69 ± 4.37, LVSV/BSA (ml/m2): 24.08 ± 9.30 vs. 15.14 ± 4.29, RVSV/BSA (ml/m2): 26.02 ± 8.87 vs.14.11 ± 2.89, (P < 0.05). While for EF in VSD + PH Group decreased (VSD + PH Group vs. Control Group),LVEF: 50.93 ± 7.50% vs. 59.38 ± 7.24%, RVEF: 45.84 ± 7.71% vs. 51.05 ± 6.90% (P < 0.05). Conclusion: Inchildren with VSD and moderate to severe PH, increased biventricular volume and decreased systolic functionwere observed with RT-3DE, but biventricular systolic function remained within acceptable limits. The childrenin this study recovered well after surgery without serious perioperative complications, suggesting that biventricularsystolic function may help facilitate the surgical decision-making process in children with VSD and moderate-toseverePH.展开更多
To evaluate the morphology of atrial septum by the live three-dimensional echocardiography (L3DE) and its value of clinical application, L3DE was performed in 62 subjects to observe the morphological characteristics...To evaluate the morphology of atrial septum by the live three-dimensional echocardiography (L3DE) and its value of clinical application, L3DE was performed in 62 subjects to observe the morphological characteristics and dynamic change of the overall anatomic structure of atrial septum. The study examined 49 patients with atrial septal defect (ASD), including 3 patients with atrial septal aneurysm, and 10 healthy subjects. ASD in the 35 patients was surgically confirmed. The maximal diameters of ASD were measured and the percentages of area change were calculated. The parameters derived from L3DE were compared with intraoperative measurements. The results showed that L3DE could directly and clearly display the morphological features of overall anatomic structure of normal atrial septum, repaired and artificially-occluded atrial septum, atrial septal aneurysm. The defect area in ASD patients changed significantly during cardiac cycle, which reached a maximum at end-systole and a minimum at end-diastole, with a mean change percentage of 46.6%, ranging from 14.8% to 73.4%. The sizes obtained from L3DE bore an excellent correlation with intraoperative findings (r=0.90). It is concluded that L3DE can clearly display the overall morphological features and dynamic change of atrial septum and measure the size of ASD area accurately, which is important in the decision to choose therapeutic protocols.展开更多
The application of real-time three-dimensional echocardiography (RT 3DE) in the diagnosis of double orifice mitral valve (DOMV) was explored. Five cases of DOMV were examined by using 2-dimensional echocardiograp...The application of real-time three-dimensional echocardiography (RT 3DE) in the diagnosis of double orifice mitral valve (DOMV) was explored. Five cases of DOMV were examined by using 2-dimensional echocardiography (2DE) and RT 3DE. The spatial morphology of malformed mitral valve and its change in hemodynamics were observed. DOMV associated with partial atrioventricular septal defect was found in 3 cases (in which 2 cases had cleft mitral valve) and isolated DOMV in 2 cases; and moderate to severe mitral regurgitation was detected in 3 cases, and mild mitral regurgitation in 1, and no regurgitation in 1 case; 1 case had complicated rhumatic heart disease. Three cases were preoperatively discovered by 2DE, while 2 missed (1 case was discovered postoperatively). Four cases were diagnosed by RT 3DE preoperatively, and 1 case was diagnosed postoperatively (not examined by RT 3DE preoperatively). It was suggested that RT 3DE is a reliable technique in the diagnosis of DOMV; it permitted comprehensive and noninvasive assessment of mitral valve and may supplement 2D TTE in the assessment of DOMV.展开更多
文摘BACKGROUND Diabetic cardiomyopathy is considered as a chronic complication of diabetes mellitus(DM).Therefore,early detection of left ventricular systolic function(LVSF)damage in DM is essential.AIM To explore the use of the three-dimensional speckle tracking technique(3D-STI)for measuring LVSF in DM patients via meta-analysis.METHODS The electronic databases were retrieved from the initial accessible time to 29 April 2023.The current study involved 9 studies,including 970 subjects.We carried out this meta-analysis to estimate myocardial function in DM compared with controls according to myocardial strain attained by 3D-STI.RESULTS Night articles including 970 subjects were included.No significant difference was detected in the left ventricular ejection fraction between the control and the diabetic group(P>0.05),while differences in global longitudinal strain,global circumferential strain,global radial strain,and global area strain were markedly different between the controls and DM patients(all P<0.05).CONCLUSION The 3D-STI could be applied to accurately measure early LVSF damage in patients with DM.
基金Supported by the Natural Science Foundation of Liaoning ProvinceChina(2013023010)
文摘Objective To evaluate left atrial function in essential hypertension patients with different patterns of left ventricular geometric models by real-time three-dimensional echocardiography (RT-3DE) and left atrial tracking (EAT).
文摘Left ventricular remodeling index (LVRI) was assessed in patients with hypertensive heart disease (HHD) and coronary artery disease (CAD) by real-time three-dimensional echocardiography (RT3DE). RT3DE data of 18 patients with HHD, 20 patients with CAD and 22 normal controis (NC) were acquired. Left ventricular end-diastolic volume (EDV) and left ventricular end-diastolic epicardial volume (EDVepi) were detected by RT3DE and two-dimensional echocardiography Simpson biplane method (2DE). LVRI (left ventricular mass/EDV) was calculated and compared. The results showed that LVRI measurements detected by RT3DE and 2DE showed significant differences inter-groups (P〈0.01). There was no significant difference in NC group (P〉0.05), but significant difference in HHD and CAD intra-group (P〈0.05). There was good positive correlations between LVRI detected by RT3DE and 2DE in NC and HHD groups (t=0.69, P〈0.01; r=0.68, P〈0.01), but no significant correlation in CAD group (r=0.30, P〉0.05). It was concluded that LVRI derived from RT3DE as a new index for evaluating left ventricular remodeling can provide more superiority to LVRI derived from 2DE.
文摘Current guidelines encourage large studies in a diverse population to establish normal reference ranges for three-dimensional(3D)echocardiography for different ethnic groups.This study was designed to establish the normal values of 3D-left ventricular(LV)and left atrial(LA)volume and function in a nationwide,population-based cohort of healthy Han Chinese adults.A total of 1117 healthy volunteers aged 18–89 years were enrolled from 28 collaborating laboratories in China.Two sets of 3D echocardiographic instruments were used,and full-volume echocardiographic images were recorded and transmitted to a core laboratory for image analysis with a vendor-independent off-line workstation.Finally,866 volunteers(mean age of 48.4 years,402 men)were qualified for final analysis.Most parameters exhibited substantial differences between different sex and age groups,even after indexation by body surface area.The normal ranges of 3D-LV and 3D-LA volume and function differed from those recommended by the American Society of Echocardiography and the European Association of Cardiovascular Imaging guidelines,presented by the World Alliance Societies of Echocardiography(WASE)study,and from the 2D values in the EMINCA study.The normal reference values of 3D echocardiography-derived LV and LA volume and function were established for the first time in healthy Han Chinese adults.Normal ranges of 3D-LV and 3D-LA echocardiographic measurements stratified with sex,age,and race should be recommended for clinical applications.
文摘To test the accuracy of real-time three-dimensional echocardiography (RT3DE) imaging system for evaluating left ventricular mass (LVM) in phantom and excised canine heart. Methods Ten left ventricular (LV) wall phantoms made of two rubber-bursas, ten excised canine hearts underwent RT3DE and two-dimensional echocardiography (2DE). In RT3DE "full volume" imaging, the myocardial volume was mea-sured using 2,4,8, and 16-plane method with the analysis software of RT3DE. Mass was then calculated by multiplying the resulting myocardial volume by specific density of myocardial tissue. In 2DE the masses were measured by area-length meth-od. The true LV wall phantom mass was measured by water displacement and the canine LVM was weighed by anatomy, which served as a reference standard. We compared RT3DE or 2DE with true mass. Results In LV wall phantoms, RT3DE correlated with true masses strongly (r = 0.813-0.994) and weakly correlated between 2DE and true masses (r = 0.628). In excised canine hearts, there is an excellent correlation between RT3DE and true masses (r = 0.764-0.991), while 2DE value showed a lesser correlation (r = 0.514). There are no difference between RT-3DE and true masses (P > 0.05) but different between 2DE and true masses (P < 0.05). In different planes, there was no difference between 8-plane and 16-plane (P > 0.05) but different between 8-plane and 2, 4-plane (P < 0.05). Conclusion RT3DE can accurately quantify LVM and provide a new tool to evaluate LV function. For LVM by RT3DE, 8-plane measurement method is the best choice for accuracy and convenience.
文摘AIM To evaluate the long-term outcome of catheter ablation of atrial fibrillation(AF) facilitated by preprocedural threedimensional(3-D) transesophageal echocardiography.METHODS In 50 patients, 3D transesophageal echocardiography(3D TEE) was performed immediately prior to an ablation procedure(paroxysmal AF: 30 patients, persistent AF: 20 patients). The images were available throughout the ablation procedure. Two different ablation strategies were used. In most of the patients with paroxysmal AF, the cryoablation technique was used(Arctic Front Balloon, Cryo Cath Technologies/Medtronic; group A2). In the other patients, a circumferential pulmonary vein ablation was performed using the CARTO system [Biosense Webster; group A1(paroxysmal AF), group B(persistent AF)]. Success rates and complication rates were analysed at 4-year follow-up.RESULTS A 3D TEE could be performed successfully in all patients prior to the ablation procedure and all four pulmonaryvein ostia could be evaluated in 84% of patients. The image quality was excellent in the majority of patients and several variations of the pulmonary vein anatomy could be visualized precisely(e.g., common pulmonary vein ostia, accessory pulmonary veins, varying diameter of the left atrial appendage and its distance to the left superior pulmonary vein). All ablation procedures could be performed as planned and almost all pulmonary veins could be isolated successfully. At 48-mo followup, 68.0% of all patients were free from an arrhythmia recurrence(group A1: 72.7%, group A2: 73.7%, group B: 60.0%). There were no major complications.CONCLUSION3 D TEE provides an excellent overview over the left atrial anatomy prior to AF ablation procedures and these procedures are associated with a favourable long-term outcome.
文摘The optimal plane for measurement of the right ventricular (RV) volumes by real-time three-dimensional echocardiography (RT3DE) was determined and the feasibility and accuracy of RT3DE in studying RV systolic function was assessed. RV “Full volume” images were acquired by RT3DE in 22 healthy subjects. RV end-diastolic volumes (RVEDV) and end-systolic volumes (RVESV) were outlined using apical biplane, 4-plane, 8-plane, 16-plane offline separately. RVSV and RVEF were calculated. Meanwhile tricuspid annual systolic excursion (TASE) was measured by M-mode echo. LVSV was outlined by 2-D echo according to the biplane Simpson's rule. The results showed: (1) There was a good correlation between RVSV measured from series planes and LVSV from 2-D echo (r=0.73; r=0.69; r=0.63; r=0.66, P<0.25—0.0025); (2) There were significant differences between RVEDV in biplane and those in 4-, 8-, 16-plane (P<0.001). There was also difference between RV volume in 4-plane and that in 8-plane (P<0.05), but there was no significant difference between RV volume in 8-plane and that in 16-plane (P>0.05); (3) Inter-observers and intro-observers variability analysis showed that there were close agreements and relations for RV volumes (r=0.986, P<0.001; r=0.93, P<0.001); (4) There was a significantly positive correlation of TASE to RVSV and RVEF from RT3DE (r=0.83; r=0.90). So RV volume measures with RT3DE are rapid, accurate and reproducible. In view of RV's complex shape, apical 8-plane method is better in clinical use. It may allow early detection of RV systolic function.
基金Supported by Medical and Health Foundation Project of Zhejiang Province,China,No.2020KY690Natural Science Foundation of Zhejiang Province,China,No.LGF20H020004.
文摘BACKGROUND The anthracycline chemotherapeutic drugs are cardiotoxic.Studies have found some indicators related to cardiotoxicity.However,there is currently no accurate indicator that can predict cardiac toxicity early.AIM To explore the diagnostic value of real-time three-dimensional echocardiography(RT3DE)in predicting cardiac toxicity in breast cancer patients undergoing chemotherapy.METHODS Female breast cancer patients who underwent radical mastectomy and postoperative chemotherapy at the Affiliated Hanzhou First People’s Hospital,Zhejiang University School of Medicine were recruited.All patients were routinely administered with chemotherapy for four cycles(T1-T4)after surgery.Two-dimensional(2D)echocardiography,RT3DE,and serological examinations were performed after each cycle of chemotherapy.Patients were divided into a toxic group and a non-toxic group based on whether patients hadΔleft ventricular ejection fraction>10%after one year of chemotherapy.Repeated measurement analysis of variance was used to compare the changes in 2D echocardiographic indicators,serological indicators,and RT3DE indicators before independent predictive indicators for cardiac toxicity in postoperative chemotherapy patients.Receiver operating characteristics(ROC)curve analysis was performed to analyze the diagnostic value of potential indicators in the diagnosis of cardiotoxicity.RESULTS A total of 107 female breast cancer patients were included in the study.T4 maximum peak velocity in early diastole(E peak)/mitral annulus lateral tissue Doppler(e'peak)(E/e'),serological indicators[T4 cardiac troponin I(cTnI)and T4 pro-brain natriuretic peptide(Pro-BNP)],T3 minimum left atrial volume(LAV),T4 LAVmin,T3 LAV before the start of the P wave(LAVprep),and T4 LAVprep in the toxicity group were significantly higher than those in the nontoxic group.Multivariate logistic regression found that T4 cTnI,T4 Pro-BNP,T3 LAVmin,T4 LAVmin,T3 LAVprep,and T4 LAVprep had potential predictive value for cardiac toxicity(P<0.05).ROC results showed that T4 LAVmin had the highest accuracy for diagnosing cardiac toxicity[area under the curve(AUC)=0.947;sensitivity=78.57%;specificity=94.62%],followed by T4 LAVprep(AUC=0.899;sensitivity=100%;specificity=66.67%).The accuracies of LAVprep and LAVprep in predicting cardiac toxicity were higher than those of T3 LAVmin and T3 LAVprep.CONCLUSION RT3DE of left atrial volume can be used to predict the cardiotoxicity caused by chemotherapy,and it is expected to guide the clinical adjustment of dose and schedule in time.
文摘Objective To evaluate the feasibility and accuracy of measurement of myocardial perfusion defects with intravenous contrast-enhanced real-time three-dimensional echocardiography (CE-RT3DE). Methods RT3DE was performed in 21 open-chest mongrel dogs undergoing acute ligation of the left anterior descending artery (LAD, n=14) or distal branch of the left circumflex artery (LCX, n=7). A perfluorocarbon microbubble contrast agent was injected intravenously to assess the resulting myocardial perfusion defects with Philips Sonos-7500 ultrasound system. Evans blue dye was injected into the occluded coronary artery for subsequent anatomic identification of underperfused myocardium. In vitro anatomic measurement of myocardial mass after removal of the animal’s heart was regarded as the control. Blinded off-line calculation of left ventricular mass and perfusion defect mass from RT3DE images were performed using an interactive aided-manual tracing technique.Results Total left ventricular (LV) myocardial mass ranged from 38.9 to 78.5 (mean±SD: 60.0±10.1) g. The mass of perfusion defect ranged from 0 to 21.4 (mean±SD: 12.0±5.0) g or 0 to 27% of total LV mass (mean±SD: 19%±6%). The RT3DE estimation of total LV mass (mean±SD: 59.8±9.9 g) strongly correlated with the anatomic measurement (r=0.98; y=2.01+0.96x). The CE-RT3DE calculation of the mass of underperfused myocardium (mean±SD: 12.3±5.3 g) also strongly correlated with the anatomic measurement (r=0.96; y=-0.10+1.04x) and when expressed as percentage of total LV mass (r=0.95; y=-0.20+1.04x). Conclusions RT3DE with myocardial contrast opacification could accurately estimate underperfused myocardial mass in dogs of acute coronary occlusion and would play an important role in quantitative assessment of myocardial perfusion defects in patients with coronary artery disease.
基金supported by a grant from the Youth Science Foundation of China (No.30600213)
文摘The present study evaluated the application of three dimensional echocardigraphy (3DE) in the diagnosis of atrial septal defect (ASD) and the measurement of its size by 3DE and compared the size with surgical findings. Two-dimensional and real-time three dimensional echocardiography (RT3DE) was performed in 26 patients with atrial septal defect, and the echocardiographic data were compared with the surgical findings. Significant correlation was found between defect diameter by RT3DE and that measured during surgery (r=0.77, P〈0.001). The defect area changed significantly during cardiac cycle. Percentage change in defect size during cardiac cycle ranged from 6%-70%. Our study showed that the size and morphology of atrial septal defect obtained with RT3DE correlate well with surgical findings. Therefore, RT3DE is a feasible and accurate non-invasive imaging tool for assessment of atrial septal size and dynamic changes.
基金supported by grants from the Science and Technology Department of the Hubei Province Foundation(No.2019CFC895)2016 Wuhan Young and Middle-Aged Talent Plan Foundation.
文摘Objective:To establish a quantitative evaluation of the left ventricle's systolic function in patients with chronic kidney failure(CKF)by three-dimensional speckle-tracking echocardiography.Methods:Two-dimensional and three-dimensional transthoracic echocardiography was performed on 30 patients with CKF.The ejection fraction,mass and global peak longitudinal strain,global circumferential strain,global area strain,and global radial strain of the left ventricle were calculated.Results:The ejection fraction,mass and global peak longitudinal strain(GLS),global circumferential strain(GCS),global area strain(GAS),and global radial strain(GRS)in the CKF group were significantly lower than those in the control group.Simultaneously,the GLS,GCS,GAS and GRS were well correlated with the ejection fraction.For patients with normal ejection fraction in the CKF group,the GLS,GCS,GAS and GRS were lower than those in the control group,while the left ventricular mass was significantly higher in CKF patients than in the control group.For patients with hypertension in the CKF group,ejection fraction,GLS,GCS,GAS and GRS calculated using three-dimensional echocardiography were significantly lower than those in patients with normal blood pressure;however,the myocardial mass was higher.Conclusions:The parameters(GLS,GCS,GAS and GRS)calculated using three-dimensional speckle-tracking software were lower in the CKF group.Simultaneously,the left ventricular mass was higher in CFK patients than in the control group,thus showing that the myocardial contraction function was impaired and that myocardial remodeling had occurred.
文摘BACKGROUND HeartModel(HM)is a fully automated adaptive quantification software that can quickly quantify left heart volume and left ventricular function.This study used HM to quantify the left ventricular end-diastolic(LVEDV)and end-systolic volumes(LVESV)of patients with dilated cardiomyopathy(DCM),coronary artery heart disease with segmental wall motion abnormality,and hypertrophic cardiomyopathy(HCM)to determine whether there were differences in the feasibility,accuracy,and repeatability of measuring the LVEDV,LVESV,LV ejection fraction(LVEF)and left atrial end-systolic volume(LAESV)and to compare these measurements with those obtained with traditional twodimensional(2D)and three-dimensional(3D)methods.AIM To evaluate the application value of HM in quantifying left heart chamber volume and LVEF in clinical patients.METHODS A total of 150 subjects who underwent 2D and 3D echocardiography were divided into 4 groups:(1)42 patients with normal heart shape and function(control group,Group A);(2)35 patients with DCM(Group B);(3)41 patients with LV remodeling after acute myocardial infarction(Group C);and(4)32 patients with HCM(Group D).The LVEDV,LVESV,LVEF and LAESV obtained by HM with(HM-RE)and without regional endocardial border editing(HM-NE)were compared with those measured by traditional 2D/3D echocardiographic methods to assess the correlation,consistency,and repeatability of all methods.RESULTS(1)The parameters measured by HM were significantly different among the groups(P<0.05 for all).Compared with Groups A,C,and D,Group B had higher LVEDV and LVESV(P<0.05 for all)and lower LVEF(P<0.05 for all);(2)HM-NE overestimated LVEDV,LVESV,and LAESV with wide biases and underestimated LVEF with a small bias;contour adjustment reduced the biases and limits of agreement(bias:LVEDV,28.17 mL,LVESV,14.92 mL,LAESV,8.18 mL,LVEF,-0.04%).The correlations between HM-RE and advanced cardiac 3D quantification(3DQA)(r_(s)=0.91-0.95,P<0.05 for all)were higher than those between HM-NE(r_(s)=0.85-0.93,P<0.05 for all)and the traditional 2D methods.The correlations between HM-RE and 3DQA were good for Groups A,B,and C but remained weak for Group D(LVEDV and LVESV,r_(s)=0.48-0.54,P<0.05 for all);and(3)The intraobserver and interobserver variability for the HM-RE measurements were low.CONCLUSION HM can be used to quantify the LV volume and LVEF in patients with common heart diseases and sufficient image quality.HM with contour editing is highly reproducible and accurate and may be recommended for clinical practice.
基金Supported by National Natural Science Foundation of China,No.81571686.
文摘BACKGROUND Endocardial fibroelastosis(EFE)is a rare heart disease characterized by thickening of the endocardium caused by massive proliferation of collagenous and elastic tissue,usually leading to impaired cardiac function.Multimodality cardiovascular imaging for the evaluation of EFE with thrombi is even rarer.CASE SUMMARY We report a rare case of EFE associated with multiple cardiovascular thrombi.Three-dimensional(3D)and contrast echocardiography(CE)were used to assess ventricular thrombi.Anticoagulant therapy was administered to eliminate the thrombi.The peripheral contrast-enhanced thrombi with the highest risk were dissolved with anticoagulant therapy at the time of reexamination,which was consistent with the presumption of fresh loose thrombi.CONCLUSION This new echocardiography technique has a great advantage in the diagnosis and treatment of EFE.On the basis of conventional echocardiography,3D echocardiography is used to display the position,shape,and narrow base of the thrombus.CE does not only help to confirm the diagnosis of thrombus,but also determines its risk.
文摘Stereoscopic three-dimensional echocardiography(S-3DE) is a novel displaying technol-ogy based on real-time 3-dimensional echocardiography (RT-3DE). Our study was to evaluate the feasibility and efficiency of S-3DE in the diagnosis of atrial septal defect (ASD) and its use in the guidance for transcatheter ASD occlusion. Twelve patients with secundum ASD underwent RT-3DE examination and 9 of the 12 were subjected to transcatheter closure of ASD. Stereoscopic vision was generated with a high-performance volume renderer with red-green stereoscopic glasses. S-3DE was compared with standard RT-3D display for the assessment of the shape, size, and the surrounding tis-sues of ASD and for the guidance of ASD occlusion. The appearance rate of coronary sinus and the mean formation time of the IVC, SVC were compared. Our results showed that S-3DE could measure the diameter of ASD accurately and there was no significant difference in the measurements between S-3DE and standard 3D display (2.89±0.73 cm vs 2.85±0.72 cm, P〉0.05; r=0.96, P〈0.05). The appearance of coronary sinus for S-3DE was higher as compared with the standard 3D display (93.3% vs 100%). The mean time of the IVC, SVC for S-3DE monitor was slightly shorter than that of the standard 3D display (11.0±3.8 s vs 10.3±3.6 s, P〉0.05). The mean completion time of interven-tional procedure was shortened with S-3DE display as compared with standard 3D display (17.3±3.1 min vs 23.0±3.9 min, P〈0.05). Stereoscopic three-dimensional echocardiography could improve the visualization of three-dimensional echocardiography, facilitate the identification of the adjacent structures, decrease the time required for interventional manipulation. It may be a feasible, safe, and efficient tool for guiding transcatheter septal occlusion or the surgical interventions.
基金supported by Innovation Research Fund of Huazhong University of Science and Technology,China(No.2012QN183)
文摘Three-dimensional speckle tracking echocardiography was employed to evaluate the changes of left ventricular systolic strain in 23 heart transplant recipients at 1 st, 3rd, 6th and 12th month after heart transplantation, and 23 healthy subjects served as controls. The three-dimensional full-volume echocardiographic images of left ventricle were recorded and then were analyzed using EchoPAC software. The strain curves and peak systolic strain values for each segment and overall left ventricular wall were obtained. Left ventricular global peak longitudinal strain (GPSL), global peak radial strain (GPSR), global peak circumferential strain (GPSC) and global peak area strain (GPSA) were measured and then statistically analyzed. There were no significant differences in left ventricular ejection fraction (LVEF) and cardiac output (CO) between heart transplant recipients and controls. The GPSL in heart transplant recipients at 1st month after surgery was significantly lower than that in controls, but close to the normal value at 3rd month after surgery and later. The GPSC, GPSA and GPSR were significantly lower in heart transplant recipients at 1 st, 3rd, 6th and 12th month after surgery than those in controls. It is suggested that three-dimensional speckle tracking echocardiography can be used for monitoring changes of left ventricular systolic strains and evaluating left ventricular systolic function in cardiac allograft.
文摘Papillary fibroelastomas (PFEs) are benign tumors of the endocardium that most frequently affect cardiac valves and typically present with embolic symptoms such as stroke or transient ischemic attack (TIA). Surgical excision is usually recommended for left-sided tumors and is associated with excellent long-term outcomes. The use of a robot-assisted, minimally invasive surgical approach for management of mitral valve disease is growing, and has been associated with shorter hospital stays and improved early quality of life. Three-dimensional (3D) transesophageal echocardiography (TEE) offers several advantages in the assessment of mitral valve disease and cardiac tumors, including the ability to precisely locate the site of attachment of the mass and the spatial relationships to surrounding structures. These factors are particularly important when planning a surgical approach. We report two cases of mitral valve PFEs which were successfully removed using a robot-assisted, minimally invasive surgical approach with 3D TEE imaging. This approach to treatment of PFEs is an attractive alternative to the traditional approach involving median sternotomy.
基金Wuhan Health and Family Planning Commission Grant/Award(WX16D18).
文摘Background: Real-time three-dimensional echocardiography (RT-3DE) could obtain ventricular volume andejection fraction rapidly and non-invasively without relying on ventricular morphology. This study aims to useRT-3DE to evaluate the changes in biventricular volume and systolic function in children with ventricular septaldefect (VSD) and moderate to severe pulmonary hypertension (PH) before surgery. Methods: In this study18 children with VSD and moderate to severe PH (VSD + PH Group) and 18 healthy children of the sameage (Control Group) were recruited. Biventricular volume and systolic function were evaluated by RT-3DE.The measurements included: left and right ventricular volume indexed to body surface area (BSA), stroke volume(SV) indexed to BSA, and ejection fraction (EF). Results: The results showed left and right ventricular volumeindexed to BSA and SV indexed to BSA were significantly increased in VSD + PH Group (VSD + PH Groupvs. Control Group), LVEDV/BSA (ml/m2): 48.67 ± 21.46 vs. 25.59 ± 6.96, RVEDV/BSA (ml/m2): 55.98 ±15.35 vs. 27.69 ± 4.37, LVSV/BSA (ml/m2): 24.08 ± 9.30 vs. 15.14 ± 4.29, RVSV/BSA (ml/m2): 26.02 ± 8.87 vs.14.11 ± 2.89, (P < 0.05). While for EF in VSD + PH Group decreased (VSD + PH Group vs. Control Group),LVEF: 50.93 ± 7.50% vs. 59.38 ± 7.24%, RVEF: 45.84 ± 7.71% vs. 51.05 ± 6.90% (P < 0.05). Conclusion: Inchildren with VSD and moderate to severe PH, increased biventricular volume and decreased systolic functionwere observed with RT-3DE, but biventricular systolic function remained within acceptable limits. The childrenin this study recovered well after surgery without serious perioperative complications, suggesting that biventricularsystolic function may help facilitate the surgical decision-making process in children with VSD and moderate-toseverePH.
文摘To evaluate the morphology of atrial septum by the live three-dimensional echocardiography (L3DE) and its value of clinical application, L3DE was performed in 62 subjects to observe the morphological characteristics and dynamic change of the overall anatomic structure of atrial septum. The study examined 49 patients with atrial septal defect (ASD), including 3 patients with atrial septal aneurysm, and 10 healthy subjects. ASD in the 35 patients was surgically confirmed. The maximal diameters of ASD were measured and the percentages of area change were calculated. The parameters derived from L3DE were compared with intraoperative measurements. The results showed that L3DE could directly and clearly display the morphological features of overall anatomic structure of normal atrial septum, repaired and artificially-occluded atrial septum, atrial septal aneurysm. The defect area in ASD patients changed significantly during cardiac cycle, which reached a maximum at end-systole and a minimum at end-diastole, with a mean change percentage of 46.6%, ranging from 14.8% to 73.4%. The sizes obtained from L3DE bore an excellent correlation with intraoperative findings (r=0.90). It is concluded that L3DE can clearly display the overall morphological features and dynamic change of atrial septum and measure the size of ASD area accurately, which is important in the decision to choose therapeutic protocols.
文摘The application of real-time three-dimensional echocardiography (RT 3DE) in the diagnosis of double orifice mitral valve (DOMV) was explored. Five cases of DOMV were examined by using 2-dimensional echocardiography (2DE) and RT 3DE. The spatial morphology of malformed mitral valve and its change in hemodynamics were observed. DOMV associated with partial atrioventricular septal defect was found in 3 cases (in which 2 cases had cleft mitral valve) and isolated DOMV in 2 cases; and moderate to severe mitral regurgitation was detected in 3 cases, and mild mitral regurgitation in 1, and no regurgitation in 1 case; 1 case had complicated rhumatic heart disease. Three cases were preoperatively discovered by 2DE, while 2 missed (1 case was discovered postoperatively). Four cases were diagnosed by RT 3DE preoperatively, and 1 case was diagnosed postoperatively (not examined by RT 3DE preoperatively). It was suggested that RT 3DE is a reliable technique in the diagnosis of DOMV; it permitted comprehensive and noninvasive assessment of mitral valve and may supplement 2D TTE in the assessment of DOMV.