Application of a novel computer-assisted surgery system in percutaneous nephrolithotomy:A controlled study 被引量:1
1
作者 Fei Qin Ye-Feng Sun +8 位作者 Xin-Ning Wang Bin Li Zhi-Lei Zhang Ming-Xin Zhang Fei Xie Shuai-Hong Liu Zi-Jie Wang Yuan-Chao Cao Wei Jiao 《World Journal of Clinical Cases》 SCIE 2022年第18期6039-6049,共11页
BACKGROUND Most complex renal stones are managed primarily with percutaneous nephrolithotomy(PCNL).However,PCNL is still a great challenge for surgeons because of poor comprehension on complex adjacent structures.Nove... BACKGROUND Most complex renal stones are managed primarily with percutaneous nephrolithotomy(PCNL).However,PCNL is still a great challenge for surgeons because of poor comprehension on complex adjacent structures.Novel techniques are required to assist in planning and navigation.AIM To apply and evaluate the Hisense computer-assisted surgery(CAS)system in PCNL.METHODS A total of 60 patients with complex renal stones were included.Thirty patients in the CAS group had three-dimensional(3 D)virtual models constructed with the CAS system.The model assisted in planning and navigating in the CAS system.Thirty patients in the control group planned and navigated as standard PCNL,without the application of the CAS system.Success rate of one attempt,operation time,initial stone-free rate,decrease in hemoglobin,and complications were collected and analyzed.RESULTS There were no statistically significant differences in the baseline characteristics or planning characteristics.The success rate of one puncturing attempt(90%vs 67%,P=0.028)and the initial stone-free rate(87%vs 63%,P=0.037)were significantly higher in the CAS group.However,there were no statistically significant differences in the operation time(89.20±29.60 min vs 92.33±33.08 min,P=0.859)or in the decrease in hemoglobin(11.07±8.32 g/L vs 9.03±11.72 g/L,P=0.300)between the CAS group and the control group.No statistically significant differences in the incidence of complications(Clavien-Dindo grade≥2)were found.CONCLUSION Compared with standard PCNL,CAS-assisted PCNL had advantages in terms of the puncturing success rate and stone-free rate.The Hisense CAS System was recommended to assist in preoperative planning and intraoperative navigation for an intuitive,precise and convenient PCNL. 展开更多
关键词 computer-assisted surgery system Percutaneous nephrolithotomy three-dimensional reconstruction planning NAVIGATION
下载PDF
Predicting Delivery Error Using a DICOM-RT Plan for Volumetric Modulated Arc Therapy
2
作者 Hideharu Miura Masao Tanooka +6 位作者 Masayuki Fujiwara Yasuhiro Takada Hiroshi Doi Soichi Odawara Kengo Kosaka Norihiko Kamikonya Shozo Hirota 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2014年第2期82-87,共6页
The purpose of this study was to investigate the prediction of mechanical error using DICOM-RT plan parameters for volumetric modulated arc therapy (VMAT). We created plans for gantry rotation arcs of 360° and 18... The purpose of this study was to investigate the prediction of mechanical error using DICOM-RT plan parameters for volumetric modulated arc therapy (VMAT). We created plans for gantry rotation arcs of 360° and 180° (full-arc and half-arc VMAT) for six maxillary sinus cancer cases using a Monaco treatment planning system, and delivered the doses with a linear accelerator. We calculated DICOM-RT plan parameters, including gantry, multileaf collimator (MLC) positions and Monitor Units (MU). We compared plans with regard to gantry angle per MU (degrees/MU) and MLC travel per MU (mm/MU) for each segment. Calculated gantry angle/MLC position speeds and errors were evaluated by comparison with the log file. On average, the half-arc VMAT plan resulted in 47% and 35% fewer degrees/MU and mm/MU than the full-arc VMAT plan, respectively. The root mean square (r.m.s.) gantry and MLC speeds showed a linear relationship with calculated degrees/MU and mm/MU, with coefficients of determination (R2) of 0.86 and 0.72, respectively. The r.m.s. gantry angle and MLC position errors showed a linear relationship with calculated degrees/MU and mm/MU with R2 of 0.63 and 0.76, respectively. Deviations from plan parameters were related to mechanical error for VMAT, and provided quantitative information without the need for VMAT delivery. These parameters can be used in the selection of treatment planning. 展开更多
关键词 Volumetric-Modulated Arc Therapy DICOM-RT plan PATIENT-SPECIFIC QA radiotherapy planning computer-assisted
下载PDF
Comparison of Dosiology between Three Dimensional Conformal and Intensity-modulated Radiotherapies (5 and 7 fields) in Gastric Cancer Post-surgery 被引量:1
3
作者 马虹 韩军 +1 位作者 张涛 柯杨 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2013年第5期759-764,共6页
The purpose of this study was to compare the dose distribution of intensity-modulated ra- diotherapy (IMRT) in 7 and 5 fields as well as 3-D conformal radiotherapy (3D-CRT) plans for gastric cancer using dosimetri... The purpose of this study was to compare the dose distribution of intensity-modulated ra- diotherapy (IMRT) in 7 and 5 fields as well as 3-D conformal radiotherapy (3D-CRT) plans for gastric cancer using dosimetric analysis. In 15 patients with gastric cancer after D1 resection, dosimetric pa- rameters for IMRT (7 and 5 fields) and 3D-CRT were calculated with a total dose of 45 Gy (1.8 Gy/day) These parameters included the conformal index (CI), homogeneity index (HI), maximum dose spot for the planned target volume (PTV), dose-volume histogram (DVH) and dose distribution in the organs at risk (OAR), mean dose (Dmean), maximal dose (Dmax) in the spinal cord, percentage of the normal liver volume receiving more than 30 Gy (V30) and percentage of the normal kidney volume receiving more than 20 Gy (V20). IMRT (7 and 5 fields) and 3D-CRT achieved the PTV coverage. However, IMRT presented significantly higher CI and HI values and lower maximum dose spot distribution than 3D-CRT (P=0.001). For dose distribution of OAR, IMRT had a significantly lower Dmean and Dmax in spinal cord than 3D-CRT (P=-0.009). There was no obvious difference in V30 of liver and V20 of kidney between IMRT and 3D-CRT, but 5-field IMRT showed lower Dmean in the normal liver than other two plans (P=0.001). IMRT revealed favorable tumor coverage as compared to 3D-CRT and IMRT plans. Specifically, 5-field IMRT plan was superior to 3D-CRT in protecting the spinal cord and liver, but this superiority was not observed in the kidney. Further studies are needed to compare differences among the three approaches. 展开更多
关键词 gastric cancer radiation therapy three-dimensional treatment planning system inten-sity-modulated radiotherapy DOSIMETRY