BACKGROUND Numerous variables are linked to the success of vaginal delivery,including the subpubic arch angle(SPAA)during labor,the importance of which has not yet been fully elucidated.AIM To examine the SPAA distrib...BACKGROUND Numerous variables are linked to the success of vaginal delivery,including the subpubic arch angle(SPAA)during labor,the importance of which has not yet been fully elucidated.AIM To examine the SPAA distributional characteristics and to ascertain SPAA’s ability to predict the type and duration of labor.METHODS We determined the SPAA and analyzed the corresponding data.We also evaluated the relationship between the SPAA and the mode of delivery and the duration of labor by regression.The present study comprised a total of 301 pregnant women who had given birth at Beijing Tiantan Hospital of the Capital Medical University between January and December of 2021.RESULTS Our analysis of 301 pregnant women revealed that the SPAA measured using three-dimensional trans-perineal ultrasound had a minimum angle of 81°and a maximum angle of 122.2°.The angle in the normal vaginal delivery group was greater than that in the labor cesarean group(P=0.000).The SPAA was a highly significant positive predictor of normal vaginal delivery(P=0.000)with an area under the curve of 0.782(P=0.000;95%CI:0.717-0.848).We found the length of the second stage of labor to be positively influenced by the SPAA using linear regression analysis(P=0.045).CONCLUSION The SPAA was a highly significant positive predictor of normal vaginal delivery.The length of the second stage of labor and normal vaginal birth were predicted by SPAA.展开更多
AIM To assess the role of three-dimensional endoanal ultrasound (3D-EAUS) for morphological assessment of the anal sphincter of female patients with chronic proctalgia (CP). METHODS In this unmatched case control stud...AIM To assess the role of three-dimensional endoanal ultrasound (3D-EAUS) for morphological assessment of the anal sphincter of female patients with chronic proctalgia (CP). METHODS In this unmatched case control study, 30 consecutive female patients with CP and 25 normal women (control group) were enrolled. 3D-EAUS was performed in all subjects. Thickness and length of internal anal sphincter (IAS), thickness of puborectalis muscle (PR), length of the external anal sphincter (EAS) plus PR, and puborectalis angle were measured and compared between the two groups. RESULTS Patients with CP had significantly shorter IAS length and greater PR thickness, as compared to those in normal individuals (26.28 +/- 3.59 mm vs 28.87 +/- 4.84 mm, P < 0.05 and 9.67 +/- 1.57 mm vs 8.85 +/- 0.97 mm, P < 0.05, respectively). No significant between-group differences were observed with respect to IAS thickness and the EAS plus PR length (P > 0.05). Puborectalis angle in the CP group was significantly decreased, both in resting (88.23 degrees +/- 1.81 degrees vs 89.94 degrees +/- 2.07 degrees in control group, P < 0.05) and straining (88.47 degrees +/- 3.32 degrees vs 90.72 degrees +/- 1.87 degrees in control group, P < 0.05) phases, which suggest the presence of paradoxical contraction of PR in patients with CP. In the CP group, no significant difference in puborectalis angle was observed between the resting and straining phases (88.23 degrees +/- 1.81 degrees vs 88.47 degrees +/- 3.32 degrees respectively, P > 0.05). CONCLUSION The association of greater PR thickness and paradoxical contraction of PR with CP suggest their potential value as markers of CP.展开更多
This study assessed the clinical application of transvaginal three-dimensional ultrasound (3D TVUS) in the diagnosis of congenital uterine malformation. A retrospective study was performed on 62 patients with congen...This study assessed the clinical application of transvaginal three-dimensional ultrasound (3D TVUS) in the diagnosis of congenital uterine malformation. A retrospective study was performed on 62 patients with congenital uterine malformation confirmed hysteroscopically and/or laparoscopically. The patients were subjected to transvaginal two-dimensional ultrasound (2D TVUS) and 3D TVUS. The accuracy rate was compared between the two methods. The accuracy rate of 3D TVUS was (98.38%, 61/62), higher than that of 2D TVUS (80.65%, 50/62). 3D TVUS coronal plane imaging could demon- strate the internal shape of the endometrial cavity and the external contour of the uterine fundus. It al- lowed accurate measurement on the coronary plane, and could three-dimensionally show the image of cervical tube, thereby providing information for the diagnosis of some complex uterine malformation. 3D TVUS imaging can obtain comprehensive information of the uterus malformation, and it is superior to 2D TVUS for the diagnosis of congenital uterine malformations, especially complex uterine anomaly.展开更多
The purpose of this study was to evaluate the outcome of patients with unresectable hepatocellular carcinoma(HCC) treated by sequential therapy of transcatheter arterial chemoembolization(TACE),three-dimensional c...The purpose of this study was to evaluate the outcome of patients with unresectable hepatocellular carcinoma(HCC) treated by sequential therapy of transcatheter arterial chemoembolization(TACE),three-dimensional conformal radiotherapy(3-DCRT) and high-intensity focused ultrasound(HIFU).From October,2005 to September,2010,120 patients with unresectable HCC received the sequential treatments of several courses of TACE followed in 2-4 weeks by 3-DCRT and then a single session of HIFU with a curative intent.The median tumor irradiation dose was 40 Gy.Tumor response,toxicity and overall survival rate were analyzed.Clinicopathologic factors affecting the primary technique effectiveness and overall survival rates were investigated by univariate analysis or multivariate analysis.All 120 HCC patients were followed up by the last follow-up time.Among these patients,hepatic toxicities due to treatment were notable in 9 cases.Gastrointestinal bleeding after the overall treatment occurred in 2 cases,leukopenia of grade III was detected in 1 case,radiation-induced liver disease(RILD) was observed in 2 patients,and first-and second-degree skin burn around the HIFU treatment zone were observed in 2 patients and 1 patient,respectively.Among 120 patients,23,83 and 14 cases achieved partial response,stable disease and progressive disease,respectively.The overall survival rates at 1 year,3 years and 5 years were 70%,35% and 15%,respectively,with a median survival time of 26 months.Both Child-Pugh liver function grading and radiation dose were determined to be independent predictors for overall survival revealed by the multivariate analysis.It is concluded that the sequential therapy of TACE,3-DCRT and HIFU is a promising therapeutic regimen for unresectable HCC.展开更多
BACKGROUND: It is not possible to reconstruct the inner structure of the spinal cord, such as gray matter and spinal tracts, from the Visual Human Project database or CT and MRI databases, due to low image resolution...BACKGROUND: It is not possible to reconstruct the inner structure of the spinal cord, such as gray matter and spinal tracts, from the Visual Human Project database or CT and MRI databases, due to low image resolution and contrast in macrosection images. OBJECTIVE: To explore a semi-automatic computerized three-dimensional (3D) reconstruction of human spinal cord based on histological serial sections, in order to solve issues such as low contrast. DESIGN, TIME AND SETTING: An experimental study combining serial section techniques and 3D reconstruction, performed in the laboratory of Human Anatomy and Histoembryology at the Medical School of Nantong University during January to April 2008. SETTING: Department of Anatomy, Institute of Neurobiology, Jiangsu Province Key Laboratory of Neural Regeneration, Laboratory of Image Engineering. MATERIALS: A human lumbar spinal cord segment from fresh autopsy material of an adult male. METHODS: After 4% paraformaldehyde fixation for three days, serial sections of the lumbar spinal cord were cut on a Leica cryostat and mounted on slides in sequence, with eight sections aligned separately on each slide. All sections were stained with Luxol Fast Blue to reveal myelin sheaths. After gradient dehydration and clearing, the stained slides were coverslipped. Sections were observed and images recorded under a light microscope using a digital camera. Six images were acquired at x25 magnification and automatically stitched into a complete section image. After all serial images were obtained, 96 complete serial images of the human lumbar cord segment were automatically processed with "Curves", "Autocontrast", "Gray scale 8 bit", "Invert", "Image resize to 50%" steps using Photoshop 7.0 software. All images were added in order into 3D-DOCTOR 4.0 software as a stack, where serial images were automatically realigned with neighboring images and semi-automatically segmented for white matter and gray matter. Finally, simple surface and volume reconstruction were completed on a personal computer. The reconstructed human lumbar spinal cord segment was interactively observed, cut, and measured. MAIN OUTCOME MEASURES: The reconstructed human lumbar spinal cord segment. RESULTS: Compared with serial images obtained from other image modalities, such as CT, MRI, and macrosections from The Visual Human Project database, the Luxol Fast Blue stained histological serial section images exhibited higher resolution and contrast between gray and white matter. Image processing and 3D reconstruction steps were semi-automatically performed with related software. The 3D reconstructed human lumbar cord segment were observed, cut, and measured on a PC. CONCLUSION: A semi-automatically computerized method, based on histological serial sections, is an effective way to 3D-reconstruct the human spinal cord.展开更多
Summary: This study sought to evaluate the contribution of two-dimensional ultrasound (2D-US) and three-dimensional skeletal imaging ultrasound (3D-SUIS) in the prenatal diagnosis of sirenomelia. Be- tween Septem...Summary: This study sought to evaluate the contribution of two-dimensional ultrasound (2D-US) and three-dimensional skeletal imaging ultrasound (3D-SUIS) in the prenatal diagnosis of sirenomelia. Be- tween September 2010 and April 2014, a prospective study was conducted in a single referral center using 3D-SU1S performed after 2D-US in 10 cases of sirenomelia. Diagnostic accuracy and detailed findings were compared with postnatal three-dimensional helical computed tomography (3D-HCT), radiological findings and autopsy. Pregnancy was terminated in all 10 sirenomelia cases, including 9 singletons and I conjoined twin pregnancy, for a total of 5 males and 5 females. These cases of sirenomelia were deter- mined by autopsy and/or chromosomal examination. Initial 2D-US showed that there were 10 cases of oligohydranmios, bilateral renal agenesis, bladder agenesis, single umbilical artery, fusion of the lower limbs and spinal abnormalities; 8 cases of dipus or monopus; 2 cases of apus; and 8 cases of cardiac abnormalities. Subsequent 3D-SUIS showed that there were 9 cases of scoliosis, l0 cases of sacrococ- cygeal vertebra dysplasia, 3 cases of hemivertebra, 1 case of vertebral fusion, 3 cases of spina bifida, and 5 cases of rib abnormalities. 3D-SUIS identified significantly more skeletal abnormalities than did 2D-US, and its accuracy was 79.5% (70/88) compared with 3D-HCT and radiography. 3D-SUIS seems to be a useful complementary method to 2D-US and may improve the accuracy of identifying prenatal skeletal abnormalities related to sirenomelia.展开更多
Based on the working of Lighthill and Hunt et al., in the present paper the author has established the topological rules adapting to analysing the skin-friction lines and the section streamlines in cascades. These rul...Based on the working of Lighthill and Hunt et al., in the present paper the author has established the topological rules adapting to analysing the skin-friction lines and the section streamlines in cascades. These rules are (1) for a rotor cascade without shroud band, the total number of nodal points equals that the saddle points on the skin-friction line vector fields in eachpitch range; (2) for an annular or straight cascade with no-clearances at blade ends, the total number of saddle points is two more than that of nodal points on the skin-friction line fields in a pitch; (3) the total number of saddles in the secondary flow fields on cross-sections in cascade is one less than that of nodes; (4) in the section streamline vector fields on a meridian surface penetrating a flow passage, and on leading and trailing edge sections, the total number of nodes is equal to that of saddles; (5) on the streamline vector fields of a blade-to-blade surface, the total number of nodes is one less than that of saddles.展开更多
BACKGROUND Liver abscess is a common clinical liver disease mainly caused by suppurative bacteria or amoebae,with early clinical signs of chills,high fever,jaundice,and other symptoms.Establishing its early diagnosis ...BACKGROUND Liver abscess is a common clinical liver disease mainly caused by suppurative bacteria or amoebae,with early clinical signs of chills,high fever,jaundice,and other symptoms.Establishing its early diagnosis is difficult,which may lead to misdiagnosis.AIM To observe the effects of psychological guidance combined with evidence-based health intervention in patients with liver abscess treated with ultrasound.METHODS A total of 120 patients with bacterial liver abscess admitted to our hospital from May 2018 to February 2021 were selected and divided into groups according to their intervention plan.RESULTS After the intervention,Self-Rating Depression Scale,Self-Rating Anxiety Scale,Self-Perceived Burden Scale(SPBS),and quality of life scores(physical functioning,role physical,bodily pain,general health,vitality,social functioning,role emotional,mental health)were lower than before the intervention in the two groups.The observation group had lower negative sentiment,SPBS,and quality of life scores than the control group.In the observation group,31 and 24 patients had good and general compliance,respectively,with a compliance rate of 91.67%,which was significantly higher than that in the control group.The observation group had significantly lower total incidence of incision infection,abdominal abscess,hemorrhage,and severe abdominal pain than the control group.CONCLUSION Three-dimensional psychological guidance combined with evidence-based health intervention in treating liver abscess can reduce patients’burden and negative emotions,improve patient compliance and quality of life,and reduce complications.展开更多
Objective:To study the changes in three-dimensional power Doppler ultrasound features before and after neoadjuvant chemotherapy for cervical cancer and their relationship with malignant molecule expression.Methods: Th...Objective:To study the changes in three-dimensional power Doppler ultrasound features before and after neoadjuvant chemotherapy for cervical cancer and their relationship with malignant molecule expression.Methods: The patients who were diagnosed with cervical cancer and received neoadjuvant chemotherapy in Wuhan Red Cross Hospital between March 2015 and October 2017 were selected as the cervical cancer group, and the patients who received cervical biopsy and were diagnosed with stage I cervical intraepithelial neoplasia by pathological findings during the same period were selected as the control group. Before biopsy, three-dimensional power Doppler ultrasonography was performed to measure VI, FI and VFI;the tissues of cervical cancer group before and after chemotherapy as well as the biopsy tissues of control group were collected to measure the expression of proliferation genes, invasion genes and angiogenesis genes.Results: The VI, FI and VFI levels as well as the Piwil2 gene (Piwil2), CyclinD1, N-Myc downstream regulated gene 3 (NDRG3), CXC chemokine ligand 5 (CXCL5), cathepsin-L (CAT-L), EGF-containing fibulin-like extracellular matrix protein 1 (EFEMP1), angiotensin (Ang)1, Ang2 and angiopoietin-like protein 4 (ANGPTL4) mRNA expression levels in the tissues of cervical cancer group before and after chemotherapy were all significantly higher than those of control group whereas the thrombospondin 2 (THBS2), Smac gene (Smac), large tumor suppressor kinase 1 (LATS1), reversion-inducing-cysteine-rich protein with kazal motifs (RECK) and plas minogen activator inhibitor 1 (PAI-1) mRNA expression levels in the tissues were all significantly lower than those of control group, and the VI, FI and VFI levels as well as the Piwil2, CyclinD1, NDRG3, CXCL5, CAT-L, EFEMP1, Ang1, Ang2 and ANGPTL4 mRNA expression levels in the tissues of cervical cancer group after chemotherapy were all significantly lower than those before chemotherapy whereas the THBS2, Smac, LATS1, RECK and PAI-1 mRNA expression levels were all significantly higher than those before chemotherapy;the VI, FI and VFI levels in cervical cancer tissues were positively correlated with the Piwil2, CyclinD1, NDRG3, CXCL5, CAT-L, EFEMP1, Ang1, Ang2 and ANGPTL4 mRNA expression levels, and negatively correlated with the THBS2, Smac, LATS1, RECK and PAI-1 mRNA expression levels.Conclusion: The changes in the three-dimensional power Doppler ultrasound parameters before and after neoadjuvant chemotherapy for cervical cancer can reflect the changes in proliferation, invasion and angiogenesis gene expression in the lesions.展开更多
Objective:To investigate the value of two-dimensional ultrasound speckle tracking(2D-STI)and three-dimensional ultrasound speckle tracking(3D-STI)in evaluating myocardial function in children with Kawasaki disease.Met...Objective:To investigate the value of two-dimensional ultrasound speckle tracking(2D-STI)and three-dimensional ultrasound speckle tracking(3D-STI)in evaluating myocardial function in children with Kawasaki disease.Methods 92 children with Kawasaki disease admitted to our hospital from February 2017 to February 2019 were retrospectively analyzed.50 children who underwent 3D-STI examination were taken as observation group and 42 children who underwent 2D-STI examination were taken as control group.The left ventricular systolic function index,storage time and analysis time of the image,the diameter of coronary artery,the strain difference of left ventricular basal segment,middle segment,apical segment and whole segment were observed.Results The levels of left ventricular end-diastolic volume(LVEDV),left ventricular end-systolic volume(LVESV),left ventricular myocardial mass(LVMI)in the observation group were higher than those in the control group(P<0.05),but there was no statistical difference in left ventricular ejection fraction(LVEF)between the two groups(P>0.05).The storage time and analysis time of the image in the observation group were significantly lower than those in the control group(P<0.05).The left coronary artery(LCA)and right coronary artery(RCA)in the observation group were higher than those in the control group(P<0.05).There was no statistical difference between left anterior descending(LAD)in the two groups(P>0.05).The longitudinal peak systolic strain(LS),circumferential peak systolic strain(CS)and radial peak systolic strain(RS)in the observation group were higher than those in the control group(P<0.05).The global longitudinal peak strain(GLS),global circumferential peak strain(GCS)and global radial peak strain(GRS)in the observation group were higher than those in the control group(P<0.05).LS and CS in the middle segment of the observation group were higher than those in the control group(P<0.05).Conclusions Compared with 2D-STI,3D-STI can objectively and accurately reflect the myocardial function of children with Kawasaki disease.展开更多
Objective:To analyze the correlation between real-time three-dimensional ultrasound in diagnosis of left ventricular function, portal hemodynamics and severity of liver function in patients with liver cirrhosis.Method...Objective:To analyze the correlation between real-time three-dimensional ultrasound in diagnosis of left ventricular function, portal hemodynamics and severity of liver function in patients with liver cirrhosis.Methods: 90 patients with cirrhosis admitted to our hospital from January 2017 to December 2018 were enrolled in the cirrhosis group, and the cirrhosis components were group A, B and C according to the Child-Pauh classification criteria. During the same period, 90 healthy subjects who underwent physical examination were selected as the control group;real-time three-dimensional ultrasonography was performed to examine left ventricular function and portal hemodynamic parameters;Pearson correlation was used to analyze left ventricular function, portal hemodynamics and liver. Functional severity relationship.Results: The left heart E and E/A levels in the cirrhosis group were significantly lower than those in the control group (P<0.05), and the A level was significantly higher than the control group (P<0.05). The Dpv and Q levels in the cirrhosis group were significantly higher than those in the healthy control group. The difference was statistically significant (P<0.05), and the level of Vpv was significantly lower than that of healthy controls (P<0.05). There were significant differences in E, A and E/A levels between different Child-Paugh patients (P<0.05). There were significant differences in portal hemodynamics Dpv, Vpv and Q between the different Child-Paugh grades, and the difference was statistically significant (P<0.05);left heart function E and E/A and liver function severity There was a significant negative correlation (P<0.05). There was a significant positive correlation between left cardiac function A and liver function severity (P<0.05). Portal vein hemodynamics Dpv, Vpv and QE were significantly associated with liver function severity. Positive correlation (P<0.05). Conclusion: Real-time three-dimensional ultrasound can effectively detect left ventricular function and portal hemodynamics changes in patients with cirrhosis, and left heart function, portal hemodynamics and liver function severity are significantly correlated.展开更多
AIM: To evaluate the usefulness of three-dimensional (3D) shear-wave elastography (SWE) in assessing the liver ablation volume after radiofrequency (RF) ablation.
Sometimes endometrial polyps,submucosal myomas,and endometrial cancer show similar findings under ultrasonography.The aim of this study was to assess the antidiastole value of blood flow parameters using three-dimensi...Sometimes endometrial polyps,submucosal myomas,and endometrial cancer show similar findings under ultrasonography.The aim of this study was to assess the antidiastole value of blood flow parameters using three-dimensional(3D)power Doppler ultrasonography angiography(PDA)between endometrial cancer and uterine parenchyma lumps.The data of the blood flow indices in 3D-PDA including the vascularization index(VI),flow index(FI),and vascularization flow index(VFI)in 40 patients with endometrial cancer and 41 patients with uterine parenchyma lumps(endometrial polyps and submucosal myomas)were retrospectively analysed and compared utilizing Virtual Organ Computer-aided AnaLysis(VOCAL)software.The results showed that all the blood flow parameters(VI,FI,VFI)were significantly higher in women with endometrial cancer than in those with uterine parenchyma lumps(P<0.001).The area under the curve of ROC of VI,FI,and VFI was 0.98,0.84,and 0.97,respectively.Thus,the best predictor of endometrial carcinoma was VI with a sensitivity of 97.0% and a specificity of 91.0%.The optimal cutoff value of VI was 4.06%.Our data demonstrated that all of the blood flow signal parameters(including VI,FI,and VFI)in 3D power Doppler ultrasonography had significant antidiastole values between endometrial cancer and uterine parenchyma lumps to assist clinicians in properly diagnosing patients.展开更多
Advent in three-dimensional(3D) imaging technology has seen 3D ultrasound establish itself as a useful adjunct complementary to traditional two-dimensional imaging of the female pelvis. This advantage largely arises f...Advent in three-dimensional(3D) imaging technology has seen 3D ultrasound establish itself as a useful adjunct complementary to traditional two-dimensional imaging of the female pelvis. This advantage largely arises from its ability to reconstruct the coronal plane of the uterus, which allows further delineation of many gynecological disorders. 3D imaging of the uterus is now the preferred imaging modality for assessing congenital uterine anomalies and intrauterine device localization. Newer indications include the diagnosis of adenomyosis. It can also add invaluable information to delineate other endometrial and myometrial pathology such as fibroids and endometrial polyps.展开更多
Objectives: This study focused on evaluating the value of transvaginal 3D ultrasound for the diagnosis and prognostic assessment of post-cesarean section uterine diverticulum. Materials and Methods: We retrospectively...Objectives: This study focused on evaluating the value of transvaginal 3D ultrasound for the diagnosis and prognostic assessment of post-cesarean section uterine diverticulum. Materials and Methods: We retrospectively analyzed the data from 32 patients with post-cesarean section uterine diverticulum over three recent years. In all patients, transvaginal 3D ultrasound was used to measure the size of the uterine diverticulum and the thickness of the lower uterine segment (LUS) and myometrium. Patients with a LUS with a myometrial thickness under 4 mm underwent resection and repair surgery;those with a LUS with a myometrial thickness over 4 mm underwent hysteroscopic resection. The postoperative sonograms were compared with preoperative images to evaluate the efficacy of various treatments. Results: The mean length, width and depth of the uterine diverticula were 18.30 ± 2.80 mm, 9.14 ± 3.20 mm and 11.49 ± 2.71 mm, respectively. The average LUS myometrial thickness was 3.40 ± 0.80 mm (with a range of 1.6 mm - 6.3 mm). After surgery, two patients’ sonograms still showed diverticula at the post-cesarean section scar, measuring 6 mm × 7 mm × 6 mm and 6 mm × 8 mm × 4 mm. There were significant differences in the size of uterine diverticula between preoperative and postoperative sonograms (P < 0.05) and the effective rate of surgery was 93.75% (30/32). Conclusions: Transvaginal 3D ultrasound is an accurate method for detecting post-cesarean section uterine diverticulum and is helpful for assessing surgical options and prognosis. The LUS myometrial thickness, which is considered as an optional index of post-cesarean section uterine diverticulum, should be measured routinely.展开更多
Objective:To explore the clinical diagnostic value of color Doppler ultrasound in caesarean section scar healing.Methods: The study time: From December 2016 to November 2017 in our hospital 106 cases of cesarean secti...Objective:To explore the clinical diagnostic value of color Doppler ultrasound in caesarean section scar healing.Methods: The study time: From December 2016 to November 2017 in our hospital 106 cases of cesarean section after cesarean uterine scar diagnosis, Among them, 53 cases were in the test group, and 53 cases were better than those in the control group, All cesarean parturients were examined by color Doppler ultrasound through the transvaginal and transabdominal. The image features and accuracy of the diagnosis were observed.Results: after examination, the distance between the scar site and the internal cervical of the test group was closer than that of the control group, and the proportion of the posterior uterus in the test group was much higher than that in the control group. At the same time, there was no significant difference in the size of uterus, endometrial thickness, and follicular diameter between the two groups of parturients after the color ultrasound examination.Conclusion: for the poor healing uterus incision scar parts after cesarean section. The combination of vaginal and abdominal color Doppler ultrasonography has high accuracy and has a certain guiding role in clinical treatment. It can be widely applied in clinic.展开更多
The mechanical properties of rocks under cyclic and dynamic loading are important research topics for solving the structural stability of large engineering rocks. As underground mining in coal mines goes deeper, groun...The mechanical properties of rocks under cyclic and dynamic loading are important research topics for solving the structural stability of large engineering rocks. As underground mining in coal mines goes deeper, ground stresses are increasing and instability damage of coal rocks by shear loading is frequent. Therefore, in order to investigate the shear mechanical properties and section morphological characteristics of intact coal samples in the direct shear test, the RDS-200 rock direct shear instrument was used to carry out direct shear tests on intact coal samples under different normal stresses, and the shear section was scanned for three-dimensional morphology. The results show that: 1) from the strength characteristics, the peak shear strength of the coal samples increased linearly with increasing normal stress, and the residual shear strength increased logarithmically. 2) In terms of deformation characteristics, the peak shear displacement of the coal sample increases linearly with increasing normal stress, the pre-peak shear stiffness increases logarithmically, and the residual normal displacement decreases linearly. 3) From the morphological characteristics of the shear surface, with the increase of normal stress, the section transitions from high-order undulating to flattening type. The maximum height of the fracture surface profile and kurtosis coefficient of the shear section decreased linearly, and the profile area ratio and root mean square of slope decreased as a power function, i.e. the higher the normal stress, the smaller the undulation of the section, the sharpness of the roughness shape and the roughness coefficient JRC, and the flatter and smoother the section. The findings of this study can help to provide some reference for the evaluation of shear instability occurring in coal bodies under different normal stresses.展开更多
文摘BACKGROUND Numerous variables are linked to the success of vaginal delivery,including the subpubic arch angle(SPAA)during labor,the importance of which has not yet been fully elucidated.AIM To examine the SPAA distributional characteristics and to ascertain SPAA’s ability to predict the type and duration of labor.METHODS We determined the SPAA and analyzed the corresponding data.We also evaluated the relationship between the SPAA and the mode of delivery and the duration of labor by regression.The present study comprised a total of 301 pregnant women who had given birth at Beijing Tiantan Hospital of the Capital Medical University between January and December of 2021.RESULTS Our analysis of 301 pregnant women revealed that the SPAA measured using three-dimensional trans-perineal ultrasound had a minimum angle of 81°and a maximum angle of 122.2°.The angle in the normal vaginal delivery group was greater than that in the labor cesarean group(P=0.000).The SPAA was a highly significant positive predictor of normal vaginal delivery(P=0.000)with an area under the curve of 0.782(P=0.000;95%CI:0.717-0.848).We found the length of the second stage of labor to be positively influenced by the SPAA using linear regression analysis(P=0.045).CONCLUSION The SPAA was a highly significant positive predictor of normal vaginal delivery.The length of the second stage of labor and normal vaginal birth were predicted by SPAA.
基金Supported by the State administration of Traditional Secretary and the nanjing health Bureau,no.YKK12142
文摘AIM To assess the role of three-dimensional endoanal ultrasound (3D-EAUS) for morphological assessment of the anal sphincter of female patients with chronic proctalgia (CP). METHODS In this unmatched case control study, 30 consecutive female patients with CP and 25 normal women (control group) were enrolled. 3D-EAUS was performed in all subjects. Thickness and length of internal anal sphincter (IAS), thickness of puborectalis muscle (PR), length of the external anal sphincter (EAS) plus PR, and puborectalis angle were measured and compared between the two groups. RESULTS Patients with CP had significantly shorter IAS length and greater PR thickness, as compared to those in normal individuals (26.28 +/- 3.59 mm vs 28.87 +/- 4.84 mm, P < 0.05 and 9.67 +/- 1.57 mm vs 8.85 +/- 0.97 mm, P < 0.05, respectively). No significant between-group differences were observed with respect to IAS thickness and the EAS plus PR length (P > 0.05). Puborectalis angle in the CP group was significantly decreased, both in resting (88.23 degrees +/- 1.81 degrees vs 89.94 degrees +/- 2.07 degrees in control group, P < 0.05) and straining (88.47 degrees +/- 3.32 degrees vs 90.72 degrees +/- 1.87 degrees in control group, P < 0.05) phases, which suggest the presence of paradoxical contraction of PR in patients with CP. In the CP group, no significant difference in puborectalis angle was observed between the resting and straining phases (88.23 degrees +/- 1.81 degrees vs 88.47 degrees +/- 3.32 degrees respectively, P > 0.05). CONCLUSION The association of greater PR thickness and paradoxical contraction of PR with CP suggest their potential value as markers of CP.
文摘This study assessed the clinical application of transvaginal three-dimensional ultrasound (3D TVUS) in the diagnosis of congenital uterine malformation. A retrospective study was performed on 62 patients with congenital uterine malformation confirmed hysteroscopically and/or laparoscopically. The patients were subjected to transvaginal two-dimensional ultrasound (2D TVUS) and 3D TVUS. The accuracy rate was compared between the two methods. The accuracy rate of 3D TVUS was (98.38%, 61/62), higher than that of 2D TVUS (80.65%, 50/62). 3D TVUS coronal plane imaging could demon- strate the internal shape of the endometrial cavity and the external contour of the uterine fundus. It al- lowed accurate measurement on the coronary plane, and could three-dimensionally show the image of cervical tube, thereby providing information for the diagnosis of some complex uterine malformation. 3D TVUS imaging can obtain comprehensive information of the uterus malformation, and it is superior to 2D TVUS for the diagnosis of congenital uterine malformations, especially complex uterine anomaly.
文摘The purpose of this study was to evaluate the outcome of patients with unresectable hepatocellular carcinoma(HCC) treated by sequential therapy of transcatheter arterial chemoembolization(TACE),three-dimensional conformal radiotherapy(3-DCRT) and high-intensity focused ultrasound(HIFU).From October,2005 to September,2010,120 patients with unresectable HCC received the sequential treatments of several courses of TACE followed in 2-4 weeks by 3-DCRT and then a single session of HIFU with a curative intent.The median tumor irradiation dose was 40 Gy.Tumor response,toxicity and overall survival rate were analyzed.Clinicopathologic factors affecting the primary technique effectiveness and overall survival rates were investigated by univariate analysis or multivariate analysis.All 120 HCC patients were followed up by the last follow-up time.Among these patients,hepatic toxicities due to treatment were notable in 9 cases.Gastrointestinal bleeding after the overall treatment occurred in 2 cases,leukopenia of grade III was detected in 1 case,radiation-induced liver disease(RILD) was observed in 2 patients,and first-and second-degree skin burn around the HIFU treatment zone were observed in 2 patients and 1 patient,respectively.Among 120 patients,23,83 and 14 cases achieved partial response,stable disease and progressive disease,respectively.The overall survival rates at 1 year,3 years and 5 years were 70%,35% and 15%,respectively,with a median survival time of 26 months.Both Child-Pugh liver function grading and radiation dose were determined to be independent predictors for overall survival revealed by the multivariate analysis.It is concluded that the sequential therapy of TACE,3-DCRT and HIFU is a promising therapeutic regimen for unresectable HCC.
基金Natural Science Research Plan forJiangsu Colleges, No.05KJB180105 Postgraduate Innovation Cultivating Projectin Jiangsu Province, No.CX07s_035z
文摘BACKGROUND: It is not possible to reconstruct the inner structure of the spinal cord, such as gray matter and spinal tracts, from the Visual Human Project database or CT and MRI databases, due to low image resolution and contrast in macrosection images. OBJECTIVE: To explore a semi-automatic computerized three-dimensional (3D) reconstruction of human spinal cord based on histological serial sections, in order to solve issues such as low contrast. DESIGN, TIME AND SETTING: An experimental study combining serial section techniques and 3D reconstruction, performed in the laboratory of Human Anatomy and Histoembryology at the Medical School of Nantong University during January to April 2008. SETTING: Department of Anatomy, Institute of Neurobiology, Jiangsu Province Key Laboratory of Neural Regeneration, Laboratory of Image Engineering. MATERIALS: A human lumbar spinal cord segment from fresh autopsy material of an adult male. METHODS: After 4% paraformaldehyde fixation for three days, serial sections of the lumbar spinal cord were cut on a Leica cryostat and mounted on slides in sequence, with eight sections aligned separately on each slide. All sections were stained with Luxol Fast Blue to reveal myelin sheaths. After gradient dehydration and clearing, the stained slides were coverslipped. Sections were observed and images recorded under a light microscope using a digital camera. Six images were acquired at x25 magnification and automatically stitched into a complete section image. After all serial images were obtained, 96 complete serial images of the human lumbar cord segment were automatically processed with "Curves", "Autocontrast", "Gray scale 8 bit", "Invert", "Image resize to 50%" steps using Photoshop 7.0 software. All images were added in order into 3D-DOCTOR 4.0 software as a stack, where serial images were automatically realigned with neighboring images and semi-automatically segmented for white matter and gray matter. Finally, simple surface and volume reconstruction were completed on a personal computer. The reconstructed human lumbar spinal cord segment was interactively observed, cut, and measured. MAIN OUTCOME MEASURES: The reconstructed human lumbar spinal cord segment. RESULTS: Compared with serial images obtained from other image modalities, such as CT, MRI, and macrosections from The Visual Human Project database, the Luxol Fast Blue stained histological serial section images exhibited higher resolution and contrast between gray and white matter. Image processing and 3D reconstruction steps were semi-automatically performed with related software. The 3D reconstructed human lumbar cord segment were observed, cut, and measured on a PC. CONCLUSION: A semi-automatically computerized method, based on histological serial sections, is an effective way to 3D-reconstruct the human spinal cord.
文摘Summary: This study sought to evaluate the contribution of two-dimensional ultrasound (2D-US) and three-dimensional skeletal imaging ultrasound (3D-SUIS) in the prenatal diagnosis of sirenomelia. Be- tween September 2010 and April 2014, a prospective study was conducted in a single referral center using 3D-SU1S performed after 2D-US in 10 cases of sirenomelia. Diagnostic accuracy and detailed findings were compared with postnatal three-dimensional helical computed tomography (3D-HCT), radiological findings and autopsy. Pregnancy was terminated in all 10 sirenomelia cases, including 9 singletons and I conjoined twin pregnancy, for a total of 5 males and 5 females. These cases of sirenomelia were deter- mined by autopsy and/or chromosomal examination. Initial 2D-US showed that there were 10 cases of oligohydranmios, bilateral renal agenesis, bladder agenesis, single umbilical artery, fusion of the lower limbs and spinal abnormalities; 8 cases of dipus or monopus; 2 cases of apus; and 8 cases of cardiac abnormalities. Subsequent 3D-SUIS showed that there were 9 cases of scoliosis, l0 cases of sacrococ- cygeal vertebra dysplasia, 3 cases of hemivertebra, 1 case of vertebral fusion, 3 cases of spina bifida, and 5 cases of rib abnormalities. 3D-SUIS identified significantly more skeletal abnormalities than did 2D-US, and its accuracy was 79.5% (70/88) compared with 3D-HCT and radiography. 3D-SUIS seems to be a useful complementary method to 2D-US and may improve the accuracy of identifying prenatal skeletal abnormalities related to sirenomelia.
文摘Based on the working of Lighthill and Hunt et al., in the present paper the author has established the topological rules adapting to analysing the skin-friction lines and the section streamlines in cascades. These rules are (1) for a rotor cascade without shroud band, the total number of nodal points equals that the saddle points on the skin-friction line vector fields in eachpitch range; (2) for an annular or straight cascade with no-clearances at blade ends, the total number of saddle points is two more than that of nodal points on the skin-friction line fields in a pitch; (3) the total number of saddles in the secondary flow fields on cross-sections in cascade is one less than that of nodes; (4) in the section streamline vector fields on a meridian surface penetrating a flow passage, and on leading and trailing edge sections, the total number of nodes is equal to that of saddles; (5) on the streamline vector fields of a blade-to-blade surface, the total number of nodes is one less than that of saddles.
文摘BACKGROUND Liver abscess is a common clinical liver disease mainly caused by suppurative bacteria or amoebae,with early clinical signs of chills,high fever,jaundice,and other symptoms.Establishing its early diagnosis is difficult,which may lead to misdiagnosis.AIM To observe the effects of psychological guidance combined with evidence-based health intervention in patients with liver abscess treated with ultrasound.METHODS A total of 120 patients with bacterial liver abscess admitted to our hospital from May 2018 to February 2021 were selected and divided into groups according to their intervention plan.RESULTS After the intervention,Self-Rating Depression Scale,Self-Rating Anxiety Scale,Self-Perceived Burden Scale(SPBS),and quality of life scores(physical functioning,role physical,bodily pain,general health,vitality,social functioning,role emotional,mental health)were lower than before the intervention in the two groups.The observation group had lower negative sentiment,SPBS,and quality of life scores than the control group.In the observation group,31 and 24 patients had good and general compliance,respectively,with a compliance rate of 91.67%,which was significantly higher than that in the control group.The observation group had significantly lower total incidence of incision infection,abdominal abscess,hemorrhage,and severe abdominal pain than the control group.CONCLUSION Three-dimensional psychological guidance combined with evidence-based health intervention in treating liver abscess can reduce patients’burden and negative emotions,improve patient compliance and quality of life,and reduce complications.
文摘Objective:To study the changes in three-dimensional power Doppler ultrasound features before and after neoadjuvant chemotherapy for cervical cancer and their relationship with malignant molecule expression.Methods: The patients who were diagnosed with cervical cancer and received neoadjuvant chemotherapy in Wuhan Red Cross Hospital between March 2015 and October 2017 were selected as the cervical cancer group, and the patients who received cervical biopsy and were diagnosed with stage I cervical intraepithelial neoplasia by pathological findings during the same period were selected as the control group. Before biopsy, three-dimensional power Doppler ultrasonography was performed to measure VI, FI and VFI;the tissues of cervical cancer group before and after chemotherapy as well as the biopsy tissues of control group were collected to measure the expression of proliferation genes, invasion genes and angiogenesis genes.Results: The VI, FI and VFI levels as well as the Piwil2 gene (Piwil2), CyclinD1, N-Myc downstream regulated gene 3 (NDRG3), CXC chemokine ligand 5 (CXCL5), cathepsin-L (CAT-L), EGF-containing fibulin-like extracellular matrix protein 1 (EFEMP1), angiotensin (Ang)1, Ang2 and angiopoietin-like protein 4 (ANGPTL4) mRNA expression levels in the tissues of cervical cancer group before and after chemotherapy were all significantly higher than those of control group whereas the thrombospondin 2 (THBS2), Smac gene (Smac), large tumor suppressor kinase 1 (LATS1), reversion-inducing-cysteine-rich protein with kazal motifs (RECK) and plas minogen activator inhibitor 1 (PAI-1) mRNA expression levels in the tissues were all significantly lower than those of control group, and the VI, FI and VFI levels as well as the Piwil2, CyclinD1, NDRG3, CXCL5, CAT-L, EFEMP1, Ang1, Ang2 and ANGPTL4 mRNA expression levels in the tissues of cervical cancer group after chemotherapy were all significantly lower than those before chemotherapy whereas the THBS2, Smac, LATS1, RECK and PAI-1 mRNA expression levels were all significantly higher than those before chemotherapy;the VI, FI and VFI levels in cervical cancer tissues were positively correlated with the Piwil2, CyclinD1, NDRG3, CXCL5, CAT-L, EFEMP1, Ang1, Ang2 and ANGPTL4 mRNA expression levels, and negatively correlated with the THBS2, Smac, LATS1, RECK and PAI-1 mRNA expression levels.Conclusion: The changes in the three-dimensional power Doppler ultrasound parameters before and after neoadjuvant chemotherapy for cervical cancer can reflect the changes in proliferation, invasion and angiogenesis gene expression in the lesions.
基金Shaanxi key research and development plan(No.2019SF-211).
文摘Objective:To investigate the value of two-dimensional ultrasound speckle tracking(2D-STI)and three-dimensional ultrasound speckle tracking(3D-STI)in evaluating myocardial function in children with Kawasaki disease.Methods 92 children with Kawasaki disease admitted to our hospital from February 2017 to February 2019 were retrospectively analyzed.50 children who underwent 3D-STI examination were taken as observation group and 42 children who underwent 2D-STI examination were taken as control group.The left ventricular systolic function index,storage time and analysis time of the image,the diameter of coronary artery,the strain difference of left ventricular basal segment,middle segment,apical segment and whole segment were observed.Results The levels of left ventricular end-diastolic volume(LVEDV),left ventricular end-systolic volume(LVESV),left ventricular myocardial mass(LVMI)in the observation group were higher than those in the control group(P<0.05),but there was no statistical difference in left ventricular ejection fraction(LVEF)between the two groups(P>0.05).The storage time and analysis time of the image in the observation group were significantly lower than those in the control group(P<0.05).The left coronary artery(LCA)and right coronary artery(RCA)in the observation group were higher than those in the control group(P<0.05).There was no statistical difference between left anterior descending(LAD)in the two groups(P>0.05).The longitudinal peak systolic strain(LS),circumferential peak systolic strain(CS)and radial peak systolic strain(RS)in the observation group were higher than those in the control group(P<0.05).The global longitudinal peak strain(GLS),global circumferential peak strain(GCS)and global radial peak strain(GRS)in the observation group were higher than those in the control group(P<0.05).LS and CS in the middle segment of the observation group were higher than those in the control group(P<0.05).Conclusions Compared with 2D-STI,3D-STI can objectively and accurately reflect the myocardial function of children with Kawasaki disease.
文摘Objective:To analyze the correlation between real-time three-dimensional ultrasound in diagnosis of left ventricular function, portal hemodynamics and severity of liver function in patients with liver cirrhosis.Methods: 90 patients with cirrhosis admitted to our hospital from January 2017 to December 2018 were enrolled in the cirrhosis group, and the cirrhosis components were group A, B and C according to the Child-Pauh classification criteria. During the same period, 90 healthy subjects who underwent physical examination were selected as the control group;real-time three-dimensional ultrasonography was performed to examine left ventricular function and portal hemodynamic parameters;Pearson correlation was used to analyze left ventricular function, portal hemodynamics and liver. Functional severity relationship.Results: The left heart E and E/A levels in the cirrhosis group were significantly lower than those in the control group (P<0.05), and the A level was significantly higher than the control group (P<0.05). The Dpv and Q levels in the cirrhosis group were significantly higher than those in the healthy control group. The difference was statistically significant (P<0.05), and the level of Vpv was significantly lower than that of healthy controls (P<0.05). There were significant differences in E, A and E/A levels between different Child-Paugh patients (P<0.05). There were significant differences in portal hemodynamics Dpv, Vpv and Q between the different Child-Paugh grades, and the difference was statistically significant (P<0.05);left heart function E and E/A and liver function severity There was a significant negative correlation (P<0.05). There was a significant positive correlation between left cardiac function A and liver function severity (P<0.05). Portal vein hemodynamics Dpv, Vpv and QE were significantly associated with liver function severity. Positive correlation (P<0.05). Conclusion: Real-time three-dimensional ultrasound can effectively detect left ventricular function and portal hemodynamics changes in patients with cirrhosis, and left heart function, portal hemodynamics and liver function severity are significantly correlated.
文摘AIM: To evaluate the usefulness of three-dimensional (3D) shear-wave elastography (SWE) in assessing the liver ablation volume after radiofrequency (RF) ablation.
基金This research was supported by grants from the National Natural Science Foundation of China(No.81501530)Hubei Province Health and Family Planning Scientific Research Project(No.WJ2019M130).
文摘Sometimes endometrial polyps,submucosal myomas,and endometrial cancer show similar findings under ultrasonography.The aim of this study was to assess the antidiastole value of blood flow parameters using three-dimensional(3D)power Doppler ultrasonography angiography(PDA)between endometrial cancer and uterine parenchyma lumps.The data of the blood flow indices in 3D-PDA including the vascularization index(VI),flow index(FI),and vascularization flow index(VFI)in 40 patients with endometrial cancer and 41 patients with uterine parenchyma lumps(endometrial polyps and submucosal myomas)were retrospectively analysed and compared utilizing Virtual Organ Computer-aided AnaLysis(VOCAL)software.The results showed that all the blood flow parameters(VI,FI,VFI)were significantly higher in women with endometrial cancer than in those with uterine parenchyma lumps(P<0.001).The area under the curve of ROC of VI,FI,and VFI was 0.98,0.84,and 0.97,respectively.Thus,the best predictor of endometrial carcinoma was VI with a sensitivity of 97.0% and a specificity of 91.0%.The optimal cutoff value of VI was 4.06%.Our data demonstrated that all of the blood flow signal parameters(including VI,FI,and VFI)in 3D power Doppler ultrasonography had significant antidiastole values between endometrial cancer and uterine parenchyma lumps to assist clinicians in properly diagnosing patients.
文摘Advent in three-dimensional(3D) imaging technology has seen 3D ultrasound establish itself as a useful adjunct complementary to traditional two-dimensional imaging of the female pelvis. This advantage largely arises from its ability to reconstruct the coronal plane of the uterus, which allows further delineation of many gynecological disorders. 3D imaging of the uterus is now the preferred imaging modality for assessing congenital uterine anomalies and intrauterine device localization. Newer indications include the diagnosis of adenomyosis. It can also add invaluable information to delineate other endometrial and myometrial pathology such as fibroids and endometrial polyps.
文摘Objectives: This study focused on evaluating the value of transvaginal 3D ultrasound for the diagnosis and prognostic assessment of post-cesarean section uterine diverticulum. Materials and Methods: We retrospectively analyzed the data from 32 patients with post-cesarean section uterine diverticulum over three recent years. In all patients, transvaginal 3D ultrasound was used to measure the size of the uterine diverticulum and the thickness of the lower uterine segment (LUS) and myometrium. Patients with a LUS with a myometrial thickness under 4 mm underwent resection and repair surgery;those with a LUS with a myometrial thickness over 4 mm underwent hysteroscopic resection. The postoperative sonograms were compared with preoperative images to evaluate the efficacy of various treatments. Results: The mean length, width and depth of the uterine diverticula were 18.30 ± 2.80 mm, 9.14 ± 3.20 mm and 11.49 ± 2.71 mm, respectively. The average LUS myometrial thickness was 3.40 ± 0.80 mm (with a range of 1.6 mm - 6.3 mm). After surgery, two patients’ sonograms still showed diverticula at the post-cesarean section scar, measuring 6 mm × 7 mm × 6 mm and 6 mm × 8 mm × 4 mm. There were significant differences in the size of uterine diverticula between preoperative and postoperative sonograms (P < 0.05) and the effective rate of surgery was 93.75% (30/32). Conclusions: Transvaginal 3D ultrasound is an accurate method for detecting post-cesarean section uterine diverticulum and is helpful for assessing surgical options and prognosis. The LUS myometrial thickness, which is considered as an optional index of post-cesarean section uterine diverticulum, should be measured routinely.
文摘Objective:To explore the clinical diagnostic value of color Doppler ultrasound in caesarean section scar healing.Methods: The study time: From December 2016 to November 2017 in our hospital 106 cases of cesarean section after cesarean uterine scar diagnosis, Among them, 53 cases were in the test group, and 53 cases were better than those in the control group, All cesarean parturients were examined by color Doppler ultrasound through the transvaginal and transabdominal. The image features and accuracy of the diagnosis were observed.Results: after examination, the distance between the scar site and the internal cervical of the test group was closer than that of the control group, and the proportion of the posterior uterus in the test group was much higher than that in the control group. At the same time, there was no significant difference in the size of uterus, endometrial thickness, and follicular diameter between the two groups of parturients after the color ultrasound examination.Conclusion: for the poor healing uterus incision scar parts after cesarean section. The combination of vaginal and abdominal color Doppler ultrasonography has high accuracy and has a certain guiding role in clinical treatment. It can be widely applied in clinic.
文摘The mechanical properties of rocks under cyclic and dynamic loading are important research topics for solving the structural stability of large engineering rocks. As underground mining in coal mines goes deeper, ground stresses are increasing and instability damage of coal rocks by shear loading is frequent. Therefore, in order to investigate the shear mechanical properties and section morphological characteristics of intact coal samples in the direct shear test, the RDS-200 rock direct shear instrument was used to carry out direct shear tests on intact coal samples under different normal stresses, and the shear section was scanned for three-dimensional morphology. The results show that: 1) from the strength characteristics, the peak shear strength of the coal samples increased linearly with increasing normal stress, and the residual shear strength increased logarithmically. 2) In terms of deformation characteristics, the peak shear displacement of the coal sample increases linearly with increasing normal stress, the pre-peak shear stiffness increases logarithmically, and the residual normal displacement decreases linearly. 3) From the morphological characteristics of the shear surface, with the increase of normal stress, the section transitions from high-order undulating to flattening type. The maximum height of the fracture surface profile and kurtosis coefficient of the shear section decreased linearly, and the profile area ratio and root mean square of slope decreased as a power function, i.e. the higher the normal stress, the smaller the undulation of the section, the sharpness of the roughness shape and the roughness coefficient JRC, and the flatter and smoother the section. The findings of this study can help to provide some reference for the evaluation of shear instability occurring in coal bodies under different normal stresses.