期刊文献+
共找到2,046篇文章
< 1 2 103 >
每页显示 20 50 100
Asymmetric Three-Phase Cascading Trinary-DC Source Multilevel Inverter Topologies for Variable Frequency PWM
1
作者 G. Irusapparajan D. Periyaazhagar 《Circuits and Systems》 2016年第4期506-519,共14页
Asymmetric three-phase cascading Trinary-DC source Multilevel Inverter which can achieve reduced harmonics and superior root mean square (RMS) values of the output voltage is proposed. This topology can achieve cascad... Asymmetric three-phase cascading Trinary-DC source Multilevel Inverter which can achieve reduced harmonics and superior root mean square (RMS) values of the output voltage is proposed. This topology can achieve cascaded full bridge inverter operation with dissimilar (unequal) DC Source and it is fired by using variable frequency pulse with modulation technique as a switching strategy. This pulse width modulation switching strategy has a newly adopted multicarrier single reference technique. The performance parameter factors like Form Factor (FF), Crest Factor (CF), Total Harmonic Distortion (THD) and fundamental RMS output voltage (V<sub>RMS</sub>) are estimated by using proposed asymmetrical three-phase cascading multilevel inverter for several modulation indices (0.8 - 1). The research study carries with MATLAB/SIMULINK based simulation and experimental results obtained using appropriate prototype (test board) to prove the viability of the proposed concept. 展开更多
关键词 Trinary Multilevel inverter Variable frequency Pulse Width Modulation Total Harmonic Distortions Trinary-DC Source Distortion Factor
下载PDF
Simplified Model Predictive Current Control for Dual Three-phase PMSM with Low Computation Burden and Switching Frequency
2
作者 Huawei Zhou Xiaolong Xiang +1 位作者 Yibo Li Tao Tao 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第4期447-454,共8页
Finite-control-set model predictive control(FCSMPC)has advantages of multi-objective optimization and easy implementation.To reduce the computational burden and switching frequency,this article proposed a simplified M... Finite-control-set model predictive control(FCSMPC)has advantages of multi-objective optimization and easy implementation.To reduce the computational burden and switching frequency,this article proposed a simplified MPC for dual three-phase permanent magnet synchronous motor(DTPPMSM).The novelty of this method is the decomposition of prediction function and the switching optimization algorithm.Based on the decomposition of prediction function,the current increment vector is obtained,which is employed to select the optimal voltage vector and calculate the duty cycle.Then,the computation burden can be reduced and the current tracking performance can be maintained.Additionally,the switching optimization algorithm was proposed to optimize the voltage vector action sequence,which results in lower switching frequency.Hence,this control strategy can not only reduce the computation burden and switching frequency,but also maintain the steady-state and dynamic performance.The simulation and experimental results are presented to verify the feasibility of the proposed strategy. 展开更多
关键词 Computation time Current increment vector Dual three-phase permanent magnet synchronous motor(DTPPMSM) Model predictive current control(MPCC) Switching frequency
下载PDF
THREE-PHASE BRIDGE INVERTER FOR 9kW DOUBLY SALIENT PERMANENT MAGNET MOTOR
3
作者 黄伟君 秦海鸿 +1 位作者 王慧贞 严仰光 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2006年第1期27-33,共7页
The three-phase bridge inverter is used as the converter topology in the power controller for a 9 kW doubly salient permanent magnet (DSPM) motor. Compared with common three-phase bridge inverters, the proposed inve... The three-phase bridge inverter is used as the converter topology in the power controller for a 9 kW doubly salient permanent magnet (DSPM) motor. Compared with common three-phase bridge inverters, the proposed inverter works under more complicated conditions with different principles for special winding back EMFs, position signals of hall sensors, and the given mode of switches. The ideal steady driving principles of the inverter for the motor are given. The working state with asymmetric winding back EMFs, inaccurate position signals of hall sensors, and the changing input voltage is analyzed. Finally, experimental results vertify that the given anal ysis is correct. 展开更多
关键词 doubly salient permanent magnet motor three-phase bridge inverter winding back EMF position signal of hall sensor input voltage
下载PDF
A NOVEL AERONAUTICAL STATIC INVERTER WITH HIGH FREQUENCY PULSE DC LINK
4
作者 陈道炼 刘志政 +1 位作者 严仰光 胡育文 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 1999年第1期48-54,共7页
A new combined soft switching technique and a novel topology of aeronautical static inverter with high frequency pulse dc link are proposed in this paper, namely an electrical isolated converter can realize soft swi... A new combined soft switching technique and a novel topology of aeronautical static inverter with high frequency pulse dc link are proposed in this paper, namely an electrical isolated converter can realize soft switching of two stage cascade converters. It lays technical foundation for high power density, high efficiency and low cost aeronautical static inverter. The operation and design approach of this topology are carefully analyzed and studied. The validity of this topology is verified by simulation and test. 展开更多
关键词 inverterS high frequency links active clamp circuits combined soft switching techniques three state discrete pulse modulation
下载PDF
Coordinated Control of Second-order Harmonic Voltage and Current Fluctuations in Cascaded H-bridge Inverter with Supercapacitor and DC-DC Stage at Variable Output Frequencies
5
作者 Ye Zhang Zixin Li +3 位作者 Fanqiang Gao Jinhao Zhang Cong Zhao Yaohua Li 《CES Transactions on Electrical Machines and Systems》 EI CSCD 2024年第4期481-492,共12页
In the cascaded H-bridge inverter(CHBI)with supercapacitor and dc-dc stage,inherent second-order harmonic power flows through each submodule(SM),causing fluctuations in both the dc-link voltage and the dc-dc current.T... In the cascaded H-bridge inverter(CHBI)with supercapacitor and dc-dc stage,inherent second-order harmonic power flows through each submodule(SM),causing fluctuations in both the dc-link voltage and the dc-dc current.There exist limitations in handling these fluctuations at variable output frequencies when employing proportional-integral(PI)control to the dc-dc stage.This paper aims to coordinately control these second-order harmonic voltage and current fluctuations in the CHBI.The presented method configures a specific second-order harmonic voltage reference,equipped with a maximum voltage fluctuation constraint and a suitable phase,for the dc-dc stage.A PI-resonant controller is used to track the configured reference.This allows for regulating the second-order harmonic fluctuation in the average dc-link voltage among the SMs within a certain value.Importantly,the second-order harmonic fluctuation in the dc-dc current can also be reduced.Simulation and experimental results demonstrate the effectiveness of the presented method. 展开更多
关键词 Cascaded H-bridge inverter(CHBI) DC-DC current reduction Second-order harmonic fluctuation Variable frequencies Proportional-integral-resonant
下载PDF
A new three-phase 5-level current-source inverter 被引量:4
6
作者 BAO Jian-yu BAI Zhi-hong +1 位作者 WANG Qing-song ZHANG Zhong-chao 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2006年第12期1973-1978,共6页
The new three-phase 5-level current-source inverter (CSI) proposed in this paper was developed by connecting three separate single-phase 5-level CSIs in series, and its operational principle was analyzed. There are tw... The new three-phase 5-level current-source inverter (CSI) proposed in this paper was developed by connecting three separate single-phase 5-level CSIs in series, and its operational principle was analyzed. There are two major problems existing in current-source multilevel inverters, one is the complex PWM control method (2-logic to 3-logic conversion), and the other is the problem of current-unbalance between different levels. A simple current-balance control method via DC current feedback is applied in each single-phase 5-level CSI cell to implement the current-balance control between different levels. And to reduce the output current harmonics, POD PWM control technique was used. Simulation and experimental results showed that this new three-phase 5-level CSI topology operates correctly. 展开更多
关键词 three-phase Current-source inverter (CSI) 5-level HARMONICS POD PWM
下载PDF
Control strategy of LCL-type three-phase photovoltaic grid connected inverter 被引量:2
7
作者 WANG Si-hua WANG Jin-qiang 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2019年第3期254-265,共12页
The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control str... The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control strategy is presented, which is composed of an inner loop of capacitor current feedforward, an outer loop of grid-current feedforward and feedforward of grid voltage. The limitations and steps of parameters design for LCL filter are analyzed. Meanwhile, the capacitor current loop is employed to damp the resonant peak caused by the LCL filter and enhance the stability. The properties of different controllers are analyzed and compared, thereinto quasi-proportional-rasonant (PR) controller realizes the control with zero steady-state error of AC variables in static coordinates. In order to suppress the current distortion effected by the background harmonics in grid voltage, the feed-forward function is calculated for the grid-connected inverter with an LCL filter. After simplifying the block diagram, a full-feedforward control strategy for grid voltage is proposed. Theoretical analysis and Matlab/Simulink simulation results show that the proposed method has the advantages of high steady accuracy, fast dynamic response and strong robustness. 展开更多
关键词 three-phase grid-connected inverter LCL filter active damping quasi-proportional-resonant (PR) control full-feedforward of grid voltages
下载PDF
Inverter-Based Diesel Generator Emulator for the Study of Frequency Variations in a Laboratory-Scale Autonomous Power System
8
作者 Miguel Torres Luiz A. C. Lopes 《Energy and Power Engineering》 2013年第3期274-283,共10页
This paper presents the modeling, simulation and practical implementation of an inverter-based diesel generator emulator. The main purpose of this emulator is for the study of frequency variations in diesel-based auto... This paper presents the modeling, simulation and practical implementation of an inverter-based diesel generator emulator. The main purpose of this emulator is for the study of frequency variations in diesel-based autonomous power systems in a laboratory environment where the operation of a real diesel generator is not possible. The emulator basically consists in a voltage source inverter with a second order output filter which voltage references are given by the model of the diesel generator. The control of the emulator is based on the digital signal processor TMS320F2812, where the mathematical models of the diesel generator and the control of the inverter are computed in real-time. Parameters for the model were obtained from commercially available components. Experimental results for different values of speed droop showed that the emulator achieves a satisfactory performance in the transient and stationary response. For the stationary response, the measured frequency deviates from theoretical values with a mean absolute error of: 0.06 Hz for 0% droop, 0.037 Hz for 3% droop, and 0.087 Hz for 5% droop. For the transient response, the measured frequency nadir deviates from simulations in: 0.05 Hz for 0% droop, 0.02 Hz for 3% droop, and 0.1 Hz for 5% droop. 展开更多
关键词 DIESEL GENERATOR EMULATOR inverter frequency Control Mini-Grid
下载PDF
The Research of Three-phase Boost/Buck-boost DC-AC Inverter
9
作者 Xiangli Li Zhaoyang Yan +1 位作者 Yanni Gao Hanhong Qi 《Energy and Power Engineering》 2013年第4期906-913,共8页
This paper presents a new inverter based on three-phase Boost/Buck-boost single-stage inverter. The basic configuration of the new topology and their fundamental principle are firstly introduced, the method of design ... This paper presents a new inverter based on three-phase Boost/Buck-boost single-stage inverter. The basic configuration of the new topology and their fundamental principle are firstly introduced, the method of design double-loop controller and sliding mode controller are clarified, analyzed and compared in the following. Finally the validity and feasibility of the new topology are tested by simulation. The results indicate that regulation of the voltage transfer ratio and output frequency can be realized optionally by the new converter, furthermore the harmonic distortion of waveform is low. So the inherent drawback of low voltage transfer ratio of traditional converter is effectively settled. This study may provide inspiration for further engineering application. 展开更多
关键词 three-phase BOOST SINGLE-STAGE inverter three-phase BUCK-BOOST SINGLE-STAGE inverter Double-loop CONTROLLER Sliding Mode CONTROLLER
下载PDF
The Control Technology Research of the Z-source Three-phase Four-bridge Arm Inverter
10
作者 Xiangli Li Zhaoyang Yan +2 位作者 Keke Pan Chenghao Ma Hanhong Qi 《Energy and Power Engineering》 2013年第4期733-739,共7页
Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth le... Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth leg of the three-phase four-leg inverter so the three-phase four-leg inverter can work with unbalanced load. This paper presents a Z-source three-phase four-leg inverter which combines a Z-source network with three-phase four-leg inverter. The circuit uses simple SPWM modulation technique and the fourth bridge arm uses fully compensated control method. The inverter can maintain a symmetrical output voltage when the proposed scheme under the unbalanced load. 展开更多
关键词 Z-SOURCE inverter three-phase FOUR-LEG inverter Unbalanced Load Imbalanced VOLTAGE
下载PDF
The improved PAC method for a three-phase PWM grid-connected inverter
11
作者 李杰 马祎炜 +2 位作者 陈国呈 王得利 俞俊杰 《Journal of Shanghai University(English Edition)》 CAS 2008年第6期560-564,共5页
In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response w... In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response when system starts up, the starting voltage prediction control and the current feed-forward control are proposed and used, which improve the dynamic performance of the system in the PAC.The experimental results carried out on a three-phase grid-connected inverter proved the validity of the proposed method. 展开更多
关键词 three-phase pulse width modulation (PWM) grid-connected inverter phase and amplitude control (PAC) starting voltage prediction control current feed-forward control
下载PDF
Modeling and Analysis of Variable Frequency Inverted Sine PWM Technique for a Hybrid Cascaded Multilevel Inverter
12
作者 M. Sudhakaran R. Seyezhai 《Circuits and Systems》 2016年第9期2633-2650,共18页
In cascaded H-bridge multilevel inverter, a variable frequency inverted sine PWM technique is modeled for hybrid electric vehicles. It has a particular advantage of increasing power which is achieved using series conn... In cascaded H-bridge multilevel inverter, a variable frequency inverted sine PWM technique is modeled for hybrid electric vehicles. It has a particular advantage of increasing power which is achieved using series connection of H-bridge and also this topology is capable to produce superior spectral quality with considerable improvement of fundamental voltage. The variable frequency inverted sine PWM technique produces lesser torque ripple and enhances the fundamental output voltage mainly at lower modulation index ranges. The topologies of multilevel inverter are flying capacitor, diode clamped and cascaded inverter. In the paper, we will discuss about the cascaded multilevel inverter based on inverted sine PWM technique. The two switching strategies widely used to control multilevel inverters are constant frequency inverted sine PWM (CF-ISPWM) and variable frequency inverted sine PWM (VF-ISPWM). This implies that switch utilization substantially reduces 32.35% of the constant frequency inverted sine PWM switching technique. The performance of the technique is validated in terms of Total Harmonic Distortion (THD) and Torque ripple which significantly reduces when compared to constant frequency ISPWM. The analysis of conventional triangular PWM inverter and inverted sine PWM inverter using constant and variable switching scheme is done in MATLAB Simulink and verified experimentally by FPGA Spartan 3E processor. 展开更多
关键词 Cascaded Multilevel inverter Constant frequency inverted Sine PWM Variable frequency inverted Sine PWM Total Harmonic Distortion
下载PDF
Finite Set-Model Predictive Current Control of Three-Phase Voltage Source Inverter for RES (Renewable Energy Systems) Applications
13
作者 Ali Almaktoof Atanda Raji Tariq Kahn 《Journal of Energy and Power Engineering》 2014年第4期749-756,共8页
This paper focuses on a combination of three-phase VSI (voltage source inverter) with a predictive current control to provide an optimized system for three-phase inverters that control the load current. A FS-MPC (f... This paper focuses on a combination of three-phase VSI (voltage source inverter) with a predictive current control to provide an optimized system for three-phase inverters that control the load current. A FS-MPC (finite set-model predictive control) strategy for a three-phase VSI for RES (renewable energy systems) applications is implemented. The renewable energy systems model is used in this paper to investigate the system performance when power is supplied to resistive-inductive load. With three different cases, the evaluation of the system is done. Firstly, the robustness of control strategy under variable DC-Link is done in terms of the THD (total harmonic distortion). Secondly, with one prediction step, the system performance is tested using different sampling time, and lastly, the dynamic response of the system with step change in the amplitude of the reference is investigated. The simulations and result analyses are carried out using Matlab/Simulink to test the effectiveness and robustness of FS-MPC for two-level VSI with AC filter for resistive-inductive load supplied by a renewable energy system. 展开更多
关键词 Finite set-model predictive control three-phase voltage source inverter renewable energy system application AC filter Matlab/Simulink.
下载PDF
Watermarking Images in the Frequency Domain by Exploiting Self-Inverting Permutations
14
作者 Maria Chroni Angelos Fylakis Stavros D. Nikolopoulos 《Journal of Information Security》 2013年第2期80-91,共12页
In this work we propose efficient codec algorithms for watermarking images that are intended for uploading on the web under intellectual property protection. Headed to this direction, we recently suggested a way in wh... In this work we propose efficient codec algorithms for watermarking images that are intended for uploading on the web under intellectual property protection. Headed to this direction, we recently suggested a way in which an integer number w which being transformed into a self-inverting permutation, can be represented in a two dimensional (2D) object and thus, since images are 2D structures, we have proposed a watermarking algorithm that embeds marks on them using the 2D representation of w in the spatial domain. Based on the idea behind this technique, we now expand the usage of this concept by marking the image in the frequency domain. In particular, we propose a watermarking technique that also uses the 2D representation of self-inverting permutations and utilizes marking at specific areas thanks to partial modifications of the image’s Discrete Fourier Transform (DFT). Those modifications are made on the magnitude of specific frequency bands and they are the least possible additive information ensuring robustness and imperceptiveness. We have experimentally evaluated our algorithms using various images of different characteristics under JPEG compression. The experimental results show an improvement in comparison to the previously obtained results and they also depict the validity of our proposed codec algorithms. 展开更多
关键词 WATERMARKING Techniques Image WATERMARKING Algorithms Self-inverting PERMUTATIONS 2D REPRESENTATIONS of PERMUTATIONS ENCODING DECODING frequency Domain Experimental Evaluation
下载PDF
RELIABLE HYSTERESIS CURRENT CONTROLLED DUAL BUCK HALF BRIDGE INVERTER 被引量:6
15
作者 刘军 严仰光 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2003年第1期67-72,共6页
A highly efficient and re liable topology-dual buck half bridge inverter (DBI) is introduced. The existenc e of discontinuous conduction mode (DCM) operation state requires the bias of in du ctor current for DBI imple... A highly efficient and re liable topology-dual buck half bridge inverter (DBI) is introduced. The existenc e of discontinuous conduction mode (DCM) operation state requires the bias of in du ctor current for DBI implemented with linear controllers like ramp comparison SP WM (RCSPWM) controllers. A novel operation scheme for DBI and a hysteresis curre nt controlled dual buck half bridge inverter (HCDBI) are proposed. The bias curr ent required by RCSPWM DBI is eliminated and conduction losses are dramatically reduced. HCDBI has greatly improved the modulation performance in DCM region for the benefit of its excellent command tracking capability. The operational schem e and control strategy are presented. Power losses of the conventional half brid ge inverter (CHBI) and HCDBI are compared with mathematical computation, and exp erimental verification is also executed. Both calculational and experimental res ults verify that HCDBI has a superior switching performance over CHBI. Its exce llent high frequency operational capacity provides another access to realize high fre quency operation of inverters. 展开更多
关键词 high frequency switch ing inverterS hysteresis current control half bridge
下载PDF
IMPROVEMENT IN WAVEFORM OF SWITCHING POINT-PRESET SPWM INVERTERS
16
作者 谢少军 裘卫红 严仰光 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 1995年第1期72-79,共8页
Total harmonic distortion (THD) is one of the key technical indexes of inverter output voltage. Optimization o f switching points and filter parameters could ensure the switching-point-preset sinusoidal pulse width mo... Total harmonic distortion (THD) is one of the key technical indexes of inverter output voltage. Optimization o f switching points and filter parameters could ensure the switching-point-preset sinusoidal pulse width modulation (SPWM) inverters with low harmonyic content in theory.The THD value would be increased by switching time delay of power devices and control circuit. A new control coecuit with delay time compensation is presented in this paper. With this control scheme, the output of the inverter could be basically identified with the theory given.Test results of experimental circuit verify that the control circuit presented in this paper is feasible. The THD of the inverter output voltage could be reduced to a certain extent by this method. 展开更多
关键词 inverterS pulse width modulation variable speed constant frequency (VSCF) total harmonic distortion switching-point-preset
下载PDF
Virtual Synchronous Generator: A Control Strategy to Improve Dynamic Frequency Control in Autonomous Power Systems 被引量:17
17
作者 Miguel Torres Luiz A. C. Lopes 《Energy and Power Engineering》 2013年第2期32-38,共7页
Ideally, diesel hybrid autonomous power systems would operate with high penetration of renewable energy sources such as wind and photovoltaic to minimize fuel consumption. However, since these are inherently intermitt... Ideally, diesel hybrid autonomous power systems would operate with high penetration of renewable energy sources such as wind and photovoltaic to minimize fuel consumption. However, since these are inherently intermittent and fluctuating, the grid-forming diesel engine generator sets are usually required to operate with larger amounts of spinning reserve, often at low loading conditions what tends to increases operating and maintenance costs. Frequency stability is of great concern in “small” systems, such as mini-grids, where any individual generator in-feed represents a substantial portion of the total demand. There, the initial rate of change of frequency is typically larger and a lower value of frequency can be reached in a shorter time than in conventional systems with all generation supplied by rotating machines, possibly resulting in under-frequency load shedding and tripping of renewable energy generators. The first part of this paper, discusses some general concepts regarding frequency stability in a diesel hybrid mini-grid and how energy storage systems can be used to enhance system performance. Then, a particular technique based on a virtual synchronous generator is presented and its effectiveness is demonstrated with simulation results. 展开更多
关键词 frequency Control Mini-Grid Energy STORAGE inverter
下载PDF
Topological Comparison and Analysis of Medium-voltage and High-power Direct-linked PV Inverter 被引量:15
18
作者 Xing Zhang Mingda Wang +3 位作者 Tao Zhao Wang Mao Yuhua Hu Renxian Cao 《CES Transactions on Electrical Machines and Systems》 CSCD 2019年第4期327-334,共8页
Among all the renewable energy sources,the installed capacity of solar power generation is the fastest growing in recent years,so photovoltaic(PV)power generation still has great market potential.Compared with low-pow... Among all the renewable energy sources,the installed capacity of solar power generation is the fastest growing in recent years,so photovoltaic(PV)power generation still has great market potential.Compared with low-power systems,large-scale PV systems are more commercially attractive,because they can reduce the cost of the system per watt.The PV inverters with centralized and string structure have been applied in large-scale PV plant,but it is difficult to further increase the voltage and power levels for a single converter.In addition,the line-frequency isolation transformer requires a large amount of materials and has a large volume and weight.Therefore,it is a current trend for large-scale PV system to increase the voltage and power levels to directly connect to the medium-voltage power grid.Based on this,this paper investigates and compares several topologies of PV inverters without line-frequency transformer,including the MMC structure and the three-phase cascaded H-bridge(CHB)structure,which are able to directly connect to the 35kV medium-voltage power grid,and can not only make the voltage and power levels higher,but also further reduce the cost and volume of the whole system. 展开更多
关键词 Direct-linked PV inverter large-scale PV system MMC structure three-phase CHB structure.
下载PDF
Multilevel Feature Moving Average Ratio Method for Fault Diagnosis of the Microgrid Inverter Switch 被引量:4
19
作者 Zhanjun Huang Zhanshan Wang Huaguang Zhang 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2017年第2期177-185,共9页
Multilevel feature moving average ratio method is proposed to realize an open-switch fault diagnosis for any switch of the microgrid inverter. The main steps of the proposed method include multilevel signal decomposit... Multilevel feature moving average ratio method is proposed to realize an open-switch fault diagnosis for any switch of the microgrid inverter. The main steps of the proposed method include multilevel signal decomposition, coefficient reconstruction, absolute average ratio process and artificial neural network U+0028 ANN U+0029 classification. Specifically, multilevel signal decomposition is realized by using the means of multi resolution analysis to obtain the different frequency band coefficients of the three-phase current signal. The related coefficient reconstruction is executed to achieve signals decomposition in different levels. Furthermore, according to the obtained data, the absolute average ratio process is used to extract absolute moving average ratio of signal decomposition in different levels for the three-phase current. Finally, to intelligently classify the inverter switch fault and realize the adaptive ability, the ANN technology is applied. Compared to conventional fault diagnosis methods, the proposed method can accurately detect and locate the open-switch fault for any location of the microgrid inverter. Additionally, it need not set related threshold of algorithm and does not require normalization process, which is relatively easy to implement. The effectiveness of the proposed fault diagnosis method is demonstrated through detailed simulation results. © 2017 Chinese Association of Automation. 展开更多
关键词 Deep neural networks Electric inverters Failure analysis frequency bands Neural networks Signal distortion Signal processing
下载PDF
Cascaded Multilevel Inverter Based Power and Signal Multiplex Transmission for Electric Vehicles 被引量:6
20
作者 Yixuan Zhang Guipeng Chen +2 位作者 Yihua Hu Chao Gong Yangang Wang 《CES Transactions on Electrical Machines and Systems》 CSCD 2020年第2期123-129,共7页
Power&signal multiplex transmission(P&SMT)is a technique that uses power electronic circuits for communication signal transmission.In this paper,a three-phase cascaded multilevel inverter-based P&S MT syst... Power&signal multiplex transmission(P&SMT)is a technique that uses power electronic circuits for communication signal transmission.In this paper,a three-phase cascaded multilevel inverter-based P&S MT system is proposed.The proposed method can transmit communication signals without using a Controller Area Network bus,thereby reducing the wiring cost of the conventional electric vehicle(EV)communication system.The designed system can achieve motor speed regulation and battery balance discharging for EVs.With the combined pulse width modulation scheme and frequency shift keying method,both power and communication signals are transmitted successfully in a simulation model implemented in Matlab/Simulink.By evaluating the bit error rate of the transmitted signal,the maximum signal rate of the proposed system is determined as 600 bit/s. 展开更多
关键词 Battery state of charge controller area network frequency shift keying motor speed control pulse width modulation three-phase DC-AC converter
下载PDF
上一页 1 2 103 下一页 到第