期刊文献+
共找到1,622篇文章
< 1 2 82 >
每页显示 20 50 100
Control strategy of LCL-type three-phase photovoltaic grid connected inverter 被引量:2
1
作者 WANG Si-hua WANG Jin-qiang 《Journal of Measurement Science and Instrumentation》 CAS CSCD 2019年第3期254-265,共12页
The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control str... The grid-connected inverter with LCL filter has the ability of easily attenuating high-frequency current harmonics. However, its suppression effect on the background harmonics in grid voltage is limited. A control strategy is presented, which is composed of an inner loop of capacitor current feedforward, an outer loop of grid-current feedforward and feedforward of grid voltage. The limitations and steps of parameters design for LCL filter are analyzed. Meanwhile, the capacitor current loop is employed to damp the resonant peak caused by the LCL filter and enhance the stability. The properties of different controllers are analyzed and compared, thereinto quasi-proportional-rasonant (PR) controller realizes the control with zero steady-state error of AC variables in static coordinates. In order to suppress the current distortion effected by the background harmonics in grid voltage, the feed-forward function is calculated for the grid-connected inverter with an LCL filter. After simplifying the block diagram, a full-feedforward control strategy for grid voltage is proposed. Theoretical analysis and Matlab/Simulink simulation results show that the proposed method has the advantages of high steady accuracy, fast dynamic response and strong robustness. 展开更多
关键词 three-phase grid-connected inverter LCL filter active damping quasi-proportional-resonant (PR) control full-feedforward of grid voltages
下载PDF
A novel cascaded H-bridge photovoltaic inverter with flexible arc suppression function
2
作者 Junyi Tang Wei Gao 《Global Energy Interconnection》 EI CSCD 2024年第4期513-527,共15页
This paper presents a novel approach that simultaneously enables photovoltaic(PV)inversion and flexible arc suppression during single-phase grounding faults.Inverters compensate for ground currents through an arc-elim... This paper presents a novel approach that simultaneously enables photovoltaic(PV)inversion and flexible arc suppression during single-phase grounding faults.Inverters compensate for ground currents through an arc-elimination function,while outputting a PV direct current(DC)power supply.This method effectively reduces the residual grounding current.To reduce the dependence of the arc-suppression performance on accurate compensation current-injection models,an adaptive fuzzy neural network imitating a sliding mode controller was designed.An online adaptive adjustment law for network parameters was developed,based on the Lyapunov stability theorem,to improve the robustness of the inverter to fault and connection locations.Furthermore,a new arc-suppression control exit strategy is proposed to allow a zerosequence voltage amplitude to quickly and smoothly track a target value by controlling the nonlinear decrease in current and reducing the regulation time.Simulation results showed that the proposed method can effectively achieve fast arc suppression and reduce the fault impact current in single-phase grounding faults.Compared to other methods,the proposed method can generate a lower residual grounding current and maintain good arc-suppression performance under different transition resistances and fault locations. 展开更多
关键词 photovoltaic inverter Flexible arc suppression Adaptive control Fuzzy neural network Sliding mode control Exit strategy
下载PDF
Adaptive Predefined-Time Backstepping Control for Grid Connected Photovoltaic Inverter
3
作者 Jiarui Zhang Dan Liu +4 位作者 Kan Cao Ping Xiong Xiaotong Ji Yanze Xu Yunfei Mu 《Energy Engineering》 EI 2024年第8期2065-2083,共19页
The system performance of grid-connected photovoltaic(PV)has a serious impact on the grid stability.To improve the control performance and shorten the convergence time,a predefined-time controller based on backsteppin... The system performance of grid-connected photovoltaic(PV)has a serious impact on the grid stability.To improve the control performance and shorten the convergence time,a predefined-time controller based on backstepping technology and dynamic surface control is formulated for the inverter in the grid-connected photovoltaic.The time-varying tuning functions are introduced into state-tracking errors to realize the predefined-time control effect.To address the“computational explosion problem”in the design process of backstepping control,dynamic surface control is adopted to avoid the analytical calculations of virtual control.The disturbances of the PV system are estimated and compensated by adaptive laws.The control parameters are chosen and the global stability of the closed-loop is ensured by Lyapunov conditions.Simulation results confirm the effectiveness of the proposed controller and ensure the predefined time control in the photovoltaic inverter. 展开更多
关键词 photovoltaic inverter system backstepping technology predefined-time control adaptive control
下载PDF
Integration of a Fault-Tolerant H-Bridge Inverter into the Photovoltaic System for DC-AC Conversion of Electrical Energy
4
作者 Dobsoumna Emmanuel Djondiné Philippe +2 位作者 Issa Dieudonné Douniya Edouard Ronwé Djorwé Frédéric 《Journal of Energy and Power Engineering》 CAS 2024年第3期93-103,共11页
The photovoltaic system is experiencing great growth in the production of electrical energy these days.It plays a vital role in the production of electrical energy in isolated towns.It is generally either stand-alone ... The photovoltaic system is experiencing great growth in the production of electrical energy these days.It plays a vital role in the production of electrical energy in isolated towns.It is generally either stand-alone or connected to a network.The energy produced by the photovoltaic generator is in continuous form;the conversion from its continuous form to the alternating form requires a converter:the inverter.In order to improve the quality of the waveform,we moved from the classic solar inverter to multilevel inverters.These multilevel inverters are equipped with power switches which are required to withstand strong fluctuations in the voltage produced by the GPV(photovoltaic generator).It is obvious that the degradation of the inverter leads to a distortion of the wave quality.This article presents the simulation of the GPV-Chopper Boost-Inverter chain in fault-tolerant cascaded H-bridges in order to overcome the difficulties of voltage constraints experienced by power switches(IGBT:insulated gate bipolar transistor).The results of simulations carried out in Matlab/Simulink show good performance of the designed inverter model. 展开更多
关键词 photovoltaic generator boost chopper FAULT-TOLERANT H-bridge inverter GPV-chopper
下载PDF
Reducing Condensation Inside the Photovoltaic(PV)Inverter according to the Effect of Diffusion as a Process of Vapor Transport
5
作者 Amal El Berry Marwa M.Ibrahim +1 位作者 A.A.Elfeky Mohamed F.Nasr 《Frontiers in Heat and Mass Transfer》 EI 2024年第4期1189-1207,共19页
A photovoltaic(PV)inverter is a vital component of a photovoltaic(PV)solar system.Photovoltaic(PV)inverter failure can mean a solar system that is no longer functioning.When electronic devices such as photovoltaic(PV)... A photovoltaic(PV)inverter is a vital component of a photovoltaic(PV)solar system.Photovoltaic(PV)inverter failure can mean a solar system that is no longer functioning.When electronic devices such as photovoltaic(PV)inverter devices are subjected to vapor condensation,a risk could occur.Given the amount of moisture in the air,saturation occurswhen the temperature drops to the dewpoint,and condensationmay formon surfaces.Numerical simulation with“COMSOL Software”is important for obtaining knowledge relevant to preventing condensation by using two steps.At first,the assumption was that the device’s water vapor concentration was homogeneous to evaluate the amount of liquid water accumulated on the internal walls of the photovoltaic(PV)inverter box.Second,by considering the effect of external wind velocity onmoisture transport at the air interface to evaluate water vapor transport outdoors and reduce condensation.General factorial designs are utilized for analyzing the nature of the relationship between the vapor condensation response and the variables.Reducing vapor condensation inside the solar inverter by the effect of external wind speed on diffusion as a process of transporting moister air outside the inverter box is the main solution for this problem.During the movement and assessment of the flow of water vapor,the impact of vapor condensation is reduced.The saturation period was determined by using a Boolean saturation indicator.The saturation indicator was set to 1 when saturation was detected(relative humidity greater than or equal to 1)and 0 otherwise.Calculating the flow and dispersion of moist air as a function of wind speed helped solve the problem. 展开更多
关键词 photovoltaic inverter failure vapor condensation wind velocity diffusion transport and general factorial
下载PDF
THREE-PHASE BRIDGE INVERTER FOR 9kW DOUBLY SALIENT PERMANENT MAGNET MOTOR
6
作者 黄伟君 秦海鸿 +1 位作者 王慧贞 严仰光 《Transactions of Nanjing University of Aeronautics and Astronautics》 EI 2006年第1期27-33,共7页
The three-phase bridge inverter is used as the converter topology in the power controller for a 9 kW doubly salient permanent magnet (DSPM) motor. Compared with common three-phase bridge inverters, the proposed inve... The three-phase bridge inverter is used as the converter topology in the power controller for a 9 kW doubly salient permanent magnet (DSPM) motor. Compared with common three-phase bridge inverters, the proposed inverter works under more complicated conditions with different principles for special winding back EMFs, position signals of hall sensors, and the given mode of switches. The ideal steady driving principles of the inverter for the motor are given. The working state with asymmetric winding back EMFs, inaccurate position signals of hall sensors, and the changing input voltage is analyzed. Finally, experimental results vertify that the given anal ysis is correct. 展开更多
关键词 doubly salient permanent magnet motor three-phase bridge inverter winding back EMF position signal of hall sensor input voltage
下载PDF
A new three-phase 5-level current-source inverter 被引量:4
7
作者 BAO Jian-yu BAI Zhi-hong +1 位作者 WANG Qing-song ZHANG Zhong-chao 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2006年第12期1973-1978,共6页
The new three-phase 5-level current-source inverter (CSI) proposed in this paper was developed by connecting three separate single-phase 5-level CSIs in series, and its operational principle was analyzed. There are tw... The new three-phase 5-level current-source inverter (CSI) proposed in this paper was developed by connecting three separate single-phase 5-level CSIs in series, and its operational principle was analyzed. There are two major problems existing in current-source multilevel inverters, one is the complex PWM control method (2-logic to 3-logic conversion), and the other is the problem of current-unbalance between different levels. A simple current-balance control method via DC current feedback is applied in each single-phase 5-level CSI cell to implement the current-balance control between different levels. And to reduce the output current harmonics, POD PWM control technique was used. Simulation and experimental results showed that this new three-phase 5-level CSI topology operates correctly. 展开更多
关键词 three-phase Current-source inverter (CSI) 5-level HARMONICS POD PWM
下载PDF
A Review of Novel Leakage Current Suppression Techniques for Transformerless Photovoltaic Inverters 被引量:32
8
作者 WU Weiyang GUO Xiaoqiang 《中国电机工程学报》 EI CSCD 北大核心 2012年第18期I0001-I0022,170,共22页
漏电流抑制是无变压器型光伏并网系统需要解决的关键问题之一。VDE-0126-1-1标准规定,漏电流高于300 mA时光伏并网系统必须在0.3 s内从电网中切除。为了解释漏电流的根源,建立系统共模电压数学模型,在此基础上分析漏电流产生的原因,探... 漏电流抑制是无变压器型光伏并网系统需要解决的关键问题之一。VDE-0126-1-1标准规定,漏电流高于300 mA时光伏并网系统必须在0.3 s内从电网中切除。为了解释漏电流的根源,建立系统共模电压数学模型,在此基础上分析漏电流产生的原因,探讨不同调制策略对漏电流的影响,然后介绍几种典型的、能够有效抑制漏电流的电路拓扑结构,并分析各种拓扑的工作原理和特点。最后对漏电流抑制技术方面的发展趋势做了展望。 展开更多
关键词 新型变压器 光伏系统 漏电流 逆变器 技术 综述 低成本 电网
下载PDF
An Efficient Fuzzy Logic Fault Detection and Identification Method of Photovoltaic Inverters 被引量:1
9
作者 Mokhtar Aly Hegazy Rezk 《Computers, Materials & Continua》 SCIE EI 2021年第5期2283-2299,共17页
Fuzzy logic control(FLC)systems have found wide utilization in several industrial applications.This paper proposes a fuzzy logic-based fault detection and identification method for open-circuit switch fault in grid-ti... Fuzzy logic control(FLC)systems have found wide utilization in several industrial applications.This paper proposes a fuzzy logic-based fault detection and identification method for open-circuit switch fault in grid-tied photovoltaic(PV)inverters.Large installations and ambitious plans have been recently achieved for PV systems as clean and renewable power generation sources due to their improved environmental impacts and availability everywhere.Power converters represent the main parts for the grid integration of PV systems.However,PV power converters contain several power switches that construct their circuits.The power switches in PV systems are highly subjected to high stresses due to the continuously varying operating conditions.Moreover,the grid-tied systems represent nonlinear systems and the system model parameters are changing continuously.Consequently,the grid-tied PV systems have a nonlinear factor and the fault detection and identification(FDI)methods based on using mathematical models become more complex.The proposed fuzzy logic-based FDI(FL-FDI)method is based on employing the fuzzy logic concept for detecting and identifying the location of various switch faults.The proposed FL-FDI method is designed and extracted from the analysis and comparison of the various measured voltage/current components for the control purposes.Therefore,the proposed FL-FDI method does not require additional components or measurement circuits.Additionally,the proposed method can detect the faulty condition and also identify the location of the faulty switch for replacement and maintenance purposes.The proposed method can detect the faulty condition within only a single fundamental line period without the need for additional sensors and/or performing complex calculations or precise models.The proposed FL-FDI method is tested on the widely used T-type PV inverter system,wherein there are twelve different switches and the FDI process represents a challenging task.The results shows the superior and accurate performance of the proposed FL-FDI method. 展开更多
关键词 Fault detection and identification fuzzy logic T-type inverter photovoltaic(PV)
下载PDF
The Research of Three-phase Boost/Buck-boost DC-AC Inverter
10
作者 Xiangli Li Zhaoyang Yan +1 位作者 Yanni Gao Hanhong Qi 《Energy and Power Engineering》 2013年第4期906-913,共8页
This paper presents a new inverter based on three-phase Boost/Buck-boost single-stage inverter. The basic configuration of the new topology and their fundamental principle are firstly introduced, the method of design ... This paper presents a new inverter based on three-phase Boost/Buck-boost single-stage inverter. The basic configuration of the new topology and their fundamental principle are firstly introduced, the method of design double-loop controller and sliding mode controller are clarified, analyzed and compared in the following. Finally the validity and feasibility of the new topology are tested by simulation. The results indicate that regulation of the voltage transfer ratio and output frequency can be realized optionally by the new converter, furthermore the harmonic distortion of waveform is low. So the inherent drawback of low voltage transfer ratio of traditional converter is effectively settled. This study may provide inspiration for further engineering application. 展开更多
关键词 three-phase BOOST SINGLE-STAGE inverter three-phase BUCK-BOOST SINGLE-STAGE inverter Double-loop CONTROLLER Sliding Mode CONTROLLER
下载PDF
The Control Technology Research of the Z-source Three-phase Four-bridge Arm Inverter
11
作者 Xiangli Li Zhaoyang Yan +2 位作者 Keke Pan Chenghao Ma Hanhong Qi 《Energy and Power Engineering》 2013年第4期733-739,共7页
Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth le... Z-source inverter can boost the voltage of the DC-side, allow the two switches of the same bridge arm conducting at the same time and it has some other advantages. The zero-sequence current flows through the fourth leg of the three-phase four-leg inverter so the three-phase four-leg inverter can work with unbalanced load. This paper presents a Z-source three-phase four-leg inverter which combines a Z-source network with three-phase four-leg inverter. The circuit uses simple SPWM modulation technique and the fourth bridge arm uses fully compensated control method. The inverter can maintain a symmetrical output voltage when the proposed scheme under the unbalanced load. 展开更多
关键词 Z-SOURCE inverter three-phase FOUR-LEG inverter Unbalanced Load Imbalanced VOLTAGE
下载PDF
Comparison between SiC- and Si-Based Inverters for Photovoltaic Power Generation Systems
12
作者 Yuji Ando Yasuhiro Shirahata +6 位作者 Takeo Oku Taisuke Matsumoto Yuya Ohishi Masashi Yasuda Akio Shimono Yoshikazu Takeda Mikio Murozono 《Journal of Power and Energy Engineering》 2017年第1期30-40,共11页
100-W class power storage systems were developed, which comprised spherical Si solar cells, a maximum power point tracking charge control-ler, a lithium-ion battery, and one of two different types of direct current (D... 100-W class power storage systems were developed, which comprised spherical Si solar cells, a maximum power point tracking charge control-ler, a lithium-ion battery, and one of two different types of direct current (DC)-alter- nating current (AC) converters. One inverter used SiC met-al-oxide-semicon-ductor field-effect transistors (MOSFETs) as switching devices while the other used Si MOSFETs. In these 100-W class inverters, the ON resistance was considered to have little influence on the efficiency. Nevertheless, the SiC-based inverter exhibited an approximately 3% higher DC-AC conversion efficiency than the Si-based inverter. Power loss analysis indicated that the higher efficiency resulted predominantly from lower switching and reverse recovery losses in the SiC MOSFETs compared with in the Si MOSFETs. 展开更多
关键词 Silicon CARBIDE Solar Cell inverter photovoltaic Device MAXIMUM Power Point Tracking LITHIUM-ION Battery
下载PDF
The improved PAC method for a three-phase PWM grid-connected inverter
13
作者 李杰 马祎炜 +2 位作者 陈国呈 王得利 俞俊杰 《Journal of Shanghai University(English Edition)》 CAS 2008年第6期560-564,共5页
In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response w... In this paper, a vector regulating principle of the phase and amplitude control PAC method for three-phase grid-connected inverters is presented.To solve the problem of heavy inrush current and slow dynamic response when system starts up, the starting voltage prediction control and the current feed-forward control are proposed and used, which improve the dynamic performance of the system in the PAC.The experimental results carried out on a three-phase grid-connected inverter proved the validity of the proposed method. 展开更多
关键词 three-phase pulse width modulation (PWM) grid-connected inverter phase and amplitude control (PAC) starting voltage prediction control current feed-forward control
下载PDF
Performance Assessment of Islanding Detection for Mul-ti-inverter Grid-connected Photovoltaic Systems
14
作者 Xing Zhang Dong Xie 《Energy and Power Engineering》 2013年第4期1517-1520,共4页
Islanding detection is an essential function for safety and reliability in grid-connected Distributed Generation Systems (DGS). Passive and active islanding detection methods have been analyzed in literature consideri... Islanding detection is an essential function for safety and reliability in grid-connected Distributed Generation Systems (DGS). Passive and active islanding detection methods have been analyzed in literature considering DGS with only one inverter connected to the utility. With the big scale application of photovoltaic (PV) power systems, islanding detection technology of multi-inverter DGS has been paid more attention. This paper analyzes the performance of diverse islanding detection methods in multiple inverters grid-connected PV systems. Non-Detection Zones (NDZ) of multi-inverter systems in a load parameter space are used as analytical tool. The paper provides guidance for the islanding detection design in multiple grid-connected inverters. 展开更多
关键词 photovoltaic Power Systems ISLANDING DETECTION Multi-inverter Non-Detection ZONES
下载PDF
A Study of DTC-Power Electronic Cascade Fed by Photovoltaic Cell-Three-Level NPC Inverter
15
作者 Iqbal Messaif El-Madjid Berkouk Nadia Saadia 《Smart Grid and Renewable Energy》 2010年第3期109-118,共10页
This paper proposes a high performance three-level inverter Neutral Point Clamped (NPC) structure for photovoltaic system. The proposed configuration which can boost the low voltage of photovoltaic (PV) array, can als... This paper proposes a high performance three-level inverter Neutral Point Clamped (NPC) structure for photovoltaic system. The proposed configuration which can boost the low voltage of photovoltaic (PV) array, can also convert the photovoltaic DC power into high quality AC power. Attention has been paid to the problem of neutral point potential variation. In this way, a Direct Torque Control (DTC) technique has been applied and the estimated value of the Neutral Point Potential (NPP) is used, which is calculated by motor currents. This control strategy uses the redundancy presented by the inverter for selecting appropriate switching state through a switching table to achieve the control of NPP. This study shows the effect of the stability problem of the DC voltages and good static and dynamic performances were obtained in simulation of the proposed cascade “photovoltaic cell-three-level NPC VSI-induction motor”. 展开更多
关键词 DTC Switching Table NPC Three-Level inverter photovoltaic Neutral Point Potential Redundant States
下载PDF
Modular Multilevel Inverter with Maximum Power Point Tracking for Grid Connected Photovoltaic Application
16
作者 Bader Naser Alajmi Khaled Hani Ahmed +2 位作者 Grain Philip Adam Stephen Jon Finney Barry WayneWilliams 《Journal of Energy and Power Engineering》 2012年第10期1680-1687,共8页
A single-phase modular multilevel inverter based photovoltaic system for grid connection is proposed. This photovoltaic system utilizes two conversion stages: a boost converter for tracking the maximum power point an... A single-phase modular multilevel inverter based photovoltaic system for grid connection is proposed. This photovoltaic system utilizes two conversion stages: a boost converter for tracking the maximum power point and a modular multilevel inverter used as an interfacing unit. The maximum power point tracking is achieved with a fuzzy logic controller, and the modular multilevel inverter regulates the DC link voltage and synchronizes the grid voltage and current in order to achieve unity power factor operation. The proposed system provides high dynamic performance and power quality injected into the grid. The validity of the proposed system is confirmed by simulations. 展开更多
关键词 photovoltaic boost converter multilevel inverter maximum power point tracker.
下载PDF
Finite Set-Model Predictive Current Control of Three-Phase Voltage Source Inverter for RES (Renewable Energy Systems) Applications
17
作者 Ali Almaktoof Atanda Raji Tariq Kahn 《Journal of Energy and Power Engineering》 2014年第4期749-756,共8页
This paper focuses on a combination of three-phase VSI (voltage source inverter) with a predictive current control to provide an optimized system for three-phase inverters that control the load current. A FS-MPC (f... This paper focuses on a combination of three-phase VSI (voltage source inverter) with a predictive current control to provide an optimized system for three-phase inverters that control the load current. A FS-MPC (finite set-model predictive control) strategy for a three-phase VSI for RES (renewable energy systems) applications is implemented. The renewable energy systems model is used in this paper to investigate the system performance when power is supplied to resistive-inductive load. With three different cases, the evaluation of the system is done. Firstly, the robustness of control strategy under variable DC-Link is done in terms of the THD (total harmonic distortion). Secondly, with one prediction step, the system performance is tested using different sampling time, and lastly, the dynamic response of the system with step change in the amplitude of the reference is investigated. The simulations and result analyses are carried out using Matlab/Simulink to test the effectiveness and robustness of FS-MPC for two-level VSI with AC filter for resistive-inductive load supplied by a renewable energy system. 展开更多
关键词 Finite set-model predictive control three-phase voltage source inverter renewable energy system application AC filter Matlab/Simulink.
下载PDF
New Approach of Multi-Cell Stacked Cell Inverter for Solar Photovoltaic System
18
作者 François Yonga Colince Welba +1 位作者 Abdouramani Dadjé Noël Djongyang 《Journal of Power and Energy Engineering》 2023年第1期1-17,共17页
In this paper, a new inverter topology dedicated to isolated or grid-connected PV systems is proposed. This inverter is based on the structures of a stacked multi-cell converter (SMC) and an H-bridge. This new topolog... In this paper, a new inverter topology dedicated to isolated or grid-connected PV systems is proposed. This inverter is based on the structures of a stacked multi-cell converter (SMC) and an H-bridge. This new topology has allowed the voltage stresses of the converter to be distributed among several switching cells. Secondly, divide the input voltage into several fractions to reduce the number of power semiconductors to be switched. In this contribution, the general topology of this micro-inverter has been described and the simulation tests developed to validate its operation have been presented. Finally, we discussed the simulation results, the efficiency of this topology and the feasibility of its use in a grid-connected photovoltaic production system. 展开更多
关键词 photovoltaic System MICRO-inverter Stacked Multi-Cell Converter (SMC) H-BRIDGE Pulse Width Modulation (PWM)
下载PDF
Polymer Fiber Rigid Network with High Glass Transition Temperature Reinforces Stability of Organic Photovoltaics
19
作者 Qiao Zhou Cenqi Yan +18 位作者 Hongxiang Li Zhendong Zhu Yujie Gao Jie Xiong Hua Tang Can Zhu Hailin Yu Sandra P.Gonzalez Lopez Jiayu Wang Meng Qin Jianshu Li Longbo Luo Xiangyang Liu Jiaqiang Qin Shirong Lu Lei Meng Frédéric Laquai Yongfang Li Pei Cheng 《Nano-Micro Letters》 SCIE EI CAS CSCD 2024年第11期56-69,共14页
Organic photovoltaics(OPVs)need to overcome limitations such as insufficient thermal stability to be commercialized.The reported approaches to improve stability either rely on the development of new materials or on ta... Organic photovoltaics(OPVs)need to overcome limitations such as insufficient thermal stability to be commercialized.The reported approaches to improve stability either rely on the development of new materials or on tailoring the donor/acceptor morphology,however,exhibiting limited applicability.Therefore,it is timely to develop an easy method to enhance thermal stability without having to develop new donor/acceptor materials or donor–acceptor compatibilizers,or by introducing another third component.Herein,a unique approach is presented,based on constructing a polymer fiber rigid network with a high glass transition temperature(T_(g))to impede the movement of acceptor and donor molecules,to immobilize the active layer morphology,and thereby to improve thermal stability.A high-T_(g) one-dimensional aramid nanofiber(ANF)is utilized for network construction.Inverted OPVs with ANF network yield superior thermal stability compared to the ANF-free counterpart.The ANF network-incorporated active layer demonstrates significantly more stable morphology than the ANF-free counterpart,thereby leaving fundamental processes such as charge separation,transport,and collection,determining the device efficiency,largely unaltered.This strategy is also successfully applied to other photovoltaic systems.The strategy of incorporating a polymer fiber rigid network with high T_(g) offers a distinct perspective addressing the challenge of thermal instability with simplicity and universality. 展开更多
关键词 inverted organic photovoltaics Thermal stability Aramid nanofibers Morphology control Charge carrier dynamics
下载PDF
Model Predictive Control for Cascaded H-Bridge PV Inverter with Capacitor Voltage Balance
20
作者 Xinwei Wei Wanyu Tao +4 位作者 Xunbo Fu Xiufeng Hua Zhi Zhang Xiaodan Zhao Chen Qin 《Journal of Electronic Research and Application》 2024年第2期79-85,共7页
We designed an improved direct-current capacitor voltage balancing control model predictive control(MPC)for single-phase cascaded H-bridge multilevel photovoltaic(PV)inverters.Compared with conventional voltage balanc... We designed an improved direct-current capacitor voltage balancing control model predictive control(MPC)for single-phase cascaded H-bridge multilevel photovoltaic(PV)inverters.Compared with conventional voltage balanc-ing control methods,the method proposed could make the PV strings of each submodule operate at their maximum power point by independent capacitor voltage control.Besides,the predicted and reference value of the grid-connected current was obtained according to the maximum power output of the maximum power point tracking.A cost function was con-structed to achieve the high-precision grid-connected control of the CHB inverter.Finally,the effectiveness of the proposed control method was verified through a semi-physical simulation platform with three submodules. 展开更多
关键词 Model predictive control(MPC) photovoltaic system Cascaded H-bridge(CHB)inverter Capacitor voltage balance
下载PDF