Empirical mode decomposition using variable filtering with time scale calibrating 被引量:1
1
作者 Yuan Ye Mei Wenbo +1 位作者 Wu Siliang Yuan Qi 《Journal of Systems Engineering and Electronics》 SCIE EI CSCD 2008年第6期1076-1081,共6页
A novel and efficient method for decomposing a signal into a set of intrinsic mode functions (IMFs) and a trend is proposed. Unlike the original empirical mode decomposition (EMD), which uses spline fits to extrac... A novel and efficient method for decomposing a signal into a set of intrinsic mode functions (IMFs) and a trend is proposed. Unlike the original empirical mode decomposition (EMD), which uses spline fits to extract variations from the signal by separating the local mean from the fluctuations in the decomposing process, this new method being proposed takes advantage of the theory of variable finite impulse response (FIR) filtering where filter coefficients and breakpoint frequencies can be adjusted to track any peak-to-peak time scale changes. The IMFs are results of a multiple variable frequency response FIR filtering when signals pass through the filters. Numerical examples validate that in contrast with the original EMD, the proposed method can fine-tune the frequency resolution and suppress the aliasing effectively. 展开更多
关键词 empirical mode decomposition variable FIR filtering time scale calibrating.
下载PDF
The study of time calibration for upgraded end cap TOF of BESIII
2
作者 Ying-Xiao Guo Sheng-Sen Sun +9 位作者 Fen-Fen An Rong-Xing Yang Ming Zhou Zhi Wu Hong-Liang Dai Yue-Kun Heng Cheng Li Zi-Yan Deng Huai-Min Liu Wei-Guo Li 《Radiation Detection Technology and Methods》 2017年第2期51-56,共6页
Purpose The end cap time of flight at Beijing Spectrometer is upgraded with multi-gap resistive plate chamber technology in order to improve the charged particle identification capability.The time-over-threshold is us... Purpose The end cap time of flight at Beijing Spectrometer is upgraded with multi-gap resistive plate chamber technology in order to improve the charged particle identification capability.The time-over-threshold is used for the time slewing correction instead of the signal amplitude.Methods The correlation of the multi-peak time-over-threshold and the hit position along the strip of the charged particle is investigated.Implementation of the off-line data calibration method is discussed in detail.Results and conclusion The overall time resolution for pions with momentum around 0.8 GeV/c is about 65 ps. 展开更多
关键词 Time calibration Time of flight MRPC BESIII