BACKGROUND Supernumerary phantom limb(SPL)sensation is the experience of additional limbs,either single or a pair of limbs.Unique to traumatic spinal cord injuries,we report effect of transcranial direct current stimu...BACKGROUND Supernumerary phantom limb(SPL)sensation is the experience of additional limbs,either single or a pair of limbs.Unique to traumatic spinal cord injuries,we report effect of transcranial direct current stimulation(tDCS)on SPL pain in a patient with cervical cord injury.CASE SUMMARY The subject was a 57-year-old man who was diagnosed with complete spinal cord injury(C6/C5,motor level;C5/C5,sensory level;AIS-A)approximately three months ago.After a period of 2 wk,we administered anodal tDCS over the motor cortex for 15 minutes at an intensity of 1.5 mA.Following that treatment,the patient experienced a decrease of SPL pain intensity and frequency,which lasted for 1 week after the end of treatment.CONCLUSION Targeting the motor cortex through neuromodulation appears to be a promising option for the management of SPL pain.展开更多
Monte Carlo simulations are frequently utilized in radiation dose assessments.However,many researchers find the prevailing computing platforms to be intricate.This highlights a pressing need for a specialized framewor...Monte Carlo simulations are frequently utilized in radiation dose assessments.However,many researchers find the prevailing computing platforms to be intricate.This highlights a pressing need for a specialized framework for phantom dose evalua-tion.To address this gap,we developed a user-friendly radiation dose assessment platform using the Monte Carlo toolkit,Geant4.The Tsinghua University Phantom Dose(THUDosePD)augments the flexibility of Monte Carlo simulations in dosi-metric research.Originating from THUDose,a code with generic,functional,and application layers,THUDosePD focuses predominantly on anatomical phantom dose assessment.Additionally,it enables medical exposure simulation,intricate geometry creation,and supports both three-dimensional radiation dose analysis and phantom format transformations.The system operates on a multi-threaded parallel CPU architecture,with some modules enhanced for GPU parallel computing.Benchmark tests on the ICRP reference male illustrated the capabilities of THUDosePD in phantom dose assessment,covering the effective dose,three-dimensional dose distribution,and three-dimensional organ dose.We also conducted a voxelization conversion on the polygon mesh phantom,demonstrating the method’s efficiency and consistency.Extended applications based on THUDosePD further underline its broad adaptability.This intuitive,three-dimensional platform stands out as a valuable tool for phantom radiation dosimetry research.展开更多
Background:As mammography X-ray imaging technologies advance and provide elevated contrast in soft tissues,a need has developed for reliable imaging phantoms for use in system design and component calibration.In advan...Background:As mammography X-ray imaging technologies advance and provide elevated contrast in soft tissues,a need has developed for reliable imaging phantoms for use in system design and component calibration.In advanced imaging modalities such as refraction-based methods,it is critical that developed phantoms capture the biological details seen in clinical precancerous and cancerous cases while minimizing artifacts that may be caused due to phantom production.This work presents the fabrication of a breast tissue imaging phantom from cadaveric breast tissue suitable for use in both transmission and refraction-enhanced imaging systems.Methods:Human cancer cell tumors were grown orthotopically in nude athymic mice and implanted into the fixed tissue while maintaining the native tumor/adipose tissue interface.Results:The resulting human–murine tissue hybrid phantom was mounted on a clear acrylic housing for absorption and refraction X-ray imaging.Digital breast tomosynthesis was also performed.Conclusion:Both attenuation-based imaging and refraction-based imaging of the phantom are presented to confirm the suitability of this phantom's use in both imaging modalities.展开更多
Introduction: The ring vortex phantom is a novel, cost-effective prototype which generates complex and well-characterised reference flows in the form of the ring vortex. Although its reproducibility has been demonstra...Introduction: The ring vortex phantom is a novel, cost-effective prototype which generates complex and well-characterised reference flows in the form of the ring vortex. Although its reproducibility has been demonstrated, with ring speeds routinely behaving within 10% tolerances at speeds of approximately 10 - 70 cm/s, a form of real-time QA of the device at the time of imaging is needed to confirm correct function on demand in any environment. Methods: The technology described here achieves real-time QA, comprising a linear encoder, laser-photodiode array, and Doppler probe, measuring piston motion, ring speed and intra-ring velocity respectively. This instrumentation does not interfere with imaging system QA, but allows QA to be performed on both the ring vortex and the device in real-time. Results: The encoder reports the reliability of the piston velocity profile, whilst ring speed is measured by laser behaviour. Incorporation of a calibrated Doppler probe offers a consistency check that confirms behaviour of the central axial flow. For purposes of gold-standard measurement, all elements can be related to previous Laser PIV acquisitions with the same device settings. Conclusion: Consequently, ring vortex production within tolerances is confirmed by this instrumentation, delivering accurate QA in real-time. This implementation offers a phantom QA procedure that exceeds anything seen in the literature, providing the technology to enhance quantitative assessment of flow imaging modalities.展开更多
Successfully utilized non-axisymmetric endwalls to enhance turbine efficiencies(aerodynamic and turbine inlet temperatures)by controlling the characteristics of the secondary flow in a blade passage.This is accomplish...Successfully utilized non-axisymmetric endwalls to enhance turbine efficiencies(aerodynamic and turbine inlet temperatures)by controlling the characteristics of the secondary flow in a blade passage.This is accomplished by steady-state numerical hydrodynamics and deep knowledge of the field of flow.Because of the interaction between mainstream and purge flow contributing supplementary losses in the stage,non-axisymmetric endwalls are highly susceptible to the inception of purge flow exit compared to the flat and any advantage rapidly vanishes.The conclusions reveal that the supreme endwall pattern could yield a lowering of the gross pressure loss at the design stage and is related to the size of the top-loss location being productively lowered.This has led to diminished global thermal exchange lowered in the passage of the vane alone.The reverse flow adjacent to the suction side corner of the endwall is migrated farther from the vane surface,as the deviated pressure spread on the endwall accelerates the flow and progresses the reverse flow core still downstream.The depleted association between the tornado-like vortex and the corner vortex adjacent to the suction side corner of the endwall is the dominant mechanism of control in the contoured end wall.In this publication,we show that the non-axisymmetric endwall contouring by selective numerical shape change method at most prominent locations is advantageous in lowering the thermal load in turbines to augment the net heat flux reduction as well as the aerodynamic performance using multi-objective optimization.展开更多
文摘BACKGROUND Supernumerary phantom limb(SPL)sensation is the experience of additional limbs,either single or a pair of limbs.Unique to traumatic spinal cord injuries,we report effect of transcranial direct current stimulation(tDCS)on SPL pain in a patient with cervical cord injury.CASE SUMMARY The subject was a 57-year-old man who was diagnosed with complete spinal cord injury(C6/C5,motor level;C5/C5,sensory level;AIS-A)approximately three months ago.After a period of 2 wk,we administered anodal tDCS over the motor cortex for 15 minutes at an intensity of 1.5 mA.Following that treatment,the patient experienced a decrease of SPL pain intensity and frequency,which lasted for 1 week after the end of treatment.CONCLUSION Targeting the motor cortex through neuromodulation appears to be a promising option for the management of SPL pain.
基金This work was supported by the National Natural Science Foundation of China(General Program)(Nos.12175114,U2167209)the Foundation of Key Laboratory of Metrology and Calibration Technology(No.JLKG2022001C001)+2 种基金the Platform Development foundation of China Institute for Radiation Protection(No.YP21030101)the National Key R&D Program of China(No.2021YFF0603600)the Tsinghua University Initiative Scientific Research Program(No.20211080081).
文摘Monte Carlo simulations are frequently utilized in radiation dose assessments.However,many researchers find the prevailing computing platforms to be intricate.This highlights a pressing need for a specialized framework for phantom dose evalua-tion.To address this gap,we developed a user-friendly radiation dose assessment platform using the Monte Carlo toolkit,Geant4.The Tsinghua University Phantom Dose(THUDosePD)augments the flexibility of Monte Carlo simulations in dosi-metric research.Originating from THUDose,a code with generic,functional,and application layers,THUDosePD focuses predominantly on anatomical phantom dose assessment.Additionally,it enables medical exposure simulation,intricate geometry creation,and supports both three-dimensional radiation dose analysis and phantom format transformations.The system operates on a multi-threaded parallel CPU architecture,with some modules enhanced for GPU parallel computing.Benchmark tests on the ICRP reference male illustrated the capabilities of THUDosePD in phantom dose assessment,covering the effective dose,three-dimensional dose distribution,and three-dimensional organ dose.We also conducted a voxelization conversion on the polygon mesh phantom,demonstrating the method’s efficiency and consistency.Extended applications based on THUDosePD further underline its broad adaptability.This intuitive,three-dimensional platform stands out as a valuable tool for phantom radiation dosimetry research.
基金National Institutes of Health,Grant/Award Number:EB023969 and HL154687。
文摘Background:As mammography X-ray imaging technologies advance and provide elevated contrast in soft tissues,a need has developed for reliable imaging phantoms for use in system design and component calibration.In advanced imaging modalities such as refraction-based methods,it is critical that developed phantoms capture the biological details seen in clinical precancerous and cancerous cases while minimizing artifacts that may be caused due to phantom production.This work presents the fabrication of a breast tissue imaging phantom from cadaveric breast tissue suitable for use in both transmission and refraction-enhanced imaging systems.Methods:Human cancer cell tumors were grown orthotopically in nude athymic mice and implanted into the fixed tissue while maintaining the native tumor/adipose tissue interface.Results:The resulting human–murine tissue hybrid phantom was mounted on a clear acrylic housing for absorption and refraction X-ray imaging.Digital breast tomosynthesis was also performed.Conclusion:Both attenuation-based imaging and refraction-based imaging of the phantom are presented to confirm the suitability of this phantom's use in both imaging modalities.
文摘Introduction: The ring vortex phantom is a novel, cost-effective prototype which generates complex and well-characterised reference flows in the form of the ring vortex. Although its reproducibility has been demonstrated, with ring speeds routinely behaving within 10% tolerances at speeds of approximately 10 - 70 cm/s, a form of real-time QA of the device at the time of imaging is needed to confirm correct function on demand in any environment. Methods: The technology described here achieves real-time QA, comprising a linear encoder, laser-photodiode array, and Doppler probe, measuring piston motion, ring speed and intra-ring velocity respectively. This instrumentation does not interfere with imaging system QA, but allows QA to be performed on both the ring vortex and the device in real-time. Results: The encoder reports the reliability of the piston velocity profile, whilst ring speed is measured by laser behaviour. Incorporation of a calibrated Doppler probe offers a consistency check that confirms behaviour of the central axial flow. For purposes of gold-standard measurement, all elements can be related to previous Laser PIV acquisitions with the same device settings. Conclusion: Consequently, ring vortex production within tolerances is confirmed by this instrumentation, delivering accurate QA in real-time. This implementation offers a phantom QA procedure that exceeds anything seen in the literature, providing the technology to enhance quantitative assessment of flow imaging modalities.
文摘Successfully utilized non-axisymmetric endwalls to enhance turbine efficiencies(aerodynamic and turbine inlet temperatures)by controlling the characteristics of the secondary flow in a blade passage.This is accomplished by steady-state numerical hydrodynamics and deep knowledge of the field of flow.Because of the interaction between mainstream and purge flow contributing supplementary losses in the stage,non-axisymmetric endwalls are highly susceptible to the inception of purge flow exit compared to the flat and any advantage rapidly vanishes.The conclusions reveal that the supreme endwall pattern could yield a lowering of the gross pressure loss at the design stage and is related to the size of the top-loss location being productively lowered.This has led to diminished global thermal exchange lowered in the passage of the vane alone.The reverse flow adjacent to the suction side corner of the endwall is migrated farther from the vane surface,as the deviated pressure spread on the endwall accelerates the flow and progresses the reverse flow core still downstream.The depleted association between the tornado-like vortex and the corner vortex adjacent to the suction side corner of the endwall is the dominant mechanism of control in the contoured end wall.In this publication,we show that the non-axisymmetric endwall contouring by selective numerical shape change method at most prominent locations is advantageous in lowering the thermal load in turbines to augment the net heat flux reduction as well as the aerodynamic performance using multi-objective optimization.