The compound bioceramic coating containing calcium (Ca) and phosphorus (P) on titanium alloy substrate was prepared by means of micro-arc oxidation (MAO) treatment. The results show that under the different electrolyt...The compound bioceramic coating containing calcium (Ca) and phosphorus (P) on titanium alloy substrate was prepared by means of micro-arc oxidation (MAO) treatment. The results show that under the different electrolyte the coating with the color of gray or black and surface morphology of cauliflower or honeycomb, where Ca content and P contain can attain 30% and 20% respectively, can be obtained. Meanwhile, the influences of electrolyte temperature, current density and discharge time on morphology and thickness of coating are also discussed here.展开更多
We put forward a protocolcombining laser treatment and acid etching to obtain multiscale micro/nano-texture surfaces of titanium alloy implant.Firstly,the operationalparameters of the laser were optimized to obtain an...We put forward a protocolcombining laser treatment and acid etching to obtain multiscale micro/nano-texture surfaces of titanium alloy implant.Firstly,the operationalparameters of the laser were optimized to obtain an optimum current.Secondly,the laser with the optimum operationalparameters was used to fabricate micro pits.Thirdly,multiple acid etching was used to clean the clinkers of micro pits and generate submicron and nanoscale structures.Finally,the bioactivity of the samples was measured in a simulated body fluid.The results showed that the micropits with a diameter of 150 μm and depth of 50 μm were built successfully with the optimized working current of 13 A.In addition,submicron and nanoscale structures,with 0.5-2 μm microgrooves and 10-20 nm nanopits,were superimposed on micro pits surface by multiple acid etching.There was thick and dense HA coating only observed on the multiscale micro/nano-textured surface compared with polished and micro-textured surface.This indicated that the multiscale micro/nano-texture surface showed better ability toward HA formation,which increased the bioactivity of implants.展开更多
Electron beam welding of Ti-15-3 titanium alloy to 304 stainless steel with a copper sheet as interlayer was carried out.Microstructures of the joint were studied by optical microscopy(OM),scanning electron microscopy...Electron beam welding of Ti-15-3 titanium alloy to 304 stainless steel with a copper sheet as interlayer was carried out.Microstructures of the joint were studied by optical microscopy(OM),scanning electron microscopy(SEM) and X-ray diffractometry(XRD).In addition,the mechanical properties of the joint were evaluated by tensile test and the microhardness was measured.These two alloys were successfully welded by adding copper transition layer into the weld.Solid solution with a certain thickness was located at the interfaces between weld and base metal in both sides.Regions inside the weld and near the stainless steel were characterized by solid solution of copper with TiFe2 intermetallics dispersedly distributed in it.While weld near titanium alloy contained Ti-Cu and Ti-Fe-Cu intermetallics layer,in which the hardness of weld came to the highest value.Brittle fracture occurred in the intermetallics layer when the joint was stretched.展开更多
Micro-arc oxidation(MAO)coating was prepared on Ti6Al4V alloy surface and its characterizations were detected by Vickers hardness tester,profilometer,scanning electric microscope(SEM),energy dispersive X-ray spectrome...Micro-arc oxidation(MAO)coating was prepared on Ti6Al4V alloy surface and its characterizations were detected by Vickers hardness tester,profilometer,scanning electric microscope(SEM),energy dispersive X-ray spectrometer(EDX)and X-ray diffractometer(XRD).Fretting wear behaviors of the coating and its substrate were comparatively tested without lubrication under varied displacement amplitudes(D)in a range of 3-40μm,constant normal load(Fn)of 300 N and frequency of 5 Hz.The results showed that the MAO coating,presenting rough and porous surface and high hardness,mainly consisted of rutile and anatase TiO2 phases.Compared with the substrate,the MAO coating could shift the mixed fretting regime(MFR)and slip regime(SR)to a direction of smaller displacement amplitude.In the partial slip regime(PSR),lower friction coefficients and slight damage appeared due to the coordination of elastic deformation of contact zones.In the MFR,the friction coefficient of the coating was lower than that of the substrate as a result of the prevention of plastic deformation by the hard ceramic surface.With the increase of the displacement amplitude,the degradation of the MAO coating and the substrate increased extremely.The fretting wear mechanisms of the coating were abrasive wear and delamination with some material transfer of specimen.In addition,the coating presented a better property for alleviating fretting wear.展开更多
Short tool life and rapid tool wear in micromachining of hard-to-machine materials remain a barrier to the process being economically viable. In this study, standard procedures and conditions set by the ISO for tool l...Short tool life and rapid tool wear in micromachining of hard-to-machine materials remain a barrier to the process being economically viable. In this study, standard procedures and conditions set by the ISO for tool life testing in milling were used to analyze the wear of tungsten carbide micro-end-milling tools through slot milling conducted on titanium alloy Ti-6 Al-4 V. Tool wear was characterized by flank wear rate,cutting-edge radius change, and tool volumetric change. The effect of machining parameters, such as cutting speed and feedrate, on tool wear was investigated with reference to surface roughness and geometric accuracy of the finished workpiece. Experimental data indicate different modes of tool wear throughout machining, where nonuniform flank wear and abrasive wear are the dominant wear modes. High cutting speed and low feedrate can reduce the tool wear rate and improve the tool life during micromachining.However, the low feedrate enhances the plowing effect on the cutting zone, resulting in reduced surface quality and leading to burr formation and premature tool failure. This study concludes with a proposal of tool rejection criteria for micro-milling of Ti-6 Al-4 V.展开更多
Recently, minimally invasive surgeries using guide-wire, catheter, stent etc. have spread rapidly as the diagnosis and the medical treatment for a cancer, a disease in a circulatory organ etc. Currently, further maneu...Recently, minimally invasive surgeries using guide-wire, catheter, stent etc. have spread rapidly as the diagnosis and the medical treatment for a cancer, a disease in a circulatory organ etc. Currently, further maneuverability and functionability of those devices are strongly desired in order to be used widely and safely. Although Ti-Ni shape memory alloys have been used in medical devices such orthodontic wire, guide-wire, it has been suspected that Ni is allergenic and carcinogenic to the human body. Thus the development of Ni-free shape memory alloys has been strongly required. Recently, several Ni-free beta-titanium alloys such as Ti-Mo-Al, Ti-Mo-Ga, Ti-Nb-Al have been developed as new-type shape memory alloys. We have been studying Ti-Mo based beta-titanium alloys and Ti-Mo-Sn alloy has constantly super elasticity of 3%.The purpose of present study is to propose the micro catheter with thin wall and high flexibility using To-Mo-Sn alloys tube on the basis of its mechanical properties.展开更多
文摘The compound bioceramic coating containing calcium (Ca) and phosphorus (P) on titanium alloy substrate was prepared by means of micro-arc oxidation (MAO) treatment. The results show that under the different electrolyte the coating with the color of gray or black and surface morphology of cauliflower or honeycomb, where Ca content and P contain can attain 30% and 20% respectively, can be obtained. Meanwhile, the influences of electrolyte temperature, current density and discharge time on morphology and thickness of coating are also discussed here.
基金Funded by the National Natural Science Foundation of China(51175306 and 51575320)the Tai Shan Scholar Foundation(TS20130922)the Fundamental Research Funds for the Central Universities(2014JC020)
文摘We put forward a protocolcombining laser treatment and acid etching to obtain multiscale micro/nano-texture surfaces of titanium alloy implant.Firstly,the operationalparameters of the laser were optimized to obtain an optimum current.Secondly,the laser with the optimum operationalparameters was used to fabricate micro pits.Thirdly,multiple acid etching was used to clean the clinkers of micro pits and generate submicron and nanoscale structures.Finally,the bioactivity of the samples was measured in a simulated body fluid.The results showed that the micropits with a diameter of 150 μm and depth of 50 μm were built successfully with the optimized working current of 13 A.In addition,submicron and nanoscale structures,with 0.5-2 μm microgrooves and 10-20 nm nanopits,were superimposed on micro pits surface by multiple acid etching.There was thick and dense HA coating only observed on the multiscale micro/nano-textured surface compared with polished and micro-textured surface.This indicated that the multiscale micro/nano-texture surface showed better ability toward HA formation,which increased the bioactivity of implants.
文摘Electron beam welding of Ti-15-3 titanium alloy to 304 stainless steel with a copper sheet as interlayer was carried out.Microstructures of the joint were studied by optical microscopy(OM),scanning electron microscopy(SEM) and X-ray diffractometry(XRD).In addition,the mechanical properties of the joint were evaluated by tensile test and the microhardness was measured.These two alloys were successfully welded by adding copper transition layer into the weld.Solid solution with a certain thickness was located at the interfaces between weld and base metal in both sides.Regions inside the weld and near the stainless steel were characterized by solid solution of copper with TiFe2 intermetallics dispersedly distributed in it.While weld near titanium alloy contained Ti-Cu and Ti-Fe-Cu intermetallics layer,in which the hardness of weld came to the highest value.Brittle fracture occurred in the intermetallics layer when the joint was stretched.
基金Project(50521503)supported by the National Natural Science Foundation of ChinaProject(2007CB714704)supported by the National Basic Research Program of ChinaProject(200536)supported by the Foundation of the Author of National Excellent Doctoral Dissertation of China
文摘Micro-arc oxidation(MAO)coating was prepared on Ti6Al4V alloy surface and its characterizations were detected by Vickers hardness tester,profilometer,scanning electric microscope(SEM),energy dispersive X-ray spectrometer(EDX)and X-ray diffractometer(XRD).Fretting wear behaviors of the coating and its substrate were comparatively tested without lubrication under varied displacement amplitudes(D)in a range of 3-40μm,constant normal load(Fn)of 300 N and frequency of 5 Hz.The results showed that the MAO coating,presenting rough and porous surface and high hardness,mainly consisted of rutile and anatase TiO2 phases.Compared with the substrate,the MAO coating could shift the mixed fretting regime(MFR)and slip regime(SR)to a direction of smaller displacement amplitude.In the partial slip regime(PSR),lower friction coefficients and slight damage appeared due to the coordination of elastic deformation of contact zones.In the MFR,the friction coefficient of the coating was lower than that of the substrate as a result of the prevention of plastic deformation by the hard ceramic surface.With the increase of the displacement amplitude,the degradation of the MAO coating and the substrate increased extremely.The fretting wear mechanisms of the coating were abrasive wear and delamination with some material transfer of specimen.In addition,the coating presented a better property for alleviating fretting wear.
基金the Engineering and Physical Sciences Research Council (EP/M020657/1) for the support for this work
文摘Short tool life and rapid tool wear in micromachining of hard-to-machine materials remain a barrier to the process being economically viable. In this study, standard procedures and conditions set by the ISO for tool life testing in milling were used to analyze the wear of tungsten carbide micro-end-milling tools through slot milling conducted on titanium alloy Ti-6 Al-4 V. Tool wear was characterized by flank wear rate,cutting-edge radius change, and tool volumetric change. The effect of machining parameters, such as cutting speed and feedrate, on tool wear was investigated with reference to surface roughness and geometric accuracy of the finished workpiece. Experimental data indicate different modes of tool wear throughout machining, where nonuniform flank wear and abrasive wear are the dominant wear modes. High cutting speed and low feedrate can reduce the tool wear rate and improve the tool life during micromachining.However, the low feedrate enhances the plowing effect on the cutting zone, resulting in reduced surface quality and leading to burr formation and premature tool failure. This study concludes with a proposal of tool rejection criteria for micro-milling of Ti-6 Al-4 V.
文摘Recently, minimally invasive surgeries using guide-wire, catheter, stent etc. have spread rapidly as the diagnosis and the medical treatment for a cancer, a disease in a circulatory organ etc. Currently, further maneuverability and functionability of those devices are strongly desired in order to be used widely and safely. Although Ti-Ni shape memory alloys have been used in medical devices such orthodontic wire, guide-wire, it has been suspected that Ni is allergenic and carcinogenic to the human body. Thus the development of Ni-free shape memory alloys has been strongly required. Recently, several Ni-free beta-titanium alloys such as Ti-Mo-Al, Ti-Mo-Ga, Ti-Nb-Al have been developed as new-type shape memory alloys. We have been studying Ti-Mo based beta-titanium alloys and Ti-Mo-Sn alloy has constantly super elasticity of 3%.The purpose of present study is to propose the micro catheter with thin wall and high flexibility using To-Mo-Sn alloys tube on the basis of its mechanical properties.