期刊文献+
共找到5,800篇文章
< 1 2 250 >
每页显示 20 50 100
Technetium-99m-methylene diphosphonate single photon emission computed tomography/computed tomography combined with prostate-specific antigen/free prostate-specific antigen ratio for bone metastasis of prostate cancer
1
作者 Jian He Yi-Pu Zhong Shuang Zhang 《World Journal of Clinical Cases》 SCIE 2024年第20期4082-4090,共9页
BACKGROUND Prostate cancer(PC)is one of the most common malignant tumors in men,and bone metastasis is one of its common complications,which seriously affects the quality of life and prognosis of patients.AIM To inves... BACKGROUND Prostate cancer(PC)is one of the most common malignant tumors in men,and bone metastasis is one of its common complications,which seriously affects the quality of life and prognosis of patients.AIM To investigate the diagnostic value of technetium-99m-methylene diphosphonate(99mTc-MDP)single photon emission computed tomography(SPECT)/CT imaging combined with the serum prostate-specific antigen(PSA)/free PSA ratio for PC bone metastasis(PCBM).METHODS One hundred patients with PC who visited the Hospital of Chengdu University of Traditional Chinese Medicine from January 2020 to January 2022 were recruited as the experimental(Exp)group,while 30 patients with benign prostatic lesions(BPLs)were recruited as the control(Ctrl)group.All patients underwent 99mTc-MDP SPECT/CT imaging and serum PSA/fPSA testing.The SPECT/CT imaging results and serum PSA/fPSA ratios of patients were analyzed to evaluate their diagnostic values for PCBM.RESULTS The difference in general information of the patients was not obvious,showing comparability.The two methods showed no visible differences in negative predictive value and sensitivity for patients with PCBM,but had great differences in positive predictive value and specificity(P<0.05).The PSA/fPSA ratio of patients with PC in the Exp group was lower than those with BPLs,and patients with PCBM had a much lower PSA/fPSA ratio than those without PC(P<0.05).The results confirmed that the combined use of 99mTc-MDP SPECT/CT imaging and serum PSA/fPSA ratio achieved a detection rate of 95%for PCBM.CONCLUSION The combination of 99mTc-MDP SPECT/CT and PSA/fPSA ratio is accurate and reliable for the diagnosis of PCBM,which provides an important reference for clinical practice. 展开更多
关键词 Matrix metalloproteinase 9 Single photon emission computed tomography Prostate-specific antigen to free prostate-specific antigen ratio Prostate cancer Bone metastasis
下载PDF
Pancreatic neuroendocrine tumor detected by technetium-99m methoxy-2-isobutylisonitrile single photon emission computed tomography/computed tomography:A case report
2
作者 Chang-Jiang Liu Hua-Jun Yang +1 位作者 Yan-Chun Peng De-Yu Huang 《World Journal of Clinical Cases》 SCIE 2023年第12期2825-2831,共7页
BACKGROUND Pancreatic neuroendocrine tumors(NETs)account for about 1%–2%of pancreatic tumors and about 8%of all NETs.Computed tomography(CT),magnetic resonance imaging,and endoscopic ultrasound are common imaging mod... BACKGROUND Pancreatic neuroendocrine tumors(NETs)account for about 1%–2%of pancreatic tumors and about 8%of all NETs.Computed tomography(CT),magnetic resonance imaging,and endoscopic ultrasound are common imaging modalities for the diagnosis of pancreatic NETs.Furthermore,somatostatin receptor imaging is of great value for diagnosing pancreatic NETs.Herein,we report the efficacy of technetium-99m methoxy-2-isobutylisonitrile(99mTc-MIBI)single photon emission CT(SPECT)/CT for detecting pancreatic NETs.CASE SUMMARY A 57-year-old woman presented to our hospital with a 1-d history of persistent upper abdominal distending pain.The distending pain in the upper abdomen was aggravated after eating,with nausea and retching.Routine blood test results showed a high neutrophil percentage,low leukomonocyte and monocyte percentages,and low leukomonocyte and eosinophil counts.Amylase,liver and kidney function,and tumor markers alpha-fetoprotein,carcinoembryonic antigen,and cancer antigen(CA)125,CA72-4,CA19-9,and CA153 were normal.Abdominal CT showed a mass,with multiple calcifications between the pancreas and the spleen.The boundary between the mass and the pancreas and spleen was poorly defined.Contrast-enhanced CT revealed that the upper abdominal mass was unevenly and gradually enhanced.99mTc-MIBI SPECT/CT revealed that a focal radioactive concentration,with mild radioactive concentration extending into the upper abdominal mass,was present at the pancreatic body and tail.The 99mTc-MIBI SPECT/CT manifestations were consistent with the final pathological diagnosis of pancreatic NET.CONCLUSION 99mTc-MIBI SPECT/CT appears to be a valuable tool for detecting pancreatic NETs. 展开更多
关键词 Neuroendocrine tumors PANCREAS Tc-99m-Methoxy-2-isobutylisonitrile Single photon emission computed tomography X-ray computed tomography Case report
下载PDF
Rare finding of primary aortoduodenal fistula on single-photon emission computed tomography/computed tomography of gastrointestinal bleeding: A case report
3
作者 Chun-Liang Kuo Ching-Fu Chen +2 位作者 Wen-Ko Su Rong-Hsin Yang Yu-Hong Chang 《World Journal of Clinical Cases》 SCIE 2023年第29期7162-7169,共8页
BACKGROUND Primary aortoduodenal fistula is a rare cause of gastrointestinal(GI)bleeding consisting of abnormal channels between the aorta and GI tract without previous vascular intervention that results in massive in... BACKGROUND Primary aortoduodenal fistula is a rare cause of gastrointestinal(GI)bleeding consisting of abnormal channels between the aorta and GI tract without previous vascular intervention that results in massive intraluminal hemorrhage.CASE SUMMARY A 67-year-old man was hospitalized for coffee ground vomiting,tarry stools,and colic abdominal pain.He was repeatedly admitted for active GI bleeding and hypovolemic shock.Intermittent and spontaneously stopped bleeders were undetectable on multiple GI endoscopy,angiography,computed tomography angiography(CTA),capsule endoscopy,and ^(99)mTc-labeled red blood cell(RBC)scans.The patient received supportive treatment and was discharged without signs of rebleeding.Thereafter,he was re-admitted for bleeder identification.Repeated CTA after a bleed revealed a small aortic aneurysm at the renal level contacting the fourth portion of the duodenum.A ^(99)mTc-labeled RBC singlephoton emission CT(SPECT)/CT scan performed during bleeding symptoms revealed active bleeding at the duodenal level.According to his clinical symptoms(intermittent massive GI bleeding with hypovolemic shock,dizziness,dark red stool,and bloody vomitus)and the abdominal CTA and ^(99)mTc-labeled RBC SPECT/CT results,we suspected a small aneurysm and an aortoduodenal fistula.Subsequent duodenal excision and duodenojejunal anastomosis were performed.A 7-mm saccular aneurysm arising from the anterior wall of the abdominal aorta near the left renal artery was identified.Percutaneous intravascular stenting of the abdominal aorta was performed and his symptoms improved.CONCLUSION Our findings suggest that ^(99)mTc-labeled RBC SPECT/CT scanning can aid the diagnosis of a rare cause of active GI bleeding. 展开更多
关键词 Gastrointestinal active bleeding computed tomography angiography 99mTc-labeled red blood cell scan Singlephoton emission computed tomography/computed tomography Primary aortoduodenal fistula Case report
下载PDF
Evaluation of response to gemcitabine plus cisplatin-based chemotherapy using positron emission computed tomography for metastatic bladder cancer
4
作者 HakanÖztürk İnançKarapolat 《World Journal of Clinical Cases》 SCIE 2023年第36期8447-8457,共11页
BACKGROUND The purpose of the present study was to examine retrospectively the contribution of 18Fluorodeoxyglucose positron emission tomography computed tomography(18FDG-PET/CT)to the evaluation of response to first-... BACKGROUND The purpose of the present study was to examine retrospectively the contribution of 18Fluorodeoxyglucose positron emission tomography computed tomography(18FDG-PET/CT)to the evaluation of response to first-line gemcitabine plus cispla-tin-based chemotherapy in patients with metastatic bladder cancer.AIM To evaluate the response to Gemcitabine plus Cisplatin-based chemotherapy using 18FDG-PET/CT imaging in patients with metastatic bladder cancer.METHODS Between July 2007 and April 2019,79 patients underwent 18FDG-PET/CT imaging with the diagnosis of Metastatic Bladder Carcinoma(M-BCa).A total of 42 pa-tients(38 male,4 female)were included in the study,and all had been admi-nistered Gemcitabine plus Cisplatin-based chemotherapy.After completion of the therapy,the patients underwent a repeat 18FDG-PET/CT scan and the results were compared with the PET/CT findings before chemotherapy according to European Organisation for the Research and treatment of cancer criteria.Mean age was 66.1 years and standard deviation was 10.7 years(range:41–84 years).RESULTS Of the patients,seven(16.6%)were in complete remission,17(40.5%)were in partial remission,six(14.3%)had a stable disease,and 12(28.6%)had a pro-gressive disease.The overall response rate was 57.1 percent.CONCLUSION 18FDG-PET/CT can be considered as a successful imaging tool in evaluating response to first-line chemotherapy for metastatic bladder cancer.Anatomical and functional data obtained from PET/CT scans may be useful in the planning of secondline and thirdline chemotherapy. 展开更多
关键词 Metastatic bladder cancer Response to chemotheraphy Positron emission tomography computed tomography 18FDG-PET/CT
下载PDF
Significance of functional hepatic resection rate calculated using 3D CT/^(99m)Tc-galactosyl human serum albumin singlephoton emission computed tomography fusion imaging 被引量:6
5
作者 Yosuke Tsuruga Toshiya Kamiyama +6 位作者 Hirofumi Kamachi Shingo Shimada Kenji Wakayama Tatsuya Orimo Tatsuhiko Kakisaka Hideki Yokoo Akinobu Taketomi 《World Journal of Gastroenterology》 SCIE CAS 2016年第17期4373-4379,共7页
AIM: To evaluate the usefulness of the functional hepatic resection rate (FHRR) calculated using 3D computed tomography (CT)/<sup>99m</sup>Tc-galactosyl-human serum albumin (GSA) single-photon emission com... AIM: To evaluate the usefulness of the functional hepatic resection rate (FHRR) calculated using 3D computed tomography (CT)/<sup>99m</sup>Tc-galactosyl-human serum albumin (GSA) single-photon emission computed tomography (SPECT) fusion imaging for surgical decision making.METHODS: We enrolled 57 patients who underwent bi- or trisectionectomy at our institution between October 2013 and March 2015. Of these, 26 patients presented with hepatocellular carcinoma, 12 with hilar cholangiocarcinoma, six with intrahepatic cholangiocarcinoma, four with liver metastasis, and nine with other diseases. All patients preoperatively underwent three-phase dynamic multidetector CT and <sup>99m</sup>Tc-GSA scintigraphy. We compared the parenchymal hepatic resection rate (PHRR) with the FHRR, which was defined as the resection volume counts per total liver volume counts on 3D CT/<sup>99m</sup>Tc-GSA SPECT fusion images.RESULTS: In total, 50 patients underwent bisectionectomy and seven underwent trisectionectomy. Biliary reconstruction was performed in 15 patients, including hepatopancreatoduodenectomy in two. FHRR and PHRR were 38.6 &#x000b1; 19.9 and 44.5 &#x000b1; 16.0, respectively; FHRR was strongly correlated with PHRR. The regression coefficient for FHRR on PHRR was 1.16 (P &#x0003c; 0.0001). The ratio of FHRR to PHRR for patients with preoperative therapies (transcatheter arterial chemoembolization, radiation, radiofrequency ablation, etc.), large tumors with a volume of &#x0003e; 1000 mL, and/or macroscopic vascular invasion was significantly smaller than that for patients without these factors (0.73 &#x000b1; 0.19 vs 0.82 &#x000b1; 0.18, P &#x0003c; 0.05). Postoperative hyperbilirubinemia was observed in six patients. Major morbidities (Clavien-Dindo grade &#x02265; 3) occurred in 17 patients (29.8%). There was no case of surgery-related death.CONCLUSION: Our results suggest that FHRR is an important deciding factor for major hepatectomy, because FHRR and PHRR may be discrepant owing to insufficient hepatic inflow and congestion in patients with preoperative therapies, macroscopic vascular invasion, and/or a tumor volume of &#x0003e; 1000 mL. 展开更多
关键词 99mTc-galactosyl human serum albumin Single-photon emission computed tomography HEPATECTOMY Functional hepatic resection rate Parenchymal hepatic resection rate
下载PDF
Hepatic clearance measured with ^(99m)Tc-GSA single-photon emission computed tomography to estimate liver fibrosis 被引量:12
6
作者 Masahiko Taniguchi Atsutaka Okizaki +6 位作者 Kenji Watanabe Koji Imai Koichiro Uchida Takahiro Einama Noriyuki Shuke Naoyuki Miyokawa Hiroyuki Furukawa 《World Journal of Gastroenterology》 SCIE CAS 2014年第44期16714-16720,共7页
AIM: To evaluate the clinical utility of hepatic clearance(HC) measured with technetium-99m-diethylenetriaminepenta-acetic acid-galactosyl human serum albumin(99mTc-GSA) single-photon emission computed tomography(SPEC... AIM: To evaluate the clinical utility of hepatic clearance(HC) measured with technetium-99m-diethylenetriaminepenta-acetic acid-galactosyl human serum albumin(99mTc-GSA) single-photon emission computed tomography(SPECT) to estimate the degree of liver fibrosis.METHODS:Seventy-eight consecutive patients who underwent initial hepatectomy due to hepatocellular carcinoma were enrolled in this study.Indocyanine green clearance(ICG R15),quantitative indices estimated by 99mTc-GSA[the receptor index(LHL15 and HH15)and HC via SPECT analysis],and conventional liver function tests were performed before hepatectomy.Correlations among the quantitative indices for liver functional reserve,conventional liver function tests,andthe degree of liver fibrosis were evaluated.RESULTS:The degree of liver fibrosis was correlated with ICG R15,HH15,LHL15,and HC.HC showed the best correlation with conventional liver function tests.According to multivariate analysis,HC and LHL15 were significant independent predictors of severe fibrosis.HC was the most valuable index for predicting severe fibrosis.CONCLUSION:HC measured with 99mTc-GSA SPECT is a reliable index for assessing liver fibrosis before hepatectomy. 展开更多
关键词 FIBROSIS Technetium-99m-diethylenetri-aminepenta-acetic acid-galactosyl human serum albu-min Single-photon emission computed tomography Hepatic clearance Liver resection
下载PDF
Cerebral functional imaging of Waiguan (SJ 5) acupoint specificity using single-photon emission computed tomography 被引量:2
7
作者 Yong Huang Yangjia Lu +5 位作者 Ganlong Li Xinsheng Lai Hong Zhang Chunzhi Tang JunjunYang Gustav Wik 《Neural Regeneration Research》 SCIE CAS CSCD 2011年第6期428-434,共7页
The action of needling in acupoint therapy has to first be regulated and integrated by the brain, and then it affects the target organ and manifests its therapeutic effects, which is dependent on the specificity of th... The action of needling in acupoint therapy has to first be regulated and integrated by the brain, and then it affects the target organ and manifests its therapeutic effects, which is dependent on the specificity of the acupoints. The authors put forward the hypothesis of the "acupoint-related brain". Single-photon emission computed tomography was used to explore the activation of brain regions following true needling in true acupoint Waiguan (SJ 5), sham needling in true acupoint Waiguan, true needling in a sham point, and sham needling in a sham point. The relative specificity of Waiguan in normal persons was analyzed by observing changes in regional cerebral blood flow. Compared with the sham needling in true acupoint group and sham needling in the sham point group, acupuncture at Waiguan can activate brain regions controlling movement. Compared with true needling in the sham point group, acupuncture at Waiguan can also activate brain regions controlling movement. The results suggest that the specificity of needling at an acupoint is related to certain activated cerebral functional regions, which are associated with the clinical application of the acupoint. 展开更多
关键词 acupoint specificity Waiguan (SJ 5) NEEDLING sham needling sham point single-photon emission computed tomography
下载PDF
Quantification of Tc-99m-ethyl cysteinate dimer brain single photon emission computed tomography images using statistical probabilistic brain atlas in depressive end-stage renal disease patients:Correlation with disease severity and symptom factors 被引量:1
8
作者 Heeyoung Kim In Joo Kim +3 位作者 Seong-Jang Kim Sang Heon Song Kyoungjune Pak Keunyoung Kim 《Neural Regeneration Research》 SCIE CAS CSCD 2012年第27期2151-2159,共9页
This study adapted a statistical probabilistic anatomical map of the brain for single photon emission computed tomography images of depressive end-stage renal disease patients. This research aimed to investigate the r... This study adapted a statistical probabilistic anatomical map of the brain for single photon emission computed tomography images of depressive end-stage renal disease patients. This research aimed to investigate the relationship between symptom clusters, disease severity, and cerebral blood flow. Twenty-seven patients (16 males, 11 females) with stages 4 and 5 end-stage renal disease were enrolled, along with 25 healthy controls. All patients underwent depressive mood assessment and brain single photon emission computed tomography. The statistical probabilistic anatomical map images were used to calculate the brain single photon emission computed tomography counts. Asymmetric index was acquired and Pearson correlation analysis was performed to analyze the correlation between symptom factors, severity, and regional cerebral blood flow. The depression factors of the Hamilton Depression Rating Scale showed a negative correlation with cerebral blood flow in the left amygdale. The insomnia factor showed negative correlations with cerebral blood flow in the left amygdala, right superior frontal gyrus, right middle frontal gyrus, and left middle frontal gyrus. The anxiety factor showed a positive correlation with cerebral glucose metabolism in the cerebellar vermis and a negative correlation with cerebral glucose metabolism in the left globus pailidus, right inferior frontal gyrus, both temporal poles, and left parahippocampus. The overall depression severity (total scores of Hamilton Depression Rating Scale) was negatively correlated with the statistical probabilistic anatomical map results in the left amygdala and right inferior frontal gyrus. In conclusion, our results demonstrated that the disease severity and extent of cerebral blood flow quantified by a probabilistic brain atlas was related to various brain areas in terms of the overall severity and symptom factors in end-stage renal disease patients. 展开更多
关键词 single photon emission computed tomography end-stage renal disease depression statisticalprobabilistic brain atlas disease severity cerebral blood flow SYMPTOM BRAIN neural regeneration
下载PDF
Computed tomography, magnetic resonance imaging, and Fdeoxyglucose positron emission computed tomography/computed tomography findings of alveolar soft part sarcoma with calcification in the thigh: A case report 被引量:1
9
作者 Zeng-Jie Wu Tian-Tian Bian +3 位作者 Xiao-Hong Zhan Cheng Dong Yan-Li Wang Wen-Jian Xu 《World Journal of Clinical Cases》 SCIE 2020年第15期3349-3354,共6页
BACKGROUND Alveolar soft part sarcoma(ASPS)is an extremely rare malignant sarcoma,accounting for less than 1%of all soft-tissue sarcomas.However,limited information is available on multimodal imaging[computed tomograp... BACKGROUND Alveolar soft part sarcoma(ASPS)is an extremely rare malignant sarcoma,accounting for less than 1%of all soft-tissue sarcomas.However,limited information is available on multimodal imaging[computed tomography(CT),magnetic resonance imaging(MRI),and positron emission computed tomography/computed tomography(PET/CT)]of ASPS.CASE SUMMARY This study reports a case of a 35-year-old female patient with ASPS of the left thigh with lung metastasis.The patient presented with a 1-year history of a palpable mass in the lower extremity,which exhibited rapid growth for 3 wk.CT,MRI,and F-deoxyglucose PET/CT examinations were performed.CT showed a slightly hypodense or isodense mass with patchy calcifications.On MRI examination,the mass manifested hyperintensity on T1-weighted,T2-weighted,and diffusion-weighted images with some signal voids.PET/CT images demonstrated an intensely hypermetabolic mass in the left thigh and hypermetabolic nodules in lungs.CONCLUSION ASPS should be considered as a possible diagnosis when a slow-growing mass is detected in the soft tissue of the extremities,with hyperintensity and numerous signal voids on T1-weighted,T2-weighted,and diffusion-weighted images and intense F-deoxyglucose uptake on PET/CT.ASPS can have calcifications on CT. 展开更多
关键词 Alveolar soft part sarcoma CALCIFICATION Magnetic resonance imaging Positron emission computed tomography/computed tomography Case report
下载PDF
Same day yttrium-90 radioembolization with single photon emission computed tomography/computed tomography: An opportunity to improve care during the COVID-19 pandemic and beyond 被引量:1
10
作者 Mohammad Elsayed Mohammad Loya +9 位作者 James Galt David M Schuster Zachary L Bercu Janice Newsome David Brandon Sonia Benenati Keywan Behbahani Richard Duszak Ila Sethi Nima Kokabi 《World Journal of Gastrointestinal Oncology》 SCIE 2021年第5期440-452,共13页
BACKGROUND The coronavirus disease 2019(COVID-19)pandemic has made it more challenging for patients to undergo yttrium-90(Y-90)radioembolization(RE).Same day Y-90 RE provides an opportunity to minimize logistical chal... BACKGROUND The coronavirus disease 2019(COVID-19)pandemic has made it more challenging for patients to undergo yttrium-90(Y-90)radioembolization(RE).Same day Y-90 RE provides an opportunity to minimize logistical challenges and infection risk associated with COVID-19,thus improving patient access.AIM To describe the use of same day Y-90 RE with routine single photon emission computed tomography/computed tomography(SPECT/CT)in order to optimize therapy.METHODS All patients were selected for Y-90 RE through a multidisciplinary tumor board,and were screened and tested for COVID-19 infection per institutional protocol.A same day procedure was developed,consisting of angiography,imaging,and Y-90 resin particle delivery.Routine SPECT/CT after technetium-99m macroaggregated albumin(Tc-99m MAA)administration was performed for assessment of arterial supply,personalized dosimetry,and extrahepatic activity.Post-treatment Y-90 bremsstrahlung SPECT/CT was performed for confirmation of particle delivery,by utilization of energy windowing to limit signal from previously administered Tc-99m MAA particles.RESULTS A total of 14 patients underwent same day Y-90 RE between March and June 2020.Mean lung shunt fraction was 6.13%(range 3.5%-13.1%).Y-90 RE was performed for a single lesion in 7 patients,while the remaining 7 patients had treatment of multifocal lesions.The largest lesion measured 8.3 cm.All patients tolerated the procedure well and were discharged the same day.CONCLUSION Same day Y-90 RE with resin-based microspheres is feasible,and provides an opportunity to mitigate infection risk and logistical challenges associated with the COVID-19 pandemic and beyond.We recommend consideration of SPECT/CT,especially among patients with complex malignancies,for the potential to improve outcomes and eligibility of patients to undergo same day Y-90 RE. 展开更多
关键词 Yttrium-90 radioembolization Same day Selective internal radiotherapy Transarterial radioembolization Single photon emission computed tomography/computed tomography Dosimetry COVID-19
下载PDF
Deep brain stimulation of the subthalamic nucleus treats Parkinson's disease through enhancing metabolic activity of the corpus striatum Verification by single photon emission computed tomography and positron emission tomography
11
作者 Yiqun Cao Xiaoping Zhou +2 位作者 Zhifeng Zhang Xiaowu Hu Xiufeng Jiang 《Neural Regeneration Research》 SCIE CAS CSCD 2010年第6期405-410,共6页
BACKGROUND: Subthalamic nucleus deep brain stimulation (STN DBS) for Parkinson's disease (PD) has achieved good effects, but to date the mechanism of STN DBS remains poorly understood STN DBS may increase dopami... BACKGROUND: Subthalamic nucleus deep brain stimulation (STN DBS) for Parkinson's disease (PD) has achieved good effects, but to date the mechanism of STN DBS remains poorly understood STN DBS may increase dopamine levels or metabolic activity of the corpus striatum. OBJECTIVE: To validate the effects of STN DBS on dopamine metabolism and glucose metabolism in the corpus striatum of hemiparkinsonian monkeys using single photon emission computed tomography (SPECT) and position emission tomography (PET). DESIGN, TIME AND SET'rING: A controlled animal study was performed at the Neurosurgery Laboratory, Changhai Hospital of the Second Military Medical University of Chinese PLA between January 2004 and December 2007. METHODS: Hemiparkinsonism was induced in adult Rhesus Macaque monkeys, which exhibit similar characteristics of PD in humans, through unilateral internal carotid artery infusion of 1-methy-4-phenyl-1, 2, 3, 6-tetrahydropyrindine. Following model establishment, stimulation electrodes were implanted in the right STN, and chronic high-frequency stimulation (60 μs pulse width, 130 Hz frequency, and 1.5-2.0 V pressure) was performed. MAIN OUTCOME MEASURES: The changes in dopamine transporter (DAT), D2 receptor (D2R), and glucose metabolism in the corpus striatum following STN DBS were observed using SPECT and PET. RESULTS: SPECT examination showed that DAT specific binding in the right corpus striatum was increased at 3 months after DBS compared with prior to stimulation, and D2R specific binding in the right corpus striatum gradually decreased near levels on the left (non-electrode-implanted) side within 3 months after DBS. PET examination showed that the glucose metabolism in the right corpus striatum was markedly increased at 3 months after effective DBS. Hemiparkinsonism monkeys showed improved left limb rigidity, increased activities, and stable gait under chronic high-frequency stimulation. CONCLUSION: STN DBS increased striatal DAT, decreased D2R, and enhanced glucose metabolism, suggesting that chronic, high-frequency STN stimulation enhanced the metabolic activity of the corpus striatum, a mechanism for improving the PD symptoms of hemiparkinsonian monkeys. 展开更多
关键词 subthalamic nucleus deep brain stimulation Parkinson's disease MONKEY single photon emission computed tomography positron emission tomography neural regeneration
下载PDF
ASSESSMENT OF MYOCARDIAL VIABILITY WITH CONTRAST-ENHANCED MAGNETIC RESONANCE IMAGING AND COMPARISON WITH SINGLE-PHOTON EMISSION COMPUTED TOMOGRAPHY
12
作者 Yi-ning Wang Zheng-yu Jin +6 位作者 Zhu-hua Zhang Ling-yan Kong Li-bo Chen Lu Zhou Hong-yi Sun Heng Zhang Qi Miao 《Chinese Medical Sciences Journal》 CAS CSCD 2006年第4期239-244,共6页
Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty pa... Objective To compare contrast-enhanced magnetic resonance imaging (ceMRI) with nuclear metabolic imaging for the assessment of myocardial viability in patients with chronic ischemic heart disease. Methods Twenty patients with suspected chronic ischemic heart disease underwent ceMRI and technetium-99m sestamibi single-photon emission computed tomography (SPECT). Patients with positive SPECT results also underwent 18 F-fluorodeoxyglucose (FDG) SPECT. In a 17-segment model, the segmental extent of hyperenhancement (SEH) by ceMRI was compared with segmental FDG and sestamibi uptake by SPECT. Correlation between the extent of hyperenhancement by ceMRI and left ventricular function was analyzed. Seven patients got negative results both in ceMRI and technetium-99m sestamibi SPECT. The rest 13 patients with positive results then underwent ^18F-FDG SPECT. In 221 segments of 13 patients, SEH was (2. 1±8.2)%, (25.0±13.7 )%, and (57. 7±23.6 )% in segments with normal metabolism/perfusion, metabolism/perfusion mismatch, and matched defects, respectively, and there were significant differences between either two of them ( all P 〈 0.05). By receiver operating characteristic curve analysis, the area under the curve was 0. 95 for the differentiation between viable and non-viable segments. At the cutoff value of 34%, SEH optimally differentiated viable from non-viable segments defined by SPECT. Using this threshold, the sensitivity and specificity of ceMRI to detect non-viable myocardium as defined by SPECT were 92% and 93%, respectively. Hyperenhancement size by ceMRI was correlated negatively with the left ventricular ejection fraction ( r = - 0.90, P 〈 0.01 ) and positively with left ventricular volumes ( r = 0. 62 for end-diastolic volume, r = 0.75 for end-systolic volume, both P 〈 0.05 ). Conclusion CeMRI allows assessment of myocardial viability with a high accuracy in patients with chronic ischemic heart disease. 展开更多
关键词 magnetic resonance imaging single-photon emission computed tomography myocardialviability
下载PDF
Indocyanine green plasma clearance rate and 99mTc-galactosyl human serum albumin single-photon emission computed tomography evaluated preoperative remnant liver
13
作者 Kentaro Iwaki Satoshi Kaihara +3 位作者 Ryosuke Kita Koji Kitamura Hiroki Hashida Kenji Uryuhara 《World Journal of Clinical Cases》 SCIE 2022年第25期8844-8853,共10页
BACKGROUND Preoperative evaluation of future remnant liver reserves is important for safe hepatectomy.If the remnant is small,preoperative portal vein embolization(PVE)is useful.Liver volume analysis has been the prim... BACKGROUND Preoperative evaluation of future remnant liver reserves is important for safe hepatectomy.If the remnant is small,preoperative portal vein embolization(PVE)is useful.Liver volume analysis has been the primary method of preoperative evaluation,although functional examination may be more accurate.We have used the functional evaluation liver using the indocyanine green plasma clearance rate(KICG)and 99mTc-galactosyl human serum albumin single-photon emission computed tomography(99mTc-GSA SPECT)for safe hepatectomy.AIM To analyze the safety of our institution’s system for evaluating the remnant liver reserve.METHODS We retrospectively reviewed the records of 23 patients who underwent preoperative PVE.Two types of remnant liver KICG were defined as follows:Anatomical volume remnant KICG(a-rem-KICG),determined as the remnant liver anatomical volume rate×KICG;and functional volume remnant KICG(frem-KICG),determined as the remnant liver functional volume rate based on 99mTc-GSA SPECT×KICG.If either of the remnant liver KICGs were>0.05,a hepatectomy was performed.Perioperative factors were analyzed.We defined the marginal group as patients with a-rem-KICG of<0.05 and a f-rem-KICG of>0.05 and compared the postoperative outcomes between the marginal and not marginal(both a-rem-KICG and f-rem-KICG>0.05)groups.RESULTS All 23 patients underwent planned hepatectomies.Right hepatectomy,right trisectionectomy and left trisectionectomy were in 16,6 and 1 cases,respectively.The mean of blood loss and operative time were 576 mL and 474 min,respectively.The increased amount of frem-KICG was significantly larger than that of a-rem-KICG after PVE(0.034 vs 0.012,P=0.0273).The not marginal and marginal groups had 17(73.9%)and 6(26.1%)patients,respectively.The complications of Clavian-Dindo classification grade II or higher and post-hepatectomy liver failure were observed in six(26.1%)and one(grade A,4.3%)patient,respectively.The 90-d mortality was zero.The marginal group had no significant difference in postoperative outcomes(prothrombin time/international normalised ratio,total bilirubin,complication,post-hepatectomy liver failure,hospital stay,90-d,and mortality)compared with the not-marginal group.CONCLUSION Functional evaluation of the remnant liver enabled safe hepatectomy and may extend the indication for hepatectomy after PVE treatment. 展开更多
关键词 99mTc-galactosyl human serum albumin single-photon emission computed tomography HEPATECTOMY Indocyanine green Indocyanine green plasma clearance rate Liver function evaluation Remnant liver reserve
下载PDF
Rest Thallium-201/Stress Technetium-99m Sestamibi Dual-Isotope Myocardial Perfusion Single-Photon Emission Computed Tomography in Detecting of Chronic Coronary Artery Disease
14
作者 Phuong Kim Huynh Lap Vu Cong +1 位作者 Xuan Quang Truong Canh Nguyen Xuan 《Journal of Pharmacy and Pharmacology》 2016年第5期183-191,共9页
To investigate diagnostic accuracy of 2-hour protocol of rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion SPECT in chronic coronary artery disease. Sixty-seven patients with suspecte... To investigate diagnostic accuracy of 2-hour protocol of rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion SPECT in chronic coronary artery disease. Sixty-seven patients with suspected CAD were enrolled in the prospective study. All patients underwent myocardial perfusion scintigraphy in SPECT with dual isotopes of T1-201 and dipyridamole stress Tc-99m sestamibi. Rest and stress imaging protocol were performed in 2 hours by dose of 3 mCi TI-201 and 25 mCi Tc-99m sestamibi. The acquisition parameters includes LEHR collimator, energy peak of 72 and 167 keV for T1-201 and 140 keV for Tc-99m, 180-degree rotation from RAO to LPO, matrix size 64x64, and 25second/frame/64 frames. The 20-segment model of left ventricle was used in automatic quantitation software. Coronary angiography was used as gold standard. CAD was defined as 50% of lumen stenosis on coronary angiography. Rest TI-201/stress tc-99m sestamibi dual-isotope SPECT demonstrated a sensitivity of 94.59% and specificity of 70%, positive predictive value of 79.54% and negative predictive value of 91.3% in detection of coronary artery disease. Sensitivity and specificity for detecting multi-vessel coronary artery disease were 82.75% and 81.57% for the left anterior descending, 77.77% and 91.83% for left circumflex and 94.11% and 82% for right coronary artery. 2-hour protocol of rest thallium-201/stress technetium-99m sestamibi dual-isotope myocardial perfusion SPECT has high sensitivity, specificity, positive predictive value and negative predictive value in detecting chronic coronary artery disease with greater than 50% stenosis assessed by coronary angiography Moreover, this imaging protocol gives high imaging quality, time-saving and convenience. 展开更多
关键词 MPS (myocardial perfusion scintigarphy) SPECT (single proton emission computed tomography) CAD (coronary arterydisease) CA (coronary angiography).
下载PDF
Endocrine radionuclide scintigraphy with fusion single photon emission computed tomography/computed tomography 被引量:4
15
作者 Ka-Kit Wong Arpit Gandhi +3 位作者 Benjamin L Viglianti Lorraine M Fig Domenico Rubello Milton D Gross 《World Journal of Radiology》 CAS 2016年第6期635-655,共21页
AIM: To review the benefits of single photon emission computed tomography(SPECT)/computed tomography(CT) hybrid imaging for diagnosis of various endocrine disorders.METHODS: We performed MEDLINE and Pub Med searches u... AIM: To review the benefits of single photon emission computed tomography(SPECT)/computed tomography(CT) hybrid imaging for diagnosis of various endocrine disorders.METHODS: We performed MEDLINE and Pub Med searches using the terms: "SPECT/CT"; "functional anatomic mapping"; "transmission emission tomography"; "parathyroid adenoma"; "thyroid cancer"; "neuroendocrine tumor"; "adrenal"; "pheochromocytoma"; "paraganglioma"; in order to identify relevant articles published in English during the years 2003 to 2015. Reference lists from the articles were reviewed to identify additional pertinent articles. Retrieved manuscripts(case reports, reviews, meta-analyses and abstracts) concerning the application of SPECT/CT to endocrine imaging were analyzed to provide a descriptive synthesis of the utility of this technology.RESULTS: The emergence of hybrid SPECT/CT camera technology now allows simultaneous acquisition of combined multi-modality imaging, with seamless fusion of three-dimensional volume datasets. The usefulness of combining functional information to depict the biodistribution of radiotracers that map cellular processes of the endocrine system and tumors of endocrine origin, with anatomy derived from CT, has improved the diagnostic capability of scintigraphy for a range of disorders of endocrine gland function. The literature describes benefits of SPECT/CT for ^(99m)Tc-sestamibi parathyroid scintigraphy and ^(99m)Tc-pertechnetate thyroid scintigraphy, ^(123)I- or ^(131)I-radioiodine for staging of differentiated thyroid carcinoma, ^(111)In- and ^(99m)Tclabeled somatostatin receptor analogues for detection of neuroendocrine tumors, ^(131)I-norcholesterol(NP-59) scans for assessment of adrenal cortical hyperfunction, and ^(123)I- or ^(131)I-metaiodobenzylguanidine imaging for evaluation of pheochromocytoma and paraganglioma.CONCLUSION: SPECT/CT exploits the synergism between the functional information from radiopharmaceutical imaging and anatomy from CT, translating to improved diagnostic accuracy and meaningful impact on patient care. 展开更多
关键词 Parathyroid adenoma Neuroendocrine tumor SINGLE PHOTON emission computed tomography/ computed TOMOGRAPHY SINGLE PHOTON emission computed tomography-computed TOMOGRAPHY Thyroid cancer Pheochromocytoma PARAGANGLIOMA
下载PDF
Three-dimensional stereotactic surface projection in the statistical analysis of single photon emission computed tomography data for distinguishing between Alzheimer's disease and depression 被引量:1
16
作者 Eiji Kirino 《World Journal of Psychiatry》 SCIE 2017年第2期121-127,共7页
AIM To evaluate usefulness of single photon emission computed tomography(SPECT) with three-dimensional stereotactic surface projection(3D-SSP) in distinguishing between Alzheimer's disease(AD) and depression.METHO... AIM To evaluate usefulness of single photon emission computed tomography(SPECT) with three-dimensional stereotactic surface projection(3D-SSP) in distinguishing between Alzheimer's disease(AD) and depression.METHODS We studied 43 patients who presented with both depressive symptoms and memory disturbance. Each subject was evaluated using the following:(1) the Minimal Mental State Examination;(2) the Hamilton Rating Scale for Depression;(3) Clinical Global Impression-Severity scale(CGI-S); and(4) SPECT imaging with 3D-SSP.RESULTS The MMSE scores correlated significantly with the maximum Z-scores of AD-associated regions. CGI-S scores correlated significantly with the maximum Z-scores of depression-associated regions. Factor analysis identified three significant factors. Of these, Factor 1 could be interpreted as favouring a tendency for AD, Factor 2 as favouring a tendency for pseudo-dementia, and Factor 3 as favouring a depressive tendency.CONCLUSION We investigated whether these patients could be categorized as types: Type A(true AD), Type B(pseudodementia), Type C(occult AD), and Type D(true depression). The factor scores in factor analysis supported the validity of this classification. Our results suggest that SPECT with 3D-SSP is highly useful for distinguishing between depression and depressed mood in the early stage of AD. 展开更多
关键词 Alzheimer’s disease THREE-DIMENSIONAL STEREOTACTIC surface projection Single photon emission computed tomography Pseudo-dementia DEPRESSION
下载PDF
Dopamine transporter distribution in patients with Parkinson disease of different stages detected using single-photon emission computed tomography brain imaging
17
作者 Jiwu Zhang Lijuan Zhu Jianqiang Du Bo Liu 《Neural Regeneration Research》 SCIE CAS CSCD 2007年第1期18-21,共4页
BACKGROUND: Literatures have reported that the density changes of dopamine transporter is negatively correlated with the severity degree and grading of disease condition of Parkinson disease (PD). However, the dist... BACKGROUND: Literatures have reported that the density changes of dopamine transporter is negatively correlated with the severity degree and grading of disease condition of Parkinson disease (PD). However, the distribution ofdopamine transporter in each nucleus of corpora striatum at each period is still unclear. OBJECTIVE: To observe the radioactive uptake distribution of dopamine transporter in bilateral corpora striata of patients with different stages of PD using single photon emission computed tomography (SPECT), and make a comparison with healthy controls. DESIGN: Case-control analysis. SETTING: Department of Imageology, Second Hospital Affiliated to Guangzhou University of Chinese Medicine. PARTICIPANTS: Thirty patients with PD admitted to Second Hospital Affiliated to Guangzhou University of Traditional Chinese Medicine between January and December 2005 were recruited. The involved patients, 19 male and 11 female, were aged from 36 to 80 years and with disease course of 2.5 months to 10 years. They all met the clinical diagnosis criteria of Britain Parkinson's disease Association Think Tank; Following Hoehn-Yahr grading: grade Ⅰ : unilateral morbidity; grade Ⅱ: bilateral morbidity, but without balance disorder; grade Ⅲ: bilateral morbidity, accompanied with early posture balance disorder; grade Ⅳ: severe morbidity, needs more help; grade V : without help, only in bed or wheelchair. There were 11 patients with mild PD (grade Ⅰ - Ⅱ ), 9 patients with moderate PD (grade Ⅲ) and 10 patients with advanced PD (grade Ⅳ - Ⅴ ). Meanwhile, 6 healthy persons were selected as normal controls. Informed consents were obtained from all the subjects. METHODS: Twenty-four hours after withdrawal of PD drugs, 30 patients with PD and 6 healthy controls took kalium perchloricum 400 mg orally. After lying down for 30 minutes, all the subjects were intravenously injected with 740 MBq 99Tc m-TRODAT-1 (Jiangsu Institute of Atomic Medicine, Batch No. 20040310) at elbow part. Following injection, image was collected using scanner for single photon emission computed tomography (ADAC Company, USA). Matrix was 64 × 64, each detecting head revolved 180 ° , 1 frame/60 s. Sixty-four frames were collected with double detecting heads, 50 K/frame. Faultages with clearest image of corpora striatum were selected. Regions of interest (ROI) of caudate nucleus, anterior and posterior putamen and thalamic region in bilateral corpora striata were radioactively counted, and mean value of radioactive counting of ROI was used as the mean value ofpixel in each region of bilateral corpora striata. MAIN OUTCOME MEASURES: Comparison of radioactive uptake in each region of brain between healthy persons and patients with PD. RESULTS: Thirty patients with PD and six healthy persons who received body examination participated in the final result. Comparison of radioactive uptake in each region between healthy persons and patients with PD: ①In the healthy persons, high-density radioactive uptake was found in bilateral corpora striata; Structures of caudate nucleus, anterior and posterior putamen, and thalamus were clear with eudipleural radioactive distribution, and the background of peripheral brain tissue was very low. ②Radioactive intakes in opposite anterior and posterior putamen of patients with mild PD were significantly inferior to those in homolateral ones(70.45±3.35, 87.64±2.65, t =15.82, P 〈 0.05). Structures of bilateral caudate nucleus and thalamus were clear with eudipleural radioactive distribution (P 〉 0.05). ③Radioactive intakes in anterior and posterior putamen and thalamus of patients with moderate PD were significantly reduced as compared with healthy persons. There were significant differences in mean radioactive counting of ROI between patients with PD and healthy persons (t =5.20, P 〈 0.05: t =3.95, P 〈 0.05); The structure of opposite caudate nucleus was not very clear, radioactive distribution of opposite caudate nucleus was significantly reduced as compared with homolateral one (81.11±4.25, 104.56±3.64, t = 14.65, P 〈 0.05). ④As for patients with advanced PD, the structure of bilateral corpora striata was not clear, radioactive intake was significantly reduced and peripheral background was heightened, even higher than the distribution of the whole corpora striatum. CONCLUSION: SPECT DAT imaging of brain can show the distribution of radioactive uptake in each region of bilateral corpora striata of patients with different stages of PD, which is helpful to diagnose and evaluate the severity of PD. 展开更多
关键词 Parkinson disease DOPAMINE tomography emission-computed single-photon
下载PDF
Rim^(18)F-fluorodeoxyglucose uptake of hepatic cavernous hemangioma on positron emission tomography/computed tomography:A case report
18
作者 Yong-An Hu Ya-Xin Guo Qi-Feng Huang 《World Journal of Clinical Cases》 SCIE 2024年第13期2243-2247,共5页
BACKGROUND Peripheral FDG accumulation in a hepatic hemangioma presenting in a patient with prolonged fever is rare.Therefore,clinicians should pay close attention to patients with hepatic mass.CASE SUMMARY A 54-year-... BACKGROUND Peripheral FDG accumulation in a hepatic hemangioma presenting in a patient with prolonged fever is rare.Therefore,clinicians should pay close attention to patients with hepatic mass.CASE SUMMARY A 54-year-old woman with a 4-wk history of daily fevers was admitted to our hospital.A whole body^(18)-Fluordesoxyglucose(PET-FDG)positron emission tomography/computed tomography(PET/CT)was performed to elucidate the source of the fever.However,whole body^(18)-FDG PET/CT raised the suspicion of a malignant lesion because of peripheral FDG accumulation(SUVmax 3.5 g/mL)higher than that of the normal liver parenchyma(SUVmax 1.6 g/mL)surrounding a hypoactive area,and no other abnormalities were showed.Subsequently,the patient underwent liver mass resection.Histopathology showed a hepatic cavernous hemangioma with fatty infiltration around the lesion.The fever disappeared four days after surgery and the patient did not present any complications during follow-up.CONCLUSION Fatty infiltration in the peripheral parts of hepatic cavernous hemangioma may lead to subacute inflammation which further activate the Kupffer cells.This may cause prolonged fever and peripheral rim FDG accumulation on PET/CT. 展开更多
关键词 ^(18)-Fluordesoxyglucose positron emission tomography/computed tomography Hepatocellular carcinoma FEVER Fatty infiltration Case report
下载PDF
Appearance of aseptic vascular grafts after endovascular aortic repair on[(18)F]fluorodeoxyglucose positron emission tomography/computed tomography
19
作者 Paige Bennett Maria Bernadette Tomas +2 位作者 Christopher F Koch Kenneth J Nichols Christopher J Palestro 《World Journal of Radiology》 2023年第8期241-249,共9页
BACKGROUND Diagnosis of prosthetic vascular graft infection with[(18)F]fluorodeoxyglucose positron emission tomography/computed tomography(18F-FDG PET/CT)allows for early detection of functional changes associated wit... BACKGROUND Diagnosis of prosthetic vascular graft infection with[(18)F]fluorodeoxyglucose positron emission tomography/computed tomography(18F-FDG PET/CT)allows for early detection of functional changes associated with infection,based on increased glucose utilization by activated macrophages and granulocytes.Aseptic vascular grafts,like all foreign bodies,can stimulate an inflammatory response,which can present as increased activity on 18F-FDG PET/CT.Consequently,distinguishing aseptic inflammation from graft infection,though important,can be difficult.In the case of endovascular aneurysm repair(EVAR),a minimally invasive procedure involving the transfemoral insertion of an endoprosthetic stent graft,the normal postoperative appearance of these grafts on 18F-FDG PET/CT can vary over time,potentially confounding study interpretation.AIM To investigate the visual,semiquantitative,and temporal characteristics of aseptic vascular grafts in patients status post EVAR.METHODS In this observational retrospective cohort study,patients with history of EVAR who underwent 18F-FDG PET/CT for indications other than infection were identified retrospectively.All patients were asymptomatic for graft infection-no abdominal pain,fever of unknown origin,sepsis,or leukocytosis-at the time of imaging and for≥2 mo after each PET/CT.Imaging studies such as CT for each patient were also reviewed,and any patients with suspected or confirmed vascular graft infection were excluded.One hundred two scans performed on 43 patients(34 males;9 females;age=77±8 years at the time of the final PET/CT)were retrospectively reviewed.All 43 patients had an abdominal aortic(AA)vascular graft,40 patients had a right iliac(RI)limb graft,and 41 patients had a left iliac(LI)limb graft.Twentytwo patients had 1 PET/CT and 21 patients had from 2 to 9 PET/CTs.Grafts were imaged between 2 mo to 168 mo(about 14 years)post placement.Eight grafts were imaged within 6 mo of placement,including three that were imaged within three months of placement.The mean interval between graft placement and PET/CT for all 102 scans was 51±39 mo.PET/CT data was reconstructed with region-of-interest analysis of proximal,mid and distal portions of the grafts and background ascending aorta.Maximum standardized uptake value(SUVmax)was recorded for each region.SUVmax-to-background uptake ratios(URs)were calculated.Visual assessment was performed using a 2-pattern grading scale:Diffuse(homogeneous uptake less than liver uptake)and focal(one or more areas of focal uptake in any part of the graft).Statistical analysis was performed.RESULTS In total,there were 306 AA grafts,285 LI grafts,282 RI grafts,and 306 ascending aorta background SUVmax measurements.For all 102 scans,mean SUVmax values for AA grafts were 2.8-3.0 along proximal,mid,and distal segments.Mean SUVmax values for LI grafts and RI grafts were 2.7-2.8.Mean SUVmax values for background were 2.5±0.5.Mean URs were 1.1-1.2.Visual analysis of the scans reflected results of quantitative analysis.On visual inspection,98%revealed diffuse,homogeneous 18F-FDG uptake less than liver.Graft URs and visual pattern categories were significantly associated for AA graft URs(F-ratio=21.5,P<0.001),LI graft URs(F-ratio=20.4,P<0.001),and RI graft URs(F-ratio=30.4,P<0.001).Thus,visual patterns of 18F-FDG uptake corresponded statistically significantly to semiquantitative URs.The age of grafts showing focal patterns was greater than grafts showing diffuse patterns,87±89 vs 50±37 mo,respectively(P=0.02).URs were significantly associated with graft age for AA grafts(r=0.19,P=0.001).URs were also significantly associated with graft age for LI grafts(r=0.25,P<0.0001),and RI grafts(r=0.31,P<0.001).Quartiles of similar numbers of graft(n=25-27)grouped by graft age indicated that URs were significantly higher for 4th quartile vs 2nd quartile URs(F-ratio=19.5,P<0.001).When evaluating URs,graft SUVmax values within 10%-20%of the ascending aorta SUVmax is evident in aseptic grafts,except for grafts in the oldest quartiles.In this study,grafts in the oldest quartiles(>7 years post EVAR)showed SUVmax up to 30%higher than the ascending aorta SUVmax.CONCLUSION Characteristics of an aseptic vascular stent graft in the aorta and iliac vessels on 18F-FDG PET/CT include graft SUVmax values within 10%-20%of the ascending aorta background SUVmax.The SUVmax of older aseptic grafts can be as much as 30%above background.The visual uptake pattern of diffuse,homogeneous uptake less than liver was seen in 98%of aseptic vascular grafts,making this pattern particularly reassuring for clinicians. 展开更多
关键词 Aseptic vascular grafts Endovascular aortic repair [(18)F]fluorodeoxyglucose positron emission tomography/computed tomography
下载PDF
Impact of random and scattered coincidences from outside of field of view on positron emission tomography/computed tomography imaging with different reconstruction protocols
20
作者 Mahak Osouli Alamdari Pardis Ghafarian +2 位作者 Arman Rahmim Mehrdad Bakhshayesh‑Karam Mohammad Reza Ay 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2023年第12期40-52,共13页
Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outsi... Image quality in positron emission tomography(PET)is affected by random and scattered coincidences and reconstruction protocols.In this study,we investigated the effects of scattered and random coincidences from outside the field of view(FOV)on PET image quality for different reconstruction protocols.Imaging was performed on the Discovery 690 PET/CT scanner,using experimental configurations including the NEMA phantom(a body phantom,with six spheres of different sizes)with a signal background ratio of 4:1.The NEMA phantom(phantom I)was scanned separately in a one-bed position.To simulate the effect of random and scatter coincidences from outside the FOV,six cylindrical phantoms with various diameters were added to the NEMA phantom(phantom II).The 18 emission datasets with mean intervals of 15 min were acquired(3 min/scan).The emission data were reconstructed using different techniques.The image quality parameters were evaluated by both phantoms.Variations in the signal-to-noise ratio(SNR)in a 28-mm(10-mm)sphere of phantom II were 37.9%(86.5%)for ordered-subset expectation maximization(OSEM-only),36.8%(81.5%)for point spread function(PSF),32.7%(80.7%)for time of flight(TOF),and 31.5%(77.8%)for OSEM+PSF+TOF,respectively,indicating that OSEM+PSF+TOF reconstruction had the lowest noise levels and lowest coefficient of variation(COV)values.Random and scatter coincidences from outside the FOV induced lower SNR,lower contrast,and higher COV values,indicating image deterioration and significantly impacting smaller sphere sizes.Amongst reconstruction protocols,OSEM+PSF+TOF and OSEM+PSF showed higher contrast values for sphere sizes of 22,28,and 37 mm and higher contrast recovery coefficient values for smaller sphere sizes of 10 and 13 mm. 展开更多
关键词 Positron emission tomography/computed tomography(PET/CT) Random coincidences Scatter coincidences·Time of flight(TOF) Point spread function(PSF) Field of view(FOV) Noise equivalent count rate(NECR) Signal-toNoise ratio(SNR)
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部