期刊文献+
共找到220篇文章
< 1 2 11 >
每页显示 20 50 100
Use of high-resolution X-ray computed tomography and 3D image analysis to quantify mineral dissemination and pore space in oxide copper ore particles 被引量:7
1
作者 Bao-hua Yang Ai-xiang Wu +2 位作者 Guillermo A.Narsilio Xiu-xiu Miao Shu-yue Wu 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2017年第9期965-973,共9页
Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance. To quantify the mineral dissemination and pore space distribution of an ore particle,... Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance. To quantify the mineral dissemination and pore space distribution of an ore particle, a cylindrical copper oxide ore sample (I center dot 4.6 mm x 5.6 mm) was scanned using high-resolution X-ray computed tomography (HRXCT), a nondestructive imaging technology, at a spatial resolution of 4.85 mu m. Combined with three-dimensional (3D) image analysis techniques, the main mineral phases and pore space were segmented and the volume fraction of each phase was calculated. In addition, the mass fraction of each mineral phase was estimated and the result was validated with that obtained using traditional techniques. Furthermore, the pore phase features, including the pore size distribution, pore surface area, pore fractal dimension, pore centerline, and the pore connectivity, were investigated quantitatively. The pore space analysis results indicate that the pore size distribution closely fits a log-normal distribution and that the pore space morphology is complicated, with a large surface area and low connectivity. This study demonstrates that the combination of HRXCT and 3D image analysis is an effective tool for acquiring 3D mineralogical and pore structural data. 展开更多
关键词 high-resolution x-ray computed tomography 3D image analysis ore particles mineral dissemination pore space
下载PDF
Microstructure Evolution of Sandstone Cemented by Microbe Cement Using X-ray Computed Tomography 被引量:4
2
作者 RONG Hui QIAN Chunxiang 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2013年第6期1134-1139,共6页
The bio-sandstone, which was cemented by microbe cement, was firstly prepared, and then the microstructure evolution process was studied by X-ray computed tomography (X-CT) technique. The experimental results indica... The bio-sandstone, which was cemented by microbe cement, was firstly prepared, and then the microstructure evolution process was studied by X-ray computed tomography (X-CT) technique. The experimental results indicate that the microstructure of bio-sandstone becomes dense with the development of age. The evolution of inner structure at different positions is different due to the different contents of microbial induced precipitation calcite. Besides, the increase rate of microbial induced precipitation calcite gradually decreases because of the reduction of microbe absorption content with the decreasing pore size in bio-sandstone. 展开更多
关键词 microbe cement bio-sandstone microstructure evolution x-ray computed tomography CALCITE
下载PDF
Kernel crack characteristics for X-ray computed microtomography(μCT)and their relationship with the breakage rate of maize varieties 被引量:2
3
作者 DONG Peng-fei XIE Rui-zhi +6 位作者 WANG Ke-ru MING Bo HOU Peng HOU Jun-feng XUE Jun LI Chao-hai LI Shao-kun 《Journal of Integrative Agriculture》 SCIE CAS CSCD 2020年第11期2680-2689,共10页
The most significant problem of maize grain mechanical harvesting quality in China at present is the high grain breakage rate(BR).BR is often the key characteristic that is measured to select hybrids desirable for mec... The most significant problem of maize grain mechanical harvesting quality in China at present is the high grain breakage rate(BR).BR is often the key characteristic that is measured to select hybrids desirable for mechanical grain harvesting.However,conventional BR evaluation and measurement methods have challenges and limitations.Microstructural crack parameters evaluation of maize kernel is of great importance to BR.In this connection,X-ray computed microtomography(μ-CT)has proven to be a quite useful method for the assessment of microstructure,as it provides important microstructural parameters,such as object volume,surface,surface/volume ratio,number of closed pores,and others.X-ray computed microtomography is a non-destructive technique that enables the reuse of samples already measured and also yields bidimensional(2D)cross-sectional images of the sample as well as volume rendering.In this paper,six different maize hybrid genotypes are used as materials,and the BR of the maize kernels of each variety is tested in the field mechanical grain harvesting,and the BR is used as an index for evaluating the breakage resistance of the variety.The crack characteristic parameters of kernel were detected by X-ray micro-computed tomography,and the relationship between the BR and the kernel crack characteristics was analyzed by stepwise regression analysis.Establishing a relationship between crack characteristic parameters and BR of maize is vital for judging breakage resistance.The results of stepwise multiple linear regression(MLR)showed that the crack characteristics of the object surface,number of closed pores,surface of closed pores,and closed porosity percent were significantly correlated to the BR of field mechanical grain harvesting,with the standard partial regression coefficients of–0.998,–0.988,–0.999,and–0.998,respectively.The R2 of this model was 0.999.Results validation showed that the Stepwise MLR Model could well predict the BR of maize based on these four variables. 展开更多
关键词 breakage rate kernel crack MAIZE MICROSTRUCTURE x-ray computed microtomography
下载PDF
In situ compression and X-ray computed tomography of flow battery electrodes 被引量:1
4
作者 Rhodri Jervis Matt D.R.Kok +6 位作者 Tobias P.Neville Quentin Meyer Leon D.Brown Francesco Iacoviello Jeff T.Gostick Dan J.L.Brett Paul R.Shearing 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2018年第5期1353-1361,共9页
Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised... Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised due to cost and performance issues, many of which are linked to the microstructure of the porous carbon electrodes used. Here, for the first time, we offer a detailed study of the in situ effects of compression on a commercially available carbon felt electrode. Visualisation of electrode structure us- ing X-ray computed tomography shows the non-linear way that these materials compress and various metrics are used to elucidate the changes in porosity, pore size distribution and tortuosity factor under compressions from 0%-90%. 展开更多
关键词 Redox flow battery x-ray computed tomography Compression Carbon felt RFB
下载PDF
Distinct root system acclimation patterns of seagrass Zostera japonica in sediments of different trophic status:a research by X-ray computed tomography
5
作者 Xiaoyue SONG Yi ZHOU +7 位作者 Jiangning ZENG Lu SHOU Xiaomei ZHANG Shidong YUE Wei GAO Weihua FENG Zhifu WANG Ping DU 《Journal of Oceanology and Limnology》 SCIE CAS CSCD 2021年第6期2267-2280,共14页
Conspecific seagrass living in differing environments may develop different root system acclimation patterns.We applied X-ray computed tomography(CT)for imaging and quantifying roots systems of Zostera japonica collec... Conspecific seagrass living in differing environments may develop different root system acclimation patterns.We applied X-ray computed tomography(CT)for imaging and quantifying roots systems of Zostera japonica collected from typical oligotrophic and eutrophic sediments in two coastal sites of northern China,and determined sediment physicochemical properties that might influence root system morphology,density,and distribution.The trophic status of sediments had little influence on the Z.japonica root length,and diameters of root and rhizome.However,Z.japonica in oligotrophic sediment developed the root system with longer rhizome node,deeper rhizome distribution,and larger allocation to below-ground tissues in order to acquire more nutrients and relieve the N deficiency.And the lower root and rhizome densities of Z.japonica in eutrophic sediment were mainly caused by fewer shoots and shorter longevity,which was resulted from the more serious sulfide inhibition.Our results systematically revealed the effect of sediment trophic status on the phenotypic plasticity,quantity,and distribution of Z.japonica root system,and demonstrated the feasibly of X-ray CT in seagrass root system research. 展开更多
关键词 Zostera japonica root system acclimation pattern SEDIMENT trophic status x-ray computed tomography
下载PDF
X-ray Computed Tomography Characterization of 3D Tufted Twill Textile Composite for Aerostructures
6
作者 A.Saboktakin M.Shahrouz +1 位作者 T.Vu-Khanh J.Bicerano 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2019年第3期7-13,共7页
Damage assessments in three dimensional (3D) textile composites subjected to mechanical loading can be performed by non-destructive and destructive techniques.This paper applies the two techniques to investigate the f... Damage assessments in three dimensional (3D) textile composites subjected to mechanical loading can be performed by non-destructive and destructive techniques.This paper applies the two techniques to investigate the fracture behavior of 3D tufted textile composites.X-ray computed tomography as a non-destructive evaluation method is appropriate to detect damage locations and identify their progression in 3D textile composites.Destructive methods such as sectioning toward observing damage provide valuable information about damage patterns.The results of this research could be utilized to evaluate the initial cause of rupture in 3D tufted composites used in aerospace structures and analyze fracture modes and damage progression. 展开更多
关键词 x-ray computed TOMOGRAPHY DAMAGE CHARACTERIZATION 3D composite TEXTILE PREFORM
下载PDF
X-Ray Computed Tomography for Root Quantification
7
作者 Bente Foereid 《Open Journal of Soil Science》 2015年第7期145-148,共4页
Soil cores from a field growing barley and barley mutants without root hairs under conventional and minimum tillage were sampled. They were X-ray scanned to produce a 3D image and then the roots were washed out and we... Soil cores from a field growing barley and barley mutants without root hairs under conventional and minimum tillage were sampled. They were X-ray scanned to produce a 3D image and then the roots were washed out and weight and length were determined by conventional means. Root volume and surface area were then calculated from the 3D images using state of the art software and methodology, and the measured and calculated measures were correlated. The only strong and significant correlation was between measured weight and calculated volume for mutants without root hairs. It is concluded that the software cannot segment out very small roots, but segmentation accuracy also depends on root structure in some unknown way. Any study using X-ray computed tomography to quantify roots as they grow in situ should start with a calibration for the conditions in question. 展开更多
关键词 ROOTS 3D IMAGE x-ray computed TOMOGRAPHY
下载PDF
Experimental Investigation and X-Ray Computed Microtomography Simulation on Thermal Physical Properties of Foundation Materials after Molten Salt Leakage in the Storage Tank
8
作者 WANG Zhaowen ZHOU Hao +3 位作者 LUO Jiawei LI Yawei FANG Hao LIU Tianxiao 《Journal of Thermal Science》 SCIE EI CAS CSCD 2024年第2期591-601,共11页
This paper studied the thermal physical properties of foundation materials in the molten salt tank of thermal energy storage system after molten salt leakage by Transient plane source experiment and X-ray computed mic... This paper studied the thermal physical properties of foundation materials in the molten salt tank of thermal energy storage system after molten salt leakage by Transient plane source experiment and X-ray computed microtomography simulation methods.The microstructure,thermal properties and pressure resistance with different particle diameters were addressed.The measured heat conductivities from Transient plane source experiment for three cases are 0.49 W/(m·K),0.48 W/(m·K),and 0.51 W/(m·K),and the porosity is 30.1%,30.7%,and 31.2% respectively.The heat conductivity simulating results of three cases are 0.471 W/(m·K),0.482W/(m·K),and 0.513 W/(m·K).The ratio of difference between the results of simulation and Transient plane source measurement is as low as 1.2%,verifying the reliability of experimental and simulation results to a certain degree.Compared with the heat conductivity of 0.097-0.129 W/(m·K) and porosity of 71.6%-78.9% without leaking salt,the porosity is reduced by more than 50% while the heat conductivity increased by 4 to 5 times after molten salt leakage.This significant increase in heat conductivity has a great impact on security operation,structure design,and modeling of the tank foundation for solar power plants. 展开更多
关键词 heat conductivity x-ray computed microtomography foundation materials three-phase threshold algorithm molten salt leakage
原文传递
Computed tomography-based nomogram of Siewert type Ⅱ/Ⅲ adenocarcinoma of esophagogastric junction to predict response to docetaxel, oxaliplatin and S-1
9
作者 Chuan-Qinyuan Zhou Dan Gao +7 位作者 Yan Gui Ning-Pu Li Wen-Wen Guo Hai-Ying Zhou Rui Li Jing Chen Xiao-Ming Zhang Tian-Wu Chen 《World Journal of Radiology》 2024年第1期9-19,共11页
BACKGROUND Neoadjuvant chemotherapy(NAC)has become the standard care for advanced adenocarcinoma of esophagogastric junction(AEG),although a part of the patients cannot benefit from NAC.There are no models based on ba... BACKGROUND Neoadjuvant chemotherapy(NAC)has become the standard care for advanced adenocarcinoma of esophagogastric junction(AEG),although a part of the patients cannot benefit from NAC.There are no models based on baseline computed tomography(CT)to predict response of Siewert type II or III AEG to NAC with docetaxel,oxaliplatin and S-1(DOS).AIM To develop a CT-based nomogram to predict response of Siewert type II/III AEG to NAC with DOS.METHODS One hundred and twenty-eight consecutive patients with confirmed Siewert type II/III AEG underwent CT before and after three cycles of NAC with DOS,and were randomly and consecutively assigned to the training cohort(TC)(n=94)and the validation cohort(VC)(n=34).Therapeutic effect was assessed by disease-control rate and progressive disease according to the Response Evaluation Criteria in Solid Tumors(version 1.1)criteria.Possible prognostic factors associated with responses after DOS treatment including Siewert classification,gross tumor volume(GTV),and cT and cN stages were evaluated using pretherapeutic CT data in addition to sex and age.Univariate and multivariate analyses of CT and clinical features in the TC were performed to determine independent factors associated with response to DOS.A nomogram was established based on independent factors to predict the response.The predictive performance of the nomogram was evaluated by Concordance index(C-index),calibration and receiver operating characteristics curve in the TC and VC.RESULTS Univariate analysis showed that Siewert type(52/55 vs 29/39,P=0.005),pretherapeutic cT stage(57/62 vs 24/32,P=0.028),GTV(47.3±27.4 vs 73.2±54.3,P=0.040)were significantly associated with response to DOS in the TC.Multivariate analysis of the TC also showed that the pretherapeutic cT stage,GTV and Siewert type were independent predictive factors related to response to DOS(odds ratio=4.631,1.027 and 7.639,respectively;all P<0.05).The nomogram developed with these independent factors showed an excellent performance to predict response to DOS in the TC and VC(C-index:0.838 and 0.824),with area under the receiver operating characteristic curve of 0.838 and 0.824,respectively.The calibration curves showed that the practical and predicted response to DOS effectively coincided.CONCLUSION A novel nomogram developed with pretherapeutic cT stage,GTV and Siewert type predicted the response of Siewert type II/III AEG to NAC with DOS. 展开更多
关键词 Esophagogastric junction ADENOCARCINOMA Neoadjuvant chemotherapy RESPONSE Tomography x-ray computed Predictor
下载PDF
Seeing through Materials:X-Ray Imaging Using Computed Tomography
10
作者 Yisheng Miao Chengpeng Xue +2 位作者 Xuelong Wu Zhongyao Li Junsheng Wang 《Journal of Beijing Institute of Technology》 EI CAS 2023年第4期494-516,共23页
X-ray computed tomography(XCT)has recently emerged as a powerful tool for characterizing the evolution of microstructure during phase transformation in three dimensional(3D)such as dendritic solidification of alloys.T... X-ray computed tomography(XCT)has recently emerged as a powerful tool for characterizing the evolution of microstructure during phase transformation in three dimensional(3D)such as dendritic solidification of alloys.This paper briefly reviews the recent advances in the in-situ observation of aluminium alloys,magnesium alloys and nickel-based superalloys during solidification using laboratory XCT and synchrotron X-ray sources.The focus is on the growth kinetics of dendrites,porosity and secondary phases.In addition,in-situ characterization during the loading and corrosion process is also discussed. 展开更多
关键词 x-ray computed tomography(XCT) SYNCHROTRON DENDRITE POROSITY ALLOYS
下载PDF
Importance of computed tomography in posterior malleolar fractures:Added information to preoperative X-ray studies
11
作者 NoéDe Marchi Neto Pietro Felice Tomazini Nesello +3 位作者 Jordanna Maria Bergamasco Marco Tulio Costa Ralph Walter Christian Nilson Roberto Severino 《World Journal of Orthopedics》 2023年第12期868-877,共10页
BACKGROUND Ankle fractures are common lesions of the lower limbs.Approximately 40%of ankle fractures affect the posterior malleolus(PM).Historically,PM osteosynthesis was recommended when PM size in X-ray images was g... BACKGROUND Ankle fractures are common lesions of the lower limbs.Approximately 40%of ankle fractures affect the posterior malleolus(PM).Historically,PM osteosynthesis was recommended when PM size in X-ray images was greater than 25%of the joint.Currently,computed tomography(CT)has been gaining traction in the preoperative evaluation of ankle fractures.AIM To elucidate the similarity in dimensions and to correlate PM size in X-ray images with the articular surface of the affected tibial plafond in the axial view on CT(AXCT)of a PM fracture.METHODS Eighty-one patients(mean age:39.4±13.5 years)were evaluated(54.3%were male).Two independent examiners measured PM size in profile X-ray images(PMXR)and sagittal CT(SAGCT)slices.The correlation of the measurements between the examiners and the difference in the PM fragment sizes between the two images were compared.Next,the PM size in PMXR was compared with the surface of the tibial plafond involved in the fracture in AXCT according to the Haraguchi classification.RESULTS The correlation rates between the examiners were 0.93 and 0.94 for PMXR and SAGCT,respectively(P<0.001).Fragments were 2.12%larger in SAGCT than in PMXR(P=0.018).In PMXR,there were 56 cases<25%and 25 cases≥25%.When PMXR was<25%,AXCT corresponded to 10.13%of the tibial plafond.When PMXR was≥25%,AXCT was 24.52%(P<0.001).According to the Haraguchi classification,fracture types I and II had similar PMXR measurements that were greater than those of type III.When analyzing AXCT,a significant difference was found between the three types,with II>I>III(P<0.001).CONCLUSION PM fractures show different sizes using X-ray or CT images.CT showed a larger PM in the sagittal plane and allowed the visualization of the real dimensions of the tibial plafond surface. 展开更多
关键词 Ankle fracture Posterior malleolar fracture computed tomography x-ray Posterior malleolus fracture Trimalleolar facture
下载PDF
Can visceral fat parameters based on computed tomography be used to predict occult peritoneal metastasis in gastric cancer? 被引量:3
12
作者 Li-Ming Li Lei-Yu Feng +4 位作者 Chen-Chen Liu Wen-Peng Huang Yang Yu Peng-Yun Cheng Jian-Bo Gao 《World Journal of Gastroenterology》 SCIE CAS 2023年第15期2310-2321,共12页
BACKGROUND The preoperative prediction of peritoneal metastasis(PM)in gastric cancer would prevent unnecessary surgery and promptly indicate an appropriate treatment plan.AIM To explore the predictive value of viscera... BACKGROUND The preoperative prediction of peritoneal metastasis(PM)in gastric cancer would prevent unnecessary surgery and promptly indicate an appropriate treatment plan.AIM To explore the predictive value of visceral fat(VF)parameters obtained from preoperative computed tomography(CT)images for occult PM and to develop an individualized model for predicting occult PM in patients with gastric carcinoma(GC).METHODS A total of 128 confirmed GC cases(84 male and 44 female patients)that underwent CT scans were analyzed and categorized into PM-positive(n=43)and PM-negative(n=85)groups.The clinical characteristics and VF parameters of two regions of interest(ROIs)were collected.Univariate and stratified analyses based on VF volume were performed to screen for predictive characteristics for occult PM.Prediction models with and without VF parameters were established by multivariable logistic regression analysis.RESULTS The mean attenuations of VF_(ROI 1)and VF_(ROI 2)varied significantly between the PM-positive and PMnegative groups(P=0.044 and 0.001,respectively).The areas under the receiver operating characteristic curves(AUCs)of VF_(ROI 1)and VF_(ROI 2)were 0.599 and 0.657,respectively.The mean attenuation of VF_(ROI 2)was included in the final prediction combined model,but not an independent risk factor of PM(P=0.068).No significant difference was observed between the models with and without mean attenuation of VF(AUC:0.749 vs 0.730,P=0.339).CONCLUSION The mean attenuation of VF is a potential auxiliary parameter for predicting occult PM in patients with GC. 展开更多
关键词 Gastric carcinoma Peritoneal metastasis Visceral fat Tomography x-ray computed Prediction Individualized model
下载PDF
Pancreatic neuroendocrine tumor detected by technetium-99m methoxy-2-isobutylisonitrile single photon emission computed tomography/computed tomography:A case report
13
作者 Chang-Jiang Liu Hua-Jun Yang +1 位作者 Yan-Chun Peng De-Yu Huang 《World Journal of Clinical Cases》 SCIE 2023年第12期2825-2831,共7页
BACKGROUND Pancreatic neuroendocrine tumors(NETs)account for about 1%–2%of pancreatic tumors and about 8%of all NETs.Computed tomography(CT),magnetic resonance imaging,and endoscopic ultrasound are common imaging mod... BACKGROUND Pancreatic neuroendocrine tumors(NETs)account for about 1%–2%of pancreatic tumors and about 8%of all NETs.Computed tomography(CT),magnetic resonance imaging,and endoscopic ultrasound are common imaging modalities for the diagnosis of pancreatic NETs.Furthermore,somatostatin receptor imaging is of great value for diagnosing pancreatic NETs.Herein,we report the efficacy of technetium-99m methoxy-2-isobutylisonitrile(99mTc-MIBI)single photon emission CT(SPECT)/CT for detecting pancreatic NETs.CASE SUMMARY A 57-year-old woman presented to our hospital with a 1-d history of persistent upper abdominal distending pain.The distending pain in the upper abdomen was aggravated after eating,with nausea and retching.Routine blood test results showed a high neutrophil percentage,low leukomonocyte and monocyte percentages,and low leukomonocyte and eosinophil counts.Amylase,liver and kidney function,and tumor markers alpha-fetoprotein,carcinoembryonic antigen,and cancer antigen(CA)125,CA72-4,CA19-9,and CA153 were normal.Abdominal CT showed a mass,with multiple calcifications between the pancreas and the spleen.The boundary between the mass and the pancreas and spleen was poorly defined.Contrast-enhanced CT revealed that the upper abdominal mass was unevenly and gradually enhanced.99mTc-MIBI SPECT/CT revealed that a focal radioactive concentration,with mild radioactive concentration extending into the upper abdominal mass,was present at the pancreatic body and tail.The 99mTc-MIBI SPECT/CT manifestations were consistent with the final pathological diagnosis of pancreatic NET.CONCLUSION 99mTc-MIBI SPECT/CT appears to be a valuable tool for detecting pancreatic NETs. 展开更多
关键词 Neuroendocrine tumors PANCREAS Tc-99m-Methoxy-2-isobutylisonitrile Single photon emission computed tomography x-ray computed tomography Case report
下载PDF
Non-destructive 3D geometric modeling of maize root-stubble in-situ via X-ray computed tomography 被引量:1
14
作者 Xu Zhao Luyu Xing +2 位作者 Shifan Shen Jiaming Liu Daixing Zhang 《International Journal of Agricultural and Biological Engineering》 SCIE EI CAS 2020年第3期174-179,共6页
No-tillage seeding has become an important approach to improve crop productivity,which needs colters of high performance to cut the root-stubble-soil composite.However,the difficulty of maize root-stubbles three-dimen... No-tillage seeding has become an important approach to improve crop productivity,which needs colters of high performance to cut the root-stubble-soil composite.However,the difficulty of maize root-stubbles three-dimensional(3D)modeling hinders finite element(FE)simulation to improve development efficiency of such colters because of maize root system complexity and opaque nature of the soil.Fortunately,the non-destructive 3D geometric model of the maize root-stubble in-situ can be established via X-ray computed tomography(CT)following by a systematic procedure.The whole procedure includes CT scanning of the maize root-stubble-soil composite sample,image reconstruction via filtered back-projection(FBP)with the Hanning filter,segmentation of root-stubble via a variational level set method,and post-processing via morphological operations.The 3D reconstruction model of the maize root-stubble in-situ presents a complete,complex and in-situ geometrical morphology,which cannot be realized via other methods,including the destructive modelling after washing via CT.This study is the first to build a 3D geometric model of a maize root-stubble in-situ via CT,which opens up new possibilities for simulation of root-stubble-soil cutting using FEM,and much other research related to plant root-stubbles. 展开更多
关键词 maize root-stubble non-destructive modeling x-ray computed tomography variational level set method
原文传递
Digital microstructure insights to phase evolution and thermal flow properties of hydrates by X-ray computed tomography 被引量:1
15
作者 ZHAO Zhi ZHOU XiaoPing 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2021年第1期187-202,共16页
Natural gas-hydrates are valuable energy resource with rich deposits,and their thermal transport and thermal dynamic mechanical behaviors significantly affect the long-term production process and phase change-based th... Natural gas-hydrates are valuable energy resource with rich deposits,and their thermal transport and thermal dynamic mechanical behaviors significantly affect the long-term production process and phase change-based thermal energy storage characteristics of these energy resources.This paper aims to propose novel relations to predict the thermophysical properties,to investigate the hydrate phase evolution in microstructures,and to study the thermal transport and thermal dynamic mechanical properties.Hydrates formation experiments in sandpack samples and ultrasonic wave tests are conducted with the aid of X-ray CT imaging.Digitalization microstructures models and variables are defined to describe the hydrate phase evolution,and novel relations are proposed to accurately predict the thermophysical properties based on the microporosity and ultrasonic wave velocities.The thermal transport and thermal dynamic mechanical properties in microstructures with hydrate,water,residuary pore and grain phases are studied.Results show that the average errors of porosity,P-wave and S-wave velocities between the experimental data and computed results by the proposed relations are less than 5%,indicating the accuracy and reliability of the proposed method.The temperature fraction decreases with increasing underground temperature and decreasing hydrate saturation.The thermal stress and thermal displacement increase as temperature and hydrate saturation increase.There are strong anisotropy for the temperature fraction,thermal stress and thermal displacement during the thermal transport of hydrates. 展开更多
关键词 x-ray computed tomography imaging hydrate phase evolution transport properties effective thermal conductivity thermal-mechanical properties
原文传递
Assessing efficacy of standard impregnation techniques on die-cast aluminum alloys using X-ray micro-CT
16
作者 Ajith Bandara Koichi Kan +3 位作者 Katanaga Yusuke Natsuto Soga Akifumi Koike Toru Aoki 《China Foundry》 SCIE EI CAS CSCD 2024年第3期276-286,共11页
Utilizing lightweight Al alloys in various industrial applications requires achieving precise pressure tightness and leak requirements.Vacuum pressure impregnation(VPI)with thermosetting polymers is commonly used to a... Utilizing lightweight Al alloys in various industrial applications requires achieving precise pressure tightness and leak requirements.Vacuum pressure impregnation(VPI)with thermosetting polymers is commonly used to address leakage defects in die-cast Al alloys.In this study,the efficacy of the VPI technique in sealing alloy parts was investigated using a combination of nondestructive micro X-ray computed tomography(micro XCT)and a standard leak test.The results demonstrate that the commonly used water leak test is insufficient for determining the sealing performance.Instead,micro XCT shows distinct advantages by enabling more comprehensive analysis.It reveals the presence of a low atomic number impregnates sealant within casting defects,which has low grey contrast and allows for visualizing primary leakage paths in 3D.The effective atomic number of impregnated resin is 6.75 and that of Al alloy is 13.69 by dual-energy X-ray CT.This research findings will contribute to enhancing the standard VPI process parameters and the properties of impregnating sealants to improve quality assurance for impregnation in industrial metals. 展开更多
关键词 nondestructive testing Al alloy die-casting vacuum pressure impregnation micro x-ray computed tomography duel-energy x-ray CT
下载PDF
Isotropic compression behavior of granular assembly with non-spherical particles by X-ray micro-computed tomography and discrete element modeling
17
作者 Nan Zhang Ahmadreza Hedayat +4 位作者 Shaoyang Han Runlin Yang Héctor Gelber Bolaños Sosa Juan JoséGonzález Cárdenas Guido Edgard SalasÁlvarez 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2021年第5期972-984,共13页
The particle morphological properties,such as sphericity,concavity and convexity,of a granular assembly significantly affect its macroscopic and microscopic compressive behaviors under isotropic loading condition.Howe... The particle morphological properties,such as sphericity,concavity and convexity,of a granular assembly significantly affect its macroscopic and microscopic compressive behaviors under isotropic loading condition.However,limited studies on investigating the microscopic behavior of the granular assembly with real particle shapes under isotropic compression were reported.In this study,X-ray computed tomography(mCT)and discrete element modeling(DEM)were utilized to investigate isotropic compression behavior of the granular assembly with regard to the particle morphological properties,such as particle sphericity,concavity and interparticle frictions.The mCT was first used to extract the particle morphological parameters and then the DEM was utilized to numerically investigate the influences of the particle morphological properties on the isotropic compression behavior.The image reconstruction from mCT images indicated that the presented particle quantification algorithm was robust,and the presented microscopic analysis via the DEM simulation demonstrated that the particle surface concavity significantly affected the isotropic compression behavior.The observations of the particle connectivity and local void ratio distribution also provided insights into the granular assembly under isotropic compression.Results found that the particle concavity and interparticle friction influenced the most of the isotropic compression behavior of the granular assemblies. 展开更多
关键词 x-ray computed tomography(mCT) Discrete element modeling(DEM) Isotropic compression Particle surface curvature Particle morphology
下载PDF
Advanced characterization of pores and fractures in coals by nuclear magnetic resonance and X-ray computed tomography 被引量:62
18
作者 YAO YanBin, LIU DaMeng, CAI YiDong & LI JunQian School of Energy Resources, China University of Geosciences, Beijing 100083, China 《Science China Earth Sciences》 SCIE EI CAS 2010年第6期854-862,共9页
This paper demonstrates capabilities of low-field nuclear magnetic resonance (NMR) and microfocus X-ray computed tomography (μCT) in advanced, nondestructive, and quantitative characterization of pore types, producib... This paper demonstrates capabilities of low-field nuclear magnetic resonance (NMR) and microfocus X-ray computed tomography (μCT) in advanced, nondestructive, and quantitative characterization of pore types, producible porosity, pore structure, and spatial disposition of pore-fractures in coals. Results show that the NMR transverse relaxation time (T2) at 0.5–2.5, 20–50, and >100 ms correspond to pores of <0.1 μm, >0.1 μm, and fractures, respectively. A much higher T2 spectrum peak reflects a much better development of pores (or fractures) corresponding to the T2, and vice versa. Three basic components in coals, i.e., the pores (or fractures), coal matrix, and minerals have their distinctive range of CT numbers. Among these, the CT number of pores is commonly less than 600 HU. The producible porosity, which is a determination of permeability, can be calculated by T2 cutoff value (T2C) of coal NMR. The coal pore structure can be efficiently estimated by the newly proposed "T2C based model". Finally, μCT scan was proven capable of modeling and spatial visualization of pores and fractures. 展开更多
关键词 coalbed METHANE PORE fracture nuclear magnetic resonance (NMR) x-ray computed tomography (X-CT)
原文传递
Effects of dry-wet cycles on three-dimensional pore structure and permeability characteristics of granite residual soil using X-ray micro computed tomography 被引量:11
19
作者 Ran An Lingwei Kong +1 位作者 Xianwei Zhang Chengsheng Li 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2022年第3期851-860,共10页
Due to seasonal climate alterations,the microstructure and permeability of granite residual soil are easily affected by multiple dry-wet cycles.The X-ray micro computed tomography(micro-CT)acted as a nondestructive to... Due to seasonal climate alterations,the microstructure and permeability of granite residual soil are easily affected by multiple dry-wet cycles.The X-ray micro computed tomography(micro-CT)acted as a nondestructive tool for characterizing the microstructure of soil samples exposed to a range of damage levels induced by dry-wet cycles.Subsequently,the variations of pore distribution and permeability due to drywet cycling effects were revealed based on three-dimensional(3D)pore distribution analysis and seepage simulations.According to the results,granite residual soils could be separated into four different components,namely,pores,clay,quartz,and hematite,from micro-CT images.The reconstructed 3D pore models dynamically demonstrated the expanding and connecting patterns of pore structures during drywet cycles.The values of porosity and connectivity are positively correlated with the number of dry-wet cycles,which were expressed by exponential and linear functions,respectively.The pore volume probability distribution curves of granite residual soil coincide with the χ^(2)distribution curve,which verifies the effectiveness of the assumption of χ^(2)distribution probability.The pore volume distribution curves suggest that the pores in soils were divided into four types based on their volumes,i.e.micropores,mesopores,macropores,and cracks.From a quantitative and visual perspective,considerable small pores are gradually transformed into cracks with a large volume and a high connectivity.Under the action of dry-wet cycles,the number of seepage flow streamlines which contribute to water permeation in seepage simulation increases distinctly,as well as the permeability and hydraulic conductivity.The calculated hydraulic conductivity is comparable with measured ones with an acceptable error margin in general,verifying the accuracy of seepage simulations based on micro-CT results. 展开更多
关键词 Granite residual soil Dry-wet cycle x-ray micro computed tomography(micro-CT) Three-dimensional(3D)pore distribution Seepage simulations PERMEABILITY
下载PDF
Using X-ray computed tomography and micro-Raman spectrometry to measure individual particle surface area, volume, and morphology towards investigating atmospheric heterogeneous reactions 被引量:1
20
作者 Mingjin Wang Nan Zheng +6 位作者 Tong Zhu Jing Shang Ting Yu Xiaojuan Song Defeng Zhao Yong Guan Yangchao Tian 《Journal of Environmental Sciences》 SCIE EI CAS CSCD 2018年第7期23-32,共10页
Heterogeneous reactions on the aerosol particle surface in the atmosphere play important roles in air pollution, climate change, and global biogeochemical cycles. However, the reported uptake coefficients of heterogen... Heterogeneous reactions on the aerosol particle surface in the atmosphere play important roles in air pollution, climate change, and global biogeochemical cycles. However, the reported uptake coefficients of heterogeneous reactions usually have large variations and may not be relevant to real atmospheric conditions. One of the major reasons for this is the use of bulk samples in laboratory experiments, while particles in the atmosphere are suspended individually. A number of technologies have been developed recently to study heterogeneous reactions on the surfaces of individual particles. Precise measurements on the reactive surface area, volume, and morphology of individual particles are necessary for calculating the uptake coefficient, quantifying reactants and products, and understanding the reaction mechanism better. In this study, for the first time we used synchrotron radiation X-ray computed tomography(XCT) and micro-Raman spectrometry to measure individual CaCO_3 particle morphology, with sizes ranging from 3.5–6.5 μm. Particle surface area and volume were calculated using a reconstruction method based on software threedimensional(3-D) rendering. The XCT was first validated with high-resolution fieldemission scanning electron microscopy(FE-SEM) to acquire accurate CaCO_3 particle surface area and volume estimates. Our results showed an average difference of only 6.1% in surface area and 3.2% in volume measured either by micro-Raman spectrometry or X-ray tomography. X-ray tomography and FE-SEM can provide more morphological details of individual Ca CO3 particles than micro-Raman spectrometry. This study demonstrated that X-ray computed tomography and micro-Raman spectrometry can precisely measure the surface area, volume, and morphology of an individual particle. 展开更多
关键词 Heterogeneous reactions Individual CaCO3 particle Micro-Raman spectrometry Synchrotron radiation x-ray computed tomography MORPHOLOGY Surface area VOLUME
原文传递
上一页 1 2 11 下一页 到第