期刊文献+
共找到325篇文章
< 1 2 17 >
每页显示 20 50 100
A machine learning-based strategy for predicting the mechanical strength of coral reef limestone using X-ray computed tomography
1
作者 Kai Wu Qingshan Meng +4 位作者 Ruoxin Li Le Luo Qin Ke ChiWang Chenghao Ma 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第7期2790-2800,共11页
Different sedimentary zones in coral reefs lead to significant anisotropy in the pore structure of coral reef limestone(CRL),making it difficult to study mechanical behaviors.With X-ray computed tomography(CT),112 CRL... Different sedimentary zones in coral reefs lead to significant anisotropy in the pore structure of coral reef limestone(CRL),making it difficult to study mechanical behaviors.With X-ray computed tomography(CT),112 CRL samples were utilized for training the support vector machine(SVM)-,random forest(RF)-,and back propagation neural network(BPNN)-based models,respectively.Simultaneously,the machine learning model was embedded into genetic algorithm(GA)for parameter optimization to effectively predict uniaxial compressive strength(UCS)of CRL.Results indicate that the BPNN model with five hidden layers presents the best training effect in the data set of CRL.The SVM-based model shows a tendency to overfitting in the training set and poor generalization ability in the testing set.The RF-based model is suitable for training CRL samples with large data.Analysis of Pearson correlation coefficient matrix and the percentage increment method of performance metrics shows that the dry density,pore structure,and porosity of CRL are strongly correlated to UCS.However,the P-wave velocity is almost uncorrelated to the UCS,which is significantly distinct from the law for homogenous geomaterials.In addition,the pore tensor proposed in this paper can effectively reflect the pore structure of coral framework limestone(CFL)and coral boulder limestone(CBL),realizing the quantitative characterization of the heterogeneity and anisotropy of pore.The pore tensor provides a feasible idea to establish the relationship between pore structure and mechanical behavior of CRL. 展开更多
关键词 Coral reef limestone(CRL) Machine learning Pore tensor x-ray computed tomography(CT)
下载PDF
Use of high-resolution X-ray computed tomography and 3D image analysis to quantify mineral dissemination and pore space in oxide copper ore particles 被引量:8
2
作者 Bao-hua Yang Ai-xiang Wu +2 位作者 Guillermo A.Narsilio Xiu-xiu Miao Shu-yue Wu 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2017年第9期965-973,共9页
Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance. To quantify the mineral dissemination and pore space distribution of an ore particle,... Mineral dissemination and pore space distribution in ore particles are important features that influence heap leaching performance. To quantify the mineral dissemination and pore space distribution of an ore particle, a cylindrical copper oxide ore sample (I center dot 4.6 mm x 5.6 mm) was scanned using high-resolution X-ray computed tomography (HRXCT), a nondestructive imaging technology, at a spatial resolution of 4.85 mu m. Combined with three-dimensional (3D) image analysis techniques, the main mineral phases and pore space were segmented and the volume fraction of each phase was calculated. In addition, the mass fraction of each mineral phase was estimated and the result was validated with that obtained using traditional techniques. Furthermore, the pore phase features, including the pore size distribution, pore surface area, pore fractal dimension, pore centerline, and the pore connectivity, were investigated quantitatively. The pore space analysis results indicate that the pore size distribution closely fits a log-normal distribution and that the pore space morphology is complicated, with a large surface area and low connectivity. This study demonstrates that the combination of HRXCT and 3D image analysis is an effective tool for acquiring 3D mineralogical and pore structural data. 展开更多
关键词 high-resolution x-ray computed tomography 3D image analysis ore particles mineral dissemination pore space
下载PDF
Evaluation of mitral chordae tendineae length using four-dimensional computed
3
作者 Takuya Mori Satoshi Matsushita +3 位作者 Terumasa Morita Abulaiti Abudurezake Junji Mochizuki Atsushi Amano 《World Journal of Cardiology》 2024年第5期274-281,共8页
BACKGROUND Mitral valvuloplasty using artificial chordae tendineae represents an effective surgical approach for treating mitral regurgitation.Achieving precise measurements of artificial chordae tendineae length(CL)i... BACKGROUND Mitral valvuloplasty using artificial chordae tendineae represents an effective surgical approach for treating mitral regurgitation.Achieving precise measurements of artificial chordae tendineae length(CL)is an important factor in the procedure;however,no objective index currently exists to facilitate this measurement.Therefore,preoperative assessment of CL is critical for surgical planning and support.Four-dimensional x-ray micro-computed tomography(4D-CT)may be useful for accurate CL measurement considering that it allows for dynamic three-dimensional(3D)evaluation compared to that with transthoracic echocardiography,a conventional inspection method.AIM To investigate the behavior and length of mitral chordae tendineae during systole using 4D-CT.METHODS Eleven adults aged>70 years without mitral valve disease were evaluated.A 64-slice CT scanner was used to capture 20 phases in the cardiac cycle in electrocardiographic synchronization.The length of the primary chordae tendineae was measured from early systole to early diastole using the 3D image.The primary chordae tendineae originating from the anterior papillary muscle and attached to the A1-2 region and those from the posterior papillary muscle and attached to the A2-3 region were designated as cA and cP,respectively.The behavior and maximum lengths[cA(ma),cP(max)]were compared,and the correlation with body surface area(BSA)was evaluated.RESULTS In all cases,the mitral anterior leaflet chordae tendineae could be measured.In most cases,the cA and cP chordae tendineae could be measured visually.The mean cA(max)and cP(max)were 20.2 mm±1.95 mm and 23.5 mm±4.06 mm,respectively.cP(max)was significantly longer.The correlation coefficients(r)with BSA were 0.60 and 0.78 for cA(max)and cP(max),respectively.Both cA and cP exhibited constant variation in CL during systole,with a maximum 1.16-fold increase in cA and a 1.23-fold increase in cP from early to mid-systole.For cP,CL reached a plateau at 15%and remained elongated until end-systole,whereas for cA,after peaking at 15%,CL shortened slightly and then moved toward its peak again as end-systole approached.CONCLUSION The study suggests that 4D-CT is a valuable tool for accurate measurement of both the length and behavior of chordae tendineae within the anterior leaflet of the mitral valve. 展开更多
关键词 Mitral valve Chordae tendineae computed tomography four-dimensional Cardiac cycle
下载PDF
Use of X-ray computed tomography to study structures and particle contacts of granite residual soil 被引量:14
4
作者 SUN Yin-lei TANG Lian-sheng 《Journal of Central South University》 SCIE EI CAS CSCD 2019年第4期938-954,共17页
A small problem about soil particle regularization and contacts but essential to geotechnical engineering was studied.The soils sourced from Guangzhou and Xiamen were sieved into five different particle scale ranges(d... A small problem about soil particle regularization and contacts but essential to geotechnical engineering was studied.The soils sourced from Guangzhou and Xiamen were sieved into five different particle scale ranges(d<0.075 mm,0.075 mm≤d<0.1 mm,0.1 mm≤d<0.2 mm,0.2 mm≤d<0.5 mm and 0.5 mm≤d<1.0 mm)to study the structures and particle contacts of granite residual soil.The X-ray micro computed tomography method was used to reconstruct the microstructure of granite residual soil.The particle was identified and regularized using principal component analysis(PCA).The particle contacts and geometrical characteristics in 3D space were analyzed and summarized using statistical analyses.The results demonstrate that the main types of contact among the particles are face-face,face-angle,face-edge,edge-edge,edge-angle and angle-angle contacts for particle sizes less than 0.2 mm.When the particle sizes are greater than 0.2 mm,the contacts are effectively summarized as face-face,face-angle,face-edge,edge-edge,edge-angle,angle-angle,sphere-sphere,sphere-face,sphere-edge and sphere-angle contacts.The differences in porosity among the original sample,reconstructed sample and regularized sample are closely related to the water-swelling and water-disintegrable characteristics of granite residual soil. 展开更多
关键词 x-ray computed tomography granite residual soil RECONSTRUCTION REGULARIZATION particle contact
下载PDF
Microstructure Evolution of Sandstone Cemented by Microbe Cement Using X-ray Computed Tomography 被引量:4
5
作者 RONG Hui QIAN Chunxiang 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2013年第6期1134-1139,共6页
The bio-sandstone, which was cemented by microbe cement, was firstly prepared, and then the microstructure evolution process was studied by X-ray computed tomography (X-CT) technique. The experimental results indica... The bio-sandstone, which was cemented by microbe cement, was firstly prepared, and then the microstructure evolution process was studied by X-ray computed tomography (X-CT) technique. The experimental results indicate that the microstructure of bio-sandstone becomes dense with the development of age. The evolution of inner structure at different positions is different due to the different contents of microbial induced precipitation calcite. Besides, the increase rate of microbial induced precipitation calcite gradually decreases because of the reduction of microbe absorption content with the decreasing pore size in bio-sandstone. 展开更多
关键词 microbe cement bio-sandstone microstructure evolution x-ray computed tomography CALCITE
下载PDF
Quantification of 3D macropore networks in forest soils in Touzhai valley(Yunnan,China)using X-ray computed tomography and image analysis 被引量:2
6
作者 ZHANG Jia-ming XU Ze-min +2 位作者 LI Feng HOU Ru-ji REN Zhe 《Journal of Mountain Science》 SCIE CSCD 2017年第3期474-491,共18页
The three dimensional (3D) geometry of soil macropores largely controls preferential flow, which is a significant infiltrating mechanism for rainfall in forest soils and affects slope stability. However, detailed st... The three dimensional (3D) geometry of soil macropores largely controls preferential flow, which is a significant infiltrating mechanism for rainfall in forest soils and affects slope stability. However, detailed studies on the 3D geometry of macropore networks in forest soils are rare. The intense rainfall-triggered potentially unstable slopes were threatening the villages at the downstream of Touzhai valley (Yunnan, China). We visualized and quantified the 3D macropore networks in undisturbed soil columns (Histosols) taken from a forest hillslope in Touzhai valley, and compared them with those in agricultural soils (corn and soybean in USA; barley, fodder beet and red fescue in Denmark) and grassland soils in USA. We took two large undisturbed soil columns (250 mm^25o mmxsoo mm), and scanned the soil columns at in-situ soil water content conditions using X-ray computed tomography at a voxel resolution of 0.945 × 0.945 × 1.500o mm^3. After reconstruction and visualization, we quantified the characteristics of macropore networks. In the studied forest soils, the main types of maeropores were root channels, inter-aggregate voids, maeropores without knowing origin, root-soil interfaee and stone-soil interface. While maeropore networks tend to be more eomplex, larger, deeper and longer. The forest soils have high maeroporosity, total maeropore wall area density, node density, and large maeropore volume, hydraulie radius, mean maeropore length, angle, and low tortuosity. The findings suggest that maeropore networks in the forest soils have high inter- connectivity, vertical continuity, linearity and less vertically oriented. 展开更多
关键词 Slope stability Touzhai valley Rainfall infiltration Forest soils x-ray computed tomography 3D macropore networks
下载PDF
In situ compression and X-ray computed tomography of flow battery electrodes 被引量:1
7
作者 Rhodri Jervis Matt D.R.Kok +6 位作者 Tobias P.Neville Quentin Meyer Leon D.Brown Francesco Iacoviello Jeff T.Gostick Dan J.L.Brett Paul R.Shearing 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2018年第5期1353-1361,共9页
Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised... Redox flow batteries offer a potential solution to an increase in renewable energy generation on the grid by offering long-term, large-scale storage and regulation of power. However, they are currently un- derutilised due to cost and performance issues, many of which are linked to the microstructure of the porous carbon electrodes used. Here, for the first time, we offer a detailed study of the in situ effects of compression on a commercially available carbon felt electrode. Visualisation of electrode structure us- ing X-ray computed tomography shows the non-linear way that these materials compress and various metrics are used to elucidate the changes in porosity, pore size distribution and tortuosity factor under compressions from 0%-90%. 展开更多
关键词 Redox flow battery x-ray computed tomography Compression Carbon felt RFB
下载PDF
Energy spectrum computed tomography multi-parameter imaging in preoperative assessment of vascular and neuroinvasive status in gastric cancer
8
作者 Jing Wang Jian-Cheng Liang +1 位作者 Fa-Te Lin Jun Ma 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第8期2511-2520,共10页
BACKGROUND Vascular and nerve infiltration are important indicators for the progression and prognosis of gastric cancer(GC),but traditional imaging methods have some limitations in preoperative evaluation.In recent ye... BACKGROUND Vascular and nerve infiltration are important indicators for the progression and prognosis of gastric cancer(GC),but traditional imaging methods have some limitations in preoperative evaluation.In recent years,energy spectrum computed tomography(CT)multiparameter imaging technology has been gradually applied in clinical practice because of its advantages in tissue contrast and lesion detail display.AIM To explore and analyze the value of multiparameter energy spectrum CT imaging in the preoperative assessment of vascular invasion(LVI)and nerve invasion(PNI)in GC patients.METHODS Data from 62 patients with GC confirmed by pathology and accompanied by energy spectrum CT scanning at our hospital between September 2022 and September 2023,including 46 males and 16 females aged 36-71(57.5±9.1)years,were retrospectively collected.The patients were divided into a positive group(42 patients)and a negative group(20 patients)according to the presence of LVI/PNI.The CT values(CT40 keV,CT70 keV),iodine concentration(IC),and normalized IC(NIC)of lesions in the upper energy spectrum CT images of the arterial phase,venous phase,and delayed phase 40 and 70 keV were measured,and the slopes of the energy spectrum curves[K(40-70)]from 40 to 70 keV were calculated.Arterial Core Tip:To investigate the application value of multiparameter energy spectrum computed tomography(CT)imaging in the preoperative assessment of vascular and nerve infiltration in patients with gastric cancer(GC).The imaging data of GC patients were retrospectively analyzed to evaluate the accuracy and sensitivity of CT for identifying and quantifying vascular and nerve infiltration and for comparison with postoperative pathological results.The purpose of this study was to verify the clinical feasibility and potential advantages of multiparameter energy spectrum CT imaging in guiding preoperative diagnosis and treatment decision-making and to provide a new imaging basis for improving the diagnostic accuracy and prognosis of GC patients. 展开更多
关键词 tomography x-ray computer Energy spectrum computed tomography Gastric cancer Vascular invasion Nerve invasion Cross-sectional study
下载PDF
Distinct root system acclimation patterns of seagrass Zostera japonica in sediments of different trophic status:a research by X-ray computed tomography
9
作者 Xiaoyue SONG Yi ZHOU +7 位作者 Jiangning ZENG Lu SHOU Xiaomei ZHANG Shidong YUE Wei GAO Weihua FENG Zhifu WANG Ping DU 《Journal of Oceanology and Limnology》 SCIE CAS CSCD 2021年第6期2267-2280,共14页
Conspecific seagrass living in differing environments may develop different root system acclimation patterns.We applied X-ray computed tomography(CT)for imaging and quantifying roots systems of Zostera japonica collec... Conspecific seagrass living in differing environments may develop different root system acclimation patterns.We applied X-ray computed tomography(CT)for imaging and quantifying roots systems of Zostera japonica collected from typical oligotrophic and eutrophic sediments in two coastal sites of northern China,and determined sediment physicochemical properties that might influence root system morphology,density,and distribution.The trophic status of sediments had little influence on the Z.japonica root length,and diameters of root and rhizome.However,Z.japonica in oligotrophic sediment developed the root system with longer rhizome node,deeper rhizome distribution,and larger allocation to below-ground tissues in order to acquire more nutrients and relieve the N deficiency.And the lower root and rhizome densities of Z.japonica in eutrophic sediment were mainly caused by fewer shoots and shorter longevity,which was resulted from the more serious sulfide inhibition.Our results systematically revealed the effect of sediment trophic status on the phenotypic plasticity,quantity,and distribution of Z.japonica root system,and demonstrated the feasibly of X-ray CT in seagrass root system research. 展开更多
关键词 Zostera japonica root system acclimation pattern SEDIMENT trophic status x-ray computed tomography
下载PDF
Computed tomography-based nomogram of Siewert type Ⅱ/Ⅲ adenocarcinoma of esophagogastric junction to predict response to docetaxel, oxaliplatin and S-1
10
作者 Chuan-Qinyuan Zhou Dan Gao +7 位作者 Yan Gui Ning-Pu Li Wen-Wen Guo Hai-Ying Zhou Rui Li Jing Chen Xiao-Ming Zhang Tian-Wu Chen 《World Journal of Radiology》 2024年第1期9-19,共11页
BACKGROUND Neoadjuvant chemotherapy(NAC)has become the standard care for advanced adenocarcinoma of esophagogastric junction(AEG),although a part of the patients cannot benefit from NAC.There are no models based on ba... BACKGROUND Neoadjuvant chemotherapy(NAC)has become the standard care for advanced adenocarcinoma of esophagogastric junction(AEG),although a part of the patients cannot benefit from NAC.There are no models based on baseline computed tomography(CT)to predict response of Siewert type II or III AEG to NAC with docetaxel,oxaliplatin and S-1(DOS).AIM To develop a CT-based nomogram to predict response of Siewert type II/III AEG to NAC with DOS.METHODS One hundred and twenty-eight consecutive patients with confirmed Siewert type II/III AEG underwent CT before and after three cycles of NAC with DOS,and were randomly and consecutively assigned to the training cohort(TC)(n=94)and the validation cohort(VC)(n=34).Therapeutic effect was assessed by disease-control rate and progressive disease according to the Response Evaluation Criteria in Solid Tumors(version 1.1)criteria.Possible prognostic factors associated with responses after DOS treatment including Siewert classification,gross tumor volume(GTV),and cT and cN stages were evaluated using pretherapeutic CT data in addition to sex and age.Univariate and multivariate analyses of CT and clinical features in the TC were performed to determine independent factors associated with response to DOS.A nomogram was established based on independent factors to predict the response.The predictive performance of the nomogram was evaluated by Concordance index(C-index),calibration and receiver operating characteristics curve in the TC and VC.RESULTS Univariate analysis showed that Siewert type(52/55 vs 29/39,P=0.005),pretherapeutic cT stage(57/62 vs 24/32,P=0.028),GTV(47.3±27.4 vs 73.2±54.3,P=0.040)were significantly associated with response to DOS in the TC.Multivariate analysis of the TC also showed that the pretherapeutic cT stage,GTV and Siewert type were independent predictive factors related to response to DOS(odds ratio=4.631,1.027 and 7.639,respectively;all P<0.05).The nomogram developed with these independent factors showed an excellent performance to predict response to DOS in the TC and VC(C-index:0.838 and 0.824),with area under the receiver operating characteristic curve of 0.838 and 0.824,respectively.The calibration curves showed that the practical and predicted response to DOS effectively coincided.CONCLUSION A novel nomogram developed with pretherapeutic cT stage,GTV and Siewert type predicted the response of Siewert type II/III AEG to NAC with DOS. 展开更多
关键词 Esophagogastric junction ADENOCARCINOMA Neoadjuvant chemotherapy RESPONSE tomography x-ray computed Predictor
下载PDF
Seeing through Materials:X-Ray Imaging Using Computed Tomography
11
作者 Yisheng Miao Chengpeng Xue +2 位作者 Xuelong Wu Zhongyao Li Junsheng Wang 《Journal of Beijing Institute of Technology》 EI CAS 2023年第4期494-516,共23页
X-ray computed tomography(XCT)has recently emerged as a powerful tool for characterizing the evolution of microstructure during phase transformation in three dimensional(3D)such as dendritic solidification of alloys.T... X-ray computed tomography(XCT)has recently emerged as a powerful tool for characterizing the evolution of microstructure during phase transformation in three dimensional(3D)such as dendritic solidification of alloys.This paper briefly reviews the recent advances in the in-situ observation of aluminium alloys,magnesium alloys and nickel-based superalloys during solidification using laboratory XCT and synchrotron X-ray sources.The focus is on the growth kinetics of dendrites,porosity and secondary phases.In addition,in-situ characterization during the loading and corrosion process is also discussed. 展开更多
关键词 x-ray computed tomography(XCT) SYNCHROTRON DENDRITE POROSITY ALLOYS
下载PDF
Importance of computed tomography in posterior malleolar fractures:Added information to preoperative X-ray studies
12
作者 NoéDe Marchi Neto Pietro Felice Tomazini Nesello +3 位作者 Jordanna Maria Bergamasco Marco Tulio Costa Ralph Walter Christian Nilson Roberto Severino 《World Journal of Orthopedics》 2023年第12期868-877,共10页
BACKGROUND Ankle fractures are common lesions of the lower limbs.Approximately 40%of ankle fractures affect the posterior malleolus(PM).Historically,PM osteosynthesis was recommended when PM size in X-ray images was g... BACKGROUND Ankle fractures are common lesions of the lower limbs.Approximately 40%of ankle fractures affect the posterior malleolus(PM).Historically,PM osteosynthesis was recommended when PM size in X-ray images was greater than 25%of the joint.Currently,computed tomography(CT)has been gaining traction in the preoperative evaluation of ankle fractures.AIM To elucidate the similarity in dimensions and to correlate PM size in X-ray images with the articular surface of the affected tibial plafond in the axial view on CT(AXCT)of a PM fracture.METHODS Eighty-one patients(mean age:39.4±13.5 years)were evaluated(54.3%were male).Two independent examiners measured PM size in profile X-ray images(PMXR)and sagittal CT(SAGCT)slices.The correlation of the measurements between the examiners and the difference in the PM fragment sizes between the two images were compared.Next,the PM size in PMXR was compared with the surface of the tibial plafond involved in the fracture in AXCT according to the Haraguchi classification.RESULTS The correlation rates between the examiners were 0.93 and 0.94 for PMXR and SAGCT,respectively(P<0.001).Fragments were 2.12%larger in SAGCT than in PMXR(P=0.018).In PMXR,there were 56 cases<25%and 25 cases≥25%.When PMXR was<25%,AXCT corresponded to 10.13%of the tibial plafond.When PMXR was≥25%,AXCT was 24.52%(P<0.001).According to the Haraguchi classification,fracture types I and II had similar PMXR measurements that were greater than those of type III.When analyzing AXCT,a significant difference was found between the three types,with II>I>III(P<0.001).CONCLUSION PM fractures show different sizes using X-ray or CT images.CT showed a larger PM in the sagittal plane and allowed the visualization of the real dimensions of the tibial plafond surface. 展开更多
关键词 Ankle fracture Posterior malleolar fracture computed tomography x-ray Posterior malleolus fracture Trimalleolar facture
下载PDF
Pancreatic neuroendocrine tumor detected by technetium-99m methoxy-2-isobutylisonitrile single photon emission computed tomography/computed tomography:A case report
13
作者 Chang-Jiang Liu Hua-Jun Yang +1 位作者 Yan-Chun Peng De-Yu Huang 《World Journal of Clinical Cases》 SCIE 2023年第12期2825-2831,共7页
BACKGROUND Pancreatic neuroendocrine tumors(NETs)account for about 1%–2%of pancreatic tumors and about 8%of all NETs.Computed tomography(CT),magnetic resonance imaging,and endoscopic ultrasound are common imaging mod... BACKGROUND Pancreatic neuroendocrine tumors(NETs)account for about 1%–2%of pancreatic tumors and about 8%of all NETs.Computed tomography(CT),magnetic resonance imaging,and endoscopic ultrasound are common imaging modalities for the diagnosis of pancreatic NETs.Furthermore,somatostatin receptor imaging is of great value for diagnosing pancreatic NETs.Herein,we report the efficacy of technetium-99m methoxy-2-isobutylisonitrile(99mTc-MIBI)single photon emission CT(SPECT)/CT for detecting pancreatic NETs.CASE SUMMARY A 57-year-old woman presented to our hospital with a 1-d history of persistent upper abdominal distending pain.The distending pain in the upper abdomen was aggravated after eating,with nausea and retching.Routine blood test results showed a high neutrophil percentage,low leukomonocyte and monocyte percentages,and low leukomonocyte and eosinophil counts.Amylase,liver and kidney function,and tumor markers alpha-fetoprotein,carcinoembryonic antigen,and cancer antigen(CA)125,CA72-4,CA19-9,and CA153 were normal.Abdominal CT showed a mass,with multiple calcifications between the pancreas and the spleen.The boundary between the mass and the pancreas and spleen was poorly defined.Contrast-enhanced CT revealed that the upper abdominal mass was unevenly and gradually enhanced.99mTc-MIBI SPECT/CT revealed that a focal radioactive concentration,with mild radioactive concentration extending into the upper abdominal mass,was present at the pancreatic body and tail.The 99mTc-MIBI SPECT/CT manifestations were consistent with the final pathological diagnosis of pancreatic NET.CONCLUSION 99mTc-MIBI SPECT/CT appears to be a valuable tool for detecting pancreatic NETs. 展开更多
关键词 Neuroendocrine tumors PANCREAS Tc-99m-Methoxy-2-isobutylisonitrile Single photon emission computed tomography x-ray computed tomography Case report
下载PDF
Can visceral fat parameters based on computed tomography be used to predict occult peritoneal metastasis in gastric cancer? 被引量:4
14
作者 Li-Ming Li Lei-Yu Feng +4 位作者 Chen-Chen Liu Wen-Peng Huang Yang Yu Peng-Yun Cheng Jian-Bo Gao 《World Journal of Gastroenterology》 SCIE CAS 2023年第15期2310-2321,共12页
BACKGROUND The preoperative prediction of peritoneal metastasis(PM)in gastric cancer would prevent unnecessary surgery and promptly indicate an appropriate treatment plan.AIM To explore the predictive value of viscera... BACKGROUND The preoperative prediction of peritoneal metastasis(PM)in gastric cancer would prevent unnecessary surgery and promptly indicate an appropriate treatment plan.AIM To explore the predictive value of visceral fat(VF)parameters obtained from preoperative computed tomography(CT)images for occult PM and to develop an individualized model for predicting occult PM in patients with gastric carcinoma(GC).METHODS A total of 128 confirmed GC cases(84 male and 44 female patients)that underwent CT scans were analyzed and categorized into PM-positive(n=43)and PM-negative(n=85)groups.The clinical characteristics and VF parameters of two regions of interest(ROIs)were collected.Univariate and stratified analyses based on VF volume were performed to screen for predictive characteristics for occult PM.Prediction models with and without VF parameters were established by multivariable logistic regression analysis.RESULTS The mean attenuations of VF_(ROI 1)and VF_(ROI 2)varied significantly between the PM-positive and PMnegative groups(P=0.044 and 0.001,respectively).The areas under the receiver operating characteristic curves(AUCs)of VF_(ROI 1)and VF_(ROI 2)were 0.599 and 0.657,respectively.The mean attenuation of VF_(ROI 2)was included in the final prediction combined model,but not an independent risk factor of PM(P=0.068).No significant difference was observed between the models with and without mean attenuation of VF(AUC:0.749 vs 0.730,P=0.339).CONCLUSION The mean attenuation of VF is a potential auxiliary parameter for predicting occult PM in patients with GC. 展开更多
关键词 Gastric carcinoma Peritoneal metastasis Visceral fat tomography x-ray computed Prediction Individualized model
下载PDF
Effects of dry-wet cycles on three-dimensional pore structure and permeability characteristics of granite residual soil using X-ray micro computed tomography 被引量:14
15
作者 Ran An Lingwei Kong +1 位作者 Xianwei Zhang Chengsheng Li 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2022年第3期851-860,共10页
Due to seasonal climate alterations,the microstructure and permeability of granite residual soil are easily affected by multiple dry-wet cycles.The X-ray micro computed tomography(micro-CT)acted as a nondestructive to... Due to seasonal climate alterations,the microstructure and permeability of granite residual soil are easily affected by multiple dry-wet cycles.The X-ray micro computed tomography(micro-CT)acted as a nondestructive tool for characterizing the microstructure of soil samples exposed to a range of damage levels induced by dry-wet cycles.Subsequently,the variations of pore distribution and permeability due to drywet cycling effects were revealed based on three-dimensional(3D)pore distribution analysis and seepage simulations.According to the results,granite residual soils could be separated into four different components,namely,pores,clay,quartz,and hematite,from micro-CT images.The reconstructed 3D pore models dynamically demonstrated the expanding and connecting patterns of pore structures during drywet cycles.The values of porosity and connectivity are positively correlated with the number of dry-wet cycles,which were expressed by exponential and linear functions,respectively.The pore volume probability distribution curves of granite residual soil coincide with the χ^(2)distribution curve,which verifies the effectiveness of the assumption of χ^(2)distribution probability.The pore volume distribution curves suggest that the pores in soils were divided into four types based on their volumes,i.e.micropores,mesopores,macropores,and cracks.From a quantitative and visual perspective,considerable small pores are gradually transformed into cracks with a large volume and a high connectivity.Under the action of dry-wet cycles,the number of seepage flow streamlines which contribute to water permeation in seepage simulation increases distinctly,as well as the permeability and hydraulic conductivity.The calculated hydraulic conductivity is comparable with measured ones with an acceptable error margin in general,verifying the accuracy of seepage simulations based on micro-CT results. 展开更多
关键词 Granite residual soil Dry-wet cycle x-ray micro computed tomography(micro-CT) Three-dimensional(3D)pore distribution Seepage simulations PERMEABILITY
下载PDF
Review of X-ray and computed tomography scan findings with a promising role of point of care ultrasound in COVID-19 pandemic 被引量:5
16
作者 Darshan Gandhi Kriti Ahuja +4 位作者 Hemal Grover Pranav Sharma Shantanu Solanki Nishant Gupta Love Patel 《World Journal of Radiology》 CAS 2020年第9期195-203,共9页
As healthcare professionals continue to combat the coronavirus disease 2019(COVID-19)infection worldwide,there is an increasing interest in the role of imaging and the relevance of various modalities.Since imaging not... As healthcare professionals continue to combat the coronavirus disease 2019(COVID-19)infection worldwide,there is an increasing interest in the role of imaging and the relevance of various modalities.Since imaging not only helps assess the disease at the time of diagnosis but also aids evaluation of response to management,it is critical to examine the role of different modalities currently in use,such as baseline X-rays and computed tomography scans carefully.In this article,we will draw attention to the critical findings for the radiologist.Further,we will look at point of care ultrasound,an increasingly a popular tool in diagnostic medicine,as a component of COVID-19 management. 展开更多
关键词 x-ray computed tomography Point of care ultrasound COVID-19 CORONAVIRUS WUHAN
下载PDF
X-ray Computed Tomography Characterization of 3D Tufted Twill Textile Composite for Aerostructures 被引量:1
17
作者 A.Saboktakin M.Shahrouz +1 位作者 T.Vu-Khanh J.Bicerano 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2019年第3期7-13,共7页
Damage assessments in three dimensional (3D) textile composites subjected to mechanical loading can be performed by non-destructive and destructive techniques.This paper applies the two techniques to investigate the f... Damage assessments in three dimensional (3D) textile composites subjected to mechanical loading can be performed by non-destructive and destructive techniques.This paper applies the two techniques to investigate the fracture behavior of 3D tufted textile composites.X-ray computed tomography as a non-destructive evaluation method is appropriate to detect damage locations and identify their progression in 3D textile composites.Destructive methods such as sectioning toward observing damage provide valuable information about damage patterns.The results of this research could be utilized to evaluate the initial cause of rupture in 3D tufted composites used in aerospace structures and analyze fracture modes and damage progression. 展开更多
关键词 x-ray computed tomography DAMAGE CHARACTERIZATION 3D composite TEXTILE PREFORM
下载PDF
Isotropic compression behavior of granular assembly with non-spherical particles by X-ray micro-computed tomography and discrete element modeling 被引量:1
18
作者 Nan Zhang Ahmadreza Hedayat +4 位作者 Shaoyang Han Runlin Yang Héctor Gelber Bolaños Sosa Juan JoséGonzález Cárdenas Guido Edgard SalasÁlvarez 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2021年第5期972-984,共13页
The particle morphological properties,such as sphericity,concavity and convexity,of a granular assembly significantly affect its macroscopic and microscopic compressive behaviors under isotropic loading condition.Howe... The particle morphological properties,such as sphericity,concavity and convexity,of a granular assembly significantly affect its macroscopic and microscopic compressive behaviors under isotropic loading condition.However,limited studies on investigating the microscopic behavior of the granular assembly with real particle shapes under isotropic compression were reported.In this study,X-ray computed tomography(mCT)and discrete element modeling(DEM)were utilized to investigate isotropic compression behavior of the granular assembly with regard to the particle morphological properties,such as particle sphericity,concavity and interparticle frictions.The mCT was first used to extract the particle morphological parameters and then the DEM was utilized to numerically investigate the influences of the particle morphological properties on the isotropic compression behavior.The image reconstruction from mCT images indicated that the presented particle quantification algorithm was robust,and the presented microscopic analysis via the DEM simulation demonstrated that the particle surface concavity significantly affected the isotropic compression behavior.The observations of the particle connectivity and local void ratio distribution also provided insights into the granular assembly under isotropic compression.Results found that the particle concavity and interparticle friction influenced the most of the isotropic compression behavior of the granular assemblies. 展开更多
关键词 x-ray computed tomography(mCT) Discrete element modeling(DEM) Isotropic compression Particle surface curvature Particle morphology
下载PDF
Performance evaluation of the simpli¯ed spherical harmonics approximation for cone-beam X-ray luminescence computed tomography imaging 被引量:1
19
作者 Haibo Zhang Guohua Geng +6 位作者 Yanrong Chen Fengjun Zhao Yuqing Hou Huangjian Yi Shunli Zhang Jingjing Yu Xiaowei He 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2017年第3期97-106,共10页
As an emerging molecular imaging modality,cone-beam X-ray luminescence computed tomog-raphy(CB-XLCT)uses X-ray-excitable probes to produce near-infrared(NIR)luminescence and then reconst ructs three-dimensional(3D)dis... As an emerging molecular imaging modality,cone-beam X-ray luminescence computed tomog-raphy(CB-XLCT)uses X-ray-excitable probes to produce near-infrared(NIR)luminescence and then reconst ructs three-dimensional(3D)distribution of the probes from surface measurements.A proper photon-transportation model is critical to accuracy of XLCT.Here,we presented a systematic comparison between the common-used Monte Carlo model and simplified spherical harmonics(SPN).The performance of the two methods was evaluated over several main spec-trums using a known XLCT material.We designed both a global measurement based on the cosine similarity and a locally-averaged relative error,to quantitatively assess these methods.The results show that the SP_(3) could reach a good balance between the modeling accuracy and computational efficiency for all of the tested emission spectrums.Besides,the SP_(1)(which is equivalent to the difusion equation(DE))can be a reasonable alternative model for emission wavelength over 692nm.In vivo experiment further demonstrates the reconstruction perfor-mance of the SP:and DE.This study would provide a valuable guidance for modeling the photon-transportation in CB-XLCT. 展开更多
关键词 Cone-beam x-ray luminescence computed tomography photon-transportation model .simplified spherical harmonics approximation diffusion equations.
下载PDF
X-Ray Computed Tomography for Root Quantification 被引量:1
20
作者 Bente Foereid 《Open Journal of Soil Science》 2015年第7期145-148,共4页
Soil cores from a field growing barley and barley mutants without root hairs under conventional and minimum tillage were sampled. They were X-ray scanned to produce a 3D image and then the roots were washed out and we... Soil cores from a field growing barley and barley mutants without root hairs under conventional and minimum tillage were sampled. They were X-ray scanned to produce a 3D image and then the roots were washed out and weight and length were determined by conventional means. Root volume and surface area were then calculated from the 3D images using state of the art software and methodology, and the measured and calculated measures were correlated. The only strong and significant correlation was between measured weight and calculated volume for mutants without root hairs. It is concluded that the software cannot segment out very small roots, but segmentation accuracy also depends on root structure in some unknown way. Any study using X-ray computed tomography to quantify roots as they grow in situ should start with a calibration for the conditions in question. 展开更多
关键词 ROOTS 3D IMAGE x-ray computed tomography
下载PDF
上一页 1 2 17 下一页 到第