期刊文献+
共找到88,553篇文章
< 1 2 250 >
每页显示 20 50 100
Effectiveness of magnetic resonance imaging and spiral computed tomography in the staging and treatment prognosis of colorectal cancer
1
作者 Lu-Na Bai Lu-Xian Zhang 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第7期2135-2144,共10页
BACKGROUND Colorectal cancer(CRC)is a prevalent cancer type in clinical settings;its early signs can be difficult to detect,which often results in late-stage diagnoses in many patients.The early detection and diagnosi... BACKGROUND Colorectal cancer(CRC)is a prevalent cancer type in clinical settings;its early signs can be difficult to detect,which often results in late-stage diagnoses in many patients.The early detection and diagnosis of CRC are crucial for improving treatment success and patient survival rates.Recently,imaging techniques have been hypothesized to be essential in managing CRC,with magnetic resonance imaging(MRI)and spiral computed tomography(SCT)playing a significant role in enhancing diagnostic and treatment approaches.AIM To explore the effectiveness of MRI and SCT in the preoperative staging of CRC and the prognosis of laparoscopic treatment.METHODS Ninety-five individuals admitted to Zhongshan Hospital Xiamen University underwent MRI and SCT and were diagnosed with CRC.The precision of MRI and SCT for the presurgical classification of CRC was assessed,and pathological staging was used as a reference.Receiver operating characteristic curves were used to evaluate the diagnostic efficacy of blood volume,blood flow,time to peak,permeability surface,blood reflux constant,volume transfer constant,and extracellular extravascular space volume fraction on the prognosis of patients with CRC.RESULTS Pathological biopsies confirmed the following CRC stages:23,23,32,and 17 at T1,T2,T3,and T4,respectively.There were 39 cases at the N0 stage,22 at N1,34 at N2,44 at M0 stage,and 51 at M1.Using pathological findings as the benchmark,the combined use of MRI and SCT for preoperative TNM staging in patients with CRC demonstrated superior sensitivity,specificity,and accuracy compared with either modality alone,with a statistically significant difference in accuracy(P<0.05).Receiver operating characteristic curve analysis revealed the predictive values for laparoscopic treatment prognosis,as indicated by the areas under the curve for blood volume,blood flow,time to peak,and permeability surface,blood reflux constant,volume transfer constant,and extracellular extravascular space volume fraction were 0.750,0.683,0.772,0.761,0.709,0.719,and 0.910,respectively.The corresponding sensitivity and specificity values were also obtained(P<0.05).CONCLUSION MRI with SCT is effective in the clinical diagnosis of patients with CRC and is worthy of clinical promotion. 展开更多
关键词 Magnetic resonance imaging spiral computed tomography Colorectal cancer PROGNOSIS Receiver operating characteristic curve Retrospective study
下载PDF
Study on sex differences and potential clinical value of threedimensional computerized tomography pelvimetry in rectal cancer patients
2
作者 Xiao-Cong Zhou Fei-Yue Ke +2 位作者 Gaurav Dhamija Hao Chen Qiang Wang 《World Journal of Gastrointestinal Oncology》 SCIE 2024年第3期773-786,共14页
BACKGROUND Laparoscopic rectal cancer radical surgery is a complex procedure affected by various factors.However,the existing literature lacks standardized parameters for the pelvic region and soft tissues,which hampe... BACKGROUND Laparoscopic rectal cancer radical surgery is a complex procedure affected by various factors.However,the existing literature lacks standardized parameters for the pelvic region and soft tissues,which hampers the establishment of consistent conclusions.AIM To comprehensively assess 16 pelvic and 7 soft tissue parameters through computerized tomography(CT)-based three-dimensional(3D)reconstruction,providing a strong theoretical basis to address challenges in laparoscopic rectal cancer radical surgery.METHODS We analyzed data from 218 patients who underwent radical laparoscopic surgery for rectal cancer,and utilized CT data for 3D pelvic reconstruction.Specific anatomical points were carefully marked and measured using advanced 3D modeling software.To analyze the pelvic and soft tissue parameters,we emp-loyed statistical methods including paired sample t-tests,Wilcoxon rank-sum tests,and correlation analysis.RESULTS The investigation highlighted significant sex disparities in 14 pelvic bone parameters and 3 soft tissue parameters.Males demonstrated larger measurements in pelvic depth and overall curvature,smaller measurements in pelvic width,a larger mesorectal fat area,and a larger anterior-posterior abdominal diameter.By contrast,females exhibited wider pelvises,shallower depth,smaller overall curvature,and an increased amount of subcutaneous fat tissue.However,there were no significant sex differences observed in certain parameters such as sacral curvature height,superior pubococcygeal diameter,rectal area,visceral fat area,waist circumference,and transverse abdominal diameter.CONCLUSION The reconstruction of 3D CT data enabled accurate pelvic measurements,revealing significant sex differences in both pelvic and soft tissue parameters.This study design offer potential in predicting surgical difficulties and creating personalized surgical plans for male rectal cancer patients with a potentially“difficult pelvis”,ultimately improving surgical outcomes.Further research and utilization of these parameters could lead to enhanced surgical methods and patient care in laparoscopic rectal cancer radical surgery. 展开更多
关键词 computerized tomography Rectal cancer Three-dimensional reconstruction PELVIMETRY Sex differences
下载PDF
Multilocular thymic cysts can be easily misdiagnosed as malignant tumor on computer tomography:A case report
3
作者 Jun Sun Qing-Ning Yang +5 位作者 Yi Guo Ping Zeng Long-Yan Ma Ling-Wen Kong Bo-Ying Zhao Chuan-Ming Li 《World Journal of Clinical Cases》 SCIE 2024年第8期1474-1480,共7页
BACKGROUND Multilocular thymic cyst(MTC)is a rare mediastinal lesion which is considered to occur in the process of acquired inflammation.It is usually characterized by well-defined cystic density and is filled with t... BACKGROUND Multilocular thymic cyst(MTC)is a rare mediastinal lesion which is considered to occur in the process of acquired inflammation.It is usually characterized by well-defined cystic density and is filled with transparent liquid.CASE SUMMARY We report on a 39-year-old male with a cystic-solid mass in the anterior mediastinum.Computer tomography(CT)imaging showed that the mass was irregular with unclear boundaries.After injection of contrast agent,there was a slight enhancement of stripes and nodules.According to CT findings,it was diagnosed as thymic cancer.CONCLUSION After surgery,MTC accompanied by bleeding and infection was confirmed by pathological examination.The main lesson of this case was that malignant thymic tumor and MTC of the anterior mediastinum sometimes exhibit similar CT findings.Caution is necessary in clinical work to avoid misdiagnosis. 展开更多
关键词 Multilocular thymic cyst computer tomography MISDIAGNOSIS HEMORRHAGE INFECTION Case report
下载PDF
Avoiding misdiagnosis of multilocular thymic cysts as malignant tumors on computer tomography
4
作者 Yu-Hong Zhang Yan-Miao Liu +2 位作者 Kai-Li Shen Jing-Jing Wu Fu-Shan Tang 《World Journal of Clinical Cases》 SCIE 2024年第19期3671-3675,共5页
This editorial provides insights from a case report by Sun et al published in the World Journal of Clinical Cases.The case report focuses on a case where a multilocular thymic cyst(MTC)was misdiagnosed as a thymic tum... This editorial provides insights from a case report by Sun et al published in the World Journal of Clinical Cases.The case report focuses on a case where a multilocular thymic cyst(MTC)was misdiagnosed as a thymic tumor,resulting in an unnecessary surgical procedure.Both MTCs and thymic tumors are rare conditions that heavily rely on radiological imaging for accurate diagnosis.However,the similarity in their imaging presentations can lead to misinterpretation,resulting in unnecessary surgical procedures.Due to the ongoing lack of comprehensive knowledge about MTCs and thymic tumors,we offer a summary of diagnostic techniques documented in recent literature and examine potential causes of misdiagnosis.When computer tomography(CT)values surpass 20 Hounsfield units and display comparable morphology,there is a risk of misdiagnosing MTCs as thymic tumors.Employing various differential diagnostic methods like biopsy,molecular biology,multi-slice CT,CT functional imaging,positron emission tomography/CT molecular functional imaging,magnetic resonance imaging and radiomics,proves advantageous in reducing clinical misdiagnosis.A deeper understanding of these conditions requires increased attention and exploration by healthcare providers.Moreover,the continued advancement and utilization of various diagnostic methods are expected to enhance precise diagnoses,provide appropriate treatment options,and improve the quality of life for patients with thymic tumors and MTCs in the future.continued advancement and utilization of various diagnostic methods are expected to enhance precise diagnoses,provide appropriate treatment options,and improve the quality of life for patients with thymic tumors and MTCs in the future. 展开更多
关键词 Thymic tumor Multilocular thymic cyst MISDIAGNOSIS Differential diagnosis Imaging manifestation Computed tomography
下载PDF
Computerized tomography-guided therapeutic percutaneous puncture catheter drainage-combined with somatostatin for severe acute pancreatitis: An analysis of efficacy and safety
5
作者 Xue-Lan Zheng Wan-Ling Li +1 位作者 Yan-Ping Lin Ting-Long Huang 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第1期59-66,共8页
BACKGROUND Severe acute pancreatitis(SAP),a condition with rapid onset,critical condition and unsatisfactory prognosis,poses a certain threat to human health,warranting optimization of relevant treatment plans to impr... BACKGROUND Severe acute pancreatitis(SAP),a condition with rapid onset,critical condition and unsatisfactory prognosis,poses a certain threat to human health,warranting optimization of relevant treatment plans to improve treatment efficacy.AIM To evaluate the efficacy and safety of computerized tomography-guided the-rapeutic percutaneous puncture catheter drainage(CT-TPPCD)combined with somatostatin(SS)in the treatment of SAP.METHODS Forty-two SAP patients admitted to The Second Affiliated Hospital of Fujian Medical University from June 2020 to June 2023 were selected.On the basis of routine treatment,20 patients received SS therapy(control group)and 22 patients were given CT-TPPCD plus SS intervention(research group).The efficacy,safety(pancreatic fistula,intra-abdominal hemorrhage,sepsis,and organ dysfunction syndrome),abdominal bloating and pain relief time,bowel recovery time,hospital stay,inflammatory indicators(C-reactive protein,interleukin-6,and pro-calcitonin),and Acute Physiology and Chronic Health Evaluation(APACHE)II score of both groups were evaluated for comparison.RESULTS Compared with the control group,the research group had a markedly higher total effective rate,faster abdominal bloating and pain relief and bowel recovery,INTRODUCTION Pancreatitis,an inflammatory disease occurring in the pancreatic tissue,is classified as either acute or chronic and is associated with high morbidity and mortality,imposing a socioeconomic burden[1,2].The pathogenesis of this disease involves early protease activation,activation of nuclear factor kappa-B-related inflammatory reactions,and infiltration of immune cells[3].Severe acute pancreatitis(SAP)is a serious condition involving systemic injury and subsequent possible organ failure,accounting for 20%of all acute pancreatitis cases[4].SAP is also characterized by rapid onset,critical illness and unsatisfactory prognosis and is correlated with serious adverse events such as systemic inflammatory response syn-drome and acute lung injury,threatening the health of patients[5,6].Therefore,timely and effective therapeutic inter-ventions are of great significance for improving patient prognosis and ensuring therapeutic effects.Somatostatin(SS),a peptide hormone that can be secreted by endocrine cells and the central nervous system,is in-volved in the regulatory mechanism of glucagon and insulin synthesis in the pancreas[7].It has complex and pleiotropic effects on the gastrointestinal tract,which can inhibit the release of gastrointestinal hormones and negatively modulate the exocrine function of the stomach,pancreas and bile,while exerting a certain influence on the absorption of the di-gestive system[8,9].SS has shown certain clinical effectiveness when applied to SAP patients and can regulate the severity of SAP and immune inflammatory responses,and this regulation is related to its influence on leukocyte apoptosis and adhesion[10,11].Computerized tomography-guided therapeutic percutaneous puncture catheter drainage(CT-TPPCD)is a surgical procedure to collect lesion fluid and pus samples from necrotic lesions and perform puncture and drainage by means of CT image examination and precise positioning[12].In the research of Liu et al[13],CT-TPPCD applied to pa-tients undergoing pancreatic surgery contributes to not only good curative effects but also a low surgical risk.Baudin et al[14]also reported that CT-TPPCD has a clinical success rate of 64.6%in patients with acute infectious necrotizing pan-creatitis,with nonfatal surgery-related complications found in only two cases,suggesting that this procedure is clinically effective and safe in the treatment of the disease.In light of the limited studies on the efficacy and safety of SS plus CT-TPPCD in SAP treatment,this study performed a relevant analysis to improve clinical outcomes in SAP patients. 展开更多
关键词 computerized tomography guidance Therapeutic percutaneous puncture catheter drainage SOMATOSTATIN Severe acute pancreatitis Efficacy and safety
下载PDF
Efficacy of multi-slice spiral computed tomography in evaluating gastric cancer recurrence after endoscopic submucosal dissection 被引量:2
6
作者 Jian-Jun Yin Xiao Hu +1 位作者 Sen Hu Guo-Hong Sheng 《World Journal of Gastrointestinal Oncology》 SCIE 2023年第9期1636-1643,共8页
BACKGROUND Recurrence is the major challenge facing endoscopic submucosal dissection(ESD)-based treatment therapies for early gastric cancer(EGC).Urgent development of simple and easy surveillance approaches will enha... BACKGROUND Recurrence is the major challenge facing endoscopic submucosal dissection(ESD)-based treatment therapies for early gastric cancer(EGC).Urgent development of simple and easy surveillance approaches will enhance clinical treatment of the disease.AIM To explore the role of computed tomography(CT)recurrence in evaluating EGC after ESD treatment.METHODS We retrospectively recruited patients from our endoscopy department,between January 2002 and December 2015,and analyzed their basic characteristics,including symptoms,CT results,and results of endoscopy with biopsy,among others.RESULTS Among a total of 2150 patients EGC patients surveyed,1362 met our inclusion and exclusion criteria and were therefore enrolled in our study.The cohort’s sensitivity of CT for recurrent GC and specificity were 44.22%and 43.86%,respectively,with negative and positive predictive values of 40.15%(275/685)and 48.01%(325/677),respectively.The area under the curve of arterial and venous CT values for recurrent EGC were 0.545,and 0.604,respectively.Receiver operating characteristic curve revealed no statistically significant differences between arterial and venous CT values for recurrent EGC.CONCLUSION Enhanced CT has superior diagnostic efficacy,but less accuracy,compared to gold standard techniques in patients with recurrent EGC. 展开更多
关键词 Computed tomography Early gastric cancer Gastric cancer Multi-slice spiral computed tomography
下载PDF
Aflibercept combined with triamcinolone acetonide in the treatment of diabetic macular edema:optical coherence tomography and optical coherence tomography angiography
7
作者 De-Shuang Li Hong-Xia Liao +4 位作者 Chuan-He Zhang Jian-Guo Huang Wei Chen Jing-Lin Zhang Bo Qin 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第4期670-675,共6页
AIM:To analyze the relationship between optical coherence tomography(OCT)and OCT angiography(OCTA)imaging in patients with diabetic macular edema(DME)who are treated with a combination of aflibercept and triamcinolone... AIM:To analyze the relationship between optical coherence tomography(OCT)and OCT angiography(OCTA)imaging in patients with diabetic macular edema(DME)who are treated with a combination of aflibercept and triamcinolone acetonide(TA).METHODS:A total of 76 eyes newly diagnosed DME were included in this study.They were randomly assigned to receive either aflibercept or a combination of aflibercept and TA.Injections once a month for a total of three injections.Central macular thickness(CMT),number of hyperreflective foci(HRF),height of subretinal fluid(SRF),and area of foveal avascular zone(FAZ)were evaluated using OCT and OCTA at baseline and after each monthly treatment.RESULTS:Both groups showed improvement in best corrected visual acuity(BCVA)and reduction in macular edema after treatment,and the difference in BCVA between the two groups was statistically significant after each treatment(P<0.05).The difference in CMT between the two groups was statistically significant after the first two injections(P<0.01),but not after the third injection(P=0.875).The number of HRF(1mo:7.41±8.25 vs 10.86±7.22,P=0.027;2mo:5.33±6.13 vs 9.12±8.61,P=0.034;3mo:3.58±3.00 vs 6.37±5.97,P=0.007)and height of SRF(1mo:82.39±39.12 vs 105.77±42.26μm,P=0.011;2mo:36.84±10.02 vs 83.59±37.78μm,P<0.01;3mo:11.57±3.29 vs 45.43±12.60μm,P<0.01)in combined group were statistically significant less than aflibercept group after each injection,while the area of FAZ showed no significant change before and after treatment in both groups.CONCLUSION:The combination therapy of aflibercept and TA shows more significant effects on DME eyes with decreased HRF and SRF.However,both aflibercept and combination therapy show no significant change in the area of FAZ. 展开更多
关键词 diabetic macular edema optical coherence tomography optical coherence tomography angiography hyperreflective foci subretinal fluid foveal avascular zone AFLIBERCEPT
下载PDF
Computed tomography for prediction of esophageal variceal bleeding
8
作者 Mohammed Elhendawy Ferial Elkalla 《World Journal of Gastrointestinal Endoscopy》 2024年第3期175-177,共3页
This letter to the editor relates to the study entitled“The role of computed tomography for the prediction of esophageal variceal bleeding:Current status and future perspectives”.Esophageal variceal bleeding(EVB)is ... This letter to the editor relates to the study entitled“The role of computed tomography for the prediction of esophageal variceal bleeding:Current status and future perspectives”.Esophageal variceal bleeding(EVB)is one of the most common and severe complications related to portal hypertension(PH).Despite marked advances in its management during the last three decades,EVB is still associated with significant morbidity and mortality.The risk of first EVB is related to the severity of both PH and liver disease,and to the size and endoscopic appearance of esophageal varices.Indeed,hepatic venous pressure gradient(HVPG)and esophagogastroduodenoscopy(EGD)are currently recognized as the“gold standard”and the diagnostic reference standard for the prediction of EVB,respectively.However,HVPG is an invasive,expensive,and technically complex procedure,not widely available in clinical practice,whereas EGD is mainly limited by its invasive nature.In this scenario,computed tomography(CT)has been recently proposed as a promising modality for the non-invasive prediction of EVB.While CT serves solely as a diagnostic tool and cannot replace EGD or HVPG for delivering therapeutic and physiological information,it has the potential to enhance the prediction of EVB more effectively when combined with liver disease scores,HVPG,and EGD.However,to date,evidence concerning the role of CT in this setting is still lacking,therefore we aim to summarize and discuss the current evidence concerning the role of CT in predicting the risk of EVB. 展开更多
关键词 Esophageal variceal bleeding Variceal upper gastrointestinal bleeding Portal hypertension Computed tomography Computed tomography angiography
下载PDF
Intravascular photoacoustic and optical coherence tomography imaging dual-mode system for detecting spontaneous coronary artery dissection: A feasibility study 被引量:1
9
作者 Yongwei Wang Yuyang Wan Zhongjiang Chen 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第1期77-86,共10页
In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary ... In this work,we present an intravascular dual-mode endoscopic system capable of both intravascular photoacoustic imaging(IVPAI)and intravascular optical coherence tomography(IVOCT)for recognizing spontaneous coronary artery dissection(SCAD)phantoms.IVPAI provides high-resolution and high-penetration images of intramural hematoma(IMH)at different depths,so it is especially useful for imaging deep blood clots associated with imaging phantoms.IVOCT can readily visualize the double-lumen morphology of blood vessel walls to identify intimal tears.We also demonstrate the capability of this dual-mode endoscopic system using mimicking phantoms and biological samples of blood clots in ex vivo porcine arteries.The results of the experiments indicate that the combined IVPAI and IVOCT technique has the potential to provide a more accurate SCAD assessment method for clinical applications. 展开更多
关键词 Spontaneous coronary artery dissection(SCAD) intravascular optical coherence tomography(IVOCT) intravascular photoacoustic imaging(IVPAI)
下载PDF
Detection of tracheal branching with computerized tomography:The relationship between the angles and age-gender
10
作者 Şevket Kahraman Mesut Furkan Yazar +2 位作者 Hüseyin Aydemir Mecit Kantarci Sonay Aydin 《World Journal of Radiology》 2023年第4期118-126,共9页
BACKGROUND The data obtained on the anatomical knowledge of the tracheobronchial system can be used for diagnosis,treatment and interventional interventions in areas such as anesthesia,thoracic surgery,pulmonary physi... BACKGROUND The data obtained on the anatomical knowledge of the tracheobronchial system can be used for diagnosis,treatment and interventional interventions in areas such as anesthesia,thoracic surgery,pulmonary physiology.AIM To determine the tracheobronchial branching angles in pediatric and adult populations by using the multislice computed tomography(CT)and minimum intensity projection(MinIP)technique,which is a non-invasive method.METHODS Our study was carried out retrospectively.Patients who underwent contrast and non-contrast CT examination,whose anatomically and pathophysiologically good tracheobronchial system and lung parenchyma images were obtained,were included in the study.Measurements were made in the coronal plane of the lung parenchyma.In the coronal plane,right main bronchus-left main bronchus angle,right upper lobe bronchus-intermedius bronchus angle,right middle lobe bronchus-right lower lobe bronchus angle,left upper lobe bronchus-left lower lobe bronchus angle were measured.RESULTS The study population consisted of 1511 patients,753 pediatric(mean age:13.4±4.3;range:1-18 years)and 758 adults(mean age:54.3±17.3;range:19-94 years).In our study,tracheal bifurcation angle was found to be 73.3°±13.7°(59.6°-87°)in the whole population.In the pediatric group,the right-left main coronal level was found to be higher in boys compared to girls(74.6°±12.9°vs 71.2°±13.9°,P=0.001).In the adult group,the right-left main coronal level was found to be lower in males compared to females(71.9°±12.9°vs 75.8°±14.7°,P<0.001).CONCLUSIONS Our study,with the number of 1511 patients,is the first study in the literature with the largest number of patient populations including pediatric and adult demographic data,measuring the angle values of the tracheobronchial system using multislice CT and MinIP technique.Study data will not only be a guide during invasive procedures,but it can also guide studies to be done with imaging methods. 展开更多
关键词 Tracheobronchial branching angles Subcarinal angle Multislice computerized tomography Minimum intensity projection technique
下载PDF
A deep learning model based on contrast-enhanced computed tomography for differential diagnosis of gallbladder carcinoma
11
作者 Fei Xiang Qing-Tao Meng +4 位作者 Jing-Jing Deng Jie Wang Xiao-Yuan Liang Xing-Yu Liu Sheng Yan 《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS CSCD 2024年第4期376-384,共9页
Background:Gallbladder carcinoma(GBC)is highly malignant,and its early diagnosis remains difficult.This study aimed to develop a deep learning model based on contrast-enhanced computed tomography(CT)images to assist r... Background:Gallbladder carcinoma(GBC)is highly malignant,and its early diagnosis remains difficult.This study aimed to develop a deep learning model based on contrast-enhanced computed tomography(CT)images to assist radiologists in identifying GBC.Methods:We retrospectively enrolled 278 patients with gallbladder lesions(>10 mm)who underwent contrast-enhanced CT and cholecystectomy and divided them into the training(n=194)and validation(n=84)datasets.The deep learning model was developed based on ResNet50 network.Radiomics and clinical models were built based on support vector machine(SVM)method.We comprehensively compared the performance of deep learning,radiomics,clinical models,and three radiologists.Results:Three radiomics features including LoG_3.0 gray-level size zone matrix zone variance,HHL firstorder kurtosis,and LHL gray-level co-occurrence matrix dependence variance were significantly different between benign gallbladder lesions and GBC,and were selected for developing radiomics model.Multivariate regression analysis revealed that age≥65 years[odds ratios(OR)=4.4,95%confidence interval(CI):2.1-9.1,P<0.001],lesion size(OR=2.6,95%CI:1.6-4.1,P<0.001),and CA-19-9>37 U/mL(OR=4.0,95%CI:1.6-10.0,P=0.003)were significant clinical risk factors of GBC.The deep learning model achieved the area under the receiver operating characteristic curve(AUC)values of 0.864(95%CI:0.814-0.915)and 0.857(95%CI:0.773-0.942)in the training and validation datasets,which were comparable with radiomics,clinical models and three radiologists.The sensitivity of deep learning model was the highest both in the training[90%(95%CI:82%-96%)]and validation[85%(95%CI:68%-95%)]datasets.Conclusions:The deep learning model may be a useful tool for radiologists to distinguish between GBC and benign gallbladder lesions. 展开更多
关键词 Gallbladder carcinoma Computed tomography Deep learning Radiomics
下载PDF
Gates joint locally connected network for accurate and robust reconstruction in optical molecular tomography
12
作者 Minghua Zhao Yahui Xiao +2 位作者 Jiaqi Zhang Xin Cao Lin Wang 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期11-22,共12页
Optical molecular tomography(OMT)is a potential pre-clinical molecular imaging technique with applications in a variety of biomedical areas,which can provide non-invasive quantitative three-dimensional(3D)information ... Optical molecular tomography(OMT)is a potential pre-clinical molecular imaging technique with applications in a variety of biomedical areas,which can provide non-invasive quantitative three-dimensional(3D)information regarding tumor distribution in living animals.The construction of optical transmission models and the application of reconstruction algorithms in traditional model-based reconstruction processes have affected the reconstruction results,resulting in problems such as low accuracy,poor robustness,and long-time consumption.Here,a gates joint locally connected network(GLCN)method is proposed by establishing the mapping relationship between the inside source distribution and the photon density on surface directly,thus avoiding the extra time consumption caused by iteration and the reconstruction errors caused by model inaccuracy.Moreover,gates module was composed of the concatenation and multiplication operators of three different gates.It was embedded into the network aiming at remembering input surface photon density over a period and allowing the network to capture neurons connected to the true source selectively by controlling three different gates.To evaluate the performance of the proposed method,numerical simulations were conducted,whose results demonstrated good performance in terms of reconstruction positioning accuracy and robustness. 展开更多
关键词 Optical molecular tomography gates module positioning accuracy ROBUSTNESS
下载PDF
The risk of prostate cancer on incidental finding of an avid prostate uptake on 2-deoxy-2-[^(18)F]fluoro-D-glucose positron emission tomography/computed tomography for non-prostate cancer-related pathology:A single centre retrospective study
13
作者 Anthony Franklin Troy Gianduzzo +7 位作者 Boon Kua David Wong Louise McEwan James Walters Rachel Esler Matthew J.Roberts Geoff Coughlina John W.Yaxley 《Asian Journal of Urology》 CSCD 2024年第1期33-41,共9页
Objective:To review the risk of prostate cancer(PCa)in men with incidentally reported increased intraprostatic uptake at 2-deoxy-2-[18F]fluoro-d-glucose positron emission tomography/computed tomography(18F-FDG PET/CT)... Objective:To review the risk of prostate cancer(PCa)in men with incidentally reported increased intraprostatic uptake at 2-deoxy-2-[18F]fluoro-d-glucose positron emission tomography/computed tomography(18F-FDG PET/CT)ordered at Department of Urology,The Wesley Hospital,Brisbane,QLD,Australia for non-PCa related pathology.Methods:Retrospective analysis of consecutive men between August 2014 and August 2019 presenting to a single institution for 18F-FDG PET/CT for non-prostate related conditions was conducted.Men were classified as benign,indeterminate,or malignant depending of the results of prostate-specific antigen(PSA),PSA velocity,biopsy histopathology,and three-Tesla(3 T)multiparametric MRI(mpMRI)Prostate Imaging Reporting and Data System score,or gallium-68-prostate-specific membrane antigen(68Ga-PSMA)PET/CT results.Results:Three percent(273/9122)of men demonstrated 18F-FDG avidity within the prostate.Eighty-five percent(231/273)were further investigated,including with PSA tests(227/231,98.3%),3 T mpMRI(68/231,29.4%),68Ga-PSMA PET/CT(33/231,14.3%),and prostate biopsy(57/231,24.7%).Results were considered benign in 130/231(56.3%),indeterminate in 31/231(13.4%),and malignant in 70/231(30.3%).PCa was identified in 51/57(89.5%)of the men who proceeded to biopsy,including 26/27(96.3%)men with Prostate Imaging Reporting and Data System scores 4-5 mpMRI and six men with a positive 68Ga-PSMA PET/CT.The most common Gleason score on biopsy was greater than or equal to 4+5(14/51,27.5%).68Ga-PSMA PET/CT was concordant with the 18F-FDG findings in 26/33(78.8%).All 13 men with a positive concordant 18F-FDG,3 T mpMRI,and 68Ga-PSMA PET/CT had PCa on biopsy.There was no statistically significant difference in the 18F-FDG maximum standardized uptake value between the benign or malignant groups(5.7 vs.6.1;p=0.580).Conclusion:In this study,after an incidental finding of an avid intraprostatic lesion on 18F-FDG PET/CT,70 of the 231 cases(30.3%;0.8%of the entire cohort)had results consistent with PCa,most commonly as Gleason score greater than or equal to 4+5 disease.Unless there is limited life expectancy due to competing medical co-morbidity,men with an incidental finding of intraprostatic uptake on 18F-FDG should be further investigated using principles of PCa detection. 展开更多
关键词 Prostatecancer Positionemission tomography Multiparametric magneticresonance imaging Prostatebiopsy
下载PDF
Distal-scanning common path probe for optical coherence tomography
14
作者 Zhengyu Chen Bin He +8 位作者 Zichen Yin Zhangwei Hu Yejiong Shi Chengming Wang Xiao Zhang Ning Zhang Linkai Jing Guihuai Wang Ping Xue 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期84-92,共9页
In this paper,we present a distal-scanning common path probe for optical coherence tomography(OCT)equipped with a hollow ultrasonic motor and a simple and specially designed beam-splitter.This novel probe proves to be... In this paper,we present a distal-scanning common path probe for optical coherence tomography(OCT)equipped with a hollow ultrasonic motor and a simple and specially designed beam-splitter.This novel probe proves to be able to effectively circumvent polarization and dispersion mismatch caused by fiber motion and is more robust to a variety of interfering factors during the imaging process,experimentally compared to a conventional noncommon path probe.Furthermore,our design counteracts the attenuation of backscattering with depth and the fall-off of the signal,resulting in a more balanced signal range and greater imaging depth.Spectral-domain OCT imaging of phantom and biological tissue is also demonstrated with a sensitivity of∼100dB and a lateral resolution of∼3μm.This low-cost probe offers simplified system configuration and excellent robustness,and is therefore particularly suitable for clinical diagnosis as one-off medical apparatus. 展开更多
关键词 Common path optical coherence tomography endoscopic probe
下载PDF
Contribution of Computed Tomography to the Diagnosis of Urinary Lithiasis in a West African University Hospital
15
作者 Some Milckisédek Judicaël Marouruana Tankoano Aïda Ida +5 位作者 Ouedraogo Pakisba Ali Tonde Kouka François Dassis Kindo Bassirou Zanga Soré Moussa Ouedraogo Nina-Astrid Bamouni Yomboé Abel 《Open Journal of Radiology》 2024年第2期25-32,共8页
Introduction: Urinary lithiasis is defining as a condition characterized by the formation of concretions in the kidneys or urinary excretory tract. We aimed to study professional practice in CT urinary lithiasis at CH... Introduction: Urinary lithiasis is defining as a condition characterized by the formation of concretions in the kidneys or urinary excretory tract. We aimed to study professional practice in CT urinary lithiasis at CHUYO. Materials and method: This was a descriptive cross-sectional study with retrospective data collection covering 3 years from January 2017 to December 2019. Results: In general, it was noted that CT scans in our environment provide all the elements needed by urologists to diagnose urinary lithiasis and its impact on the urinary system. However, there are shortcomings, particularly in terms of the accuracy of the shape and density of the stones in the CT scan reports, which does not make it easier for urologists to decide on treatment. Conclusion: Computed tomography plays a major role in the diagnosis and therapeutic management of urinary lithiasis, and its use needs to be improved in our context. 展开更多
关键词 Computed tomography Urinary Lithiasis DIAGNOSIS CHUYO
下载PDF
Triple-path feature transform network for ring-array photoacoustic tomography image reconstruction
16
作者 Lingyu Ma Zezheng Qin +1 位作者 Yiming Ma Mingjian Sun 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期23-40,共18页
Photoacoustic imaging(PAI)is a noninvasive emerging imaging method based on the photoacoustic effect,which provides necessary assistance for medical diagnosis.It has the characteristics of large imaging depth and high... Photoacoustic imaging(PAI)is a noninvasive emerging imaging method based on the photoacoustic effect,which provides necessary assistance for medical diagnosis.It has the characteristics of large imaging depth and high contrast.However,limited by the equipment cost and reconstruction time requirements,the existing PAI systems distributed with annular array transducers are difficult to take into account both the image quality and the imaging speed.In this paper,a triple-path feature transform network(TFT-Net)for ring-array photoacoustic tomography is proposed to enhance the imaging quality from limited-view and sparse measurement data.Specifically,the network combines the raw photoacoustic pressure signals and conventional linear reconstruction images as input data,and takes the photoacoustic physical model as a prior information to guide the reconstruction process.In addition,to enhance the ability of extracting signal features,the residual block and squeeze and excitation block are introduced into the TFT-Net.For further efficient reconstruction,the final output of photoacoustic signals uses‘filter-then-upsample’operation with a pixel-shuffle multiplexer and a max out module.Experiment results on simulated and in-vivo data demonstrate that the constructed TFT-Net can restore the target boundary clearly,reduce background noise,and realize fast and high-quality photoacoustic image reconstruction of limited view with sparse sampling. 展开更多
关键词 Deep learning feature transformation image reconstruction limited-view measurement photoacoustic tomography.
下载PDF
Plasma current tomography for HL-2A based on Bayesian inference
17
作者 刘自结 王天博 +5 位作者 吴木泉 罗正平 王硕 孙腾飞 肖炳甲 李建刚 《Plasma Science and Technology》 SCIE EI CAS CSCD 2024年第5期165-173,共9页
An accurate plasma current profile has irreplaceable value for the steady-state operation of the plasma.In this study,plasma current tomography based on Bayesian inference is applied to an HL-2A device and used to rec... An accurate plasma current profile has irreplaceable value for the steady-state operation of the plasma.In this study,plasma current tomography based on Bayesian inference is applied to an HL-2A device and used to reconstruct the plasma current profile.Two different Bayesian probability priors are tried,namely the Conditional Auto Regressive(CAR)prior and the Advanced Squared Exponential(ASE)kernel prior.Compared to the CAR prior,the ASE kernel prior adopts nonstationary hyperparameters and introduces the current profile of the reference discharge into the hyperparameters,which can make the shape of the current profile more flexible in space.The results indicate that the ASE prior couples more information,reduces the probability of unreasonable solutions,and achieves higher reconstruction accuracy. 展开更多
关键词 plasma current tomography Bayesian inference machine learning Gaussian distribution
下载PDF
Comparison of ocular biometric parameters between two swept-source optical coherence tomography devices and Scheimpflug tomography in patients with cataract
18
作者 Shan Ma Cheng Li +6 位作者 Jing Sun Jun Yang Kai Wen Xi-Teng Chen Fang-Yu Zhao Rong-Yu Gao Fang Tian 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第8期1437-1446,共10页
AIM:To assess and compare the variations and agreements across different ocular biometric parameters using swept-source optical coherence tomography(SS-OCT)and Scheimpflug tomography in patients diagnosed with catarac... AIM:To assess and compare the variations and agreements across different ocular biometric parameters using swept-source optical coherence tomography(SS-OCT)and Scheimpflug tomography in patients diagnosed with cataract.METHODS:This prospective case series was conducted at Tianjin Medical University Eye Hospital.In total,212 eyes from 212 patients scheduled for phacoemulsification were included.Eyes were evaluated preoperatively using two SSOCT devices(IOLMaster700 and CASIA2)and Scheimpflug tomography(Pentacam).Central corneal thickness(CCT),anterior chamber depth(ACD),aqueous depth(AQD),white-to-white distance(WTW),flat simulated keratometry(Kf),steep simulated keratometry(Ks),mean keratometry(Km),and total corneal keratometry(TKm)were measured.Intraclass correlation coefficient(ICC),95%confidence intervals(CI)and limits of agreement(LoA)widths were conducted to assess differences and correlations between devices.RESULTS:All parameters,except for Ks,were significantly different.Pairwise comparison revealed no significant differences between keratometry obtained by IOLMaster 700 and Pentacam.LoA widths of all paired comparisons for Ks were>0.80 D.Except for WTW between IOLMaster 700 and CASIA2 and between CASIA2 and Pentacam,other Pearson’s coefficients between devices showed a strong correlation(all r>0.95).The ICC of WTW(ICC=0.438,95%CI 0.167-0.625)showed poor reliability.The reliability of CCT,ACD,and AQD was excellent(all ICC>0.95),whereas that of TKm was good(ICC=0.827,95%CI 0.221-0.939).A significant linear correlation was also observed among devices.CONCLUSION:The ocular parameters derived from the use of IOLMaster700,CASIA2,and Pentacam exhibit significant discrepancies;as such,measurements from these devices should not be deemed as interchangeable. 展开更多
关键词 ocular parameters swept-source optical coherence tomography CATARACT
下载PDF
Rim^(18)F-fluorodeoxyglucose uptake of hepatic cavernous hemangioma on positron emission tomography/computed tomography:A case report
19
作者 Yong-An Hu Ya-Xin Guo Qi-Feng Huang 《World Journal of Clinical Cases》 SCIE 2024年第13期2243-2247,共5页
BACKGROUND Peripheral FDG accumulation in a hepatic hemangioma presenting in a patient with prolonged fever is rare.Therefore,clinicians should pay close attention to patients with hepatic mass.CASE SUMMARY A 54-year-... BACKGROUND Peripheral FDG accumulation in a hepatic hemangioma presenting in a patient with prolonged fever is rare.Therefore,clinicians should pay close attention to patients with hepatic mass.CASE SUMMARY A 54-year-old woman with a 4-wk history of daily fevers was admitted to our hospital.A whole body^(18)-Fluordesoxyglucose(PET-FDG)positron emission tomography/computed tomography(PET/CT)was performed to elucidate the source of the fever.However,whole body^(18)-FDG PET/CT raised the suspicion of a malignant lesion because of peripheral FDG accumulation(SUVmax 3.5 g/mL)higher than that of the normal liver parenchyma(SUVmax 1.6 g/mL)surrounding a hypoactive area,and no other abnormalities were showed.Subsequently,the patient underwent liver mass resection.Histopathology showed a hepatic cavernous hemangioma with fatty infiltration around the lesion.The fever disappeared four days after surgery and the patient did not present any complications during follow-up.CONCLUSION Fatty infiltration in the peripheral parts of hepatic cavernous hemangioma may lead to subacute inflammation which further activate the Kupffer cells.This may cause prolonged fever and peripheral rim FDG accumulation on PET/CT. 展开更多
关键词 ^(18)-Fluordesoxyglucose positron emission tomography/computed tomography Hepatocellular carcinoma FEVER Fatty infiltration Case report
下载PDF
Deep learning-based inpainting of saturation artifacts in optical coherence tomography images
20
作者 Muyun Hu Zhuoqun Yuan +2 位作者 Di Yang Jingzhu Zhao Yanmei Liang 《Journal of Innovative Optical Health Sciences》 SCIE EI CSCD 2024年第3期1-10,共10页
Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts ... Limited by the dynamic range of the detector,saturation artifacts usually occur in optical coherence tomography(OCT)imaging for high scattering media.The available methods are difficult to remove saturation artifacts and restore texture completely in OCT images.We proposed a deep learning-based inpainting method of saturation artifacts in this paper.The generation mechanism of saturation artifacts was analyzed,and experimental and simulated datasets were built based on the mechanism.Enhanced super-resolution generative adversarial networks were trained by the clear–saturated phantom image pairs.The perfect reconstructed results of experimental zebrafish and thyroid OCT images proved its feasibility,strong generalization,and robustness. 展开更多
关键词 Optical coherence tomography saturation artifacts deep learning image inpainting.
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部