期刊文献+
共找到577篇文章
< 1 2 29 >
每页显示 20 50 100
Systematic Analysis of the ArcCheck Diode Arrays for Tomotherapy Delivery Verification 被引量:2
1
作者 Qi Yue Jimei Duan +1 位作者 Rongqing Li Jack Yang 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2014年第4期218-225,共8页
Objective: The aim of this study was to evaluate the functional characteristics of ArcCheck? array detectors and the application for Tomotherapy IMRT plan verification. Method and Materials: The basic character of the... Objective: The aim of this study was to evaluate the functional characteristics of ArcCheck? array detectors and the application for Tomotherapy IMRT plan verification. Method and Materials: The basic character of the ArcCheck applying on Tomotherapy system was tested. The diode testing procedures included the followings: The short term reproducibility, linearity, dose rate dependence, the profile measurement compared to ion chamber. The effect of insert on gamma passing rate was also studied. A total number of 602 Tomotherapy Delivery Quality Assurance (DQA) plans were retrospectively analyzed to obtain the action limit results with statistical significance evaluation. Results: The short term reproducibility, linearity, dose rate dependence, profile to ion chamber correlation and clinical application were all compared with satisfactory outcome with this device. If anterior diode points were properly calibrated with machine absolute output, then there was no significant difference between the ArcCheck phantom with and without insert on gamma passing rate. The average passing rate was 97.5% and the recommend action level was established at 92% based on the 602 patients’ clinical data with 95% confidence level criteria. Conclusion: This comprehensive study shows that ArcCheck is an accurate and efficient device for quality assurance of Tomotherapy with remarkable consistency of 3D volume analysis of arc therapy. 展开更多
关键词 ArcCheck GAMMA PASSING RATE tomotherapy
下载PDF
基于Tomo-PIV技术的螺旋桨三维强旋转流动的实验研究
2
作者 曾子扬 余志强 +2 位作者 方兆波 季志伟 单峰 《大电机技术》 2024年第1期91-98,共8页
流体机械以及水力发电过程中的流动通常是具有强旋流的三维空间流动,此类流动的实验测量具有较大的难度。本文以水下伺服电机搭载三叶螺旋桨产生强的三维强旋转流动为例,采用四台CMOS摄像机同步对流场进行拍摄,并利用搭载了目前国际上... 流体机械以及水力发电过程中的流动通常是具有强旋流的三维空间流动,此类流动的实验测量具有较大的难度。本文以水下伺服电机搭载三叶螺旋桨产生强的三维强旋转流动为例,采用四台CMOS摄像机同步对流场进行拍摄,并利用搭载了目前国际上最先进的层析粒子图像测速技术(Tomo-PIV)算法的德国LaVision公司的软件Davis 10.2.0对拍摄得到的图像进行空间重构,得到瞬时的三维空间速度场。基于得到的速度场,对螺旋桨三维强旋流结构的瞬时特性和时均特性进行了深入分析,并从速度、涡量和压力的变化上阐述了流场结构变化特点,证明了Tomo-PIV技术具有很高的测量精度和实际应用意义,在流体机械流场测量和水力发电领域三维空间流场的精细测量有广阔的应用前景。 展开更多
关键词 层析粒子图像测速技术(tomo-PIV) 螺旋桨射流 三维速度场 流体机械流场测量
下载PDF
Hi-Art tomotherapy加速器机房的辐射防护屏蔽评价 被引量:3
3
作者 刘海宽 吴锦海 +4 位作者 顾乃谷 高佚名 王力 黄卫琴 王凤仙 《核技术》 CAS CSCD 北大核心 2010年第10期771-774,共4页
利用Hi-Art tomotherapy加速器辐射场的数据,来计算某医院同型加速器机房防护屏蔽厚度,并进行职业病危害辐射防护评价。由于螺旋断层加速器自屏蔽结构的存在,对于其机房屏蔽防护设计只需考虑散射线和漏射线。根据同型加速器辐射场特性,... 利用Hi-Art tomotherapy加速器辐射场的数据,来计算某医院同型加速器机房防护屏蔽厚度,并进行职业病危害辐射防护评价。由于螺旋断层加速器自屏蔽结构的存在,对于其机房屏蔽防护设计只需考虑散射线和漏射线。根据同型加速器辐射场特性,计算以加速器中心点为中心、每隔15o张角所对应机房墙体辐射防护屏蔽厚度,并对机房的设计值进行对比评价。结果表明,机房各屏蔽体所需防护屏蔽厚度最大值为与加速器中心点张角为15o处,东、南、西、北面墙体、顶棚、地板所需屏蔽厚度分别为1023、975、917、1460、1147和1189mm。经核实计算,除北侧防护墙设计厚度(1200mm)偏小外,其余均满足辐射防护屏蔽的要求。 展开更多
关键词 Hi-Art tomotherapy加速器 屏蔽计算 防护评价
下载PDF
TomoTherapy治疗计划剂量验证方法的研究 被引量:2
4
作者 赵进沛 张富利 +2 位作者 王雅棣 李秀芹 杨新芳 《医疗卫生装备》 CAS 2013年第7期105-107,共3页
目的:建立一种可以对TomoTherapy治疗计划剂量进行验证的方法。方法:根据IAEA TRS 277号报告提供的水下吸收剂量测量计算的基本原理,采用待检的TomoTherapy辐射源以及在权威计量部门检定过的0.65 cc Farmer电离室,参照交叉校准的方法将... 目的:建立一种可以对TomoTherapy治疗计划剂量进行验证的方法。方法:根据IAEA TRS 277号报告提供的水下吸收剂量测量计算的基本原理,采用待检的TomoTherapy辐射源以及在权威计量部门检定过的0.65 cc Farmer电离室,参照交叉校准的方法将标准量值传递给0.015 cc针尖电离室测量系统。之后采用固体水球型模体对治疗计划剂量进行检测和验证。结果:采用所建立的方法,剂量检测结果与治疗计划剂量相对偏差分别为1.35%、-2.30%、2.88%和0,皆小于±3%。结论:采用本研究所建立的方法可以与设备生产厂家的剂量治疗计划、检测结果进行比对、核查和控制,对于TomoTherapy项目的防护与应用质量检测具有重要的现实意义。 展开更多
关键词 tomotherapy 剂量 治疗计划系统 测量
下载PDF
TomoTherapy在全身放疗方面的应用 被引量:4
5
作者 岳麒 段继梅 +5 位作者 王志伟 谷丹 杨秀美 杨红波 张燕华 李荣清 《中国医学物理学杂志》 CSCD 2012年第5期3606-3609,共4页
目的:本文报道一例TomoTherapy全身照射病例,介绍其调强计划方案,并分析其计划及验证结果。方法:由定位CT获取病人全身CT图像,在CMS医生工作站进行靶区和重要器官的勾画,传至TomoTherapy计划工作站进行计划设计。用ArcCheck三维半导体... 目的:本文报道一例TomoTherapy全身照射病例,介绍其调强计划方案,并分析其计划及验证结果。方法:由定位CT获取病人全身CT图像,在CMS医生工作站进行靶区和重要器官的勾画,传至TomoTherapy计划工作站进行计划设计。用ArcCheck三维半导体矩阵对计划实施验证,计划验证通过后在螺旋断层放疗设备上完成对病人的全身照射。结果:85%的靶区接受10Gy的处方剂量,靶区适形度CI和均匀指数HI分别为0.76和1.16。重要器官限制剂量达到临床要求,左晶体的最大剂量为3.4Gy,右晶体的最大剂量为4.3Gy,肺的平均剂量为5.5Gy,V5为45%,左肾的平均剂量为5Gy,右肾的平均剂量为5.7Gy。结论:TomoTherapy可以完成全身的照射,肺的剂量可以降得更低,减少毒副反应。为全身放疗提供了一种安全的方法。 展开更多
关键词 tomotherapy 全身照射 剂量验证
下载PDF
Tomotherapy系统五年质控结果及其模式的转变 被引量:5
6
作者 丛小虎 徐寿平 +3 位作者 解传滨 戴相昆 巩汉顺 王小深 《中国医疗器械杂志》 2016年第5期380-385,共6页
螺旋断层治疗(Helical Tomotherapy,HT)作为新型调强放射治疗技术(IMRT),其照射方式采用独特的扇形束形式,将现代螺旋CT和直线加速器进行有机整合以实现螺旋断层调强治疗。由于该系统功能复杂,且具有高度集成和自动化特性,监测其运行稳... 螺旋断层治疗(Helical Tomotherapy,HT)作为新型调强放射治疗技术(IMRT),其照射方式采用独特的扇形束形式,将现代螺旋CT和直线加速器进行有机整合以实现螺旋断层调强治疗。由于该系统功能复杂,且具有高度集成和自动化特性,监测其运行稳定性和可靠性并不断给予完善、简化其质控流程已成为HT系统质量保证的重要组成部分。本研究通过对前五年该系统质量控制(QC)结果的分析,结合新型质控设备的初步应用,总结其QA的规范化实施并探讨其模式的转变可能。 展开更多
关键词 螺旋断层治疗 质量保证(QA) 质量控制(QC) 模式转变
下载PDF
TOMOTHERAPY螺旋断层放射治疗的现状与应用前景 被引量:14
7
作者 尚进 李东 《中国医疗设备》 2012年第2期48-50,共3页
本文以Wisconsin大学Madison医院开发的螺旋断层治疗技术为依据介绍螺旋断层治疗系统,阐述了螺旋断层放射治疗在以图像引导为特征的肿瘤放疗中的重要地位和发展前景。
关键词 螺旋断层放射治疗 放射治疗 图像引导
下载PDF
TomoTherapy HI-ART加速器剂量输出稳定性检测与评价 被引量:2
8
作者 管秋 杨波 +3 位作者 王欣海 李文博 李楠 邱杰 《协和医学杂志》 2013年第4期404-407,共4页
目的对TomoTherapy HI-ART加速器剂量输出的稳定性进行检测和评价。方法利用A1SL电离室、矩形固体水模体与圆柱形固体水模体,参照美国医学物理学会TG-148号报告,对TomoTherapy HI-ART加速器质控规程中静态剂量输出、动态剂量输出、射线... 目的对TomoTherapy HI-ART加速器剂量输出的稳定性进行检测和评价。方法利用A1SL电离室、矩形固体水模体与圆柱形固体水模体,参照美国医学物理学会TG-148号报告,对TomoTherapy HI-ART加速器质控规程中静态剂量输出、动态剂量输出、射线质稳定性进行检测,并对结果进行分析。结果静态剂量输出结果偏差平均值为(-0.6±1.1)%,有89.1%的数据在±2%的允许偏差范围之内,数据分布无明显规律。动态剂量输出结果偏差平均值为(1.0±1.1)%,有87.1%的数据在±2%的允许偏差范围之内。射线质较为稳定,偏差平均值为(-0.01±1.26)%,80%的结果在±1%的偏差范围之内,96%的结果在±2%的允许偏差范围之内。结论 TomoTherapy HI-ART加速器剂量输出稳定性略低于常规加速器,剂量输出易发生波动,因此每日对其输出量进行系统检测十分重要。 展开更多
关键词 螺旋断层调强放疗 剂量输出 质量控制
下载PDF
Tomotherapy HDA型螺旋断层调强放疗设备剂量传输方式的质控标准建立 被引量:2
9
作者 庞廷田 于浪 +5 位作者 杨波 刘峡 刘楠 李文博 董婷婷 邱杰 《中国医疗设备》 2022年第1期20-24,共5页
目的通过对本单位新装Tomotherapy HDA的两种调强传输方式的剂量验证结果进行测量分析,确定质控结果的合理范围,为质控工作提供依据。方法依照AAPM TG119要求对其提供的病例制作调强治疗计划,每种病例根据传输方式、铅门大小和运动方式... 目的通过对本单位新装Tomotherapy HDA的两种调强传输方式的剂量验证结果进行测量分析,确定质控结果的合理范围,为质控工作提供依据。方法依照AAPM TG119要求对其提供的病例制作调强治疗计划,每种病例根据传输方式、铅门大小和运动方式分别制作计划,共95例调强计划,分别测量点剂量100例,面剂量45例,分析实际测量结果,并分别计算不同调强传输类型计划的置信区间。结果 Tomo-Helical传输模式靶区点剂量测量置信区间为±2.43%,危及器官点剂量验证置信区间为±1.46%。Tomo-Direct模式靶区点剂量验证置信区间为±2.72%,危及器官点剂量验证置信区间为±2.66%。面剂量验证结果为:Tomo-Helical模式通过率≥97.9%,Tomo-Direct通过率≥96.9%。结论本研究对本单位新安装的Tomotherapy HDA新型螺旋断层调强治疗进行测试,所测参数置信区间均在报告推荐范围之内,为新的螺旋断层调强技术和日后调强治疗计划的质控提供了依据。 展开更多
关键词 螺旋断层调强放射治疗 调强计划验证 Gamma分析 置信区间
下载PDF
TomoTherapy HT系统长期剂量及能量稳定性监测
10
作者 杨秀美 段继梅 +2 位作者 岳麒 王志伟 谷丹 《中国医疗设备》 2018年第7期85-87,共3页
目的对Tomothepapy HT系统剂量及能量稳定性进行监测与评价,研究更换系统重要部件对剂量及能量稳定性的影响。方法用A1SL电离室,Tomo Electronmeter矩形固体水模体,参照美国医学物理学会TG-148号报告,对Tomotherapy HT系统质控规程中剂... 目的对Tomothepapy HT系统剂量及能量稳定性进行监测与评价,研究更换系统重要部件对剂量及能量稳定性的影响。方法用A1SL电离室,Tomo Electronmeter矩形固体水模体,参照美国医学物理学会TG-148号报告,对Tomotherapy HT系统质控规程中剂量输出、能量稳定性进行长期监测,并收集整理数据及分析结果。数据囊括了2011年3月到2017年3月所有日检剂量输出结果和月检静态模式下束流能量稳定性测量结果。结果 6年日检剂量输出平均绝对偏差是1.2%,更换固定靶前后绝对偏差值分别是1.30%、1.30%(P=0.986)。系统安装剂量伺服系统(Dose Servo System,DCS)前后偏差均值分别为1.30%、0.96%(P<0.001)。6年能量稳定性监测(ratio_P20/P10)平均绝对偏差是0.82%。更换固定靶前后平均偏差分别是0.82%、1.11%(P=0.248)。安装DCS前后绝对偏差是1.11%、0.64%(P=0.088)。结论 Tomo Therapy HT系统长期剂量和能量稳定性较好。固定靶与旋转靶对输出剂量和能量稳定性影响均无差异。剂量伺服系统的安装提高了输出剂量的稳定性而对能量稳定性无影响。 展开更多
关键词 tomotherapy HT 剂量输出 旋转靶 固定靶 剂量伺服系统
下载PDF
Tomotherapy计划系统中利用不同密度模体精确创建CT值密度曲线
11
作者 庞廷田 杨波 +5 位作者 于浪 刘峡 刘楠 李文博 董婷婷 邱杰 《中国医疗设备》 2022年第2期29-34,共6页
目的通过研究不同密度模体创建的CT值密度曲线(Image Value to Density Table,IVDT)对剂量计算精度的影响,探讨如何在Tomotherapy计划系统中正确创建IVDT。方法分别用Gammex和CIRS两种密度模体创建立应的IVDT表,其中以是否含有空气密度... 目的通过研究不同密度模体创建的CT值密度曲线(Image Value to Density Table,IVDT)对剂量计算精度的影响,探讨如何在Tomotherapy计划系统中正确创建IVDT。方法分别用Gammex和CIRS两种密度模体创建立应的IVDT表,其中以是否含有空气密度点和在CT值-100~100 HU范围内是否包含除水以外的物质密度点分别创建IVDT表。调用不同IVDT表设计4组调强计划,同时生成7组剂量传输验证计划(Delivery Quality Assurance,DQA),测量上述11组调强计划的剂量偏差并进行配对t检验判断IVDT表是否符合要求。结果IVDT表中含有-100~100 HU计划组剂量偏差为1.55%±0.9%,与标准计划组剂量偏差比,有统计学差异(P<0.01),同理,不含空气密度点组的剂量偏差也有明显剂量学差异。7组DQA计划中调用CIRS IVDT Abdo(-100~100 HU)、Gammex IVDT Abdo(standard)的5组DQA计划剂量偏差,无统计学差异(P>0.05);调用CIRS IVDT Abdo(-100~100 HU)的2组DQA计划平均剂量偏差均为1.77%±1%,与对照组剂量偏差相比,有统计学差异。结论创建IVDT表时需要确保CT值在-100~100 HU范围内除水以外不含任何其他物质密度点,同时曲线中应该加入空气密度点,此两点对剂量计算精度影响较大。 展开更多
关键词 tomotherapy计划治疗系统 CT值密度曲线 剂量传输验证计划 剂量偏差
下载PDF
TQA数据趋势与TomoTherapy输出稳定性的联系
12
作者 陈济鸿 张秀春 +6 位作者 柏朋刚 陆军 陈文娟 陈开强 李奇欣 胡彩容 林金勇 《中国医学物理学杂志》 CSCD 2020年第9期1120-1123,共4页
目的:探讨TomoTherapy QualityAssurance(TQA)数据趋势与螺旋断层放疗(Helical Tomotherapy,HT)系统输出的联系。方法:回顾性分析了本院HT系统近3年内TQA各个模块的参数和数据趋势,探讨其与HT系统的静态输出剂量和输出能量(D20/D10)变... 目的:探讨TomoTherapy QualityAssurance(TQA)数据趋势与螺旋断层放疗(Helical Tomotherapy,HT)系统输出的联系。方法:回顾性分析了本院HT系统近3年内TQA各个模块的参数和数据趋势,探讨其与HT系统的静态输出剂量和输出能量(D20/D10)变化的相关性。结果:楔形阶梯静态模块的z轴偏移参数与HT的静态输出剂量的相关性最强(r=0.883,P<0.01)。基本剂量测定模块的出口检测器平整度值对能量变化最敏感(r=0.902),其次是楔形阶梯静态模块的能量差异(r=0.897)和楔形阶梯螺旋模块的能量差异(r=0.852),灵敏度分别为2.3×10^-4、3.1×10^-4和5.7×10^-4。结论:TQA有助于用户追踪HT输出剂量和能量变化,及早进行必要的机器维护或剂量校准。 展开更多
关键词 螺旋断层放疗 TQA 静态输出剂量 射线质
下载PDF
质子点扫描技术与光子Tomotherapy在前列腺癌应用中的剂量学比较
13
作者 徐伟 杨涛 +6 位作者 解传滨 曲宝林 曹林 王子申 宋圆圆 方春锋 徐寿平 《中国医学物理学杂志》 CSCD 2019年第10期1129-1133,共5页
目的:比较前列腺癌质子点扫描技术(SSS-PT)与光子螺旋断层放射治疗(HT)两者之间的剂量学特点,其数据将为临床提供一定的参考。方法:选取12例既往前列腺癌患者作为研究对象,定位后,将CT图像分别传至Raystation和HT计划系统进行放疗计划... 目的:比较前列腺癌质子点扫描技术(SSS-PT)与光子螺旋断层放射治疗(HT)两者之间的剂量学特点,其数据将为临床提供一定的参考。方法:选取12例既往前列腺癌患者作为研究对象,定位后,将CT图像分别传至Raystation和HT计划系统进行放疗计划设计。处方剂量为69Gy/25F。比较分析两种放疗计划的靶区适形度指数(CI)、均匀性指数(HI)、靶区和危及器官剂量学参数。结果:靶区的均匀性方面,SSS-PT优于HT(P=0.001);直肠平均剂量SSS-PT[(21.92±4.00)Gy]低于HT[(31.97±2.60)Gy](P=0.000);膀胱平均剂量SSS-PT[(17.62±3.15)Gy]低于HT[(30.52±3.94)Gy](P=0.000);对于直肠和膀胱的保护,SSS-PT在低、中剂量区总是优于HT。结论:SSS-PT和HT两种治疗方式在靶区剂量分布均可满足临床需求,在同样靶区覆盖条件下,SSS-PT相较于HT能够更好地保护直肠和膀胱,尤其是在低、中剂量区。 展开更多
关键词 前列腺癌 质子放疗 点扫描技术 螺旋断层放射治疗 剂量学
下载PDF
TomoTherapy HD放射治疗系统的温度控制系统工作原理及故障分析
14
作者 王倩倩 段诗苗 崔宏伟 《医疗装备》 2022年第15期131-132,134,共3页
TomoTherapy HD放射治疗系统的产热部件包括加速管、磁控管、固态调制器、高压电源、微波循环控制器等[1-2]。这些部件只有在恒温条件下才能保证稳定工作。因此,温度控制系统(themal control system,TCS)是TomoTherapy HD放射治疗系统... TomoTherapy HD放射治疗系统的产热部件包括加速管、磁控管、固态调制器、高压电源、微波循环控制器等[1-2]。这些部件只有在恒温条件下才能保证稳定工作。因此,温度控制系统(themal control system,TCS)是TomoTherapy HD放射治疗系统的重要组成部分,其稳定性直接影响着射频和束流部件的寿命及整机系统的故障率。本文首先介绍TomoTherapy HD放射治疗系统的TCS工作原理,然后对TCS的常见故障及维修过程进行总结,以供参考。 展开更多
关键词 tomotherapy HD放射治疗系统 温度控制系统 故障分析
下载PDF
Clinical analysis of intracranial germinoma's craniospinal irradiation using helical tomotherapy 被引量:14
15
作者 Baolin Qu Lei Du +4 位作者 Yurong Huang Wei Yu Boning Cai Shouping Xu Lin Ma 《Chinese Journal of Cancer Research》 SCIE CAS CSCD 2014年第3期247-254,共8页
Objective: To evaluate the short-term clinical outcomes of intracranial germinoma patients treated with craniospinal irradiation (CSI) using helical tomotherapy (HT) system in our center. Methods: Twenty-three p... Objective: To evaluate the short-term clinical outcomes of intracranial germinoma patients treated with craniospinal irradiation (CSI) using helical tomotherapy (HT) system in our center. Methods: Twenty-three patients who were treated with CSI in our center from January 2008 to July 2012 were collected, with an average age of 20. M1 of the patients' CSI used the HT system. The total doses were 27-36 Gy/15-20 F (1.5-2 Gy per fraction), and total local doses were 46-60 Gy/30-50 F (5 fractions per week). M1 female patients for CSI were treated with left-right parallel-opposed field irradiation to protect their ovarian functions. Median follow-up time was 30.9 months (range, 5-67 months). The SPSS19.0 software was used, and the overall survival (OS) was calculated using the Kaplan-Meier method. Results: Among 17 patients with assessable tumors, 9 cases (52.9%) were CR, 7 cases (41.2%) were PR, and 1 case (5.9%) was SD. Hematological toxicity was the severest side-effect occurred in the procedure of CSI. The level 1-4 acute leukopenia were 8.7%, 30.4%, 34.8% and 21.7% and the level 1-4 acute thrombopenia were 8.7%, 30.4%, 21.7% and 8.7%, respectively. Conclusions: For primary intracranial germinomas, HT can be used to implement CSI for simplifying radiotherapy procedures, improving radiotherapy accuracy, enhancing protection of peripheral organs at risk (ORA) and guaranteeing therapeutic effects. With the acceptable acute and long-term toxicity, CSI using HT in intracranial germinoma patients can be a safe and alternative mode. 展开更多
关键词 Germinomas craniospinal irradiation (CSI) helical tomotherapy (HT)
下载PDF
Could helical tomotherapy do whole brain radiotherapy and radiosurgery? 被引量:5
16
作者 Youlia M Kirova Cyrus Chargari +1 位作者 Sofia Zefkili Franois Campana 《World Journal of Radiology》 CAS 2010年第4期148-150,共3页
Whole brain radiotherapy (WBRT) remains the standard management of breast cancer patients with brain metastases, allowing for symptomatic improvement and good local control in most patients. However, its results remai... Whole brain radiotherapy (WBRT) remains the standard management of breast cancer patients with brain metastases, allowing for symptomatic improvement and good local control in most patients. However, its results remain suboptimal in terms of both efficacy and toxicity. In highly selected breast cancer patients, stereotaxic radiotherapy demonstrates a very good local control with a low toxicity. With the purpose of improving the efficacy/toxicity ratio, we report the association of integrated boost with WBRT in a breast cancer patient with brain metastases. Two and a half years after completion of helical tomotherapy (HT), the patient experienced clinical and radiological complete remission of her brain disease. No delayed toxicity occurred and the patient kept her hair without need of radiosurgical procedure. The HT provided a high dosimetric homogeneity, delivering integrated radiation boosts, and avoiding critical structures involved in long-term neurological toxicity. Further assessment is required and recruitment of breast cancer patients into clinical trials is encouraged. 展开更多
关键词 Brain METASTASES RADIOTHERAPY BREAST cancer tomotherapy
下载PDF
Dosimetric Comparison of Craniospinal Axis Irradiation (CSI) Treatments Using Helical Tomotherapy, Smartarc<sup>TM</sup>, and 3D Conventional Radiation Therapy 被引量:4
17
作者 Pamela Myers Sotirios Stathakis +3 位作者 Alonso N. Gutiérrez Carlos Esquivel Panayiotis Mavroidis Niko Papanikolaou 《International Journal of Medical Physics, Clinical Engineering and Radiation Oncology》 2013年第1期30-38,共9页
Purpose: Craniospinal axis irradiation (CSI) is a method of treating various central nervous system malignancies. The large target volume typically includes entire spinal cord and whole brain. Dosimetric comparison wa... Purpose: Craniospinal axis irradiation (CSI) is a method of treating various central nervous system malignancies. The large target volume typically includes entire spinal cord and whole brain. Dosimetric comparison was performed between tomotherapy, volumetric modulated arc therapy (VMAT), and 3D conformal radiation therapy (3D-CRT) for CSI. Methods and Materials: Five (n = 5) CSI patients were planned using 3D-CRT, VMAT, and tomotherapy (normalized such that 95% of PTV received at least 23.4 Gy in 13 fractions). Plans were compared using PTV conformity number (CN) and homogeneity index (HI), normal tissue (NT) dose statistics, integral dose, and treatment time. Results: On average, tomotherapy plans showed higher CN (0.932 vs. 0.860 and 0.672 for SmartArc and 3D-CRT). In terms of HI, VMAT plans consistently showed better dose homogeneity (1.07 vs. 1.15 and 1.13 for tomotherapy and 3D-CRT). SmartArc delivered lower maximum dose for majority of NT, but higher mean dose. 3D-CRT plans delivered higher maximum dose but lower mean dose to NT. Conclusions: SmartArc treatments achieved better PTV homogeneity and reduced maximum dose to NT. Tomotherapy showed better target conformity, but 3D-CRT was shown to reduce mean dose to NT. Integral doses were similar between treatment modalities, but tomotherapy treatment times were much longer. 展开更多
关键词 CSI tomotherapy SmartArc MEDULLOBLASTOMA
下载PDF
TomoTherapy Hi.Art放射治疗系统故障分析与排除 被引量:3
18
作者 李益坤 周彬 +1 位作者 曹晓卉 孙向东 《医疗卫生装备》 CAS 2020年第1期106-108,共3页
介绍了TomoTherapy Hi.Art放射治疗系统的基本组成及多叶光栅(multi-leaf collimator,MLC)的工作原理,详细分析了单片MLC故障、MLC初始化失败故障、MLC over travelled故障等产生的原因并给出了具体的排除方法,为同行维修类似故障提供... 介绍了TomoTherapy Hi.Art放射治疗系统的基本组成及多叶光栅(multi-leaf collimator,MLC)的工作原理,详细分析了单片MLC故障、MLC初始化失败故障、MLC over travelled故障等产生的原因并给出了具体的排除方法,为同行维修类似故障提供参考。 展开更多
关键词 tomotherapy Hi.Art放射治疗系统 多叶光栅 故障维修
下载PDF
Helical tomotherapy and volumetric modulated arc therapy:New therapeutic arms in the breast cancer radiotherapy 被引量:7
19
作者 Olivier Lauche Youlia M Kirova +8 位作者 Pascal Fenoglietto Emilie Costa Claire Lemanski Celine Bourgier Olivier Riou David Tiberi Francois Campana Alain Fourquet David Azria 《World Journal of Radiology》 CAS 2016年第8期735-742,共8页
AIM To analyse clinical and dosimetric results of helical tomotherapy(HT) and volumetric modulated arc therapy(VMAT) in complex adjuvant breast and nodes irradiation.METHODS Seventy-three patients were included(31 HT ... AIM To analyse clinical and dosimetric results of helical tomotherapy(HT) and volumetric modulated arc therapy(VMAT) in complex adjuvant breast and nodes irradiation.METHODS Seventy-three patients were included(31 HT and 42 VMAT). Dose were 63.8 Gy(HT) and 63.2 Gy(VMAT) in the tumour bed, 52.2 Gy in the breast, 50.4 Gy in supraclavicular nodes(SCN) and internal mammary chain(IMC) with HT and 52.2 Gy and 49.3 Gy in IMC and SCN with VMAT in 29 fractions. Margins to particle tracking velocimetry were greater in the VMAT cohort(7 mm vs 5 mm).RESULTS For the HT cohort, the coverage of clinical target volumes was as follows: Tumour bed: 99.4% ± 2.4%; breast: 98.4% ± 4.3%; SCN: 99.5% ± 1.2%; IMC:96.5% ± 13.9%. For the VMAT cohort, the coverage was as follows: Tumour bed: 99.7% ± 0.5%, breast: 99.3% ± 0.7%; SCN: 99.6% ± 1.4%; IMC: 99.3% ± 3%. For ipsilateral lung, Dmean and V20 were 13.6 ± 1.2 Gy, 21.1% ± 5%(HT) and 13.6 ± 1.4 Gy, 20.1% ± 3.2%(VMAT). Dmean and V30 of the heart were 7.4 ± 1.4 Gy, 1% ± 1%(HT) and 10.3 ± 4.2 Gy, 2.5% ± 3.9%(VMAT). For controlateral breast Dmean was 3.6 ± 0.2 Gy(HT) and 4.6 ± 0.9 Gy(VMAT). Acute skin toxicity grade 3 was 5% in the two cohorts.CONCLUSION HT and VMAT in complex adjuvant breast irradiation allow a good coverage of target volumes with an acceptable acute tolerance. A longer follow-up is needed to assess the impact of low doses to healthy tissues. 展开更多
关键词 Three-dimensional conformal radiotherapy Intensity modulated radiation therapy TOXICITY Helical tomotherapy Volumetric modulated arc therapy Breast cancer radiotherapy
下载PDF
Preliminary experience of helical tomotherapy for locally advanced pancreatic cancer 被引量:5
20
作者 Cyrus Chargari Francois Campana +2 位作者 Philippe Beuzeboc Sofia Zefkili Youlia M Kirova 《World Journal of Gastroenterology》 SCIE CAS CSCD 2009年第35期4444-4445,共2页
Radiotherapy for locally advanced pancreatic cancer is technically difficult and frequently associated with high-grade digestive toxicity.Helical tomotherapy(HT)is a new irradiation modality that combines megavoltage ... Radiotherapy for locally advanced pancreatic cancer is technically difficult and frequently associated with high-grade digestive toxicity.Helical tomotherapy(HT)is a new irradiation modality that combines megavoltage computed tomography imaging for patient positioning with intensity-modulated fan-beam radiotherapy.Its recent availability opens new fields of exploration for pancreatic radiotherapy as a result of its ability to tailor very well-defined dose distributions around the target volumes.Here,we report the use of HT in two patients with locally advanced pancreatic cancer. Doses to the bowel,kidneys and liver were reduced significantly,which allowed for excellent treatment tolerance without any high-grade adverse effects in either patient. 展开更多
关键词 胰腺癌 晚期 螺旋 放射治疗 剂量分布 消化系统 羟色胺 高档
下载PDF
上一页 1 2 29 下一页 到第
使用帮助 返回顶部