期刊文献+
共找到1,952篇文章
< 1 2 98 >
每页显示 20 50 100
Which approach of total hip arthroplasty is the best efficacy and least complication? 被引量:1
1
作者 Lertkong Nitiwarangkul Natthapong Hongku +3 位作者 Oraluck Pattanaprateep Sasivimol Rattanasiri Patarawan Woratanarat Ammarin Thakkinstian 《World Journal of Orthopedics》 2024年第1期73-93,共21页
BACKGROUND Total hip arthroplasty is as an effective intervention to relieve pain and improve hip function.Approaches of the hip have been exhaustively explored about pros and cons.The efficacy and the complications o... BACKGROUND Total hip arthroplasty is as an effective intervention to relieve pain and improve hip function.Approaches of the hip have been exhaustively explored about pros and cons.The efficacy and the complications of hip approaches remains inconclusive.This study conducted an umbrella review to systematically appraise previous meta-analysis(MAs)including conventional posterior approach(PA),and minimally invasive surgeries as the lateral approach(LA),direct anterior approach(DAA),2-incisions method,mini-lateral approach and the newest technique direct superior approach(DSA)or supercapsular percutaneouslyassisted total hip(SuperPath).AIM To compare the efficacy and complications of hip approaches that have been published in all MAs and randomized controlled trials(RCTs).METHODS MAs were identified from MEDLINE and Scopus from inception until 2023.RCTs were then updated from the latest MA to September 2023.This study included studies which compared hip approaches and reported at least one outcome such as Harris Hip Score(HHS),dislocation,intra-operative fracture,wound compliData were independently selected,extracted and assessed by two reviewers.Network MA and cluster rank and surface under the cumulative ranking curve(SUCRA)were estimated for treatment efficacy and safety.RESULTS Finally,twenty-eight MAs(40 RCTs),and 13 RCTs were retrieved.In total 47 RCTs were included for reanalysis.The results of corrected covered area showed high degree(13.80%).Among 47 RCTs,most of the studies were low risk of bias in part of random process and outcome reporting,while other domains were medium to high risk of bias.DAA significantly provided higher HHS at three months than PA[pooled unstandardized mean difference(USMD):3.49,95%confidence interval(CI):0.98,6.00 with SUCRA:85.9],followed by DSA/SuperPath(USMD:1.57,95%CI:-1.55,4.69 with SUCRA:57.6).All approaches had indifferent dislocation and intraoperative fracture rates.SUCRA comparing early functional outcome and composite complications(dislocation,intra-operative fracture,wound complication,and nerve injury)found DAA was the best approach followed by DSA/SuperPath.CONCLUSION DSA/SuperPath had better earlier functional outcome than PA,but still could not overcome the result of DAA.This technique might be the other preferred option with acceptable complications. 展开更多
关键词 total hip arthroplasty total hip replacement APPROACH Supercapsular percutaneously-assisted total hip Harris hip Score Intra-operative fracture
下载PDF
Intraoperative application of three-dimensional printed guides in total hip arthroplasty: A systematic review
2
作者 Tim P Crone Bart M W Cornelissen +2 位作者 Jakob Van Oldenrijk Pieter Koen Bos Ewout S Veltman 《World Journal of Orthopedics》 2024年第7期660-667,共8页
BACKGROUND Acetabular component positioning in total hip arthroplasty(THA)is of key importance to ensure satisfactory post-operative outcomes and to minimize the risk of complications.The majority of acetabular compon... BACKGROUND Acetabular component positioning in total hip arthroplasty(THA)is of key importance to ensure satisfactory post-operative outcomes and to minimize the risk of complications.The majority of acetabular components are aligned freehand,without the use of navigation methods.Patient specific instruments(PSI)and three-dimensional(3D)printing of THA placement guides are increasingly used in primary THA to ensure optimal positioning.AIM To summarize the literature on 3D printing in THA and how they improve acetabular component alignment.METHODS PubMed was used to identify and access scientific studies reporting on different 3D printing methods used in THA.Eight studies with 236 hips in 228 patients were included.The studies could be divided into two main categories;3D printed models and 3D printed guides.RESULTS 3D printing in THA helped improve preoperative cup size planning and post-operative Harris hip scores between intervention and control groups(P=0.019,P=0.009).Otherwise,outcome measures were heterogeneous and thus difficult to compare.The overarching consensus between the studies is that the use of 3D guidance tools can assist in improving THA cup positioning and reduce the need for revision THA and the associated costs.CONCLUSION The implementation of 3D printing and PSI for primary THA can significantly improve the positioning accuracy of the acetabular cup component and reduce the number of complications caused by malpositioning. 展开更多
关键词 total hip arthroplasty Three-dimensional printing hip replacement surgery Three-dimensional planning Surgical guides
下载PDF
Excision of trochanteric bursa during total hip replacement:Does it reduce the incidence of post-operative trochanteric bursitis?
3
作者 Wai-Huang Teng Adeel Ditta +1 位作者 Jane Webber Oliver Pearce 《World Journal of Orthopedics》 2023年第7期533-539,共7页
BACKGROUND Trochanteric bursitis is a common complication following total hip replacement(THR),and it is associated with high level of disability and poor quality of life.Excision of the trochanteric bursa prophylacti... BACKGROUND Trochanteric bursitis is a common complication following total hip replacement(THR),and it is associated with high level of disability and poor quality of life.Excision of the trochanteric bursa prophylactically during THR could reduce the occurrence of post-operative trochanteric bursitis.AIM To evaluate whether synchronous trochanteric bursectomy at the time of THR affects the incidence of post-operative trochanteric bursitis.METHODS This retrospective cohort study was conducted in the secondary care setting at a large district general hospital.Between January 2010 and December 2020,954 patients underwent elective primary THR by two contemporary arthroplasty surgeons,one excising the bursa and the other not(at the time of THR).All patients received the same post-operative rehabilitation and were followed up for 1 year.We reviewed all cases of trochanteric bursitis over this 11-year period to determine the incidence of post-THR bursitis.Two proportion Z-test was used to compare incidences of trochanteric bursitis between groups.RESULTS 554 patients underwent synchronous trochanteric bursectomy at the time of THR whereas 400 patients did not.A total of 5 patients(incidence 0.5%)developed trochanteric bursitis following THR;4 of whom had undergone bursectomy as part of their surgical approach,1 who had not.There was no statistically significant difference between the two groups(Z value 1.00,95%CI:-0.4%to 1.3%,P=0.32).There were also 8 other patients who had both trochanteric bursitis and hip osteoarthritis prior to their THR;all of whom were treated with THR and synchronous trochanteric bursectomy,and 7 had resolution of their lateral buttock pains but 1 did not.CONCLUSION Synchronous trochanteric bursectomy during THR does not materially affect the incidence of post-operative bursitis.However,it is successful at treating patients with known trochanteric bursitis and osteoarthritis requiring THR. 展开更多
关键词 total hip replacement Trochanteric bursectomy Trochanteric bursitis Greater trochanteric pain syndrome
下载PDF
Cementless Buechel-Pappas Resurfacing Total Hip Replacement: A 45-Year Personal Journey to Overcome Wear, Osteolysis, Loosening and Femoral Neck Fractures
4
作者 Frederick F. Buechel Sr 《Open Journal of Orthopedics》 2023年第10期435-442,共8页
Background: Resurfacing-type total hip replacement (THR) has been successfully developed over the past 50 years through collaborative efforts between engineers and surgeons. Much of the development was pursued by indi... Background: Resurfacing-type total hip replacement (THR) has been successfully developed over the past 50 years through collaborative efforts between engineers and surgeons. Much of the development was pursued by individuals or groups, each of which participated in adding further refinements to the implants, instruments and surgical procedures, thus minimizing the serious problems of wear, osteolysis, loosening and femoral neck fractures. The purpose of this study is to explore the development process to optimize the resurfacing total hip replacement into its current application. Methods: In the early 1980s, cementless resurfacing implants were developed using “thin shell” technology to minimize bony resection of the acetabulum and femoral head. Femoral components utilized short, non-porous coated, tapered straight stems to reduce shear stresses in the femoral neck to prevent fractures and stress shielding, while mechanically stabilizing and aligning the components. Acetabular components were anatomically designed to be recessed inside bony borders to avoid neck-cup impingement and loosening. Initially, ultrahigh molecular weight polyethylene (UHMWPE) was used as a bearing, but due to high levels of wear and osteolysis, it was replaced by wear-resistant highly crossed-linked polyethylene (HXLPE) in 2008. Results: Use of HXLPE as a bearing material in both Co-Cr-Mo and titanium nitride (TiN) ceramic-coated resurfacing implants has led to excellent patient outcomes for more than 10 years. In clinical studies, 87% of patients with bilateral total hip replacements prefer their resurfacing-type total hip over their stem-type total hip. The author’s own personal resurfacing total hips, now at 8 and 5 years, respectively, provide “normal” function and no radiographic osteolysis. Conclusions: After 45 years of active evaluation, including mechanical design considerations, prosthetic design development, clinical and radiographic analysis of results, as well as availability of components cleared by the FDA 510 K process, the author has stated a personal preference for the BP Resurfacing Hip System. His excellent mid-term results in both of his resurfaced hips are similar to the long-term results presented in published studies. 展开更多
关键词 Resurfacing total hip replacement
下载PDF
Total Hip Replacement in Young Adults Less Than Fifty Year Old: Our Experience
5
作者 Adonis Magoumou Narcisse Dabiré +9 位作者 Yassir El Andaloussi Said Abdallah Amine Belmoubarik Rachid Ait-Mouha Karim Ahed Nabil Omari Ahmed Reda Haddoun Driss Bennouna Mohamed Moujtahid Mohamed Nechad Mustapha Fadili 《Open Journal of Emergency Medicine》 2017年第2期43-74,共32页
Background: We report a retrospective study of 47 total prosthesis of hip put in place among the young adult of less than fifty years in the service of Traumatology and Orthopedics at the Wing IV of the CHU Ibn Rochd ... Background: We report a retrospective study of 47 total prosthesis of hip put in place among the young adult of less than fifty years in the service of Traumatology and Orthopedics at the Wing IV of the CHU Ibn Rochd of Casablanca, over a period from January 2008 to March 2014, with an average rate of decline of 42 months. Results: The deliberate group of 43 patients (47 hips including 4 bilateral) consisted of 26 women, either 60, 47% and 17 men, either 39, 53%. The average age of our patients was 36 years. In our series, the predominant etiology has been conducted for the indication of the hip replacement was the aseptic osteonecrosis of the femoral head which has represented 31.91%. With regards to the choice of implants, 85% of PTH were non-cemented, the cemented PTH has been used in 15% of cases. The Friction Torque metal/polyethylene was used in all cases. The functional outcome was appreciated by the rating of Merle of Aubigne before and after arthroplasty. The average rate of decline of 42 months, and the results were generally satisfactory. They were excellent in 27.78% of cases, very good in 19.44% of cases and good in 44.44% of cases. The results on the Pain were remarkable: the rating of the pain going 2.8 in pre-operative at 5.6 at the latest decline. The results on the walking and mobility were also good. It was noted as a complication: 4 cases of prosthetic dislocation, 1 case of aseptic descellement bipolar, 2 cases of early sepsis on hardware, 3 cases of paralysis of the sciatic external popliteal and 4 cases of periprothetiques ossification. In total, 5 total prosthesis of hip were occasions. The young age does not seem to be an obstacle to the prosthetic surgery. Conclusion: However, a major question remains concerning the distant future of these prostheses in young active subjects, because they will be submitted for many years in a job which can cause the descellement of prosthetic parts. 展开更多
关键词 total hip replacement YOUNG SUBJECTS hip Disease Casablanca
下载PDF
Total hip arthroplasty following the failure of intertrochanteric nailing:First implant or salvage surgery? 被引量:3
6
作者 Giuseppe Solarino Davide Bizzoca +4 位作者 Pasquale Dramisino Giovanni Vicenti Lorenzo Moretti Biagio Moretti Andrea Piazzolla 《World Journal of Orthopedics》 2023年第10期763-770,共8页
BACKGROUND Proximal femur fractures,including both intracapsular(femoral neck fractures)and extracapsular fractures(intertrochanteric femoral fractures,IFFs),affect around 1.5 million people per year worldwide.Mechani... BACKGROUND Proximal femur fractures,including both intracapsular(femoral neck fractures)and extracapsular fractures(intertrochanteric femoral fractures,IFFs),affect around 1.5 million people per year worldwide.Mechanical failures of intertrochanteric nailing in IFFs could be managed with revision total hip arthroplasty(THA).AIM To describe the surgical complexity and the procedure-related complication rates in patients with trochanteric nailing failure and treated with THA.METHODS Patients referred to our level I trauma center between April 2012 and July 2018 with failed cephalomedullary nailing following trochanteric fractures were retrospectively recruited.All patients underwent a salvage surgical procedure,i.e.,cephalomedullary nail removal and conversion to THA.The same surgical and anesthesiology team performed the surgical procedures under spinal anesthesia.All patients underwent clinical and radiographic follow-ups for at least 24 mo.Complications and re-operations were recorded.RESULTS Seventy-four patients met the inclusion criteria(male:29;female:45;mean age:73.8-years-old;range:65-89)and were included in the current study.The average operative time was 117 min(76-192 min).The average blood loss was 585 mL(430-1720 mL).Among the 74 patients,43(58.1%)required transfusion of three or more blood units.Two patients died within the 4th d after surgery because of pulmonary embolism,and 1 patient died 9 mo after surgery due to ischemic myocardial infarction.The complication rate in the 71 patients who completed the minimum 24-mo follow-up was 22.5%.In 3 cases out of 71(4.2%)periprosthetic acetabular fracture was observed during the followup.One of these periacetabular fractures occurred intraoperatively.An intraoperative periprosthetic femur fracture was observed in 5 patients out of 71(7.0%).Four of these patients needed a re-operation to fix the fracture with plates and cerclages;in one of these patients,femoral stem revision was also necessary.In 4 patients out of 71(5.6%),an early THA dislocation was observed,whereas in 1 case(1.4%)a late THA dislocation was observed.Three patients out of 71(4.2%)developed a periprosthetic joint infection during the study follow-up.CONCLUSION The present study demonstrated that salvage options for IFF fixation failure are complex procedures with a relevant intraoperative and postoperative complication rate. 展开更多
关键词 Femoral nailing total hip arthroplasty Proximal femur fractures OSTEOPOROSIS Fragility fractures Geriatric patients hip traumatology hip replacement
下载PDF
Total hip replacement for arthritis following tuberculosis of hip 被引量:21
7
作者 Vijay Kumar Bhavuk Garg Rajesh Malhotra 《World Journal of Orthopedics》 2015年第8期636-640,共5页
AIM: To present the results of total hip arthroplasty(THA) for post tubercular arthritis of the hip joint.METHODS: Sixty-five patients(45 male, 20 female) with previously treated tuberculosis of the hip joint underwen... AIM: To present the results of total hip arthroplasty(THA) for post tubercular arthritis of the hip joint.METHODS: Sixty-five patients(45 male, 20 female) with previously treated tuberculosis of the hip joint underwent cementless THA for post tubercular arthritis. The average age at the time of THA was 48 years(range 29 to 65 years). Erythrocyte sedimentation rate, C reactive protein, chest X-ray and contrast enhanced magnetic resonance imaging were done preoperatively to confirm resolution of the disease and to rule out any residual disease. Intra-operative samples were taken for microbiological examination, polymerase chain reaction(PCR) and histological examination. Patients were started on anti-tubercular drugs one week before the operation and continued for 6 mo post operatively. The patients were followed up clinically using the Harris hip score as well as radiologically for any loosening of the implants, osteolysis and any recurrence of tuberculosis. Any complications especially the recurrence of the infection was also recorded.RESULTS: The mean interval from completion of antitubercular therapy for tuberculosis to surgery was 4.2 years(range, 2-6 years). Preoperatively, 17 patients had ankylosis whereas 48 patients had functional but painful range of motion. The mean surgical time was 97 min(range, 65-125) whereas the mean blood loss was 600 m L(range, 400-900 m L). The average follow up was 8.3 years(range 6-11 years). The average Harris Hip score improved from 27 preoperatively to 91 at the final follow up. Seventeen patients had acetabularprotrusion which was managed with impaction grafting and cementless acetabular cup. The bone graft had consolidated in all these 17 patients at the follow up. Two patients developed discharging sinuses at 9 and 11 mo postoperatively respectively. The discharge tested positive for tuberculosis on the PCR. Both these patients were put on antitubercular therapy for another year. Both of them recovered and had no evidence of any loosening or osteolysis on X-rays. There were no other complications recorded.CONCLUSION: Total hip replacement restores good function to patients suffering from post tubercular arthritis of the hip. 展开更多
关键词 total hip replacement CEMENTLESS hip replacement TUBERCULOSIS hip Post-tubercular ARTHRITIS hip total hip arthroplasty
下载PDF
Total hip replacement:A meta-analysis to evaluate survival of cemented,cementless and hybrid implants 被引量:10
8
作者 Phedy Phedy H Dilogo Ismail +1 位作者 Charles Hoo Yoshi P Djaja 《World Journal of Orthopedics》 2017年第2期192-207,共16页
AIM To determine whether cemented, cementless, or hybrid implant was superior to the other in terms of survival rate.METHODS Systematic searches across MEDLINE, CINAHL, and Cochrane that compared cemented, cementless ... AIM To determine whether cemented, cementless, or hybrid implant was superior to the other in terms of survival rate.METHODS Systematic searches across MEDLINE, CINAHL, and Cochrane that compared cemented, cementless and hybrid total hip replacement(THR) were performed. Two independent reviewers evaluated the risk ratios of revision due to any cause, aseptic loosening, infection, and dislocation rate of each implants with a pre-determined form. The risk ratios were pooled separately for clinical trials, cohorts and registers before pooled altogether using fixed-effect model. Meta-regressions were performed to identify the source of heterogeneity. Funnel plots were analyzed. RESULTS Twenty-seven studies comprising 5 clinical trials, 9 cohorts, and 13 registers fulfilled the research criteria and analyzed. Compared to cementless THR, cemented THR have pooled RR of 0.47(95%CI: 0.45-0.48), 0.9(0.84-0.95), 1.29(1.06-1.57) and 0.69(0.6-0.79) for revision due to any reason, revision due to aseptic loosening, revision due to infection, and dislocation respectively. Compared to hybrid THR, the pooled RRs of cemented THR were 0.82(0.76-0.89), 2.65(1.14-6.17), 0.98(0.7-1.38), and 0.67(0.57-0.79) respectively. Compared to hybrid THR, cementless THR had RRs of 0.7(0.65-0.75), 0.85(0.49-1.5), 1.47(0.93-2.34) and 1.13(0.98-1.3).CONCLUSION Despite the limitations in this study, there was some tendency that cemented fixation was still superior than other types of fixation in terms of implant survival. 展开更多
关键词 total hip replacement IMPLANT SURVIVAL CEMENTED CEMENTLESS HYBRID META-ANALYSIS
下载PDF
Survival outcomes of cemented compared to uncemented stems in primary total hip replacement 被引量:4
9
作者 Michael Wyatt Gary Hooper +1 位作者 Christopher Frampton Alastair Rothwell 《World Journal of Orthopedics》 2014年第5期591-596,共6页
Total hip replacement(THR) is a successful and reliable operation for both relieving pain and improving function in patients who are disabled with end stage arthritis.The ageing population is predicted to significantl... Total hip replacement(THR) is a successful and reliable operation for both relieving pain and improving function in patients who are disabled with end stage arthritis.The ageing population is predicted to significantly increase the requirement for THR in patients who have a higher functional demand than those of the past. Uncemented THR was introduced to improve the long term results and in particular the results in younger, higher functioning patients. There has been controversy about the value of uncemented compared to cemented THR although there has been a world-wide trend towards uncemented fixation. Uncemented acetabular fixation has gained wide acceptance, as seen in the increasing number of hybrid THR in joint registries, but there remains debate about the best mode of femoral fixation.In this article we review the history and current worldwide registry data, with an in-depth analysis of the New Zealand Joint Registry, to determine the results of uncemented femoral fixation in an attempt to provide an evidence-based answer as to the value of this form of fixation. 展开更多
关键词 PRIMARY total hip replacement FEMORAL fixation CEMENTED UNCEMENTED Joint replacement REGISTRY Implamt survival
下载PDF
Cemented Müller straight stem total hip replacement:18 year survival,clinical and radiological outcomes 被引量:4
10
作者 Vasileios S Nikolaou Demetrios Korres +4 位作者 Stergios Lallos Andreas Mavrogenis Ioannis Lazarettos Ioannis Sourlas Nicolas Efstathopoulos 《World Journal of Orthopedics》 2013年第4期303-308,共6页
AIM: To present the 18 year survival and the clinical and radiological outcomes of the Müller straight stem, cemented, total hip arthroplasty(THA).METHODS: Between 1989 and 2007, 176 primary total hip arthroplast... AIM: To present the 18 year survival and the clinical and radiological outcomes of the Müller straight stem, cemented, total hip arthroplasty(THA).METHODS: Between 1989 and 2007, 176 primary total hip arthroplasties in 164 consecutive patients were performed in our institution by the senior author. All patients received a Müller cemented straight stem and a cemented polyethylene liner. The mean age of the patients was 62 years(45-78). The diagnosis was primary osteoarthritis in 151 hips, dysplasia of the hip in 12 and subcapital fracture of the femur in 13. Following discharge, serial follow-up consisted of clinical evaluation based on the Harris Hip Score and radiological assessment. The survival of the prosthesis using revision for any reason as an end-point was calculated by KaplanMeier analysis.RESULTS: Twenty-four(15%) patients died during the follow-up study, 6(4%) patients were lost, while the remaining 134 patients(141 hips) were followedup for a mean of 10 years(3-18 years). HSS score at the latest follow-up revealed that 84 hips(59.5%) had excellent results, 30(22.2%) good, 11(7.8%) fair and 9(6.3%) poor. There were 3 acetabular revisions due to aseptic loosening. Six(4.2%) stems were diagnosed as having radiographic definitive loosening; however, only 1 was revised. 30% of the surviving stems showed no radiological changes of radiolucency, while 70% showed some changes. Survival of the prosthesis for any reason was 96% at 10 years and 81% at 18 years. CONCLUSION: The 18 year survival of the Müller straight stem, cemented THA is comparable to those of other successful cemented systems. 展开更多
关键词 total hip replacement MULLER STRAIGHT STEM CEMENTED SURVIVORShip
下载PDF
The Association between Surgery Laterality in Orthopedists and the Choices of Prostheses in Total Knee and Hip Replacement 被引量:2
11
作者 Jui-Yang Hsieh Ming-Shu Lan +1 位作者 Ying-Hsiu Chang Jyh-Horng Wang 《Open Journal of Orthopedics》 2018年第7期257-266,共10页
Background: Most orthopedists are right-handed. However, osteoarthritis occurs with equal frequency over both sides. Does perfect and effective arthroplasty surgery require ambidextrous motor skills? Objectives: In th... Background: Most orthopedists are right-handed. However, osteoarthritis occurs with equal frequency over both sides. Does perfect and effective arthroplasty surgery require ambidextrous motor skills? Objectives: In this study, we aimed to investigate the clinical features of arthroplasty for hip and knee joints (THR and TKR) on different sides affected by orthopedist laterality. Patients and Methods: All right-handed orthopedists performed 64 right and 52 left primary THR among 100 patients, and 115 right and 118 left primary TKR among 192 patients. Clinical and surgical features were retrospectively reviewed and analyzed. The body mass index (BMI), inner diameter of acetabular cup liners (ACD), diameter of the femoral head (FHD), diameter of the femoral stem (FSD), and the femoral neck length (FNL) were included in THR-receiving patients. The BMI, femoral component (FC) size, tibial plate (TP) size, and thickness of articular surface inserts (ASI) were included in TKR-receiving patients. Results: No significant differences were observed in ACD, FHD and FSD between patients receiving right and left THR groups (p = 0.16, 0.11, and 0.05, respectively). Similarly, there were no significant differences in FC, TP, and ASI between patients receiving right and left TKR groups (p = 0.06, 0.80, and 0.46, respectively). However, FNL in left THR group was significantly longer than that in right THR group (p = 0.01). Conclusion: This study showed that dexterity or proprioception in handedness had no affect on bone resection and thicknesses of the polyethylene in TKR and acetabular reaming and femoral canal rasping in THR. However, it did lead to differences in femoral neck resection. Right-handed orthopedists significantly tend to perform excessive femoral neck cutting or prefer the larger size of FNL when performing left side THR, while no differences occur when performing TKR. 展开更多
关键词 total hip replacement total Knee replacement HANDEDNESS LATERALITY
下载PDF
Physiologic postoperative presepsin kinetics following primary cementless total hip arthroplasty:A prospective observational study
12
作者 Davide Bizzoca Andrea Piazzolla +3 位作者 Lorenzo Moretti Giovanni Vicenti Biagio Moretti Giuseppe Solarino 《World Journal of Orthopedics》 2023年第7期547-553,共7页
BACKGROUND Presepsin is an emerging biomarker in the diagnosis of sepsis.In the field of orthopaedics,it could be useful in diagnosing and managing periprosthetic joint infections.AIM To define the normal postoperativ... BACKGROUND Presepsin is an emerging biomarker in the diagnosis of sepsis.In the field of orthopaedics,it could be useful in diagnosing and managing periprosthetic joint infections.AIM To define the normal postoperative presepsin plasmatic curve,in patients undergoing primary cementless total hip arthroplasty(THA).METHODS Patients undergoing primary cementless THA at our Institute were recruited.Inclusion criteria were:Primary osteoarthritis of the hip;urinary catheter time of permanence<24 h;peripheral venous cannulation time of permanence<24 h;no postoperative homologous blood transfusion administration and hospital stay≤8 d.Exclusion criteria were:The presence of other articular prosthetic replacement or bone fixation devices;chronic inflammatory diseases;chronic kidney diseases;history of recurrent infections or malignant neoplasms;previous surgery in the preceding 12 mo;diabetes mellitus;immunosuppressive drug or corticosteroid assumption.All the patients received the same antibiotic prophylaxis.All the THA were performed by the same surgical and anaesthesia team;total operative time was defined as the time taken from skin incision to completion of skin closure.At enrollment,anthropometric data,smocking status,osteoarthritis stage according to Kellgren and Lawrence,Harris Hip Score,drugs assumption and comorbidities were recorded.All the patients underwent serial blood tests,including complete blood count,presepsin(PS)and C-reactive protein 24 h before arthroplasty and at 24,48,72 and 96 h postoperatively and at 3,6 and 12-mo follow-up.RESULTS A total of 96 patients(51 female;45 male;mean age=65.74±5.58)were recruited.The mean PS values were:137.54 pg/mL at baseline,192.08 pg/mL at 24 h post-op;254.85 pg/mL at 48 h post-op;259 pg/mL at 72 h post-op;248.6 pg/mL at 96-h post-op;140.52 pg/mL at 3-mo follow-up;135.55 pg/mL at 6-mo follow-up and 130.11 pg/mL at 12-mo follow-up.In two patients(2.08%)a soft-tissue infection was observed;in these patients,higher levels(>350 pg/mL)were recorded at 3-mo follow-up.CONCLUSION The dosage of plasmatic PS concentration is highly recommended in patients undergoing THA before surgery to exclude the presence of an unknown infection.The PS plasmatic concentration should be also assessed at 72 h postoperatively,evaluate the maximum postoperative PS value,and at 96 h post-operatively when a decrease of presepsin should be found.The lack of a presepsin decrease at 96 h post-operatively could be a predictive factor of infection. 展开更多
关键词 Presepsin Periprosthetic joint infection total hip arthroplasty total hip replacement hip surgery Postoperative care
下载PDF
Nomogram to predict postoperative complications in elderly with total hip replacement 被引量:1
13
作者 Xiu-Juan Tan Xiao-Xia Gu +2 位作者 Feng-Min Ge Zhi-Yi Li Liang-Qing Zhang 《World Journal of Clinical Cases》 SCIE 2022年第12期3720-3728,共9页
BACKGROUND By analyzing the risk factors of postoperative complications in elderly patients with hip replacement,We aimed to develop a nomogram model based on preoperative and intraoperative variables and verified the... BACKGROUND By analyzing the risk factors of postoperative complications in elderly patients with hip replacement,We aimed to develop a nomogram model based on preoperative and intraoperative variables and verified the sensitivity and specificity for risk stratification of postoperative complications in elderly with total hip replacement patients.AIM To develop a nomogram model for risk stratification of postoperative complications in elderly with total hip replacement patients.METHODS A total of 414 elderly patients who underwent surgical treatment for total hip replacement hospitalized at the Affiliated Hospital of Guangdong Medical University from March 1,2017 to August 31,2019 were included into this study.Univariate and multivariate logistic regression were conducted to identify independent risk factors of postoperative complication in the 414 patients.A nomogram was developed by R software and validated to predict the risk of postoperative complications.RESULTS Multivariate logistic regression analysis revealed that age(OR=1.05,95%CI:1.00-1.09),renal failure(OR=0.90,95%CI:0.83-0.97),Type 2 diabetes(OR=1.05,95%CI:1.00-1.09),albumin(ALB)(OR=0.91,95%CI:0.83-0.99)were independent risk factors of postoperative complication in elderly patients with hip replacement(P<0.05).For validation of the nomogram,receive operating characteristic curve revealed that the model predicting postoperative complication in elderly patients with hipreplacement was the area under the curve of 0.8254 (95%CI: 0.78-0.87), the slope of the calibrationplot was close to 1 and the model passed Hosmer-Lemeshow goodness of fit test (χ^(2) = 10.16, P =0.4264), calibration in R E_(max) = 0.176, E_(avg) = 0.027, which all demonstrated that the model was ofgood accuracy.CONCLUSIONThe nomogram predicting postoperative complications in patients with total hip replacementconstructed based on age, type 2 diabetes, renal failure and ALB is of good discrimination andaccuracy, which was of clinical significance. 展开更多
关键词 ELDERLY total hip replacement Postoperative complication NOMOGRAM
下载PDF
Total hip replacement using MINIMA^(■)short stem:A short-term follow-up study 被引量:1
14
作者 Georgios I Drosos Stylianos Tottas +3 位作者 Ioannis Kougioumtzis Konstantinos Tilkeridis Christos Chatzipapas Athanasios Ververidis 《World Journal of Orthopedics》 2020年第4期232-242,共11页
BACKGROUND Total hip replacement has become one of the most successful orthopaedic procedures.The length of the femoral stem constitutes one of the most important geometrical and mechanical features of the prosthesis.... BACKGROUND Total hip replacement has become one of the most successful orthopaedic procedures.The length of the femoral stem constitutes one of the most important geometrical and mechanical features of the prosthesis.Several different implants are currently available but data are limited concerning the clinical results for some of these implants.AIM To report the short-term clinical and radiological results of a novel squared section,tapered design–with four conicity-short stem in total hip replacement.METHODS This is a retrospective study of a prospectively collected data using of MINIMA?short stem in 61 consecutive patients with at least 1 year follow-up.The collected data included patients’demographics,type of arthritis,bone morphology,perioperative data,clinical results using Harris Hip Score,EuroQol(EQ-5D),pain score and satisfaction rate,complications and radiological results.RESULTS Total 61 patients were included in our study with a mean age of 56 years of age(range 25-73 years).The majority of them(68.6%)were women,thirty seven patients(56.9%)were less than 60 years of age and almost half of patients(45.1%)suffered from secondary osteoarthritis(hip dysplasia,osteonecrosis,etc.).The mean time of follow-up examination was 33.4 mo(2.8 years)with a range of 12-57 months(1-4.8 years).In 35 patients(56.9%)the follow-up examination was more than 3 years.No major complications such as revision,periprosthetic fracture,dislocation or infection were presented.Re-admission 90 d postoperatively or laterwas deemed unnecessary for any reason regarding the operation.Respectively,the mean pain score,mean Harris hip score,and mean EQ-5D were improved from 6.3,58.7 and 77.3 preoperatively to 0.1,95.1,and 79.8 postoperatively.The Satisfaction rate at the final follow-up was 9.9(SD 0.3,range 8.0-10.0).All stems were classified as stable bone ingrowth and no radiolucent lineswere revealed in any of the modified Gruens’zone at the postoperative Xrays.Stem subsidence was within acceptable limits and the incidence of distal cortical hypertrophy was relatively low.CONCLUSION The clinical and radiological results concerning the MINIMA?short stem are excellent according to this first report of this specific design of the short femoral stems.Because of the small number of cases and short-term follow-up of this study,a longer follow up time and more patients’enrollment is required. 展开更多
关键词 total hip replacement total hip arthroplasty Short-stem hip prostheses Femoral components MINIMA^(■) stem
下载PDF
Leg-length equalization for total hip joint replacement patients 被引量:1
15
作者 马保安 范清宇 +3 位作者 周勇 张勇 杨彤涛 陈军 《中国临床康复》 CSCD 2002年第16期2492-2493,共2页
Objective To investigate the methods to maintain leg equalization for patients undergoing primary total hip joint replacement. Methods 40 patients,45 hips with various diseases were treated by total hip joint replacem... Objective To investigate the methods to maintain leg equalization for patients undergoing primary total hip joint replacement. Methods 40 patients,45 hips with various diseases were treated by total hip joint replacement from Jan 2000 to Sep 2001.Before operation, the perpendicular length from center of femoral head to the summit of great tuberosity and the tip of less tuberosity to the line of bilateral ischial tuberosity were measured; the length from anterior superior iliac spine to medial malleolus were measured at same time.Leg length was decided and corrected according to these lines. Results Before operation, shortening of limbs were presented in 39 hips, 1 to 4 cm, average 2.4 cm.After operation, discrepancy of both legs was 0~0.8 cm.Apparent limps were not observed in all patients. Conclusion This measurement is a useful method to maintain and recover leg length in total hip joint replacement. 展开更多
关键词 人工全髋关节置换术 肢体长度平衡 手术方法
下载PDF
Roles of combined femoral and acetabular anteversion in pathological changes of hip dysplasia and hip reconstructive surgery
16
作者 Can Liu Zheng Xu +5 位作者 Jian-Fa Zeng Zhen-Qi Song Yu-Yin Xie Zhong-Wen Tang Jie Wen Sheng Xiao 《World Journal of Orthopedics》 2024年第5期390-399,共10页
Combined femoral and acetabular anteversion is the sum of femoral and acetabular anteversion,representing their morphological relationship in the axial plane.Along with the increasing understanding of hip dysplasia in... Combined femoral and acetabular anteversion is the sum of femoral and acetabular anteversion,representing their morphological relationship in the axial plane.Along with the increasing understanding of hip dysplasia in recent years,numerous scholars have confirmed the role of combined femoral and acetabular anteversion in the pathological changes of hip dysplasia.At present,the reconstructive surgery for hip dysplasia includes total hip replacement and redirectional hip preservation surgery.As an important surgery index,combined femoral and acetabular anteversion have a crucial role in these surgeries.Herein,we discuss the role of combined femoral and acetabular anteversion in pathological changes of hip dysplasia,total hip replacement,and redirectional hip preservation surgery. 展开更多
关键词 Combined anteversion Femoral anteversion Acetabular anteversion hip dysplasia hip preservation surgery total hip replacement
下载PDF
Comparison of femoral neck fracture healing and affected limb pain after anterolateral-approach minimally invasive total hip replacement and hemiarthroplasty 被引量:1
17
作者 Xiao-Dong Cao Jun Ye Feng-Wu Wang 《Journal of Hainan Medical University》 2017年第4期98-100,共3页
Objective:To study the differences in femoral neck fracture healing and affected limb pain after anterolateral-approach minimally invasive total hip replacement and hemiarthroplasty. Methods:A total of 92 patients wit... Objective:To study the differences in femoral neck fracture healing and affected limb pain after anterolateral-approach minimally invasive total hip replacement and hemiarthroplasty. Methods:A total of 92 patients with femoral neck fracture who received hip replacement in our hospital between May 2013 and December 2015 were selected and randomly divided into total hip and half hip group, total hip group received anterolateral-approach minimally invasive total hip replacement, half hip group received anterolateral-approach minimally invasive hemiarthroplasty, and 1 month after operation, serum was collected to detect the levels of bone metabolism markers, osteocyte cytokines, SP and CGRP.Results:1 month after operation, serum PINP, PICP, BMP, TGF-β, FGF, IGF-I and IGF-II levels of total hip group were significantly higher than those of half hip group while TRAP5b and CatK levels were significantly lower than those of half hip group;the day after operation, serum pain media SP and CGRP levels were not significantly different between the two groups of patients;36 h after operation, serum SP and CGRP levels of total hip group were significantly lower than those of half hip group.Conclusion:The bone metabolism after anterolateral-approach minimally invasive total hip replacement is better than that after hemiarthroplasty, and the degree of pain is less than that after hemiarthroplasty. 展开更多
关键词 FEMORAL NECK fracture total hip replacement Bone metabolism Pain medium
下载PDF
Is overweight or obesity a perioperative risk factor in total hip replacement?
18
作者 Mushtaq AlAssaf Michael Kolbeck +1 位作者 Wolfgang Honle Alexander Schuh 《Health》 2010年第2期157-161,共5页
Introduction: A large proportion of patients who undergo total hip replacement (THR) are obese. Aim of the present study is to investigate the influence of Body Mass Index (BMI) on compli-cations following THR in a si... Introduction: A large proportion of patients who undergo total hip replacement (THR) are obese. Aim of the present study is to investigate the influence of Body Mass Index (BMI) on compli-cations following THR in a single surgeon in the short term follow-up. Material and method: This study was based on the retrospective review of charts and BMIs from 171 patients who had undergone THR between April 2005 and March 2006 at our hospital. All operations were per-formed by a single surgeon. All patients were followed up 6 weeks after operation. Results: 27 / 171 patients (15.8%) were found to have com-plications. Systemic minor complications in-cluded arrythmia in 1 case, urinary tract infec-tion in two cases, ileus in two cases, renal in-sufficiency in 3 cases, confusion in 2 cases and anaemia in 14 cases (8.2%) requiring blood tr- ansfusion. There was one case of pulmonary embolism as a major systemic complication. Local minor complications included one single dislocation and 1 superficial wound infection. Body mass index ranged from 20.8 to 46.7 with a mean of 28.6. Hospital length of stay ranged from 10 to 42 days with a mean of 13. The leng- th of operation time between obese and non- obese patients varied significantly in our study. There was no increased risk for complications and length of hospital stay. Discussion: We can conclude that there are no economic or medical reasons for excluding obese patients from THR as there is no increased risk for complications and length of hospital stay. 展开更多
关键词 total hip replacement COMPLICATION OBESITY BMI BLEEDING
下载PDF
Patients’ Perspectives on Pre-Operative Education for Total Hip Replacement
19
作者 Yi-Li Ko Wei-En Chu Pi-Chu Lin 《Open Journal of Nursing》 2015年第11期987-993,共7页
The purpose of this qualitative research was to explore subjective experiences related to pre-operative patient education experience with total hip replacement (THR). Semi-structured, in depth interviews were used to ... The purpose of this qualitative research was to explore subjective experiences related to pre-operative patient education experience with total hip replacement (THR). Semi-structured, in depth interviews were used to collect data. Eleven participants aged 44 to 76 were recruited. Data were analyzed using a constant comparative method. Three categories emerged from interview data. 1) Obedience professions’ knowledge: trust professions’ authority, synchronization with instruction and satisfy information;2) Worries restrict mobility and lose job: post-op activities changes and impact on daily work;3) Information wanted by personal preference: motivation differently. Hopefully insights on pre-operative education to THR patients experience will provide valuable references for application in teaching materials for orthotics’ nurse to improve THR care. 展开更多
关键词 total hip replacement PATIENT EDUCATION Qualitative Study
下载PDF
Preliminary Report on Phenom<sup>®</sup>Femoral Component in Total Hip Replacement: The Correlation between Outcome Scores in a Cross-Seccional Study
20
作者 Elmano de Araújo Loures Jose Ricardo Barroso Vitoi +3 位作者 Daniel Naya Loures Victor Henrique Coelho Adriano Fernando Mendes Junior Valeria Romero 《Open Journal of Orthopedics》 2021年第4期110-125,共16页
<strong>Background:</strong> The main purpose of the present study was to assess the short term performance of a cementless femoral stem in total hip replacement. <strong>Methods:</strong> Cros... <strong>Background:</strong> The main purpose of the present study was to assess the short term performance of a cementless femoral stem in total hip replacement. <strong>Methods:</strong> Cross-sectional observational study of a 48-patient cohort with Phenom? femoral stems implanted between June 1, 2014 and September 1, 2018, to determine clinical performance, stability, and radiographic osseointegration. Patients were followed-up from 13 to 76 months (mean: 44.5 months) and assessed using the Harris Hip Score-HHS, the Hip Disability and Osteoarthritis Outcome Score-HOOS and radiographs. <strong>Results:</strong> All stems were radiologically stable. Mean Harris Hip Score was 89.8 and the HOOS was 80.4. No statistical differences were observed among patients with different diagnoses. <strong>Conclusions:</strong> The short-term results revealed satisfactory clinical outcomes and radiological signs of implant stability in all cases. Using two functional scores was useful in detecting biases and a low to moderate agreement was found between the scores. 展开更多
关键词 OSSEOINTEGRATION total hip replacement hip Prosthesis Patient-Reported Outcome Scales Functional Scores
下载PDF
上一页 1 2 98 下一页 到第
使用帮助 返回顶部