Objective:To evaluate and analyze the application effect of tracheal stent placement in nutritional support therapy for tracheoesophageal fistula.Methods:Clinical data of 32 patients who underwent nutritional support ...Objective:To evaluate and analyze the application effect of tracheal stent placement in nutritional support therapy for tracheoesophageal fistula.Methods:Clinical data of 32 patients who underwent nutritional support therapy for tracheoesophageal fistula in our hospital from September 2021 to September 2022 were collected,and all patients underwent tracheal silicone stenting,comparing dyspnea classification and Karnofsky score before and after stenting,and conducting post-treatment follow-up.Results:In 32 patients with tracheoesophageal fistula,dyspnea grading improved from grades III and IV to grades 0 to II.Before treatment,10 patients(31.06%)were in grade IV,17 patients(53.12%)were in grade III,and five patients(15.62)were in grade II;after treatment,13 patients(40.63%)were in grade I,12 patients(37.50%)were in grade I,and seven patients(21.87%)were in grade 0(P<0.05);Karnofsky score(37.52±4.86 before treatment)improved significantly to 71.39±8.24 one week after treatment(P<0.05).Nine patients with tracheoesophageal fistula were placed with silicone Y14-10-10 stent,11 with silicone 18-14-14 stent,three with silicone Y15-12-12,and seven with silicone stent 16-13-13.Conclusion:Silicone tracheobronchial stent placement for the treatment of tracheoesophageal fistula is technically feasible,simple,and safe,with reliable near-term efficacy,and is worthy of popularization and application.展开更多
BACKGROUND The protective effect of tracheal stents is reported to relieve airway obstruction and reduce side effects of rapid progression of malignant tracheoesophageal fistula(MTEF)after immunotherapy in this case w...BACKGROUND The protective effect of tracheal stents is reported to relieve airway obstruction and reduce side effects of rapid progression of malignant tracheoesophageal fistula(MTEF)after immunotherapy in this case with 10 mo follow-up.CASE SUMMARY Two kinds of silicone stents were placed in the main airway of a 58-year-old male to relieve the airway obstruction caused by advanced esophageal carcinoma.The patient then received four doses of toripalimab.Subsequently,rapid,progressive deterioration of the original fistula was found.Although the fistula enlarged rapidly after immunotherapy,it remained covered completely,and likely because of this,his condition remained stable.Therefore,immunotherapy could be continued to treat the primary tumor.Despite these efforts,the patient died of the advancement of his esophageal cancer.CONCLUSION Appropriately-sized tracheal stent placement combined with immune checkpoint inhibitors may improve the quality of life and survival of patients with MTEF.展开更多
The paper designed a bionic woven tracheal stent and the stent was a multi-layer tubular structure with a transverse pipeline.Polydioxanone( PDO) monofilament and β-hydroxybutyrate and β-hydroxyvalerate copolymers/p...The paper designed a bionic woven tracheal stent and the stent was a multi-layer tubular structure with a transverse pipeline.Polydioxanone( PDO) monofilament and β-hydroxybutyrate and β-hydroxyvalerate copolymers/polylactic( PHBV/PLA) multifilament were chosen as the tissue engineering tracheal stent materials,and chitosan was chosen as the coating material. This study selected appropriate basic fabric structures and prepared the tracheal stent by setting reasonable weaving parameters,then treated the sample with coating and heat setting. Radical compression performances of the horizontal pipeline and longitudinal pipeline of this tracheal stent were investigated,and the experimental results showed that the stent had good performance on radial supporting force and elastic recovery,which meant it could supply adequate supports for cell growth and tissue regeneration of tracheal lesions; the horizontal pipeline could provide a good experimental foundation for reconstruction of the cartilage ring.展开更多
In this paper, the development of existing artificial tracheal stents was briefly introduced. Their structures, strengths and weaknesses were analyzed. A new woven artificial tracheal stent that used leno-based constr...In this paper, the development of existing artificial tracheal stents was briefly introduced. Their structures, strengths and weaknesses were analyzed. A new woven artificial tracheal stent that used leno-based construction was designed and fabricated at last. Additionally, a preliminary mechanical study was carried out on the new artificial tracheal stent, such as the radial supporting force and the elastic restoring force, making foundation for application of the new artificial tracheal stent.展开更多
Background: The correlation between computed tomography (CT)-based tracheal size and spirometry values is unknown in patients with tracheal stenosis by thoracic malignancy, which is often treated by tracheal stenting....Background: The correlation between computed tomography (CT)-based tracheal size and spirometry values is unknown in patients with tracheal stenosis by thoracic malignancy, which is often treated by tracheal stenting. Objectives: To evaluate the correlation between the tracheal cross-sectional area (CSA) and spirometric values before and after tracheal stenting, and to confirm that greater improvement in tracheal CSA leads to a larger improvement in spirometry values. Methods: A total of 32 patients with malignant tracheal stenosis underwent tracheal stenting. Before (n = 32) and after (n = 27) treatment, patients underwent chest CT, measuring mean and minimum tracheal CSA values, and spirometry. The correlation between tracheal CSA and each spirometric value was evaluated using Spearman rank correlation analysis. Differences in the pre- and posttreatment tracheal CSA and spirometric values were evaluated using the Wilcoxon matched-pairs test. Results: Significant improvement in the minimum tracheal CSA and in spirometric values was observed after stenting (P P P Conclusions: The tracheal size measured on chest CT correlates with patients’ spirometric values, particularly at the prestenting examination, in patients with malignant tracheal stenosis. The increase in the minimum tracheal CSA after stenting on CT is a predictor for improved spirometric values, which is first demonstrated by this study.展开更多
Background In-stent restenosis caused by airway granulation poses a challenge due to the high incidence of recurrence after treatment.Weekly applications of anti-proliferative drugs have potential value in delaying th...Background In-stent restenosis caused by airway granulation poses a challenge due to the high incidence of recurrence after treatment.Weekly applications of anti-proliferative drugs have potential value in delaying the recurrence of airway obstruction.However,it is not practical to subject patients to repeated bronchoscopy and topical drug applications.We fabricated novel pacilitaxel-eluting tracheal stents with sustained and slow pacilitaxel release,which could inhibit the formation of granulation tissue.And we assessed the quality and drug release behaviors of drug-eluting stents (DESs) in vitro.Methods Stents were dipped vertically into a coating solution prepared by dissolving 0.5 g (2% w/v) of poly lactic acid-coglycolic acid (PLGA) and 0.025 g (0.1% w/v) of pacilitaxel in 25 ml of dichloromethane.DES morphology was examined by scanning electron microscopy (SEM).Pacilitaxel release kinetics from these DESs was investigated in vitro by shaking in PBS buffer followed by high performance liquid chromatography (HPLC).Results Using an orthogonal experimental design,we fabricated numerous pacilitaxel/PLGA eluting tracheal stents to assess optimum coating proportions.The optimum coating proportion was 0.1% (w/v) pacilitaxel and 2% (w/v) PLGA,which resulted in total pacilitaxel loading of (16.380 6±0.002 1) mg/stent.By SEM the coating was very smooth and uniform.Pacilitaxel released from DES was at (0.376 3±0.003 8) mg/d,which is a therapeutic level.There was a prolonged,sustained release of pacilitaxel of >40 days.Conclusions Paclitaxel-loaded PLGA coating tracheal stents were successfully developed and evaluated.Quality assessments demonstrated favorable surface morphology as well as sustained and effective drug release behavior,which provides an experimental reference for clinical practitioners.展开更多
has a good application prospect.The biodegradable stent can effectively reduce the damage to patients and improve the therapeutic performance of stents.In this work,a series of shape memory polylactic acid(Fe_(3)O_(4)...has a good application prospect.The biodegradable stent can effectively reduce the damage to patients and improve the therapeutic performance of stents.In this work,a series of shape memory polylactic acid(Fe_(3)O_(4))composite tracheal stents were manufactured by 4D printing.The composite tracheal stents with different structures were designed.Moreover,with the addition of magnetic particles Fe3 O4,the shape memory PLA/Fe_(3)O_(4)composite tracheal stent has a magnetic driving effect.Under the magnetic field,the shape recovery process is completed within 40 s,and the shape recovery rate is more than 99%.Moreover,the 4D printed tracheal stent was also triggered by the irradiation of infrared lamp to realize the remote controlling recovery.The research on the structure design and driving method of 4D printing tracheal stent expands the application scope of shape memory polymer composites in biomedical field,provides a new way for personalized implantable medical devices and minimally invasive surgery.It is of great significance for better precision medical treatment.展开更多
Background:Currently available silicone and metallic stents for tracheal stenosis are associated with many problems.Granulation proliferation is one of the main complications.The present study aimed to evaluate the e...Background:Currently available silicone and metallic stents for tracheal stenosis are associated with many problems.Granulation proliferation is one of the main complications.The present study aimed to evaluate the efficacy of paclitaxel drug-eluting tracheal stent in reducing granulation tissue formation in a canine model,as well as the pharmacokinetic features and safety profiles of the coated drug.Methods:Eight beagles were randomly divided into a control group (bare-metal stent group,n =4) and an experimental group (paclitaxel-eluting stent group,n =4).The observation period was 5 months.One beagle in both groups was sacrificed at the end of the 1st and 3rd months,respectively.The last two beagles in both groups were sacrificed at the end of 5th month.The proliferation of granulation tissue and changes in tracheal mucosa were compared between the two groups.Blood routine and liver and kidney function were monitored to evaluate the safety of the paclitaxel-eluting stent.The elution method and high-performance liquid chromatography were used to characterize the rate of in vivo release of paclitaxel from the stent.Results:Compared with the control group,the proliferation of granulation tissue in the experimental group was significantly reduced.The drug release of paclitaxel-eluting stent was the fastest in the 1st month after implantation (up to 70.9%).Then,the release slowed down gradually.By the 54 month,the release reached up to 98.5%.During the observation period,a high concentration of the drug in the trachea (in the stented and adjacent unstented areas) and lung tissue was not noted,and the blood test showed no side effect.Conclusions:The paclitaxel-eluting stent could safely reduce the granulation tissue formation after stent implantation in vivo,suggesting that the paclitaxel-eluting tracheal stent might be considered for potential use in humans in the future.展开更多
A 38 year-old man was admitted because of half a year of recurrent bouts of eough and shortness of breath and 20 days of hemoptysis. He had been apparently healthy until the illness. In the recent 6 months, the dyspne...A 38 year-old man was admitted because of half a year of recurrent bouts of eough and shortness of breath and 20 days of hemoptysis. He had been apparently healthy until the illness. In the recent 6 months, the dyspnea and fatigue gradually onset and became more severe, the hemoptysis being 100-200 mL per day. Spells of chest pain are associated with coughing. Despite accepting antibiotic and antispasmodic therapy in a hospital, there was no obvious improvement and he was transferred to our hospital. Physical examination on admission: He was in acute distress and anemic face With P 110/min., R 30/min., T36. 8oC and Bp 100/60 mmHg. There were Wheezes, medium and fine展开更多
Tracheal stents are an important form of treatment for benign or malignant central airway obstruction.However,the mechanical behavior of current tracheal stents is significantly different from that of the native trach...Tracheal stents are an important form of treatment for benign or malignant central airway obstruction.However,the mechanical behavior of current tracheal stents is significantly different from that of the native trachea,which leads to a variety of serious complications.In this study,inspired by the structure of the native trachea,a wavy non-uniform ligament chiral tracheal stent is proposed,in which J-shaped stress-strain behavior and negative Poisson's ratio response are achieved by replacing the tangential ligament of tetrachiral and anti-tetrachiral hybrid structure with a wavy non-uniform ligament.Through the combination of theoretical analysis,finite element analysis and experimental tests,a wide range of desired J-shaped stress-strain curves are explored to mimic the native porcine trachea by tailoring the stent geometry.Besides,the negative Poisson’s ratio and auxetic diameter curves versus axial strain of the stent are also studied in detail,thus contributing to the enhancement of cross-section ventilation and reducing the migration of the stent.This novel tracheal stent with a unique microstructure shows a potential to perfectly match the physiological activities of the native trachea and thereby reduce potential complications.展开更多
Esophageo-tracheal fistula is a rare condition,and in most cases such fistulas are caused by malignant disease or emergency endotracheal intubation.A case where a wrapped tablet produced a fistula between the esophagu...Esophageo-tracheal fistula is a rare condition,and in most cases such fistulas are caused by malignant disease or emergency endotracheal intubation.A case where a wrapped tablet produced a fistula between the esophagus and trachea is described.The patient is a male born in 1938 who swallowed a tablet without unwrapping it.The patient was treated with selfexpanding metal stents(SEMS),but closure of the fistula was not achieved.Different examinations and treatment options are discussed.Surgical treatment for this condition has demonstrated considerable mortality and morbidity.In some cases closure of the fistula can be achieved by use of SEMS.Although we advise treatment of such cases with SEMS,in some cases treatment with stents will prove troublesome and the risk/benefit analysis will have to be reevaluated.展开更多
Narrowing of the airway caused by different diseases is a serious condition manifesting varying signs and symptoms. Immediate attention and treatment must be performed as this is a life-threatening condition. In the p...Narrowing of the airway caused by different diseases is a serious condition manifesting varying signs and symptoms. Immediate attention and treatment must be performed as this is a life-threatening condition. In the past decade, there has been massive advancement on the management of airway stenosis. Some of these are stent placement, tracheal reconstruction and tumor debulking. This article focuses on 5 different cases with distinct strategies in conducting treatment and management of airway stenosis.展开更多
文摘Objective:To evaluate and analyze the application effect of tracheal stent placement in nutritional support therapy for tracheoesophageal fistula.Methods:Clinical data of 32 patients who underwent nutritional support therapy for tracheoesophageal fistula in our hospital from September 2021 to September 2022 were collected,and all patients underwent tracheal silicone stenting,comparing dyspnea classification and Karnofsky score before and after stenting,and conducting post-treatment follow-up.Results:In 32 patients with tracheoesophageal fistula,dyspnea grading improved from grades III and IV to grades 0 to II.Before treatment,10 patients(31.06%)were in grade IV,17 patients(53.12%)were in grade III,and five patients(15.62)were in grade II;after treatment,13 patients(40.63%)were in grade I,12 patients(37.50%)were in grade I,and seven patients(21.87%)were in grade 0(P<0.05);Karnofsky score(37.52±4.86 before treatment)improved significantly to 71.39±8.24 one week after treatment(P<0.05).Nine patients with tracheoesophageal fistula were placed with silicone Y14-10-10 stent,11 with silicone 18-14-14 stent,three with silicone Y15-12-12,and seven with silicone stent 16-13-13.Conclusion:Silicone tracheobronchial stent placement for the treatment of tracheoesophageal fistula is technically feasible,simple,and safe,with reliable near-term efficacy,and is worthy of popularization and application.
基金Supported by National Natural Science Foundation of China,No. 81973784
文摘BACKGROUND The protective effect of tracheal stents is reported to relieve airway obstruction and reduce side effects of rapid progression of malignant tracheoesophageal fistula(MTEF)after immunotherapy in this case with 10 mo follow-up.CASE SUMMARY Two kinds of silicone stents were placed in the main airway of a 58-year-old male to relieve the airway obstruction caused by advanced esophageal carcinoma.The patient then received four doses of toripalimab.Subsequently,rapid,progressive deterioration of the original fistula was found.Although the fistula enlarged rapidly after immunotherapy,it remained covered completely,and likely because of this,his condition remained stable.Therefore,immunotherapy could be continued to treat the primary tumor.Despite these efforts,the patient died of the advancement of his esophageal cancer.CONCLUSION Appropriately-sized tracheal stent placement combined with immune checkpoint inhibitors may improve the quality of life and survival of patients with MTEF.
基金Biomedical Textile Materials Science and Technology(111 Project),China(No.B07024)National Natural Science Foundation of China(No.H0106)Shanghai Pujiang Program,China(No.2015PJC0002)
文摘The paper designed a bionic woven tracheal stent and the stent was a multi-layer tubular structure with a transverse pipeline.Polydioxanone( PDO) monofilament and β-hydroxybutyrate and β-hydroxyvalerate copolymers/polylactic( PHBV/PLA) multifilament were chosen as the tissue engineering tracheal stent materials,and chitosan was chosen as the coating material. This study selected appropriate basic fabric structures and prepared the tracheal stent by setting reasonable weaving parameters,then treated the sample with coating and heat setting. Radical compression performances of the horizontal pipeline and longitudinal pipeline of this tracheal stent were investigated,and the experimental results showed that the stent had good performance on radial supporting force and elastic recovery,which meant it could supply adequate supports for cell growth and tissue regeneration of tracheal lesions; the horizontal pipeline could provide a good experimental foundation for reconstruction of the cartilage ring.
基金Shanghai Municipal Commission of Health and Family Planning,China
文摘In this paper, the development of existing artificial tracheal stents was briefly introduced. Their structures, strengths and weaknesses were analyzed. A new woven artificial tracheal stent that used leno-based construction was designed and fabricated at last. Additionally, a preliminary mechanical study was carried out on the new artificial tracheal stent, such as the radial supporting force and the elastic restoring force, making foundation for application of the new artificial tracheal stent.
文摘Background: The correlation between computed tomography (CT)-based tracheal size and spirometry values is unknown in patients with tracheal stenosis by thoracic malignancy, which is often treated by tracheal stenting. Objectives: To evaluate the correlation between the tracheal cross-sectional area (CSA) and spirometric values before and after tracheal stenting, and to confirm that greater improvement in tracheal CSA leads to a larger improvement in spirometry values. Methods: A total of 32 patients with malignant tracheal stenosis underwent tracheal stenting. Before (n = 32) and after (n = 27) treatment, patients underwent chest CT, measuring mean and minimum tracheal CSA values, and spirometry. The correlation between tracheal CSA and each spirometric value was evaluated using Spearman rank correlation analysis. Differences in the pre- and posttreatment tracheal CSA and spirometric values were evaluated using the Wilcoxon matched-pairs test. Results: Significant improvement in the minimum tracheal CSA and in spirometric values was observed after stenting (P P P Conclusions: The tracheal size measured on chest CT correlates with patients’ spirometric values, particularly at the prestenting examination, in patients with malignant tracheal stenosis. The increase in the minimum tracheal CSA after stenting on CT is a predictor for improved spirometric values, which is first demonstrated by this study.
文摘Background In-stent restenosis caused by airway granulation poses a challenge due to the high incidence of recurrence after treatment.Weekly applications of anti-proliferative drugs have potential value in delaying the recurrence of airway obstruction.However,it is not practical to subject patients to repeated bronchoscopy and topical drug applications.We fabricated novel pacilitaxel-eluting tracheal stents with sustained and slow pacilitaxel release,which could inhibit the formation of granulation tissue.And we assessed the quality and drug release behaviors of drug-eluting stents (DESs) in vitro.Methods Stents were dipped vertically into a coating solution prepared by dissolving 0.5 g (2% w/v) of poly lactic acid-coglycolic acid (PLGA) and 0.025 g (0.1% w/v) of pacilitaxel in 25 ml of dichloromethane.DES morphology was examined by scanning electron microscopy (SEM).Pacilitaxel release kinetics from these DESs was investigated in vitro by shaking in PBS buffer followed by high performance liquid chromatography (HPLC).Results Using an orthogonal experimental design,we fabricated numerous pacilitaxel/PLGA eluting tracheal stents to assess optimum coating proportions.The optimum coating proportion was 0.1% (w/v) pacilitaxel and 2% (w/v) PLGA,which resulted in total pacilitaxel loading of (16.380 6±0.002 1) mg/stent.By SEM the coating was very smooth and uniform.Pacilitaxel released from DES was at (0.376 3±0.003 8) mg/d,which is a therapeutic level.There was a prolonged,sustained release of pacilitaxel of >40 days.Conclusions Paclitaxel-loaded PLGA coating tracheal stents were successfully developed and evaluated.Quality assessments demonstrated favorable surface morphology as well as sustained and effective drug release behavior,which provides an experimental reference for clinical practitioners.
基金This work is funded by the National Natural Science Foundation of China[Grant No.11802075,11632005]This work was also funded by the China Postdoctoral Science Foundation。
文摘has a good application prospect.The biodegradable stent can effectively reduce the damage to patients and improve the therapeutic performance of stents.In this work,a series of shape memory polylactic acid(Fe_(3)O_(4))composite tracheal stents were manufactured by 4D printing.The composite tracheal stents with different structures were designed.Moreover,with the addition of magnetic particles Fe3 O4,the shape memory PLA/Fe_(3)O_(4)composite tracheal stent has a magnetic driving effect.Under the magnetic field,the shape recovery process is completed within 40 s,and the shape recovery rate is more than 99%.Moreover,the 4D printed tracheal stent was also triggered by the irradiation of infrared lamp to realize the remote controlling recovery.The research on the structure design and driving method of 4D printing tracheal stent expands the application scope of shape memory polymer composites in biomedical field,provides a new way for personalized implantable medical devices and minimally invasive surgery.It is of great significance for better precision medical treatment.
文摘Background:Currently available silicone and metallic stents for tracheal stenosis are associated with many problems.Granulation proliferation is one of the main complications.The present study aimed to evaluate the efficacy of paclitaxel drug-eluting tracheal stent in reducing granulation tissue formation in a canine model,as well as the pharmacokinetic features and safety profiles of the coated drug.Methods:Eight beagles were randomly divided into a control group (bare-metal stent group,n =4) and an experimental group (paclitaxel-eluting stent group,n =4).The observation period was 5 months.One beagle in both groups was sacrificed at the end of the 1st and 3rd months,respectively.The last two beagles in both groups were sacrificed at the end of 5th month.The proliferation of granulation tissue and changes in tracheal mucosa were compared between the two groups.Blood routine and liver and kidney function were monitored to evaluate the safety of the paclitaxel-eluting stent.The elution method and high-performance liquid chromatography were used to characterize the rate of in vivo release of paclitaxel from the stent.Results:Compared with the control group,the proliferation of granulation tissue in the experimental group was significantly reduced.The drug release of paclitaxel-eluting stent was the fastest in the 1st month after implantation (up to 70.9%).Then,the release slowed down gradually.By the 54 month,the release reached up to 98.5%.During the observation period,a high concentration of the drug in the trachea (in the stented and adjacent unstented areas) and lung tissue was not noted,and the blood test showed no side effect.Conclusions:The paclitaxel-eluting stent could safely reduce the granulation tissue formation after stent implantation in vivo,suggesting that the paclitaxel-eluting tracheal stent might be considered for potential use in humans in the future.
文摘A 38 year-old man was admitted because of half a year of recurrent bouts of eough and shortness of breath and 20 days of hemoptysis. He had been apparently healthy until the illness. In the recent 6 months, the dyspnea and fatigue gradually onset and became more severe, the hemoptysis being 100-200 mL per day. Spells of chest pain are associated with coughing. Despite accepting antibiotic and antispasmodic therapy in a hospital, there was no obvious improvement and he was transferred to our hospital. Physical examination on admission: He was in acute distress and anemic face With P 110/min., R 30/min., T36. 8oC and Bp 100/60 mmHg. There were Wheezes, medium and fine
基金supported by the National Key Research and Development Program of China(No.2020YFC1107103)the National Natural Science Foundation of China(No.51821093)the Research Project of Public Welfare Technology Application of Zhejiang Province,China(No.LGF21H010006).
文摘Tracheal stents are an important form of treatment for benign or malignant central airway obstruction.However,the mechanical behavior of current tracheal stents is significantly different from that of the native trachea,which leads to a variety of serious complications.In this study,inspired by the structure of the native trachea,a wavy non-uniform ligament chiral tracheal stent is proposed,in which J-shaped stress-strain behavior and negative Poisson's ratio response are achieved by replacing the tangential ligament of tetrachiral and anti-tetrachiral hybrid structure with a wavy non-uniform ligament.Through the combination of theoretical analysis,finite element analysis and experimental tests,a wide range of desired J-shaped stress-strain curves are explored to mimic the native porcine trachea by tailoring the stent geometry.Besides,the negative Poisson’s ratio and auxetic diameter curves versus axial strain of the stent are also studied in detail,thus contributing to the enhancement of cross-section ventilation and reducing the migration of the stent.This novel tracheal stent with a unique microstructure shows a potential to perfectly match the physiological activities of the native trachea and thereby reduce potential complications.
文摘Esophageo-tracheal fistula is a rare condition,and in most cases such fistulas are caused by malignant disease or emergency endotracheal intubation.A case where a wrapped tablet produced a fistula between the esophagus and trachea is described.The patient is a male born in 1938 who swallowed a tablet without unwrapping it.The patient was treated with selfexpanding metal stents(SEMS),but closure of the fistula was not achieved.Different examinations and treatment options are discussed.Surgical treatment for this condition has demonstrated considerable mortality and morbidity.In some cases closure of the fistula can be achieved by use of SEMS.Although we advise treatment of such cases with SEMS,in some cases treatment with stents will prove troublesome and the risk/benefit analysis will have to be reevaluated.
文摘Narrowing of the airway caused by different diseases is a serious condition manifesting varying signs and symptoms. Immediate attention and treatment must be performed as this is a life-threatening condition. In the past decade, there has been massive advancement on the management of airway stenosis. Some of these are stent placement, tracheal reconstruction and tumor debulking. This article focuses on 5 different cases with distinct strategies in conducting treatment and management of airway stenosis.