期刊文献+
共找到8,535篇文章
< 1 2 250 >
每页显示 20 50 100
Color Doppler ultrasound imaging in varicoceles: Is the difference in venous diameter encountered during Valsalva predictive of palpable varicocele grade?
1
作者 Kelly Lehner Catherine Ingram +7 位作者 Utsav Bansal Colleen Baca Adithya Balasubramanian Nannan Thirumavalavan Jason M.Scovell Saneal Rajanahally Matthew Pollard Larry I.Lipshultz 《Asian Journal of Urology》 CSCD 2023年第1期27-32,共6页
Objective:The clinical grading system for varicoceles is subjective and dependent on clinician experience.Color Doppler ultrasound(US)has not been standardized in the diagnosis of varicoceles.We aimed to determine if ... Objective:The clinical grading system for varicoceles is subjective and dependent on clinician experience.Color Doppler ultrasound(US)has not been standardized in the diagnosis of varicoceles.We aimed to determine if US measurement of varicocele could be predictive of World Health Organization(WHO)varicocele grade.Methods:Men who presented for either scrotal pain or infertility to a tertiary men’s health clinic underwent physical examination,and varicoceles were graded following WHO criteria(0Zsubclinical,1,2,3).US was used to measure largest venous diameter in the pampiniform plexus bilaterally at rest and during Valsalva maneuver.Receiver operator characteristic curve analysis was used to determine if resting diameter,diameter during Valsalva,or change in diameter between at rest and during Valsalva provided the highest sensitivity and specificity for determining clinical grade.Threshold values for diameter were determined from these receiver operator characteristic curves.Results:A total of 102 men(50 with clinical varicocele and 52 with subclinical varicocele)were included.Diameter at rest was the best ultrasonographic discriminator between subclinical and clinical varicoceles(area under the curve[AUC]Z0.67)with a diameter threshold of 3.0 mm(sensitivity 79%,specificity 42%).Diameter during Valsalva had the greatest AUC for determining clinical Grades 1 versus 2(AUCZ0.57)with diameter threshold of 5.7 mm(sensitivity 71%,specificity 33%).For differentiating between Grades 2 and 3,diameter at rest had the greatest AUC of 0.65 with a threshold of 3.6 mm(sensitivity 71%,specificity 58%).Conclusion:Our results corroborate other studies that have shown a weak correlation between US and clinical grading.The use of diameter during Valsalva was less predictive than diameter at rest and was only clinically significant in differentiating between Grade 1 and 2 varicocele.A standardized method for determining clinically relevant varicoceles on US would allow for improved patient counseling and clinical decision-making. 展开更多
关键词 VARICOCELE ultrasound doppler Venous plexus INFERTILITY
下载PDF
Venous Doppler flow patterns,venous congestion,heart disease and renal dysfunction:A complex liaison 被引量:1
2
作者 Alessio Di Maria Rossella Siligato +1 位作者 Marta Bondanelli Fabio Fabbian 《World Journal of Cardiology》 2024年第1期5-9,共5页
The World Journal of Cardiology published an article written by Kuwahara et al that we take the pleasure to comment on.We focused our attention on venous congestion.In intensive care settings,it is now widely accepted... The World Journal of Cardiology published an article written by Kuwahara et al that we take the pleasure to comment on.We focused our attention on venous congestion.In intensive care settings,it is now widely accepted that venous congestion is an important clinical feature worthy of investigation.Evaluating venous Doppler profile abnormalities at multiple sites could suggest adequate treatment and monitor its efficacy.Renal dysfunction could trigger or worsen fluid overload in heart disease,and cardio-renal syndrome is a well-characterized spectrum of disorders describing the complex interactions between heart and kidney diseases.Fluid overload and venous congestion,including renal venous hypertension,are major determinants of acute and chronic renal dysfunction arising in heart disease.Organ congestion from venous hypertension could be involved in the development of organ injury in several clinical situations,such as critical diseases,congestive heart failure,and chronic kidney disease.Ultrasonography and abnormal Doppler flow patterns diagnose clinically significant systemic venous congestion.Cardiologists and nephrologists might use this valuable,noninvasive,bedside diagnostic tool to establish fluid status and guide clinical choices. 展开更多
关键词 Cardio-renal syndrome Fluid overload Venous congestion Acute kidney injury ultrasound doppler flow patterns
下载PDF
Investigation of lacrimal sac space-occupying lesions using color doppler ultrasound, computed tomography, and computed tomography dacryocystography
3
作者 Zhen-Bin Qian Bo Yu +3 位作者 Ye Yang Wei Fang Jian-Li Dong Li-Qing Wei 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第8期1224-1230,共7页
AIM:To observe the imaging features of color Doppler ultrasound(CDU)and computed tomography(CT)or computed tomography dacryocystography(CT-DCG)in different types of lacrimal sac space-occupying lesions(SOLs).METHODS:T... AIM:To observe the imaging features of color Doppler ultrasound(CDU)and computed tomography(CT)or computed tomography dacryocystography(CT-DCG)in different types of lacrimal sac space-occupying lesions(SOLs).METHODS:This retrospective case series study included 21 patients with lacrimal sac SOLs who underwent lacrimal sac surgery between January 2018 and March 2022.The imaging features of CDU and CT or CT-DCG in these patients were extracted from the examination cloud system.The images were observed and analyzed.RESULTS:The detection rate of lacrimal SOLs between CDU(21/21,100%)and CT or CT-DCG(20/21,95.2%)had no statistically significant difference(P=1.0).CDU could detect the blood flow signals in all SOLs except mucocele and mucopeptide concretion.Among them,polyps had characteristic imaging changes on CDU and CT-DCG.The mucoceles and mucopeptide concretions had characteristic imaging changes on CDU,which could provide more information for differential diagnosis.CONCLUSION:The morphology and internal blood flow signals of lacrimal sac SOLs can be observed using CDU.CT or CT-DCG has advantages in observing structural damage around the lacrimal sac mass.Therefore,CDU may be used as a routine examination to exclude lacrimal sac SOLs before dacryocystorhinostomy in the absence of preoperative CT or CT-DCG. 展开更多
关键词 lacrimal sac computed tomography computed tomography dacryocystography color doppler ultrasound space-occupying lesions
下载PDF
Point-of-care ultrasonography spotlight:Could venous excess ultrasound serve as a shared language for internists and intensivists?
4
作者 Anosh Aslam Khan Hasham Saeed +3 位作者 Ibtehaj Ul Haque Ayman Iqbal Doantrang Du Abhilash Koratala 《World Journal of Critical Care Medicine》 2024年第2期126-136,共11页
Point-of-care ultrasonography(POCUS),particularly venous excess ultrasound(VExUS)is emerging as a valuable bedside tool to gain real-time hemodynamic insights.This modality,derived from hepatic vein,portal vein,and in... Point-of-care ultrasonography(POCUS),particularly venous excess ultrasound(VExUS)is emerging as a valuable bedside tool to gain real-time hemodynamic insights.This modality,derived from hepatic vein,portal vein,and intrarenal vessel Doppler patterns,offers a scoring system for dynamic venous congestion assessment.Such an assessment can be crucial in effective management of patients with heart failure exacerbation.It facilitates diagnosis,quantification of congestion,prognostication,and monitoring the efficacy of decongestive therapy.As such,it can effectively help to manage cardiorenal syndromes in various clinical settings.Extended or eVExUS explores additional veins,potentially broadening its applications.While VExUS demonstrates promising outcomes,challenges persist,particularly in cases involving renal and liver parenchymal disease,arrhythmias,and situations of pressure and volume overload overlap.Proficiency in utilizing spectral Doppler is pivotal for clinicians to effectively employ this tool.Hence,the integration of POCUS,especially advanced applications like VExUS,into routine clinical practice necessitates enhanced training across medical specialties. 展开更多
关键词 Point-of-care ultrasonography ultrasound Venous excess ultrasound doppler Congestion Heart failure
下载PDF
Hemodynamic analysis of esophageal varices in patients with liver cirrhosis using color Doppler ultrasound 被引量:24
5
作者 Feng-Hua Li Jing Hao +2 位作者 Jian-Guo Xia Hong-Li Li Hua Fang 《World Journal of Gastroenterology》 SCIE CAS CSCD 2005年第29期4560-4565,共6页
AIM: To study the portal hemodynamics and their relationship with the size of esophageal varices seen at endoscopy and to evaluate whether these Doppler ultrasound parameters might predict variceal bleeding in patien... AIM: To study the portal hemodynamics and their relationship with the size of esophageal varices seen at endoscopy and to evaluate whether these Doppler ultrasound parameters might predict variceal bleeding in patients with liver cirrhosis and portal hypertension. METHODS: One hundred and twenty cirrhotic patients with esophageal varices but without any previous bleeding were enrolled in the prospective study. During a 2-year observation period, 52 patients who had at least one episode of acute esophageal variceal hemorrhage constituted the bleeding group, and the remaining 68 patients without any previous hemorrhage constituted the non-bleeding group. All patients underwent endoscopy before or after color Doppler-ultrasonic examination, and images were interpreted independently by two endoscopists. The control group consisted of 30 healthy subjects, matched to the patient group in age and gender. Measurements of diameter, flow direction and flow velocity in the left gastric vein (LGV) and the portal vein (PV) were done in all patients and controls using color Doppler unit. After baseline measurements, 30 min after oral administration of 75 g glucose in 225 mL, changes of the diameter, flow velocity and direction in the PV and LGV were examined in 60 patients with esophageal varices and 15 healthy controls. RESULTS: The PV and LGV were detected successfully in 115 (96%) and 105 (88%) of 120 cirrhotic patients, respectively, and in 27 (90%) and 21 (70%) of 30 healthy controls, respectively. Among the 120 cirrhotic patients, 37 had F1, 59 had F2, and 24 had F3 grade varices. Compared with the healthy controls, cirrhotic group had a significantly lower velocity in the PV, a significantly greater diameter of the PV and LGV, and a higher velocity in the LGV. In the cirrhotic group, no difference in portal flow velocity and diameter were observed between patients with or without esophageal variceal bleeding (EVB). However, the diameter and blood flow velocity of the LGV were significantly higher for EVB (+) group compared with EVB (-) group (P〈0.01). Diameter of the LGV increased with enlarged size of varices. There were differences between F1 and F2, F1 and F3 varices, but no differences between F2 and F3 varices (P = 0.125). However, variceal bleeding was more frequent in patients with a diameter of LGV 〉6 mm. The flow velocity in the LGV of healthy controls was 8.70+1.91 cm/s (n = 21). In patients with liver cirrhosis, it was 10.3+2.1 cm/s (n = 12) when the flow was hepatopetal and 13.5+2.3 cm/s (n = 87) when it was hepatofugal. As the size of varices enlarged, hepatofugal flow velocity increased (P〈0.01) and was significantly different between patients with F1 and F2 varices and between patients with F2 and F3 varices. Variceal bleeding was more frequent in patients with a hepatofugal flow velocity 〉15 cm/s (32 of 52 patients, 61.5%). Within the bleeding group, the mean LGV blood flow velocity was 16.6+2.62 cm/s. No correlation was observed between the portal blood flow velocity and EVB. In all healthy controls, the flow direction in the LGV was hepatopetal, toward the PV. In patients with F1 varices, flow direction was hepatopetal in 10 patients, to-and-fro state in 3 patients, and hepatofugal in the remaining 18. The flow was hepatofugal in 91% patients with F2 and all F3 varices. Changes in diameter of the PV and LGV were not significant before and after ingestion of glucose (PV: 1.41+1.5 cm before and 1.46+1.6 cm after; LGV: 0.57+1.7 cm before and 0.60+1.5 cm after). Flow direction in the LGV was hepatopetal and to-and-fro in 16 patients and hepatofugal in 44 patients before ingestion of glucose. Flow direction changed to hepatofugal in 9 of 16 patients with hepatopetal and to-and-fro blood flow after ingestion of glucose. In 44 patients with hepatofugal blood flow in the LGV, a significant increase in hepatofugal flow velocity was observed in 38 of 44 patients (86%) with esophageal varices. There was a relationship between the percentage changes in flow velocity and the size of varices. Patients who responded excessively to food ingestion might have a high risk for bleeding. The changes of blood flow velocity in the LGV were greater than those in the PV (LGV: 28.3+26.1%, PV: 7.2+13.2%, P〈0.01), whereas no significant changes in the LGV occurred before and after ingestion of glucose in the control subjects. CONCLUSION: Hemodynamics of the PV is unrelated to the degree of endoscopic abnormalities in patients with liver cirrhosis. The most important combinations are endoscopic findings followed by the LGV hemodynamics. Duplex-Doppler ultrasonography has no value in the identification of patients with cirrhosis at risk of variceal bleeding. Hemodynamics of the LGV appears to be superior to those of the PV in predicting bleeding. 展开更多
关键词 HEMODYNAMICS Esophageal varices Liver cirrhosis Color doppler ultrasound
下载PDF
FEASIBILITY STUDY OF AN ULTRASOUND CONTRAST AGENT(LEVOVIST) IN COLOR DOPPLER IMAGING OF LIVER NEOPLASMS 被引量:6
6
作者 姜玉新 戴晴 +4 位作者 刘吉斌 张缙熙 常欣 蔡胜 谭莉 《Chinese Medical Sciences Journal》 CAS CSCD 1999年第3期167-169,共3页
The purpose of this study was to determine the efficacy of using an ultrasound contrast agent(levovist)to enhance the color Doppler imaging of liver neoplasms.Thirty patients with hepatic tu... The purpose of this study was to determine the efficacy of using an ultrasound contrast agent(levovist)to enhance the color Doppler imaging of liver neoplasms.Thirty patients with hepatic tumors were enrolled in this study.After intravenous administration of levovist,the color Doppler signals of normal hepatic vessels were enhanced.In various hepatic tumors,the different patterns of tumor vascularity were observed,which had not been demonstrated in conventional non contrast color Doppler imaging.In 11 of 16 patients with hepatocarcinoma,additional color Doppler signals were observed in the central part of the tumors.On the contrary,3 patients with metastatic liver lesions the enhanced color Doppler signals appear only at the peripheral of tumors.A typical rim like color enhancement was seen in 2 of the 3 cases.In six patients with hepatic hemangiomas contrast enhanced color Doppler imaging demonstrated the blood vessels at the margin of the neoplasms.Contrast enhanced color Doppler imaging improves the visualization of the hepatic neoplasm vascularity.This technique holds great promise for detecting small liver tumors and differentiating hepatic neoplasms. 展开更多
关键词 ultrasound contrast agent color doppler imaging liver neoplasms
下载PDF
Clinical Evaluation of Color Doppler Ultrasound in Selecting the Optimal Treatment Modality for Infantile Hemangioma 被引量:6
7
作者 MinLi JuanLiu +2 位作者 ValeskaMaya DanLuo Bingrong Zhou 《Chinese Medical Sciences Journal》 CAS CSCD 2017年第2期100-106,共7页
Objective We investigated the efficacy and safety of 1064 nm Nd: YAG laser, intense pulsed light (IPL), and lauromacrogol injection in the treatment of hemangioma, in order to evaluate the value of color Doppler u... Objective We investigated the efficacy and safety of 1064 nm Nd: YAG laser, intense pulsed light (IPL), and lauromacrogol injection in the treatment of hemangioma, in order to evaluate the value of color Doppler ultrasound guidance in choosing the optimal treatment modality. Methods Infantile patients who were clinical diagnosed as hemangiomas were randomly divided into group A, who had color Doppler ultrasound examinations before the treatment, and group B who had the treatment without ultrasound evaluation. Patients in the group A were assigned into subgroups according to the depth of lesion by sonography: group A-1 for those who had a lesion depth 〈1.2 mm, and took intense pulsed light therapy; group A-2 for those who had a lesion depth ≥1.2mm and 〈 3 mm, and took long pulse 1064 nm Nd:YAG laser therapy; group A-3 for those who had a lesion depth ≥3mm and 〈5 mm, and were treated by IPL combined with long pulse 1064 nm Nd:YAG laser treatment; Group A-4 for those who had a lesion depth ≥5 mm, and took lauromacrogol injection therapy. Patients in the group B took long pulse 1064 nm Nd:YAG laser treatment without preoperative ultrasound evaluation. The efficacy and adverse reactions of the treatments between the groups were evaluated and compared statistically. Results Totally 113 patients with 128 skin lesions were enrolled in this study, 85 in the group A (mean age 6.8±7.9 months) and 28 in the group B (mean age 6.9±9.9 months). The mean depth of hemangioma was 3.3±1.1 mm in the group A, ranging from 0.5-7.8 mm, with 0.8±0.4 mm, 2.2±0.4 mm, 4.2±0.6 mm and 6.2±0.7 mm in group A1, A2, A3 and A4, respectively. The cure rates and effective rates in the group A were significantly higher than those in the group B (cure rates: 64.5% vs 56.3%, U=3.378, P=0.045; effective rates: 89.5% vs 78.1%, U=4.163, P=0.041). The adverse effect rates of the group A (vesicle 20.0%, pigmentation 46.9%, scarring 17.7%) were lower than those of the group B (vesicle 21.9%, pigmentation 60.4%, scarring 25.0%). Incidences of pigmentation and scarring were statistically significantly different (U=3.884, P=0.034, and U=4.016, P=0.032 respectively) between the two groups. Conclusion With the guidance of color Doppler ultrasound, the efficacy and safety of long pulse 1064 nmNd:YAG laser, intense pulsed light, and lauromacrogol injection in the treatment of infantile hemangioma have better outcomes compared to laser treatment alone without preoperative ultrasound examination. 展开更多
关键词 color doppler ultrasound infantile hemangioma Nd:YAG laser intense pulsed light LAUROMACROGOL
下载PDF
Pulsed Umbilical Artery Doppler Ultrasound Findings in Management of High-Risk Term Pregnant Women during Labour 被引量:2
8
作者 Noora E. Hamid Shahla K. Alalaf Namir G. Al-Tawil 《Open Journal of Obstetrics and Gynecology》 2017年第1期139-146,共8页
Purpose: Intrapartum Doppler velocimetry is a non-invasive investigation method. This method is useful for evaluating the pathophysiological mechanisms underlying changes in fetal heart rate. This study aimed to deter... Purpose: Intrapartum Doppler velocimetry is a non-invasive investigation method. This method is useful for evaluating the pathophysiological mechanisms underlying changes in fetal heart rate. This study aimed to determine the usefulness of Doppler ultrasound findings during labor in high-risk women on determining the mode of delivery and outcome of the newborn. Methods: A cross-sectional study was conducted from January 1, 2015 to December 31, 2015 on 100 high-risk pregnant women during labor. The study was performed in the Maternity Teaching Hospital in Erbil City, Kurdistan Region, Iraq. Results: The majority of women (77%) had a normal end-diastolic blood flow pattern through the umbilical artery. A total of 76.9% of those with abnormal Doppler results had a Cesarean delivery compared with only 9.5% of those with normal Doppler results (p p p = 0.07) and fifth minutes (p = 0.01). Conclusions: Abnormal umbilical artery Doppler ultrasound findings in high-risk pregnancies for women in labor are associated with increased rates of emergency cesarean sections and a poor outcome of the newborn. 展开更多
关键词 doppler ultrasound VELOCIMETRY Early NEONATAL DEATH UMBILICAL Artery
下载PDF
Pulse wave Doppler ultrasound of testicular arteries and their relationship with semen characteristics in healthy bulls 被引量:1
9
作者 Alessia Gloria Augusto Carluccio +3 位作者 Laura Wegher Domenico Robbe Claudio Valorz Alberto Contri 《Journal of Animal Science and Biotechnology》 SCIE CAS CSCD 2018年第2期319-325,共7页
Background: Semen evaluation is used to estimate the testicular function. In bulls, the spermatozoa present in the ejaculate are the result of a process that begun more than 2 mo earlier, bequeathing a delayed depicti... Background: Semen evaluation is used to estimate the testicular function. In bulls, the spermatozoa present in the ejaculate are the result of a process that begun more than 2 mo earlier, bequeathing a delayed depiction of the actual function of the testis. Since testis vascularization might be critical for the gonad function, selected pulse wave Doppler ultrasound parameters were assessed in this study, for instance the peak systolic velocity, the end diastolic velocity and the resistive index of the testicular artery along the spermatic cord, the marginal portion of the testicular artery and the intratesticular branches of the testicular artery both in healthy adult and young bulls.Correlations between these parameters and characteristics of semen that was collected numerous times, before and after the Doppler ultrasound examination.Results: The peak systolic velocity and the end diastolic velocity measured in the testicular artery along the spermatic cord(supratesticular artery – SA) were variable among the bulls and within individual bulls, likely due to the convoluted course of the vessel. The resistive index was found highly repeatable in the same bull. A reduction in the resistive index was found between the supratesticular artery and the marginal portion of the testicular artery(P < 0.01), and between the marginal portion of the testicular artery and the intratesticular branches of the testicular artery(P < 0.05). No differences were recorded for the pulse wave Doppler ultrasound parameters in young bulls compared with adults. A significant correlation was found between the resistive index of the marginal portion of the testicular artery and total sperm in the ejaculate(r = 0.516, P < 0.05), the immature sperm(r = 0.462, P < 0.05), the teratoid sperm(r = 0.375, P < 0.05), and the "Dag defect" sperm(r = 0.389, P < 0.05). Similarly, the resistive index of the intratesticular branches of the testicular artery were found correlated with the total sperm number in the ejaculate(r = 0.568, P < 0.05), the immature sperm(r = 0.523, P < 0.05), the teratoid sperm(r = 0.418, P < 0.05), and the "Dag defect" sperm(r = 0.341, P < 0.05).Conclusions: The data presented in this study suggest that the resistive index, measured at the marginal portion of the testicular artery, could be an easy-to-perform parameter to evaluate the spermatogenesis quality in young bulls and normal adults. 展开更多
关键词 BULL Pulse wave doppler SPERM morphology TESTIS ultrasound
下载PDF
Hemodynamic Changes on Color Doppler Flow Imaging and Intravenous Contrast-enhanced Ultrasound for Assessing Transplanted Liver and Early Diagnosis of Complications 被引量:1
10
作者 黄道中 陈云超 +1 位作者 李开艳 张青萍 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2008年第3期284-286,共3页
The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discu... The value of color Doppler flow imaging (CDFI) and intravenous contrast-enhanced ultrasound (CEUS) for assessing the transplanted liver and early diagnosing complications by examining hemodynamic changes was discussed. Seventy-five patients with orthotopic liver transplantation (OLT) underwent CDFI. The following parameters were measured: peak systolic velocity (PS), resistance index (RI) and Doppler perfusion index (DPI) of the hepatic artery (HA), time average velocity (TAV) of portal vein (PV) and velocity of hepatic vein (HV) in different stages postoperation, And 11 patients of them received CEUS. Thirty healthy subjects were enrolled as controls, The results showed that: (1) In 23 patients without obvious complications, TAV of PV within 15 days post-operation was significantly higher than in controls (P〈0.05), PS and DPI of HA within 7 days postoperation were lower, but RI was higher than in controls (P〈0.05); (2) When the hepatic artery thrombosis (HAT) occurred, PS and DPI of HA were obviously decreased, but TAV of PV significantly increased like a high saw-tooth wave; (3) While rejection occurred, both TAV of PV and PS of HA were decreased with the increase in RI of HA, and the triphasic wave of HV disappeared and displayed as saw-tooth wave; (4) The incidence of biliary complications in liver transplantation was increased when DPI was reduced; (5) Seven cases of hepatic carcinoma relapse after OLT demonstrated hyperecho in the arterial phase and hypoecho in the portal and later phase on CEUS; (6) In 2 cases of HA thrombus, there was no visualized enhancement in arterial phase of CEUS, but enhancement during the portal vein and parenchymal phase. It was concluded that the hemodynamic changes of PV, HA and HV in the transplanted liver are valuable for assessing the transplanted liver and early diagnosing complications on CDFI and CEUS. 展开更多
关键词 color doppler flow imaging liver transplantation HEMODYNAMICS postoperative complications intravenous contrast-enhanced ultrasound
下载PDF
The Diagnostic Value of Color Doppler Ultrasound and Grey Scale Sonography in Predicting the Malignancy of Thyroid Nodules 被引量:2
11
作者 Hamad Elniel H. Eltyib Sameh A. Aborizk +2 位作者 Hanan A. Albalawi Afaf S. Almotairi Arwa H. Aidrus 《Open Journal of Radiology》 2020年第4期215-222,共8页
Retrospective study was done at KAUH to determine the sonographic characteristics in predicting the malignancy of thyroid nodules. The sample was 120 patients consisting of 70 benign nodules and 50 malignant nodules. ... Retrospective study was done at KAUH to determine the sonographic characteristics in predicting the malignancy of thyroid nodules. The sample was 120 patients consisting of 70 benign nodules and 50 malignant nodules. Out of 120 patients, 106 (88.3%) female and 14 (11.7%) male patients. Out of 106 female patients, 64 (91.45) had benign and 42 had malignant thyroid nodules. Out of 14 (11.7) male patients, 6 had benign and 8 had malignant thyroid nodules. The youngest patient in our study was 31 years and the oldest patient was 76 years. The common range of patients age was ≥ 60 years and consisting of twenty (28.6%) benign thyroid nodules and fourteen (28%) malignant thyroid nodules. The majority of patients’ age group with malignant thyroid nodules were between 50 - 60 years and consisting of twenty (40%) malignant nodules. In our study, according to the result of gray scale and color Doppler ultrasonography, hypo-echogenicity, solid echo structure, micro-calcification and intra-nodular vascularity were the significant characteristics of malignancy in nodules with sensitivity (72%, 74%, 48% and 88% respectively), specificity (66%, 63%, 94% and 69% respectively), PPV (60%, 59%, 86% and 67% respectively) and NPV (77%, 77%, 72% and 89% respectively). 展开更多
关键词 ultrasound Thyroid Nodules MALIGNANT Color doppler Fine Needle Aspiration
下载PDF
Assessment of Uterine Receptivity by Endometrial and Subendometrial Blood Flows Measured by Vaginal Color Doppler Ultrasound in Women Undergoing IVF Treatment 被引量:1
12
作者 Min-zhi GAO Xiao-ming ZHAO +3 位作者 Wen-ying LI Gui-mei LIU Xiao-feng JIA Hui-qin ZHANG 《Journal of Reproduction and Contraception》 CAS 2007年第3期205-212,共8页
Objective To evaluate endometrial and subendometrial blood flows measured by vaginal color Doppler ultrasound as a predicator of endometrial receptivity in women undergoing IVF treatment. Methods A total of 119 infert... Objective To evaluate endometrial and subendometrial blood flows measured by vaginal color Doppler ultrasound as a predicator of endometrial receptivity in women undergoing IVF treatment. Methods A total of 119 infertile patients undergoing the first IVF/ICSI-ET cycle were recruited. Three groups were divided according to a color Doppler ultrasound examination performed on the day of hCG injection. Group A, endometrial and subendometrial blood flows were 2 branches and below; group B, endometrial and subendometrial blood flows were between 3 and 4 branches; group C, endometrial and subendometrial blood flows were 5 branches and above. Patients were transferred 1-3 embryos each. Demographic data, ovarian responses, endometrial thickness, PI, RI, development of embryo and IVF result among groups were compared. Results Demographic data, ovarian responses, endometrial thickness, PI, RI and development of embryo among groups have no significant difference. The pregnancy rate of group A was significantly lower than that of group B (P〈0.05) and group C (P〈0.01). The implantation rate of group A was significantly lower than than of group C (P〈0.01). There was no significant difference of the rate of pregnancy and implantation between group B and group C (P〉0.05). Conclusion Endometrial and subendometrial blood flows measured by vaginal color Doppler ultrasound is a good predicator of pregnancy during IVF treatment. A good endometrial and subendometrial blood flows is benefit for the result of IVF. 展开更多
关键词 endometrial and subendometrial blood flows endometrial receptivity in vitro fertilization-embryo transfer (IVF) color doppler ultrasound
下载PDF
Point of care venous Doppler ultrasound: Exploring the missing piece of bedside hemodynamic assessment 被引量:5
13
作者 Pablo Galindo Carlos Gasca +1 位作者 Eduardo R Argaiz Abhilash Koratala 《World Journal of Critical Care Medicine》 2021年第6期310-322,共13页
Accurate assessment of the hemodynamic status is vital for appropriate management of patients with critical illness.As such,there has been a constant quest for reliable and non-invasive bedside tools to assess and mon... Accurate assessment of the hemodynamic status is vital for appropriate management of patients with critical illness.As such,there has been a constant quest for reliable and non-invasive bedside tools to assess and monitor circulatory status in order to ensure end-organ perfusion.In the recent past,point of care ultrasonography(POCUS)has emerged as a valuable adjunct to physical examination in various specialties,which basically is a clinician-performed bedside ultrasound to answer focused questions.POCUS allows visualization of the internal anatomy and flow dynamics in real time,guiding apt interventions.While both arterial(forward flow)and venous(organ outflow or afterload)limbs of hemodynamic circuit are important for tissue perfusion,the venous side remains relatively under-explored.With recent data underscoring the deleterious consequences of iatrogenic volume overload,objective evaluation of venous congestion is gaining attention.Bedside Doppler ultrasound serves this purpose and aids in diagnosing and monitoring the congestion/venous blood flow pattern.In this article,we summarize the rationale for integrating this technology into routine care of patients with volume-related disorders,discuss the normal and abnormal waveforms,limitations,and future directions. 展开更多
关键词 ultrasound Point of care ultrasonography doppler VExUS Congestion HEMODYNAMICS Heart failure NEPHROLOGY Critical care
下载PDF
Doppler Ultrasound Abnormalities of the Lower Limbs in Patients with Diabetic Foot at the Yopougon University Hospital in Ivory Coast 被引量:1
14
作者 Kossi Kodjo Mamadou Mansour Diallo +5 位作者 Alpha Mamadou Diallo Koffi Pierre Dago Adelaide Hue Assita Yao Abodo Jacko Adrien Lokrou 《Open Journal of Endocrine and Metabolic Diseases》 2022年第5期113-121,共9页
Background: Diabetic foot is a frequent complication of diabetes, of multifactorial origin, associating nervous and/or circulatory disorders to which infection is often added. Its care is multidisciplinary and require... Background: Diabetic foot is a frequent complication of diabetes, of multifactorial origin, associating nervous and/or circulatory disorders to which infection is often added. Its care is multidisciplinary and requires coordination between different actors. In this context, arterial doppler ultrasound is essential in the diagnosis of diabetic arteriopathy and participates in therapeutic decision-making. The aim of this study was to describe the abnormalities found on Doppler ultrasonography of patients hospitalized for the diabetic foot in the Ivory Coast. Methods: We conducted a retrospective descriptive study including 235 patients hospitalized for the diabetic foot in the Endocrinology department of the Yopougon University Hospital from February 2002 to December 2015. All records of patients who performed arterial Doppler ultrasound of the lower limbs were selected and the various abnormalities were described. Results: The sex ratio (M/F) was 1.1 (124 men to 111 women). The predominant age group was 61.2 years. Type 2 diabetes was found in 97.4% of cases. The average evolution of diabetes was 8.9 years with extremes of 1 and 32 years. Wet gangrene was the most common type of lesion found in 75.8% of cases. On ultrasonography, 98.7% of the patients had an arterial abnormality of the lower limbs. It was bilateral in 62.2% of cases, dominated by atheromatous overloads and mediacalcosis in 46.4% and 43.8% of cases, respectively. Arterial stenosis was lesions hemodynamically found in 76.3% of cases and arterial occlusions in 32.7% of cases. The amputation rate was 72.7%. Conclusion: This study shows the high frequency of arterial abnormalities in patients with the diabetic foot with a predominantly distal involvement. Arterial Doppler ultrasound of the lower limbs remains an essential tool in the care of diabetic foot. This easily accessible, non-invasive examination has a key role in therapeutic decision-making. 展开更多
关键词 DIABETES Arterial doppler ultrasound ARTERIOPATHY Ivory Coast
下载PDF
Early warning study of color doppler ultrasound in children with thyroid nodules and thyroid cancer 被引量:1
15
作者 Li Yang Wen-Qi Ma +1 位作者 Bai-Ling Liu Qi Zhou 《Journal of Hainan Medical University》 2019年第9期66-69,共4页
Objective: To study the diagnostic value of color doppler ultrasound in children with thyroid nodules and thyroid cancer. Methods: A total of sixty children with thyroid nodules treated in our hospital from March 2017... Objective: To study the diagnostic value of color doppler ultrasound in children with thyroid nodules and thyroid cancer. Methods: A total of sixty children with thyroid nodules treated in our hospital from March 2017 to March 2018 were selected for study. All patients underwent color Doppler ultrasound diagnosis. According to the diagnostic data, benign thyroid nodules and thyroid cancer were analyzed. The nodule nature was grouped into benign nodules group and malignant nodules group. The aspect ratio and boundary of the two groups were compared in blurring, calcification, blood flow signal classification, etc. Results: A total of 95 nodules were diagnosed by color doppler ultrasonography in 60 cases of thyroid nodules. 49 cases were benign nodules. There were 80 nodules, accounting for 82.11%, 11 cases of thyroid cancer, and 15 nodules. Accounted for 15.79%. Biopsy puncture pathology confirmed 77 benign nodules and 18 malignant nodules. The pathological results were gold standard. The specificity of color Doppler ultrasound was 90%, the sensitivity was 66.67%, and the accuracy of ultrasound diagnosis was 86.32%.The two nodules were statistically significant in terms of boundary, aspect ratio, calcification, echo, and resistance index (P<0.05), but the end-diastolic blood flow velocity (EDV) and peak systolic blood flow velocity ( There was no statistical difference between the PSV levels (P>0.05).Conclusion: Color Doppler ultrasound has the advantages of simple operation, high accuracy, non-invasive and painless, and reproducible detection. The high-frequency probe can clearly display changes such as minute lesions, blood flow signals, echoes, calcifications, etc., and can diagnose thyroid cancer in time. It provides a favorable basis for clinical treatment and has important clinical warning value, especially for children with thyroid examination. 展开更多
关键词 THYROID NODULES Color doppler ultrasound PEDIATRIC THYROID cancer Early WARNING
下载PDF
Application and prospects of AI-based radiomics in ultrasound diagnosis 被引量:1
16
作者 Haoyan Zhang Zheling Meng +2 位作者 Jinyu Ru Yaqing Meng Kun Wang 《Visual Computing for Industry,Biomedicine,and Art》 EI 2023年第1期288-303,共16页
Artificial intelligence (AI)-based radiomics has attracted considerable research attention in the field of medical imaging, including ultrasound diagnosis. Ultrasound imaging has unique advantages such as high tempora... Artificial intelligence (AI)-based radiomics has attracted considerable research attention in the field of medical imaging, including ultrasound diagnosis. Ultrasound imaging has unique advantages such as high temporal resolution, low cost, and no radiation exposure. This renders it a preferred imaging modality for several clinical scenarios. This review includes a detailed introduction to imaging modalities, including Brightness-mode ultrasound, color Doppler flow imaging, ultrasound elastography, contrast-enhanced ultrasound, and multi-modal fusion analysis. It provides an overview of the current status and prospects of AI-based radiomics in ultrasound diagnosis, highlighting the application of AI-based radiomics to static ultrasound images, dynamic ultrasound videos, and multi-modal ultrasound fusion analysis. 展开更多
关键词 Radiomics ultrasound imaging Artificial intelligence Deep learning B-mode ultrasound Color doppler flow imaging ultrasound elastography Contrast-enhanced ultrasound Multimodal ultrasound
下载PDF
Emboli detection using the Doppler ultrasound technique
17
作者 WANG Yuanyuan, CHEN Xi, ZHANG Yu, WANG Weiqi (Department of Electronic Engineering, Fudan University,Shanghai 200433,China) 《声学技术》 CSCD 2003年第z1期15-18,共4页
Embolic detection is very important to the early diagnosis of vessel disease. The Doppler ultrasound technique is one of the common methods to detect the emboli non-invasively. When the emboli pass through the sample ... Embolic detection is very important to the early diagnosis of vessel disease. The Doppler ultrasound technique is one of the common methods to detect the emboli non-invasively. When the emboli pass through the sample volume of the Doppler ultrasound instrument, there exist high intensity transient Doppler signals. Thus the emboli can be detected directly from the variation of Doppler signal amplitude. Since there may be some disturbance in the system, this general detection method has great limitation. To improve the accuracy of emboli auto-detection, several novel methods are studied to obtain the sensitive characteristic of the emboli signals using the new signal processing theories. 展开更多
关键词 EMBOLIC signal doppler ultrasound detection
下载PDF
Measurement of Liver Size and Intrahepatic Blood Flow of Red-eared Turtles by Color Doppler Ultrasound
18
作者 Cheng Yu Xie Fuqiang 《Animal Husbandry and Feed Science》 CAS 2015年第4期246-248,共3页
In the study, a total of 20 red-eared turtles ( half male and half female) were selected to conduct the measurement of liver size and intrahepatic blood flow of red-eared turtles by color Doppler ultrasound. The res... In the study, a total of 20 red-eared turtles ( half male and half female) were selected to conduct the measurement of liver size and intrahepatic blood flow of red-eared turtles by color Doppler ultrasound. The results showed that the fight hepatic lobe could be scanned through the right carotid anterior acoustic win- dow, and the left hepatic lobe could be scanned through the left carotid anterior acoustic window, but the vision would be obstructed by the air in trachea. The liver could also be scanned through the left femoral anterior acoustic window and the fight femoral anterior acoustic window when filling of bladder was good. The correla- tion regression analysis suggested that estimated values of liver showed no linear relationship with weight, the longest back curve and the widest back curve. Through the study, the normal indicators for ultrasound examination of red-eared turtle liver were established, in order to provide a reference for examination of turtle liver. 展开更多
关键词 Red-eared turtle Color doppler ultrasound LIVER Blood flow
下载PDF
A Fertility Assessment of Infertile Men with Varicocele by Means of Doppler Ultrasound
19
作者 王益鑫 薄隽杰 +3 位作者 黄旭元 钱宪明 冷静 韩银发 《Journal of Reproduction and Contraception》 CAS 1997年第2期85-91,共7页
The diameters of spermatic veins and blood reflux in sixty-two male patients with infertility caused by varicocele were assessed with Doppler ultrasound in this study. Scrotal thermograph, testes volume and semen anal... The diameters of spermatic veins and blood reflux in sixty-two male patients with infertility caused by varicocele were assessed with Doppler ultrasound in this study. Scrotal thermograph, testes volume and semen analysis were also applied to analysis of these patients. Among sixty-two patients, thirty-one received high ligation of internal spermatic vein. The results showed: 1. The diameter of spermatic veins was negatively correlated with fertility index and positively correlated with Doppler grading of blood reflux. 2. In operative patients, the effect of surgery was better in patients with blood reflux than in those without blood reflux. It was suggested the diameter of spermatic veins probably reflects the duration and serious degree of blood reflux in spermatic vein, and may be used for assessment of severity of male infertility in combination with semen analysis. 展开更多
关键词 doppler ultrasound Fertility assessment Infertile men Varicocele
下载PDF
Assessment of voluntary rhythmic muscle contraction-induced exercising blood flow variability measured by Doppler ultrasound 被引量:1
20
作者 Takuya Osada Bengt Saltin Goran Radegran 《Open Journal of Molecular and Integrative Physiology》 2013年第4期158-165,共8页
Given recent technological developments, ultrasound Doppler can provide valuable measurements of blood velocity/flow in the conduit artery with high temporal resolution. In human-applied science such as exercise physi... Given recent technological developments, ultrasound Doppler can provide valuable measurements of blood velocity/flow in the conduit artery with high temporal resolution. In human-applied science such as exercise physiology, hemodynamic measurements in the conduit artery is commonly performed by blood flow feeding the exercising muscle, as the increase in oxygen uptake (calculated as a product of arterial blood flow to the exercising limb and the arterio-venous oxygen difference) is directly proportional to the work performed. The increased oxygen demand with physical activity is met through a central mechanism, an increase in cardiac output and blood pressure, as well as a peripheral mechanism, an increase in vascular conductance and oxygen extraction (a major part of the whole exercising muscles) from the blood. The increase in exercising muscle blood flow in relation to the target workload (quantitative response) may be one indicator in circulatory adjustment for the ac- tivity of muscle metabolism. Therefore, the determination of local blood flow dynamics (potential oxygen supply) feeding repeated (rhythmic) muscle contractions can contribute to the understanding of the factors limiting work capacity including, for instance, muscle metabolism, substance utilization and magnitude of vasodilatation in the exercising muscle. Using non-invasive measures of pulsed Doppler ultrasound, the validity of blood velocity/flow in the forearm or lower limb conduit artery feeding to the muscle has been previously demonstrated during rhythmic muscle exercise. For the evaluation of exercising blood flow, not only muscle contraction induced internal physiological variability, or fluctuations in the magnitude of blood velocity due to spontaneous muscle contraction and relaxation induced changes in force curve intensity, superimposed in cardiac beat-by-beat, but also the alterations in the blood velocity (external variability) due to a temporary sudden change in the achieved workload, compared to the target workload, should be considered. Furthermore, a small amount of inconsistency in the voluntary muscle contraction force at each kick seems to be unavoidable, and may influence exercising muscle blood flow, although subjects attempt to perform precisely similar repeated voluntary muscle contractions at target workload (muscle contraction force). This review presents the methodological considerations for the variability of exercising blood velocity/flow in the limb conduit artery during dynamic leg exercise assessed by pulsed Doppler ultrasound in relation to data previously reported in original research. 展开更多
关键词 Exercising Blood Flow doppler ultrasound Muscle Contraction Blood Flow Alterations
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部