期刊文献+
共找到6,714篇文章
< 1 2 250 >
每页显示 20 50 100
Biomechanical effects of posterior lumbar interbody fusion with vertical placement of pedicle screws compared to traditional placement
1
作者 Ji-Hong Jiang Chang-Ming Zhao +2 位作者 Jun Zhang Rong-Ming Xu Lei Chen 《World Journal of Clinical Cases》 SCIE 2024年第20期4108-4120,共13页
BACKGROUND The pedicle screw technique is widely employed for vertebral body fixation in the treatment of spinal disorders.However,traditional screw placement methods require the dissection of paraspinal muscles and t... BACKGROUND The pedicle screw technique is widely employed for vertebral body fixation in the treatment of spinal disorders.However,traditional screw placement methods require the dissection of paraspinal muscles and the insertion of pedicle screws at specific transverse section angles(TSA).Larger TSA angles require more force to pull the muscle tissue,which can increase the risk of surgical trauma and ischemic injury to the lumbar muscles.AIM To study the feasibility of zero-degree TSA vertical pedicle screw technique in the lumbosacral segment.METHODS Finite element models of vertebral bodies and pedicle screw-rod systems were established for the L4-S1 spinal segments.A standard axial load of 500 N and a rotational torque of 10 N/m were applied.Simulated screw pull-out experiment was conducted to observe pedicle screw resistance to pull-out,maximum stress,load-displacement ratio,maximum stress in vertebral bodies,load-displacement ratio in vertebral bodies,and the stress distribution in pedicle screws and vertebral bodies.Differences between the 0-degree and 17-degree TSA were compared.RESULTS At 0-degree TSA,the screw pull-out force decreased by 11.35%compared to that at 17-degree TSA(P<0.05).At 0-degree and 17-degree TSA,the stress range in the screw-rod system was 335.1-657.5 MPa and 242.8-648.5 MPa,separately,which were below the fracture threshold for the screw-rod system(924 MPa).At 0-degree and 17-degree TSA,the stress range in the vertebral bodies was 68.45-78.91 MPa and 39.08-72.73 MPa,separately,which were below the typical bone yield stress range for vertebral bodies(110-125 MPa).At 0-degree TSA,the load-displacement ratio for the vertebral bodies and pedicle screws was slightly lower compared to that at 17-degree TSA,indicating slightly lower stability(P<0.05).CONCLUSION The safety and stability of 0-degree TSA are slightly lower,but the risks of screw-rod system fracture,vertebral body fracture,and rupture are within acceptable limits. 展开更多
关键词 Vertical pedicle screw pedicle screw technique Transverse section angle Lumbosacral segment Finite element analysis
下载PDF
Revised in-depth meta-analysis on the efficacy of robot-assisted versus traditional free-hand pedicle screw insertion
2
作者 Sorayouth Chumnanvej Branesh M.Pillai +1 位作者 Jackrit Suthakorn Siriluk Chumnanvej 《Laparoscopic, Endoscopic and Robotic Surgery》 2024年第4期155-165,共11页
Objective:Robot-assisted pedicle screw insertion has recently emerged as an alternative to the traditional free-hand technique.However,discrepancies in the accuracy of screw placement between the 2 methods have been h... Objective:Robot-assisted pedicle screw insertion has recently emerged as an alternative to the traditional free-hand technique.However,discrepancies in the accuracy of screw placement between the 2 methods have been highlighted by some comparative studies.This meta-analysis was conducted to synthesize evidence comparing these techniques.Methods:Searches were conducted in 5 electronic databases adhering to specific eligibility criteria for randomized and observational studies.The data were analyzed using RevMan software and the results are presented as odds ratios(ORs),mean differences,or standard mean differences(SMDs)with 95%confidence intervals(CIs).Our analysis included 12 studies(7 randomized trials and 5 observational studies,involving 883 patients and 4903 screws).Results:The results demonstrated a higher rate of Grade A Gertzbein and Robbins pedicle placement score(OR:1.77;95%CI:1.10e2.87),a lower rate of revision surgeries(OR:0.21;95%CI:0.09e0.52),and a shorter radiation exposure duration(SMD?1.38,95%CI:2.32 to0.44)in the robot-assisted group compared with the free-hand group.Nonetheless,the length of hospital stay,volume of intraoperative blood loss,postoperative visual analogue scale scores for back pain,and rate of wound infection were similar between the 2 groups.Significant heterogeneity was observed in some outcomes.Conclusion:Compared with the free-hand method,the robot-assisted technique provides greater accuracy and reduced radiation exposure.The efficacy of the robot-assisted technique is expected to improve further as experience with its use in surgery grows. 展开更多
关键词 Robotic surgery pedicle screw placement FREE-HAND FLUOROSCOPY META-ANALYSIS
下载PDF
Preliminary study on the efficacy of lacrimal duct reconstruction with pedicled conjunctival flap in the treatment of severe lacrimal canalicular obstruction with conjunctivochalasis
3
作者 Gao-Xiang Ouyang Fang Bai Hai Tao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第4期539-546,共8页
AIM:To determine the efficacy and safety of pedicled conjunctival lacrimal duct reconstruction in the treatment of severe obstruction of superior and inferior lacrimal canaliculi with conjunctivochalasis.METHODS:This ... AIM:To determine the efficacy and safety of pedicled conjunctival lacrimal duct reconstruction in the treatment of severe obstruction of superior and inferior lacrimal canaliculi with conjunctivochalasis.METHODS:This study was per formed as a retrospective analysis of patients who received conjunctival dacryocystorhinostomy with pedicled conjunctival flap reconstruction combined with tube intubation due to severe superior and inferior lacrimal canalicular obstruction with conjunctivochalasis from January 2019 to October 2019.The clinical data included the degree of preoperative epiphora and postoperative relief,preoperative examination of lacrimal duct computed tomography and ultrasound biomicroscopy,postoperative evaluation of lacrimal duct function by chloramphenicol taste and fluorescein dye disappearance test,etc.Syringing was carried out to determine the reconstruction and patency of the lacrimal duct.RESULTS:All 9 patients(9 eyes)had severe canalicular obstruction with conjunctivochalasis.The patients included 4 males and 5 females aged between 47–65y with an average age of 52.2±6.7y.At 3mo follow-up,the tube was removed and the patients were followed for a further 3mo.After tube removal,6 patients showed no epiphora.These patients also had positive chloramphenicol tastes and normal fluorescein dye disappearance test results.Two patientshad epiphora.Also,syringing showed partial patency of the reconstructed lacrimal duct.One patient had no improvement in epiphora with negative chloramphenicol taste and fluorescein dye disappearance test results and obstruction of the reconstructed lacrimal duct.The total effective rate of the operation was 8/9,with no serious complications.CONCLUSION:Pedicled conjunctival lacrimal duct reconstruction conjunctival dacryocystorhinostomy is safe and effective for superior and inferior canalicular obstruction with conjunctivochalasis. 展开更多
关键词 EPIPHORA severe lacrimal canalicular obstruction conjunctival dacryocystorhinostomy pedicled conjunctival flap reconstruction CONJUNCTIVOCHALASIS
下载PDF
Comparison of Sternal Wound Complication after Off-Pump CABG between Skeletonized and Pedicled LIMA Harvesting: A Single Centre Experience in Bangladesh
4
作者 M. Asmaul Alam Al Nur Md. Aslam Hossain +2 位作者 Md. Abir Tazim Chowdhury Farhat Tabassum Nishat Munama Magdum 《World Journal of Cardiovascular Surgery》 2023年第6期101-110,共10页
Background: Off-pump coronary artery bypass grafting (OPCAB) is a surgical procedure that has gained popularity due to its potential benefits over traditional coronary artery bypass grafting, including reduced morbidi... Background: Off-pump coronary artery bypass grafting (OPCAB) is a surgical procedure that has gained popularity due to its potential benefits over traditional coronary artery bypass grafting, including reduced morbidity and mortality. However, sternal wound complication (SWC) remains challenging following the procedure. The technique of left internal mammary artery (LIMA) harvesting has been shown to impact the incidence of SWC. This study aimed to compare the incidence of SWC between two techniques of LIMA harvesting, i.e., skeletonized and pedicled. Methods: The study was conducted at the Department of Cardiac Surgery, Bangabandhu Sheikh Mujib Medical University, and included 60 patients who underwent OPCAB. The patients were divided into two groups of 30 each based on the technique of LIMA harvesting used, i.e., skeletonized (group A) or pedicled (group B). The postoperative ICU care was given to each patient as per the protocol. The statistical analysis was conducted using the SPSS version 26.0 for Windows software. Results: The results showed that 5 (8.33%) patients developed SWC, with 1 (1.67%) patient in group A and 4 (6.66%) patients in group B. However, the occurrence of SWC was not statistically significant between the two groups (p = 0.35). The mean age, gender distribution, and comorbidities such as hypertension, diabetes, dyslipidemia, and anemia were also not statistically significant between the two groups. The number of smokers was statistically significant between the two groups (p = 0.03), and the occurrence of SWC was found to be higher in smoker patients in group B (p = 0.04). Preoperative and postoperative parameters such as duration of operation, duration of mechanical ventilation, duration of chest drains, duration of the central venous line, and amount of postoperative mediastinal bleeding were also not statistically significant between the two groups. The distribution of wound complications, duration of ICU stays, and hospital stay between the two groups was also not statistically significant. Conclusion: In conclusion, this study found that the incidence of SWC was less in skeletonized LIMA harvesting than in pedicled LIMA harvesting after OPCAB. However, this finding was not statistically significant. Further studies with larger sample sizes may be needed to confirm these results and determine the appropriate technique of LIMA harvesting to decrease the incidence of SWC after OPCAB. 展开更多
关键词 Sternal Wound Complication (SWC) Off-Pump Coronary Artery Bypass Grafting (OPCAB) Left Internal Mammary Artery (LIMA) Skeletonized LIMA Harvesting pedicle LIMA Harvesting
下载PDF
Position and complications of pedicle screw insertion with or without image-navigation techniques in the thoracolumbar spine:a meta-analysis of comparative studies 被引量:16
5
作者 Jinshan Tang Ziqiang Zhu +2 位作者 Tao Sui Dechao Kong Xiaojian Cao 《The Journal of Biomedical Research》 CAS 2014年第3期228-239,共12页
Computer-navigated pedicle screw insertion is applied to the thoracic and lumbar spine to attain high insertion accuracy and a low rate of screw-related complications.However,some in vivo and in vitro studies have sho... Computer-navigated pedicle screw insertion is applied to the thoracic and lumbar spine to attain high insertion accuracy and a low rate of screw-related complications.However,some in vivo and in vitro studies have shown that no advantages are gained with the use of navigation techniques compared to conventional techniques.Additionally,inconsistent conclusions have been drawn in various studies due to different population characteristics and methods used to assess the accuracy of screw placement.Moreover,it is not clear whether pedicle screw insertion with navigation techniques decreases the incidence of screw-related complications.Therefore,this study was sought to perform a meta-analysis of all available prospective evidence regarding pedicle screw insertion with or without navigation techniques in human thoracic and lumbar spine.We considered in vivo comparative studies that assessed the results of pedicle screw placement with or without navigation techniques.PubMed,Ovid MEDLINE and EMBASE databases were searched.Three published randomized controlled trials(RCTs) and nine retrospective comparative studies met the inclusion criteria.These studies included a total of 732 patients in whom 4,953 screws were inserted.In conclusion,accuracy of the position of grade I,II,III and IV screws and complication rate related to pedicle screw placement were significantly increased when navigation techniques were used in comparison to conventional techniques.Future research in this area should include RCTs with well-planned methodology to limit bias and report on validated,patient-based outcome measures. 展开更多
关键词 META-ANALYSIS POSITION pedicle screw insertion navigation COMPLICATION
下载PDF
Treatment of Thoracolumbar Vertebrate Fracture by Transpedicular Morselized Bone Grafting in Vertebrae for Spinal Fusion and Pedicle Screw Fixation 被引量:16
6
作者 王金国 吴华 +1 位作者 丁晓琳 刘玉田 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2008年第3期322-326,共5页
To enhance the fusion of graft bone in thoracolumbar vertebrae and minimize the postoperative loss of correction, short-segment pedicle screw fixation was reinforced with posterior moselizee bone grafting in vertebrae... To enhance the fusion of graft bone in thoracolumbar vertebrae and minimize the postoperative loss of correction, short-segment pedicle screw fixation was reinforced with posterior moselizee bone grafting in vertebrae for spinal fusion in patients with thoracrolumbar vertebrate fractures. Seventy patients with thoracrolumbar vertebrate fractures were treated by short-segment pedicle screw fixation and were randomly divided into two groups. Fractures in group A (n=20) were rein-forced with posterior morselized bone grafting in vertebrae for spinal fusion, while patients group B (n=50) did not receive the morselized bone grafting for bone fusion. The two groups were compared in terms of kyphotic deformity, anterior vertebral height, instrument failure and neurological functions after the treatment. Frankel grading system was used for the evaluation of neurological evaluation and Denis scoring scale was employed for pain assessment. The results showed that the kyphosis correction was achieved in both group A and group B (group A: 6.4 degree; group B: 5.4 degree)/At the end of follow-up, kyphosis correction was maintained in group A but lost in group B (P=0.0001). Postoperatively, greater anterior height was achieved in group A than in group B (P〈0.01). During follow-up study, anterior vertebral height was maintained only in Group A (P〈0.001). Both group A and group B showed good Denis pain scores (P1 and P2) but group A outdid group B in terms of control of severe and constant pain (P4 and P5). By Frankel criteria, the changes in neurological functions in group A was better than those of group B (P〈0.001). It is concluded that reinforcement of short-segment pedicle fixation with morselized bone grafting for the treatment of patients with thoracolumbar vertebrae fracture could achieve and maintain kyphosis correction, and it may also increase and maintain anterior vertebral height. Morselized bone grafting in vertebrae offers immediate spinal stability in patients with thoracolumbar vertebrate fractures, decreases the instrument failure and provides better postoperative pain control than without the morselized bone grafting. 展开更多
关键词 thoracolumbar vertebrae fracture kyphotic deformity pedicle screw morselized bone grafting in vertebrae
下载PDF
Techniques and accuracy of thoracolumbar pedicle screw placement 被引量:8
7
作者 Varun Puvanesarajah Jason A Liauw +2 位作者 Sheng-fu Lo Ioan A Lina Timothy F Witham 《World Journal of Orthopedics》 2014年第2期112-123,共12页
Pedicle screw instrumentation has been used to stabilize the thoracolumbar spine for several decades. Although pedicle screws were originally placed via a freehand technique, there has been a movement in favor of pedi... Pedicle screw instrumentation has been used to stabilize the thoracolumbar spine for several decades. Although pedicle screws were originally placed via a freehand technique, there has been a movement in favor of pedicle screw placement with the aid of imaging. Such assistive techniques include fluoroscopy guidance and stereotactic navigation. Imaging has the benefit of increased visualization of a pedicle's trajectory, but can result in increased morbidity associated with radiation exposure, increased time expenditure, and possible workflow interruption. Many institutions have reported high accuracies with each of these three core techniques. However, due to differing definitions of accuracy and varying radiographic analyses, it is extremely difficult to compare studies side-by-side to determine which techniques are superior. From the literature, it can be concluded that pedicles of vertebrae within the mid-thoracic spine and vertebrae that have altered morphology due to scoliosis or other deformities are the most difficult to cannulate. Thus, spine surgeons would benefit the most from using assistive technologies in these circumstances. All other pedicles in thethoracolumbar spine should theoretically be cannulated with ease via a free-hand technique, given appropriate training and experience. Despite these global recommendations, appropriate techniques must be chosen at the surgeon's discretion. Such determinations should be based on the surgeon's experience and the specific pathology that will be treated. 展开更多
关键词 THORACIC VERTEBRAE LUMBAR VERTEBRAE pedicle screw FLUOROSCOPY COMPUTED tomography
下载PDF
A new free-hand pedicle screw placement technique with reference to the supraspinal ligament 被引量:7
8
作者 Juming Li Hong Zhao +7 位作者 Hao Xie Lipeng Yu Jifu Wei Min Zong Feng Chen Ziqiang Zhu Ning Zhang Xiaojian Cao 《The Journal of Biomedical Research》 CAS 2014年第1期64-70,共7页
We sought to compare the safety and accuracy of a new free-hand pedicle screw placement technique to that of the conventional technique. One hundred fifty-three consecutive adult patients with simple fracture in the t... We sought to compare the safety and accuracy of a new free-hand pedicle screw placement technique to that of the conventional technique. One hundred fifty-three consecutive adult patients with simple fracture in the tho- racic or/and lumbar spine were alternately assigned to either the new free-hand or the conventional group. In the new free-hand technique group, preoperative computerized tomography (CT) images were used to calculate the targeted medial-lateral angle of each pedicle trajectory and the pedicle screw was inserted perpendicular to the corresponding supraspinal ligament. In the conventional technique group, the medial-lateral and cranial-caudal angle of each pedicle trajectory was determined by intraoperatively under fluoroscopic guidance. The accuracy rate of pedicle screw placement, the time of intraoperative fluoroscopy, the operating time and the amount of blood loss during operation were respectively compared. All screws were analyzed by using intraoperative ra- diographs, intraoperative triggered electromyography (EMG) monitoring data, postoperative CT data and clinical outcomes. The accuracy rate of pedicle screw placement in the new free-hand technique group and the conven- tional technique group was 96.3% and 94.2% (P 〈 0.05), respectively. The intraoperative fluoroscopy time of the new technique group was less than that of the conventional technique group (5.37 seconds vs. 8.79 seconds, P 〈 0.05). However, there was no statistical difference in the operating time and the amount of blood loss during op- eration (P 〉 0.05). Pedicle screw placement with the free-hand technique which keeps the screw perpendicular to the supraspinal ligament is an accurate, reliable and safe technique to treat simple fracture in the thoracic or lum- bar spine. 展开更多
关键词 spine fracture pedicle screw placement radiation exposure supraspinal ligament anatomy reference
下载PDF
Clinical outcomes with large macular holes using the tiled transplantation internal limiting membrane pedicle flap technique 被引量:3
9
作者 Li-Ping Wang Wen-Tao Sun +1 位作者 Chun-Ling Lei Jin Deng 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2019年第2期246-251,共6页
AIM: To report the surgical technique and efficacy of the tiled transplantation internal limiting membrane(ILM) pedicle flap technique after vitrectomy for 33 patients with large macular hole(MH). METHODS: This study... AIM: To report the surgical technique and efficacy of the tiled transplantation internal limiting membrane(ILM) pedicle flap technique after vitrectomy for 33 patients with large macular hole(MH). METHODS: This study was a prospective noncontrolled interventional study. All patients were treated by vitrectomy, the tiled transplantation ILM pedicle flap and gas tamponade. All patients underwent visual acuity measurements and optical coherence tomography(OCT), during preoperative and the follow-up visits postoperative. RESULTS: Two high-myopic patient had flap dislocation during surgery. The thorough closure of MH following the tiled transplantation ILM pedicle flap technique was ultimately achieved in 31 patients observed by OCT imaging(93.94%) 1 wk after surgery. Visual acuity improved from 1.51±0.31(logMAR) preoperative to 0.92±0.30 6 mo after surgery(P=0.000). There were no significant changes in OCT finding during the follow-up period from 1 mo to 6 mo after surgery. CONCLUSION: The tiled transplantation ILM pedicle flap technique provides bridge for retinal gliosis to achieve successful closures of the large MHs, and the microenvironment of this technique is more similar to the normal physiological conditions. 展开更多
关键词 tiled TRANSPLANTATION ILM pedicle FLAP MACULAR hole VITRECTOMY
下载PDF
Role of adipose-derived stromal cells in pedicle skin flap survival in experimental animal models 被引量:4
10
作者 Pericles Foroglou Vasileios Karathanasis +2 位作者 Efterpi Demiri George Koliakos Marios Papadakis 《World Journal of Stem Cells》 SCIE CAS 2016年第3期101-105,共5页
The use of skin flaps in reconstructive surgery is the first-line surgical treatment for the reconstruction of skin defects and is essentially considered the starting point of plastic surgery. Despite their excellent ... The use of skin flaps in reconstructive surgery is the first-line surgical treatment for the reconstruction of skin defects and is essentially considered the starting point of plastic surgery. Despite their excellent usability, their application includes general surgical risks or possible complications, the primary and most common is necrosis of the flap. To improve flap survival, researchers have used different methods, including the use of adiposederived stem cells, with significant positive results. In our research we will report the use of adipose-derived stem cells in pedicle skin flap survival based on current literature on various experimental models in animals. 展开更多
关键词 pedicle SKIN FLAP Adipose STROMAL cells FLAP SURVIVAL Stem cell SKIN defect RECONSTRUCTIVE surgery
下载PDF
Pedicle Screw Fixation with Kyphoplasty Decreases the Fracture Risk of the Treated and Adjacent Non-treated Vertebral Bodies:a Finite Element Analysis 被引量:4
11
作者 Pan YANG Ying ZHANG +7 位作者 Huan-wen DING Jian LIU Lin-qiang YE Jin XIAO Qiang TU Tao YANG Fei WANG Guo-gang SUN 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2016年第6期887-894,共8页
Adjacent vertebral fractures are common in patients with osteoporotic vertebral compression fractures(OVCFs) after kyphoplasty.This finite element study was to examine whether short segment pedicle screw fixation(... Adjacent vertebral fractures are common in patients with osteoporotic vertebral compression fractures(OVCFs) after kyphoplasty.This finite element study was to examine whether short segment pedicle screw fixation(PSF) with kyphoplasty may decrease the fracture risk of the treated and adjacent non-treated vertebrae after kyphoplasty for OVCFs.By simulating cement augmentation with or without short segment pedicle screw fixation(PSF),two tridimensional,anatomically detailed finite element models of the T10–L2 functional spinal junction were developed.The insertion of pedicle screws into the intact vertebra apparently decreased the stress distribution of the treated vertebra in vertical compression and other load situations.The stress distribution in the bone structures of the intact vertebra adjacent to the intact-screwed vertebra was much less than that in the one adjacent to the treated vertebra.The insertion of pedicle screws into the intact vertebra greatly decreased the maximum displacement of the cortical bones and cancellous bones of the vertebrae.Our results indicated that short segment PSF with kyphoplasty may decrease the fracture risk of the treated and adjacent non-treated vertebrae in the management of OVCFs. 展开更多
关键词 finite element analysis osteoporotic vertebral compression fractures KYPHOPLASTY BIOMECHANICS pedicle screw fixation
下载PDF
Posterior Selective Thoracic Fusion in Adolescent Idiopathic Scoliosis Patients:a Comparison of All Pedicle Screws versus Hybrid Instrumentation 被引量:9
12
作者 Bin Yu Jian-guo Zhang Gui-xing Qiu Yi-peng Wang Yu Zhao Jian-xiong Shen Hong Zhao Xin-yu Yang 《Chinese Medical Sciences Journal》 CAS CSCD 2009年第1期30-35,共6页
Objective To analyze the influence of segmental pedicle screws versus hybrid instrumentation on the correction results in adolescent idiopathic scoliosis patients undergoing posterior selective thoracic fusion. Metho... Objective To analyze the influence of segmental pedicle screws versus hybrid instrumentation on the correction results in adolescent idiopathic scoliosis patients undergoing posterior selective thoracic fusion. Methods By reviewing the medical records and roentgenograms of adolescent idiopathic scoliosis patients who underwent selective thoracic fusion from February 2000 to January 2007 in our hospital, the patients were divided into 2 groups according to different instrumentation fashions: Group A was hook-screw-rod (hybrid) internal fixation type, Group B was screw-rod (all pedicle screws) internal fixation type, and the screws were used in every segment on the concave side of the thoracic curve. The parameters of the scoliosis were measured and the correction results were analyzed. Results Totally, 48 patients (7 males, 41 females) were included, with an average age of 14.4 years old and a mean follow-up time of 12.3 months. Thirty and 18 patients were assigned to group A and group B, respectively. The mean preoperative coronal Cobb angles of the thoracic curve were 48.8° and 47.4°, respectively. After surgery, they were corrected to 13.7° and 6.8°, respectively. At final follow-up, they were 17.0° and 9.5°, with an average correction rate of 64.6% and 79.0%, respectively, and the correction rate of group B was significantly higher than that of group A (P=0.003). The mean preoperative coronal Cobb angles of the lumbar curve were 32.6° and 35.2°, respectively. After surgery, they were corrected to 8.6° and 8.3°, respectively. At final follow-up, they were 10.3° and 11.1°, with an average correction rate of 66.8% and 69.9%, respectively, and the correction rate of group B was significantly higher than that of group A (P=0.003). The correction loss of the thoracic curve and lumbar curve in the 2 groups were 3.1° and 1.8°, 2.4° and 2.4°, respectively. No significant difference was noted (both P〉0.05). The decompensation rate at final follow-up in these 2 groups were 4% (1/25) and 7.1% (1/14) respectively, with no significant difference (P〉0.05). 展开更多
关键词 adolescent idiopathic scoliosis selective thoracic fusion internal fixator pedicle screw DECOMPENSATION
下载PDF
Comparison of Clinical Outcomes of Cortical Bone Trajectory and Traditional Pedicle Screw Fixation in Posterior Lumbar Interbody Fusion 被引量:2
13
作者 Sundar Karki Shaodong Zhang +2 位作者 Xiaohu Wang Arjun Sinkemani Ganesh Kumar Sah 《Open Journal of Orthopedics》 2019年第3期31-47,共17页
Posterior lumbar interbody fusion (PLIF) is a common surgical procedure and widely used in the treatment of lumbar degenerative disc disorders. Traditionally, posterior lumbar interbody fusion is done by using the tra... Posterior lumbar interbody fusion (PLIF) is a common surgical procedure and widely used in the treatment of lumbar degenerative disc disorders. Traditionally, posterior lumbar interbody fusion is done by using the traditional pedicle screw (PS) which offers great advantages, but at the same time it has some disadvantages which include the risk of superior facet joint violation and muscle damage. Recently, an alternative method of screw insertion via cortical bone trajectory (CBT) has been invented which has less invasive process and can be placed without the drawbacks associated with the traditional pedicle screw. However, it has to remain an interest whether CBT will provide similar or greater clinical outcomes compared to PS in PLIF. So the main aim of this review is to compare the clinical outcomes of cortical bone trajectory and traditional pedicle screw fixation in posterior lumbar interbody fusion based on the articles published on this topic. Compared to the traditional pedicle screw fixation, PLIF with CBT has similar clinical outcome based on pain intensity, ODI status and JOA score, as well as similar fusion rate and radiological evaluated complication such as loosening of screw. In addition PLIF with CBT has advantages of less facet joint violation, less blood loss, less intraoperative muscle damage and perioperative pain. On the basis of this study, we can suggest that PLIF with CBT can be considered as a reasonable alternative to PS in PLIF. 展开更多
关键词 Posterior LUMBAR INTERBODY Fusion CORTICAL Bone TRAJECTORY Traditional pedicle SCREW Fixation CORTICAL SCREW pedicle SCREW
下载PDF
Spinal pedicle subtraction osteotomy for fixed sagittal imbalance patients 被引量:1
14
作者 Seung-Jae Hyun Yongjung J Kim Seung-Chul Rhim 《World Journal of Clinical Cases》 SCIE 2013年第8期242-248,共7页
In addressing spinal sagittal imbalance through a posterior approach, the surgeon now may choose from among a variety of osteotomy techniques. Posterior column osteotomies such as the facetectomy or Ponte or Smith-Pet... In addressing spinal sagittal imbalance through a posterior approach, the surgeon now may choose from among a variety of osteotomy techniques. Posterior column osteotomies such as the facetectomy or Ponte or Smith-Petersen osteotomy provide the least correction, but can be used at multiple levels with minimal blood loss and a lower operative risk. Pedicle subtraction osteotomies provide nearly 3 times the per-level correction of Ponte/Smith-Petersen osteotomies; however, they carry increased technical demands, longer operative time, and greater blood loss and associated significant morbidity, including neurological injury. The literature focusing on pedicle subtraction osteotomy for fixed sagittal imbalance patients is reviewed. The longterm overall outcomes, surgical tips to reduce the complications and suggestions for their proper application are also provided. 展开更多
关键词 SAGITTAL imbalance pedicle SUBTRACTION OSTEOTOMY Clinical outcome Proximal JUNCTIONAL KYPHOSIS Complication
下载PDF
Liver injury after intermittent or continuous hepatic pedicle clamping and its protection by reduced glutathione 被引量:2
15
《Hepatobiliary & Pancreatic Diseases International》 SCIE CAS 2004年第2期209-213,共5页
关键词 HEPATIC pedicle CLAMPING HEPATIC ISCHEMIA/REPERFUSION injury reduced GLUTATHIONE PROTECTION
下载PDF
Treatment of Anderson Type II Odontoid Fracture in Elderly Patients by Posterior Pedicle Screw Fixation Combined with Iliac Bone Grafting 被引量:1
16
作者 Dun Liu Yong Wang +1 位作者 Bing Hu Jinjun Li 《International Journal of Clinical Medicine》 2017年第11期572-582,共11页
Objectives: To explore the treatment and related prognosis of elderly patients with Anderson II odontoid fracture with posterior pedicle screw fixation combined with iliac bone grafting. Methods: Retrospective analysi... Objectives: To explore the treatment and related prognosis of elderly patients with Anderson II odontoid fracture with posterior pedicle screw fixation combined with iliac bone grafting. Methods: Retrospective analysis of 17 cases of elderly patients with Anderson II odontoid fracture who underwent posterior pedicle screw fixation combined with iliac bone grafting from January 2013 to December 2016. 17 patients had a history of trauma before surgery, and they all have varying degrees of atlantoaxial instability or subluxation and varying degrees of neck occipital pain and limited mobility. Result: No spinal cord or vertebral artery injury occurred during surgery. Follow-up information is complete. The follow-up period was 6 to 48 months (mean 27.4 ± 12.4 months). Postoperative imaging review prompted a good reduction of cervical spine, stable sequence;no pedicle screw loosening, fracture, iliac bone graft at the location of the situation, odontoid fracture and bone healing at the good, the patient after cervical rotation are limited to varying degrees. Conclusion: Posterior pedicle screw fixation combined with iliac bone grafting in elderly patients with Anderson II odontoid fracture can achieve good stability, and the prognosis is good, but long-term cervical rotation function may be affected to varying degrees. 展开更多
关键词 ANDERSON Type II ODONTOID Fracture CERVICAL POSTERIOR Approach pedicle Screw FIXATION
下载PDF
Preventing and localizing esophagogastric anastomosis leakage by sleeve-wrapping of the pedicled omentum 被引量:1
17
作者 Quan-Xing Liu Xu-Feng Deng +2 位作者 Bing Hou Jia-Xin Min Ji-Gang Dai 《World Journal of Gastroenterology》 SCIE CAS 2014年第43期16282-16286,共5页
AIM: To develop a technique of sleeve-wrapping the pedicled omentum around the esophagogastric anastomosis for preventing and localizing leakage.
关键词 Anastomotic leakage Esophageal cancer ESOPHAGECTOMY ESOPHAGOGASTROSTOMY pedicled omentum
下载PDF
Successful outcomes of unilateral vs bilateral pedicle screw fixation for lumbar interbody fusion:A meta-analysis with evidence grading 被引量:1
18
作者 Lei Sun Ai-Xian Tian +1 位作者 Jian-Xiong Ma Xin-Long Ma 《World Journal of Clinical Cases》 SCIE 2022年第36期13337-13348,共12页
BACKGROUND Whether it’s better to adopt unilateral pedicle screw(UPS)fixation or to use bilateral pedicle screw(BPS)one for lumbar degenerative diseases is still controversially undetermined.AIM To make a comparison ... BACKGROUND Whether it’s better to adopt unilateral pedicle screw(UPS)fixation or to use bilateral pedicle screw(BPS)one for lumbar degenerative diseases is still controversially undetermined.AIM To make a comparison between UPS and BPS fixation as to how they work efficaciously and safely in patients suffering from lumbar degenerative diseases.METHODS We have searched a lot in the databases through 2020 with index terms such as“unilateral pedicle screw fixation”and“bilateral pedicle screw fixation.”Only randomized controlled trials and some prospective cohort studies could be found,yielding 15 studies.The intervention was unilateral pedicle screw fixation;Primarily We’ve got outcomes of complications and fusion rates.Secondarily,we’ve achieved outcomes regarding total blood loss,operative time,as well as length of stay.Softwares were installed and utilized for subgroup analysis,analyzing forest plots,sensitivity,heterogeneity,forest plots,publication bias,and risk of bias.RESULTS Fifteen previous cases of study including 992 participants have been involved in our meta-analysis.UPS had slightly lower effects on fusion rate[relative risk(RR)=0.949,95%CI:0.910 to 0.990,P=0.015],which contributed mostly to this metaanalysis,and similar complication rates(RR=1.140,95%CI:0.792 to 1.640,P=0.481),Δvisual analog scale[standard mean difference(SMD)=0.178,95%CI:-0.021 to 0.378,P=0.080],andΔOswestry disability index(SMD=-0.254,95%CI:-0.820 to 0.329,P=0.402).In contrast,an obvious difference has been observed inΔJapanese Orthopedic Association(JOA)score(SMD=0.305,95%CI:0.046 to 0.563,P=0.021),total blood loss(SMD=-1.586,95%CI:-2.182 to-0.990,P=0.000),operation time(SMD=-2.831,95%CI:-3.753 to-1.909,P=0.000),and length of hospital stay(SMD=-0.614,95%CI:-1.050 to-0.179,P=0.006).CONCLUSION Bilateral fixation is more effective than unilateral fixation regarding fusion rate after lumbar interbody fusion.However,JOA,operation time,total blood loss,as well as length of stay were improved for unilateral fixation. 展开更多
关键词 Unilateral pedicle screw fixation Bilateral pedicle screw fixation META-ANALYSIS Spinal fusion surgery DISCECTOMY Lumbar interbody fusion
下载PDF
Potential contribution of pedicle screw design to loosening rate in patients with degenerative diseases of the lumbar spine:An observational study 被引量:1
19
作者 Andrey Bokov Svetlana Pavlova +2 位作者 Anatoliy Bulkin Alexandr Aleynik Sergey Mlyavykh 《World Journal of Orthopedics》 2021年第5期310-319,共10页
BACKGROUND The majority of published data report the results of biomechanical tests of various design pedicle screw performance.The clinical relevance and relative contribution of screw design to instrumentation stabi... BACKGROUND The majority of published data report the results of biomechanical tests of various design pedicle screw performance.The clinical relevance and relative contribution of screw design to instrumentation stability have been insufficiently studied.AIM To estimate the contribution of screw design to rate of pedicle screw loosening in patients with degenerative diseases of the lumbar spine.METHODS This study is a prospective evaluation of 175 patients with degenerative diseases and instability of the lumbar spine segments.Participants underwent spinal instrumentation employing pedicle screws with posterior only or transforaminal interbody fusion.Follow-up was for 18 mo.Patients with signs of pedicle screw loosening on computed tomography were registered;logistic regression analysis was used to identify the factors that influenced the rate of loosening.RESULTS Parameters included in the analysis were screw geometry,type of thread,external and internal screw diameter and helical pitch,bone density in Hounsfield units,number of levels fused,instrumentation without anterior support,laminectomy,and unilateral and bilateral total facet joint resection.The rate of screw loosening decreased with the increment in outer diameter,decrease in core diameter and helical pitch.The rate of screw loosening correlated positively with the number of fused levels and decreasing bone density.Bilateral facet joint removal significantly favored pedicle screw loosening.The influence of other factors was insignificant.CONCLUSION Screw parameters had a significant impact on the loosening rate along with bone quality characteristics,the number of levels fused and the extensiveness of decompression.The significance of the influence of screw parameters was comparable to those of patient-and surgery-related factors.Pedicle screw loosening was influenced by helical pitch,inner and outer diameter,but screw geometry and thread type were insignificant factors. 展开更多
关键词 Degenerative diseases Lumbar spine pedicle screw design pedicle screw loosening
下载PDF
Investigation of optical reflectance from different animal vertebra along the fixation trajectory of pedicle screw in frequency domain 被引量:1
20
作者 Yangyang Liu Huan Zhang +2 位作者 Ying Tong Zhiyu Qian Weitao Li 《Journal of Innovative Optical Health Sciences》 SCIE EI CAS 2020年第1期132-141,共10页
Accurate placement of pedicle screw(PS)is crucial in spinal surgery.Developing new real-time intra-operative monitoring and navigation methods is an important direction of clinical appli-cation research.In this paper,... Accurate placement of pedicle screw(PS)is crucial in spinal surgery.Developing new real-time intra-operative monitoring and navigation methods is an important direction of clinical appli-cation research.In this paper,we studied the spectrum along the fixation trajectory of PS in frequency domain to tackle the accuracy problem.Fresh porcine vertebrae,bovine vertebrae and ovine vertebrae were measured with the near-infrared spectrum(NIR)device to obtain the reflected spectrum from the vertebrae.Along the fixation trajectory of PS,average energy from different groups was calculated and used for identifying different tissues and compared to achieve the optimal recognition factor.Compared with the time domain approach,the frequency domain method could divide the spectra measured at different tissue points into different groups more stably and accurately,which could serve as a new method to assist the PS insertion.The results gained from this study are significant to the development of hi-tech medical instruments with independent intellectual property rights. 展开更多
关键词 pedicle screw fixation frequency domain optical reflectance VERTEBRA
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部