Total mesorectal excision(TME)is the standard surgical treatment for the curative radical resection of rectal cancers.Minimally invasive TME has been gaining ground favored by the continuous technological advancements...Total mesorectal excision(TME)is the standard surgical treatment for the curative radical resection of rectal cancers.Minimally invasive TME has been gaining ground favored by the continuous technological advancements.New procedures,such as transanal TME(TaTME),have been introduced to overcome some technical limitations,especially in low rectal tumors,obese patients,and/or narrow pelvis.The earliest TaTME reports showed promising results when compared with the conventional laparoscopic TME.However,recent publications raised concerns regarding the high rates of anastomotic leaks or local recurrences observed in national series.Robotic TaTME(R-TaTME)has been proposed as a novel technique incorporating the potential benefits of a perineal dissection together with precise control of the distal margins,and also offers all those advantages provided by the robotic technology in terms of improved precision and dexterity.Encouraging short-term results have been reported for R-TaTME,but further studies are needed to assess the real role of the new technique in the long-term oncological or functional outcomes.The present review aims to provide a general overview of R-TaTME by analyzing the body of the available literature,with a special focus on the potential benefits,harms,and future perspectives for this novel approach.展开更多
AIM To assess the efficacy of a modified approach with transanal total mesorectal excision(ta TME) using simple customized instruments in male patients with low rectal cancer.METHODS A total of 115 male patients with ...AIM To assess the efficacy of a modified approach with transanal total mesorectal excision(ta TME) using simple customized instruments in male patients with low rectal cancer.METHODS A total of 115 male patients with low rectal cancer from December 2006 to August 2015 were retrospectively studied. All patients had a bulky tumor(tumor diameter ≥ 40 mm). Forty-one patients(group A) underwent a classical approach of transabdominal total mesorectal excision(TME) and transanal intersphincteric resection(ISR), and the other 74 patients(group B) underwent a modified approach with transabdominal TME,transanal ISR, and ta TME. Some simple instruments including modified retractors and an anal dilator with a papilionaceous fixture were used to perform ta TME. The operative time, quality of mesorectal excision, circumferential resection margin, local recurrence, and postoperative survival were evaluated.RESULTS All 115 patients had successful sphincter preservation. The operative time in group B(240 min, range: 160-330 min) was significantly shorter than that in group A(280 min, range: 200-360 min; P = 0.000). Co m pa r e d w it h g r o up A, m o r e c o m p le t e d is t a l mesorectum and total mesorectum were achieved in group B(100% vs 75.6%, P = 0.000; 90.5% vs 70.7%, P = 0.008, respectively). After 46.1 ± 25.6 mo followup, group B had a lower local recurrence rate and higher disease-free survival rate compared with group A, but these differences were not statistically significant(5.4% vs 14.6%, P = 0.093; 79.5% vs 65.1%, P = 0.130). CONCLUSION Retrograde ta TME with simple customized instruments can achieve high-quality TME, and it might be an effective and economical alternative for male patients with bulky tumors.展开更多
Background: Stapled transanal rectal resection (STARR) has been shown to improve patients’ functional and quality of life outcomes in several studies. Although it is a safe and effective treatment for obstructive def...Background: Stapled transanal rectal resection (STARR) has been shown to improve patients’ functional and quality of life outcomes in several studies. Although it is a safe and effective treatment for obstructive defecation syndrome, still data on long-term follow-up are missing. Methods: From January 2010 to July 2014, 46 consecutive patients undergoing STARR using the CONTOUR® TRANSTAR™ device, shortly named TRANSTAR (transanal stapler assisted resection), were prospectively followed. Recurrence rate, quality of life (Patient Assessment of Constipation-Quality of Life (PAC-Qol)) and complication were documented at baseline, 12 and 24 months after operation. Two subgroups of patients were compared to assess the impact of resection length on outcome. Results: We included 46 patients (89% female) in the study. The mean age was 65 ± 16 years and the duration of the operation was 48 ± 4 min. Total PAC-QoL score improved from 2.0 (SD 0.3) to 0.9 (1.4) after 12 months, but deteriorated to 1.2 (0.3) after 24 months (p < 0.001 for both comparisons). Complications were noted in 7% of the patients: Urinary retention (2 patients), postoperative bleeding (1 patient). No major complications or mortality were seen. After one year, we had one prolapse recurrence and after 24 month we had another. There was no significant relation between the length of the specimen and the improvement of life quality. Conclusions: The STARR procedure seems to be a safe and fast therapeutic option for patients with ODS and/or rectal prolapse. It is a tailored transanal full-thickness rectal resection improving the patients’ quality of life still two years after the operation.展开更多
文摘Total mesorectal excision(TME)is the standard surgical treatment for the curative radical resection of rectal cancers.Minimally invasive TME has been gaining ground favored by the continuous technological advancements.New procedures,such as transanal TME(TaTME),have been introduced to overcome some technical limitations,especially in low rectal tumors,obese patients,and/or narrow pelvis.The earliest TaTME reports showed promising results when compared with the conventional laparoscopic TME.However,recent publications raised concerns regarding the high rates of anastomotic leaks or local recurrences observed in national series.Robotic TaTME(R-TaTME)has been proposed as a novel technique incorporating the potential benefits of a perineal dissection together with precise control of the distal margins,and also offers all those advantages provided by the robotic technology in terms of improved precision and dexterity.Encouraging short-term results have been reported for R-TaTME,but further studies are needed to assess the real role of the new technique in the long-term oncological or functional outcomes.The present review aims to provide a general overview of R-TaTME by analyzing the body of the available literature,with a special focus on the potential benefits,harms,and future perspectives for this novel approach.
基金Supported by(in part)Wenzhou Science and Technology Project,No.Y20160044Suzhou Key Medical Center,No.LCZX201505+2 种基金Soochow Development of Science and Technology Projects,No.SZS201618Chinese Natural Science Foundation,No.81672970Second Affiliated Hospital of Soochow University Preponderant Clinic Discipline Group Project,No.XKQ2015007
文摘AIM To assess the efficacy of a modified approach with transanal total mesorectal excision(ta TME) using simple customized instruments in male patients with low rectal cancer.METHODS A total of 115 male patients with low rectal cancer from December 2006 to August 2015 were retrospectively studied. All patients had a bulky tumor(tumor diameter ≥ 40 mm). Forty-one patients(group A) underwent a classical approach of transabdominal total mesorectal excision(TME) and transanal intersphincteric resection(ISR), and the other 74 patients(group B) underwent a modified approach with transabdominal TME,transanal ISR, and ta TME. Some simple instruments including modified retractors and an anal dilator with a papilionaceous fixture were used to perform ta TME. The operative time, quality of mesorectal excision, circumferential resection margin, local recurrence, and postoperative survival were evaluated.RESULTS All 115 patients had successful sphincter preservation. The operative time in group B(240 min, range: 160-330 min) was significantly shorter than that in group A(280 min, range: 200-360 min; P = 0.000). Co m pa r e d w it h g r o up A, m o r e c o m p le t e d is t a l mesorectum and total mesorectum were achieved in group B(100% vs 75.6%, P = 0.000; 90.5% vs 70.7%, P = 0.008, respectively). After 46.1 ± 25.6 mo followup, group B had a lower local recurrence rate and higher disease-free survival rate compared with group A, but these differences were not statistically significant(5.4% vs 14.6%, P = 0.093; 79.5% vs 65.1%, P = 0.130). CONCLUSION Retrograde ta TME with simple customized instruments can achieve high-quality TME, and it might be an effective and economical alternative for male patients with bulky tumors.
文摘Background: Stapled transanal rectal resection (STARR) has been shown to improve patients’ functional and quality of life outcomes in several studies. Although it is a safe and effective treatment for obstructive defecation syndrome, still data on long-term follow-up are missing. Methods: From January 2010 to July 2014, 46 consecutive patients undergoing STARR using the CONTOUR® TRANSTAR™ device, shortly named TRANSTAR (transanal stapler assisted resection), were prospectively followed. Recurrence rate, quality of life (Patient Assessment of Constipation-Quality of Life (PAC-Qol)) and complication were documented at baseline, 12 and 24 months after operation. Two subgroups of patients were compared to assess the impact of resection length on outcome. Results: We included 46 patients (89% female) in the study. The mean age was 65 ± 16 years and the duration of the operation was 48 ± 4 min. Total PAC-QoL score improved from 2.0 (SD 0.3) to 0.9 (1.4) after 12 months, but deteriorated to 1.2 (0.3) after 24 months (p < 0.001 for both comparisons). Complications were noted in 7% of the patients: Urinary retention (2 patients), postoperative bleeding (1 patient). No major complications or mortality were seen. After one year, we had one prolapse recurrence and after 24 month we had another. There was no significant relation between the length of the specimen and the improvement of life quality. Conclusions: The STARR procedure seems to be a safe and fast therapeutic option for patients with ODS and/or rectal prolapse. It is a tailored transanal full-thickness rectal resection improving the patients’ quality of life still two years after the operation.