期刊文献+
共找到41篇文章
< 1 2 3 >
每页显示 20 50 100
Rates, predictors, and causes of readmission after transcatheter aortic valve replacement in patients with chronic kidney disease
1
作者 Taha Teaima Gianfranco Bittar Carlini +5 位作者 Rohan A Gajjar Imran Aziz Sami J Shoura Abdul-Rahim Shilbayeh Naim Battikh Tareq Alyousef 《World Journal of Cardiology》 2024年第7期402-411,共10页
BACKGROUND Transcatheter aortic valve replacement(TAVR)is a revolutionary procedure for severe aortic stenosis.The coexistence of chronic kidney disease(CKD)and TAVR introduces a challenge that significantly impacts p... BACKGROUND Transcatheter aortic valve replacement(TAVR)is a revolutionary procedure for severe aortic stenosis.The coexistence of chronic kidney disease(CKD)and TAVR introduces a challenge that significantly impacts patient outcomes.AIM To define readmission rates,predictors,and causes after TAVR procedure in CKD stage 1-4 patients.METHODS We used the national readmission database 2018 and 2020 to look into readmission rates,causes and predictors after TAVR procedure in patients with CKD stage 1-4.RESULTS Out of 24758 who underwent TAVR and had CKD,7892(32.4%)patients were readmitted within 90 days,and had higher adjusted odds of being females(adjusted odds ratio:1.17,95%CI:1.02-1.31,P=0.02)with longer length of hospital stay>6 days,and more comorbidities including but not limited to diabetes mellitus,anemia,and congestive heart failure(CHF).CONCLUSION Most common causes of readmission included CHF(18.0%),sepsis,and complete atrioventricular block.Controlling readmission predictors with very close followup is warranted to prevent such high rate of readmission. 展开更多
关键词 Chronic kidney disease transcatheter aortic valve replacement READMISSION PREDICTORS Rates
下载PDF
Risk of permanent pacemaker implantation following transcatheter aortic valve replacement:Which factors are most relevant?
2
作者 Akash Batta Juniali Hatwal 《World Journal of Cardiology》 2024年第2期49-53,共5页
Transcatheter aortic valve replacement(TAVR)has emerged as a formidable treatment option for severe symptomatic aortic stenosis ahead of surgical aortic valve replacement.The encouraging results from large randomized ... Transcatheter aortic valve replacement(TAVR)has emerged as a formidable treatment option for severe symptomatic aortic stenosis ahead of surgical aortic valve replacement.The encouraging results from large randomized controlled trials has resulted in an exponential rise in the use of TAVR even in the low-risk patients.However,this is not without challenges.Need for permanent pacemaker(PPM)post-TAVR remains the most frequent and clinically relevant challenge.Naturally,identifying risk factors which predispose an individual to develop high grade conduction block post-TAVR is important.Various demographic factors,electrocardiographic features,anatomic factors and procedural characteristics have all been linked to the development of advanced conduction block and need for PPM following TAVR.Amongst these electrophysiological variables,most notably a prolonged QRS>120 ms regardless of the type of conduction block seems to be one of the strongest predictors on logistic regression models.The index study by Nwaedozie et al highlights that patients requiring PPM post-TAVR had higher odds of having a baseline QRS>120 ms and were more likely to be having diabetes mellitus that those who did not require PPM. 展开更多
关键词 transcatheter aortic valve replacement Permanent pacemaker Diabetes mellitus QRS duration Electrophysiological variables
下载PDF
Current knowledge for the risk factors of early permanent pacemaker implantation following transcatheter aortic valve replacement and what is next for the primary prevention?
3
作者 Gen-Min Lin Wei-Chun Huang Chih-Lu Han 《World Journal of Cardiology》 2024年第2期54-57,共4页
In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from... In this editorial,we comprehensively summarized the preoperative risk factors of early permanent pacemaker implantation after transcatheter aortic valve replacement(TAVR)among patients with severe aortic stenosis from several renowned clinical studies and focused on the primary prevention of managing the modifiable factors,e.g.,paroxysmal atrial fibrillation before the TAVR. 展开更多
关键词 Permanent pacemaker implantation transcatheter aortic valve replacement Interventricular conduction delay DIABETES Supraventricular arrhythmia
下载PDF
Transcatheter aortic valve replacement in low-risk young population:A double edge sword?
4
作者 Sukhdeep Bhogal Akash Batta 《World Journal of Cardiology》 2024年第4期177-180,共4页
Since the advent of transcatheter aortic valve replacement(TAVR)in 2002,it has now become the default interventional strategy for symptomatic patients presenting with severe aortic stenosis,particularly in intermediat... Since the advent of transcatheter aortic valve replacement(TAVR)in 2002,it has now become the default interventional strategy for symptomatic patients presenting with severe aortic stenosis,particularly in intermediate to highsurgical risk patients.In 2019,the United States Food and Drug Administration approved TAVR in low-risk patients based on two randomized trials.However,these breakthrough trials excluded patients with certain unfavorable anatomies and odd profiles.While currently there is no randomized study of TAVR in young patients,it may be preferred by the young population given the benefits of early discharge,shorter hospital stay,and expedite recovery.Nonetheless,it is important to ruminate various factors including lifetime expectancy,risk of pacemaker implantation,and the need for future valve or coronary interventions in young cohorts before considering TAVR in these patients.Furthermore,the data on long-term durability(>10 years)of TAVR is still unknown given most of the procedures were initially performed in the high or prohibitive surgical risk population.Thus,this editorial aims to highlight the importance of considering an individualized approach in young patients with consideration of various factors including lifetime expectancy while choosing TAVR against surgical aortic valve replacement. 展开更多
关键词 transcatheter aortic valve replacement Surgical aortic valve replacement Pacemaker implantation Coronary re-access Structural deterioration
下载PDF
Pacemaker post transcatheter aortic valve replacement:A multifactorial risk?
5
作者 Stephane Noble Karim Bendjelid 《World Journal of Cardiology》 2024年第4期168-172,共5页
Pacemaker post-transcatheter aortic valve replacement is related to multifactorial risk.Nwaedozie et al brought to the body of evidence electrocardiogram and clinical findings.However,procedural characteristics have a... Pacemaker post-transcatheter aortic valve replacement is related to multifactorial risk.Nwaedozie et al brought to the body of evidence electrocardiogram and clinical findings.However,procedural characteristics have at least as much impact on the final need for a permanent pacemaker and potentially on the pacing rate.In this regard,long-term follow-up and understanding of the impact of long-term stimulation is of utmost importance. 展开更多
关键词 transcatheter aortic valve replacement Permanent pacemaker implantation Conduction abnormalities Right bundle branch block Left bundle branch block
下载PDF
Novel predictors of permanent pacemaker implantation following transcatheter aortic valve replacement 被引量:4
6
作者 Somto Nwaedozie Haibin Zhang +7 位作者 Javad Najjar Mojarrab Param Sharma Paul Yeung Peter Umukoro Deepa Soodi Rachel Gabor Kelley Anderson Romel Garcia-Montilla 《World Journal of Cardiology》 2023年第11期582-598,共17页
BACKGROUND Conduction and rhythm abnormalities requiring permanent pacemakers(PPM)are short-term complications following transcatheter aortic valve replacement(TAVR),and their clinical outcomes remain conflicting.Pote... BACKGROUND Conduction and rhythm abnormalities requiring permanent pacemakers(PPM)are short-term complications following transcatheter aortic valve replacement(TAVR),and their clinical outcomes remain conflicting.Potential novel predictors of post-TAVR PPM,like QRS duration,QTc prolongation,and supraventricular arrhythmias,have been poorly studied.AIM To evaluate the effects of baseline nonspecific interventricular conduction delay and supraventricular arrhythmia on post-TAVR PPM requirement and determine the impact of PPM implantation on clinical outcomes.METHODS RESULTS Out of the 357 patients that met inclusion criteria,the mean age was 80 years,188(52.7%)were male,and 57(16%)had a PPM implantation.Baseline demographics,valve type,and cardiovascular risk factors were similar except for type II diabetes mellitus(DM),which was more prevalent in the PPM cohort(59.6%vs 40.7%;P=0.009).The PPM cohort had a significantly higher rate of pre-procedure right bundle branch block,prolonged QRS>120 ms,prolonged QTc>470 ms,and supraventricular arrhythmias.There was a consistently significant increase in the odds ratio(OR)of PPM implantation for every 20 ms increase in the QRS duration above 100 ms:QRS 101-120[OR:2.44;confidence intervals(CI):1.14-5.25;P=0.022],QRS 121-140(OR:3.25;CI:1.32-7.98;P=0.010),QRS 141-160(OR:6.98;CI:3.10-15.61;P<0.001).After model adjustment for baseline risk factors,the OR remained significant for type II DM(aOR:2.16;CI:1.18-3.94;P=0.012),QRS>120(aOR:2.18;CI:1.02-4.66;P=0.045)and marginally significant for supraventricular arrhythmias(aOR:1.82;CI:0.97-3.42;P=0.062).The PPM cohort had a higher adjusted OR of heart failure(HF)hospitalization(aOR:2.2;CI:1.1-4.3;P=0.022)and nonfatal myocardial infarction(MI)(aOR:3.9;CI:1.1-14;P=0.031)without any difference in mortality(aOR:1.1;CI:0.5-2.7;P=0.796)at one year.CONCLUSION Pre-TAVR type II DM and QRS duration>120,regardless of the presence of bundle branch blocks,are predictors of post-TAVR PPM.At 1-year post-TAVR,patients with PPM have higher odds of HF hospitalization and MI. 展开更多
关键词 transcatheter aortic valve replacement Balloon-expandable valve Self-expandable valve Myocardial infarction Left bundle-branch block Nonspecific inter-ventricular defect Coronary artery bypass graft Coronary artery disease
下载PDF
Prediction of permanent pacemaker implantation after transcatheter aortic valve replacement:The role of machine learning 被引量:1
7
作者 Pradyumna Agasthi Hasan Ashraf +16 位作者 Sai Harika Pujari Marlene Girardo Andrew Tseng Farouk Mookadam Nithin Venepally Matthew R Buras Bishoy Abraham Banveet K Khetarpal Mohamed Allam Siva K Mulpuru MD Mackram F Eleid Kevin L Greason Nirat Beohar John Sweeney David Fortuin David R Jr Holmes Reza Arsanjani 《World Journal of Cardiology》 2023年第3期95-105,共11页
BACKGROUND Atrioventricular block requiring permanent pacemaker(PPM)implantation is an important complication of transcatheter aortic valve replacement(TAVR).Application of machine learning could potentially be used t... BACKGROUND Atrioventricular block requiring permanent pacemaker(PPM)implantation is an important complication of transcatheter aortic valve replacement(TAVR).Application of machine learning could potentially be used to predict preprocedural risk for PPM.AIM To apply machine learning to be used to predict pre-procedural risk for PPM.METHODS A retrospective study of 1200 patients who underwent TAVR(January 2014-December 2017)was performed.964 patients without prior PPM were included for a 30-d analysis and 657 patients without PPM requirement through 30 d were included for a 1-year analysis.After the exclusion of variables with near-zero variance or≥50%missing data,167 variables were included in the random forest gradient boosting algorithm(GBM)optimized using 5-fold cross-validations repeated 10 times.The receiver operator curve(ROC)for the GBM model and PPM risk score models were calculated to predict the risk of PPM at 30 d and 1 year.RESULTS Of 964 patients included in the 30-d analysis without prior PPM,19.6%required PPM post-TAVR.The mean age of patients was 80.9±8.7 years.42.1%were female.Of 657 patients included in the 1-year analysis,the mean age of the patients was 80.7±8.2.Of those,42.6%of patients were female and 26.7%required PPM at 1-year post-TAVR.The area under ROC to predict 30-d and 1-year risk of PPM for the GBM model(0.66 and 0.72)was superior to that of the PPM risk score(0.55 and 0.54)with a P value<0.001.CONCLUSION The GBM model has good discrimination and calibration in identifying patients at high risk of PPM post-TAVR. 展开更多
关键词 transcatheter aortic valve replacement Permanent pacemaker implantation Machine learning
下载PDF
Transcatheter aortic valve replacement and stroke: a comprehensive review 被引量:7
8
作者 Periklis A Davlouros Virginia C Mplani +2 位作者 Ioanna Koniari Grigorios Tsigkas George Hahalis 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2018年第1期95-104,共10页
Transcatheter aortic valve implantation (TAVR) has emerged as an alternative, rapidly evolving treatment option for patients with se- vere aortic stenosis and high surgical risk. Stroke is a devastating complication... Transcatheter aortic valve implantation (TAVR) has emerged as an alternative, rapidly evolving treatment option for patients with se- vere aortic stenosis and high surgical risk. Stroke is a devastating complication being confined mainly in the periprocedural and 30-day pe- riod following TAVR, with a lower and relatively constant frequency thereafter. Early stroke is mainly due to debris embolization during the procedure, whereas later events are associated with patient specific factors. Despite the fact that the rate of clinical stroke has been constantly decreasing compared to initial TAVR experience, modern neuro-imaging with MRI suggests that new ischemic lesions post-TAVR are almost universal. The impact of the latter is largely unknown. However, they seem to correlate with a reduction in neurocognitive function. Because TAVR is set to expand its indication to lower surgical-risk patients, stroke prophylaxis during and after TAVR becomes of paramount importance. Based on clinical and pathophysiological evidence, three lines of research are actively employed towards this direction: improvement in valve and delivery system technology with an aim to reduce manipulations and contact with the calcified aortic arch and native valve, antithrombotic therapy, and embolic protection devices. Careful patient selection, design of the procedure, and tailored antithrombotic strategies respecting the bleeding risks of this fragile population constitute the main defense against stroke following TAVR. 展开更多
关键词 aortic stenosis STROKE transcatheter aortic valve replacement
下载PDF
Transcatheter aortic valve replacement in elderly patients 被引量:2
9
作者 Dimytri Siqueira Alexandre Abizaid +1 位作者 Magaly Arrais J. Eduardo Sousa 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2012年第2期78-82,共5页
Aortic stenosis is the most common native valve disease, affecting up to 5% of the elderly population. Surgical aortic valve replacement reduces symptoms and improves survival, and is the definitive therapy in patient... Aortic stenosis is the most common native valve disease, affecting up to 5% of the elderly population. Surgical aortic valve replacement reduces symptoms and improves survival, and is the definitive therapy in patients with symptomatic severe aortic stenosis. However, despite the good results of classic surgery, risk is markedly increased in elderly patients with co-morbidities. Transcatheter aortic valve replacement (TAVR) allows implantation of a prosthetic heart valve within the diseased native aortic valve without the need for open heart surgery and cardiopulmonary bypass, offering a new therapeutic option to elderly patients considered at high surgical risk or with contraindications to surgery. To date, several multicenter registries and a randomized trial have confirmed the safety and efficacy of TAVR in those patients. In this chapter, we review the background and clinical applications of TAVR in elderly patients. 展开更多
关键词 aortic stenosis Elderly patients transcatheter aortic valve replacement Percutaneous valve therapies
下载PDF
Comparison of in-hospital outcomes between octogenarians and nonagenarians undergoing transcatheter aortic valve replacement: a propensity matched analysis 被引量:2
10
作者 Rajkumar Doshi Vaibhav Patel Priyank Shah 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2018年第2期123-130,共8页
Background Aortic valve stenosis (AS) is very common in the elderly patients above 80 years. Transcatheter aortic valve replacement (TAVR) in such patients is being increasingly performed. This study sought to ass... Background Aortic valve stenosis (AS) is very common in the elderly patients above 80 years. Transcatheter aortic valve replacement (TAVR) in such patients is being increasingly performed. This study sought to assess in-hospital outcome differences between octogenarians and nonagenarians and predictors of mortality in nonagenarians undergoing TAVR with severe AS. Method The study population was derived from the National Inpatient Sample (MS) for the years 2012-2014 using ICD-9 CM procedure codes 35.05 and 35.06 for TAVR. Hospitalizations below 80 years of age were excluded. After performing propensity score matching (1: 2), in-hospital outcomes were compared in matched cohorts. Then, multivariate model was developed to analyze predictors of in-hospital mortality in nonagenarians. Results There were 11,630 hospitalizations in the octogenarian and 5815 hospitalizations in the nonagenarian group. Primary outcome of in-hospital mortality (6% vs. 4.1%, P ≤ 0.001) was higher in nonagenarians compared to octogenarians. Secondary outcomes including stroke (3.4% vs. 2.8%, P ≤ 0.001), renal failure (18.9% vs. 17.3%, P ≤0.001), blood transfusion (35% vs. 32.6%, P ≤ 0.001), vascular complications (4.5% vs. 3.5%, P ≤ 0.001), and pacemaker implantation (27.8% vs. 24.8%, P ≤ 0.001) were higher in nonagenarians. There was no difference in their length of stay. Median cost (70,3745 vs. 65,3815, P ≤ 0.001) was slightly higher with nonagenarian. Conclusions Although in-hospital mortality is slightly higher in nonagenarians, it is acceptable. This difference in mortality is at least partly explained by higher complications in nonagenarians. Efforts should be made to decrease the complications which can further narrow the difference in in-hospital mortality between the groups. 展开更多
关键词 NONAGENARIAN OCTOGENARIAN Quality of Life transcatheter aortic valve replacement
下载PDF
Effect of transcatheter aortic valve replacement on P-wave duration, P-wave dispersion and left atrial size 被引量:2
11
作者 Huseyin Dursun Zulkif Tanriverdi +1 位作者 Tugce Colluoglu Dayimi Kaya 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2015年第6期613-617,共5页
Background P-wave dispersion (PWD), a measure of heterogeneity of atrial refractoriness, is defined as the difference between the maximum and minimum P-wave duration. In patients with severe aortic stenosis (AS), ... Background P-wave dispersion (PWD), a measure of heterogeneity of atrial refractoriness, is defined as the difference between the maximum and minimum P-wave duration. In patients with severe aortic stenosis (AS), P-wave duration and PWD were shown to be increased, indicating atrial electrical remodeling. However, the effect of transcatheter aortic valve replacement (TAVR) on P-wave morphology has not been established yet. The aim of this study is to assess the short and long-term effects of TAVR with two types of bioprosthetic valves on P-wave duration and PWD in association with left atrial (LA) size. Methods Fifty-two (36 female) eligible patients in sinus rhythm who underwent transfemoral TAVR between June 01, 2012 and July 31, 2014 with either a Medtronic CoreValve (MCV) (n = 32) or an Edwards SAPIEN XT Valve (n = 20) were enrolled. Standard 12-lead electrocardiogram and echocardiographic evaluations were per- formed pre-procedurally, post-TAVR day one and 6 months post-TAVR. P-wave duration and PWD were measured and correlation analyses with echocardiographic variables were performed. Results P-wave duration and PWD were significantly decreased on post-TAVR day one (P 〈 0.05). They continued to decrease during the six month follow-up period, but were not significantly different from short-term values (P 〉 0.05). The decrease of LA diameter was found significant at the sixth-months of follow-up (P 〈 0.05). These changes were independent from the types of bioprosthetic valves implanted (P 〉 0.05). A positive correlation was detected between minimum P-wave duration and maximum aortic valve gradients at post-TAVR day one (r = 0.297, P = 0.032). Conclusions P-wave duration and PWD were significantly reduced early after TAVR indicating early reverse atrial electrical remodeling. Moreover, structural reverse remodeling of atrium was detected at the 6-months of follow-up. The effects of two types of bioprosthetic valves on atrial remodeling were similar. 展开更多
关键词 aortic stenosis P-wave dispersion transcatheter aortic valve replacement
下载PDF
Early mortality and safety after transcatheter aortic valve replacement using the SAPIEN 3 in nonagenarians 被引量:2
12
作者 Eiji Ichimoto Adam Arnofsky +2 位作者 Michael Wilderman Richard Goldweit Joseph De Gregorio 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2018年第6期387-393,共7页
Background Transcatheter aortic valve replacement (TAVR) has been performed for many elderly patients with severe aortic stenosis (AS). The SAPIEN 3 is one of the latest balloon-expandable prosthesis. This study a... Background Transcatheter aortic valve replacement (TAVR) has been performed for many elderly patients with severe aortic stenosis (AS). The SAPIEN 3 is one of the latest balloon-expandable prosthesis. This study aimed to investigate the early clinical outcomes after TAVR using the SAPIEN 3 in nonagenarians. Methods A total of 97 consecutive patients underwent TAVR for severe AS between De- cember 2015 and December 2016. Of these, 85 consecutive patients who underwent TAVR using the SAPIEN 3 were included. According to the age, patients were classified into age 〉 90 years group (17 patients) or age 〈 90 years group (68 patients). The clinical outcomes in- cluding all-cause mortality and composite endpoint of early safety at 30 days were evaluated. Results The Society of Thoracic Surgeons score in age 〉 90 years group was higher than age 〈 90 years group (12.3 ±6.1% vs. 8.5 ± 5.1%, P 〈 0.01). There was no significant difference in 30-day mortality between the two groups. However, the life-threatening bleeding and major vascular complications in age 〉 90 years group were greater than age 〈 90 years group (11.8% vs. 1.5%, P = 0.04 and 11.8% vs. 1.5%, P = 0.04, respectively). The composite endpoint of early safety at 30 days was similar between the two groups. Multivariate logistic regression analysis showed that prior myocardial infarction was an independent predictor of the composite endpoint of early safety (odds ratio: 4.76, 95% confidence interval: 1.02-22.21, P = 0.047). Conclusions The early mortality and safety after TAVR using the SAPIEN 3 in nonagenarians were similar and acceptable despite of higher operative risk. 展开更多
关键词 NONAGENARIANS SAPIEN 3 transcatheter aortic valve replacement
下载PDF
Patient selection for transcatheter aortic valve replacement:A combined clinical and multimodality imaging approach 被引量:1
13
作者 Rosangela Cocchia Antonello D’Andrea +9 位作者 Marianna Conte Massimo Cavallaro Lucia Riegler Rodolfo Citro Cesare Sirignano Massimo Imbriaco Maurizio Cappelli Giovanni Gregorio Raffaele Calabrò Eduardo Bossone 《World Journal of Cardiology》 CAS 2017年第3期212-229,共18页
Transcatheter aortic valve replacement(TAVR) has been validated as a new therapy for patients affected by severe symptomatic aortic stenosis who are not eligible for surgical intervention because of major contraindica... Transcatheter aortic valve replacement(TAVR) has been validated as a new therapy for patients affected by severe symptomatic aortic stenosis who are not eligible for surgical intervention because of major contraindication or high operative risk. Patient selection for TAVR should be based not only on accurate assessment of aortic stenosis morphology, but also on several clinical and functional data. Multi-Imaging modalities should be preferred for assessing the anatomy and the dimensions of the aortic valve and annulus before TAVR. Ultrasounds represent the first line tool in evaluation of this patients giving detailed anatomic description of aortic valve complex and allowing estimating with enough reliability the hemodynamic entity of valvular stenosis. Angiography should be used to assess coronary involvement and plan a revascularization strategy before the implant. Multislice computed tomography play a central role as it can give anatomical details in order to choice the best fitting prosthesis, evaluate the morphology of the access path and detect other relevant comorbidities. Cardiovascular magnetic resonance and positron emission tomography are emergent modality helpful in aortic stenosis evaluation. The aim of this review is to give an overview onTAVR clinical and technical aspects essential for adequate selection. 展开更多
关键词 aortic stenosis Doppler echocardiography Cardiac computed tomography Two-dimensional strain Three dimensional echocardiography Cardiac magnetic resonance transcatheter aortic valve replacement
下载PDF
Anemia and risk of periprocedural cerebral injury detected by diffusion-weighted magnetic resonance imaging in patients undergoing transcatheter aortic valve replacement 被引量:1
14
作者 Stella Ng Qi-feng Zhu +5 位作者 Ju-bo Jiang Chun-hui Liu Jia-qi Fan Ye-ming Xu Xian-bao Liu Jian-an Wang 《World Journal of Emergency Medicine》 SCIE CAS CSCD 2022年第1期32-39,共8页
BACKGROUND: Anemia is prevalent in patients undergoing transcatheter aortic valve replacement(TAVR) and has been linked to impaired outcomes after the procedure. Few studies have evaluated the impact of anemia and new... BACKGROUND: Anemia is prevalent in patients undergoing transcatheter aortic valve replacement(TAVR) and has been linked to impaired outcomes after the procedure. Few studies have evaluated the impact of anemia and new ischemic lesions post TAVR.METHODS: We prospectively enrolled 158 patients who received TAVR in our center. Anemia was defined according to the World Health Organization criteria as hemoglobin <12 g/dL in women and <13 g/dL in men. All patients underwent diffusion-weighted magnetic resonance imaging(DW-MRI) procedure before and within 4–7 days after TAVR. RESULTS: Anemia was present in 85(53.8%) patients who underwent TAVR, and 126(79.7%) patients had 718 new DW-MRI positive lesions with a mean of 4.54±5.26 lesions per patient. The incidence of new ischemic lesions was 81.2% in patients with anemia versus 78.1% in patients without anemia(P=0.629). Moreover, anemic patients had bigger total volume/lesions in the anterior cerebral artery/middle cerebral artery(ACA/MCA) and MCA regions compared to the non-anemic patients(31.89±55.78 mm^(3) vs. 17.08±37.39 mm^(3), P=0.049;and 54.54±74.72 mm^(3) vs. 33.75±46.03 mm^(3), P=0.034). Anemia was independently associated with the volume/lesion in the ACA/MCA(β=16.796, 95% confidence interval [95% CI] 2.001 to 31.591, P=0.026) and in the MCA zone(β=0.020, 95% CI 0.001 to 0.040, P=0.041). CONCLUSIONS: Patients with pre-procedural anemia may have bigger total volume/lesions in the ACA/MCA and MCA regions compared to the non-anemic patients. Whether the consequences of bigger total volume/lesions impact neurological and cognitive outcomes remains to be investigated. 展开更多
关键词 aortic stenosis ANEMIA Cerebral ischemic lesions transcatheter aortic valve replacement
下载PDF
Measuring frailty in patients with severe aortic stenosis:a comparison of the edmonton frail scale with modified fried frailty assessment in patients undergoing transcatheter aortic valve replacement 被引量:1
15
作者 Francisco J Romeo Maximiliano Smietniansky +8 位作者 Mariela Cal Cristian Garmendia Juan M Valle Raleigh Ignacio MSeropian Mariano Falconi Pablo Oberti Vadim Kotowicz Carla RAgatiello Daniel H Berroca 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2020年第7期441-446,共6页
Frailty is generally defined as a clinical syndrome of decreased physiologic reserve which drives to increased vulnerability and susceptibility to different stressors together with poor recovery to homeostasis.[1]The ... Frailty is generally defined as a clinical syndrome of decreased physiologic reserve which drives to increased vulnerability and susceptibility to different stressors together with poor recovery to homeostasis.[1]The relevance of frailty status in a wide range of prospective cohorts is mostly related to an increasing burden in both mortality,hospital readmissions,disability,and falls. 展开更多
关键词 aortic stenosis FRAILTY transcatheter aortic valve replacement
下载PDF
Use of the reported Edmonton frail scale in the assessment of patients for transcatheter aortic valve replacement: a possible selection tool in very high-risk patients? 被引量:1
16
作者 Louis Koizia Sarosh Khan +3 位作者 Angela Frame Ghada W Mikhail Sayan Sen Neil Ruparelia 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2018年第6期463-466,共4页
Transcatheter aortic valve replacement (TAVR) has revolutionised the treatment of patients with aortic stenosis (AS) over the last 15 years.TAVR is a well-established procedure for the treatment of patients consid... Transcatheter aortic valve replacement (TAVR) has revolutionised the treatment of patients with aortic stenosis (AS) over the last 15 years.TAVR is a well-established procedure for the treatment of patients considered high risk for open surgery. Results from the PARTNER (Placement of AoRTic traNscathetER) trial showed that inoperable patients randomly assigned to TAVR, had a 20% reduction in all-cause mortality, as well as hospitalisation, at one year compared to best medical management. 展开更多
关键词 Edmonton frail scale FRAILTY transcatheter aortic valve replacement
下载PDF
Restrictive perimembranous ventricular septal defect with left to right Shunt post urgent aortic balloon valvuloplasty and transcatheter aortic valve replacement
17
作者 Emmanouil Chourdakis Ioanna Konlari +3 位作者 Nicholas G Kounis Dimitrios Velissaris George Hahalis Karl Eugen Hauptmann 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2018年第1期113-116,共4页
An 86-year-old male patient was admitted in our cardiology ward with signs of congestive biventricular heart failure. The patient presented with deteriorating dyspnea on mild exertion and at rest the last days, compat... An 86-year-old male patient was admitted in our cardiology ward with signs of congestive biventricular heart failure. The patient presented with deteriorating dyspnea on mild exertion and at rest the last days, compatible with class NYHA Ⅲ-Ⅳ heart failure, bilateral peripheral oedema, increased NT-proBNP (9198 pg/mL), mildly elevated Troponin (TnT 64 pg/mL), interstitial pulmonary oedema and bilateral pleural effusions in chest X ray. 展开更多
关键词 aortic stenosis aortic rupture SHUNT transcatheter aortic valve replacement VALVULOPLASTY Ventricular septal defect
下载PDF
Optimal C-arm angulation during transcatheter aortic valve replacement: Accuracy of a rotational C-arm computed tomography based three dimensional heart model
18
作者 Verena Veulemans Sabine Mollus +7 位作者 Axel Saalbach Max Pietsch Katharina Hellhammer Tobias Zeus Ralf Westenfeld Jürgen Weese Malte Kelm Jan Balzer 《World Journal of Cardiology》 CAS 2016年第10期606-614,共9页
AIMTo investigate the accuracy of a rotational C-arm CT-based 3D heart model to predict an optimal C-arm configuration during transcatheter aortic valve replacement (TAVR).METHODSRotational C-arm CT (RCT) under rapid ... AIMTo investigate the accuracy of a rotational C-arm CT-based 3D heart model to predict an optimal C-arm configuration during transcatheter aortic valve replacement (TAVR).METHODSRotational C-arm CT (RCT) under rapid ventricular pacing was performed in 57 consecutive patients with severe aortic stenosis as part of the pre-procedural cardiac catheterization. With prototype software each RCT data set was segmented using a 3D heart model. From that the line of perpendicularity curve was obtained that generates a perpendicular view of the aortic annulus according to the right-cusp rule. To evaluate the accuracy of a model-based overlay we compared model- and expert-derived aortic root diameters.RESULTSFor all 57 patients in the RCT cohort diameter measurements were obtained from two independent operators and were compared to the model-based measurements. The inter-observer variability was measured to be in the range of 0&#x000b0;-12.96&#x000b0; of angular C-arm displacement for two independent operators. The model-to-operator agreement was 0&#x000b0;-13.82&#x000b0;. The model-based and expert measurements of aortic root diameters evaluated at the aortic annulus (r = 0.79, P &#x0003c; 0.01), the aortic sinus (r = 0.93, P &#x0003c; 0.01) and the sino-tubular junction (r = 0.92, P &#x0003c; 0.01) correlated on a high level and the Bland-Altman analysis showed good agreement. The interobserver measurements did not show a significant bias.CONCLUSIONAutomatic segmentation of the aortic root using an anatomical model can accurately predict an optimal C-arm configuration, potentially simplifying current clinical workflows before and during TAVR. 展开更多
关键词 aortic stenosis Imaging modalities Degenerative valve disease transcatheter aortic valve replacement
下载PDF
Atrial electromechanical coupling parameters after transcatheter aortic valve replacement
19
作者 Mehmet Dogan Omer Yiginer +1 位作者 Fatih Ozcelik Alptug Tokatli 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2016年第6期557-558,共2页
The article entitled Effect of transcatheter aortic valve replacement on P-wave duration, P-wave dispersion and left atrial size by Dursun, et al. has contributed to our knowledge regarding the positive effects of tra... The article entitled Effect of transcatheter aortic valve replacement on P-wave duration, P-wave dispersion and left atrial size by Dursun, et al. has contributed to our knowledge regarding the positive effects of transcatheter aortic valve replacement (TAVR) procedure on atrial electrical remodeling. In this study, TAVR procedure led to a decrease on P-wave duration and P-wave dinner,inn 展开更多
关键词 Atrial fibrillation Electromechanical coupling P-wave dispersion transcatheter aortic valve replacement
下载PDF
Feasibility and clinical outcomes in nonagenarians undergoing transcatheter aortic valve replacement with the LOTUSTM valve
20
作者 Satish Ramkumar Hashrul N Rashid +4 位作者 Sarah Zaman Liam McCormick Robert Gooley Damon Jackson Ian T Meredith 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2016年第7期636-638,共3页
Surgical aortic valve replacement (AVR) is associated with very high peri-operative risk in the nonagenarian populationflI Patients with severe aortic stenosis treated conservatively have high rates of mortality wit... Surgical aortic valve replacement (AVR) is associated with very high peri-operative risk in the nonagenarian populationflI Patients with severe aortic stenosis treated conservatively have high rates of mortality with poor quality of life and loss of independence. Transcatheter aortic valve replacement (TAVR) has been validated in the high risk elderly population as a viable alternative to surgery with comparable outcomes. 展开更多
关键词 aortic valve replacement Nonagenarian patients transcatheter aortic valve replacement
下载PDF