期刊文献+
共找到77篇文章
< 1 2 4 >
每页显示 20 50 100
Predictive value of the trans-perineal three-dimensional ultrasound measurement of the pubic arch angle for vaginal delivery
1
作者 Zhu-Wei Liang Wan-Li Gao 《World Journal of Clinical Cases》 SCIE 2023年第20期4874-4882,共9页
BACKGROUND Numerous variables are linked to the success of vaginal delivery,including the subpubic arch angle(SPAA)during labor,the importance of which has not yet been fully elucidated.AIM To examine the SPAA distrib... BACKGROUND Numerous variables are linked to the success of vaginal delivery,including the subpubic arch angle(SPAA)during labor,the importance of which has not yet been fully elucidated.AIM To examine the SPAA distributional characteristics and to ascertain SPAA’s ability to predict the type and duration of labor.METHODS We determined the SPAA and analyzed the corresponding data.We also evaluated the relationship between the SPAA and the mode of delivery and the duration of labor by regression.The present study comprised a total of 301 pregnant women who had given birth at Beijing Tiantan Hospital of the Capital Medical University between January and December of 2021.RESULTS Our analysis of 301 pregnant women revealed that the SPAA measured using three-dimensional trans-perineal ultrasound had a minimum angle of 81°and a maximum angle of 122.2°.The angle in the normal vaginal delivery group was greater than that in the labor cesarean group(P=0.000).The SPAA was a highly significant positive predictor of normal vaginal delivery(P=0.000)with an area under the curve of 0.782(P=0.000;95%CI:0.717-0.848).We found the length of the second stage of labor to be positively influenced by the SPAA using linear regression analysis(P=0.045).CONCLUSION The SPAA was a highly significant positive predictor of normal vaginal delivery.The length of the second stage of labor and normal vaginal birth were predicted by SPAA. 展开更多
关键词 three-dimensional ultrasound Subpubic arch angle Trans-perineal Vaginal delivery
下载PDF
Catheter ablation of atrial fibrillation facilitated by preprocedural three-dimensional transesophageal echocardiography: Long-term outcome 被引量:3
2
作者 Klaus Kettering Felix Gramley Stephan von Bardeleben 《World Journal of Cardiology》 CAS 2017年第6期539-546,共8页
AIM To evaluate the long-term outcome of catheter ablation of atrial fibrillation(AF) facilitated by preprocedural threedimensional(3-D) transesophageal echocardiography.METHODS In 50 patients, 3D transesophageal echo... AIM To evaluate the long-term outcome of catheter ablation of atrial fibrillation(AF) facilitated by preprocedural threedimensional(3-D) transesophageal echocardiography.METHODS In 50 patients, 3D transesophageal echocardiography(3D TEE) was performed immediately prior to an ablation procedure(paroxysmal AF: 30 patients, persistent AF: 20 patients). The images were available throughout the ablation procedure. Two different ablation strategies were used. In most of the patients with paroxysmal AF, the cryoablation technique was used(Arctic Front Balloon, Cryo Cath Technologies/Medtronic; group A2). In the other patients, a circumferential pulmonary vein ablation was performed using the CARTO system [Biosense Webster; group A1(paroxysmal AF), group B(persistent AF)]. Success rates and complication rates were analysed at 4-year follow-up.RESULTS A 3D TEE could be performed successfully in all patients prior to the ablation procedure and all four pulmonaryvein ostia could be evaluated in 84% of patients. The image quality was excellent in the majority of patients and several variations of the pulmonary vein anatomy could be visualized precisely(e.g., common pulmonary vein ostia, accessory pulmonary veins, varying diameter of the left atrial appendage and its distance to the left superior pulmonary vein). All ablation procedures could be performed as planned and almost all pulmonary veins could be isolated successfully. At 48-mo followup, 68.0% of all patients were free from an arrhythmia recurrence(group A1: 72.7%, group A2: 73.7%, group B: 60.0%). There were no major complications.CONCLUSION3 D TEE provides an excellent overview over the left atrial anatomy prior to AF ablation procedures and these procedures are associated with a favourable long-term outcome. 展开更多
关键词 Pulmonary veins Catheter ablation Atrial fibrillation transesophageal echocardiography three-dimensional echocardiography
下载PDF
Surgical Resection of Mitral Valve Papillary Fibroelastoma: A Robot-Assisted, Minimally Invasive Approach with Three-Dimensional Transesophageal Echocardiography Imaging 被引量:1
3
作者 Crystal R. Bonnichsen Harold M. Burkhart +1 位作者 Kyle W. Klarich Rakesh M. Suri 《World Journal of Cardiovascular Surgery》 2012年第2期10-13,共4页
Papillary fibroelastomas (PFEs) are benign tumors of the endocardium that most frequently affect cardiac valves and typically present with embolic symptoms such as stroke or transient ischemic attack (TIA). Surgical e... Papillary fibroelastomas (PFEs) are benign tumors of the endocardium that most frequently affect cardiac valves and typically present with embolic symptoms such as stroke or transient ischemic attack (TIA). Surgical excision is usually recommended for left-sided tumors and is associated with excellent long-term outcomes. The use of a robot-assisted, minimally invasive surgical approach for management of mitral valve disease is growing, and has been associated with shorter hospital stays and improved early quality of life. Three-dimensional (3D) transesophageal echocardiography (TEE) offers several advantages in the assessment of mitral valve disease and cardiac tumors, including the ability to precisely locate the site of attachment of the mass and the spatial relationships to surrounding structures. These factors are particularly important when planning a surgical approach. We report two cases of mitral valve PFEs which were successfully removed using a robot-assisted, minimally invasive surgical approach with 3D TEE imaging. This approach to treatment of PFEs is an attractive alternative to the traditional approach involving median sternotomy. 展开更多
关键词 PAPILLARY FIBROELASTOMA ROBOTIC Surgery three-dimensional transesophageal ECHOCARDIOGRAPHY
下载PDF
Role of three-dimensional endoanal ultrasound in assessing the anal sphincter morphology of female patients with chronic proctalgia 被引量:9
4
作者 Ya-Hong Xue Shu-Qing Ding +1 位作者 Yi-Jiang Ding Li-Qun Pan 《World Journal of Gastroenterology》 SCIE CAS 2017年第21期3900-3906,共7页
AIM To assess the role of three-dimensional endoanal ultrasound (3D-EAUS) for morphological assessment of the anal sphincter of female patients with chronic proctalgia (CP). METHODS In this unmatched case control stud... AIM To assess the role of three-dimensional endoanal ultrasound (3D-EAUS) for morphological assessment of the anal sphincter of female patients with chronic proctalgia (CP). METHODS In this unmatched case control study, 30 consecutive female patients with CP and 25 normal women (control group) were enrolled. 3D-EAUS was performed in all subjects. Thickness and length of internal anal sphincter (IAS), thickness of puborectalis muscle (PR), length of the external anal sphincter (EAS) plus PR, and puborectalis angle were measured and compared between the two groups. RESULTS Patients with CP had significantly shorter IAS length and greater PR thickness, as compared to those in normal individuals (26.28 +/- 3.59 mm vs 28.87 +/- 4.84 mm, P < 0.05 and 9.67 +/- 1.57 mm vs 8.85 +/- 0.97 mm, P < 0.05, respectively). No significant between-group differences were observed with respect to IAS thickness and the EAS plus PR length (P > 0.05). Puborectalis angle in the CP group was significantly decreased, both in resting (88.23 degrees +/- 1.81 degrees vs 89.94 degrees +/- 2.07 degrees in control group, P < 0.05) and straining (88.47 degrees +/- 3.32 degrees vs 90.72 degrees +/- 1.87 degrees in control group, P < 0.05) phases, which suggest the presence of paradoxical contraction of PR in patients with CP. In the CP group, no significant difference in puborectalis angle was observed between the resting and straining phases (88.23 degrees +/- 1.81 degrees vs 88.47 degrees +/- 3.32 degrees respectively, P > 0.05). CONCLUSION The association of greater PR thickness and paradoxical contraction of PR with CP suggest their potential value as markers of CP. 展开更多
关键词 chronic proctalgia three-dimensional endoanal ultrasound puborectalis angle internal anal sphincter puborectalis muscle
下载PDF
Detection of Congenital Uterine Malformation by Using Transvaginal Three-dimensional Ultrasound 被引量:7
5
作者 于利利 张璇 +2 位作者 章婷 陈汉荣 王泽华 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2014年第5期782-784,共3页
This study assessed the clinical application of transvaginal three-dimensional ultrasound (3D TVUS) in the diagnosis of congenital uterine malformation. A retrospective study was performed on 62 patients with congen... This study assessed the clinical application of transvaginal three-dimensional ultrasound (3D TVUS) in the diagnosis of congenital uterine malformation. A retrospective study was performed on 62 patients with congenital uterine malformation confirmed hysteroscopically and/or laparoscopically. The patients were subjected to transvaginal two-dimensional ultrasound (2D TVUS) and 3D TVUS. The accuracy rate was compared between the two methods. The accuracy rate of 3D TVUS was (98.38%, 61/62), higher than that of 2D TVUS (80.65%, 50/62). 3D TVUS coronal plane imaging could demon- strate the internal shape of the endometrial cavity and the external contour of the uterine fundus. It al- lowed accurate measurement on the coronary plane, and could three-dimensionally show the image of cervical tube, thereby providing information for the diagnosis of some complex uterine malformation. 3D TVUS imaging can obtain comprehensive information of the uterus malformation, and it is superior to 2D TVUS for the diagnosis of congenital uterine malformations, especially complex uterine anomaly. 展开更多
关键词 congenital uterine malformation transvaginal three-dimensional ultrasound coronary plane
下载PDF
Sequential transcatheter arterial chemoembolization,three-dimensional conformal radiotherapy,and high-intensity focused ultrasound treatment for unresectable hepatocellular carcinoma patients 被引量:9
6
作者 Shengfa Ni Lingxiang Liu Yongqian Shu 《The Journal of Biomedical Research》 CAS 2012年第4期260-267,共8页
The purpose of this study was to evaluate the outcome of patients with unresectable hepatocellular carcinoma(HCC) treated by sequential therapy of transcatheter arterial chemoembolization(TACE),three-dimensional c... The purpose of this study was to evaluate the outcome of patients with unresectable hepatocellular carcinoma(HCC) treated by sequential therapy of transcatheter arterial chemoembolization(TACE),three-dimensional conformal radiotherapy(3-DCRT) and high-intensity focused ultrasound(HIFU).From October,2005 to September,2010,120 patients with unresectable HCC received the sequential treatments of several courses of TACE followed in 2-4 weeks by 3-DCRT and then a single session of HIFU with a curative intent.The median tumor irradiation dose was 40 Gy.Tumor response,toxicity and overall survival rate were analyzed.Clinicopathologic factors affecting the primary technique effectiveness and overall survival rates were investigated by univariate analysis or multivariate analysis.All 120 HCC patients were followed up by the last follow-up time.Among these patients,hepatic toxicities due to treatment were notable in 9 cases.Gastrointestinal bleeding after the overall treatment occurred in 2 cases,leukopenia of grade III was detected in 1 case,radiation-induced liver disease(RILD) was observed in 2 patients,and first-and second-degree skin burn around the HIFU treatment zone were observed in 2 patients and 1 patient,respectively.Among 120 patients,23,83 and 14 cases achieved partial response,stable disease and progressive disease,respectively.The overall survival rates at 1 year,3 years and 5 years were 70%,35% and 15%,respectively,with a median survival time of 26 months.Both Child-Pugh liver function grading and radiation dose were determined to be independent predictors for overall survival revealed by the multivariate analysis.It is concluded that the sequential therapy of TACE,3-DCRT and HIFU is a promising therapeutic regimen for unresectable HCC. 展开更多
关键词 transcatheter arterial chemoembolization(TACE) three-dimensional con-formal radiotherapy(3DCRT) high-intensity focused ultrasound(HIFU) hepatocellular carcinoma
下载PDF
Prenatal Diagnosis of Sirenomelia by Two-Dimensional and Three-Dimensional Skeletal Imaging Ultrasound 被引量:1
7
作者 刘蓉 陈欣林 +1 位作者 杨小红 马慧静 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 2015年第6期928-931,共4页
Summary: This study sought to evaluate the contribution of two-dimensional ultrasound (2D-US) and three-dimensional skeletal imaging ultrasound (3D-SUIS) in the prenatal diagnosis of sirenomelia. Be- tween Septem... Summary: This study sought to evaluate the contribution of two-dimensional ultrasound (2D-US) and three-dimensional skeletal imaging ultrasound (3D-SUIS) in the prenatal diagnosis of sirenomelia. Be- tween September 2010 and April 2014, a prospective study was conducted in a single referral center using 3D-SU1S performed after 2D-US in 10 cases of sirenomelia. Diagnostic accuracy and detailed findings were compared with postnatal three-dimensional helical computed tomography (3D-HCT), radiological findings and autopsy. Pregnancy was terminated in all 10 sirenomelia cases, including 9 singletons and I conjoined twin pregnancy, for a total of 5 males and 5 females. These cases of sirenomelia were deter- mined by autopsy and/or chromosomal examination. Initial 2D-US showed that there were 10 cases of oligohydranmios, bilateral renal agenesis, bladder agenesis, single umbilical artery, fusion of the lower limbs and spinal abnormalities; 8 cases of dipus or monopus; 2 cases of apus; and 8 cases of cardiac abnormalities. Subsequent 3D-SUIS showed that there were 9 cases of scoliosis, l0 cases of sacrococ- cygeal vertebra dysplasia, 3 cases of hemivertebra, 1 case of vertebral fusion, 3 cases of spina bifida, and 5 cases of rib abnormalities. 3D-SUIS identified significantly more skeletal abnormalities than did 2D-US, and its accuracy was 79.5% (70/88) compared with 3D-HCT and radiography. 3D-SUIS seems to be a useful complementary method to 2D-US and may improve the accuracy of identifying prenatal skeletal abnormalities related to sirenomelia. 展开更多
关键词 SIRENOMELIA three-dimensional skeletal imaging ultrasound three-dimensional helicalcomputed tomography
下载PDF
Three-dimensional psychological guidance combined with evidencebased health intervention in patients with liver abscess treated with ultrasound
8
作者 Ya-Nan Shan Ying Yu +2 位作者 Yi-Han Zhao Lian-Lian Tang Xiao-Min Chen 《World Journal of Clinical Cases》 SCIE 2022年第23期8196-8204,共9页
BACKGROUND Liver abscess is a common clinical liver disease mainly caused by suppurative bacteria or amoebae,with early clinical signs of chills,high fever,jaundice,and other symptoms.Establishing its early diagnosis ... BACKGROUND Liver abscess is a common clinical liver disease mainly caused by suppurative bacteria or amoebae,with early clinical signs of chills,high fever,jaundice,and other symptoms.Establishing its early diagnosis is difficult,which may lead to misdiagnosis.AIM To observe the effects of psychological guidance combined with evidence-based health intervention in patients with liver abscess treated with ultrasound.METHODS A total of 120 patients with bacterial liver abscess admitted to our hospital from May 2018 to February 2021 were selected and divided into groups according to their intervention plan.RESULTS After the intervention,Self-Rating Depression Scale,Self-Rating Anxiety Scale,Self-Perceived Burden Scale(SPBS),and quality of life scores(physical functioning,role physical,bodily pain,general health,vitality,social functioning,role emotional,mental health)were lower than before the intervention in the two groups.The observation group had lower negative sentiment,SPBS,and quality of life scores than the control group.In the observation group,31 and 24 patients had good and general compliance,respectively,with a compliance rate of 91.67%,which was significantly higher than that in the control group.The observation group had significantly lower total incidence of incision infection,abdominal abscess,hemorrhage,and severe abdominal pain than the control group.CONCLUSION Three-dimensional psychological guidance combined with evidence-based health intervention in treating liver abscess can reduce patients’burden and negative emotions,improve patient compliance and quality of life,and reduce complications. 展开更多
关键词 three-dimensional psychological guidance Evidence-based health intervention ultrasound intervention Liver abscess Negative emotions COMPLIANCE
下载PDF
Changes in three-dimensional power Doppler ultrasound features before and after neoadjuvant chemotherapy for cervical cancer and their relationship with malignant molecule expression
9
作者 Ju-Hua Pan Ye-Qing Ren Qing-Lian Ma 《Journal of Hainan Medical University》 2019年第11期69-74,共6页
Objective:To study the changes in three-dimensional power Doppler ultrasound features before and after neoadjuvant chemotherapy for cervical cancer and their relationship with malignant molecule expression.Methods: Th... Objective:To study the changes in three-dimensional power Doppler ultrasound features before and after neoadjuvant chemotherapy for cervical cancer and their relationship with malignant molecule expression.Methods: The patients who were diagnosed with cervical cancer and received neoadjuvant chemotherapy in Wuhan Red Cross Hospital between March 2015 and October 2017 were selected as the cervical cancer group, and the patients who received cervical biopsy and were diagnosed with stage I cervical intraepithelial neoplasia by pathological findings during the same period were selected as the control group. Before biopsy, three-dimensional power Doppler ultrasonography was performed to measure VI, FI and VFI;the tissues of cervical cancer group before and after chemotherapy as well as the biopsy tissues of control group were collected to measure the expression of proliferation genes, invasion genes and angiogenesis genes.Results: The VI, FI and VFI levels as well as the Piwil2 gene (Piwil2), CyclinD1, N-Myc downstream regulated gene 3 (NDRG3), CXC chemokine ligand 5 (CXCL5), cathepsin-L (CAT-L), EGF-containing fibulin-like extracellular matrix protein 1 (EFEMP1), angiotensin (Ang)1, Ang2 and angiopoietin-like protein 4 (ANGPTL4) mRNA expression levels in the tissues of cervical cancer group before and after chemotherapy were all significantly higher than those of control group whereas the thrombospondin 2 (THBS2), Smac gene (Smac), large tumor suppressor kinase 1 (LATS1), reversion-inducing-cysteine-rich protein with kazal motifs (RECK) and plas minogen activator inhibitor 1 (PAI-1) mRNA expression levels in the tissues were all significantly lower than those of control group, and the VI, FI and VFI levels as well as the Piwil2, CyclinD1, NDRG3, CXCL5, CAT-L, EFEMP1, Ang1, Ang2 and ANGPTL4 mRNA expression levels in the tissues of cervical cancer group after chemotherapy were all significantly lower than those before chemotherapy whereas the THBS2, Smac, LATS1, RECK and PAI-1 mRNA expression levels were all significantly higher than those before chemotherapy;the VI, FI and VFI levels in cervical cancer tissues were positively correlated with the Piwil2, CyclinD1, NDRG3, CXCL5, CAT-L, EFEMP1, Ang1, Ang2 and ANGPTL4 mRNA expression levels, and negatively correlated with the THBS2, Smac, LATS1, RECK and PAI-1 mRNA expression levels.Conclusion: The changes in the three-dimensional power Doppler ultrasound parameters before and after neoadjuvant chemotherapy for cervical cancer can reflect the changes in proliferation, invasion and angiogenesis gene expression in the lesions. 展开更多
关键词 CERVICAL cancer three-dimensional power Doppler ultrasound Proliferation INVASION ANGIOGENESIS
下载PDF
Value of myocardial function in children with Kawasaki disease by two-dimensional and three-dimensional ultrasound speckle tracking
10
作者 Ya-Mei Shen Tao-Min Bai +4 位作者 Xue-Mei Zhang Chun-Miao Kang Xiao-Ni Chang Yan-Hua Gao Xiao-Hua Yan 《Journal of Hainan Medical University》 2019年第21期58-61,共4页
Objective:To investigate the value of two-dimensional ultrasound speckle tracking(2D-STI)and three-dimensional ultrasound speckle tracking(3D-STI)in evaluating myocardial function in children with Kawasaki disease.Met... Objective:To investigate the value of two-dimensional ultrasound speckle tracking(2D-STI)and three-dimensional ultrasound speckle tracking(3D-STI)in evaluating myocardial function in children with Kawasaki disease.Methods 92 children with Kawasaki disease admitted to our hospital from February 2017 to February 2019 were retrospectively analyzed.50 children who underwent 3D-STI examination were taken as observation group and 42 children who underwent 2D-STI examination were taken as control group.The left ventricular systolic function index,storage time and analysis time of the image,the diameter of coronary artery,the strain difference of left ventricular basal segment,middle segment,apical segment and whole segment were observed.Results The levels of left ventricular end-diastolic volume(LVEDV),left ventricular end-systolic volume(LVESV),left ventricular myocardial mass(LVMI)in the observation group were higher than those in the control group(P<0.05),but there was no statistical difference in left ventricular ejection fraction(LVEF)between the two groups(P>0.05).The storage time and analysis time of the image in the observation group were significantly lower than those in the control group(P<0.05).The left coronary artery(LCA)and right coronary artery(RCA)in the observation group were higher than those in the control group(P<0.05).There was no statistical difference between left anterior descending(LAD)in the two groups(P>0.05).The longitudinal peak systolic strain(LS),circumferential peak systolic strain(CS)and radial peak systolic strain(RS)in the observation group were higher than those in the control group(P<0.05).The global longitudinal peak strain(GLS),global circumferential peak strain(GCS)and global radial peak strain(GRS)in the observation group were higher than those in the control group(P<0.05).LS and CS in the middle segment of the observation group were higher than those in the control group(P<0.05).Conclusions Compared with 2D-STI,3D-STI can objectively and accurately reflect the myocardial function of children with Kawasaki disease. 展开更多
关键词 KAWASAKI disease TWO-DIMENSIONAL ultrasound SPECKLE TRACKING three-dimensional ultrasound SPECKLE TRACKING myocardial FUNCTION left ventricular systolic FUNCTION
下载PDF
Correlation analysis of real-time three-dimensional ultrasound in diagnosis of left ventricular function, portal hemodynamics and severity of liver function in patients with liver cirrhosis
11
作者 Lin Li Hong-Ying Zhu He-Juan Du 《Journal of Hainan Medical University》 2019年第12期67-70,共4页
Objective:To analyze the correlation between real-time three-dimensional ultrasound in diagnosis of left ventricular function, portal hemodynamics and severity of liver function in patients with liver cirrhosis.Method... Objective:To analyze the correlation between real-time three-dimensional ultrasound in diagnosis of left ventricular function, portal hemodynamics and severity of liver function in patients with liver cirrhosis.Methods: 90 patients with cirrhosis admitted to our hospital from January 2017 to December 2018 were enrolled in the cirrhosis group, and the cirrhosis components were group A, B and C according to the Child-Pauh classification criteria. During the same period, 90 healthy subjects who underwent physical examination were selected as the control group;real-time three-dimensional ultrasonography was performed to examine left ventricular function and portal hemodynamic parameters;Pearson correlation was used to analyze left ventricular function, portal hemodynamics and liver. Functional severity relationship.Results: The left heart E and E/A levels in the cirrhosis group were significantly lower than those in the control group (P<0.05), and the A level was significantly higher than the control group (P<0.05). The Dpv and Q levels in the cirrhosis group were significantly higher than those in the healthy control group. The difference was statistically significant (P<0.05), and the level of Vpv was significantly lower than that of healthy controls (P<0.05). There were significant differences in E, A and E/A levels between different Child-Paugh patients (P<0.05). There were significant differences in portal hemodynamics Dpv, Vpv and Q between the different Child-Paugh grades, and the difference was statistically significant (P<0.05);left heart function E and E/A and liver function severity There was a significant negative correlation (P<0.05). There was a significant positive correlation between left cardiac function A and liver function severity (P<0.05). Portal vein hemodynamics Dpv, Vpv and QE were significantly associated with liver function severity. Positive correlation (P<0.05). Conclusion: Real-time three-dimensional ultrasound can effectively detect left ventricular function and portal hemodynamics changes in patients with cirrhosis, and left heart function, portal hemodynamics and liver function severity are significantly correlated. 展开更多
关键词 REAL-TIME three-dimensional ultrasound CIRRHOSIS Left VENTRICULAR FUNCTION Portal HEMODYNAMICS Liver FUNCTION
下载PDF
Radiologic-pathologic correlation of three-dimensional shear-wave elastographic findings in assessing the liver ablation volume after radiofrequency ablation 被引量:10
12
作者 Katsutoshi Sugimoto Hisashi Oshiro +3 位作者 Saori Ogawa Mitsuyoshi Honjo Takeshi Hara Fuminori Moriyasu 《World Journal of Gastroenterology》 SCIE CAS 2014年第33期11850-11855,共6页
AIM: To evaluate the usefulness of three-dimensional (3D) shear-wave elastography (SWE) in assessing the liver ablation volume after radiofrequency (RF) ablation.
关键词 Radiofrequency ablation LIVER ultrasound Shear-wave elastography three-dimensional
下载PDF
Antidiastole Value of Three-dimensional Ultrasonography and Power Doppler between Uterine Parenchyma Lumps and Endometrial Cancer:A Retrospective Study 被引量:11
13
作者 Yan ZHANG Jing CHEN +1 位作者 Zeng ZHEN Xiao-yan XU 《Current Medical Science》 SCIE CAS 2019年第5期816-819,共4页
Sometimes endometrial polyps,submucosal myomas,and endometrial cancer show similar findings under ultrasonography.The aim of this study was to assess the antidiastole value of blood flow parameters using three-dimensi... Sometimes endometrial polyps,submucosal myomas,and endometrial cancer show similar findings under ultrasonography.The aim of this study was to assess the antidiastole value of blood flow parameters using three-dimensional(3D)power Doppler ultrasonography angiography(PDA)between endometrial cancer and uterine parenchyma lumps.The data of the blood flow indices in 3D-PDA including the vascularization index(VI),flow index(FI),and vascularization flow index(VFI)in 40 patients with endometrial cancer and 41 patients with uterine parenchyma lumps(endometrial polyps and submucosal myomas)were retrospectively analysed and compared utilizing Virtual Organ Computer-aided AnaLysis(VOCAL)software.The results showed that all the blood flow parameters(VI,FI,VFI)were significantly higher in women with endometrial cancer than in those with uterine parenchyma lumps(P<0.001).The area under the curve of ROC of VI,FI,and VFI was 0.98,0.84,and 0.97,respectively.Thus,the best predictor of endometrial carcinoma was VI with a sensitivity of 97.0% and a specificity of 91.0%.The optimal cutoff value of VI was 4.06%.Our data demonstrated that all of the blood flow signal parameters(including VI,FI,and VFI)in 3D power Doppler ultrasonography had significant antidiastole values between endometrial cancer and uterine parenchyma lumps to assist clinicians in properly diagnosing patients. 展开更多
关键词 power DOPPLER three-dimensional ultrasound UTERINE PARENCHYMA lump ENDOMETRIAL CARCINOMA BLOOD flow signal parameter
下载PDF
Three-dimensional imaging of the uterus:The value of the coronal plane 被引量:3
14
作者 Lufee Wong Nikki White +3 位作者 Jayshree Ramkrishna Edward Araujo Júnior Simon Meagher Fabricio Da Silva Costa 《World Journal of Radiology》 CAS 2015年第12期484-493,共10页
Advent in three-dimensional(3D) imaging technology has seen 3D ultrasound establish itself as a useful adjunct complementary to traditional two-dimensional imaging of the female pelvis. This advantage largely arises f... Advent in three-dimensional(3D) imaging technology has seen 3D ultrasound establish itself as a useful adjunct complementary to traditional two-dimensional imaging of the female pelvis. This advantage largely arises from its ability to reconstruct the coronal plane of the uterus, which allows further delineation of many gynecological disorders. 3D imaging of the uterus is now the preferred imaging modality for assessing congenital uterine anomalies and intrauterine device localization. Newer indications include the diagnosis of adenomyosis. It can also add invaluable information to delineate other endometrial and myometrial pathology such as fibroids and endometrial polyps. 展开更多
关键词 three-dimensional ultrasound Coronal view PELVIS UTERUS Uterine anomalies
下载PDF
Study on Three Dimensional Reconstruction of Transesophageal Echocardiographic Images 被引量:1
15
作者 李治安 王新房 +3 位作者 陆平 胡刚 郑莉慧 杨娅 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1995年第1期10-15,共6页
Using biplane transesophageal echocardiography and the concept of three dimensional transthoracic echocardiography,we performed three dimensional reconstruction of transesophageal images of various clinicopathologic c... Using biplane transesophageal echocardiography and the concept of three dimensional transthoracic echocardiography,we performed three dimensional reconstruction of transesophageal images of various clinicopathologic cases,including atrial septal defect,mitral stenosis,mitral valve prolapse and pulmonary stenosis.The hardware equipments and image processing flow chart of three dimensional reconstruction of transesophageal echocardiographic images are described. Our present study indicates that three dimensional reconstruction of transesophageal echocardiographic images could display multi-regional three dimensional structures of heart and great vessels,including superior vena cava,ascending aorta,right ventricular outflow tract, pulmonary artery and left heart,with clear,visual and stereoscopic imaging.The regional structures could be displayed at different levels of stereo-anatomic-sec-tions and in different orientations of rotating stereo-images,which could provide accurate three dimensional anatomical information for cardiac stereo-morphological study and definition of spatial location and size of cardiac abnormalities. 展开更多
关键词 three-dimensional reconstruction transesophageal echocardiography(TEE) transthoracic echocardiography(TTE)
下载PDF
Clinical Application of Three-dimensional Transesophageal Echocardiography in the Diagnosis of Atrial Septal Defect
16
作者 郑俐慧 李治安 +3 位作者 王新房 胡纲 杨娅 刘俐 《Journal of Huazhong University of Science and Technology(Medical Sciences)》 SCIE CAS 1996年第3期183-185,共3页
This paper reports the use of three-dimensional (3-D) transesophageal echocardiography(TEE) in the diagnosis of atrial septal defect. The results displayed that the interatrial septum had integrity in normal persons. ... This paper reports the use of three-dimensional (3-D) transesophageal echocardiography(TEE) in the diagnosis of atrial septal defect. The results displayed that the interatrial septum had integrity in normal persons. The size,shape and position of atrial septal defects could be showed clearly and the type of the defects could be identified. The reconstructed imaging of interatrial septum on 3-D TEE was clear and stereoscopic. The technique is helpful in defining spatial location and extent of atrial septal defects. 展开更多
关键词 three-dimensional transesophageal echocardiography atrial septal Defect
下载PDF
Geometric comparison of the mitral and tricuspid valve annulus:Insights from three dimensional transesophageal echocardiography
17
作者 Amgad N Makaryus Haisam Ismail +1 位作者 John N Makaryus Dali Fan 《World Journal of Cardiology》 CAS 2017年第9期757-760,共4页
AIM To apply real time three-dimensional transesophageal echocardiography(RT3D TEE) for quantitative and qualitative assessment of the mitral valve annulus(MVA) and tricuspid valve annulus(TVA) in the same patient.MET... AIM To apply real time three-dimensional transesophageal echocardiography(RT3D TEE) for quantitative and qualitative assessment of the mitral valve annulus(MVA) and tricuspid valve annulus(TVA) in the same patient.METHODS Our retrospective cohort study examined the MVA and TVA in 49 patients by RT3 D TEE. MVA and TVA shape were examined by TEE. The MVA and TVA volume data set images were acquired in the mid esophageal 4-chamber view. The MVA and TVA were acquired separately, with optimization of each for the highest frame rate and image quality. The 3D shape of the annuli was reconstructed using the Philips~? Q lab, MVQ ver. 6.0 MVA model software. The end-systolic frame was used. The parameters measured and compared were annular area, circumference, high-low distances(height), anterolateralposterolateral(ALPM), and anteroposterior(AP) axes. RESULTS A total of 49 patients(mean age 61 ± 14 years, 45% males) were studied. The ALPM and the AP axes of the MVA and TVA are not significantly different. The ALPM axis of the MVA was 37.9 ± 6.4 mm and 38.0 ± 5.6 mm for the TVA(P = 0.70). The AP axis of the MVA was 34.8 ± 5.7 mm and 34.9 ± 6.2 mm for the TVA(P = 0.90). The MVA and the TVA had similar circumference and area. The circumference of the MVA was 127.9 ± 16.8 mm and 125.92 ± 16.12 mm for the TVA(P = 0.23). The area of the MVA was 1103.7 ± 307.8 mm^2 and 1131.7 ± 302.0 mm^2 for the TVA(P = 0.41). The MVA and TVA are similar oval structures, but with significantly different heights. The ALPM/AP ratio for the MVA was 1.08 ± 0.33 and 1.09 ± 0.28 for the TVA(P < 0.001). The height for the MVA and TVA was 9.23 ± 2.11 mm and 4.37 ± 1.48 mm, respectively(P < 0.0001). CONCLUSION RT3 D TEE plays an unprecedented role in the management of valvular heart disease. The specific and exclusive shape of the MVA and TVA was revealed in our study of patients studied. Moreover, the intricate codependence of the MVA and the TVA depends on their distinctive shapes. This realization seen from our study will allow us to better understand the role valvular disease plays in disease states such as hypertrophic cardiomyopathy and pulmonary hypertension. 展开更多
关键词 Mitral valve annulus Tricuspid valve annulus Three dimensional imaging Real time three-dimensional transesophageal echocardiography
下载PDF
卵圆孔未闭合并脑梗死的危险因素及经食道超声引导下的封堵价值
18
作者 张青 马宁帅 张宁 《川北医学院学报》 CAS 2024年第8期1127-1131,共5页
目的:探讨卵圆孔未闭合并脑梗死的危险因素及经食道超声引导下的封堵价值。方法:选取120例卵圆孔未闭患者为研究对象,依据是否发生脑梗死分为单纯卵圆孔未闭组(n=78)和卵圆孔未闭合并脑梗死组(n=42);卵圆孔未闭合并脑梗死组再根据治疗... 目的:探讨卵圆孔未闭合并脑梗死的危险因素及经食道超声引导下的封堵价值。方法:选取120例卵圆孔未闭患者为研究对象,依据是否发生脑梗死分为单纯卵圆孔未闭组(n=78)和卵圆孔未闭合并脑梗死组(n=42);卵圆孔未闭合并脑梗死组再根据治疗方式不同分为常规治疗组(n=18)和介入封堵组(n=24)。分析卵圆孔未闭合并脑梗死的危险因素;比较卵圆孔未闭合并脑梗死组不同治疗方式患者的临床疗效、头痛程度[头痛影响测评量表6(HIT-6)评分]和脑梗死相关并发症发生情况。结果:单因素及多因素分析显示,年龄、患有高血压和糖尿病、红细胞分布宽度变异系数和纤维蛋白原异常是卵圆孔未闭患者发生脑梗死的危险因素(P<0.05)。介入封堵组患者治疗总有效率高于常规治疗组(83.33%vs.50.00%,P<0.05);HIT-6评分低于常规治疗组[(32.15±4.08)分vs.(47.26±4.63)分,P<0.05];脑梗死相关症状并发症发生率低于常规治疗组(4.17%vs.44.44%,P<0.05)。结论:高龄、患有高血压和糖尿病、红细胞分布宽度变异系数及纤维蛋白原指标异常均是卵圆孔未闭患者发生脑梗死的危险因素;经食道超声引导下的封堵术能提高卵圆孔未闭合并脑梗死患者的临床疗效,降低头痛程度和脑梗死相关症并发症的发生率,值得临床推广应用。 展开更多
关键词 卵圆孔未闭 脑梗死 危险因素 分析 经食道超声引导 封堵 价值
下载PDF
经食管超声心动图评价卵圆孔未闭合并心房颤动左心耳改变对主要心脑血管不良事件的相关因素研究
19
作者 王旭 王俊伟 杜利军 《中国心血管病研究》 CAS 2024年第4期317-322,共6页
目的探讨经食管超声心动图评价卵圆孔未闭合并心房颤动(房颤)左心耳改变对主要心脑血管不良事件(MACCE)的相关因素研究。方法选取2021年3月~2023年1月邯郸市第一医院收治的167例卵圆孔未闭合并房颤患者进行回顾性研究,根据6个月内MACCE... 目的探讨经食管超声心动图评价卵圆孔未闭合并心房颤动(房颤)左心耳改变对主要心脑血管不良事件(MACCE)的相关因素研究。方法选取2021年3月~2023年1月邯郸市第一医院收治的167例卵圆孔未闭合并房颤患者进行回顾性研究,根据6个月内MACCE发生情况分为MACCE组和无MACCE组。比较两组基线资料、左心耳射血分数(LAAEF)、左心耳血流平均排空速度(LAA-AEV)、左心耳最大容积(LAAVmax)、左心耳血流峰值排空速度(LAA-EV)、左心耳血流峰值充盈速度(LAA-FV)、左心耳血流平均充盈速度(LAA-AFV)、左心耳开口面积(LAA-O)、左心耳长径(LAA-L)、左心耳宽度(LAA-W),以随机森林算法对MACCE特征变量进行重要性排序,ROC分析经食管超声心动图参数预测MACCE价值。结果MACCE组短暂性脑缺血发作史占比高于无MACCE组(27.27%比5.97%,P<0.05);MACCE组LAAEF[(37.28±12.05)%比(49.20±10.34)%]、LAA-AEV[(29.43±7.29)cm/s比(39.66±10.53)cm/s]、LAA-AFV[(24.35±5.82)cm/s比(35.29±9.10)cm/s]低于无MACCE组,LAA-W[(21.13±4.29)mm比(18.74±3.06)mm]、自发显影判定分级高于无MACCE组(P<0.05);将单因素分析P<0.05变量作为随机森林算法的构成变量,逐步随机森林分析显示,MACCE特征重要排序前5变量预测因素为自发显影判定分级、LAA-AEV、LAA-AFV、LAAEF、LAA-W;ROC曲线显示,显影判定分级、LAA-AEV、LAA-AFV、LAAEF、LAA-W联合的AUC大于各参数单独预测,其中单一参数中自发显影判定分级的AUC最大。结论卵圆孔未闭合并房颤患者采用经食管超声心动图观察其左心耳变化,自发显影判定分级、LAA-AEV、LAA-AFV、LAAEF、LAA-W联合预测患者MACCE具有较高价值。 展开更多
关键词 经食管超声心动图 卵圆孔未闭 心房颤动 左心耳 主要心脑血管不良事件
下载PDF
心外膜脂肪厚度联合左心耳功能参数在预测阵发性房颤射频消融术后复发的价值
20
作者 李东婉 王华 《生物医学工程与临床》 CAS 2024年第5期683-688,共6页
目的探讨基于心外膜脂肪厚度(EFT)联合左心耳(LAA)功能参数的诊断模型在预测阵发性房颤(AF)患者射频消融术后复发的价值。方法收集行射频消融手术的阵发AF患者47例,其中男性22例,女性25例;年龄41~77岁,平均年龄62.72岁;身体质量指数(BMI... 目的探讨基于心外膜脂肪厚度(EFT)联合左心耳(LAA)功能参数的诊断模型在预测阵发性房颤(AF)患者射频消融术后复发的价值。方法收集行射频消融手术的阵发AF患者47例,其中男性22例,女性25例;年龄41~77岁,平均年龄62.72岁;身体质量指数(BMI)18.0~29.6 kg/m^(2),平均BMI 25.26 kg/m^(2);高血压24例,糖尿病5例,冠心病13例,卒中或短暂性脑缺血发作(TIA)6例;低密度脂蛋白1.30~3.86 mmol/L,平均低密度脂蛋白2.29 mmol/L;高密度脂蛋白0.67~1.59 mmol/L,平均高密度脂蛋白1.07 mmol/L;血尿酸123.0~514.0μmol/L,平均血尿酸303.70μmol/L。术前进行经胸超声心动图(TTE)和经食管超声心动图(TEE)检查。术后3个月开始随访,将患者分为复发组与未复发组。通过单因素及主成分分析的方法探索阵发性AF术后复发的预测因子并建立预测术后复发的联合诊断模型。结果单因素分析中,两组年龄、BMI、左心房(LA)前后径、EFT、LAA最大开口内径相比,复发组高于非复发组,差异有统计学意义[71(61.01,73.75)岁vs 65(54.25,69.02)岁、(26.81±2.19)kg/m^(2)vs(24.84±2.83)kg/m^(2)、(43.42±4.58)mm vs(40.34±4.16)mm、5.63(5.30,5.99)mm vs 4.15(3.67,5.03)mm、(21.24±3.67)mm vs(18.37±2.81)mm。P<0.05];复发组LAA排空速度、LAA充盈速度、LAA峰值应变低于非复发组,差异有统计学意义[33.55(27.93,40.28)cm/s vs 43.40(33.70,77.63)cm/s、(35.06±11.02)cm/s vs(45.26±14.86)cm/s、5.85(5.18,7.08)vs 9.90(8.70,13.10)。P<0.05]。采用主成分分析法构建的联合诊断模型综合评分截断值为16.695时,诊断阵发性AF射频消融术后复发的曲线下面积为0.895,对应的灵敏度、特异度、准确度分别为90.0%、78.4%、82.9%。结论EFT联合LAA功能参数在预测阵发性AF射频消融术后复发中有一定的诊断价值。 展开更多
关键词 心外膜脂肪厚度 经食管超声 左心耳 阵发性房颤
下载PDF
上一页 1 2 4 下一页 到第
使用帮助 返回顶部