In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line select...In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line selection always existed in existing methods. According to the characteristics that transient current was different between the fault feeder and other faultless feeders, wavelet transformation was performed on data of the transient current within a power frequency cycle after the fault occurred. Based on different fault angles, wavelet energy in corresponding frequency band was chosen to compare. The result was that wavelet energy in fault feeder was the largest of all, and it was larger than sum of those in other faultless feeders, when the bus broke down, the disparity between each wavelet energy was not significant. Fault line could be selected out by the criterion above. The results of MATLAB/simulink simulation experiment indicated that this method had anti-interference capacity and was feasible.展开更多
The Floating nuclear power plant grid is composed of power generation,in-station power supply and external power delivery.To ensure the safety of the nuclear island,the in-station system adopts a special power supply ...The Floating nuclear power plant grid is composed of power generation,in-station power supply and external power delivery.To ensure the safety of the nuclear island,the in-station system adopts a special power supply mode,while the external power supply needs to be adapted to different types of external systems.Because of frequent single phase-ground faults and various fault forms,the fault line selection protection should be accurate,sensitive and adaptive.This paper presents a fault line selection method in cooperation with multi-mode grounding control.Based on the maximum united energy entropy ratio(MUEER),the optimal wavelet basis function and decomposition scale are adaptively chosen,while the fault line is selected by wavelet transform modulus maxima(WTMM).For high-impedance faults(HIFs),to enlarge the fault feature,the system grounding mode can be switched by the multi-mode grounding control.Based on the characteristic of HIFs,the fault line can be selected by comparing phase differences of zero-sequence current mutation and fault phase voltage mutation before and after the fault.Simulation results using MATLAB/Simulink show the effectiveness of the proposed method in solving the protection problems.展开更多
文摘In the distribution network system with its neutral point grounding via arc suppression coil, when single-phase grounding fault occurred near zero-crossing point of the phase voltage, the inaccuracy of the line selection always existed in existing methods. According to the characteristics that transient current was different between the fault feeder and other faultless feeders, wavelet transformation was performed on data of the transient current within a power frequency cycle after the fault occurred. Based on different fault angles, wavelet energy in corresponding frequency band was chosen to compare. The result was that wavelet energy in fault feeder was the largest of all, and it was larger than sum of those in other faultless feeders, when the bus broke down, the disparity between each wavelet energy was not significant. Fault line could be selected out by the criterion above. The results of MATLAB/simulink simulation experiment indicated that this method had anti-interference capacity and was feasible.
基金Project Supported by National Natural Science Foundation of China(No.51877089).Research on the mechanism and fault ride-through integrated strategies of an active power router in hybrid AC and DC distribution grids.
文摘The Floating nuclear power plant grid is composed of power generation,in-station power supply and external power delivery.To ensure the safety of the nuclear island,the in-station system adopts a special power supply mode,while the external power supply needs to be adapted to different types of external systems.Because of frequent single phase-ground faults and various fault forms,the fault line selection protection should be accurate,sensitive and adaptive.This paper presents a fault line selection method in cooperation with multi-mode grounding control.Based on the maximum united energy entropy ratio(MUEER),the optimal wavelet basis function and decomposition scale are adaptively chosen,while the fault line is selected by wavelet transform modulus maxima(WTMM).For high-impedance faults(HIFs),to enlarge the fault feature,the system grounding mode can be switched by the multi-mode grounding control.Based on the characteristic of HIFs,the fault line can be selected by comparing phase differences of zero-sequence current mutation and fault phase voltage mutation before and after the fault.Simulation results using MATLAB/Simulink show the effectiveness of the proposed method in solving the protection problems.