Calculation of Eddy Current Loss and Short-circuit Force in SSZ11-50000/110 Power Transformer
1
作者 Yan Li Bo Zhang +2 位作者 Longnv Li Tongxun Yang Ning Wang 《Energy and Power Engineering》 2013年第4期1105-1108,共4页
The ?method is used in this paper to calculate the leakage magnetic field of SSZ11-50000/110 Power transformer, and by which the structures’ influences to the main leakage flux are analyzed. Through the combination o... The ?method is used in this paper to calculate the leakage magnetic field of SSZ11-50000/110 Power transformer, and by which the structures’ influences to the main leakage flux are analyzed. Through the combination of the product and TEAM Problem 21B, the surface impedance method shows its great advantage in the calculation of eddy current loss. 展开更多
关键词 Power transformer FINITE Element short-circuit FORCE EDDY current LOSS Surface IMPEDANCE Method
下载PDF
Research on Numerical Simulation of 3D Leakage Magnetic Field and Short-circuit Impedance of Axial Dual-low-voltage Split-winding Transformer
2
作者 Yan Li Longnv Li +1 位作者 Yongteng Jing Fangxu Han 《Energy and Power Engineering》 2013年第4期1093-1096,共4页
It is difficult to accurately calculate the short-circuit impedance, due to the complexity of axial dual-low-voltage split-winding transformer winding structure. In this paper, firstly, the leakage magnetic field and ... It is difficult to accurately calculate the short-circuit impedance, due to the complexity of axial dual-low-voltage split-winding transformer winding structure. In this paper, firstly, the leakage magnetic field and short-circuit impedance model of axial dual-low-voltage split-winding transformer is established, and then the 2D and 3D leakage magnetic field are analyzed. Secondly, the short-circuit impedance and split parallel branch current distribution in different working conditions are calculated, which is based on field-circuit coupled method. At last, effectiveness and feasibility of the proposed model is verified by comparison between experiment, analysis and simulation. The results showed that the 3D analysis method is a better approach to calculate the short-circuit impedance, since its analytical value is more closer to the experimental value compared with the 2D analysis results, the finite element method calculation error is less than 2%, while the leakage flux method maximum error is 7.2%. 展开更多
关键词 Split-winding transformer short-circuit Impedance Field-circuit Coupled current Distribution
下载PDF
Application of thyristor controlled phase shifting transformer excitation impedance switching control to suppress short-circuit fault current level 被引量:14
3
作者 Jun LIU Xudong HAO +3 位作者 Xu WANG Yefu CHEN Wanliang FANG Shuanbao NIU 《Journal of Modern Power Systems and Clean Energy》 SCIE EI 2018年第4期821-832,共12页
Short-circuit fault current suppression is a very important issue in modern large-interconnected power networks. Conventional short-circuit current limiters, such as superconducting fault current limiters, have to inc... Short-circuit fault current suppression is a very important issue in modern large-interconnected power networks. Conventional short-circuit current limiters, such as superconducting fault current limiters, have to increase additional equipment investments. Fast power electronics controlled flexible AC transmission system(FACTS)devices have opened a new way for suppressing the fault current levels, while maintaining their normal functionalities for steady-state and transient power system operation and control. Thyristor controlled phase shifting transformer(TCPST) is a beneficial FACTS device in modern power systems, which is capable of regulating regional powerflow. The mathematical model for TCPST under different operation modes is firstly investigated in this study. Intuitively, the phase shifting angle control can adjust the equivalent impedance of TCPST, but the effect has been demonstrated to be weak. Therefore, a novel transformer excitation impedance switching(EIS) control method, is proposed for fault current suppressing, according to the impedance characteristics of TCPST. Simulation results on IEEE 14-bus system have shown considerable current limiting characteristic of the EIS control under various fault types. Also, analysis of the timing requirement during fault interruption, overvoltage phenomenon, and ancillary mechanical support issues during EIS control is discussed,so as to implement the proposed EIS control properly for fast fault current suppression. 展开更多
关键词 Excitation impedance switching(EIS) CONTROL INTERRUPTION time sequence PHASE SHIFTING angle(PSA) CONTROL short-circuit fault current suppression Thyristorcontrolled PHASE SHIFTING transformer(TCPST)
原文传递
降低在线变压器短路事故率的若干思路 被引量:4
4
作者 邬伟民 孙亚明 董永平 《变压器》 北大核心 1999年第7期1-7,共7页
主要从运行管理的角度,介绍了变压器短路事故的严重程度。分析了影响短路电流的因素及导致短路事故的机理,提出了降低变压器短路事故的措施。
关键词 变压器 短路事故率 电力变压器 运行管理
下载PDF
Single-ended Fault Detection Scheme Using Support Vector Machine for Multi-terminal Direct Current Systems Based on Modular Multilevel Converter
5
作者 Guangyang Zhou Xiahui Zhang +2 位作者 Minxiao Han Shaahin Filizadeh Zhi Geng 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2023年第3期990-1000,共11页
This paper proposes a single-ended fault detection scheme for long transmission lines using support vector machine(SVM)for multi-terminal direct current systems based on modular multilevel converter(MMC-MTDC).The sche... This paper proposes a single-ended fault detection scheme for long transmission lines using support vector machine(SVM)for multi-terminal direct current systems based on modular multilevel converter(MMC-MTDC).The scheme overcomes existing detection difficulties in the protection of long transmission lines resulting from high grounding resistance and attenuation,and also avoids the sophisticated process of threshold value selection.The high-frequency components in the measured voltage extracted by a wavelet transform and the amplitude of the zero-mode set of the positive-sequence voltage are the inputs to a trained SVM.The output of the SVM determines the fault type.A model of a four-terminal DC power grid with overhead transmission lines is built in PSCAD/EMTDC.Simulation results of EMTDC confirm that the proposed scheme achieves 100%accuracy in detecting short-circuit faults with high resistance on long transmission lines.The proposed scheme eliminates mal-operation of DC circuit breakers when faced with power order changes or AC-side faults.Its robustness and time delay are also assessed and shown to have no perceptible effect on the speed and accuracy of the detection scheme,thus ensuring its reliability and stability. 展开更多
关键词 Fault detection short-circuit fault multi-terminal direct current systems based on modular multilevel converter support vector machine(SVM) wavelet transform
原文传递